This document is a Request for Quote (RFQ) for the repair of the ceiling and walls in Building 34 at the Defense Supply Center Richmond (DSCR). The solicitation number is SP4703-24-Q-0067, and the project is set aside for 100% small businesses under NAICS code 236220 with a $45M size standard. The work has an anticipated period of performance of 120 days from the notice to proceed. The contract will be a firm-fixed-price purchase order. A site visit is scheduled for August 15, 2024, and quotes are due by August 29, 2024. The award will be made to the lowest-priced, technically acceptable offeror that meets the Statement of Work requirements. Past performance will be evaluated as part of technical acceptability, and the contractor must be within a 120-mile radius of the DSCR facility.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attn:

Address:

Order #: 565480

MISC (0)Customer:

Received 05/28/24

Schneider Laboratories Global, Inc 2512 W. Cary Street • Richmond, Virginia • 23220-5117 804-353-6778 • 800-785-LABS (5227) • Fax 804-359-1475

05/28/24Analyzed

05/28/24Reported

Analysis Report

PLM Analysis

Cust. IDSample ID LocationCollected Asbestos Fibers Other Materials

EPA 600/R-93/116 & 40 CFR App. E Sub. E Pt. 763Method:

Project: Bldg 34 Hallway Ceiling

Number:

Location: 6090 Strathmore Rd

6090 Strathmore Rd05/28/24 001565480-001

Gray, Granular

PlasterLayer 1: No Asbestos Detected CELLULOSE FIBER2%

NON FIBROUS MATERIAL98%

White, Granular

Skim CoatLayer 2: No Asbestos Detected NON FIBROUS MATERIAL100%

Analyst

Reviewed By: Senhory Abdellatif

Total layers analyzed on order: 2 565480-05/28/24 01:20 PM

EPA Regulatory Limit: 1%

Analyst Michael Alers

Reporting Limit: 1% Gravimetrically Reduced Reporting Limit: 0.01% PLM analysis is based on Visual Estimation and NESHAP recommends that any friable sample with an asbestos content less than 10 percent be verified by Point Count or TEM Analysis. The EPA recommends that any attic loose fill vermiculite should be treated as asbestos containing material. This report must not be reproduced except in full with the approval of the laboratory. The test results apply to the sample as received.