MP-121.pdf
PDF 346 KB Posted
- Attached to
- B46 Rooftop HVAC Insulation and Cladding Federal contract opportunity
- Solicitation number
- SP4703-24-R-0033
- Issued by
- Defense Logistics Agency
About this file
This document is a solicitation for the B46 Rooftop HVAC Insulation and Cladding project at the Defense Supply Center Richmond (DSCR) facility. It is a request for proposal (RFP) issued as a firm-fixed price Purchase Order with a 180-day period of performance. The North American Industry Classification System (NAICS) code is 238220 (Plumbing, Heating, and Air Conditioning Contractors) with a $19M small business size standard. A site visit is scheduled on August 28, 2024, and questions are due on August 29, 2024. Quotes are due on September 06, 2024. This acquisition is set aside for 100% small businesses, and award will be made to the lowest priced, technically acceptable offeror that meets the requirements stated in the Statement of Work and the solicitation. Past performance will be considered as part of technical acceptability, and the contractor must be registered in the System for Award Management (SAM) prior to award.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| MP-122.pdf | ||
| Tab 2 - SOW - B46 Rooftop HVAC Insulation and Cladding.pdf | ||
| SP470324R0033.pdf | ||
| Addendum to RFP - Offer Requirements.pdf | ||
| Wage Determination.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
J
J
KEY PLAN
NO SCALE
'B6' 'D6'
2" CONDENSATE
DRAIN. SLOPE
DOWN TO ROOF
DRAIN
M-303
9TYP
NOE:
INSTALL SMOKE DAMPERS
AT AHU RETURN AIR DUCT.
SEE NOTE 9 FOR
ACCESSIBILITY.
CRACU1-4C
CRACU1-4D
48x30 OA
DUCT TO
AHU-3
4" CHS DN
4" CHR DN
3" HWS DN
3" HWR DN
x5
46x24
68x54
46x24 DN
68x54 DN
SP
8TYP
8TYP
AHU-3-RA SOUND
ATTENUATOR
4 5
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
PL
O
T
SC
AL
E:
PL
O
T D
AT
E:
SHEET OF
1909 CYPRESS AVENUE
VIRGINIA BEACH, VA 23451
(757) 417 - 0140
Six Columbus Center 4505 Columbus St. Ste 200 Virginia Beach, VA 23462
As in di ca te d
8/
/ 2
7:
: 3
PM
DE
FE
NS
E
LO
GI
ST
IC
S
AG
EN
CY
- A
VI
AT
I O
N D S
CR
, R
IC
HM
O N D, V A
N
O V
Norfolk District
D
KH
D
LS
, D R
F
JC
S
MP121
N O
R
FO
LK
D
I S
TR
IC
T
N o r fo lk
, V A
W
AL
LE
R
, T O
D D
S
AD
LE
R A
R C
H
IT
EC
TS
C
YP
R
ES
S
AV
EN
U
E
VI
R G
IN
IA
B
EA
C H
, V
IR
G
IN
IA
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
C
LL
855588
R O
O F
PL
AN
AR
E A 'B
6 '
H V A
C P I
PI
N
G
D L A
O P S
C
EN
TE
R
P H
AS
E
I
M
4- M
P 1
- W
6-
-D
-0
TO
-0
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
04 8 16268
SCALE: 1/8"=1'-0"
1/8" = 1'-0"
ROOF PLAN - AREA 'B6' - HVAC
NOTE:
MAINTAIN MANUFACTURER'S RECOMMENDED
MAINTENANCE CLEARANCE.
PROVIDE P-TRAP. SEE DETAIL SHEET M-501.
PIPING ENCLOSURE. NO ROOF DECKING BELOW.
ACCESS PLATFORM ROOF CURB.
ACCESS LADDER.
DUCT THRU ROOF, SEE TYPICAL DETAILS ON A-501.
OUTDOOR AIR STATIC PRESSURE PICK UP PORT.
SEE DUCT SUPPORT DETAIL A1/M-505.
PROVIDE SMOKE DAMPER AT AHU SUPPLY AIR
DISCHARGE. DAMPER SHALL BE ACCESSIBLE FROM
ROOF LEVEL THROUGH ROOF CURB. SEE
ACOUSTICAL ROOF CURB DETAIL, SHEET M-505.
PROVIDE HEAT TRACE ON ALL EXPOSED
CHS, CHR, HWS, AND HWR PIPING ABOVE
ROOF.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
| Sheets |
| MP121 - ROOF PLAN - AREA 'B6' - HVAC PIPING |
File details come from the government source that posted it. Updated .