SOW HYDRAULIC TEST PUMP STAND.docx
DOCX document 87 KB Posted
- Attached to
- Hydraulic Pump Test Stand RFQ Federal contract opportunity
- Solicitation number
- N6852023R0016
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Hydraulic Pump Test Stand QA.docx | DOCX document | |
| Hydraulic Pump Test Stand QA.docx | DOCX document | |
| RFQ Full Text Clauses and Provisions.docx | DOCX document | |
| Hydraulic Pump Test Stand QA.docx | DOCX document | |
| Combined Synopsis Solicitation.docx | DOCX document | |
| RFQ Full Text Clauses and Provisions.docx | DOCX document | |
| SOW HYDRAULIC TEST PUMP STAND.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FLEET READINESS CENTER MID-ATLANTIC Voyage Repair Team, Mayport Florida Building 1613 Naval Station Mayport, Mayport Florida 32228
STATEMENT OF WORK FOR CONTRACTURAL PROCUREMENT OF JET BLAST DEFLECTOR HYDRAULIC TEST PUMP AND STAND (FY-23)
1. The FRCMA Voyage Repair Team (VRT), a source approved Department of the Navy ALRE ship repair facility has a requirement to procure a Hydraulic Test Pump Stand per the specifications below.
2. The following specifications are required on the new test pump:
· Pump Type - Piston Pump
· Max pressure 10,000 PSI
· Operating range 1000-6000 PSI
· Gage Panel, pressure gages are liquid filled ( request spare set) calibrated from an accredited calibration lab with cert paperwork
· Pressure controlled by a remote relief valve with a hand dial manual adjustment
· Pressure gages are liquid filled ( request spare set) calibrated from an accredited calibration lab with certification paperwork to the pressure lines A & B ports
· Manifold valve splitter 4 lines
· Fluid Reservoir 50 gal (with sight gage and calibrated removable thermometer) cert paperwork
· Power is 460V/3PH 30 HP electric motor with a 50 foot power cord
· Test 4 double actuating cylinders, with individual lockout valves
· Pressure and Return line filtration
· Full unit containment/drip pan
· Steel frame with caster min 6”
· Frame and Reservoir corrosion control coating
· 0-6000 psi (spring kit included) automatic relief valves installed on ports A & B. Must have 3/8 NPT male thread on discharge side.
· Warranty 2 years on parts and labor
· Parts listing with part number and MFG
· Technical / operational manual image1.png
File details come from the government source that posted it. Updated .