OFFICE

120B

STORAGE

120C

M E

N

W O

M E

N

CORRIDOR

J A

N

CAFE

JAVA

120A

.0

.1

.1

.0

COFFEE

BAR

HALL

ROOM

COMMUNICATIONS

115C

H A

L L

CENTER

RECREATION

114B

ROOM

ELECTRICAL

RM

BOILER

R A

M P

U

S A

N

IT

A R

Y H

O T W

A T

E R

Ø

Ø

S A

N

IT

A R

Y C

O L

D W

A T

E R

Ø

P

IP

E S

X

IS

T

IN

G

P

IP

N

W

D N

DN25

DN20

DN40

DN32

DN40

DN20

D N

D N

D N

D N

DN32 DN25

DN25

DN15

DN15

DN15

DN15 DN15

DN15 DN15

D N

D N

DN15

DN15

DN15

D N

D N

DN20

DN20

DN15

DN15DN20

DN20

DN15

DN15

DN15

DN15

DN20

DN20DN25

DN25

D N

D N

DN15

DN15

D N

DN20

DN20DN15

DN15

MALE

ROOM

LOCKER

RM

BOILER

Plates Exchanger

Softener Water

INSTALLATION Nr BE215

PROJECT

Building Nr:

DRAWING TYPE

Date Scale

Sheet

20004

Replace water piping

Exixting situation

03/'20

R-CH-O2-19199-9J

R-CH-O2-19199-9J/1

40 2 6 8 10M networks Sanitary water piping

CW

HW

DOMESTIC COLD WATER SUPPLY/RETURN

eau froide sanitaire départ/retour

SW SOFTENED WATER NETWORK (12°Fr) réseau d'eau adoucie (12°Fr)

DOMESTIC HOT WATER SUPPLY/RETURN 12°Fr eau chaude sanitaire départ/retour 12°Fr

APO 09088

USAG BENELUX (NSSG)

CHIEVRES AIR BASE

105B

107B

107A

106B

106A

TRAINING

WEIGHT

MALE

ROOM

LOCKER

CORRIDOR

STORAGE

LAUNDRY

OFFICE

LIBRARY

LATRINE

HANDICAP

LIBRARY

LIBRARY

TRAINING

CARDI-VASCULAR

MALE

ROOM

LOCKER

FEMALE

ROOM

LOCKER

FEMALE

ROOM

LOCKER

SUBSTATION

HEATING

STORAGE

120C

M E

N

W O

M E

N

CORRIDOR

J A

N

CAFE

JAVA

120A

.0

.1

.1

.0

COFFEE

BAR

HALL

ROOM

COMMUNICATIONS

115C

H A

L L

CENTER

RECREATION

114B

ROOM

ELECTRICAL

RM

BOILER

R A

MALE

ROOM

LOCKER

Plates Exchanger

Softener Water

INSTALLATION Nr BE215

PROJECT

Building Nr:

DRAWING TYPE

Date Scale

/2

Sheet

20004

Replace water piping

Exixting situation

False ceiling and wall tiles

03/'20

R-CH-O2-19199-9J

R-CH-O2-19199-9J/2

FALSE CEILING TO BE DISMOUNTED AND RE-DONE

WALL TILES TO BE REMOVED AND RE-DONE

40 2 6 8 10M

APO 09088

USAG BENELUX (NSSG)

CHIEVRES AIR BASE

105B

107B

107A

106B

106A

TRAINING

WEIGHT

MALE

ROOM

LOCKER

CORRIDOR

STORAGE

LAUNDRY

OFFICE

LIBRARY

LATRINE

HANDICAP

LIBRARY

LIBRARY

TRAINING

CARDI-VASCULAR

MALE

ROOM

LOCKER

FEMALE

ROOM

LOCKER

FEMALE

ROOM

LOCKER

SUBSTATION

SAUNA SAUNA

STORAGE

120C

M E

N

W O

M E

N

CORRIDOR

J A

N

CAFE

JAVA

120A

.0

.1

.1

.0

COFFEE

BAR

HALL

ROOM

COMMUNICATIONS

115C

H A

L L

CENTER

RECREATION

114B

ROOM

ELECTRICAL

RM

BOILER

R A

S A

N

IT

A R

Y H

O T W

A T

E R

Ø

Ø

S A

N

IT

A R

Y C

O L

D W

A T

E R

Ø

P

IP

X

IS

T

IN

G

DN40 DN40

D N

DN25

DN15

DN20

DN15 DN15

D N

D N

DN20

DN25

DN15

DN15DN25

DN20

DN15

DN15

DN20

DN25

DN25

D N

DN15

DN15

DN15

DN15

MALE

ROOM

LOCKER

DN20

DN15

DN15

DN15

DN15

DN15

DN25

D N

D N

D N

D N

D N

D N

D N

D N

D N

DN25

D N

D N

D N

D N

DN50 DN50 DN50

DN50

DN25 DN25 DN25

DN25

D N

DN15

DN25

DN25

D N

D N

D N

D N

DN20

DN20

D N

DN25

DN15

DN15

DN25

Softener Water

DN25

E X

IS

T

IN

G S

A N

IT

A R

Y C

O L

D W

A T

E R

INSTALLATION Nr BE215

PROJECT

Building Nr:

DRAWING TYPE

Date Scale

Sheet

20004

Replace water piping

03/'20

R-CH-O2-19199-9J

R-CH-O2-19199-9J/3

40 2 6 8 10M networks Sanitary water piping

New situation

LIMITE D'ENTREPRISE

TIE IN POINT

CW

HW

DOMESTIC COLD WATER SUPPLY/RETURN

eau froide sanitaire départ/retour

SW SOFTENED WATER NETWORK (12°Fr) réseau d'eau adoucie (12°Fr)

DOMESTIC HOT WATER SUPPLY/RETURN 12°Fr eau chaude sanitaire départ/retour 12°Fr

-MULTILAYERS PEHD-ALU-PEHD

FOR De20=DN15 TO De63=DN50

-STAINLESS STEEL AISI304

FOR DN 50

-multicouches Pehd-alu-Pehd pour De20=DN15 jusque De63=DN50

-inox AISI 304 pour DN 50

APO 09088

USAG BENELUX (NSSG)

CHIEVRES AIR BASE

Softener Water fountain

Drinking water fountain

Drinking water

D N

D N

105B

107B

107A

106B

106A

TRAINING

WEIGHT

MALE

ROOM

LOCKER

CORRIDOR

STORAGE

LAUNDRY

OFFICE

LIBRARY

LATRINE

HANDICAP

LIBRARY

LIBRARY

TRAINING

CARDI-VASCULAR

MALE

ROOM

LOCKER

FEMALE

ROOM

LOCKER

FEMALE

ROOM

LOCKER

SUBSTATION

T

TO SEWAGE NETWORK

vers réseau égout

BMS

To sprinkler network

EAM

Adoucisseurs d'eau

WATER SOFTENERS

75KG

M

SPECS Nr 3-02-3-6(12°Fr)

BMS BMS

point de contrôle de dureté

HARDNESS CONTROL POINT

DN15

m h EA

D N

D N

1500l

Panels

Solar burner from circuit

Heating

M

80L

EXPANSION TANK

BMSBMSBMS

D N

BMS

BMS

BMS BMS BMS

F it n e s s

S a n it a r y lo o p

L a u n d r y

B u il d in g

O D

R

F it n e s s

S a n it a r y lo o p

L a u n d r y

B u il d in g

O D

R

D N

D N

D e

D e

D N

D N

D e

DN40

DN40

G a r a g e

D N

WATER NETWORK

FILING OF HEATING

D N

ODR

ECO Z 25/1-5

Wilo Stratos

2m3/h

WPHW176.3

1.5m3/h

WPHW176.3

2m3/h

WPHW176.3

Numérotation des accessoires

ACCESSORY NUMBER

FF=FIRE FIGHTING INTERNAL PIPEWORK (GALVANISED STEEL)

réseau d'eau adoucie (12°Fr)

SW=SOFTENED WATER NETWORK (12°Fr) eau chaude sanitaire départ/retour

HW=DOMESTIC HOT WATER SUPPLY/RETURN

eau froide sanitaire départ/retour

CW=DOMESTIC COLD WATER SUPPLY/RETURNE

Type de fluide

TYP OF FLUID

Légende de la numérotation

LEGEND OF NUMBERING SYSTEM

-Sonde thermostatique=THERMOSTAT SENSORTH

-Sonde de t°=TEMPERATURE SENSORTS

-Pressostat=PRESSOSTATPR

-Flow switch=FLOW SWITCHFS

-Circulateur=WATER PUMPWP

-Filtre=FILTERFI

-Clapet anti-retour=FLOW CHECK VALVEFC

-Soupape de sécuritéSV =SAFETY VALVE

-Vase d'expansion=EXPANSION TANKET

-Vanne d'isolement=INSULATION VALVEIV

-Vanne de réglage=BALANCING VALVEBV

-Vanne motorisée=MOTORISED VALVEMV

Type de matériel

TYP OF EQUIPMENT

Légende électrique

ELECTRIC LEGEND

ELECTRICAL PANEL

Tableau électrique connecté au BMS

Signalisation d'équipement

CONNECTED WITH BMS

SIGNALISATION OF EQUIPMENT

BMS

TTCW

IVHW IVHW IVHW IVHW IVHW IVHW IVHW

IVHW

IVHW

TSHW

THHW

FCHW

IVHW IVHW

SVCW

SVCW

IVHW IVHW IVHW

SVCW

FCSW

IVHW

T S

H W

IVHW IVHW IVHW

FCCW

TSCW

THCW

FCCW

TSCW

THCW

FCCW

TSCW

THCW

IVHWIVHWIVHW

IV

H

W

IVSW

IVCW

IVSW

IVSW

IVSW

IVSW

IV

C

W

FCSW

IVSW

BVCW IVCW

IV

C

W

IVCW

BVCW

FCCW

IV

C

W

IV

C

W

IV

C

W IVCW

IVCW

F

IC

W

IV

C

W

IVSW

500l 500l 500l

SANITARY

Sanitaires

VALVE

vanne

PIPE ON HOLD

tuyau en attente

INSPECTION FIT

regard de contrôle

ROOF PASSAGE (VENTILATION)

passage en toiture (ventilation)

KITCHEN SINK

évier de cuisine

SHOWER

douche

WC

wc

BUILT IN WASH BASIN

lavabos encastrés

WASH BASIN

lavabo apparent

MOP SINK OR UTILITY SINK

déversoir d'eau de nettoyage

FLOOR DRAIN

avaloir

SIPHON TYPE EVACUATION + FUNNEL

évacuation avec siphon + entonnoir

TIE IN POINT

point de connection (Limite d'entreprise)

MIXER TAP

mitigeur

T.I.

URINAL

urinoir

V.E.

M

Vanne motorisée de sécurité 2 voies

MOTORISED SAFETY 2 WAYS VALVE

EA

M réducteur/régulateur de pression

P

CW

HW

DOMESTIC COLD WATER SUPPLY/RETURN

eau froide sanitaire départ/retour

SW SOFTENED WATER NETWORK (12°Fr) réseau d'eau adoucie (12°Fr)

BATH

baignoire

DOMESTIC HOT WATER SUPPLY/RETURN 12°Fr eau chaude sanitaire départ/retour 12°Fr

-MULTILAYERS PEHD-ALU-PEHD

FOR De20=DN15 TO De63=DN50

-STAINLESS STEEL AISI304

FOR DN 50

-multicouches Pehd-alu-Pehd pour De20=DN15 jusque De63=DN50

-inox AISI 304 pour DN 50

FIRE POLES TYPE BH100

borne incendie type BH100

INSIDE FIRE POST-HOSE REEL 30m/DN25 AND DSP45 CONNECTION (WITHOUT CABINET) dévidoir incendie- enrouleur de flexible 30m/DN25 et raccord DSP45(sans armoire)

NON-RETURN VALVE

clapet anti-retour

VALVE NORMALLY CLOSED

vanne normalement fermée

Vanne motorisée à 3 voies

MOTORISED REGULATION 3 WAYS VALVE

filtre à tamis

WATER FILTER

débimètre

FLOW METER

point de vidange

DRAIN POINT

circulateur ou pompe simple

WATER PUMP

PRESSURE REDUCER / REGULATOR

NON-RETURN VALVE TYPE EA

clapet anti-retour de contrôle type EA agréé BEGAQUA filtre à rinçage automatique

AUTOMATIC RINSING FILTER

vase d'expansion

EXPANSION TANK

purgeur d'air

AIR PURGER

thermomètre

THERMOMETER

sonde de température

TEMPERATURE SENSOR

sonde de pression

PRESSURE SENSOR

DISCONNECTOR WITH UNDERPRESSURE

ZONE CONTROLLABLE AND REMOVABLE

FILTER (TYPE BA)

disconnecteur à zone de pression réduite contrôlable (type BA) agréé BELGAQUA avec filtre démontable

De( in mm )

DIAMETER

OUTSIDE

corresponding

21.3 20

26.9 26

33.7 32

42.4 40

48.3 50

60.3 63

76.1 NOT AVAILABLE

88.9 PEHD

114.3 110 pour réseau d'adduction :

FOR DISTRIBUTION NETWORKS :

les conduites en pehd et diamètres extérieurs De(mm)indiqué pour correspondance entre diamètre nominaux

PEHD PIPES

AND EXTERNAL DIAMETER De(in mm) INDICATE FOR

EQUIVALENCE BETWEEN NOMINAL DIAMETER (DN)

DN

DIAMETER

NOMINAL

( mm )

DIAMETER

OUTSIDE

corresponding

UBATC AGREED

PEHD/ALU/PEHD

ISO MEDIUM

STEEL

GALVANISED

(mm )

DIAMETER

OUTSIDE

corresponding

AISI 304

STEEL

STAINLESS

±76.1

±88.9

±114.3

160NOT USED NOT USED

BALANCING VALVE

vanne d'équilibrage manomètre

PRESSURE INDICATOR

M

NOT USED

NOT USED

NOT USED

NOT USED

NOT USED

NOT USED

HOSE BIB (DOUBLE SERVICE TAP )

Robinet double service

ON PLAN

sur plan

ON DIAGRAM

sur schéma

HAND SINK

lave-mains sur pied ou suspendu

MRF

FIRE RESISTANT FLEXIBLE STRIP FOR EXTERNAL DIAMETER SMALER THAN 40mm bande souple coupe-feu pour diamètres extérieurs inférieurs à 40mm

FIRE RESISTANT COLLAR FOR EXTERNAL DIAMETER EQUAL OR LARGER THAN 40mm manchons RF pour diamètres extérieurs supérieurs à 40mm

MRF

pour tuyauteries et robinetteries

Epaisseurs minimum d'isolation

FOR PIPES AND FITTINGS

MINIMAL INSULATION THICKNESS

>100

WOOL SHELLS

MINERAL

SHELLS

RUBBER

FOAM

SYNTHETIC

TANK 80 25

DN

DIAMETER

NOMINAL

(mm)

HOT WATER

DOMESTIC

(mm)

COLD WATER

DOMESTIC

T.I.

T.I. T.I.

SPECS Nr 3-02-1

G a r a g e

D e

IVHW

T o il e t s o f f ic e s id e

BMS

BMS

D e

1.5m3/h

WPHW176.3

IVHW

FCCW

TSCW

THCW

IVHW

T o il e t s o f f ic e s id e

T.I.

D N

IVSW

IVSW

T.I.

Toliets office side

FCCW

FCCW FCCW

IVCW

IVSW

FCSW

IV

C

W

INSTALLATION Nr BE215

PROJECT

Building Nr:

DRAWING TYPE

Date Scale

Sheet

20004

Replace water piping

03/'20

R-CH-O2-19199-9J

New situation diagram Heating room - Plumbing

R-CH-O2-19199-9J/4

APO 09088

USAG BENELUX (NSSG)

CHIEVRES AIR BASE

O2D-19199-9J - Replace water piping in bldg 20004-Model-000
O2D-19199-9J - Replace water piping in bldg 20004-Model-001
O2D-19199-9J - Replace water piping in bldg 20004-Model-002
O2D-19199-9J - Replace water piping in bldg 20004-Model-003

File details come from the government source that posted it. Updated .