(11)_Attachment_K_Project_Specifications_and_Submittals.pdf

PDF 18 MB Posted

Attached to
Building 81 Renovation Federal contract opportunity
Solicitation number
SP3300-16-B-0012
Issued by
Defense Logistics Agency Distribution

About this file

Attachment 11 to IFB

View the file

Other files for this federal contract opportunity

Other files attached to Building 81 Renovation, newest first.
File Type Posted
SP3300-16-B-0012_Bid_Abstract.pdf PDF
Amendment_0006_Revised_spec_section_26_24_13_Switchboards.pdf PDF
Amendment_0006.pdf PDF
Amendment_0005.pdf PDF
Amendment_0005_Revised_Drawings.pdf PDF
Amendment_0004_Revised_Drawings.pdf PDF
Amendment_0004.pdf PDF
Amendment_0004_Revised_SPEC_25_10_10.pdf PDF
(11A)_Attachment_Amendment_0003_Revised_Project_Specifications.pdf PDF
Amendment_0003.pdf PDF
(12A)_Attachment_Amendment_0003_Revised_Drawings.pdf PDF
(10)_Revised_Attachment_J_Wage_Determinations.pdf PDF
Revised_SP3300-16-B-0012.pdf PDF
Amendment_0002_Posted_to_FBO_08262016.pdf PDF
Amendment_0001.pdf PDF
Site_Visit_Attendance_Sheet.pdf PDF
Site_Visit_Notes.pdf PDF
(3)_Attachment_C_Long_Form_Badge_Request.pdf PDF
(7)_Attachment_G_SF24_-_Bid_Bond.pdf PDF
SP3300-16-B-0012.pdf PDF
(8)_Attachment_H_SF25_(Performance_Bond).pdf PDF
(1)_Attachment_A_New_Personnel_Notification_Form.docm DOCM document
(12)_Attachment_L_Drawings.pdf PDF
(9)_Attachment_I_SF25A_(Payment_Bond).pdf PDF
(6)_Attachment_F_DLA_SP_Camera_Pass_Request_Form.pdf PDF
(2)_Attachment_B_Short_Form_Badge_Request.pdf PDF
(10)_Attachment_J_Wage_Determinations.pdf PDF
(4)_Attachment_D_Badge_Renewal.doc DOC document
(5)_Attachment_E_Deliv_Notification_Form.docm DOCM document
Show all 29

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W912HP-15-D-0004

SPECIFICATIONS

Volume 1 - Divisions 00 - 12

June 3, 2016

This page was intentionally left blank for duplex printing.

Building 81 Renovation JUNE 2016 Defense Distribution Center Susquehanna, New Cumberland, PA

PROJECT TABLE OF CONTENTS

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

00 31 00 AVAILABLE PROJECT INFORMATION

00 31 02 LEED CHECKLIST

00 43 22 UNIT PRICES

DIVISION 01 - GENERAL REQUIREMENTS

01 11 00 SUMMARY OF WORK

01 14 00 WORK RESTRICTIONS

01 32 01.00 10 PROJECT SCHEDULE

01 33 00 SUBMITTAL PROCEDURES

01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS

01 35 40.00 20 ENVIRONMENTAL MANAGEMENT

01 42 00 SOURCES FOR REFERENCE PUBLICATIONS

01 45 00.10 20 QUALITY CONTROL FOR MINOR CONSTRUCTION

01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS

01 57 19.00 20 TEMPORARY ENVIRONMENTAL CONTROLS

01 57 20.00 10 ENVIRONMENTAL PROTECTION

01 62 35 RECYCLED / RECOVERED MATERIALS

01 74 19 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT

01 78 00 CLOSEOUT SUBMITTALS

01 78 23 OPERATION AND MAINTENANCE DATA

DIVISION 02 - EXISTING CONDITIONS

02 41 00 DEMOLITION

02 42 51 CARPET REMOVAL AND RECLAMATION

02 84 16 HANDLING OF LIGHTING BALLASTS AND LAMPS CONTAINING PCBs

AND MERCURY

02 85 00.00 20 MOLD REMEDIATION

DIVISION 03 - CONCRETE

03 30 53 MISCELLANEOUS CAST-IN-PLACE CONCRETE

03 45 00 PRECAST ARCHITECTURAL CONCRETE

DIVISION 05 - METALS

05 12 00 STRUCTURAL STEEL

05 30 00 STEEL DECKS

05 50 13 MISCELLANEOUS METAL FABRICATIONS

05 52 00 METAL RAILINGS

DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES

06 10 00 ROUGH CARPENTRY

06 20 00 FINISH CARPENTRY

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

07 13 53 ELASTOMERIC SHEET WATERPROOFING

07 21 16 MINERAL FIBER BLANKET INSULATION

07 22 00 ROOF AND DECK INSULATION

07 24 00 EXTERIOR INSULATION AND FINISH SYSTEMS

07 60 00 FLASHING AND SHEET METAL

07 61 14.00 20 STEEL STANDING SEAM ROOFING

PROJECT TABLE OF CONTENTS Page 1

07 84 00 FIRESTOPPING

07 92 00 JOINT SEALANTS

DIVISION 08 - OPENINGS

08 11 13 STEEL DOORS AND FRAMES

08 11 16 ALUMINUM DOORS AND FRAMES

08 14 00 WOOD DOORS

08 41 13 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

08 71 00 DOOR HARDWARE

08 81 00 GLAZING

08 91 00 METAL WALL LOUVERS

DIVISION 09 - FINISHES

09 05 61 COMMON WORK RESULTS FOR FLOORING PREPARATION

09 22 00 SUPPORTS FOR GYPSUM BOARD

09 29 00 GYPSUM BOARD

09 51 00 ACOUSTICAL CEILINGS

09 65 00 RESILIENT FLOORING BASE AND TRANSITIONS

09 68 00 CARPETING

09 90 00 PAINTS AND COATINGS

DIVISION 10 - SPECIALTIES

10 14 10.00 10 MECHANICAL SIGNAGE

10 14 20.00 10 FIRE PROTECTION SYSTEM SIGNAGE

10 44 16 FIRE EXTINGUISHERS

DIVISION 12 - FURNISHINGS

12 21 00 WINDOW BLINDS

DIVISION 21 - FIRE SUPPRESSION

21 13 13.00 10 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION

DIVISION 22 - PLUMBING

22 00 00 PLUMBING, GENERAL PURPOSE

DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)

23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS

23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC

23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS

23 08 00.00 10 COMMISSIONING OF HVAC SYSTEMS

23 09 00 INSTRUMENTATION AND CONTROL FOR HVAC

23 09 23.01 LONWORKS DIRECT DIGITAL CONTROL FOR HVAC AND OTHER

BUILDING CONTROL SYSTEMS

23 11 25 FACILITY GAS PIPING

23 25 00 CHEMICAL TREATMENT OF WATER FOR MECHANICAL SYSTEMS

23 52 00 HEATING BOILERS

23 64 10 WATER CHILLERS, VAPOR COMPRESSION TYPE

23 64 26 CHILLED, CHILLED-HOT, AND CONDENSER WATER PIPING SYSTEMS

DIVISION 26 - ELECTRICAL

26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS

PROJECT TABLE OF CONTENTS Page 2

26 08 00 APPARATUS INSPECTION AND TESTING

26 12 19.10 THREE-PHASE PAD-MOUNTED TRANSFORMERS

26 20 00 INTERIOR DISTRIBUTION SYSTEM

26 24 13 SWITCHBOARDS

26 28 01.00 10 COORDINATED POWER SYSTEM PROTECTION

26 29 23 VARIABLE FREQUENCY DRIVE SYSTEMS UNDER 600 VOLTS

26 36 00.00 10 AUTOMATIC TRANSFER SWITCH AND BY-PASS/ISOLATION SWITCH

26 51 00 INTERIOR LIGHTING

26 56 00 EXTERIOR LIGHTING

DIVISION 27 - COMMUNICATIONS

27 05 14.00 10 CABLE TELEVISION PREMISES DISTRIBUTION SYSTEM

27 05 29.00 10 PROTECTIVE DISTRIBUTION SYSTEM (PDS) FOR SIPRNET

COMMUNICATION SYSTEMS

27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM

DIVISION 28 - ELECTRONIC SAFETY AND SECURITY

28 16 01.00 10 SMALL INTRUSION DETECTION SYSTEM

28 20 01.00 10 ELECTRONIC SECURITY SYSTEM

28 31 49 CARBON MONOXIDE DETECTORS

28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM

DIVISION 31 - EARTHWORK

31 00 00 EARTHWORK

31 11 00 CLEARING AND GRUBBING

31 31 16.13 CHEMICAL TERMITE CONTROL

DIVISION 32 - EXTERIOR IMPROVEMENTS

32 05 33 LANDSCAPE ESTABLISHMENT

32 10 00 BITUMINOUS CONCRETE PAVEMENT

32 11 23 AGGREGATE BASE COURSE

32 12 10 BITUMINOUS TACK AND PRIME COATS

32 16 13 CONCRETE SIDEWALKS AND CURBS

32 17 23.00 20 PAVEMENT MARKINGS

32 92 19 SEEDING

DIVISION 33 - UTILITIES

33 11 00 WATER DISTRIBUTION

33 40 00 STORM DRAINAGE UTILITIES

33 46 13 FOUNDATION DRAINAGE SYSTEM

33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION

-- End of Project Table of Contents --

PROJECT TABLE OF CONTENTS Page 3

CERTIFICATIONS

00 01 05 - 1

SECTION 00 01 05

I hereby certify that the architectural portions of work included in these plans and specifications, except as otherwise indicated by other registered professionals, have been prepared by me or under my direct supervision, and that I have coordinated the architectural portions with those portions sealed by other registered professionals.

Greg B. Cockmon, AIA, Architect Principal

CROMWELL ARCHITECTS

ENGINEERS, INC.

Architects Engineers 101 S. Spring Street Little Rock, Arkansas

03 June 2016 Date

I hereby certify that the civil portions of work included in these plans and specifications, except as otherwise indicated, have been prepared by me, or under my direct supervision.

John Petersen, PE Civil Engineer

CROMWELL ARCHITECTS

ENGINEERS, INC.

Architects Engineers 101 S. Spring Street Little Rock, Arkansas

I hereby certify that fire protection portions of work included in these plans and specifications, except as otherwise

Brian Gerdwagen, FPE Fire Protection Engineer

CROMWELL ARCHITECTS

ENGINEERS, INC.

Architects Engineers 101 S. Spring Street Little Rock, Arkansas

00 01 05 - 2

I hereby certify that the mechanical portions of work included in these plans and specifications, except as otherwise

Robert L. Seay, PE, Mechanical Engineer Principal

CROMWELL ARCHITECTS

ENGINEERS, INC.

Architects Engineers 101 S. Spring Street Little Rock, Arkansas

I hereby certify that the electrical portions of work included in these plans and specifications, except as otherwise

Brent L. Hamling, PE Electrical Engineer

CROMWELL ARCHITECTS

ENGINEERS, INC.

Architects Engineers 101 S. Spring Street Little Rock, Arkansas

00 01 05 - 1

I hereby certify that the communication portions of work included in these plans and specifications, except as otherwise

Donnie Jones, PE, RCDD Electrical Engineer

Donnie Jones, PE, MLE, RCDD, LEED AP Principal Quality Consulting Engineers, PLLC HUBZone Certified Small Business 6277-600 Carolina Commons Drive, #350 Indian Land SC 29707

SECTION TABLE OF CONTENTS

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

SECTION 00 31 00

AVAILABLE PROJECT INFORMATION

PART 1 GENERAL

1.1 Existing Conditions

-- End of Section Table of Contents --

DOCUMENT 00 31 00 Page 1

SECTION 00 31 00

AVAILABLE PROJECT INFORMATION

PART 1 GENERAL

1.1 Existing Conditions

Certain information relating to existing surface and subsurface conditions and structures is available to bidders for information and coordination.

A. Asbestos Management Plan dated December 5, 2014.

1. Building 81 Floor Layout Attachment Level 0 and Level 1 (Room Numbers).

2. Building 81 Floor Layout Attachment Level 2 and Level R (Room Numbers).

For convenience, a copy of each follows the end of this Section.

-- End of Section --

DOCUMENT 00 31 00 Page 2

12/5/2014Defense Distribution Center, Susquehanna ‐ 2014 Asbestos Management Plan

Appendix A ‐ Table A.1

Confirmed/Assumed ACM

Building: 00081

HM ID: M00081.004.A ‐ (004.A) 9" x 9" Floor Tile, Checkerboard Pattern, Green/Gray Material Category: Misc.

How Identified as ACM: Sampled

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 0, Room 1014, Corridor 1,027 S.F. Good Include in O&M Program R00081.0.1014

Level 0, Room 1088, Storage 437 S.F. Good Include in O&M Program R00081.0.1088

Level 0, Room 1004, Office 248 S.F. Good Include in O&M Program R00081.0.1004

Level 0, Room 1002, Office 1,024 S.F. Good Include in O&M Program R00081.0.1002

Level 0, Room 1001, Vault 103 S.F. Good Include in O&M Program R00081.0.1001

Level 0, Room 1003, Office 32 S.F. Good Include in O&M Program R00081.0.1003

Level 1, Room 1045, Office 273 S.F. Good Include in O&M Program R00081.1.1045

Level 1, Room 1085, Storage Room 104 S.F. Good Include in O&M Program R00081.1.1085

Level 1, Room 1039, Office 224 S.F. Good Include in O&M Program R00081.1.1039

Level 1, Room 1038, Conference Room 322 S.F. Good Include in O&M Program R00081.1.1038

Level 1, Room 1083, Telephone Communications 225 S.F. Good Include in O&M Program R00081.1.1083

Level 1, Room 1025, Office 4,714 S.F. Good Include in O&M Program R00081.1.1025

Level 1, Room 1082, File Room 312 S.F. Good Include in O&M Program R00081.1.1082

Level 1, Room 1040, Office 224 S.F. Good Include in O&M Program R00081.1.1040

Level 1, Room 1046, Office 8,387 S.F. Good Include in O&M Program R00081.1.1046

Level 1, Room 1044, Office 224 S.F. Good Include in O&M Program R00081.1.1044

Level 1, Room 1043, Office 392 S.F. Good Include in O&M Program R00081.1.1043

Level 1, Room 1042, Office 392 S.F. Good Include in O&M Program R00081.1.1042

Level 1, Room 1036, Janitor Room 28 S.F. Good Include in O&M Program R00081.1.1036

A-180

Confirmed/Assumed ACM

Building: 00081

HM ID: M00081.004.A ‐ (004.A) 9" x 9" Floor Tile, Checkerboard Pattern, Green/Gray Material Category: Misc.

How Identified as ACM: Sampled

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 1, Room 1081, Supply Room 55 S.F. Good Include in O&M Program R00081.1.1081

Level 1, Room 1023, Office 308 S.F. Good Include in O&M Program R00081.1.1023

Level 1, Room 1027, Office 240 S.F. Good Include in O&M Program R00081.1.1027

Level 1, Room 1033, Office 224 S.F. Good Include in O&M Program R00081.1.1033

Level 1, Room 1034, Corridor 264 S.F. Good Include in O&M Program R00081.1.1034

Level 1, Room 1024, Office 352 S.F. Good Include in O&M Program R00081.1.1024

Level 1, Room 1022, Office 249 S.F. Good Include in O&M Program R00081.1.1022

Level 1, Room 1020, Office 176 S.F. Good Include in O&M Program R00081.1.1020

Level 1, Room 1019, Break Room/Hall 250 S.F. Good Include in O&M Program R00081.1.1019

Level 1, Room 1018, Office 240 S.F. Good Include in O&M Program R00081.1.1018

Level 1, Room 1017, Office 150 S.F. Good Include in O&M Program R00081.1.1017

Level 1, Room 1016, Office 176 S.F. Good Include in O&M Program R00081.1.1016

Level 1, Room 1037, Office 140 S.F. Good Include in O&M Program R00081.1.1037

Level 1, Room 1026, Stairwell 64 S.F. Good Include in O&M Program R00081.1.1026

Level 2, Room 1055, Projection Room 150 S.F. Good Include in O&M Program R00081.2.1055

Level 2, Room 1048, Conference Room 220 S.F. Good Include in O&M Program R00081.2.1048

Level 2, Room 1049, Office 273 S.F. Good Include in O&M Program R00081.2.1049

Level 2, Room 1050, Office 208 S.F. Good Include in O&M Program R00081.2.1050

Level 2, Room 1051, Office 364 S.F. Good Include in O&M Program R00081.2.1051

A-181

Confirmed/Assumed ACM

Building: 00081

HM ID: M00081.004.A ‐ (004.A) 9" x 9" Floor Tile, Checkerboard Pattern, Green/Gray Material Category: Misc.

How Identified as ACM: Sampled

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 2, Room 1052, Office 364 S.F. Good Include in O&M Program R00081.2.1052

Level 2, Room 1084, Office 424 S.F. Good Include in O&M Program R00081.2.1084

Level 2, Room 1053, Office 208 S.F. Good Include in O&M Program R00081.2.1053

Level 2, Room 1086, Storage Closet 45 S.F. Good Include in O&M Program R00081.2.1086

Level 2, Room 1054, Office 8,095 S.F. Good Include in O&M Program R00081.2.1054

Level 2, Room 1066, Telecommunication Room 112 S.F. Good Include in O&M Program R00081.2.1066

Level 2, Room 1064, Office 4,731 S.F. Good Include in O&M Program R00081.2.1064

Level 2, Room 1063, Office 220 S.F. Good Include in O&M Program R00081.2.1063

Level 2, Room 1062, Conference Room 117 S.F. Good Include in O&M Program R00081.2.1062

Level 2, Room 1061, Office 220 S.F. Good Include in O&M Program R00081.2.1061

Level 2, Room 1060, Conference Room 130 S.F. Good Include in O&M Program R00081.2.1060

Level 2, Room 1058, Janitor Closet 4 S.F. Good Include in O&M Program R00081.2.1058

Level 2, Room 1056, Conference Room 724 S.F. Good Include in O&M Program R00081.2.1056

Level 2, Room 1087, VIP Room 186 S.F. Good Include in O&M Program R00081.2.1087

HM ID: M00081.004.B ‐ (004.B) Floor Tile Mastic, Black Material Category: Misc.

How Identified as ACM: Sampled

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 0, Room 1001, Vault 103 S.F. Good Include in O&M Program R00081.0.1001

Level 0, Room 1002, Office 1,024 S.F. Good Include in O&M Program R00081.0.1002

A-182

Confirmed/Assumed ACM

Building: 00081

HM ID: M00081.004.B ‐ (004.B) Floor Tile Mastic, Black Material Category: Misc.

How Identified as ACM: Sampled

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 0, Room 1003, Office 32 S.F. Good Include in O&M Program R00081.0.1003

Level 0, Room 1004, Office 248 S.F. Good Include in O&M Program R00081.0.1004

Level 0, Room 1014, Corridor 1,027 S.F. Good Include in O&M Program R00081.0.1014

Level 0, Room 1088, Storage 437 S.F. Good Include in O&M Program R00081.0.1088

Level 1, Room 1022, Office 249 S.F. Good Include in O&M Program R00081.1.1022

Level 1, Room 1037, Office 140 S.F. Good Include in O&M Program R00081.1.1037

Level 1, Room 1019, Break Room/Hall 250 S.F. Good Include in O&M Program R00081.1.1019

Level 1, Room 1045, Office 273 S.F. Good Include in O&M Program R00081.1.1045

Level 1, Room 1046, Office 8,387 S.F. Good Include in O&M Program R00081.1.1046

Level 1, Room 1081, Supply Room 55 S.F. Good Include in O&M Program R00081.1.1081

Level 1, Room 1082, File Room 312 S.F. Good Include in O&M Program R00081.1.1082

Level 1, Room 1083, Telephone Communications 225 S.F. Good Include in O&M Program R00081.1.1083

Level 1, Room 1085, Storage Room 104 S.F. Good Include in O&M Program R00081.1.1085

Level 1, Room 1043, Office 392 S.F. Good Include in O&M Program R00081.1.1043

Level 1, Room 1042, Office 392 S.F. Good Include in O&M Program R00081.1.1042

Level 1, Room 1040, Office 224 S.F. Good Include in O&M Program R00081.1.1040

Level 1, Room 1038, Conference Room 322 S.F. Good Include in O&M Program R00081.1.1038

Level 1, Room 1044, Office 224 S.F. Good Include in O&M Program R00081.1.1044

Level 1, Room 1025, Office 4,714 S.F. Good Include in O&M Program R00081.1.1025

A-183

Confirmed/Assumed ACM

Building: 00081

HM ID: M00081.004.B ‐ (004.B) Floor Tile Mastic, Black Material Category: Misc.

How Identified as ACM: Sampled

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 1, Room 1017, Office 150 S.F. Good Include in O&M Program R00081.1.1017

Level 1, Room 1018, Office 240 S.F. Good Include in O&M Program R00081.1.1018

Level 1, Room 1020, Office 176 S.F. Good Include in O&M Program R00081.1.1020

Level 1, Room 1016, Office 176 S.F. Good Include in O&M Program R00081.1.1016

Level 1, Room 1039, Office 224 S.F. Good Include in O&M Program R00081.1.1039

Level 1, Room 1024, Office 352 S.F. Good Include in O&M Program R00081.1.1024

Level 1, Room 1036, Janitor Room 28 S.F. Good Include in O&M Program R00081.1.1036

Level 1, Room 1026, Stairwell 64 S.F. Good Include in O&M Program R00081.1.1026

Level 1, Room 1027, Office 240 S.F. Good Include in O&M Program R00081.1.1027

Level 1, Room 1033, Office 224 S.F. Good Include in O&M Program R00081.1.1033

Level 1, Room 1034, Corridor 264 S.F. Good Include in O&M Program R00081.1.1034

Level 1, Room 1023, Office 308 S.F. Good Include in O&M Program R00081.1.1023

Level 2, Room 1053, Office 208 S.F. Good Include in O&M Program R00081.2.1053

Level 2, Room 1056, Conference Room 724 S.F. Good Include in O&M Program R00081.2.1056

Level 2, Room 1055, Projection Room 150 S.F. Good Include in O&M Program R00081.2.1055

Level 2, Room 1058, Janitor Closet 4 S.F. Good Include in O&M Program R00081.2.1058

Level 2, Room 1060, Conference Room 130 S.F. Good Include in O&M Program R00081.2.1060

Level 2, Room 1061, Office 220 S.F. Good Include in O&M Program R00081.2.1061

Level 2, Room 1062, Conference Room 117 S.F. Good Include in O&M Program R00081.2.1062

A-184

Confirmed/Assumed ACM

Building: 00081

HM ID: M00081.004.B ‐ (004.B) Floor Tile Mastic, Black Material Category: Misc.

How Identified as ACM: Sampled

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 2, Room 1063, Office 220 S.F. Good Include in O&M Program R00081.2.1063

Level 2, Room 1064, Office 4,731 S.F. Good Include in O&M Program R00081.2.1064

Level 2, Room 1066, Telecommunication Room 112 S.F. Good Include in O&M Program R00081.2.1066

Level 2, Room 1051, Office 364 S.F. Good Include in O&M Program R00081.2.1051

Level 2, Room 1086, Storage Closet 45 S.F. Good Include in O&M Program R00081.2.1086

Level 2, Room 1052, Office 364 S.F. Good Include in O&M Program R00081.2.1052

Level 2, Room 1087, VIP Room 186 S.F. Good Include in O&M Program R00081.2.1087

Level 2, Room 1084, Office 424 S.F. Good Include in O&M Program R00081.2.1084

Level 2, Room 1054, Office 8,095 S.F. Good Include in O&M Program R00081.2.1054

Level 2, Room 1049, Office 273 S.F. Good Include in O&M Program R00081.2.1049

Level 2, Room 1048, Conference Room 220 S.F. Good Include in O&M Program R00081.2.1048

Level 2, Room 1050, Office 208 S.F. Good Include in O&M Program R00081.2.1050

HM ID: M00081.008.A ‐ (008.A) 9" x 9" Floor Tile, Checkerboard Pattern, Beige/Lt. Brown Material Category: Misc.

How Identified as ACM: Sampled

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 0, Room 1008, Conference Room 600 S.F. Good Include in O&M Program R00081.0.1008

Level 0, Room 1007, Dining Room 840 S.F. Good Include in O&M Program R00081.0.1007

A-185

Confirmed/Assumed ACM

Building: 00081

HM ID: M00081.013.A ‐ (013.A) Resilient Sheet Flooring, Tan, Under Existing Finishes Material Category: Misc.

How Identified as ACM: Sampled

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 1, Room 1029, Lobby 905 S.F. Good Include in O&M Program R00081.1.1029

Level 1, Room 1031, Exit Door 40 S.F. Good Include in O&M Program R00081.1.1031

HM ID: M00081.019.A ‐ (019.A) 12" x 12" Floor Tile, Gray, Black Streaks Material Category: Misc.

How Identified as ACM: Assumed ACM

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 2, Room 1065, Kitchen 48 S.F. Good R00081.2.1065

Level 2, Room 1068, Coffee Room 54 S.F. Good R00081.2.1068

Level 2, Room 1069, Restroom 40 S.F. Good R00081.2.1069

HM ID: M00081.019.B ‐ (019.B) Floor Tile Mastic, Black Material Category: Misc.

How Identified as ACM: Assumed ACM

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 2, Room 1068, Coffee Room 54 S.F. Good R00081.2.1068

Level 2, Room 1065, Kitchen 48 S.F. Good R00081.2.1065

Level 2, Room 1069, Restroom 40 S.F. Good R00081.2.1069

HM ID: M00081.021.A ‐ (021.A) Fire Doors, Hinged (Passage Door), Suspect Core Material Category: Misc.

How Identified as ACM: Assumed ACM

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 0, Room 1076, Stairwell 1 Each Good Include in O&M Program R00081.0.1076

A-186

Confirmed/Assumed ACM

Building: 00081

HM ID: M00081.021.A ‐ (021.A) Fire Doors, Hinged (Passage Door), Suspect Core Material Category: Misc.

How Identified as ACM: Assumed ACM

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 1, Room 1077, Stairwell 1 Each Good Include in O&M Program R00081.1.1077

Level 2, Room 1078, Stairwell 1 Each Good Include in O&M Program R00081.2.1078

HM ID: M00081.024.A ‐ (024.A) Roofing System Materials, Under Existing Finishes Material Category: Misc.

How Identified as ACM: Assumed ACM

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level R, Room X000, Roof 24,798 S.F. Good Include in O&M Program R00081.R.X000

HM ID: M00081.025.A ‐ (025.A) Pipe Insulation, Gray Material Category: TSI

How Identified as ACM: Assumed ACM

Material Location Material Quanity Material Condition Recommended Response Action Room, ID

Level 0, Room 1088, Storage 5 L.F. Good Include in O&M Program R00081.0.1088

A-187

00 43 22 - 1

SECTION 00 43 22

UNIT PRICES FORM

FROM:

Contractor License No. ____________________(hereinafter called "Bidder")

TO: US Army Corps of Engineers, Charleston District(hereinafter called "Owner") Project Technical Point of Contact: Nancy Jenkins 69A Hagood Avenue Charleston, SC 294

RE: Architect Engineer Project No. 2015-239

1.1 UNIT PRICES

The Undersigned agrees that the following UNIT PRICES shall govern changes in the Work, whether they be ADDITIONS or DEDUCTIONS to the Contract Sum required during the course of the Work. Unit Prices shall be the same for Additions or Deductions. All Unit Prices shall be total installed costs including overhead, profit, geotechnical engineering and all other necessary costs. Proposing separate add and deduct unit prices shall subject this Bid Proposal to being rejected as "non-responsive."

ITEM & UNIT OF MEASURE ADDITION or DEDUCTION (Enter one price only)

A. ASBESTOS REMOVAL AND ABATEMENT:

1. Asbestos Removal-Floor Tile: Price per square foot in place. $

a. Area of Removal and Abatement (insert square footage). Square foot in place. __________

(sq.ft.)

B. ASBESTOS REMOVAL AND ABATEMENT:

1. Asbestos Removal-Ceiling Tile: Price per square foot in place. $

a. Area of Removal and Abatement (insert square footage). Square foot in place. __________

(sq.ft.)

C. ASBESTOS REMOVAL AND ABATEMENT:

1. Asbestos Removal-Pipe Insulation: Price per square foot in place. $

a. Area of Removal and Abatement (insert square footage). Square foot in place. __________

(sq.ft.)

00 43 22 - 2

Respectfully submitted:

Bidder:

By: Date:

Title:

Business Address:

SEAL

Telephone Number: ( ) If Bid is by a Corporation

END OF SECTION

LEED 2009 for New Construction and Major Renovations DLA Bldg 81

Project Checklist

6 2 18 Possible Points: 26 Y ? N Y ? N

Y Prereq 1 2 Credit 4 1 to 2 1 Credit 1 1 2 Credit 5 1 to 2

5 Credit 2 5 1 Credit 6 Rapidly Renewable Materials 1 1 Credit 3 Brownfield Redevelopment 1 1 Credit 7 1 6 Credit 4.1 6 1 Credit 4.2 1 10 1 4 Possible Points: 15

3 Credit 4.3 Alternative Transportation—Low-Emitting and Fuel-Efficient Vehicles 3 2 Credit 4.4 2 Y Prereq 1

1 Credit 5.1 Site Development—Protect or Restore Habitat 1 Y Prereq 2

1 Credit 5.2 Site Development—Maximize Open Space 1 1 Credit 1 1 1 Credit 6.1 Stormwater Design—Quantity Control 1 1 Credit 2 1 1 Credit 6.2 Stormwater Design—Quality Control 1 1 Credit 3.1 1

1 Credit 7.1 Heat Island Effect—Non-roof 1 1 Credit 3.2 1 1 Credit 7.2 1 1 Credit 4.1 1

1 Credit 8 Light Pollution Reduction 1 1 Credit 4.2 1 1 Credit 4.3 1

2 6 2 Possible Points: 10 1 Credit 4.4 1 1 Credit 5 1

Y Prereq 1 1 Credit 6.1 Controllability of Systems—Lighting 1 4 Credit 1 Water Efficient Landscaping 2 to 4 1 Credit 6.2 1

2 Credit 2 Innovative Wastewater Technologies 2 1 Credit 7.1 1 2 2 Credit 3 2 to 4 1 Credit 7.2 Thermal Comfort—Verification 1

1 Credit 8.1 1 10 9 16 Possible Points: 35 1 Credit 8.2 1

Y Prereq 1 3 3 Possible Points: 6 Y Prereq 2

Y Prereq 3 1 Credit 1.1 1 5 5 9 Credit 1 1 to 19 1 Credit 1.2 1

7 Credit 2 1 to 7 1 Credit 1.3 1 2 Credit 3 2 1 Credit 1.4 1

2 Credit 4 2 1 Credit 1.5 1 3 Credit 5 3 1 Credit 2 1

2 Credit 6 2 1 2 1 Possible Points: 4

7 5 2 Possible Points: 14 1 Credit 1.1 1

Y Prereq 1 1 Credit 1.2 1 1 2 Credit 1.1 1 to 3 1 Credit 1.3 1

1 Credit 1.2 Building Reuse—Maintain 50% of Interior Non-Structural Elements 1 1 Credit 1.4 1 1 1 Credit 2 1 to 2

1 1 Credit 3 1 to 2 39 28 43 Possible Points: 110

Regional Priority: EQc7.1 Thermal Comfort Regional Priority: WEc3 Water Use Reduction 40% Regional Priority: Specific Credit

Storage and Collection of Recyclables

Materials and Resources

Fundamental Commissioning of Building Energy Systems

Measurement and Verification

Construction Waste Management

Enhanced Commissioning On-Site Renewable Energy

Enhanced Refrigerant Management

Green Power

Optimize Energy Performance

Minimum Energy Performance Fundamental Refrigerant Management

Materials and Resources, Continued

Water Efficiency

Building Reuse—Maintain Existing Walls, Floors, and Roof

Alternative Transportation—Parking Capacity

Heat Island Effect—Roof

Recycled Content Regional Materials

Certified Wood

Alternative Transportation—Bicycle Storage and Changing Rooms

Sustainable Sites

Alternative Transportation—Public Transportation Access

Site Selection Development Density and Community Connectivity

Construction Activity Pollution Prevention

LEED Accredited Professional

Certified 40 to 49 points Silver 50 to 59 points Gold 60 to 79 points Platinum 80 to 110

Construction IAQ Management Plan—During Construction

Outdoor Air Delivery Monitoring

Total

Energy and Atmosphere

Water Use Reduction—20% Reduction

Low-Emitting Materials—Composite Wood and Agrifiber Products Low-Emitting Materials—Flooring Systems

Indoor Chemical and Pollutant Source Control

Thermal Comfort—Design Controllability of Systems—Thermal Comfort

Water Use Reduction

Daylight and Views—Views Daylight and Views—Daylight

Materials Reuse

Indoor Environmental Quality

Minimum Indoor Air Quality Performance Environmental Tobacco Smoke (ETS) Control

Increased Ventilation

Regional Priority Credits

Innovation and Design Process

Low-Emitting Materials—Adhesives and Sealants Low-Emitting Materials—Paints and Coatings

Construction IAQ Management Plan—Before Occupancy

Innovation in Design: Green Cleaning Innovation in Design: 30% regional exemplary

Innovation in Design: Educational Program Innovation in Design: Low Mercury Florescent Lights

Innovation in Design: Specific Title

Regional Priority: EAc1 Optimize Energy 28%

Building 84 Renovation Project Defense Distribution Center, Susquehanna New Cumberland, PA

SECTION 01 11 00 – Summary of Work Page 1 of 11

SECTION 01 11 00

SUMMARY OF WORK

08/11

Table of Contents

PART 1 GENERAL

1.1 REFERENCES

1.2 DEFINITIONS

1.3 SUBMITTALS

1.4 WORK COVERED BY CONTRACT DOCUMENTS

1.4.1 Project Description

1.4.2 Location

1.5 WORK RESCHEDULING

1.6 OCCUPANCY OF PREMISES

1.7 EXISTING WORK

1.8 ON-SITE PERMITS

1.8.1 Utility Outage Requests and Utility Connection Requests

1.8.2 Digging, Welding, and Burning Permits

1.9 LOCATION OF UNDERGROUND UTILITIES

1.9.1 Notification Prior to Excavation

1.10 FIRE WATCH

1.11 CONSTRUCTION CONSTRAINTS

1.11.1 Operations Requirements:

1.11.2 Contractor’s Working Hours:

1.11.3 Contractor Request:

1.11.4 Window Demo/Replacement:

1.11.5 Heating System Demo/Install:

1.11.6 Transporter Enclosures Renovations

1.11.7 Battery Room Ventilation System Demo/Install

1.11.8 Electric Demo/Install:

1.11.9 Fire Protection and Fire Alarm Systems Demo/Installation:

1.12 GOVERNMENT-FURNISHED MATERIAL AND EQUIPMENT

1.13 SALVAGE MATERIAL AND EQUIPMENT

PART 2 PRODUCTS

PART 3 EXECUTION

SECTION 01 11 00 – Summary of Work Page 2 of 11

SECTION 01 11 00

SUMMARY OF WORK

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM E2114 (2008) Standard Terminology for Sustainability Relative to the

Performance of Buildings

GREEN BUILDING INITIATIVE (GBI)

Green Globes (2004) Green Globes(™) US Green Building Rating System

U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA)

Energy Star (1992; R 2006) Energy Star Energy Efficiency Labeling System

U.S. GREEN BUILDING COUNCIL (USGBC)

LEED NC (2009) Leadership in Energy and Environmental Design(tm) New

Construction Rating System

1.2 DEFINITIONS

Definitions pertaining to sustainable development are as defined in ASTM E2114, Section 01 57 19.00 20, TEMPORARY ENVIRONMENTAL CONTROLS, and as specified.

a. "Environmentally preferable products" have a lesser or reduced effect on the environment in comparison to conventional products and services. This comparison may consider raw materials acquisition, production, manufacturing, packaging, distribution, reuse, operation, maintenance, or disposal of the product.

b. "Indoor environmental quality" is the physical characteristics of the building interior that impact occupants, including air quality, illumination, acoustics, occupant control, thermal comfort, daylighting, and views.

c. "Operational performance" is the functional behavior of the building as a whole or of the building components.

d. "Sustainability" is the balance of environmental, economic, and societal considerations.

1.3 SUBMITTALS

Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. The following shall be submitted in accordance with Section 01 33 00, SUBMITTAL PROCEDURES:

SECTION 01 11 00 – Summary of Work Page 3 of 11

SD-01 Preconstruction Submittals Construction Sequence; G

1.4 WORK COVERED BY CONTRACT DOCUMENTS

1.4.1 Project Description

Renovation of Building 84, which includes but is not limited to the following.

Repair exterior of the building by repainting the exterior CMU walls, downspouts, doors and frames, and associated exterior accessories providing a uniform and aesthetic appearance.

Replace existing warehouse windows with translucent panels and louvers, or CMU infill.

Install a new high speed roll-up doors on east and west end of the building. Repair existing steam heat system and piping within the warehouse and Administration Annex areas by replacement. These repairs include replacement of the following:

a. Unit Heaters

b. Piping

c. Ventilation Units and Ductwork

d. Building Automation System, etc.

e. Steam system conversion to hot water to all of Building 84

The Warehouse and Administration Areas shall remain fully operational during construction.

New exhaust fans will replace existing units at the same locations. New air rotation units will be installed in all bays.

Update the electrical system so that the entire building is served by a single, new, centrally located electrical service and associated electrical gear. The new service entrance gear shall re-feed all existing service entrance gear, metering, transformers, distribution panel boards, etc. as required to maintain complete and usable system. The new service entrance gear shall also be used to feed new electrical distribution gear associated with the additional building upgrades. Remove/replace obsolete electrical gear currently installed within the building.

Repair existing fire protection piping and heads by replacement. These repairs include removal of existing fire protection piping and heads, and installation of new ESFR sprinkler system. Construct new exterior sprinkler control riser enclosures. Remove existing fire alarm panels and install new fire alarm panels.

Repair battery room exhaust fans by replacement. Provide new hydrogen monitoring system to provide alarm signal in the event of high hydrogen content.

1.4.2 Location

The work shall be located at Defense Distribution Center, Susquehanna in New Cumberland, PA. Refer to the Contract Drawings for specific location(s) on site for the work and construction lay-down areas.

SECTION 01 11 00 – Summary of Work Page 4 of 11

1.5 WORK RESCHEDULING

Normal duty hours for work shall be from 0700 to 1530, Monday through Friday excluding all federal holidays. Requests for work off hours shall require written approval from the Contracting Officer Representative (COR) no less than 15 working days in advance of the proposed work period.

1.6 OCCUPANCY OF PREMISES

The Work in Building 81 cannot begin until DLA Distribution staff relocates to the new HQ Facility (430).

Before work is started, the Contractor shall prepare and submit a Construction Sequence to the COR detailing the sequence of procedures, means of access, space for storage of materials and equipment, and use of approaches, corridors, and stairways required to successfully execute the work. This sequence shall be provided in writing and shall be approved by the COR prior to the start of any work. See Section 01 32 01.00 10, PROJECT SCHEDULE for further details.

1.7 EXISTING WORK

In addition to "FAR 52.236-9, Protection of Existing Vegetation, Structures, Equipment, Utilities, and Improvements":

a. Remove or alter existing work in such a manner as to prevent injury or damage to any portions of the existing work which remain.

b. Repair or replace portions of existing work which have been damaged or altered during construction operations to match existing or adjoining work, as approved by the Contracting Officer. At the completion of operations, existing work shall be in a condition equal to or better than that which existed before new work started.

1.8 ON-SITE PERMITS

1.8.1 Utility Outage Requests and Utility Connection Requests

Work shall be scheduled to hold outages to a minimum.

Requests for utility outages and connections shall be made in writing to the COR at least 15 working days in advance of the time required. Each request shall state the system involved, area involved, approximate duration of outage, and the nature of work involved.

1.8.2 Digging, Welding, and Burning Permits

ACTIVITY SUBMISSION DATE SUBMISSION FORM

Digging / Excavation 10 working days prior to work Dig Permit COR will supply when requested.

Confined Space Entry Daily (12 hours maximum) Confined Space Entry Permit

SECTION 01 11 00 – Summary of Work Page 5 of 11

Hot Work Daily Hot Work Permit

Issued by Fire Department when requested.

Utility Outage 15 working days N/A

Permits shall be posted at a conspicuous location in the construction area. Burning of trash or rubbish is not permitted on project site.

1.9 LOCATION OF UNDERGROUND UTILITIES

Contractor is responsible for requesting existing underground utilities be located prior to beginning work. Contractor is also responsible for verifying the elevations of existing piping, utilities, and any type of underground or encased obstruction not indicated to be relocated or removed but indicated or discovered during scanning in locations to be traversed by piping, ducts, and other work to be conducted or installed. Verify elevations before installing new work closer than nearest manhole or other structure at which an adjustment in grade can be made. See Section 01 78 00, CLOSEOUT SUBMITTALS for additional information.

1.9.1 Notification Prior to Excavation

Contact PA One Call to have publicly (Utility Company) owned underground utilities located and also submit a Dig Permit through the COR to have privately (Government) owned underground utilities located. Contractor is responsible for maintaining markings provided by both PA One Call and Dig Permit once utilities are marked and throughout construction.

Notify the COR to request a Dig Permit at least 10 working days prior to starting excavation work. Damage to existing marked utilities shall be repaired at the contractor’s expense.

1.10 FIRE WATCH

Provide a qualified person to perform Fire Watch duties when required by NFPA or the Contract Documents. This person shall maintain an active identification badge allowing unescorted access to all areas of Building 84 at all times. Hours and frequency of patrols shall be coordinated with the COR at the beginning of construction.

1.11 CONSTRUCTION CONSTRAINTS

Building 85 must remain fully operational during construction. The following construction phasing requirements and work restrictions were provided by DLA. Contractor shall include a Phasing Schedule for approval by COR prior to start of work. Refer to Section 01 32 01.00 10

PROJECT SCHEDULE.

1.11.1 Operations Requirements:

The Contractor shall adhere to the following operational requirements and constraints:

1.11.1.1 Operations will remain fully functional for the project duration.

a. Construction shall not adversely affect Operations.

SECTION 01 11 00 – Summary of Work Page 6 of 11

b. Access to contractor blocked storage areas shall be provided within two (2) hours of a request being submitted by the government.

c. No more than three (3) bays for major work activities may be worked on simultaneously during the project (two (2) bays for concurrent mechanical and electrical work, and one

(1) other bay for fire protection work). Small incidental work may be requested in other bays than those three (3) bays thru the COR but must be approved by the government.

Permission to expand work activities to additional bays MAY be granted but should not be expected as a foregone conclusion.

d. Storage materiel must be moved by Operations. When stored materiel must be moved for construction, the Contractor must schedule a move request thru the COR, see Contractor Request paragraph below.

e. Operation’s has two (2) packaging areas in the building. One shall always remain fully operational during the project.

f. Interior aisles must remain readily accessible to MHE traffic during construction.

g. Exterior docks must remain readily accessible to MHE traffic during construction.

h. Protect existing equipment, stored materiel, and existing facility during construction.

i. During renovation efforts on the transporter stations, only one transporter enclosure will be taken out of service at a time. In addition, the transporter located on the west side of the building is to be renovated first.

j. During construction of the new mechanical room, a temporary alternate method of egress from the dock in the vicinity of the mechanical room is to be provided.

1.11.2 Contractor’s Working Hours:

Comply with the following working hour requirements:

a. Normal Working Hours: 0700 thru 1500.

b. Potential lead and asbestos abatement activities and handling of hazardous materials must be performed on second and third shifts (1530 thru 0530 hours).

c. Scheduled power outages/service switch over shall occur on Sundays only.

1.11.3 Contractor Request:

Procedure for Contractor requests necessary for construction activities shall be as follows:

a. Barricading floor areas and doors must be scheduled and pre-approved by the government through the COR. All requests shall be submitted 24 hours in advance to setting up a barricade/caution tape.

b. Small incidental (daily) stored materiel moves (for construction access) must be requested 24 hours in advance of construction activities through the COR.

SECTION 01 11 00 – Summary of Work Page 7 of 11

c. Removal of stored materiel for installation of fire suppression systems:

(1) Materiel stored on the top shelf of existing racking will be moved one (1) bay at a time by the government prior to starting the fire protection work (remaining storage on lower shelves will not be moved). The Government is only capable of moving one bay (top rack only) of storage at a time based on available alternative storage space.

(2) The Contractor shall submit materiel move requests to the COR. For moves that require less than a full bay of materiel to be moved (a maximum of two (2) rows equivalent), 14 days advanced notice shall be provided to the COR. For materiel moves that exceed this quantity up to a full bay, a minimum of 30 calendar days shall be provided to the COR to affect the relocation of this much materiel.

1.11.4 Window Demo/Replacement:

Proceed as follows:

a. Removal of existing windows and installation of new window/louvers on north side of building shall occur one (1) bay at a time until all five (5) bays are completed. This work will not be scheduled or completed during the winter months (November through April).

1.11.5 Heating System Demo/Install:

a. Temporary heating shall be provided if heating system is not fully operational and commissioned by October 15, 2016. Contractor shall maintain the temperature inside the building's exterior walls between 55 to 60 degrees F from October 15th, 2016 continuously through May 15th, 2017. Energy required for heating the building will be provided by the Contractor.

b. Not more than two (2) bays may be worked on simultaneously.

c. Construction of the new mechanical room located on the northwest dock area shall not impede traffic or trucks being utilized for materiel transfers. Most materiel transfers will be accomplished at transporter areas, however, there will be trucks being unloaded at other north dock locations at times. Coordinate construction vehicle access and construction material laydown area (for mechanical room only) with the COR. Any damage to pavement (asphalt or concrete) or damage to grass areas not in the contractor’s area of work shall be repaired at the Contractor’s expense.

1.11.6 Transporter Enclosures Renovations

The Contractor shall perform prescribed transporter renovations as follows:

a. Transporters are conveyor systems used for the transport of materiel from the warehouse to active combat units around the world. As such, a minimum of two of these enclosures must remain operational at all times.

b. These conveyor systems are enclosed to protect materiel from inclement weather. These enclosures are in need of repair by replacement of various components of the enclosure.

SECTION 01 11 00 – Summary of Work Page 8 of 11

In some cases it will be necessary to support conveyor systems while renovations to enclosures are being made as the conveyors are supported by the enclosure itself. Confirm the slope of conveyors and their configuration prior to the start of work on an enclosure to assure that the conveyor system is returned to operations in the same condition as when renovations began.

c. Provide signs and barriers at transporter conveyor loading point within the warehouse to assure that conveyors are not loaded or used during renovation.

1.11.7 Battery Room Ventilation System Demo/Install

a. A minimum of one (1) exhaust fan shall remain operational in the battery charging room at all times. There are a total of three (3) fans being replaced in this area.

1.11.8 Electric Demo/Install:

a. Not more than two (2) bays may be worked on simultaneously.

b. Building shall maintain full power for the duration of the project with the exception of scheduled power outages. Schedule and coordinate power outages through the COR.

c. Power outages/service switchovers shall be scheduled for Sundays only.

d. Scheduled outages shall last no longer than six (6) hours per scheduled event.

e. Outdoor/Medium voltage work (demolition or proposed new work) that will require de-energization of the 12.47 KV electrical circuit feeding the building will need to be coordinated/scheduled through the COR. Request must be submitted a minimum of three

(3) weeks in advance of the proposed outage.

f. Utility Crossing “U” Avenue - one lane of traffic shall be kept open at all times for thru traffic along “U” Avenue. Both lanes shall be available when the Contractor is not working or on site. Contractor shall provide traffic control while engaged in construction activities associated with running power crossing the road.

g. Government shall receive a (48) hour notice prior to traffic pattern changes being implemented.

1.11.9 Fire Protection and Fire Alarm Systems Demo/Installation:

a. Contractor shall be permitted to work in only one (1) bay at a time.

b. If any portion of the sprinkler system is not fully functional (impaired), a 24 hour a day fire watch will be required for that portion of the facility by the Contractor until the system is returned to a fully functional status.

c. An entire bay shall be completed and fully functional before work in another bay may begin.

1.12 GOVERNMENT-FURNISHED MATERIAL AND EQUIPMENT

SECTION 01 11 00 – Summary of Work Page 9 of 11

Unless otherwise notified by the Contracting Officer, the Contractor, with his own forces, shall transport all Government furnished equipment / materials described in the Contract Documents. The equipment/materials will be transported from the Government storage area to the work site indicated in the Contract Documents.

Government will provide the following equipment for Contractor-Installation:

a. New pole-mounted transformer for street lighting.

1.13 SALVAGE MATERIAL AND EQUIPMENT

Materials and equipment to be salvaged as identified by the contract documents shall remain the property of the Government. The salvaged property shall be segregated, itemized, delivered, and off-loaded at the Government designated storage area located on the Defense Distribution Center Susquehanna site.

Contractor shall maintain property control records for material or equipment designated as salvage. Contractor's system of property control may be used if approved by the Contracting Officer. Contractor shall be responsible for storage and protection of salvaged materials and equipment until receipt and acceptance of salvage material by the COR. Salvaged material under the Contractor’s control that is damaged prior to turnover to the Government shall be replaced by the Contractor at Contractor’s expense. Salvage material shall be documented on Form DD 250 and DD250C (continuation if necessary). A copy of this form is attached and shall be made electronically available by the COR. Instructions for the proper preparation of this form can be found at the following link, Part 4:

http://farsite.hill.af.mil/reghtml/regs/far2afmcfars/fardfars/dfars/DFARSApxF.htm

PART 2 PRODUCTS

Not Used

PART 3 EXECUTION

Not used http://farsite.hill.af.mil/reghtml/regs/far2afmcfars/fardfars/dfars/DFARSApxF.htm�

SECTION 01 11 00 – Summary of Work Page 10 of 11

SECTION 01 11 00 – Summary of Work Page 11 of 11

01 14 00 – Work Restrictions Page 1 of 11

SECTION 01 14 00

WORK RESTRICTIONS

11/11

Table of Contents

GENERAL ............................................................................................................................ 2 PART 1

1.1 REFERENCES

1.2 SUBMITTALS

1.3 SPECIAL SCHEDULING REQUIREMENTS

1.3.1 Materials, Equipment, and Personnel

1.3.2 Active Facility

1.3.3 Construction Interruptions

1.3.4 Scheduling Interruptions

1.3.5 Wartime Interruption

1.4 CONTRACTOR ACCESS AND USE OF PREMISES

1.4.1 Activity Regulations

1.4.2 Working Hours

1.4.3 Work Outside Regular Hours

1.4.4 Occupied and Existing Buildings

1.4.5 Utility Cutovers and Interruptions

1.4.6 Refinished Roadwork

PRODUCTS .......................................................................................................................... 8 PART 2

EXECUTION ........................................................................................................................ 8 PART 3

01 14 00 – Work Restrictions Page 2 of 11

SECTION 01 14 00

WORK RESTRICTIONS

GENERAL PART 1

1.1 REFERENCES

The publications listed below form a part of this section to the extent referenced. The publications are referred to within the text by the basic designation only.

Defense Logistics Agency

DLA Physical Security Manual

Defense Distribution Center Susquehanna – Installation Access Policy

Defense Distribution Center Susquehanna – Image Capturing Device Policy

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation; submittals not having a

"G" designation are for information only. The following shall be submitted in accordance with

Section 01 33 00, SUBMITTAL PROCEDURES:

SD-01 Preconstruction Submittals

List of Contact Personnel; G

Completed Contractor and Visitor Badge Request Form – (Short Form); G

DDSP Security Information – (Long Form); G

Camera Pass Request Form; G

1.3 SPECIAL SCHEDULING REQUIREMENTS

1.3.1 Materials, Equipment, and Personnel

Have materials, equipment, and personnel required to perform the work at the site prior to the commencement of the work.

1.3.2 Active Facility

The activity at the facility under construction will remain in operation during the entire construction period. The Contractor must conduct his operations so as to cause the least possible interference with normal operations of the activity.

1.3.3 Construction Interruptions

Permission to interrupt any active roads, railroads, and/or parking areas must be requested in writing a minimum of 15 working days prior to the desired date of interruption. In addition, work that will impact existing employee workspaces or material storage areas, etc. shall require a file:///C:/Users/ysp5927/Specifications/Masters/UFGS/prntdata/01%2033%2000.doc

01 14 00 – Work Restrictions Page 3 of 11 minimum additional advance notification not less than (15) working days in advance of the proposed activities. Coordinate all activities through the Contracting Officer Representative

(COR).

1.3.4 Scheduling Interruptions

The work under this Contract requires special attention to the scheduling of activities within the building. This facility functions primarily as a storage facility for thousands of parts. Access to these parts by Government employees during construction is critical as many of these items are required for our armed forces to function properly. The Contractor shall identify on the

Construction Schedule each factor which constitutes a potential interruption to operations. The

COR and Contractor shall work with operations personnel to coordinate these interruptions so as to affect minimal impact to the mission.

1.3.5 Wartime Interruption

In the event that the United States becomes engaged in a war, operations may require unobstructed access to the warehouse for an extended period of time. If this occurs, it will be necessary to suspend the project until such time as operations is no longer requires this level of access.

1.4 CONTRACTOR ACCESS AND USE OF PREMISES

1.4.1 Activity Regulations

Ensure that Contractor personnel employed on this project become familiar with and obey

Installation regulations including Safety, Fire, Traffic, and Security Regulations. Keep within the limits of the work and avenues of ingress and egress. To minimize traffic congestion, delivery of materials should be outside of peak traffic hours which are 0630 to 0800 and after

1530 unless otherwise approved by the Contracting Officer (KO). Wear Hard Hats, Safety

Shoes, Reflective Vests, and Eye Protection at all times in designated areas.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .