Anniston_Bid_Schedule_120414.xlsx

XLSX spreadsheet 216 KB Posted

Attached to
Anniston & Anniston Sandblast Hazard Waste
Solicitation number
SP4500-15-R-0006
Issued by

About this file

Bid Schedule

View the file

Other files

File Type Posted
SF30_15R06_Am07.pdf PDF
15R06_Updated_BidSchedule_Am07_Att01.xlsx XLSX spreadsheet
15R06_Updated_BidSchedule_Am06_Att01.xlsx XLSX spreadsheet
SF30_15R06_Am06.pdf PDF
Am06_Att02_SP450010D0018_Task_Order_Ultimate_Disposal_Reports.pdf PDF
SF30_15R06_Am05.pdf PDF
15R06_Updated_BidSchedule_Am05_Att01.xlsx XLSX spreadsheet
SF30_15R06_Am04.pdf PDF
PUPs_Anniston_Att01.xls XLS spreadsheet
Facility-CLIN_Assignment_Sheet_Am04_Att03.xlsx XLSX spreadsheet
15R06_Updated_BidSchedule_Am04_Att02.xlsx XLSX spreadsheet
15R06_Updated_BidSchedule_Amend03_Att02.xlsx XLSX spreadsheet
SF30_15R06_Am03.pdf PDF
Amend03_Attach01_ASB_13D11_Sandblast_ERS_Report.xls XLS spreadsheet
Anniston_Amend_2.pdf PDF
Anniston_ERS_Report.xls XLS spreadsheet
Anniston_Bid_Schedule_Attachment_02_.xlsx XLSX spreadsheet
SP450015R0006._Attachment_01pdf.pdf PDF
Anniston__Amend_1.docx DOCX document
SP450015R0006.pdf PDF
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Base Period

Anniston Army Depot/Redstone Arsenal Regional Disposal Contract - Base Period
Base
CLINWaste DescriptionCLINEst. QtyU/IPriceExtended Price
6000 Series CLINs
6310AAProvide metal containers with lids for repackaging, 55-gallon to 85-gallon size, meeting DOT requirements.6310AA5EA$ - 0
6311AAProvide service to place waste in containers - up to one 5 gal container.6311AA5EA$ - 0
6312C2Provide container, 5 gal, UN 1H2/Y30/S open screw-top plastic pail with locking lid, new.6312C2100EA$ - 0
6312C3Provide x100 containers, 5 gal Poly w/ screw-top lid, 1H2/Y27, (1 EA = Qty 100).6312C32EA$ - 0
6312C4Provide x100 containers, 5 gal poly, tight head, rectangular body, w/o caps, (1 EA = Qty 100).6312C42EA$ - 0
6312D1Provide container, 15 gal, UN 1H2/Y100/S open head, plastic, new.6312D1100EA$ - 0
6312D3Provide x200 containers, 15 gal steel, open top, plain lid, new, (1 EA = Qty 200).6312D31EA$ - 0
6312D4Provide x100 quick release rings to fit CLIN 6312D3 (1 EA = Qty 100).6312D42EA$ - 0
6312F2Provide container, 30 gal. UN 1H2/Y open top, plastic, new.6312F2150EA$ - 0
6312F6Provide x200 containers, 30 gal steel, open top, new, UN 1A1/X1.3/300 (1 EA = Qty 200).6312F61EA$ - 0
6312F7Provide x100 quick relase rings to fit CLIN 6312F6 (1 EA = Qty 100).6312F72EA$ - 0
6312GAProvide x50 containers, 55 gal steel, open top, bung lid, new or reconditioned, UN 1A2/Y1.2/100 (1 EA = qty 50).6312GA1EA$ - 0
6312GBProvide x50 quick release rings to fit CLIN 6312GA (1 EA = qty 50).6312GB1EA$ - 0
6312GDProvide x50 containers, 55 gal steel, closed top, new or reconditioned, 1A1/X1.4/300 (1 EA = qty 50).6312GD2EA$ - 0
6312GEProvide x50 containers, 55 gal poly, tight head, new, 1H1/Y1.8/100 (1 EA = Qty 50).6312GE2EA$ - 0
6312J3Provide 300 pallets, reconditioned acceptable, to fit CLIN 6312K3 (1 EA = Qty 300).6312J32EA$ - 0
6312K3Provide x200 one-cubic-yard boxes, tri-walled corrugated cardboard, w/ straps, liners, and nails, UN11G/X/ (1 EA = 200).6312K32EA$ - 0
6312M3Provide x20 fluorescent tube drums, 8-ft fiber, UN (1 EA = Qty 20).6312M310EA$ - 0
6312M4Provide x20 fluorescent tube drums, 4-ft fiber, UN 1G/Y50/S (1 EA = Qty 20).6312M410EA$ - 0
6318Tote Return Surcharge, for return of empty Government-owned totes up to 330-gal. Ordered in addition to bulk disposal CLIN.631840EA$ - 0
6320Provide and prepare lab packs, consisting of small quantity chemicals (56-85 gal) (See 3.7).632010EA$ - 0
6321Provide and prepare lab packs, consisting of small quantity chemicals (55 gal) (See 3.7).6321110EA$ - 0
6322Provide and prepare lab packs, consisting of small quantity chemicals (20-30 gal) (See 3.7).63225EA$ - 0
6323Provide and prepare lab packs, consisting of small quantity chemicals (5-15 gal) (See 3.7).632375EA$ - 0
6330Expedited removal - 15 days (See 1.2.11).63302EA$ - 0
6331Expedited removal - 10 days (See 1.2.11).63312EA$ - 0
6332Expedited removal - 7 days (See 1.2.11).63323EA$ - 0
6333Expedited removal - 5 days (See 1.2.11).63335EA$ - 0
6334Expedited removal - 3 days (See 1.2.11).63345EA$ - 0
6335Expedited removal - 1 day (See 1.2.11).633515EA$ - 0
6340Expedited performance - 15 days (See 1.2.11).63405EA$ - 0
6341Expedited performance - 10 days (See 1.2.11).63415EA$ - 0
6342Expedited performance - 7 days (See 1.2.11).63425EA$ - 0
6343Expedited performance - 5 days (See 1.2.11).63435EA$ - 0
6344Expedited performance - 3 days (See 1.2.11).63445EA$ - 0
6345Expedited performance - 1 day (See 1.2.11).634515EA$ - 0
6350AATank cleaning/services – above ground, 1 to 999 gallon capacity (See 3.2).6350AA25EA$ - 0
6350BBTank cleaning/cervices – above ground, 1,000 to 3,000 gal capacity (See 3.2).6350BB125EA$ - 0
6350CCTank cleaning/services – above ground, 3,001 to 6,000 gal capacity (See 3.2).6350CC5EA$ - 0
6350DDTank cleaning/services – above ground, 6,001 to 12,000 gal capacity (See 3.2).6350DD5EA$ - 0
6351AATank cleaning/services – below ground, 1 to 999 gal capacity (See 3.2).6351AA20EA$ - 0
5351BBTank cleaning/services – below ground, 1,000 to 3,000 gal capacity (See 3.2).5351BB5EA$ - 0
6351CCTank cleaning/services – below ground, 3,001 to 6,000 gal capacity (See 3.2).6351CC5EA$ - 0
6351PCCleanout of Lagoons at ANAD [See 3.12].6351PC2EA$ - 0
6352AATank cleaning/services – oil/water separator, 1 to 999 gal capacity (See 3.2).6352AA15EA$ - 0
6352BBTank cleaning/services – oil/water separator, 1,000 to 3,000 gal capacity (See 3.2).6352BB15EA$ - 0
6352CCTank cleaning/services – oil/water separator, 3,001 to 6,000 gal capacity (See 3.2).6352CC15EA$ - 0
6352DDTank cleaning/services – oil/water separator, 6,001 to 12,000 gal capacity (See 3.2).6352DD15EA$ - 0
6353Cleaning/Services charges, pits and vats @ ANAD (See 3.2 & 3.2.1).635315EA$ - 0
6372Provide rolloff (20 CY) (See 3.6).6372150EA$ - 0
6372SCProvide Container - Sludge Bin (20 CY).6372SC35EA$ - 0
6373Provide rolloff (25 CY) (See 3.6).637380EA$ - 0
6374Provide rolloff (30 CY) (See 3.6).637440EA$ - 0
6375Provide rolloff (40 CY) (See 3.6).6375100EA$ - 0
6377Provide storage container - 21,000 gl FRAC tank.637715EA$ - 0
6382Rolloff rental (20CY) (See 3.6).6382135EA$ - 0
6382SCRental - Storage Container - Sludge Bin (20 CY).6382SC20EA$ - 0
6383Rolloff rental (25CY) (See 3.6).638375EA$ - 0
6384Rolloff rental (30CY) (See 3.6).638425EA$ - 0
6385Rolloff rental (40CY) (See 3.6).638512EA$ - 0
6385FCRental - Storage Container - 21,000 GL FRAC Tank (See 3.6).6385FC12EA$ - 0
6387FRAC tank rental (21,000 gl) (See 3.6).638712EA$ - 0
6388Transportation charge (move containers at same location) (See 3.8).638820EA$ - 0
6400AAPrepare waste profile form (See 3.4).6400AA30EA$ - 0
6400TSPerform appropriate analysis to properly identify unknown hazardous property and complete waste profile form (See 3.5).6400TS5EA$ - 0
6401Perform hazardous waste characteristics analysis to determine ignitability (D001), corrosivity (D002), & reactivity (D003) (See 3.3).64011EA$ - 0
6402Perform total TCLP analysis (D0004-D043) (See 3.3).64021EA$ - 0
6403Perform TCLP metals analysis to determine 8 TCLP metals (D004-D011) (See 3.3).64031EA$ - 0
6404Perform TCLP analysis to determine D012-D017 (See 3.3).64041EA$ - 0
6405Perform TCLP analysis to determine volatile and semivolatile organics (D018-D043) (See 3.3).64051EA$ - 0
6406Perform F-series solvent analysis to determine EPA waste codes F001-F005 (See 3.3).64061EA$ - 0
6408Perform total organic halogens analysis (See 3.3).64081EA$ - 0
6409Perform total petroleum hydrocarbons analysis (See 3.3).64091EA$ - 0
6411Perform volatile organics analysis (EPA Method 8240) (See 3.3).64112EA$ - 0
6412Perform analysis to determine physical characteristics (physical state, color, and density) (See 3.3).64121EA$ - 0
6413Perform analysis to determine halogenated volatile organics (EPA Method 8101) (See 3.3).64131EA$ - 0
6414Perform wastewater/nonwastewater determination in accordance with 40 CFR Part 268.2 (See 3.3).64141EA$ - 0
6415Perform BTU and % chlorine analysis (See 3.3).64151EA$ - 0
6416Perform test for the percentage of total chlorine (See 3.3).64161EA$ - 0
6417Perform test for semi-volatile organics as listed in 22 CCR 66268, Appendix III (See 3.3).64171EA$ - 0
6419Perform paint filter test (EPA Method 9095) (See 3.3).64191EA$ - 0
6420Perform the following tests: EPA 8080 PCBs and organochlorine pesticides, EPA 8140 organophosphorous pesticides, EPA 8240 volatile organics, EPA 8270 semi-volatile organics, EPA 9010 cyanides, TCLP metals (8), & CCR TTLC (17) metals. If results of TTLC are 10 times greater than STLC, then run STLC (See 3.3).64201EA$ - 0
6421Perform test for asbestos (See 3.3).64212EA$ - 0
6422Perform analysis to determine benzene, toluene, ethylbenzene, and xylene (See 3.3).64222EA$ - 0
6423Perform analysis to determine cresol (D026) (See 3.3).6423EA$ - 0
6424Perform polychlorinated biphenyl analysis (See 3.3).64242EA$ - 0
6502AAManagement Services - Battery Charging Station Clean-up @ ANAD (See 3.8).6502AA2EA$ - 0
6502BAManagement Services - Mobilization for Pit, Sump, Berm, and Trench cleaning @ ANAD (See 3.9).6502BA12EA$ - 0
6502BBManagement Services - Personnel for Pit, Sump, and Trench cleaning @ ANAD (See 3.9).6502BB55EA$ - 0
6503Provide certificate of disposal (See 2.1.2).6503200EA$ - 0
6610AATransportation Costs for Milk Run (See 3.10).6610AA2EA$ - 0
Profile Based CLINs
BA01Alkaline Batteries, Managed as Universal Waste (UW) for Recycling or Direct Landfill Disposal.

● Physical State: Solid

● Permissible Waste Codes: NA.

BA01C73,200LB$ - 0
BA02Calcium Chromate (CaCrO4) Thermal Batteries, Deactivated, Managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: D001 (Oxidizer), D003-11.BA02C72,500LB$ - 0
BA03Carbon-Zinc (CZn) Batteries, Managed as UW/HW for Recycling or Disposal.

● Physical State: Solid

● Permissible Waste Codes: D002, D004-11.BA03C72,500LB$ - 0
BA04Lead Acid Batteries, Managed as UW/HW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: D002, D004-11.BA04C733,000LB$ - 0
BA05Lithium Ion (Li-Ion) Batteries, Managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: D002-11.BA05C78,000LB$ - 0
BA06Lithium Iron Sulfide (Li2FeS2) Thermal Batteries, Deactivated, Managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: D002-11.BA06C74,500LB$ - 0
BA07Lithium Manganese (LiMn and Oxides thereof) Batteries, Managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: D002-11.BA07C72,500LB$ - 0
BA08Lithium Sulfur Dioxide (LiSO2) Batteries, Managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: D002-11.BA08C715,000LB$ - 0
BA09Lithium Thionyl Chloride (LiSCl) Batteries, Managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: D002-11.BA09C72,500LB$ - 0
BA10Lithium Batteries, Mixed Types, Deactivated if Applicable, Managed as UW/HW for Recycling or Destruction & Disposal.

● Physical State: Solid

● Permissible Waste Codes: D002-11.BA10C715,000LB$ - 0
BA11Magnesium (Mg) Batteries, Managed as UW/HW for Recycling or Destruction and Disposal.

● Physical State: Solid

● Permissible Waste Codes: D002, D004-11.BA11C7300LB$ - 0
BA12Mercury (Hg) Batteries, Managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: D002, D004-11.BA12C7200LB$ - 0
BA13Nickel Metal Hydride (NiMh) Batteries, Managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: D002, D004-11.BA13C71,250LB$ - 0
BA14Nickel-Cadmium (NiCd) Batteries, Managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: D002, D004-11.BA14C710,000LB$ - 0
BA15Silver-Zinc (AgZn) and Zinc Silver Oxidizeride (ZnAgO) Batteries, Managed as UW for Recycling/Recovery Only.

● Physical State: Solid

● Permissible Waste Codes: D002, D004-11.BA15C7100LB$ - 0
CS01Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, <1% Total Metals, Cr+6 <100 ppm.

● Physical State: Liquid

● Permissible Waste Codes: D002, D004-11, Listed Inorganics.CS01C110EA$ - 0
CS01C25EA$ - 0
CS01C35EA$ - 0
CS01C4200EA$ - 0
CS01C51EA$ - 0
CS01B58,000GL$ - 0
CS02Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, >1% Total Metals, Cr+6 <100 ppm.

● Physical State: Liquid

● Permissible Waste Codes: D002, D004-11, Listed Inorganics.CS02C15EA$ - 0
CS02C25EA$ - 0
CS02C35EA$ - 0
CS02C4100EA$ - 0
CS02C51EA$ - 0
CS02B54,000GL$ - 0
CS03Corrosive Acids, Inorganic other than HF and HNO3, Concentrated, <1% Total Metals, Cr+6 <100 ppm.

● Physical State: Liquid

● Permissible Waste Codes: D002, D004-11, Listed Inorganics.CS03C15EA$ - 0
CS03C25EA$ - 0
CS03C35EA$ - 0
CS03C438EA$ - 0
CS03C54EA$ - 0
CS03B52,000GL$ - 0
CS04Corrosive Acids, Chromic (H2Cr04 ), <1% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11.CS04C15EA$ - 0
CS04C25EA$ - 0
CS04C35EA$ - 0
CS04C410EA$ - 0
CS04C52EA$ - 0
CS04B56,000GL$ - 0
CS05Corrosive Acids, Chromic (H2Cr04 ), 1-10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11.CS05C125EA$ - 0
CS05C25EA$ - 0
CS05C35EA$ - 0
CS05C45EA$ - 0
CS05C51EA$ - 0
CS05B56,000GL$ - 0
CS06Corrosive Acids, Chromic (H2Cr04), >10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11.CS06C45EA$ - 0
CS06C51EA$ - 0
CS06B516,000GL$ - 0
CS07Corrosive Acids, Chromic (H2Cr04 ), >100 ppm Cr+6, F-Listed Liquids, Solids, Sludges, Debris.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11, F-Listed.CS07C420EA$ - 0
CS07C52EA$ - 0
CS07B56,000GL$ - 0
CS08Corrosive Acids, Hydrofluoric (HF) and Nitric (HNO3), <50% in Water, <1% Total Metals, Cr+6 <100 ppm.

● Physical State: Liquid

● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11, Listed Inorganics.CS08C110EA$ - 0
CS08C25EA$ - 0
CS08C35EA$ - 0
CS08C45EA$ - 0
CS08C51EA$ - 0
CS09Corrosive Acids, Hydrofluoric (HF) and Nitric (HNO3), >50% in Water, <1% Total Metals, Cr+6 <100 ppm.

● Physical State: Liquid

● Permissible Waste Codes: D001 (Oxidizer), D002, D004-11, Listed Inorganics.CS09C110EA$ - 0
CS09C25EA$ - 0
CS09C35EA$ - 0
CS09C45EA$ - 0
CS09C51EA$ - 0
CS10Corrosive Alkalines, Inorganic, <50% in Water, <1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.

● Physical State: Liquid

● Permissible Waste Codes: D002, D004-11, Listed Inorganics.CS10C15EA$ - 0
CS10C25EA$ - 0
CS10C310EA$ - 0
CS10C4800EA$ - 0
CS10C55EA$ - 0
CS10Corrosive Alkalines, Inorganic, <50% in Water, <1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.

● Physical State: Liquid

● Permissible Waste Codes: D002, D004-11, Listed Inorganics.CS10B526,850GL$ - 0
CS11Corrosive Alkalines, Inorganic, <50% in Water, >1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.

● Physical State: Liquid

● Permissible Waste Codes: D002, D004-11, Listed Inorganics.CS11C15EA$ - 0
CS11C25EA$ - 0
CS11C35EA$ - 0
CS11C45EA$ - 0
CS11C51EA$ - 0
CS12Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/ Sludges/Solids/Debris, Non-Flammable.

● Physical State: Various

● Permissible Waste Codes: D002, D004-11, Listed.CS12C125EA$ - 0
CS12C25EA$ - 0
CS12C325EA$ - 0
CS12C430EA$ - 0
CS12C51EA$ - 0
CS13Corrosive Organic Acids or Bases, Liquids/Sludges/Solids/Debris, No Ammonia/Amines, Non-Flammable.

● Physical State: Various

● Permissible Waste Codes: D002, D004-11, Listed.CS13C110EA$ - 0
CS13C25EA$ - 0
CS13C35EA$ - 0
CS13C415EA$ - 0
CS13C51EA$ - 0
CS14Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries.

● Physical State: Various

● Permissible Waste Codes: D002, D004-11, Listed.CS14C15EA$ - 0
CS14C210EA$ - 0
CS14C35EA$ - 0
CS14C480EA$ - 0
CS14C52EA$ - 0
CY01Cylinders, Category 1, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12". Small (M1) = 4"x24". Medium (M2) = 12"x36". Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.CY01ME5EA$ - 0
CY01M15EA$ - 0
CY01M25EA$ - 0
CY01M35EA$ - 0
CY02Cylinders, Category 2, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12". Small (M1) = 4"x24". Medium (M2) = 12"x36". Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.CY02ME5EA$ - 0
CY02M15EA$ - 0
CY02M25EA$ - 0
CY02M35EA$ - 0
CY03Cylinders, Category 3, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12". Small (M1) = 4"x24". Medium (M2) = 12"x36". Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.CY03ME5EA$ - 0
CY03M15EA$ - 0
CY03M25EA$ - 0
CY03M35EA$ - 0
CY04Cylinders, Category 4, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12". Small (M1) = 4"x24". Medium (M2) = 12"x36". Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.CY04ME5EA$ - 0
CY04M15EA$ - 0
CY04M25EA$ - 0
CY04M35EA$ - 0
CY05Cylinders, Category 5, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12". Small (M1) = 4"x24". Medium (M2) = 12"x36". Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.CY05ME5EA$ - 0
CY05M15EA$ - 0
CY05M25EA$ - 0
CY05M35EA$ - 0
CY06Cylinders, Category 6, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12". Small (M1) = 4"x24". Medium (M2) = 12"x36". Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.CY06ME5EA$ - 0
CY06M15EA$ - 0
CY06M25EA$ - 0
CY06M35EA$ - 0
CY07Cylinders, Category 7, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12". Small (M1) = 4"x24". Medium (M2) = 12"x36". Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.CY07ME5EA$ - 0
CY07M15EA$ - 0
CY07M25EA$ - 0
CY07M35EA$ - 0
CY08Cylinders, Category 8, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x 12". Small (M1) = 4"x24". Medium (M2) = 12"x36". Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: As Appropriate to Each Gas.CY08ME5EA$ - 0
CY08M15EA$ - 0
CY08M25EA$ - 0
CY08M35EA$ - 0
CY09Cylinders, Acetylene, Contains Asbestos, for Purge and Lecture (ME) = 3"x 12". Small (M1) = 4"x24". Medium (M2) = 12"x36". Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: D001.CY09ME2EA$ - 0
CY09M12EA$ - 0
CY09M22EA$ - 0
CY09M32EA$ - 0
CY10Cylinders, Acetylene, for Recycle/Reuse. Lecture (ME) = 3"x 12". Small (M1) = 4"x24". Medium (M2) = 12"x36". Large (M3) = 16"x56".

● Physical State: Comp. Gas

● Permissible Waste Codes: D001.CY10ME20EA$ - 0
CY10M140EA$ - 0
CY10M240EA$ - 0
CY10M315EA$ - 0
CY11Cylinders, Propane, 20-Lb "Grill Size", for Disposal/Recycle/Reuse. Typically 13" x 17".

● Physical State: Comp. Gas

● Permissible Waste Codes: D001.CY11ME10EA$ - 0
CY12Cartridges, Flammable Gas, AVGAS, Gas/Diesel Starting, for Disposal/Recycle. Diameter up to 3", Length up to 10".

● Physical State: Comp. Gas

● Permissible Waste Codes: D001.CY12ME500EA$ - 0
CY13Cartridges, Inert Gas, for Disposal/Recycle/Reuse. Diameter up to 1", Length up to 6".

● Physical State: Comp. Gas

● Permissible Waste Codes: N/A.CY13ME250EA$ - 0
FL01Flammable Aerosols, Non-Foaming, No Isocyanates.

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.

FL01C720,000LB$ - 0
FL02Flammable Debris, Contaminated with Common Solvents, Shreddable, No Free Liquids, No large metal, rock, or masonry components.

● Physical State: Solid

● Permissible Waste Codes: D001, D004-43, Listed.FL02C15EA$ - 0
FL02C25EA$ - 0
FL02C35EA$ - 0
FL02C4100EA$ - 0
FL02C615EA$ - 0
FL03Flammable Liquids/Solids/Sludges/Debris, i.e. tank sludge, lubricants, paint-related waste, adhesives, rags, filters, PPE.

● Physical State: Various

● Permissible Waste Codes: D001-2, D004-43, Listed.FL03C120EA$ - 0
FL03C215EA$ - 0
FL03C390EA$ - 0
FL03C4600EA$ - 0
FL03C510EA$ - 0
FL03C615EA$ - 0
FL03B18,000LB$ - 0
FL04Flammable Corrosive Liquids/Solids/Sludges/Debris.

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D002, D004-43, Listed.FL04C11,200EA$ - 0
FL04C210EA$ - 0
FL04C320EA$ - 0
FL04C420EA$ - 0
FL04C52EA$ - 0
FL05Flammable Liquids, Pumpable, Rich, >7,000 BTU/Lb, <5% Total Chlorine.

● Physical State: Liquid

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL05C150EA$ - 0
FL05C250EA$ - 0
FL05C3150EA$ - 0
FL05C4515EA$ - 0
FL05C510EA$ - 0
FL05C630EA$ - 0
FL05B55,000GL$ - 0
FL06Flammable Liquids, Pumpable, Lean, 2,500-7,000 BTU/Lb, <5% Total Chlorine.

● Physical State: Liquid

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL06C110EA$ - 0
FL06C25EA$ - 0
FL06C35EA$ - 0
FL06C4100EA$ - 0
FL06C55EA$ - 0
FL06B52,500GL$ - 0
FL07Flammable Liquids, Pumpable, Lean to Rich, >2,500 BTU/Lb, 5-10% Total Chlorine.

● Physical State: Liquid

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL07C110EA$ - 0
FL07C210EA$ - 0
FL07C310EA$ - 0
FL07C4100EA$ - 0
FL07C55EA$ - 0
FL07B52,500GL$ - 0
FL08Flammable Resuspendable Solids/Sludges, Rich, >7,000 BTU/Lb, <5% Total Chlorine.

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL08C110EA$ - 0
FL08C26EA$ - 0
FL08C35EA$ - 0
FL08C4235EA$ - 0
FL08C520EA$ - 0
FL09Flammable Resuspendable Solids/Sludges, Lean, 2,500-7,000 BTU/Lb, <5% Total Chlorine.

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL09C15EA$ - 0
FL09C25EA$ - 0
FL09C35EA$ - 0
FL09C410EA$ - 0
FL09C51EA$ - 0
FL10Flammable Resuspendable Solids/Sludges, Lean to Rich, >2,500 BTU/Lb, 5-10% Total Chlorine.

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL10C15EA$ - 0
FL10C25EA$ - 0
FL10C35EA$ - 0
FL10C410EA$ - 0
FL10C51EA$ - 0
FL11Flammable Liquids, Highly Chlorinated (>10%), Pumpable, Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.

● Physical State: Liquid

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL11C11EA$ - 0
FL11C23EA$ - 0
FL11C32EA$ - 0
FL11C45EA$ - 0
FL11C51EA$ - 0
FL12Flammable Solids/Sludges, Highly Chlorinated (>10%), Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL12C11EA$ - 0
FL12C21EA$ - 0
FL12C32EA$ - 0
FL12C42EA$ - 0
FL12C51EA$ - 0
FL13Oxidizers, Non-Reactive, other than chromic acid (see Corrosives), Liquids/Sludges/Solids/Debris.

● Physical State: Various

● Permissible Waste Codes: D001(Oxidizer), D002, D004-43, Listed.FL13C15EA$ - 0
FL13C25EA$ - 0
FL13C35EA$ - 0
FL13C475EA$ - 0
FL13C52EA$ - 0
FL14Paints, Loose-Packed, Latex and/or Oil-Based, and Paint-Related Materials, >2,500 BTU/Lb (See Base CLIN NR06 for 100% Latex).

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL14C125EA$ - 0
FL14C225EA$ - 0
FL14C325EA$ - 0
FL14C4225EA$ - 0
FL14C53EA$ - 0
FL14C620EA$ - 0
FL15Water Contaminated with Solvents, Pumpable, <2,500 BTU/Lb.

● Physical State: Liquid

● Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL15C14EA$ - 0
FL15C25EA$ - 0
FL15C35EA$ - 0
FL15C45EA$ - 0
FL15C51EA$ - 0
FL15B52,500GL$ - 0
FL99Military Items for Demil, Flammable/Combustible/Ignitable, Inorganic Acids/Bases, with Debris and possible Free Liquids, i.e. CDE kits, loosepacks. Certificate of Disposal/Destruction Required.

● Physical State: Various

● Permissible Waste Codes: D001 (IGN), D002, D004-43, Listed.FL99C13EA$ - 0
FL99C42EA$ - 0
LP01C1Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.

● Physical State: Various

● Permissible Waste Codes: D002, D004-11, Listed Corrosives.LP01C180EA$ - 0
LP01C240EA$ - 0
LP01C320EA$ - 0
LP01C460EA$ - 0
LP01C55EA$ - 0
LP01C65EA$ - 0
LP02Lab Packs/Loose Packs, Mercury, Elemental Liquid.

● Physical State: Various

● Permissible Waste Codes: D004-11, Listed Inorganics.LP02C15EA$ - 0
LP02C15EA$ - 0
LP02C25EA$ - 0
LP02C35EA$ - 0
LP02C45EA$ - 0
LP02C51EA$ - 0
LP02C61EA$ - 0
LP03Lap Packs/Loose Packs, Flammables other than Paints.

● Physical State: Various

● Permissible Waste Codes: D001-2, D004-43, Listed Flammables.

LP03C160EA$ - 0
LP03C225EA$ - 0
LP03C315EA$ - 0
LP03C4110EA$ - 0
LP04Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, other than paints, including pharmaceuticals.

● Physical State: Various

● Permissible Waste Codes: N/A.LP04C120EA$ - 0
LP04C235EA$ - 0
LP04C330EA$ - 0
LP04C475EA$ - 0
LP04C55EA$ - 0
LP04C650EA$ - 0
LP05Lab Packs/Loose Packs, Non-Reactive Oxidizers.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D004-11, Listed.LP05C150EA$ - 0
LP05C25EA$ - 0
LP05C35EA$ - 0
LP05C45EA$ - 0
LP05C51EA$ - 0
LP05C61EA$ - 0
LP06Lab Packs/Loose Packs, Reactive Oxidizers, Includes Organic Peroxides, Special Packaging Required.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D003-11, Listed.LP06C15EA$ - 0
LP06C25EA$ - 0
LP06C35EA$ - 0
LP06C45EA$ - 0
LP06C51EA$ - 0
LP06C63EA$ - 0
LP07Lab Packs/Loose Packs, Reactive Metals, Wet/Dry, Includes Broken Sodium Lamps, Special Packaging Required.

● Physical State: Various

● Permissible Waste Codes: D001, D003-11, Listed.LP07C15EA$ - 0
LP07C25EA$ - 0
LP07C35EA$ - 0
LP07C45EA$ - 0
LP07C51EA$ - 0
LP07C62EA$ - 0
LP08Lab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing, Special Packaging Required.

● Physical State: Various

● Permissible Waste Codes: D001-43, Listed.LP08C110EA$ - 0
LP08C25EA$ - 0
LP08C32EA$ - 0
LP08C41EA$ - 0
LP08C51EA$ - 0
LP08C61EA$ - 0
LP09Lab Packs/Loose Packs, Toxic Metals.

● Physical State: Various

● Permissible Waste Codes: D004-11, Listed Inorganics.LP09C110EA$ - 0
LP09C25EA$ - 0
LP09C35EA$ - 0
LP09C45EA$ - 0
LP09C51EA$ - 0
LP09C61EA$ - 0
LP10Lab Packs/Loose Packs, Toxic Organics.

● Physical State: Various

● Permissible Waste Codes: D004-43, Listed.LP10C110EA$ - 0
LP10C22EA$ - 0
LP10C32EA$ - 0
LP10C45EA$ - 0
LP10C51EA$ - 0
LP10C63EA$ - 0
LP11Lab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, including pharmaceuticals.

● Physical State: Various

● Permissible Waste Codes: D004-43, P-Listed Codes.LP11C12EA$ - 0
LP11C22EA$ - 0
LP11C32EA$ - 0
LP11C42EA$ - 0
LP11C51EA$ - 0
LP11C61EA$ - 0
LP12Lab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals.

● Physical State: Various

● Permissible Waste Codes: D004-43, U-Listed Codes.LP12C15EA$ - 0
LP12C25EA$ - 0
LP12C35EA$ - 0
LP12C45EA$ - 0
LP12C51EA$ - 0
LP12C63EA$ - 0
NR01Non-RCRA Solids, Direct Landfill Ready (Subtitle D or Equivalent). No Free Liquids. Includes Non-PCB Drained/Dry Transformers, Ballasts, Capacitors, and Related Equipment.

● Physical State: Solid

● Permissible Waste Codes: N/A.NR01C120EA$ - 0
NR01C210EA$ - 0
NR01C320EA$ - 0
NR01C41,000EA$ - 0
NR01C510EA$ - 0
NR01C6250EA$ - 0
NR01B1350,000LB$ - 0
NR01B2500,000LB$ - 0
NR01B3500,000LB$ - 0
NR01B4300,000LB$ - 0
NR01B6450CD$ - 0
NR02Non-RCRA Solids with Asbestos, Direct Landfill Ready (Subtitle D or Equivalent). Special Packaging Required. No Free Liquids.

● Physical State: Solid

● Permissible Waste Codes: N/A.NR02C15EA$ - 0
NR02C25EA$ - 0
NR02C35EA$ - 0
NR02C410EA$ - 0
NR02C52EA$ - 0
NR02C62EA$ - 0
NR03Non-RCRA Liquids, Pumpable, Aqueous (Water-Based).

● Physical State: Liquid

● Permissible Waste Codes: N/A.NR03C15EA$ - 0
NR03C23EA$ - 0
NR03C35EA$ - 0
NR03C485EA$ - 0
NR03C55EA$ - 0
NR03B54,000GL$ - 0
NR04Non-RCRA Liquids, Pumpable, Organic-Based.

● Physical State: Liquid

● Permissible Waste Codes: N/A.NR04C120EA$ - 0
NR04C225EA$ - 0
NR04C335EA$ - 0
NR04C4140EA$ - 0
NR04C52EA$ - 0
NR04B54,000GL$ - 0
NR05Non-RCRA Sludges/Solids/Debris with Free Liquids. Includes Non-PCB Oil-Filled Transformers, Ballasts, Capacitors and Related Equipment.

● Physical State: Various

● Permissible Waste Codes: N/A.NR05C125EA$ - 0
NR05C225EA$ - 0
NR05C325EA$ - 0
NR05C41,200EA$ - 0
NR05C5100EA$ - 0
NR05B19,000LB$ - 0
NR06Non-RCRA Loose-Packed Paints, 100% Water-Based (Latex).

● Physical State: Various

● Permissible Waste Codes: N/A.NR06C150EA$ - 0
NR06C250EA$ - 0
NR06C350EA$ - 0
NR06C4500EA$ - 0
NR06C515EA$ - 0
NR06C625EA$ - 0
NR08Non-RCRA (RCRA-Empty) Containers, Metal & Plastic/Poly, Crushed, Recycle or Disposal.

● Physical State: Solid

● Permissible Waste Codes: N/A.NR08B15,000LB$ - 0
NR96Non-RCRA Liquids, Pumpable, for RCRA Incineration. Certificate of Disposal/Destruction Required.

● Physical State: Liquid

● Permissible Waste Codes: N/A.NR96C15EA$ - 0
NR96C25EA$ - 0
NR96C35EA$ - 0
NR96C410EA$ - 0
NR96C52EA$ - 0
NR98Non-RCRA Military Articles, Demil-Required, i.e. Boots, Gloves, CDE Kits, Filters, Masks, MOPP Suits, etc. for Subtitle D or Subtitle C Landfill, or Thermal Destruction. Certificate of Disposal/Destruction Required. No Uniforms (Use NR99) or Submarine Tiles (Use TX99).

● Physical State: Various

● Permissible Waste Codes: N/A.NR98C715,000LB$ - 0
NR99Non-RCRA Military Textiles for Demil, i.e. Uniforms, via Thermal Destruction. Certificate of Destruction Required.

● Physical State: Solid

● Permissible Waste Codes: N/A.NR99C725,000LB$ - 0
PC01PCB and PCB/RCRA-Mixed Waste Contaminated with or Containing >50 ppm Source, i.e. Debris, Sludge, Water, Leaking Capacitors, Fluids other than Transformer Mineral Oil. Certificate of Destruction Required.

● Physical State: Various

● Permissible Waste Codes: Characteristic, Listed.PC01C7150LB$ - 0
PC02PCB Mineral Oil from Transformers, 1-49 ppm PCBs, Non-RCRA.

● Physical State: Liquid

● Permissible Waste Codes: N/A.PC02C7150LB$ - 0
PC03PCB Mineral Oil from Transformers, 50-4,000 ppm PCBs. Non-RCRA, Certificate of Recycling or Destruction Required.

● Physical State: Liquid

● Permissible Waste Codes: N/A.PC03C7150LB$ - 0
PC04PCB Mineral Oil , Water, Other Fluids, >4,000 ppm PCBs. Certificate of Destruction Required.

● Physical State: Liquid

● Permissible Waste Codes: Characteristic, Listed.PC04C7150LB$ - 0
PC05PCB Oil-Filled Capacitors/Equipment other than Transformers, 1-49 ppm PCBs, Non-RCRA.

● Physical State: Various

● Permissible Waste Codes: N/A.PC05C7150LB$ - 0
PC06PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, >50 ppm PCBs, Non-RCRA, Certificate of Recycling or Destruction Required.

● Physical State: Various

● Permissible Waste Codes: N/A.PC06C7200LB$ - 0
PC07PCB Oil-Filled Transformers, 1-49 ppm PCBs, Non-RCRA.

● Physical State: Various

● Permissible Waste Codes: N/A.PC07C7150LB$ - 0
PC08PCB Oil-Filled Transformers, >50 ppm PCBs. Certificate of Recycling or Destruction Required.

● Physical State: Various

● Permissible Waste Codes: N/A.PC08C7150LB$ - 0
PC09PCB Solids/Debris Contaminated with 1-49 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non-RCRA.

● Physical State: Solid

● Permissible Waste Codes: N/A.PC09C7150LB$ - 0
PC10PCB Solids/Debris Contaminated with >50 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Non-RCRA. Certificate of Disposal, Recycling or Destruction Required.

● Physical State: Solid

● Permissible Waste Codes: N/A.PC10C7500LB$ - 0
RE01Lamps, Fluorescent, Intact. CFLs and <4 ft = Each (ME). U-Bent, Circulars, and 4-6 ft. linears = Small (M1). 6-8 ft. = Medium (M2). >8 ft. = Large (M3).

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D004-11.RE01ME5,000EA$ - 0
RE01M150,000EA$ - 0
RE01M225,000EA$ - 0
RE01M32,000EA$ - 0
RE02Lamps, Fluorescent, Crushed/Broken, with Filters.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D004-11.RE02C125EA$ - 0
RE02C225EA$ - 0
RE02C325EA$ - 0
RE02C4150EA$ - 0
RE03Lamps, Halogen.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D004-11.RE03ME500EA$ - 0
RE04Lamps, High Intensity Discharge (HID).

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D004-12.RE04ME500EA$ - 0
RE05Lamps, Mercury/Mercury Vapor.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste, D004-13.RE05ME500EA$ - 0
RE06Lamps, Metal Halide and Metal Hydride, including Sodium.

● Physical State: Solid

● Permissible Waste Codes: Universal Waste D003-11.RE06ME500EA$ - 0
RE07Mercury, High, COD Vials, Nessler's Reagent, Chemicals and Residues, Hg >260 mg/Kg.

● Physical State: Various

● Permissible Waste Codes: D002, D004-11, UW some states.RE07C13EA$ - 0
RE07C23EA$ - 0
RE07C33EA$ - 0
RE07C43EA$ - 0
RE07C51EA$ - 0
RE08Mercury, High, Dental Amalgams & Residues, Hg >260 mg/Kg.

● Physical State: Various

● Permissible Waste Codes: D004-11, UW in some states.RE08C12EA$ - 0
RE08C22EA$ - 0
RE09Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg >260 mg/Kg.

● Physical State: Various

● Permissible Waste Codes: Universal Waste, D004-11.RE09C110EA$ - 0
RE09C22EA$ - 0
RE09C32EA$ - 0
RE09C45EA$ - 0
RE10Antifreeze, Used and Unused for Recycling or Fuels Blending. RE10ME refers to 55-gal containers pumped/vacuumed/stung onsite and includes recycling and service.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, UW in some states.RE10C115EA$ - 0
RE10C215EA$ - 0
RE10C315EA$ - 0
RE10C4500EA$ - 0
RE10C550EA$ - 0
RE10B55,000GL$ - 0
RE10ME220EA$ - 0
RE11Used Oil, <10% Water, <1,000 ppm Total Organic Halides. RE11ME refers to 55-gal containers pumped/vacuumed/stung onsite and includes recycling and service.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, UW in some states.RE11C15EA$ - 0
RE11C25EA$ - 0
RE11C35EA$ - 0
RE11C4100EA$ - 0
RE11C55EA$ - 0
RE11B55,000GL$ - 0
RE11ME650EA$ - 0
RE12Used Oil, >10% Water, <1,000 ppm Total Organic Halides. RE12ME refers to 55-gal containers pumped/vacuumed/stung onsite and includes recycling and service.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, UW in some states.RE12C15EA$ - 0
RE12C25EA$ - 0
RE12C35EA$ - 0
RE12C4250EA$ - 0
RE12C520EA$ - 0
RE12B55,000GL$ - 0
RE12ME250EA$ - 0
RE13Used Oil Filters, Drained and Undrained, and/or Fully Drained Fuel Filters.

● Physical State: Various

● Permissible Waste Codes: D004-11, UW in some states.RE13C15EA$ - 0
RE13C25EA$ - 0
RE13C35EA$ - 0
RE13C4250EA$ - 0
RE13C520EA$ - 0
RE13C625EA$ - 0
RE14C1Lead Articles and Spent Ammunitions Meeting Specs for Recovery.

● Physical State: Solid

● Permissible Waste Codes: D004-11, UW in some states.RE14C15EA$ - 0
RE14C25EA$ - 0
RE14C35EA$ - 0
RE14C475EA$ - 0
RX01Aerosols, Foaming, Isocyanates or other reactives.

● Physical State: Various

● Permissible Waste Codes: D001, D003, D004-43, Listed.

RX01C72,500LB$ - 0
RX02Cyanide, >50% Debris, >590 mg/Kg Total CN.

● Physical State: Various

● Permissible Waste Codes: D002-11, Listed.RX02C12EA$ - 0
RX02C22EA$ - 0
RX02C32EA$ - 0
RX02C42EA$ - 0
RX02C51EA$ - 0
RX04Cyanide Liquids, Solids, <50% Debris, 1%-10% Total CN.

● Physical State: Various

● Permissible Waste Codes: D002-11, Listed.RX04C12EA$ - 0
RX04C22EA$ - 0
RX04C33EA$ - 0
RX04C42EA$ - 0
RX04C51EA$ - 0
RX06Oxidizers, i.e. Nitrates, Nitrites, Persulfates, Inorganic Peroxides, No Organic Peroxides.

● Physical State: Various

● Permissible Waste Codes: D001, D003, D004-11, Listed.RX06C13EA$ - 0
RX06C23EA$ - 0
RX06C33EA$ - 0
RX06C43EA$ - 0
RX06C51EA$ - 0
RX08Reactive Metals, i.e. Powders, Dusts, Fines. Air/Water Reactive. Shipped Under Oil and/or Special Packaging.

● Physical State: Solid

● Permissible Waste Codes: D001, D003, D004-11, Listed.RX08C110EA$ - 0
RX08C23EA$ - 0
RX08C33EA$ - 0
RX08C43EA$ - 0
RX08C51EA$ - 0
RX10Reactives, Non-Metals, i.e. P-Coded, Temperature Sensitive, PIHs, Air/Water Reactive.

● Physical State: Various

● Permissible Waste Codes: D001, D003, D004-11, Listed.RX10C13EA$ - 0
RX10C23EA$ - 0
RX10C33EA$ - 0
RX10C43EA$ - 0
RX10C51EA$ - 0
RX98OBA Canisters, Reactive, Spent and/or Unspent. Special packaging may be required.

● Physical State: Solid

● Permissible Waste Codes: D001, D003, D004-11.RX98C45EA$ - 0
RX98C51EA$ - 0
RX99Military Articles for Demil, Reactive, i.e. CDE Kits, Filters, loosepacks, etc. via RCRA Incineration. Does not include OBA/SCBA Canisters. Certificate of Disposal/Destruction Required.

● Physical State: Various

● Permissible Waste Codes: D001-D043, Listed.RX99C15EA$ - 0
RX99C25EA$ - 0
RX99C35EA$ - 0
RX99C45EA$ - 0
RX99C55EA$ - 0
TX01Chromium, Hexavalent, <1% Cr+6, Characteristic Liquids, Solids, Sludges.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D004-11.TX01C15EA$ - 0
TX01C25EA$ - 0
TX01C35EA$ - 0
TX01C45EA$ - 0
TX01C51EA$ - 0
TX03Chromium, Hexavalent, >10% Cr+6, Characteristic Liquids, Solids, Sludges.

● Physical State: Various

● Permissible Waste Codes: D001 (Oxidizer), D004-11.TX03C14EA$ - 0
TX03C33EA$ - 0
TX03C42EA$ - 0
TX04Chromium, Hexavalent, <1% Cr+6, Listed Liquids, Solids, Sludges.

● Physical State: Various

● Permissible Waste Codes: D004-11, F006-12, F019.TX04C15EA$ - 0
TX04C25EA$ - 0
TX04C35EA$ - 0
TX04C45EA$ - 0
TX04C51EA$ - 0
TX05Chromium, Hexavalent, Wastewater, Pumpable, <1% Total Metals.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, Listed Inorganics.TX05C12EA$ - 0
TX05C32EA$ - 0
TX05C42EA$ - 0
TX05B52,500GL$ - 0
TX06Debris, Inorganic Constituents Only. >50% debris by volume, >60 mm (~2.5") particle size. No free liquids unless incidental rainwater/condensation (See TX20).

● Physical State: Debris

● Permissible Waste Codes: D004-11, Listed Inorganics.TX06C158EA$ - 0
TX06C25EA$ - 0
TX06C3200EA$ - 0
TX06C4750EA$ - 0
TX06C6125EA$ - 0
TX06B1100,000LB$ - 0
TX06B2200,000LB$ - 0
TX06B3150,000LB$ - 0
TX06B4150,000LB$ - 0
TX06B61,000CD$ - 0
TX07Debris, Organic and/or Inorganic Constituents. >50% Debris by volume, >60 mm (~2.5") Particle size. No free liquids unless incidental rainwater/condensation (See TX20).

● Physical State: Debris

● Permissible Waste Codes: D004-43, Listed, but no F020-32.TX07C125EA$ - 0
TX07C275EA$ - 0
TX07C375EA$ - 0
TX07C4200EA$ - 0
TX07B110,000LB$ - 0
TX07B210,000LB$ - 0
TX07B320,000LB$ - 0
TX09High Halogen Liquids/Sludges/Solids/Debris, Non-Flammable, Includes Solvents, Herbicides and Pesticides, Characteristic/Listed.

● Physical State: Various

● Permissible Waste Codes: D004-43, Listed.TX09C15EA$ - 0
TX09C25EA$ - 0
TX09C35EA$ - 0
TX09C415EA$ - 0
TX09B5500GL$ - 0
TX10Metals in Wastewater, <5% Suspended Solids, <1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/Listed.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, Listed Inorganics.TX10C120EA$ - 0
TX10C25EA$ - 0
TX10C35EA$ - 0
TX10C420EA$ - 0
TX10C55EA$ - 0
TX10B5500GL$ - 0
TX11Metals in Wastewater, <5% Suspended Solids, >1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/Listed.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, Listed Inorganics.TX11C110EA$ - 0
TX11C25EA$ - 0
TX11C35EA$ - 0
TX11C410EA$ - 0
TX11C51EA$ - 0
TX11B5500GL$ - 0
TX12Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Characteristic.

● Physical State: Liquid

● Permissible Waste Codes: D004-11.TX12C12EA$ - 0
TX12C22EA$ - 0
TX12C310EA$ - 0
TX12C4115EA$ - 0
TX12C54EA$ - 0
TX12B521,250GL$ - 0
TX13Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Listed.

● Physical State: Liquid

● Permissible Waste Codes: D004-11, Listed.TX13C12EA$ - 0
TX13C22EA$ - 0
TX13C32EA$ - 0
TX13C45EA$ - 0
TX13C51EA$ - 0
TX13B510,000GL$ - 0
TX14Metals-Bearing Liquids, High, >1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Pumpable if Bulk, Characteristic.

● Physical State: Liquid

● Permissible Waste Codes: D004-11.TX14C11EA$ - 0
TX14C21EA$ - 0
TX14C31EA$ - 0
TX14C42EA$ - 0
TX14C51EA$ - 0
TX16Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic.

● Physical State: Various

● Permissible Waste Codes: D004-11.TX16C12EA$ - 0
TX16C22EA$ - 0
TX16C317EA$ - 0
TX16C4300EA$ - 0
TX16C54EA$ - 0
TX16C6250EA$ - 0
TX16B150,000LB$ - 0
TX16B2200,000LB$ - 0
TX16B31,000,000LB$ - 0
TX16B4200,000LB$ - 0
TX17Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Listed.

● Physical State: Various

● Permissible Waste Codes: D004-11, Listed.TX17C21EA$ - 0
TX17C328EA$ - 0
TX17C45EA$ - 0
TX18Metals-Bearing Solids/Sludges/Some Free Liquids, High (>1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic.

● Physical State: Various

● Permissible Waste Codes: D004-11.TX18C332EA$ - 0
TX18C414EA$ - 0
TX18B18,000LB$ - 0
TX18B222,000LB$ - 0
TX19Metals-Bearing Solids/Sludges/Some Free Liquids, High (>1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, Listed.

● Physical State: Various

● Permissible Waste Codes: D004-11, Listed.TX19C45EA$ - 0
TX19C51EA$ - 0
TX20Metals-Bearing Debris/Solids/Sludges with Free Liquids, Total Cr+6 <100 ppm, Total Hg <260 ppm, Characteristic/Listed.

● Physical State: Various

● Permissible Waste Codes: D004-11, Listed.TX20C4525EA$ - 0
TX20C53EA$ - 0
TX22Organics in Solids/Sludges/Debris, i.e. Soil, Tank & Still Bottoms, Adhesives, Filtercake. Not more toxic than common solvents.

● Physical State: Various

● Permissible Waste Codes: D004-43, Listed.TX22C23EA$ - 0
TX22C31EA$ - 0
TX22C432EA$ - 0
TX22C6200EA$ - 0
TX22B115,000LB$ - 0
TX22B250,000LB$ - 0
TX22B350,000LB$ - 0
TX22B470,000LB$ - 0
TX23Toxic/Hazardous Solids and Debris Meeting Universal Treatment Standards (UTS). Subtitle C Landfill Ready. No Free Liquids or PCBs.

● Physical State: Solid

● Permissible Waste Codes: Listed.TX23C45EA$ - 0
TX23B1100,000LB$ - 0
TX23B2100,000LB$ - 0
TX23B3100,000LB$ - 0
TX97Toxic Electron Tubes for Demil and Disposal, Intact, Certificate of Disposal/Destruction Required.

● Physical State: Solid

● Permissible Waste Codes: D004-11.TX97C15EA$ - 0
TX97C25EA$ - 0
TX97C35EA$ - 0
TX97C45EA$ - 0
TX97C62EA$ - 0
TX98Military Items, Demil-required, RCRA Toxic, i.e. CDE Kits, Tents, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. Certificate of Disposal/Destruction Required.

● Physical State: Various

● Permissible Waste Codes: D004-43, Listed.TX98C310EA$ - 0
TX98C415EA$ - 0

Note: The Base CLIN followed by the CLIN Suffix collectively comprise the entire CLIN. "Permissible Waste Codes" does not imply that any or all of those waste codes referenced will apply, but no other waste codes may apply. The term "Listed" does not imply that all USEPA Listed Waste Codes may apply. Rare/exotic listed waste codes or combinations thereof may be handled on a case-by-case basis, with consideration given to those Waste Codes that are Permitted and accepted by the TSD Facilities and their geographic locations. 18 Mo Total

1st OP

Anniston Army Depot/Redstone Arsenal Regional Disposal Contract - 1ST OP
Base
CLINWaste DescriptionCLINEst. QtyU/IPriceExtended Price
6000 Series CLINs
6310AAProvide metal containers with lids for repackaging, 55-gallon to 85-gallon size, meeting DOT requirements.6310AA5EA$ - 0
6311AAProvide service to place waste in containers - up to one 5 gal container.6311AA5EA$ - 0
6312C2Provide container, 5 gal, UN 1H2/Y30/S open screw-top plastic pail with locking lid, new.6312C2100EA$ - 0
6312C3Provide x100 containers, 5 gal Poly w/ screw-top lid, 1H2/Y27, (1 EA = Qty 100).6312C32EA$ - 0
6312C4Provide x100 containers, 5 gal poly, tight head, rectangular body, w/o caps, (1 EA = Qty 100).6312C42EA$ - 0
6312D1Provide container, 15 gal, UN 1H2/Y100/S open head, plastic, new.6312D1100EA$ - 0
6312D3Provide x200 containers, 15 gal steel, open top, plain lid, new, (1 EA = Qty 200).6312D31EA$ - 0
6312D4Provide x100 quick release rings to fit CLIN 6312D3 (1 EA = Qty 100).6312D42EA$ - 0
6312F2Provide container, 30 gal. UN 1H2/Y open top, plastic, new.6312F2150EA$ - 0
6312F6Provide x200 containers, 30 gal steel, open top, new, UN 1A1/X1.3/300 (1 EA = Qty 200).6312F61EA$ - 0
6312F7Provide x100 quick relase rings to fit CLIN 6312F6 (1 EA = Qty 100).6312F72EA$ - 0
6312GAProvide x50 containers, 55 gal steel, open top, bung lid, new or reconditioned, UN 1A2/Y1.2/100 (1 EA = qty 50).6312GA1EA$ - 0
6312GBProvide x50 quick release rings to fit CLIN 6312GA (1 EA = qty 50).6312GB1EA$ - 0
6312GDProvide x50 containers, 55 gal steel, closed top, new or reconditioned, 1A1/X1.4/300 (1 EA = qty 50).6312GD2EA$ - 0
6312GEProvide x50 containers, 55 gal poly, tight head, new, 1H1/Y1.8/100 (1 EA = Qty 50).6312GE2EA$ - 0
6312J3Provide 300 pallets, reconditioned acceptable, to fit CLIN 6312K3 (1 EA = Qty 300).6312J32EA$ - 0
6312K3Provide x200 one-cubic-yard boxes, tri-walled corrugated cardboard, w/ straps, liners, and nails, UN11G/X/ (1 EA = 200).6312K32EA$ - 0
6312M3Provide x20 fluorescent tube drums, 8-ft fiber, UN (1 EA = Qty 20).6312M310EA$ - 0
6312M4Provide x20 fluorescent tube drums, 4-ft fiber, UN 1G/Y50/S (1 EA = Qty 20).6312M410EA$ - 0
6318Tote Return Surcharge, for return of empty Government-owned totes up to 330-gal. Ordered in addition to bulk disposal CLIN.631840EA$ - 0
6320Provide and prepare lab packs, consisting of small quantity chemicals (56-85 gal) (See 3.7).632010EA$ - 0
6321Provide and prepare lab packs, consisting of small quantity chemicals (55 gal) (See 3.7).6321110EA$ - 0
6322Provide and prepare lab packs, consisting of small quantity chemicals (20-30 gal) (See 3.7).63225EA$ - 0
6323Provide and prepare lab packs, consisting of small quantity chemicals (5-15 gal) (See 3.7).632375EA$ - 0
6330Expedited removal - 15 days (See 1.2.11).63302EA$ - 0
6331Expedited removal - 10 days (See 1.2.11).63312EA$ - 0
6332Expedited removal - 7 days (See 1.2.11).63323EA$ - 0
6333Expedited removal - 5 days (See 1.2.11).63335EA$ - 0
6334Expedited removal - 3 days (See 1.2.11).63345EA$ - 0
6335Expedited removal - 1 day (See 1.2.11).633515EA$ - 0
6340Expedited performance - 15 days (See 1.2.11).63405EA$ - 0
6341Expedited performance - 10 days (See 1.2.11).63415EA$ - 0
6342Expedited performance - 7 days (See 1.2.11).63425EA$ - 0
6343Expedited performance - 5 days (See 1.2.11).63435EA$ - 0
6344Expedited performance - 3 days (See 1.2.11).63445EA$ - 0
6345Expedited performance - 1 day (See 1.2.11).634515EA$ - 0
6350AATank cleaning/services – above ground, 1 to 999 gallon capacity (See 3.2).6350AA25EA$ - 0
6350BBTank cleaning/cervices – above ground, 1,000 to 3,000 gal capacity (See 3.2).6350BB125EA$ - 0
6350CCTank cleaning/services – above ground, 3,001 to 6,000 gal capacity (See 3.2).6350CC5EA$ - 0
6350DDTank cleaning/services – above ground, 6,001 to 12,000 gal capacity (See 3.2).6350DD5EA$ - 0
6351AATank cleaning/services – below ground, 1 to 999 gal capacity (See 3.2).6351AA20EA$ - 0
5351BBTank cleaning/services – below ground, 1,000 to 3,000 gal capacity (See 3.2).5351BB5EA$ - 0
6351CCTank cleaning/services – below ground, 3,001 to 6,000 gal capacity (See 3.2).6351CC5EA$ - 0
6351PCCleanout of Lagoons at ANAD [See 3.12].6351PC2EA$ - 0
6352AATank cleaning/services – oil/water separator, 1 to 999 gal capacity (See 3.2).6352AA15EA$ - 0
6352BBTank cleaning/services – oil/water separator, 1,000 to 3,000 gal capacity (See 3.2).6352BB15EA$ - 0
6352CCTank cleaning/services – oil/water separator, 3,001 to 6,000 gal capacity (See 3.2).6352CC15EA$ - 0

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .