HZ2A_N_0411.pdf

PDF 677 KB Posted

Attached to
Electrical and Mechanical Upgrades for ESCC Relocation for Bldg 58 Federal contract opportunity
Solicitation number
SP4702-16-R-0006
Issued by
Defense Logistics Agency Land and Maritime

View the file

Other files for this federal contract opportunity

Other files attached to Electrical and Mechanical Upgrades for ESCC Relocation for Bldg 58, newest first.
File Type Posted
SP470216R00060002.pdf PDF
HZ2A_N_0301.pdf PDF
HZ2A_N_0302.pdf PDF
HZ2M_N_0301.pdf PDF
HZ2A_N_0104.pdf PDF
WSHP_15_Technical_Data_Sheet.pdf PDF
SP470216R00060001.pdf PDF
SP470216R0006.pdf PDF
Atch___5_Construction_Cost_Estimate.xlsx XLSX spreadsheet
Atch___3_CSC-15750_FINAL_DRAWING_SET_revised.pdf PDF
Atch___2_Scope_of_Work.pdf PDF
Atch___1_16R0006_SECTION_L_ _M.pdf PDF
Atch___4_DOL_Wage_Rate_Determination.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A411

FLOOR DRAIN DETAIL

NOT TO SCALE

A411

INTERIOR RECESSED WALK-OFF MAT DETAIL

NOT TO SCALE

A411

DRY ERASE BOARD DETAIL

NOT TO SCALE

A411

CORNER GUARD DETAIL

NOT TO SCALE

A411

SEMI-RECESSED FIRE EXTINGUSHER CABINET DETAIL

NOT TO SCALE

A411

FIXED ACCESS LADDER DETAIL

NOT TO SCALE

A411

BULLETIN BOARD DETAIL

NOT TO SCALE

BOTTOM OF CABINET

3'-0" AFF

METAL STUD WALL ASSEMBLY

SEMI-RECESSED FIRE

EXTINGUISHER CABINET

FACTORY FRAMED

HEAVY-DUTY

ALUMINUM TRIM

WOOD BLOCKING

BACKER BOARD

PORCELAIN ON STEEL

MAGNETIC DRY-ERASE

WHITE BOARD WITH

SMOOTH LOW-GRADE

SURFACE

FACTORY FRAMED

HEAVY-DUTY

ALUMINUM TRIM

MAP RAIL

WOOD BLOCKING

A

F

F

CORK INSERT

AT CERAMIC TILE FLOORS:

THIN SET MORTAR BED PITCHED

TO THE DRAIN AT 1/8" PER FOOT

AT CONCRETE FLOORS, TOP

OF DRAIN TO BE AT SAME

ELEVATION AS TOP OF SLAB.

PERIMETER

SEALANT

JOINT

TOP OF STRUCTURAL SLAB

SECTION (DIRECTION OF TRAFFIC)

SECTION (WIDTH)

10'-0" @ DOOR 100A

4'-0" @ DOORS 100B AND 100C

DIRECTION OF TRAFFIC

3/4"3/4"

3/4"

5'-6" @ DOOR 100A

4'-0" @ DOORS 100B AND 100C

3/4"

WIDTH OF MAT

GROUT

SOLID

GROUT

SOLID

ALUMINUM KEY BAR

REMOVABLE/ROLL-UP EXTRUDED

ALUMINUM RAIL

1. PROVIDE CORNER GUARDS AT EVERY GYPSUM

OUTSIDE CORNER IN THE BUILDING INCLUDING EDGE

OF PILASTERS IN CORRIDORS.

2. ALL CORNER GUARDS TO EXTEND FROM TOP

OF WALL BASE TO 7'-0" ABOVE FINISHED FLOOR.

NOTES:

2"

2" X 2" RESILIENT CORNER GUARD WITH

EMBOSSED STIPPLE TEXTURE MOUNTED

ON AN EXTRUDED ALUMINUM RETAINER.

SEE SPECIFICATIONS SECTION 09 06 90

FOR COLOR

REMOVABLE/ROLL-UP EXTRUDED

ALUMINUM RAIL

GROUT

SOLID

GROUT

SOLID

FACTORY FRAMED

HEAVY-DUTY

ALUMINUM TRIM

WOOD BLOCKING

BACKER BOARD

CORK BULLETIN

BOARD

FACTORY FRAMED

HEAVY-DUTY

ALUMINUM TRIM

WOOD BLOCKING

F

F

A411

MECHANICAL PLATFORM DETAIL

NOT TO SCALE

LIGHT GAUGE METAL TRUSS

1-1/4" SCHEDULE 40 PIPE

GUARDRAIL (TYP)

1-1/4" SCHEDULE 40 PIPE GUARDRAIL

SUPPORTS @ 5'-0" O.C.

3/4" STEEL GRATING

4" COLD FORMED METAL FRAMING

AT 24" O.C. SEE STRUCTURAL FOR

FRAMING ATTACHMENT DETAILS

A411

CEILING ACCESS PANEL DETAIL

NOT TO SCALE

SIDE ELEVATION

S

E C

U R

I T

Y

D O

O R

S

E C

U R

I T

Y

D O

O R

7"

MIN.

FRONT ELEVATION

S

E C

U R

I T

Y

D O

O R

S

E C

U R

I T

Y

D O

O R

NOTES:

1. ALUMINUM LADDER TO BE CONSTRUCTED

OF 6061-T6 ALUMINUM ALLOY.

2. RUNGS ARE TO BE 1-1/8"Ø SERRATED AND

SECURED WITH CAST ALUMINUM CONNECTORS.

3. SECURITY DOORS TO BE FABRICATED FROM

0.188" (4.8 MM) THICK ALUMINUM SHEETS WITH

SECURING PIANO HINGES AND HASPS.

4. ALUMINUM LADDER AND ACCESSORIES SHALL

HAVE MILL FINISH.

1 1/2" CHANNEL FRAMED @ OPENING

GYPSUM BOARD CEILING SYSTEM

LOCKABLE METAL ACCESS PANEL

(PAINT TO MATCH CEILING).

PROVIDE TAMPER PROOF SCREWS

AT EXPOSED SURFACES.

ATTACH GUARDRAIL TO GRATING WITH

KEE KLAMP TYPE 262 AND G CLIP GM

BY SAFETY OR APPROVED EQUAL

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

D e s c r i p t i o n S y m b o l A p p r

R e v i s i o n s

5 4 3 2 1

A

B

C

D

US Army Corps of Engineers

Louisville District

P r o j e c t

A r c h i t e c t E n g i n e e r

5 4 3 2 1

D

A

B

C

D

SHEET OF

SHEET

REFERENCE

NUMBER:

D a t e

S c a l e

D r a w i n g

C o d e

D e s i g n e d b y

C h e c k e d b y

D r a w n b y

K N

I G

H T

R C

H I T

E C

T S

I N

C A

E C

O M

S

N

O T

E D

D E

F E

N S

E

S

U P

P L Y

C

E N

T E

R

C

O L U

M B

U S

R E

P L A

P

U B

L I

F

E T

Y

F

A C

I L I T

Y

C O

L U

M B

U S

O

H I O

S O

L I C

I T

A T

I O

N

N

O

W

Q

R R

P N

C

S C

P

F

I N

T E

R I O

R

D E

T A

I L

S

A411

J W

H I T

T E

M O

R E

J W

H I T

T E

M O

R E

J K

N I G

H T

J U

L

45 116

A

A

R E

V I S

D

B

U I L

T S

SP470216R0006-0002

Attachment # 5 Source Selection Information See FAR 2.101 and 3.104 For Official Use Only

File details come from the government source that posted it. Updated .