W185074ID.00 Prequalification Package.pdf
PDF 3 MB Posted
- Attached to
- Elevated Water Tank Demolition
- Solicitation number
- RFQ-25-008
- Issued by
- Bonner County, Idaho
About this file
This document is a Statement of Qualifications (SOQ) packet for the Elevated Tank Demolition project (Project #2-37-24-1-WTR-2026-24) issued by the City of Idaho Falls Public Works Department in August 2025. The project involves the demolition of a 0.5 million gallon (MG) steel construction eight-legged elevated tank approximately 185 feet tall, located within the Idaho Falls Power campus. The scope of work includes complete tank demolition, associated feature removal, proper disposal of hazardous waste (including lead-coated tank parts), and surface restoration of pavement and other finished surfaces disturbed during the project. The project is expected to have a duration of 6 weeks after the Notice to Proceed, with an engineer's estimated project cost of less than $500,000.
The SOQ packet outlines a pre-qualification process for general/prime contractors, who must submit detailed documentation demonstrating their qualifications by August 26, 2025. Contractors must provide comprehensive information including current and previous project experience, safety records, licensing, bonding capacity, and organizational details. Only pre-qualified contractors will be permitted to bid on the project, with the City reserving the right to reject any submissions that do not meet their standards of performance, reliability, and capability. The document requires contractors to have specific experience with elevated tank demolitions, including projects involving tanks at least 100 feet tall, crane-assisted demolition, and experience in urban or space-constrained environments.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| REQUEST FOR CONTRACTOR QUALIFICATIONS.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF QUALIFICATIONS PACKET
FOR
ELEVATED TANK DEMOLITION
PROJECT #2-37-24-1-WTR-2026-24
CITY OF IDAHO FALLS
AUGUST 2025
THIS PAGE INTENTIONALLY LEFT BLANK
W185074ID.00 Table of Contents
00 01 10 - 1
TABLE OF CONTENTS
STATEMENT OF QUALIFICATIONS
00 00 00 Statement of Qualifications Informational Packet 3-6
00 45 13 Bidder’s Qualifications 7-18
00 45 13A Bidder’s Qualifications – Project Reference Form 1-4
SUPPLEMENTARY INFORMATION
EXHIBIT A: Project Location and Overview
EXHIBIT B: 1936 Elevated Tank Drawings
END OF SECTION
W185074ID.00 Table of Contents
00 01 10 - 2
W185074ID.00 Statement of Qualifications Informational Packet
00 00 00 - 3
STATEMENT OF QUALIFICATIONS
INFORMATIONAL PACKET
FOR
ELEVATED TANK DEMOLITION
PROJECT # 2-37-24-1-WTR-2026-24
FOR
CITY OF IDAHO FALLS
Pursuant to IC 67-2805, “Procurement of Public Works Construction”, the City of Idaho Falls
(OWNER), Idaho is requesting Statements of Qualifications (SOQs) from general/prime contractors who are interested in bidding on the above referenced project. Only pre-qualified contractors will be allowed to bid the project as a general/prime contractor and perform the elevated tank demolition.
DESCRIPTION OF WORK: The work consists of the demolition of the 0.5 million gallon (MG) steel construction eight-legged elevated tank, approximately 185 feet tall. The tank is located within the campus of Idaho Falls Power. The project will generally include demolition of the tank and associated features, proper disposal including hazardous waste disposal of lead-coated tank parts, as well surface restoration of pavement and other finished surfacing and above ground features that were disturbed during the project. The project has an expected duration of 6 weeks after the
Notice to Proceed. The engineer’s opinion of probable cost is presently estimated to be less than
$500,000.
Only contractors who are considered qualified as bidders as a result of this request will be allowed to complete the Tank Demolition.
All contractors interested in qualifying to bid this project are responsible for all costs incurred in preparing or responding to this request and must submit a response in the format and time identified.
SOQ Format This Statement of Qualifications Packet includes the following:
Section 00 45 13 Bidder’s Qualifications (required to be invited to submit a formal bid)
Contractors are to submit for any and all work for which they would like to qualify. Answers to the questions on these forms must be typed or neatly hand written in ink. The completed form is to be submitted as part of the SOQ. Attachments may also be included in the SOQ, but only as necessary to respond to specific questions either where an attachment is specifically required or if additional space is needed. SOQ submittals are to be signed using the Certification Pages provided.
00 00 00 - 4
Address and Marking of Qualification Packets: Refer to the Request for Qualifications.
SOQ Evaluation: Upon receipt of SOQs, the OWNER will evaluate them and determine which contractors are qualified to bid as general/prime contractor and to perform the Tank Demolition.
The following can result in a contractor being found not qualified:
1. Failure to meet the "Minimum Requirements";
2. Failure to submit any material information required;
3. Deliberate submission of false information; or,
4. Any combination of substantive factors including, but not limited to, history of failure to perform in contracts, disregard of laws and regulations, inferior quality control and safety programs, etc., which in the sole discretion of the City, do not meet the standards of fitness or reliability expected from firms wishing to bid on this project.
The OWNER reserves the right to reject any and all Qualification Submittals, to waive any informalities and irregularities in said submittals and to approve the submittals which serves the best interest of the OWNER. The OWNER will notify each applicant of their qualification status within a period not to exceed thirty (14) days from the Opening Date.
Any protest of determination of qualifications or bidding procedures will be handled in accordance with procedures delineated in IC 67-2805.
If the OWNER proceeds with bidding of the project, all firms deemed qualified by the OWNER will be invited to submit formal bids for the project as delineated in the Project Manual, which is currently under development. The Contract Documents will generally conform to the format specified by the Engineers Joint Contract Documents Committee (EJCDC) Contract Documents.
Successful applicants will be provided plans and bid documents, notified of the time, date, and place for the public opening of construction bids for the Elevated Tank Demolition Project.
The OWNER reserves the right to cancel or postpone contractor qualification for the project and overall project construction.
Questions/Clarifications
Please address questions regarding the requirements or how to submit a qualification response to:
David Richards
Water Superintendent
Telephone: (208) 612-8471
Email: drichards@idahofalls.gov
00 00 00 - 5
Bidding Requirements
Competitive bid prices for construction of the named project are important to the City. As such, contractors that are determined to be qualified to bid on this project are excluded from forming joint ventures or teams with other qualified contractors without receiving approval from the City in advance of the bid.
Public Information
SOQs may be considered a public record and, except as noted below, will be available for inspection and copying by any person after the approval of qualified applicants. The OWNER will take reasonable efforts to protect any information marked “confidential,” to the extent allowed by Idaho Public Records Law. It is understood, however, that the OWNER will have no liability for disclosure of such information. Any proprietary or otherwise sensitive information contained in or accompanying any SOQ is subject to potential disclosure.
00 00 00 - 6
W185074ID.00 Bidder’s Qualifications
00 45 13 - 7
SECTION 00 45 13 – BIDDER’S QUALIFICATIONS
THE INFORMATION SUPPLIED IN THIS DOCUMENT IS CONFIDENTIAL TO THE EXTENT
PERMITTED BY LAWS AND REGULATIONS
The City of Idaho Falls requires Bidder’s Qualifications shall be completed and submitted by contractors who would like to bid on the City of Idaho Falls, Elevated Tank Demolition, a 0.5 million gallon (MG) 185 feet tall, steel construction eight-legged elevated tank demolition project, regarding their financial ability, equipment, and experience in relation to the proposed elevated tank demolition work. Only pre-qualified contractors will be allowed to bid the project as a general/prime contractor and perform the elevated tank demolition Contractors must be qualified by the ENGINEER in order to be invited to bid on the project.
This Statement of Qualifications Form shall be completed and submitted by no later than 10:00
A.M. (Local Time) on TUESDAY, AUGUST 26, 2025 to:
Submitted to: City of Idaho Falls, Office of Public Works Department
Address: 380 Constitution Way Idaho Falls, ID 83402
Attention: Engineering Division
To qualify for this project, the prospective GENERAL CONTRACTOR must complete the following information:
1. SUBMITTED BY:
Official Name of Firm:
Address:
2. SUBMITTED TO: City of Idaho Falls
3. SUBMITTED FOR: Idaho Falls Elevated Tank Demolition
Owner: City of Idaho Falls
Project Name: City of Idaho Falls – Elevated Tank Demolition
00 45 13 - 8
TYPE OF WORK: Heavy Municipal – Elevated Water Tank
4. CONTRACTOR'S CONTACT INFORMATION
Contact Person:
Title:
Phone:
Email:
5. AFFILIATED COMPANIES:
Name:
6. TYPE OF ORGANIZATION:
SOLE PROPRIETORSHIP
Name of Owner:
Doing Business As:
Date of Organization:
00 45 13 - 9
PARTNERSHIP
Type of Partnership:
Name of General Partner(s):
CORPORATION
State of Organization:
Date of Organization:
Executive Officers:
- President:
- Vice President(s):
- Treasurer:
- Secretary:
LIMITED LIABILITY COMPANY
State of Organization:
Members:
00 45 13 - 10
JOINT VENTURE
State of Organization:
Date of Organization:
Form of Organization:
Joint Venture Managing Partner
- Name:
- Address:
Joint Venture Managing Partner
Joint Venture Managing Partner
7. LICENSING
Jurisdiction:
Type of License:
License Number:
Jurisdiction:
Type of License:
License Number:
00 45 13 - 11
8. BONDING INFORMATION
It is anticipated that the total contract price for the project will be less than $500,000. Contractor’s must have the ability to bond for this amount to be qualified.
Bonding Company:
Bonding Agent:
Contact Name:
Phone:
Aggregate Bonding Capacity:
Available Bonding Capacity as of date of this submittal:
00 45 13 - 12
9. BIDDER’S EXPERIENCE:
Current Experience:
List on Schedule A all uncompleted projects currently under contract (If Joint Venture list each participant's projects separately).
Previous Experience:
List on Schedule B the names, addresses and telephone numbers of the owners and project engineers, and completion dates and locations of at least three (3) demolitions of elevated tanks or structures, and three (3) hazardous waste projects requiring waste haul and disposal of hazardous waste including lead-coated structures, located within the United
States or Canada which have been successfully demolished by the Bidder during the last 10 years. In order to meet the experience requirements, the demolitions of elevated tanks or structures shall have been at least 100-feet tall and have been demolished with use of crane(s) to remove parts of the structure. One (1) demolition of elevated tank or structure must have been undertaken in an urban or space constrained environment. Projects with multiple qualifications may be listed. (Provide an attachment if additional space is required.)
A complete Project Reference Form (provided at the end of this section 00 45 13A) is required for all projects provided in Schedule B.
Has firm listed in Section 1 ever failed to complete a construction contract awarded to it?
YES NO
If YES, attach as an Attachment details including Project Owner's contact information.
Has any Corporate Officer, Partner, Joint Venture participant or Proprietor ever failed to complete a construction contract awarded to them in their name or when acting as a principal of another entity?
YES NO
If YES, attach as an Attachment details including Project Owner's contact information.
Are there any judgments, claims, disputes or litigation pending or outstanding involving the firm listed in Section 1 or any of its officers (or any of its partners if a partnership or any of the individual entities if a joint venture)?
YES NO
If YES, attach as an Attachment details including Project Owner's contact information.
00 45 13 - 13
Has firm listed in Section 1 had its contractor's license suspended, put on probation or revoked in any jurisdiction?
YES NO
If YES, provide the project, dates, circumstances, resolution, and/or other pertinent details on a separate page.
Has firm listed in Section 1 had a bankruptcy petition filed in its name, voluntary or involuntary?
YES NO
If YES, provide the project, dates, circumstances, resolution, and/or other pertinent details on a separate page.
Has firm listed in Section 1 had insurance terminated by a carrier due to excessive claims history and/or nonpayment of premium?
YES NO
If YES, provide the project, dates, circumstances, resolution, and/or other pertinent details on a separate page.
Has the Bidder been involved with litigation with an Owner during a construction project in the past 5 years?
YES NO
If YES, provide the project, dates, circumstances, resolution, and/or other pertinent details on a separate page.
10. SAFETY PROGRAM:
Name of Contractor's Safety Officer:
Include the following as attachments:
Provide as an Attachment Contractor's OSHA No. 500- Log & Summary of Occupational
Injuries & Illnesses for the past 5 years.
Provide as an Attachment Contractor's list of all OSHA Citations & Notifications of Penalty
(monetary or other) received within the last 5 years (indicate disposition as applicable) - IF
NONE SO STATE.
Provide as an Attachment Contractor's list of all safety citations or violations under any state all received within the last 5 years (indicate disposition as applicable) - IF NONE SO STATE.
00 45 13 - 14
I HEREBY CERTIFY THAT THE INFORMATION SUBMITTED HEREWITH, INCLUDING ANY ATTACHMENTS, IS
TRUE TO THE BEST OF MY KNOWLEDGE AND BELIEF.
NAME OF ORGANIZATION:
BY:
TITLE:
DATED:
NOTARY ATTEST:
SUBSCRIBED AND SWORN TO BEFORE ME
THIS DAY OF , 2025
NOTARY PUBLIC - STATE OF
MY COMMISSION EXPIRES:
REQUIRED ATTACHMENTS
1. Schedule A (Current Experience).
2. Schedule B (Previous Experience) with Project Reference Form for each project listed.
3. Evidence of authority for individuals listed in Section 6 to bind organization to an agreement.
4. Required safety program submittals listed in Section 11. Safety information from Subcontractors and Suppliers may be required to be submitted up to 7 days after the project bid date.
5. Additional items as pertinent.
00 45 13 - 15
SCHEDULE A
CURRENT EXPERIENCE
Project Name Owner's Contact Person Design Engineer Contract Date Type of Work Status Cost of Work
Telephone:
Name:
Company:
Telephone:
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
00 45 13 - 16
SCHEDULE B
PREVIOUS EXPERIENCE (A complete Project Reference Form is required for all projects provided in Schedule B)
Project Name Owner's Contact Person Design Engineer Contract Date Description relevant to
Bidder’s qualifications
Status Cost of Work
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
00 45 13 - 17
SCHEDULE B
PREVIOUS EXPERIENCE (A complete Project Reference Form is required for all projects provided in Schedule B)
Project Name Owner's Contact Person Design Engineer Contract Date Type of Work and Tank Size Status Cost of Work
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
Telephone:
Name:
00 45 13 - 18
THIS PAGE INTENTIONLLY LEFT BLANK
W185074ID.00 Bidder’s Qualifications – Project Reference Form
00 45 13A - 1
PROJECT REFERENCE FORM
ELEVATED TANK DEMOLITION
PROJECT # 2-37-24-1-WTR-2026-24
CITY OF IDAHO FALLS
Project Name:
Project Description:
Contractor's Project Manager:
Original Contract Value ($):
Change Order Amount ($):
Original Project Schedule (days):
Revised/Final Project Schedule (days):
Describe Change Orders (cost and schedule):
00 45 13A - 2
List the trades required for the job, the approximate percentage of total project amount associated with each trade, and the name of the subcontractor used (if applicable).
Were liquidated damages assessed or were there any claims on this project? If yes, describe amounts and details.
Owner's Contact Information (Entity, Name, Role and Phone Number):
00 45 13A - 3
Engineer's Contact Information (Entity, Name, Role and Phone Number):
00 45 13A - 4
EXHIBIT A: PROJECT LOCATION AND OVERVIEW
XXX
X X
X X
X X
X X
X X
X X
X
W
W W
W
W W
W W
W W
W W
W W
W W
W
WW
WWW
W
W
W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD SD
SD
SD
FO
FO
FO
E
E
E E
E
E
E
E E
FO
FO
FO
FO
FO
FO
FO
SD
W
DEMO
DEMO UTILITY
ABANDON
CONTRACTOR STAGING
AND WORK AREAS
LEGEND
I I I I I I I I I
X X X X X X X X X
PRELIMINARY
NOT FOR
CONSTRUCTION95% SUBMITTAL
Drawing Path and Name: A:\_V-W\Projects\ID\idaho falls\2018\w185074id.00\12 CADD\12-5 sheets\W185074ID_C-010.dwg, Plotted Date: July 28, 2025 10:28 AM By: Anthony DePaul
1 2 3 4 5 6
A
B
C
D
Engineer's Seal:
This document, and the ideas and designs incorporated herein, are Instruments of Professional Service of Consor and are not to be used, reused, or modified, in whole or in part, by any other person for any other purpose without the express written authorization of Consor.
Sub Consultant: Client / Owner: Project Title:
Sheet:
0 11/2 IF BAR DOES NOT MEASURE 1"
DRAWING IS NOT TO SCALE
Designed By:
Drawn By:
Checked By:
Approved By:
Consor Project No.:
Issued On:
CITY OF IDAHO FALLS
ELEVATED TANK DEMOLITION
W185074ID
JULY 2025
Consultant:
CIVIL
EXISTING CONDITIONS AND
DEMOLITIONS
DSN
AVD
CHK
APP
C-010
PLAN
SCALE: 1" = 20'
DEMO ELEVATED
WATER TANK
NOTES:
1. SAW CUT ASPHALT PATCH SQUARE WITH A MINIMUM CUTBACK OF 1' FROM
DEMO ITEM ITEM, PATCH PER IDAHO FALLS STANDARD DRAWING IF-303, TYPE
P, ASPHALT AND CRUSHED AGGREGATE MATERIALS PER IDAHO FALLS
STANDARD SPECIFICATIONS.
2. SALVAGE AND DELIVER THE FOLLOWING ITEMS TO THE CITY OF IDAHO FALLS,
WATER DEPARTMENT:
(3) 40-FOOT LONG LEG PIECES
(1) OLD-STYLE LIGHT BEACON AT TOP OF TANK
(1) PLAQUE LOCATED AT BASE ON TANK
(1) BOWL ACCESS HATCH AT BASE OF BOWL
3. PUBLIC ACCESS SHALL BE MAINTAINED AT ALL TIMES FOR THE PARKING
SPACES LOCATED NORTH OF THE ADMIN BUILDING.
4. PRESERVE AND PROTECT NOTED ITEMS ON SHEET. CONTRACTOR SHALL
PRESERVE AND PROTECT ALL ITEMS THAT ARE NOT SPECIFIED OR NOTED ON
SHEET FOR DEMOLITION.
5. TRUCKS FOR SALVAGE OR DEMOLITION HAUL SHALL UTILIZE THE RAILROAD
BED FOR LOADING OF MATERIALS WITH ACCESS VIA CAPITAL AVE. PROVIDE
TEMPORARY FENCING, SIGNAGE, AND TEMPORARY DETOUR ROUTE FOR THE
PROTECTION OF PEDESTRIANS ON ADJACENT WALKING TRAIL.
6. CONTRACTOR SHALL PROVIDE TEMPORARY FENCING (SHOWN AS SCHEMATIC)
TO SECURE SITE AGAINST ANY FALLING DEBRIS DURING DEMOLITION
OPERATIONS. COORDINATE WITH IFP AND CoIF FOR DAISY CHAIN OF LOCKS
FOR ACCESS.
IFP YARD
IFP GEN BUILDING SEE
NOTE 4 MAINTAIN
BUILDING ACCESS ON
WEST SIDE OF BUILDING
IFP GARAGE,
MAINTAIN
IFP ADMIN BUILDING,
SEE NOTE 4
CoIF, WELL 3
SEE NOTE 4
DEMO CONC. PEDESTALS TO A DEPTH
OF 14" BELOW GRADE AND PATCH
ASPHALT PER NOTE 1, TYP OF 8
CELL TOWER MAST,
APPROX. LOC., SEE NOTE 4
TRANSFORMER,
SEE NOTE 4
DEMO STAND PIPE AND INTERNAL
PIPING TO A DEPTH OF 14" BELOW
GRADE, FILL PIPES WITH GROUT UP TO
CoIF ABANDONMENT, AND ABANDON IN
PLACE, PATCH ASPHALT PER NOTE 1
NORTH PARKING LOT
CONC WALL,
SEE NOTE 4
APPROX
BOWL DIA
WATERLINE FOR TANK, CoIF TO
DISCONNECT PIPING AND PROVIDE
CAPS FOR ABANDONMENT AT MAIN,
COORDINATE ABANDONMENT OF
STANDPIPE PIPING WITH CoIF
MANUAL GATE,
COORDINATE DAISY
CHAIN FOR ACCESS
WITH IFP, SEE NOTE 4
AUTOMATIC GATE,
COORDINATE WITH IFP
FOR ACCESS,
SEE NOTE 4
RAILROAD BED,
SEE NOTE 5
SOLAR PANEL AND ASSOCIATED
ELECTRICAL DISTRIBUTION
APPROX. LOC., SEE NOTE 4
TEMPORARY FENCING,
SEE NOTE 6
ACCESS TO S
CAPITAL AVE
SE
E
NO
TE
PROJECT LOCATION AND OVERVIEWPRELIMINARY DOCUMENT
FOR REFERENCE ONLY
IDAHO FALLS POWER
140 S CAPITAL AVE, IDAHO FALLS, ID 83402
CoIF = CITY OF IDAHO FALLS
IFP = IDAHO FALLS POWER
EXHIBIT A
EXHIBIT B: 1936 ELEVATED TANK DRAWINGS
EXHIBIT B
| Table of Contents |
| Statement of Qualifications Informational Packet |
| Biider's Qualifications |
| Schedule A - Current Experience |
| Schedule B - Previous Experience |
| Project Reference Form |
| Exhibit A: Project Location and Overview |
| Exhibit B: 1936 Elevated Tank Drawings |
File details come from the government source that posted it. Updated .