Statement_of_Work.pdf

PDF 517 KB Posted

Attached to
REPLACE SAN CRISTOBAL EXTERIOR LIGHTS AT SAN JUAN
Solicitation number
140P5421R0040
Issued by

About this file

This statement of work describes a project to replace exterior lights at Castillo San Cristobal in San Juan National Historic Site. The National Park Service seeks to replace 74 in-ground uplights, 12 pedestal-mounted floodlights, and 17 wall-mounted luminaires with energy efficient, color-tunable LED fixtures. Optional items include 36 portable outdoor light fixtures, 6 carrying cases, 2 wireless controllers, 2 remote controls, and 36 extra batteries. Specifications require the LED lights to provide uniform illumination of at least 3 footcandles, minimize light spillage, and allow color changing. The period of performance is 120 days from notice to proceed. The contractor must dispose of old fixtures and measure illuminance on site. Delivery requirements include product data sheets, photometric analyses, and warranty information. Quality assurance procedures must be developed and work shall follow all OSHA standards.

View the file

Other files

File Type Posted
Past_Performance_Questionnaire.pdf PDF
SAJU_242489_Exterior_Lights.pdf PDF
Sol_140P5421R0040.pdf PDF
Wage_Determination.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SAN JUAN NATIONAL HISTORIC SITE

SAN JUAN, PUERTO RICO

STATEMENT OF WORK:

Replace Exterior Lights Castillo San

Cristobal

October 30, 2020

NATIONAL PARK SERVICE

SOUTHEAST REGION

SOUTH MAJOR ACQUISITION BUYING OFFICE

SAJU, Replace San Cristobal Exterior Ligths and Fixtures

STATEMENT OF WORK (SOW)

SOW Format

1. Background

2. Objectives

3. Place of performance

4. Period of performance

5. Scope

6. Tasks

7. Delivery

8. Government-Furnished Property (GFP)

9. Security Considerations

10. Travel

11. Special Material Requirements

12. Other Unique Requirements and Considerations

13. Quality Assurance Requirement

1. BACKGROUND

The existing exterior lights were installed to provide security for San Cristobal. Their operation has a major impact on the park’s electricity bills. The park is seeking to reduce the cost of operating external lights by replacing them with long-life energy-efficient LED luminaires.

2. OBJECTIVES:

Replace existing exterior lights with energy efficient lighting fixtures, while minimizing light spillage and enabling color changing for special events.

Purpose of exterior lighting is for decoration and security.

3. PLACE OF PERFORMANCE:

El Castillo San Cristobal is a large masonry Fort on the northeast side of San Juan Island in Puerto Rico.

Work days and hours: 7:00am to 3:00pm Monday through Friday, excluding Federal Holidays.

Access to jobsite and electrical panels will be gained through the Contracting Officer Representative (COR) and/or park maintenance staff.

4. PERIOD OF PERFORMANCE:

Period of performance is 120 calendar days from issuance of Notice to Proceed.

5. SCOPE:

This project is to remove existing exterior lighting and replace with long-life energy-efficient LED luminaires. This lighting project shall have a similar appearance to the lighting at San Felipe del Morro (El Morro), which is under construction and scheduled to be completed by November 30, 2019. (See Figure 1 Below for reference)

Contractor is responsible for the following items:

BASE BID ITEMS:

1. (74) in-ground, flush-mounted color-tunable uplights, (See “A” and “F”, per drawings)

2. (12) pedestal-mounted color-tunable floodlights (See “B”, per drawings)

3. (5) wall-mounted luminaires or area lamps. (See “C and D”, per drawings)

4. (11) wall-mounted luminaires. Light fixtures labeled “E” will be replaced in-kind using

LED bulbs (See “E” per drawings)

5. (12) inside-wall luminaries or area lamps. (See “G” per drawings)

OPTIONAL BID ITEM:

6. Portable Exterior Lights with:

A. (36) temporary outdoor light fixtures with removable batteries (see Optional bid Item

“A” Highlights and Specifications) B. (6) road cases (see Optional bid Item “A” Highlights and Specifications) C. (2) wireless controllers for light fixtures (see Optional bid Item “B” Highlights and

Specifications) D. (2) remote controls (see Optional bid Item “C” Highlights and Specifications) E. (36) extra batteries for light fixtures

Figure 1: Aerial View of Castillo San Cristobal exterior light fixtures locations.

*See Appendix A PDF file for example photos of actually installed fixtures.

Add control system for the new color-tunable luminaires; existing electrical wiring to luminaires shall be retained, and no new control wiring may be run to luminaires.

Install new concrete support bases for each pedestal-mounted floodlight per manufacturer recommendations. Match the height of the existing lighting.

Properly dispose of existing light fixtures and concrete bases and any other debris or trash generated on this project.

6. SPECIFICATIONS FOR ALL LUMINAIRES:

Light housings shall be metal, either stainless steel or aluminum. Lighting shall sustain wind loads from hurricanes. All fasteners (bolts, anchors, washers, etc.) shall be stainless steel.

Luminaires shall be tamper-proof and listed or certified for wet locations by a U.S. Occupational Safety Health Administration (OSHA) Nationally Recognized Testing Laboratory (NRTL).

Luminaires shall accept 60 Hz single-phase 120 V electric service and operate normally with input voltage fluctuations consistent with NEMA SSL 1-2010.

Except where noted, luminaire shall have light output of electronically tunable color, and be capable of both of the following operating modes:

A. Warm white light, with a nominal correlated color temperature (CCT) value that is ≤ 3000 K, measured CCT and Duv values within ANSI C78.377-2017 tolerances for the nominal CCT value, and color rendering index (CRI) of ≥ 65.

B. Tunable (i.e., selectable or changeable) color. Luminaire shall be capable of producing any of a wide variety of saturated colors (e.g., blue or pink) for holidays and other special occasions.

Control of color-tunable luminaires must be wireless (e.g., Bluetooth or wireless DMX) or utilize existing electrical wiring (i.e., powerline carrier). No new wiring may be run to luminaires.

Luminaire light output shall not exhibit flicker exceeding the low-risk limits in Figure 18 of IEEE Standard 1789-2015. Specifically, the quotient of percent flicker (i.e., modulation depth) and flicker frequency shall be < 0.08 at flicker frequencies ≥ 90 Hz, and the quotient percent flicker / flicker frequency shall be < 0.025 at flicker frequencies < 90 Hz.

Combined illumination from in-ground and pedestal-mounted luminaires shall provide an average illuminance of ≥ 3.0 footcandles (fc, or lumens per square foot) on each of the seven illuminated wall segments when operating in warm-white mode, measured perpendicular to wall surface (i.e., with back of typical illuminance meter pressed to wall), with average-to-minimum uniformity ratio of ≤ 3:1. Calculation grid points shall be spaced 4 feet apart on each 32-foot height wall sloped 15 degrees away from luminaires (8 horizontal rows of points spaced 4 feet apart horizontally, centered on each wall segment). Luminaire locations are as shown in plan; in-ground luminaires are spaced approximately 18 feet apart and setback 2 feet from wall, on average.

Luminaires shall be selected with appropriate optical control to minimize light spillage.

Lumen maintenance for warm white light mode at 60,000 hours operation shall be ≥ 85% of initial, supported by IES TM-21 calculations based on IES LM-80 data and in-situ temperature measurement (ISTMT) testing, in accordance with the Design Lights Consortium methodology.

Luminaires shall have a minimum warranty of 5 years.

The new lighting will be differentiated from the old (historic lighting) and will be compatible with the historic materials, features, size, scale and proportion, and massing to protect the integrity of the property and its environment.

7. SPECIFICATIONS FOR IN-GROUND LUMINAIRES:

Luminaire shall allow for replacement of LED light engine (or LED light source and driver) in luminaire without excavation.

Luminaire shall have a minimum ingress protection (IP) rating of 68, as defined in IEC 60529.

Color-tunable luminaire input power shall not exceed 60 W in any mode.

If luminaire intensity distribution is circular (i.e., X° beam) or oval (i.e., X° by Y° beam) in cross-section, luminaire must have minimum 10° internal tilt capability, and minimum initial light output is 700 lumens. If the intensity distribution is instead of asymmetric design to wash or graze walls (i.e., does not exhibit quadrilateral symmetry) and lumens in quarter-sphere oriented toward wall are at least four times (4x) lumens in quarter-sphere oriented away from wall, then no tilt mechanism is required and minimum initial light output is 350 lumens. Resulting accent on wall shall have a natural “scallop” appearance with gradual fade from point of maximum illuminance, demonstrated via computer-generated grayscale rendering subject to COR approval.

Luminaire must be flush with ground surface (cannot protrude above) and rated to support the weight of industrial riding lawnmowers.

In-ground luminaires shall be Kim Lighting, model LED RGBW in-grade adjustable accent light, narrow flood optic, LTV81SS-NF-24RGBWUV or COR approved equivalent.

8. SPECIFICATIONS FOR PEDESTAL-MOUNTED LUMINAIRES:

Luminaire shall have a minimum IP rating of 66.

In warm-white mode, color-tunable luminaire shall have minimum initial light output of 6300 lumens; input power shall not exceed 220 W in any mode.

Pedestal mounted luminaire shall be LED RGBW Floodlight, Horizontal Flood Optic Kim Lighting, model KFL3-33l-75-RGBWW-HF or COR approved equal.

9. SPECIFICATIONS FOR WALL-MOUNTED LUMINAIRES:

Luminaire shall have a minimum IP rating of 66.

Luminaire shall operate in warm-white mode only, and have maximum input power of 220 W.

Luminaire shall be mounted at existing location approximately 10 feet above grade. Coordinate with COR to determine necessary hardware for attaching to historic structure.

Luminaires shall provide a combined average horizontal illuminance of ≥ 3.0 fc at grade, with average-to-minimum uniformity ratio of ≤ 4:1 (excluding points not in luminaire line-of-sight), measured on a grid with points spaced 10 feet apart.

The wall mount luminaires shall be LED Floodlight, Kim Lighting, Scarab model EL700S3/12L3KUV/BL – AGS74BL – JW/BL-P or COR approved equal.

10. PORTABLE, OUTDOOR RATE LIGHT FIXTURES FOR EVENTS WITH ROAD CASE:

These portable LED light fixtures shall come in cases capable of carrying 6 light fixtures, 6 batteries, POWER CORD, a hand remote for individual use. Carrying case has to be capable of charging the batteries. Carrying case should come as a bundle and include 6 light fixtures, 6 batteries, and a remote controller for individual use.

36 Portable Light Fixture and Fixtures Carrying Cases need to have the following qualities/highlights and specifications:

• 100% TRUE wireless up light system complete with 6 Freedom Flex H4 IP pars, 6 Flex batteries and a charging road case

• 100% TRUE wireless, battery-operated, hex-color (RGBAW+UV) LED Par with built-in D-Fi transceiver

• Swappable battery packs ensures the fixture is always ready to go

• Charging road case simultaneously charges and holds 6 additional batteries (sold separately)

• Temporary outdoor-rated robust housing repels water, snow, dirt, and sand for all-weather applications

• Multiple wireless triggering and control options via the FlareCON Air and the FlareCON app

• Works in master/slave with all Freedom Pars

• Shine light where it is needed using the built-in adjustable kickstand

• Convenient, wireless non-DMX control using the IRC-6 remote

• Achieve smooth LED fading with built-in dimming curves

• Compact and lightweight design easily fits inside sticks of TRUSST

• DMX Channels: 6, 8 or 12

• Max Unobstructed Distance: 600 ft (182.88 m)

• Light Source: 4 LEDs (hex-color RGBAW + UV) 10 W, (2 A), 50,000 hours life expectancy.

• Strobe Rate: 0 to 30 Hz

• PWM Frequency: 1.2 KHz

• Beam Angle: 23°

• Field Angle: 34°

• Recharge Time: 6 hours

• Illuminance: 2,163 lux @ 2 m

• IP Rating: IP54

• Weight: 96 lb (44 kg)

• Size: 20.95 x 19.22 x 11.81 in (532 x 488 x 300 mm)

• Approvals: CE, FCC

• Maximum Run Time (all on): up to 8 hours

• Maximum Run Time (single color): up to 20 hours

• Startup Temperature: 32 °F to 122 °F (0 °C to 50 °C)

• Operating Temperature: -4 °F to 140 °F (-20 °C to 60 °C)

• Bracket Mounting Hole: M12

• Road Case Compatible Fixtures: Freedom Flex H4 IP

• Road Case Wheel Size: 3 in (76.2 mm)

• Road Case Weight: 51.4 lb (23.3 kg)

• Road Case Size: 60.31 x 58.58 x 11.73 in (1532 x 1488 x 300 mm)

• The portable outdoor rated light for events shall be equal to the FREEDOM FLEX H4 IP X6 bundle or COR approved equal.

Two (2) Wireless controller: wireless controller need to have the following qualities/highlights and specifications:

• FlareCON™ App is now available for download: Android | iOS

• Compact, easy-to-use Wi-Fi receiver and wireless D-Fi transmitter in a single unit

• Compatible with Android™ operating system and Mac OS® on both smartphones and tablets

• Output can be used in wireless D-Fi and/or wired DMX protocols

• Wirelessly synchronize an unlimited number of D-Fi-ready fixtures and receivers simultaneously

• Built-in options include manual or automatic channel selection

• Simple navigation and text readout using the OLED digital display

• Mounting options include built-in hook and loop fastener strap, keyhole mounting holes, M10 and M12 threaded holes for direct mounting to truss

• Fully FCC/RTTE compliant

• DMX Channels: 512

• DMX Connectors: 3-pin XLR

• Input Voltage: 9 VDC, 500 mA (external power supply: 100 to 240 VAC, 50/60 Hz)

• Power and Current: 4 W, 0.1 A @ 120 V, 60 Hz

4 W, 0.1 A @ 230 V, 50 Hz

• Weight: 1.2 lb (0.6 kg)

• Size: 5.59 x 3.58 x 1.81 in (142 x 91 x 46 mm)

• Approvals: CE, FCC

• The wireless controller shall be the FLARECON AIR or COR approved equal.

Two (2) additional hand controller: remote controller need to have the following qualities/highlights and specifications:

• Wireless remote control for all CHAUVET Freedom series and IRC products

• Allows you to wirelessly select color, intensity, strobe rate and more

• Provides instant access to pre-programmed light shows

• Manually set individual color percentages to achieve the exact color without a DMX controller

• Input Voltage: 3 VDC lithium battery (CR2025)

• Weight: 0.7 oz (20 g) https://play.google.com/store/apps/details?id=com.chauvet.FlareCON&hl=en https://itunes.apple.com/us/app/flarecon/id890903885?ls=1&mt=8

• Size: 3.9 x 1.8 x 0.3 in (100 x 47 x 7 mm)

• Approvals: CE

• The hand controller shall be the IRC-6 or COR approved equal.

Two (2) additional Batteries: additional batteries need to have the following qualities/highlights and specifications

• Tool-less design offers quick and easy battery replacement

• Premium lithium ion battery pack, for use with any Freedom Flex unit

• Weight: 2.2 lb (1 kg)

• Size: 5.0x 2.0x 5.22 in (127.83 x 53.16 x 132.62 mm)

• Battery Type: Li-ion

• Battery Capacity: 11 Ah

• Battery Voltage: 11.1 VDC

• Quantity of Cells: 15

• Rechargeable: Yes

• Coin/Button Battery: No

• Watt Hours: 122.1 Wh

• Lithium Content: 131.6 g

• The batteries shall be Freedom Flex Battery or COR approved equivalent.

11. SITE WORK:

All work shall be completed in compliance with OSHA standards and regulations. All electrical work shall be completed by a licensed electrician or under the direct supervision of a licensed electrician.

All junction boxes shall be potted using an insulating and sealing polymeric potting compound with fast crosslinking at room temperature, sticky, adhesive, re-enterable, and suitable for filling. The potting compound shall be suitable for anticorrosion protection, non-toxic, and safe.

In suitable cases, it shall give a degree of protection of IP 68.

For fixtures flush with the earth, notify COR three work days prior to ground disturbance.

Coordinate shutting off electrical service to fixtures with COR prior to demolition and installation of fixtures.

Coordinate with park to shut off power to buried light fixtures prior to ground disturbance.

Uncover fixtures using hand tools, minimizing the volume of ground disturbance around the fixture. All soils shall remain on site. Installation may require some gravel to allow for drainage away from the buried fixture. Fixtures shall be installed per manufacturer’s recommendations.

Remove existing fixture; install, wire and connect new fixture. All conduit, wiring, and boxes shall be sealed to prevent water entry.

Coordinate with COR to determine suitable location for color-tuning control system equipment.

Except where noted otherwise, new fixtures shall be placed in the same location as existing fixtures. Luminaires shall be properly aimed upon installation, then secured to prevent tampering of the light’s aim. Fixtures shall be aimed for uniformity of illumination and to minimize light spillage over the top of the walls or other items to which they’re aimed.

Upon completion of installation, measure warm-white mode illuminance on representative portion of wall segment to be selected by COR post-installation. Measurement grid shall consist of 8 horizontal rows 4 feet apart, with 4 points 4 feet apart in each row, centered on the wall between in-ground uplights. The illuminance meter shall be calibrated by an ILAC MRA Signatory-accredited laboratory over a range of illuminance values inclusive of 0.3 fc and 30 fc using CIE Standard Illuminant A (incandescent). Provide illuminance measurement data to COR prior to final inspection.

12. DELIVERY:

Provide the following to CO or his/her representative for approval.

Pre-Construction Submittals:

• Letter designating Project Superintendent

• Proof of insurance

• Project Schedule

• Schedule of Values

• Signed SF-1413’s for each sub-contractor

• Safety Plan

• Electrician’s license

Pre-Mobilization Submittals:

• For each luminaire type (in-ground, pedestal-mount, wall-mount) o Luminaire spec/cut/data sheets, with project-specific configuration(s) and complete model number (catalog ordering information) indicated o Data sheets for LED light sources, LED drivers, and any surge-protection devices o Instructions for luminaire installation, operation, and maintenance o OSHA NRTL luminaire safety certification and file number indicating compliance with UL o Luminaire warranty o IES LM-79 test report and corresponding LM-63 luminous intensity data file from an ILAC

MRA Signatory-accredited laboratory (luminaire in warm-white mode) o IES LM-80 test report(s), In-Situ Temperature Measurement Test (ISTMT) report, and IES

TM-21 spreadsheet calculations per DesignLights Consortium requirements for Option 1 (https://www.designlights.org/solid-state-lighting/submit-a-product/lumen-maintenance/) with luminaire operating in warm-white mode

• Computer-generated point-by-point photometric analysis of maintained light levels, using a light loss factor (LLF) of 0.85 and lumen output in warm-white mode.

• Computer-generated grayscale rendering for each of the 7 illuminated wall segments

• Site plan drawn to scale with table/schedule indicating complete model numbers of luminaires to be used at each location (e.g., input power and optic/beam may vary), complete with aiming angles (horizontal orientation and vertical tilt) and any available locations not needed/utilized

• For each color-tunable luminaire type, a table of CIE 1931 (x, y) or CIE 1976 (u', v') chromaticity diagram coordinates defining the polygon containing the set of distinct colors that can be produced via the control system

• For each color-tuning control system, complete datasheets and instructions/manuals/warranty

Close-Out Submittals

• Post-installation illuminance (footcandle) measurement data

• Operation and maintenance information for each type of fixture installed

• Certified payrolls

• Release of Claims

Spare parts:

• Any spare parts sent with fixtures shall be turned over to COR at project completion https://www.designlights.org/solid-state-lighting/submit-a-product/lumen-maintenance/

• (2) spare wall-mount luminaire (letter “E” type)

• (2) spare pedestal-mount floodlight luminaires (letter “B” type)

• (6) spare in-ground uplight luminaires (letter “A” type)

• (2) spare in-ground uplight luminaire replaceable LED light engines

• (2) spare inside-wall luminarie

13. GOVERNMENT-FURNISHED PROPERTY, MATERIAL, EQUIPMENT, OR

INFORMATION (GFP, GFM, GFE, OR GFI):

Schematic of light fixture locations around Castillo San Cristobal, attached.

14. SECURITY:

Contractor is responsible for securing any equipment, parts, tools, etc. left on site. NPS cannot be held liable for damage or theft to items retained on NPS property.

COR will provide Contractor with access to building spaces necessary to complete the required tasks.

15. TRAVEL:

Travel fees related to this contract shall be included in the contractor’s bid proposal. Do not include travel costs as a separate line item. Contractor is not authorized to bill the government for travel as a unique expenditure.

16. SPECIAL MATERIAL REQUIREMENTS:

Materials shall be corrosion resistant.

17. OTHER UNIQUE REQUIREMENTS:

None.

18. QUALITY ASSURANCE REQUIREMENT:

The contractor shall develop and maintain a quality program to ensure services are performed in accordance with commonly accepted commercial practices. The contractor shall develop and implement procedures to identify, prevent, and ensure non-recurrence of defective services. As a minimum the contractor shall develop quality control procedures addressing the critical areas identified in this statement of work. The government will periodically evaluate the contractor’s performance in accordance with the statement of work.

APPENDICES

Appendix A: San Cristobal Exterior Light Locations Appendix B: San Cristobal Elevation Drawings

STATEMENT OF WORK:
NATIONAL PARK SERVICE SOUTHEAST REGION
STATEMENT OF WORK (SOW)
1. BACKGROUND
2. OBJECTIVES:
3. PLACE OF PERFORMANCE:
4. PERIOD OF PERFORMANCE:
5. SCOPE:
6. SPECIFICATIONS FOR ALL LUMINAIRES:
7. SPECIFICATIONS FOR IN-GROUND LUMINAIRES:
Luminaire shall allow for replacement of LED light engine (or LED light source and driver) in
luminaire without excavation.
Luminaire shall have a minimum ingress protection (IP) rating of 68, as defined in IEC 60529.
Color-tunable luminaire input power shall not exceed 60 W in any mode.
If luminaire intensity distribution is circular (i.e., X beam) or oval (i.e., X by Y beam) in cross-section, luminaire must have minimum 10 internal tilt capability, and minimum initial light output is 700 lumens. If the intensity distribution is ...
Luminaire must be flush with ground surface (cannot protrude above) and rated to support the weight of industrial riding lawnmowers.
In-ground luminaires shall be Kim Lighting, model LED RGBW in-grade adjustable accent light, narrow flood optic, LTV81SS-NF-24RGBWUV or COR approved equivalent.
8. SPECIFICATIONS FOR PEDESTAL-MOUNTED LUMINAIRES:
9. SPECIFICATIONS FOR WALL-MOUNTED LUMINAIRES:
Luminaire shall have a minimum IP rating of 66.
Luminaire shall operate in warm-white mode only, and have maximum input power of 220 W.
Luminaire shall be mounted at existing location approximately 10 feet above grade. Coordinate with COR to determine necessary hardware for attaching to historic structure.
Luminaires shall provide a combined average horizontal illuminance of ≥ 3.0 fc at grade, with average-to-minimum uniformity ratio of ≤ 4:1 (excluding points not in luminaire line-of-sight), measured on a grid with points spaced 10 feet apart.
10. PORTABLE, OUTDOOR RATE LIGHT FIXTURES FOR EVENTS WITH ROAD CASE:
11. SITE WORK:
12. DELIVERY:
13. GOVERNMENT-FURNISHED PROPERTY, MATERIAL, EQUIPMENT, OR INFORMATION (GFP, GFM, GFE, OR GFI):
14. SECURITY:
15. TRAVEL:
16. SPECIAL MATERIAL REQUIREMENTS:
17. OTHER UNIQUE REQUIREMENTS:
18. QUALITY ASSURANCE REQUIREMENT:

File details come from the government source that posted it. Updated .