This document is a technical drawing, specifically a roof plan for HVAC piping in Area 'D6' of a federal facility. The drawing includes details on the layout of the HVAC equipment, condensate drains, piping, and associated requirements such as maintaining manufacturer clearances, providing p-traps, and adding heat tracing.
The related federal contract opportunity is for the B46 Rooftop HVAC Insulation and Cladding project at the Defense Supply Center Richmond (DSCR) facility. This is a construction solicitation issued as an RFP under Simplified Acquisition Procedures. The contract will be firm-fixed price with a 180-day period of performance. The NAICS code is 238220 (Plumbing, Heating, and Air Conditioning Contractors) with a $19M small business size standard. A site visit is scheduled for August 28, 2024, and quotes are due on September 6, 2024. The award will be made to the lowest priced, technically acceptable offeror.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| MP-121.pdf | ||
| Addendum to RFP - Offer Requirements.pdf | ||
| Wage Determination.pdf | ||
| Tab 2 - SOW - B46 Rooftop HVAC Insulation and Cladding.pdf | ||
| SP470324R0033.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
J
J
KEY PLAN
NO SCALE
'B6' 'D6'
49x30 OA
DUCT TO
AHU-4
9TYP
TYP
CRACU1-4E
CRACU1-4F
CRACU1-4G
2" CONDENSATE
DRAIN.SLOPE
DOWN TO ROOF
DRAIN
TS
MOUNT ON ROOF
SUPPORT
UNIT
THERMOSTAT
DDC TEMPERATURE
SENSOR HI/LO ALARM
PROVIDE SPLASH
BLOCK ON ROOF
3/4" CONDENSATE DRAIN AT
HEIGHT OF INDOOR UNIT
PROVIDE MANUFACTURER'S
LINE SET. MOUNT TO ROOF
DECK
4" CHS DN
4" CHR DN
4" HWS DN
4" HWR DN
1 2
66x24 UP
TO ERU
x4
32x36
76"x40" DN TO CHASE
46"x30" DN TO CHASE
AHU-4-RA SOUND
ATTENUATOR
AHU-4-SA SOUND
ATTENUATOR
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
PL
O
T
SC
AL
E:
PL
O
T D
AT
E:
SHEET OF
1909 CYPRESS AVENUE
VIRGINIA BEACH, VA 23451
(757) 417 - 0140
Six Columbus Center 4505 Columbus St. Ste 200 Virginia Beach, VA 23462
As in di ca te d
8/
/ 2
7:
: 3
PM
DE
FE
NS
E
LO
GI
ST
IC
S
AG
EN
CY
- A
VI
AT
I O
N D S
CR
, R
IC
HM
O N D, V A
N
O V
Norfolk District
D
KH
D
LS
, D R
F
JC
S
MP122
N O
R
FO
LK
D
I S
TR
IC
T
N o r fo lk
, V A
W
AL
LE
R
, T O
D D
S
AD
LE
R A
R C
H
IT
EC
TS
C
YP
R
ES
S
AV
EN
U
E
VI
R G
IN
IA
B
EA
C H
, V
IR
G
IN
IA
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
C
LL
855589
R O
O F
PL
AN
AR
E A 'D
6 '
H V A
C P I
PI
N
G
D L A
O P S
C
EN
TE
R
P H
AS
E
I
M
4- M
P 1
- W
6-
-D
-0
TO
-0
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
04 8 16268
SCALE: 1/8"=1'-0"
1/8" = 1'-0"
ROOF PLAN - AREA D6' - HVAC
NOTE:
MAINTAIN MANUFACTURER'S RECOMMENDED
MAINTENANCE CLEARANCE.
PROVIDE P-TRAP. SEE DETAIL SHEET M-501.
PIPIING ENCLOSURE. NO ROOF DECKING
BELOW.
SOLAR PANELS. SEE PLUMBING DRAWING
P-116.
MOUNT INDOOR UNIT SO THAT BOTTOM OF UNIT
IS 3" ABOVE TOP OF DOOR FRAME.
ACCESS PLATFORM ROOF CURB.
ACCESS LADDER.
DUCT THRU ROOF, SEE TYPICAL DETAILS ON
A-501.
SEE DUCT SUPPORT DETAIL A1/M-505.
PROVIDE SMOKE DAMPER AT AHU SUPPLY AIR
DISCHARGE. DAMPER SHALL BE ACCESSIBLE
FROM ROOF LEVEL THROUGH ROOF CURB. SEE
ACOUSTICAL ROOF CURB DETAIL, SHEET M-505.
PROVIDE HEAT TRACE ON ALL CHS, CHR,
HWS, AND HWR PIPING INSIDE
ENCLOSURE.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
liliia.kolesnyk Snapshot
| Sheets |
| MP122 - ROOF PLAN - AREA 'D6' - HVAC PIPING |
File details come from the government source that posted it. Updated .