HZ2M_N_0301.pdf

PDF 1 MB Posted

Attached to
Electrical and Mechanical Upgrades for ESCC Relocation for Bldg 58 Federal contract opportunity
Solicitation number
SP4702-16-R-0006
Issued by
Defense Logistics Agency Land and Maritime

View the file

Other files for this federal contract opportunity

Other files attached to Electrical and Mechanical Upgrades for ESCC Relocation for Bldg 58, newest first.
File Type Posted
SP470216R00060002.pdf PDF
HZ2A_N_0301.pdf PDF
HZ2A_N_0302.pdf PDF
WSHP_15_Technical_Data_Sheet.pdf PDF
HZ2A_N_0411.pdf PDF
HZ2A_N_0104.pdf PDF
SP470216R00060001.pdf PDF
SP470216R0006.pdf PDF
Atch___2_Scope_of_Work.pdf PDF
Atch___1_16R0006_SECTION_L_ _M.pdf PDF
Atch___4_DOL_Wage_Rate_Determination.pdf PDF
Atch___5_Construction_Cost_Estimate.xlsx XLSX spreadsheet
Atch___3_CSC-15750_FINAL_DRAWING_SET_revised.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EL: 0'-0"

FINISHED FLOOR

EL: 2'-8"

BOTTOM OF OPENING

EL: 9'-0"

CEILING

EL: 8'-0"

TOP OF OPENING

EL: 11'-4"

TOP OF CMU

LD-1

40 CFM

6Ø

8Ø

8" CD

170 CFM

6x6 RG

90 CFM

6x6

12x12

8x6

18x20

8Ø

Ø

10" CD

325 CFM

14x14(L)

12x12(L)

8Ø

8" CD

150 CFM

10x10(L)

8x8 RG

270 CFM

10Ø

10" CD

310 CFM

14x14(L)

10Ø

6Ø

6x6 RG

115 CFM

6x6

12Ø

10Ø

14x14(L) BEHIND

14x14(L)2" CTS/CTR2" CTS/CTR

PAN

10" CD

310 CFM

10Ø

8" CD

165 CFM

12x12 RG

580 CFM

14x14(L)

8x8

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

D e s c r i p t i o n S y m b o l A p p r

R e v i s i o n s

5 4 3 2 1

A

B

C

D

US Army Corps of Engineers

Louisville District

P r o j e c t

A r c h i t e c t E n g i n e e r

5 4 3 2 1

D

A

B

C

D

SHEET OF

SHEET

REFERENCE

NUMBER:

D a t e

S c a l e

D r a w i n g

C o d e

D e s i g n e d b y

C h e c k e d b y

D r a w n b y

K N

I G

H T

A

R C

H I T

E C

T S

I N

C A

E C

O M

S

N

O T

E D

D E

F E

N S

E

S

U P

P L Y

C

E N

T E

R

C

O L U

M B

U S

R E

P L A

E

P

U B

L I

S

F

E T

Y

F

A C

I L I T

Y

C O

L U

M B

U S

O

H I O

S O

L I C

I T

A T

I O

N

N

O

W

Q

R R

P N

C

S C

P

F

M E

C H

A N

I C

A L

S E

C T

I O

N

M301

N

P

A T

E L

D

H

U A

N G

M

W

R I G

H T

J U

L

76 116

M-301

MECHANICAL SECTION

SCALE: 1/8" = 1'-0"

1"

PRV 10PSIG

FS

3"

AIRTROL FITTING

3/4" FROM GPU

3"

C T

S

STANDBY

3/4"

HOSE CONNECTION

10" 10"

3/4" GLOBE VALVE

3"

3" 3"

FS

2 1/2"(TYP)

POT FEEDER

CHEMICAL

TO WSHP LOOP

FROM WSHP LOOP

M301

PIPING DIAGRAM

SCALE: NONE

NON-CHEMICAL WATER

TREATMENT SYSTEM

FROM WSHP LOOP

3/4"

CALIBRATED BALANCING VALVE (TYP)

ASME PRV (TYP)

3"

3"BYPASS VALVE

3"4"

4"

3"

1"

3"

PS

TO FROM MAU-1

GENERAL NOTES

1. FOR GENERAL NOTES AND LEGEND, SEE M001.

2. FOR SCHEDULES, SEE M002 & M003.

CW

INSTALL NEAR ROOM 141, PER MP101

SP470216R0006-0002

Attachment # 6 Source Selection Information See FAR 2.101 and 3.104 For Official Use Only

File details come from the government source that posted it. Updated .