TABLE 1 - RCRA Wastes.docx
DOCX document 27 KB Posted
- Attached to
- Hazardous Waste Services - Statewide
- Contract number
- 505ENT-M20-HZRDSWSTSV-01
- Issued by
- Wisconsin
About this file
This document is Table 1 from RFP 28314-JM, which outlines the hazardous waste streams that must be managed under a state contract vehicle for the State of Wisconsin and cooperating entities. The table serves as a comprehensive specification for hazardous waste management services, defining the scope of materials that contractors must be capable of handling under this procurement.
The contract covers an extensive range of hazardous waste categories including RCRA wastes (ignitable, corrosive, reactive, and toxic wastes), F-listed and P&U listed wastes, FIFRA pesticides, pharmaceutical disposal services, non-RCRA gases, universal wastes, remedial action wastes, mixed radioactive waste, and other non-RCRA materials such as PCBs and asbestos. The document specifies whether state entity use is mandatory or elective for each waste category, with most RCRA wastes being mandatory while services for items like non-RCRA pharmaceuticals, compressed gases, and certain universal wastes remain elective. Universal wastes must be recycled, and the contract encompasses both routine waste disposal and specialized services such as DEA controlled substance destruction and contaminated soil remediation, providing Wisconsin state entities with comprehensive hazardous waste management capabilities.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Zone Map - Appendix B.doc | DOC document | |
| Veolia Contact List 2023.docx | DOCX document | |
| Lamp Ballast Electronic Inventory Form.pdf | ||
| State of WI Hazardous Waste Services Price Sheet 10.1.23.xlsx | XLSX spreadsheet | |
| Quick Start Guide 08.18.23.docx | DOCX document | |
| RFP 28314-JM Hazadous Waste - FINAL.rtf.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TABLE 1 – RCRA Wastes – reprinted from RFP 28314-JM
The waste streams listed in Table 1 (below), and in Section 4.17 of RFP 28314-JM, represent the hazardous wastes to be managed for State of Wisconsin (and cooperating entities) end users.
TABLE 1 – RCRA Wastes
RCRA Wastes (including but not limited to the list below)
State Entity use is Mandatory for all items listed under RCRA Wastes.
Characteristic Hazardous Wastes
| 4.17.1.1 |
| Ignitable Wastes (D001); High Total Organic Carbon (TOC) - Liquid, Solid, Gas |
Examples: Laboratory solvents (both halogenated and non-halogenated), paint-related wastes, organic solvents and oils, organic solids and semi-solids (wipes & rags contaminated with halogenated or non-halogenated organic solvents), organic liquids contaminated with PCBs, pharmaceuticals, gas cylinders, aerosol cans and non-liquids capable of causing and sustaining a fire due to friction, moisture absorption or spontaneous chemical changes.
| 4.17.1.2 |
| Ignitable Waste (D001); Low TOC (Oxidizers) - Liquid, Solid, Gas |
Examples; Wastes that consist of chemical(s) that have been identified by the US DOT as Oxidizers as defined in 49 CFR 173.127(a), water treatment, sanitizing and decontamination chemicals.
| 4.17.1.3 |
| Corrosive Wastes (D002); Acidic Liquids and Basic Liquids |
Examples; Organic and inorganic acids (pH ≤ 2.0 or as determined by corrosion testing), organic and inorganic bases (pH ≥ 12.5 or as determined by corrosion testing), gas cylinders and aerosol cans.
| 4.17.1.4 |
| Reactive Wastes (D003) - Liquid, Gas, Solid |
Examples; Unstable or deteriorated laboratory chemicals (picric acid, ethers containing peroxides), water reactive metals (sodium, lithium, and phosphorus), toxic gas emitters, cyanide and sulfide bearing wastes, materials capable of detonation or explosive reaction or forbidden and Class A and Class B explosives as defined in 49 CFR 173.52 through 173.54.
| 4.17.1.5 |
| Toxic Wastes (D004 through D043 as listed in NR 661.24(2), Table 2 and as determined by the TCLP test) - Liquid, Solid |
Examples; Inorganic solids with or without toxic metals (reagent salts, used filters or PPE, metal turnings, silica gel), surface preparation (blasting) wastes, Mercury salts/solutions, chemically contaminated items, Firing range wastes, organic & inorganic sludge material, pharmaceuticals.
| 4.17.1.6 |
| Wastes with two or more EPA waste codes; Ignitable D001 with toxic constituent, Corrosive D002 with a toxic constituent |
Examples; Corrosive wastes with dissolved toxic metals, organic liquid waste mixtures with toxic components (organic and inorganic).
Listed Hazardous Wastes
| 4.17.1.7 |
| F-Listed Wastes (F001 through F043) - Liquid, Solid, Gas |
Examples; Spent halogenated and non-halogenated solvents (including degreasing), Organic solids and semi-solids (wipes & rags) contaminated with halogenated or non-halogenated F–listed organic solvents, dioxin and dioxin containing wastes (e.g., F027), contaminated or mixed chlorofluorocarbons (Freon) or other hazardous waste refrigerants.
| 4.17.1.8 |
| P & U Listed Wastes - Liquid, Solid, Gas |
Examples; Commercial chemical products that appear on the toxic or acute hazardous waste lists in NR661.33 (5) and (6), including off-specification species, container residues and spills thereof, excess laboratory chemicals and pesticides.
FIFRA and Related Wastes (including but not limited to the list below)
State Entity Use (Mandatory or Elective) as noted:
| 4.17.1.9 |
| Non-RCRA Pesticides (Mandatory) |
Gaseous pesticides-gas cylinders, lecture bottles & pressurized canisters (Mandatory)
Pesticide sludge (Mandatory)
Pesticide contaminated soil (Elective)
Pharmaceutical Disposal Services (including but not limited to the list below)
State Entity Use (Mandatory or Elective) as noted:
| 4.17.1.10 |
| DEA controlled substances (Elective) |
RCRA Pharmaceuticals (Mandatory, but see RCRA Controlled Substances below )
Non-RCRA Pharmaceuticals (Elective)
DEA Controlled Substances/RCRA Pharmaceuticals (Elective, if the material is surrendered to a sworn law enforcement officer)
Non-RCRA Gases (including but not limited to the list below)
State Entity use is Elective for all items listed under Non-RCRA Gases.
| 4.17.1.11 |
| Compressed gas cylinders |
Lecture bottles
Pressurized canisters
Liquefied gas
Universal Wastes (Shall be Recycled)
State Entity Use (Mandatory or Elective) as noted:
| 4.17.1.12 |
| Mercury containing equipment - switches, laboratory instruments. (Mandatory) |
Lamps (Mandatory) PCB Ballasts (Mandatory) Non-PCB Ballasts (Elective)
Antifreeze (Elective)
Batteries: rechargeable and non-rechargeable (Elective)
Regulated Remedial Action and Investigation Wastes
State Entity use is Mandatory except for asbestos-containing material.
| 4.17.1.13 |
| Offsite management of RCRA or TSCA regulated PCB -contaminated soil, water & debris |
Mixed Waste
State Entity use is Elective for all Mixed Wastes.
| 4.17.1.14 |
| Low-level radioactive waste with hazardous waste code(s). |
Other Non-RCRA Wastes (listed below)
State Entity use is Elective except for PCB's.
| 4.17.1.15 |
| PCBs and PCB contaminated materials and waste (Mandatory) |
Combustible liquids
Other liquid wastes (e.g., maintenance chemicals, paints, contaminated water, cleaners)
Laboratory chemicals
Aerosols Petroleum contaminated soil, sludge and absorbents for bioremediation Refrigeration gases Asbestos Remediation and investigation wastes (e.g., soil, water, debris, sludge and absorbents) Infectious wastes Used oil, oil filters and fuel filters, petroleum contaminated absorbents Waste waters (e.g., oil/water mixture, chiller water) Non-hazardous dry paint waste
File details come from the government source that posted it. Updated .