PGC_02850_tech_data.docx

DOCX document 28 KB Posted

Attached to
Marine Corps All Weather Coats Federal contract opportunity
Solicitation number
SPE1C1-13-R-0003
Issued by
Defense Logistics Agency Troop Support Clothing and Textiles

About this file

Techncial Information

View the file

Other files for this federal contract opportunity

Other files attached to Marine Corps All Weather Coats, newest first.
File Type Posted
SPE1C113R00030002.PDF PDF
SPE1C113R00030006.PDF PDF
SPE1C113R00030003.PDF PDF
SPE1C113R00030007.PDF PDF
SPE1C113R00030005.PDF PDF
SPE1C113R00030004.PDF PDF
SPE1C113R00030001.PDF PDF
SF1449_SPE1C113R0003 1 .pdf PDF
CR_PD_03-08.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COAT, ALL WEATHER, MAN'S PEWTER SHADE 2246

DOUBLE BREASTED FRONT WITH BELT.

ADDITIONAL INFORMATION FOR CR PD 03-08:

PATTERN DATE: 04 DECEMBER 2003

STANDARD SAMPLE FOR CLOTH, POPLIN, POLYESTER AND

COTTON (WATER REPELLENT), MARINE CORPS PEWTER

2246 CONFORMING TO A-A-50531, IS AVAILABLE ON

ROLL NO. 1208-06. THIS SAMPLE SHALL SHOW COLOR-

FASTNESS IN ACCORDANCE WITH THE TABLE BELOW.

CHARACTERISTICS REQUIREMENT TEST METHOD

LAUNDERING (MIN) EQUAL TO

STANDARD AATCC 61 3A

AFTER 3 CYCLES GRADE 4 AATCC 61 3A

PERSPIRATION (MIN) GRADE 4 AATCC 15 1/

CROCKING (MIN) GRADE 2.5 AATCC 8

LIGHT (MIN) GRADE 4 AATCC 16 OPT A

INTERIM CHANGES TO PD-03-08:

PAGE 11, TABLE IV -COAT FINISHED MEASUREMENTS,

DELETE TABLE IV & INSERT NEW TABLE AS FOLLOWS:

TABLE IV COAT FINISHED MEASUREMENTS

SIZE

. 30------32------34------36------38------40

ALL LENGTHS CHEST (1/) TOLERANCE +/- 3/4

. 39 41 43 45 47 49

SIZE

. 42------44------46------48------50------52

ALL LENGTHS CHEST (CONTINUED)

. 51 53 55 57 59 61

SIZE

. 30------32------34------36------38------40

BACK LENGTH (2/) TOLERENCE +/- 1/2

XS-- 40-3/4 41 41-1/4 41-1/2 41-3/4

S 42-1/2 42-3/4 43 43-1/4 43-1/2 43-3/4 R 44-1/2 44-3/4 45 45-1/4 45-1/2 45-3/4 L -- 46-3/4 47 47-1/4 47-1/2 47-3/4

XL-- -- 49-1/2 49-3/4 50 50-1/4

SIZE

. 42------44------46------48------50------52

BACK LENGTH (CONTINUED)

XS42 -- -- -- -- --

S 44 44-1/4 44-1/2 44-3/4 45 45-1/4 R 46 46-1/4 46-1/2 46-3/4 47 47-1/4 L 48 48-1/4 48-1/2 48-3/4 49 49-1/4

XL50-1/2 50-3/4 51 51-1/4 -- --

SIZE

. 30------32------34------36------38------40

SLEEVE LENGTH (/3) TOLERANCE +/- 1/2

XS-- 16 16 16 16 16

S 17 17 17 17 17 17 R 18 18 18 18 18 18 L -- 19 19 19 19 19

XL-- 20-1/2 20-1/2 20-1/2 20-1/2 20-1/2

SIZE

. 42------44------46------48------50------52

SLEEVE LENGTH (CONTINUED)

XS16 -- -- -- -- --

S 17 17 17 17 17 17 R 18 18 18 18 18 18 L 19 19 19 19 19 19

XL20-1/2 20-1/2 20-1/2 20-1/2 -- --

SIZE

. 30------32------34------36------38------40

BELT LENGTH (/4) TOLERANCE +/-3/4

. 40 42 44 46 48 50

SIZE

. 42------44------46------48------50------52

BELT LENGTH (CONTINUED)

. 52 54 56 58 60 62

ADDITIONAL INTERIM CHANGES TO CR/PD 03-08

PAGE 1, SCHEDULE OF SIZES, DELETE ENTIRELY AND

SUBSTITUTE THE FOLLOWING:

"XSHORT SHORT REG LONG XLONG

--- 30 30 --- --- 32 32 32 32 --- 34 34 34 34 34 36 36 36 36 36 38 38 38 38 38 40 40 40 40 40 42 42 42 42 42 --- 44 44 44 44 --- 46 46 46 46 --- 48 48 48 48 --- 50 50 50 --- --- 52 52 52 ---

PAGE 2 PARAGRAPH 3.1 DESCRIPTION, LINE 5

AFTER "5" ADD "THE MATERIAL FOR THE

SLEEVE LINING SHALL BE TAFFETA AS SPEC-

IFIED IN PARAGRAPH 3.3.2.2.)

LINE 5, DELETE "1/4" AND SUBSTITUTE "3/8".

PAGE 2, PARAGRAPH 3.1.2, BELT LOOP PLACEMENT

LINE 1, AFTER "FINISHING" DELETE "1/2" AND

SUBSTITUTE "2-1/2".

PAGE 2, PARA. 3.1.2a SHOULDER STRAPS, DELETE

PARAGRAPH IN ITS ENTIRETY AND SUBSTITUTE THE

FOLLOWING PARAGRAPH: "3.1.2a SHOULDER STRAPS.

THE OVEREDGED STRAIGHT END OF SHOULDER STRAP

SHALL BE SEWN TO THE COAT WITH A 3/16 INCH SEAM,

THEN FOLD STRAP TO THE FINISHED POSITION AND TOP

STITCH 1/4 INCH FROM THE FOLDED EDGE. THE

FINISHED SHOULDER STRAPS SHALL BE CENTERED ALONG

THE SHOULDER SEAM AND THE POINTED END SHALL

FINISH EVEN TO 1/2 INCH FROM THE COLLAR SETTING

SEAM. THE SHOULDER STRAPS SHALL FINISH SMOOTH

AND FLAT WITHOUT DISTORTION. THE SHOULDER STRAP

TOPSTITCHING SHALL FOLLOW THE TOP STITCHING LINE

OF THE FRONT SLEEVE SEAMS."

PAGE 2, PARAGRAPH 3.1.5, REMOVABLE LINER,

LINE 1, DELETE "SET IN SLEEVES" AND

SUBSTITUTE "1/2 RAGLAND SLEEVES".

LINE 3, AFTER ACCOMODATE A" DELETE "27"

AND SUBSTITUTE "24"

PAGE 2, PARAGRAPH 3.1.5.1 DELETE ENTIRELY

PAGE 3, PARAGRAPH 3.2.2. BUTTONHOLES, LINE 4,

AFTER "ONE ON THE RIGHT FRONT" INSERT "IN

HORIZONTAL ALIGNMENT WITH TOP BUTTON ON RIGHT

FRONT" AND AFTER "ONE ON EACH LAPEL" INSERT

"AND THE CUT OPENING OF BUTTONHOLES SHALL BE

POSITIONED 3/4 INCH FROM EDGE OF COAT."

PAGE 3, PARAGRAPH 3.2.2, BUTTONHOLES, LINE 5

AFTER "SQUARE-BAR TYPE" ADD "WORKED OVER

GIMP". AT END OF THE PARAGRAPH ADD:

"THERE SHALL BE TWO 3/4 INCH CUT, SQUARE BAR

TYPE BUTTONHOLES, ONE CENTERED ON THE BELT

FASTENER 3/8 INCH FROM THE END AND ONE

CENTERED ON THE RIGHT BACK VENT AS PER

MARK ON PATTERN

THE LAPEL BUTTONHOLES SHALL BE 3/4 INCH FROM

THE EDGE AND 1-1/2 INCHES DOWN FROM THE TOP

PAGE 3, PARAGRAPH 3.2.3 BUTTONS

LINE 2, DELETE "18" AND SUBSTITUTE "45"

PAGE 3, PARAGRAPH 3.2.3, BUTTONS: AFTER "THE COAT SHALL HAVE THREE 24 LIGNE BUTTONS" DELETE "ONE BUTTON SHALL BE SEWN ON EACH SLEEVE LINING TO CORRESPOND WITH THE LOOPS ON THE REMOVABLE LINER'S SLEEVE BOTTOM AND ONE SHALL BE POSITIONED ON THE BELT FASTENER" AND INSERT "ONE BUTTON SHALL BE SEWN ON EACH SLEEVE LINING TO CORRESPOND WITH THE LOOPS ON THE REMOVABLE LINER'S SLEEVE BOTTOM AND ONE ON THE LEFT BACK VENT TO CORRESPOND TO THE BUTTONHOLE. THE COAT SHALL HAVE NINE 18 LIGNE BUTTONS; EIGHT ATTACHED TO THE 45 LIGNE BUTTONS ON THE COAT FRONT AND ONE POSITIONED ON THE BELT."

PAGE 3, AFTER PARAGRAPH 3.2.3 BUTTONS, INSERT

NEW PARAGRAPH AS FOLLOWS:"3.2.3.1 LAPEL BUTTON

PLACEMENT. THE TOP RIGHT LAPEL BUTTON SHALL

BE POSITIONED SO THAT THE LEFT COAT FRONT LAYS

SMOOTH AND FLAT WITHOUT DISTORTION AND THE

NECK OPENING SHALL BE 2 TO 2-1/2 INCHES BETWEEN

COLLARSTAND JOINING SEAM AND COLLARSTAND JOINING

SEAM ACROSS FRONT OF COAT."

PAGE 6, PARAGRAPH 3.3.2.4, LINE 2 AFTER

"COMBED COTTON" INSERT "OR STAPLE RAYON".

LINE 9: DELETE "2.5" AND SUBSTITUTE "1.5"

PAGE 6, PARAGRAPH 3.3.3, LINE 1 DELETE "1/4"

AND SUBSTITUTE "3/8".

PAGE 8, TABLE II, DELETE "SLEEVE LINER AND

BELT" AND SUBSTITUTE "SLEEVE LINER AND BACK

VENT".

DELETE "STAY BUTTONS AND SUBSTITUTE "STAY

BUTTONS AND BELT) AND UNDER "TOTAL QUANTITY"

DELETE "6" AND SUBSTITUTE "7"

PAGE 8, PARAGRAPH 3.4.9 DELETE ENTIRELY AND

SUBSITUTE: "3.4.10 SLIDE FASTENER. THE

SLIDE FASTENER FOR THE COAT AND THE REMOV-

ABLE LINER SHALL BE A SEPARATING, NON-REVER-

SIBLE, RIGHT-HAND, LIGHT SIZE WITH AN ALUMINUM

OR BRASS CHAIN, SHORT TAB PULL. THE LENGTHS OF

THE SLIDE FASTENERS SHALL CONFORM TO THE SIZE

COAT WITH A MINIMUM LENGTH.OF 70 INCHES. THE

COLOR OF THE TAPE SHALL BE A GOOD MATCH TO THE

BASIC MATERIAL AND SHALL BE 7/16 OR 9/16 INCH

WIDE. THE ENDS OF THE SLIDE FASTENER SHALL

BE EQUIDISTANT FROM THE BOTTOME EDGE OF COAT.

PAGE 10, PARA.3.5 LABELS, ADD NEW PARAGRAPH

"3.5.4 DLA TROOP SUPPORT EXCLUSIVE LABEL: EACH COAT

SHALL HAVE THE DLA TROOP SUPPORT EXCLUSIVE LABEL SEWN

TO THE RIGHT INSIDE FRONT FACING ABOVE THE

SIZE/INSTRUCTION LABELS.THE LABEL SHALL

APPROXIMATELY 2 INCHES WIDE AND BE SEWN

ON ALL FOUR SIDES."

PAGE 10, TABLE III, LIST OF PETTERN PARTS, DELETE "BACK VENT FACING" AND "POCKET FACING, CORD" AND INSERT "NECK FACING" AND "NECK FACING, FUSIBLE".

PAGE 12, TABLE V - LINER FINISHED MEASUREMENTS,

DELETE TABLE V AND INSERT NEW TABLE AS FOLLOWS:

TABLE V LINER FINISHED MEASUREMENTS

ALL LENGTHS CHEST (1/) TOLERANCE +/- 3/4

SIZE

. 30------32------34------36------38------40 . 31 33 35 37 39 41

ALL LENGTHS CHEST (CONTINUED)

SIZE

. 42------44------46------48------50------52 . 43 45 47 49 51 53

. BACK LENGTH (2/) TOLERENCE +/- 1/2

SIZE

. 30------32------34------36------38------40

XS-- 33 33-1/4 33-1/2 33-3/4 34

S 34-3/4 35 35-1/4 35-1/2 35-3/4 36 R 36-3/4 37 37-1/4 37-1/2 37-3/4 38 L - 39 39-1/4 39-1/2 39-3/4 40

XL-- -- 41-3/4 42 42-1/4 42-1/2

. BACK LENGTH (CONTINUED)

SIZE

. 42------44------46------48------50------52

XS34-1/4 -- -- -- -- --

S 36-1/4 36-1/2 36-3/4 37 37-1/4 37-1/2 R 38-1/4 38-1/2 38-3/4 39 39-1/4 39-1/2 L 40-1/4 40-1/2 40-3/4 41 41-1/4 41 1/2

XL42-3/4 43 43-1/4 43-1/2 -- --

SLEEVE LENGTH (/3) TOLERANCE +/- 1/2

SIZE

. 30------32------34------36------38------40

XS-- 14-1/2 14-1/2 14-1/2 14-1/2 14-1/2

S 15-1/2 15-1/2 15-1/2 15-1/2 15-1/2 15-1/2 R 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 L -- 17-1/2 17-1/2 17-1/2 17-1/2 17-1/2

XL-- -- 18-1/2 18-1/2 18-1/2 18-1/2

SLEEVE LENGTH (CONTINUED)

SIZE

. 42------44------46------48------50------52

XS14-1/2 -- -- -- -- --

S 15-1/2 15-1/2 15-1/2 15-1/2 15-1/2 15-1/2 R 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 16-1/2 L 17-1/2 17-1/2 17-1/2 17-1/2 17-1/2 17-1/2

XL18-1/2 18-1/2 18-1/2 18-1/2 -- --

PAGE 16, PARAGRAPH 7.2.2 ASTM TEST METHODS

ADD "D-256 STANDARD TEST METHOD FOR IMPACT RE-

SISTANCE OF PLASTICS AND ELECTRICAL INSULATING

MATERIALS".

PACKAGING AND MARKING INSTRUCTIONS:

TEN (10) ALL WEATHER COATS ONE SIZE ONLY SHALL

BE PACKED IN A SNUG FITTING FIBERBOARD SHIPPING

CONTAINER CONFORMING TO ASTM-D5118, TYPE CF,

STYLE RSC,GRADE 275, VARIETY SW, CLASS DOMESTIC

WITH A DW LINER. THE DIMENSIONS OF THE CONTAINER

SHALL APPROXIMATE 20-L X 16-W X 24-L. METHOD OF

CLOSURE SHALL BE IN ACCORDANCE WITH ASTM-D-1974,

2A2, FIGURE 1 OR AS AND ALTERNATE 2B6 OR 2B7-

FIGURE 3.

AQL'S FOR COMMERCIAL ITEM DESCRIPTIONS

END ITEM DIMENSIONAL 2.5

VISUAL 4.0

ACCEPTABILITY OF LOTS WILL BE DETERMINED BY THE

USE OF SAMPLING PROCEDURES AND TABLES FOR

INSPECTION BY ATTRIBUTES, ANSI/AQSC Z1.4,

GENERAL INSPECTION LEVEL 2".

(Ref. W2850)

NOTE: AS AN ALTERNATE A SW BOX WITH A

DW LINER IS AUTHORIZED.

SIGNIFICANT NOTE - "PALLETIZATION IS REQUIRED FOR THESE SUPPLIES".

NOTE: THE FOLLOWING APPLIES TO ALL NON-MANUFACTURED WOOD PACKAGING MATERIALS:

"All Wood Packaging Material (WPM) acquired by DOD must meet requirements of International Standards for Phytosanitary Measures (ISPM) 15, "Guidelines for Regulating Wood Packaging Materials in International Trade." DOD shipments inside and outside of the United States must meet ISPM 15 whenever WPM is used to ship DOD cargo, or when wood is being acquired by DLA for future use as packaging material. WPM is defined as wood pallets, skids, load boards, pallet collars, wooden boxes, reels, dunnage, crates, frame and cleats. Packaging materials exempt from the requirements are materials that have undergone a manufacturing process, such as corrugated fiberboard, plywood, particleboard, veneer, and oriented strand board (OSD). All WPM shall comply with one of the following official quality control programs:

Heat Treatment (HT) or Kiln Dried Heat Treatment (KD HT) in accordance with American Lumber Standard Committee, Incorporated (ALSC) Wood Packaging Material Program and WPM Enforcement Regulations (see http://www.alsc.org/; or

All WPM shall include certification/quality markings in accordance with the ALSC or NWPCA standards, as applicable. Markings shall be placed in an unobstructed area that will be readily visible to inspectors. Pallet markings shall be applied to the stringer or block on diagonally opposite sides of the pallet and be contrasting and clearly visible.

All containers shall be marked on a side other than the top or bottom, contrasting and clearly visible. All dunnage used in configuring and/or securing the load shall also comply with ISPM 15 and be marked with an ASLC approved DUNNAGE stamp. Failure to comply with the requirements of this restriction may result in refusal, destruction, or treatment of materials at the point of entry. The Agency reserves the right to recoup from the Contractor any remediation costs incurred by the Government."

PALLET SHALL BE 4 WAY ENTRY, WINGED TYPE. PALLETIZED LOAD DIMENSIONS SHALL NOT EXCEED 43 INCHES IN LENGTH, 52 INCHES IN WIDTH, AND 54 INCHES IN HEIGHT (INCLUDING THE PALLET).

THE PALLETIZED LOAD SHALL BE BONDED USING APPROVED COMMERCIAL BONDING MATERIALS. THE USE OF METAL BANDING, IN SECURING BOXES TO PALLETS, IS DISCOURAGED. PALLET LOADS SHALL CONTAIN THE SAME NUMBER OF CARTONS, OF IDENTICAL QUANTITIES, OF ONE NSN, TO THE MAXIMUM EXTENT POSSIBLE.

PALLET LOADS CONTAINING MORE THAN ONE NSN SHALL BE CLEARLY MARKED TO LIST ALL THE NSN'S CONTAINED IN THE LOAD. NO CARTON SHALL HAVE MORE THAN ONE NSN. AT THE END OF A SIZE RUN, NO MORE THAN ONE CARTON PER NSN MAY BE SHORT OR OVER THE SPECIFIED QUANTITY. SAID CARTON SHALL BE CLEARLY MARKED "SHORT" OR "OVER".

MIL-STD-147 IS REFERENCED FOR PALLETIZED LOADS.

IN ADDITION TO REQUIREMENTS SPECIFIED ABOVE THE FOLLOWING CLAUSE ALSO APPLIES:

52.247-9012 - REQUIREMENTS FOR TREATEMENT OF WOOD PACKAGING MATERIALS (WPM) - (JULY 2006)

THE GOVERNMENT ASSIGNED UNIVERSAL PRODUCT

CODE (UPC) MUST BE PLACED ON ALL SHIPPING

TGI DATA:

SIGNIFICANT NOTE - "PALLETIZATION IS REQUIRED FOR THESE SUPPLIES".

NOTE: THE FOLLOWING APPLIES TO ALL NON-MANUFACTURED WOOD PACKAGING MATERIALS:

"All Wood Packaging Material (WPM) acquired by DOD must meet requirements of International Standards for Phytosanitary Measures (ISPM) 15, "Guidelines for Regulating Wood Packaging Materials in International Trade." DOD shipments inside and outside of the United States must meet ISPM 15 whenever WPM is used to ship DOD cargo, or when wood is being acquired by DLA for future use as packaging material. WPM is defined as wood pallets, skids, load boards, pallet collars, wooden boxes, reels, dunnage, crates, frame and cleats. Packaging materials exempt from the requirements are materials that have undergone a manufacturing process, such as corrugated fiberboard, plywood, particleboard, veneer, and oriented strand board (OSD). All WPM shall comply with one of the following official quality control programs:

Heat Treatment (HT) or Kiln Dried Heat Treatment (KD HT) in accordance with American Lumber Standard Committee, Incorporated (ALSC) Wood Packaging Material Program and WPM Enforcement Regulations (see http://www.alsc.org/; or

All WPM shall include certification/quality markings in accordance with the ALSC or NWPCA standards, as applicable. Markings shall be placed in an unobstructed area that will be readily visible to inspectors. Pallet markings shall be applied to the stringer or block on diagonally opposite sides of the pallet and be contrasting and clearly visible.

All containers shall be marked on a side other than the top or bottom, contrasting and clearly visible. All dunnage used in configuring and/or securing the load shall also comply with ISPM 15 and be marked with an ASLC approved DUNNAGE stamp. Failure to comply with the requirements of this restriction may result in refusal, destruction, or treatment of materials at the point of entry. The Agency reserves the right to recoup from the Contractor any remediation costs incurred by the Government."

PALLET SHALL BE 4 WAY ENTRY, WINGED TYPE. PALLETIZED LOAD DIMENSIONS SHALL NOT EXCEED 43 INCHES IN LENGTH, 52 INCHES IN WIDTH, AND 54 INCHES IN HEIGHT (INCLUDING THE PALLET).

THE PALLETIZED LOAD SHALL BE BONDED USING APPROVED COMMERCIAL BONDING MATERIALS. THE USE OF METAL BANDING, IN SECURING BOXES TO PALLETS, IS DISCOURAGED. PALLET LOADS SHALL CONTAIN THE SAME NUMBER OF CARTONS, OF IDENTICAL QUANTITIES, OF ONE NSN, TO THE MAXIMUM EXTENT POSSIBLE.

PALLET LOADS CONTAINING MORE THAN ONE NSN SHALL BE CLEARLY MARKED TO LIST ALL THE NSN'S CONTAINED IN THE LOAD. NO CARTON SHALL HAVE MORE THAN ONE NSN. AT THE END OF A SIZE RUN, NO MORE THAN ONE CARTON PER NSN MAY BE SHORT OR OVER THE SPECIFIED QUANTITY. SAID CARTON SHALL BE CLEARLY MARKED "SHORT" OR "OVER".

MIL-STD-147 IS REFERENCED FOR PALLETIZED LOADS.

IN ADDITION TO REQUIREMENTS SPECIFIED ABOVE THE FOLLOWING CLAUSE ALSO APPLIES:

52.247-9012 - REQUIREMENTS FOR TREATEMENT OF WOOD PACKAGING MATERIALS (WPM) - (JULY 2006)

52.215-9017 List of Documents, Exhibits, and other Attachments (Apr 2008) - DLAD

(a) This solicitation/award consists of the following documents, exibits, and other attachments:

(1) DSCPM 4155.3, Quality Systems Requirements, November 3, 1997. LOT NUMBERING REQUIRED.

(2) DLAD 5025.30, Defense Logistics Agency One Book, Quality Management Programs Process Chapter, Dated October 31, 2003.

52.246-11 Higher-Level Contract Quality Requirement (Feb 1999) ANSI/ISO/ASQ Q9001-2008(excluding para 7.3) or equivalent.

Certification or registration of a contractor's quality system or program is not required by DoD if ISO or ANSI/ASQ standards are used.

52.209-4, 52.209-9P01, WHEN 52.210-9P06 IS NOT INCLUDED, INSERT THE FOLLOWING: "IF THE EXAMINATION INDICATES ONE OF THE FOLLOWING: WHICHEVER IS APPLICABLE:

(1) NO DIMENSIONAL DEFECT IS FOUND AND NO MORE THAN 10% OF THE UNITS EXAMINED ARE FOUND TO CONTAIN MAJOR OR MINOR "A" DEFECTS, OR

(2) NO DIMENSIONAL DEFECT OR SELECTED DEFECT IS FOUND NOR MORE THAN 10% OF UNITS EXAMINED ARE FOUND TO CONTAIN 3 OR 2 POINT DEFECTS, OR

(3) WHEN THE CLASSIFICATION OF DEFECTS CONTAINS ONLY MAJOR OR MINOR DEFECTS OR ONE CLASS OF DEFECTS ONLY, NO DIMENSIONAL DEFECT IS FOUND NOR MORE THAN 10% OF THE UNITS EXAMINED ARE FOUND TO CONTAIN A DEFECT.

52.209-9019 (I09C25), REQUESTS FOR WAIVER OF FIRST ARTICLE TESTING REQUIREMENTS (SEP 2008) - DLAD

GOVERNMENT LABORATORY TESTING OF COMPONENTS FOR ACCEPTANCE PURPOSE.

52.246-9P04 SHADE EVALUATION OF CONTRACTOR FURNISHED MATERIALS:

SHADE SAMPLING IS APPLICABLE

The color of the test specimen shall match the standard sample viewed using AATCC Evaluation Procedure 9, Option A, with sources simulating artificial daylight D75 illuminant with a color temperature of 7500 (+/- 200)°K, with illumination of 100 (+/- 20) foot candles, and shall be a good match to the standard sample under incandescent lamplight at 2856 (+/- 200)°K.

ALL SAMPLES/SWATCHES SUBMITTED FOR TESTING UNDER THE NEW UNIVERSAL CAMOUFLAGE SHALL BE SENT FOR GOVERNMENT TESTING TO THE ADDRESSES NOTED BELOW.

FOR SHADE TESTING: THE COMPLETED DD FORM 1222 AND THE SWATCHES SHALL BE FORWARDED TO:

DLA Product Testing Center Analytical 700 Robbins Avenue Philadelphia, PA 19111

ATTN: BLDG 5D

EMAIL: jamie.hieber@dla.mil

PHONE: 215-737-3265

FOR PHYSICAL (NON-SHADE) TESTING: IN ACCORDANCE WITH CLAUSE 52.246P44, THE CONTRACTOR'S APPROVED QUALIFIED LABORATORY WILL BE REQUIRED TO FORWARD A COMPLETED TEST REPORT FOR EACH LOT OF COMPONENTS TO THE ADDRESS BELOW. THE QAR WILL FORWARD THE COMPLETED DD FORM 1222. SAMPLES FOR PHYSICAL TESTING WILL ONLY BE FORWARDED UPON REQUEST TO:

DLA Product Testing Center Analytical 700 Robbins Avenue Philadelphia, PA 19111

ATTN: BLDG 5D

EMAIL: joseph.jaworski@dla.mil

PHONE: 215-737-3246

THE USE OF ELECTRONIC SUBMISSION OF DD FORM 1222 IS AUTHORIZED.

52.210-C002 - APPROVED FINISH(ES) OR TREATMENTS(S).

MANDATORY USE OF STATISTICAL PROCESS CONTROLS

I. GENERAL REQUIREMENTS:

A. THE OFFEROR AGREES TO MANAGE AND IMPROVE PROCESS PERFORMANCE THROUGH THE EVALUATION OF THE QUALITY OF THE PRODUCT AT THE PRIME CONTRACTOR AND/OR SUBCONTRACTOR FACILITIES, USING STATISTICAL PROCESS CONTROL (SPC) TECHNIQUES.

B. MINIMUM CRITERIA ARE ESTABLISHED IN THE AMERICAN SOCIETY OF QUALITY CONTROL (ASQC) STANDARDS B.1, B.2 AND B.3 (FORMERLY THE ANSI STANDARDS Z1.A, Z1.2 AND Z1.3). ALTERNATE SPC TECHNIQUES, SUCH AS SHORT RUN METHODS ARE ALSO ALLOWED WHERE APPLICABLE.

C. THIS QUALITY ASSURANCE PROVISION (QAP) APPLIES TO ALL WORK PERFORMED AT THE PRIME AND/OR SUBCONTRACTOR FACILITIES.

D. EXCLUSION OF SPC PLAN SUBMISSION: OFFERORS WHO CONSIDER THEMSELVES ELIGIBLE FOR EXCLUSION OF THE SPC PLAN SUBMISSION BASED ON SATISFACTORY UTILIZATION OF A PREVIOUSLY APPROVED SPC PLAN FOR THE IDENTICAL OR SIMILAR SUPPLIES ARE TO SUBMIT A WRITTEN REQUEST FOR EXCLUSION (RFE) TO THE PROCURING ACTIVITY.

ADDITIONAL INFORMATION FOR ASL:

THE ACCEPTABLE SUPPLIER LISTING (ASL) AND QUALIFIED LABORATORY LISTING (QLL) ARE NO LONGER VALID DOCUMENTS AND WILL NOT BE PUBLISHED IN THE FUTURE. THE POINT OF CONTACT FOR QUESTIONS PERTAINING TO LABORATORIES AND SUPPLIERS IS THE PROCUREMENT BUYER, INDICATED IN THE SOLICITATION OR CONTRACT. QUESTIONS SHOULD BE PROVIDED IN WRITING TO THE DESIGNATED BUYER.

CLAUSE 52.246-9P44 IDENTIFICATION OF QUALIFIED LABORATORY AND SOURCE SAMPLING APPLIES.

THE FIRST ARTICLE SHALL BE 50 UNITS EXAMINED AT THE CONTRACTOR'S PLANT FOR VISUAL AND DIMENSIONAL CONFORMANCE IN ACCORDANCE WITH THOSE PARAS. CONTAINED IN SECTION 4 OF THE END ITEM SPECIFICATION ENTITLED "END ITEM VISUAL EXAMINATION" (OR "VISUAL EXAMINATION", AS APPLICABLE) AND "END ITEM DIMENSIONAL EXAMINATION" (OR "DIMENSIONAL EXAMINATION" OR "EXAMINATION OF FINISHED MEASUREMENTS", AS APPLICABLE) WITH THE EXCEPTION THAT ALL 50 UNITS WILL BE VISUALLY EXAMINED AND THE SAMPLE SIZE FOR DIMENSIONAL EXAMINATION SHALL BE 8: OR, WHEN SECTION 4 OF THE END ITEM SPECIFICATION CITES A MILITARY STANDARD PROVISION FOR EVALUATING QUALITY, THE VISUAL AND DIMENSIONAL EXAMINATION SHALL BE MADE IN ACCORDANCE WITH THOSE PARAS. OF THE MIL-STD ENTITLED "END ITEM EXAMINATION" AND "DIMENSIONAL EXAMINATION" WITH THE EXCEPTIONS NOTED ABOVE.

ADD THIS PARA TO 52.209-4

52.215-9017 (J15C02), LIST OF DOCUMENTS, EXHIBITS, AND OTHER ATTACHMENTS

(APR 2008) - DLAD

(a) This solicitation/award consists of the following documents, exhibits, and other attachments:

(1) DSCPM 4155.3, QUALITY SYSTEMS REQUIREMENTS, NOVEMBER 3, 1997.

INSPECTION AT SOURCE/ACCEPTANCE AT SOURCE

REVIEW OF THIS ITEM HAS DETERMINED THAT THE SPECIFICATIONS, STANDARDS, PRODUCT DESCRIPTIONS OR OTHER TECHNICAL DATA APPLICABLE TO THIS PROCUREMENT ACTION DO NOT REQUIRE THE USE

OF CLASS I OZONE DEPLETING SUBSTANCES (ODS) OR ODC(S).

52.246-9031 (E46C11), SHADE EVALUATION (APR 2008) - DLAD.

100% SHADE SWATCHING IS APPLICABLE.

The color of the test specimen shall match the standard sample viewed using AATCC Evaluation Procedure 9, Option A, with sources simulating artificial daylight D75 illuminant with a color temperature of 7500 (+/- 200)°K, with illumination of 100 (+/- 20) foot candles, and shall be a good match to the standard sample under incandescent lamplight at 2856 (+/- 200)°K.

52.246-15 CERTIFICATE OF CONFORMANCE

ADDITIONAL INFORMATION FOR COMMERCIAL AQL'S:

AQL'S FOR COMMERCIAL ITEM DESCRIPTIONS (CID'S):

VISUAL - GENERAL INSPECTION LEVEL II, AQL - 1.0

DIMENSIONAL - SPECIAL INSPECTION LEVEL S-2, AQL - 2.5

ACCEPTABILITY OF LOTS WILL BE DETERMINED BY THE USE

OF "SAMPLING PROCEDURES AND TABLES FOR INSPECTION BY ATTRIBUTES", ANSI/ASQC Z1.4

TECHNICAL HISTORY/WS DATA:

THE PGC/NSN FOR THIS ITEM HAS BEEN REVIEWED IN ACCORDANCE

WITH DATA CLEANSING TEMPLATE, AND IS SUITABLE FOR

TRANSFER TO BSM PHASE 2 AT TIME OF REVIEW.

File details come from the government source that posted it. Updated .