Statement of WorD Diver Hull Clean Inspect Zinc Anodes Renewal CHARLES DAVID JR..pdf
PDF 214 KB Posted
- Attached to
- 52000QR260001531 USCGC CHARLES DAVID JR. Diver Hull Clean, Inspect & Zinc Anodes Renewal
- Solicitation number
- 52000QR260001531
About this file
This Statement of Work (SOW) details underwater hull maintenance services for the USCGC CHARLES DAVID JR. (WPC 1107) located in Key West, FL. The contractor will perform diver hull cleaning, inspection, and zinc anode renewal during a maintenance period from 05-07 JAN 2026, with specific tasks including cleaning underwater body surfaces and appendages, removing marine growth and debris, polishing PORT and STBD propellers, and renewing government-furnished zinc anode components. The work requires submitting video recordings and photographs before and after cleaning, ensuring no damage to existing underwater coating systems, and following Coast Guard maintenance procedure cards B10015.D and B10018.D.
The SOW includes a comprehensive list of government-furnished zinc anode and hardware items with National Stock Numbers (NSNs), part numbers, quantities, and estimated unit costs. Key components include stern tube anodes, sea chest grate anodes, propeller zinc plates, and various associated screws and nuts. The work will be completed pier-side, with specific requirements for protective measures, cleaning techniques (such as using only soft hand-held brushes for transducers), and adherence to referenced Coast Guard technical drawings for vessel-specific details.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Smart Matrix SAP CM FFP.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
CGC CHARLES DAVID JR. (WPC 1107)
Diver Hull Clean, Inspect & Zinc Anodes Renewal
FSMS PR# 52000PR260001531
Description of Services:
Contractor travel to CGC CHARLES DAVID JR. homeport in Key West, FL to perform cleaning and inspection of underwater hull and running gear (appendages), polish PORT and STBD propellers, renewal of government-furnished zinc anodes/hardware, provide inspection report, before/after video and photographs IAW MPC's B10015.D and B10018.D.
Cutters Maintenance Period:
Complete during the period of 05-07 JAN 2026 (scheduling to be arranged with cutter EPO)
Cutter Homeport Location:
USCGC CHARLES DAVID JR. (WPC 1107)
100 Trumbo Point Road Key West, FL 33040-6650
Cutter Contact Info:
EPO: MKC Clayton W. Wendelgass Email: Clayton.W.Wendelgass@uscg.mil
PH: (727) 415-2040
Requisitioner Contact Info:
SFLC-PBPL-APM: Roderick Stroud Email: Roderick.A.Stroud@uscg.mil
PH: (571) 607-6951
IPP Approver Contact Info:
SFLC-PBPL-Section Chief: LT Alexandra Lombardi Email: Alexandra.P.Lombardi@uscg.mil
PH: (781) 715-5683
mailto:Clayton.W.Wendelgass@uscg.mil mailto:Roderick.A.Stroud@uscg.mil mailto:Alexandra.P.Lombardi@uscg.mil
U/W Body (Waterborne), Diver Hull Clean, Inspect, & Zinc Anodes Renewal
1. Scope
1.1 Intent. This work item describes the requirements for the Contractor to clean and inspect the vessel’s underwater (U/W) body, and to renew bolt-on zinc anodes, while the vessel is moored pier side.
1.2 Government-furnished property.
MTI ITEM DESCRIPTION NSN/PN QTY ESTIMATED
COST
($/UNIT)
N Anode, Stern Tube NSN: 5340-01-644-5483
PN: Z0020202H3
28 ea. 14.20
N Nut, Self-Locking NSN: 5310-01-508-5774
PN: 90715A145
3 pkg.
*25 in pkg.
8.39
N Anode, Sea Chest Grate NSN: 5340-01-647-6179
PN: GA-4
4 ea. 26.29
N Screw, Prop Zinc Plate NSN: 5305-01-634-0210
PN: 950756
8 ea. 19.22
N Screw, Sea Chest Grate Anode
NSN: 5305-01-619-7182
PN: 93190A634
1 pkg.
*5 in pkg.
8.49
N Screw Cap, Stern Tube Covers
NSN: 5305-01-616-1107
PN: 90585A626
42 ea. 2.68
N Zinc Plate, Propeller NSN: 5340-01-627-8941
PN: 950733
2 ea. 1,087.87
N Anode, Bow Thruster, Gear Case, Bolt On
NSN: 5342-12-356-1870
PN: 1081226
1 ea. 65.46
N Anode, Bow Thruster, Tunnel, Bolt On
NSN: 5340-20-012-6334
PN: CM2000Z
12 ea. 32.83
2. REFERENCES
COAST GUARD DRAWINGS
Coast Guard Drawing 154 WPC 111-301, Rev B, Shell Expansion Coast Guard Drawing 154 WPC 161-301, Rev C, Skegs and Stern Tubes Support Structures Coast Guard Drawing 154 WPC 245-304, Rev B, Propeller Plans and Data Six Blade Propeller Coast Guard Drawing 154 WPC 562-201, Rev A, Rudder Details Coast Guard Drawing 154 WPC 565-201, Rev -, Fin Stabilizer System A & D Coast Guard Drawing 154 WPC 568-201, Rev B, Bow Thruster System A & D Coast Guard Drawing 154 WPC 997-302, Rev -, Docking Plan
COAST GUARD PUBLICATIONS
Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements Surface Forces Logistics Center Maintenance Procedure Card B10015.D (MPC B10015.D), 10/31/24, Underwater Body and Appendages Inspect/Clean (Diver) Surface Forces Logistics Center Maintenance Procedure Card B10018.D (MPC B10018.D), 4/30/25, Underwater Zinc Anode Replace
OTHER REFERENCES
None
3. REQUIREMENTS
3.1 General.
3.1.1 CIR. None.
3.1.2 Tech Rep. None.
3.1.3 Protective measures. The Contractor must furnish and install all protective measures in accordance with SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection).
3.1.4 Interferences. The Contractor must handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences).
3.2 Requirements. The Contractor must:
3.2.1 Video recording/photographs. Submit video highlights and photographs of all underwater body surfaces and appendages (e.g. bow thruster, propellers, rudders, fin stabilizers, transducers, sea chests, heavily fouled hull areas, etc.) before and after cleaning.
3.2.2 Clean/inspect. Clean the underwater body surfaces and appendages free of all marine growth, debris, and all other surface contaminants, to include inspections in accordance with MPC B10015.D.
Polish the surfaces of both PORT and STBD propellers. Ensure all transducer surfaces are cleaned with only soft hand held brushes, without the use of power attachments. Ensure that existing underwater body coating system or non-coated surfaces do not incur any damage during cleaning process. Refer to Coast Guard drawings listed in Section 2.
3.2.3 Renew anodes. Renew Government-furnished components listed below paragraph 1.2. in accordance with MPC B10018.D.
4. NOTES
This section is not applicable to this work item.
U/W Body (Waterborne), Diver Hull Clean, Inspect, & Zinc Anodes Renewal
File details come from the government source that posted it. Updated .