About this file

This document is a technical drawing, specifically a roof plan for HVAC piping in Area 'D6' of a federal facility. The drawing includes details on the layout of the HVAC equipment, condensate drains, piping, and associated requirements such as maintaining manufacturer clearances, providing p-traps, and adding heat tracing.

The related federal contract opportunity is for the B46 Rooftop HVAC Insulation and Cladding project at the Defense Supply Center Richmond (DSCR) facility. This is a construction solicitation issued as an RFP under Simplified Acquisition Procedures. The contract will be firm-fixed price with a 180-day period of performance. The NAICS code is 238220 (Plumbing, Heating, and Air Conditioning Contractors) with a $19M small business size standard. A site visit is scheduled for August 28, 2024, and quotes are due on September 6, 2024. The award will be made to the lowest priced, technically acceptable offeror.

View the file

Other files for this federal contract opportunity

Other files attached to B46 Rooftop HVAC Insulation and Cladding, newest first.
File Type Posted
MP-121.pdf PDF
Addendum to RFP - Offer Requirements.pdf PDF
Wage Determination.pdf PDF
Tab 2 - SOW - B46 Rooftop HVAC Insulation and Cladding.pdf PDF
SP470324R0033.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

J

J

J

KEY PLAN

NO SCALE

'B6' 'D6'

49x30 OA

DUCT TO

AHU-4

9TYP

TYP

CRACU1-4E

CRACU1-4F

CRACU1-4G

2" CONDENSATE

DRAIN.SLOPE

DOWN TO ROOF

DRAIN

TS

MOUNT ON ROOF

SUPPORT

UNIT

THERMOSTAT

DDC TEMPERATURE

SENSOR HI/LO ALARM

PROVIDE SPLASH

BLOCK ON ROOF

3/4" CONDENSATE DRAIN AT

HEIGHT OF INDOOR UNIT

PROVIDE MANUFACTURER'S

LINE SET. MOUNT TO ROOF

DECK

4" CHS DN

4" CHR DN

4" HWS DN

4" HWR DN

1 2

66x24 UP

TO ERU

x4

32x36

76"x40" DN TO CHASE

46"x30" DN TO CHASE

AHU-4-RA SOUND

ATTENUATOR

AHU-4-SA SOUND

ATTENUATOR

SHEET

IDENTIFICATION

1 2 3 4 5

D R

AW

N

B Y:

D

ES

I G N

B Y:

SB

M

T

BY

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

C

KD

B Y:

US Army Corps of Engineers ®

" x

4"

D

C

B

A

FI

LE

N U

M

BE

R

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

SHEET OF

1909 CYPRESS AVENUE

VIRGINIA BEACH, VA 23451

(757) 417 - 0140

Six Columbus Center 4505 Columbus St. Ste 200 Virginia Beach, VA 23462

As in di ca te d

8/

/ 2

7:

: 3

PM

DE

FE

NS

E

LO

GI

ST

IC

S

AG

EN

CY

- A

VI

AT

I O

N D S

CR

, R

IC

HM

O N D, V A

N

O V

Norfolk District

D

KH

D

LS

, D R

F

JC

S

MP122

N O

R

FO

LK

D

I S

TR

IC

T

N o r fo lk

, V A

W

AL

LE

R

, T O

D D

S

AD

LE

R A

R C

H

IT

EC

TS

C

YP

R

ES

S

AV

EN

U

E

VI

R G

IN

IA

B

EA

C H

, V

IR

G

IN

IA

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

C

LL

855589

R O

O F

PL

AN

AR

E A 'D

6 '

H V A

C P I

PI

N

G

D L A

O P S

C

EN

TE

R

P H

AS

E

I

M

4- M

P 1

- W

6-

-D

-0

TO

-0

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

04 8 16268

SCALE: 1/8"=1'-0"

1/8" = 1'-0"

ROOF PLAN - AREA D6' - HVAC

NOTE:

MAINTAIN MANUFACTURER'S RECOMMENDED

MAINTENANCE CLEARANCE.

PROVIDE P-TRAP. SEE DETAIL SHEET M-501.

PIPIING ENCLOSURE. NO ROOF DECKING

BELOW.

SOLAR PANELS. SEE PLUMBING DRAWING

P-116.

MOUNT INDOOR UNIT SO THAT BOTTOM OF UNIT

IS 3" ABOVE TOP OF DOOR FRAME.

ACCESS PLATFORM ROOF CURB.

ACCESS LADDER.

DUCT THRU ROOF, SEE TYPICAL DETAILS ON

A-501.

SEE DUCT SUPPORT DETAIL A1/M-505.

PROVIDE SMOKE DAMPER AT AHU SUPPLY AIR

DISCHARGE. DAMPER SHALL BE ACCESSIBLE

FROM ROOF LEVEL THROUGH ROOF CURB. SEE

ACOUSTICAL ROOF CURB DETAIL, SHEET M-505.

PROVIDE HEAT TRACE ON ALL CHS, CHR,

HWS, AND HWR PIPING INSIDE

ENCLOSURE.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

liliia.kolesnyk Snapshot

Sheets
MP122 - ROOF PLAN - AREA 'D6' - HVAC PIPING