General Features The model DH071 or DR071 grinder pump station is a complete unit that includes: the grinder pump, check valve, HDPE (high density polyethylene) tank, controls, and alarm panel. A single DH071 or DR071 is a popular choice for one, average single-family home and can also be used for up to two average single-family homes where codes allow and with consent of the factory.

•Ratedforflowsof700gpd(2650lpd)
•70gallons(265liters)ofcapacity

• Indoor or outdoor installation

• Standard outdoor heights range from 61 inches to 160 inches

The DH071 is the “hardwired,” or “wired,” model where a cable connects the motor controls to the level controls through watertight penetrations.

The DR071 is the “radio frequency identification” (RFID), or “wireless,” model that uses wireless technology to communicate between the level controls and the motor controls.

Operational Information Motor 1 hp, 1,725 rpm, high torque, capacitor start, thermally protected, 120/240V, 60 Hz, 1 phase

Inlet Connections 4-inch inlet grommet standard for DWV pipe. Other inlet configurations available from the factory.

Discharge Connections

Pumpdischargeterminatesin1.25-inchNPTfemalethread.Caneasilybe
adaptedto1.25-inchPVCpipeoranyothermaterialrequiredbylocalcodes.

Discharge

15gpmat0psig(0.95lpsat0m)
11gpmat40psig(0.69lpsat28m)
7.8gpmat80psig(0.49lpsat56m)

Accessories E/One requires that the Uni-Lateral, E/One’s own stainless steel check valve, be installed between the grinder pump station and the street main for added protection against backflow.

Alarm panels are available with a variety of options, from basic monitoring to advanced notice of service requirements.

The Remote Sentry is ideal for installations where the alarm panel may be hidden from view. NA0050P01 Rev D