This is a Statement of Work for the procurement of pan/tilt positioner equipment by the Utah Test and Training Range (UTTR) at Dugway Proving Ground (DPG). The contractor shall furnish and deliver twelve (12) new TAA-compliant Quickset MPT-50 Model 8-JA100-MW6 Pan/Tilt Positioners with standard manufacturer documentation, firmware, operating manuals, accessories, and warranty information. The delivery deadline is no later than November 11, 2026. These units are required to replace existing 20-year-old Panasonic positioners that have become obsolete and lack manufacturer support. The equipment will support precision camera positioning for test and training missions.

Delivery must occur at UTTR/DET1 South, 1010 Avery Road, Dugway, Utah 84022 during normal duty hours (Monday–Thursday, 7:00 A.M. to 4:00 P.M.), with a minimum of 24 hours' notice required prior to delivery. The contractor must arrange delivery times with range personnel and provide driver's license information at least one business day in advance. Deliveries may not exceed the agreed-upon time of arrival by more than two hours without notifying the point of contact. Access restrictions apply; all employees must be U.S. citizens with valid government-issued identification and proof of vehicle insurance. The specifications for the Quickset MPT-50 include a 75-pound payload capacity, pan range of ±217.5°, tilt range of ±90°, 0.05° repeatability on both axes, operating temperature range of −32°C to +55°C, environmental classification IP67, and FCC regulatory compliance. Invoices must clearly display the contract number and delivery date.

View the file

Other files

File Type Posted
RFQ Combined Synopsis Solicitation.pdf PDF
Equipment List.xlsx XLSX spreadsheet
Redacted Brand Name Justification.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

PAN TILT POSITIONER

23 JULY 2026

1. BACKGROUND: The Utah Test and Training Range (UTTR) operates precision camera systems in support of test and training missions on Dugway Proving Ground (DPG). These missions require accurate camera positioning to support camera housing systems. The existing Panasonic pan/tilt positioners supporting these systems have been in service for more than 20 years. The equipment has become obsolete, manufacturer support is no longer available or is significantly limited, and replacement parts are increasingly difficult to obtain. Continued reliance on the existing systems creates risks and increases the potential for loss of camera positioning capability during critical test events. The UTTR requires replacement pan/tilt positioners for reliable positioning and preset functions.

2. SCOPE: The Contractor shall furnish and deliver twelve (12) new TAA Compliant, Quickset MPT-50 Model 8-JA100-MW6 Pan/Tilt Positioners and components, outlined in SOW Attachment A with standard manufacturer documentation, firmware, operating manuals, accessories, and warranty information required for complete operational capability.

3. PERIOD OF PERFORMANCE: Delivery shall occur no later than 11 November 2026.

4. DELIVERY INFORMATION: The Government reserves the right to restrict access to any contractor employee, or prospective contractor employee, who is identified as a potential threat to the health, general well-being, safety, security, or operational mission of the installation and its population. A background check will be performed prior to installation access (requires 24 hours’ notice).

Employees/Visitors must be US citizens, possess a valid government issued driver’s license or government ID, and vehicles must have valid proof of insurance for access to installation/work locations.

4.1. Dugway (South Range): The vendor must provide driver’s license information to the UTTR/DET1 no less than one business day prior to delivery. Delivery shall take place at UTTR/DET1 South at 1010 Avery Road Dugway, 84022. Dugway is approximately 94 miles from Salt Lake City, UT (45 miles west then south 49 miles) off 1-80 at Dugway/Rowley Exit 77. Be aware that you will be traveling through open-range country with horses and free-range cattle.

4.2. Delivery Date/Time: Contractor deliveries must be performed during normal duty hours, which are currently Monday through Thursday, 7:00 A.M.

to 4:00 P.M., no Friday, Saturday, Sunday, or Federal Holidays will be accepted. The contractor shall arrange and schedule deliveries with range personnel outlined in this SOW. A minimum of 24 hours’ notice is required prior to delivery. The contractor shall arrange a time of arrival with the staff outlined in this SOW for deliveries. Deliveries shall not exceed the agreed upon time of arrival by more than two hours without notifying the established point of contact.

5. REPORTS: The contract number and delivery date must be clearly visible on each invoice.

Quickset MPT-50 Model 8-JA100-MW6 Features and Specifications

35.4 lbs (16.1 kg)

11.44’ W x 12.55’H x 8.25’D

Stepper Motors, Hardened Steel Worm Gear Drive Material Aluminum 356-T6 Housing, Stainless Steel Hardware

Permanently Sealed Radial Ball Bearings

Operational Temperature -32°C to +55°C (100% RH)

Storage Temperature -40°C to +70°C

Duty Cycle Reading • Odometer-Both Axis (Total # of Degrees T CPU Temperature (Positioner Control Board) Voltage Measurement (I/P, 24V, 12V, 5V) Current Measurement (24V, 12V, 5V Supply)

Environmental Classification IP67

Regulatory Compliance FCC

Payload Ports 0

Payload Capacity 75 lbs

Pan Payload Torque

Pan Range of Motion Non-continuous Rotation (+/- 217.5°)

Pan Speed Range 0.005°- 50.0 °SEC

Pan Repeatability 0.05°

Tilt Payload Torque 50 ft-lbs

Tilt Range of Motion 180° (+/- 90°)

Tilt Speed Range 0.005°- 12.0 °SEC

Tilt Repeatability 0.05°

Positioning Resolution 0.01°

Position Feedback Incremental magnetic encoder on each axis of motion

Both Axes

Both Axes

Operating Voltage 24-28 VDC (default) • 28-32 VDC (via settings)

System Power Idle (heaters off): 0.7 A Continuous (heaters off): 4.0 A Peak (heaters off): 6.5 A Continuous (heaters on): 7.3 A Peak (heaters on): 9.7 A In-Rush: 44.0 A < 1.0 milliseconds

Weight (Without Payload)

Hard Limits (Mechanically Adj.)

Soft Limits (Software Adj.)

Powder Coat Paint (Standard) • White (RAL #9016)

Health & Usage Monitoring Features

16.7 ft*lbs

Exterior Finish

Dimensions

Drive System