HZ2A_N_0104.pdf
PDF 596 KB Posted
- Attached to
- Electrical and Mechanical Upgrades for ESCC Relocation for Bldg 58 Federal contract opportunity
- Solicitation number
- SP4702-16-R-0006
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| WSHP_15_Technical_Data_Sheet.pdf | ||
| HZ2A_N_0411.pdf | ||
| HZ2A_N_0301.pdf | ||
| HZ2A_N_0302.pdf | ||
| HZ2M_N_0301.pdf | ||
| SP470216R00060002.pdf | ||
| SP470216R00060001.pdf | ||
| Atch___2_Scope_of_Work.pdf | ||
| Atch___1_16R0006_SECTION_L_ _M.pdf | ||
| Atch___4_DOL_Wage_Rate_Determination.pdf | ||
| SP470216R0006.pdf | ||
| Atch___5_Construction_Cost_Estimate.xlsx | XLSX spreadsheet | |
| Atch___3_CSC-15750_FINAL_DRAWING_SET_revised.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A104
ATTIC PLAN
SCALE: 1/8" = 1'-0"
MECHANICAL WALKWAY/PLATFORM WITH 3/4"
STEEL GRATING ON COLD FORMED
METAL FRAMING AT 24" O.C. SEE DETAIL
8/A411 - TYP. COORDINATE PLATFORM SIZE
WITH MANUFACTURER TO ENSURE ADEQUATE
CLEARANCES AT WSHP'S AND EXHAUST FANS
WATER SOURCE HEAT PUMP (WSHP), TYP.
36" X 48" SMOKE RESISTANT CEILING
ACCESS PANEL BELOW - REFER TO DETAIL
9/A411.
EXHAUST FAN,
TYP. OF 4.
ACCESS TO MECHANICAL WALKWAYS SHALL
BE FROM CONCRETE CAP ON TOP OF ARMORY
*** SAFETY PAYS ***
*** SUPPORT VALUE ENGINEERING - IT PAYS ***
D e s c r i p t i o n S y m b o l A p p r
R e v i s i o n s
5 4 3 2 1
A
B
C
D
US Army Corps of Engineers
Louisville District
P r o j e c t
A r c h i t e c t E n g i n e e r
5 4 3 2 1
D
A
B
C
D
SHEET OF
SHEET
REFERENCE
NUMBER:
D a t e
S c a l e
D r a w i n g
C o d e
D e s i g n e d b y
C h e c k e d b y
D r a w n b y
K N
I G
H T
A
R C
H I T
E C
T S
I N
C A
E C
O M
S
N
O T
E D
D E
F E
N S
E
S
U P
P L Y
C
E N
T E
R
C
O L U
M B
U S
R E
P L A
P
U B
L I
F
E T
Y
F
A C
I L I T
Y
C O
L U
M B
U S
O
H I O
S O
L I C
I T
A T
I O
N
N
O
W
Q
R R
P N
C
S C
P
F
GENERAL NOTES:
GN 1. SEE MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF WATER
SOURCE HEAT PUMPS.
SEE STRUCTURAL DRAWINGS FOR LOADING AND FRAMING
REQUIREMENTS FOR MECHANICAL WALKWAYS AND PLATFORMS.
COORDINATE EXACT MECHANICAL WALKWAY AND PLATFORM
LAYOUT WITH HVAC AND TRUSS LAYOUT. NOTIFY A/E OF ANY
CONFLICTS.
A T
T I
P
A
N
A104
J W
H I T
T E
M O
R E
J W
H I T
T E
M O
R E
J K
N I G
H T
J U
34 116
GN 2.
GN 3.
A
A
A
R E
V I S
D
B
U I L
T S
SP470216R0006-0002
Attachment # 2 Source Selection Information See FAR 2.101 and 3.104 For Official Use Only
File details come from the government source that posted it. Updated .