SOW HYDRAULIC TEST PUMP STAND.docx
DOCX document 88 KB Posted
- Attached to
- Hydraulic Pump Test Stand RFQ Federal contract opportunity
- Solicitation number
- N6852023R0016
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Hydraulic Pump Test Stand QA.docx | DOCX document | |
| Hydraulic Pump Test Stand QA.docx | DOCX document | |
| RFQ Full Text Clauses and Provisions.docx | DOCX document | |
| Hydraulic Pump Test Stand QA.docx | DOCX document | |
| SOW HYDRAULIC TEST PUMP STAND.docx | DOCX document | |
| Combined Synopsis Solicitation.docx | DOCX document | |
| RFQ Full Text Clauses and Provisions.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FLEET READINESS CENTER MID-ATLANTIC Voyage Repair Team, Mayport Florida Building 1613 Naval Station Mayport, Mayport Florida 32228
STATEMENT OF WORK FOR CONTRACTURAL PROCUREMENT OF JET BLAST DEFLECTOR HYDRAULIC TEST PUMP AND STAND (FY-23)
Ref: (a) NAVAIR 51-70-13 JBD Manual
1. The FRCMA Voyage Repair Team (VRT), a source approved Department of the Navy ALRE ship repair facility has been tasked to receive, inspect repair and test 78 each Jet Blast Deflector (JBD) cylinders by NAVSUP. After repair of the each JBD assembly is complete each one must be hydraulically tested per ref: (a). Our current pump has reached its feasible repair threshold and must be replaced.
2. The following specifications are required on the new test pump:
· Pump Type - Piston Pump
· Max pressure 10,000 PSI
· Operating range 1000-6000 PSI
· Gage Panel, pressure gages are liquid filled ( request spare set) calibrated from an accredited calibration lab with cert paperwork
· Pressure controlled by a remote relief valve with a hand dial manual adjustment
· Pressure gages are liquid filled ( request spare set) calibrated from an accredited calibration lab with certification paperwork to the pressure lines A & B ports
· Manifold valve splitter 4 lines
· Fluid Reservoir 50 gal (with sight gage and calibrated removable thermometer) cert paperwork
· Power is 460V/3PH 30 HP electric motor with a 50 foot power cord
· Test 4 double actuating cylinders, with individual lockout valves
· Pressure and Return line filtration
· Full unit containment/drip pan
· Steel frame with caster min 6”
· Frame and Reservoir corrosion control coating
· 0-6000 psi (spring kit included) automatic relief valves installed on ports A & B. Must have 3/8 NPT male thread on discharge side.
· Warranty 2 years on parts and labor
· Parts listing with part number and MFG
· Technical / operational manual image1.png