HZ2A_N_0104.pdf

PDF 596 KB Posted

Attached to
Electrical and Mechanical Upgrades for ESCC Relocation for Bldg 58 Federal contract opportunity
Solicitation number
SP4702-16-R-0006
Issued by
Defense Logistics Agency Land and Maritime

View the file

Other files for this federal contract opportunity

Other files attached to Electrical and Mechanical Upgrades for ESCC Relocation for Bldg 58, newest first.
File Type Posted
WSHP_15_Technical_Data_Sheet.pdf PDF
HZ2A_N_0411.pdf PDF
HZ2A_N_0301.pdf PDF
HZ2A_N_0302.pdf PDF
HZ2M_N_0301.pdf PDF
SP470216R00060002.pdf PDF
SP470216R00060001.pdf PDF
Atch___2_Scope_of_Work.pdf PDF
Atch___1_16R0006_SECTION_L_ _M.pdf PDF
Atch___4_DOL_Wage_Rate_Determination.pdf PDF
SP470216R0006.pdf PDF
Atch___5_Construction_Cost_Estimate.xlsx XLSX spreadsheet
Atch___3_CSC-15750_FINAL_DRAWING_SET_revised.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A104

ATTIC PLAN

SCALE: 1/8" = 1'-0"

MECHANICAL WALKWAY/PLATFORM WITH 3/4"

STEEL GRATING ON COLD FORMED

METAL FRAMING AT 24" O.C. SEE DETAIL

8/A411 - TYP. COORDINATE PLATFORM SIZE

WITH MANUFACTURER TO ENSURE ADEQUATE

CLEARANCES AT WSHP'S AND EXHAUST FANS

WATER SOURCE HEAT PUMP (WSHP), TYP.

36" X 48" SMOKE RESISTANT CEILING

ACCESS PANEL BELOW - REFER TO DETAIL

9/A411.

EXHAUST FAN,

TYP. OF 4.

ACCESS TO MECHANICAL WALKWAYS SHALL

BE FROM CONCRETE CAP ON TOP OF ARMORY

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

D e s c r i p t i o n S y m b o l A p p r

R e v i s i o n s

5 4 3 2 1

A

B

C

D

US Army Corps of Engineers

Louisville District

P r o j e c t

A r c h i t e c t E n g i n e e r

5 4 3 2 1

D

A

B

C

D

SHEET OF

SHEET

REFERENCE

NUMBER:

D a t e

S c a l e

D r a w i n g

C o d e

D e s i g n e d b y

C h e c k e d b y

D r a w n b y

K N

I G

H T

A

R C

H I T

E C

T S

I N

C A

E C

O M

S

N

O T

E D

D E

F E

N S

E

S

U P

P L Y

C

E N

T E

R

C

O L U

M B

U S

R E

P L A

P

U B

L I

F

E T

Y

F

A C

I L I T

Y

C O

L U

M B

U S

O

H I O

S O

L I C

I T

A T

I O

N

N

O

W

Q

R R

P N

C

S C

P

F

GENERAL NOTES:

GN 1. SEE MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF WATER

SOURCE HEAT PUMPS.

SEE STRUCTURAL DRAWINGS FOR LOADING AND FRAMING

REQUIREMENTS FOR MECHANICAL WALKWAYS AND PLATFORMS.

COORDINATE EXACT MECHANICAL WALKWAY AND PLATFORM

LAYOUT WITH HVAC AND TRUSS LAYOUT. NOTIFY A/E OF ANY

CONFLICTS.

A T

T I

P

A

N

A104

J W

H I T

T E

M O

R E

J W

H I T

T E

M O

R E

J K

N I G

H T

J U

34 116

GN 2.

GN 3.

A

A

A

R E

V I S

D

B

U I L

T S

SP470216R0006-0002

Attachment # 2 Source Selection Information See FAR 2.101 and 3.104 For Official Use Only

File details come from the government source that posted it. Updated .