Lifejacket_Sales_Sheet.pdf

PDF 132 KB Posted

Attached to
Elevator Modernization Project- United States Mint-Philadelphia
Solicitation number
USM-HQ-17-0007
Issued by

About this file

Life Jacket Pamphlet

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LifeJacket® Hydraulic Elevator Safety Comprehensive Protection from the Damage of Hydraulic Failure

Hydraulic elevators can malfunction, lose pressure and fall. The results can be catastrophic – personal injury, loss of life, equipment damage and legal liability.

Protect the riding public, your company and the building owners and managers you service with the LifeJacket hydraulic safety system from Adams.

The LifeJacket encircles the elevator plunger. If it senses loss of pressure or uncontrolled downward car movement, it immediately closes, bringing the elevator and passengers to a safe, controlled stop.

The LifeJacket is easily installed on hydraulic elevators of any age. There’s no reason to go another day without protection.

More Parts Delivered Faster

Adams Safety Products

She’s Upset She’s STUCK

You’re Thankful She’s STOPPED

Adams Safety Products

LifeJacket® Hydraulic Elevator Safety Comprehensive Protection from the Damage of Hydraulic Failure

United States Canada International Phone: 800-929-9247 Phone: 800-268-5392 Phone: 847-965-0700 Fax: 847-581-2949 Toronto: 416-253-6661 Fax: 847-965-3758 adams_parts@adamselevator.com Fax: 416-253-1662 adams_safety@adamselevator.com

ELEVATOR EQUIPMENT COMPANY

www.adamselevator.com 6310 W. Howard Street • Niles, IL 60714-3480 USA ©2006 Adams Elevator Equipment Company

Spread the Word About LifeJacket Every year hydraulic elevators fail and fall. Most building owners and managers are unaware of the dangers of hydraulic elevator failure and their resulting exposure to liability. LifeJacket protects against the catastrophic damage caused by a hydraulic elevator failure. As a plunger gripper, it meets the latest safety code requirements.*

Routine Maintenance Isn’t Enough Even the most skilled maintenance contractor can’t detect potential hydraulic failure during a service call. Even when tests indicate the elevator is working to required performance levels, hidden dangers such as a corroded cylinder far below ground, failing pipes or valves may subsequently trigger a loss of pressure resulting in a fall.

100% Safety – How it Works The LifeJacket installs above the cylinder head, encircling the elevator plunger. If a loss of pressure or uncontrolled downward car movement is detected, its jaws close, bringing the elevator and its passengers to a safe, controlled stop – with no damage to the plunger.

LifeJacket Protects Against:

• Cylinder failure. In-ground cylinders are susceptible to underground electrolysis that may cause dangerous levels of deterioration.

• Break in hydraulic line or failed valves. Field feedback indicates that 60% of all LifeJacket activations are actually caused by failures other than the cylinder, such as broken pipes or failed valves.

Installs easily on virtually any hydraulic elevator – old or new

Easy to test and reset – no damage to plunger

The most comprehensive protection from potential damage and liability

Don’t go another day without protection. Call Adams today 1-800-929-9247 or visit www.adamselevator.com

LifeJacket jaws in open position – normal operation.

Jaws grip plunger when activated to safely stop elevator.

*ASME A17.1a 2002 Addenda (sec. 3.17.3) states: “In the event of fluid loss or overspeed, the use of a plunger gripper is permitted as an acceptable means to bring an elevator to a safe, controlled stop.”