CAPE COD CANAL
TRAVIS GERMANO
40 ACADEMY DRIVE
BUZZARDS BAY MA 02532-1555
TEL: 978-318-8550 FAX:
W13G86231965050001
REQUEST FOR QUOTATIONS
(THIS IS NOT AN ORDER) 1
PAGE OF PAGES
1. REQUEST NO. 2. DATE ISSUED RATING
W912WJ23Q0020 20-Dec-2022 5a. ISSUED BY
8. TO: NAME AND ADDRESS, INCLUDING ZIP CODE
IMPORTANT: This is a request for information, and quotations furnished are not offers. If you are unable to quote, please so indicate on this form and return it to the address in Block 5a. This request does not commit the Government to pay any costs incurred in the preparation of the submission of this quotation or to contract for supplies or services. Supplies are of domestic origin unless otherwise indicated by quoter. Any representations and/or certifications attached to this
Request for Quotations must be completed by the quoter.
11. SCHEDULE (Include applicable Federal, State, and local taxes)
ITEM NO.
(a)
SUPPLIES/ SERVICES
(b)
QUANTITY
(c)
UNIT
(d)
UNIT PRICE
(e) (f)
SEE SCHEDULE
AMOUNT
% No. %
NOTE: Additional provisions and representations [ ] are [ ] are not attached.
13. NAME AND ADDRESS OF QUOTER (Street, City, County, State, and ZIP Code)
14. SIGNATURE OF PERSON AUTHORIZED TO
SIGN QUOTATION
15. DATE OF
QUOTATION
16. NAME AND TITLE OF SIGNER (Type or print) (Include area code)
TELEPHONE NO.
AUTHORIZED FOR LOCAL REPRODUCTION STANDARD FORM 18 (REV. 6-95)
PREVIOUS EDITION NOT USABLE Prescribed by GSA FAR (48 CFR) 53.215-1(a)
THIS RFQ X[ ] IS [ ] IS NOT A SMALL BUSINESS SET-ASIDE
6. DELIVER BY (Date)
SEE SCHEDULE
AND/OR DMS REG. 1
UNDER BDSA REG. 2
4. CERT. FOR NAT. DEF.3. REQUISITION/PURCHASE
REQUEST NO.
U S ARMY ENGR DISTRICT, NEW ENGLAND
696 VIRGINIA RD
CONCORD MA 01742-2751
9. DESTINATION (Consignee and address, including ZIP Code)
7. DELIVERY
[ ]X FOB
DESTINATION
[ ] OTHER
(See Schedule)
11-Jan-2023(Date)
PLEASE FURNISH QUOTATIONS TO THE ISSUING OFFICE IN BLOCK 5a ON OR BEFORE CLOSE OF BUSINESS:10.
9783188255ANN M ADLEY
(Name and Telephone no.) (No collect calls)5b. FOR INFORMATION CALL:
d. CALENDAR DAYSc. 30 CALENDAR DAYSb. 20 CALENDAR DAYS12. DISCOUNT FOR PROMPT PAYMENT a. 10 CALENDAR DAYS
W912WJ23Q0020
Section B - Supplies or Services and Prices
INSTRUCTIONS TO OFFERORS
*SITE VISITS ARE HIGHLY RECOMMENDED PRIOR TO PROVIDING A QUOTE. SEE CLAUSE 52.236-27
ALT I FOR ADDITIONAL INFORMATION.
*PLEASE DIRECT QUESTIONS TO ANN MURPHY ADLEY AT (978) 318-8255 or
ANN.M.ADLEY@USACE.ARMY.MIL. ANY INFORMATION RECEIVED AT THE SITE VISIT WHICH
CONFLICTS WITH THIS SOLICITATION SHOULD BE BROUGHT TO THE ATTENTION OF ANN
MURPHY ADLEY. THE SOLICITATION AND RESULTING CONTRACT SHALL BE THE GOVERNING
DOCUMENT IN ALL CASES.
** QUOTES CAN BE E-MAILED TO ANN MURPHY ADLEY AT ANN.M.ADLEY@USACE.ARMY.MIL.
NOTE 1: In accordance with FAR Part 28.101-1(c), the Contractor will NOT be required to provide a Bid Guarantee.
NOTE 2: In accordance with FAR Part 28.102-1(b), the Contractor will be required to provide the following payment protections for all construction contracts greater than $150,000.00.
(i) Payment Bond or
(ii) Irrevocable Letter of Credit and
(iii) Performance Bond
A Payment Bond or Irrevocable Letter of Credit is the SELECTED payment protection for the Government. The penal amount of bond shall be 100% of the original contract price. If the contract price increases, the Government will require an increase in the penal sum of the existing bond. This bond shall be submitted to the Contracting Officer within 10 days after receipt of award.
A Performance Bond shall be required if the total price of the quote is greater than $150,000.00. The penal amount of the Performance Bond shall be 100% of the original contract price. If the contract price increases, the Government will require an increase in the penal sum of the existing bond. This bond shall also be submitted to the Contracting Officer within 10 days after receipt of award.
NOTE 3: In accordance with FAR Part 28.102-1(c), the Contractor will be required to provide one of the following payment protections for all construction contracts greater than $35,000.00 but not greater than $150,000.00.
(i) Payment bond or
(ii) Irrevocable letter of credit
A Payment Bond or Irrevocable Letter of Credit is the SELECTED payment protection for the Government. The penal amount of bond shall be 100% of the original contract price. If the contract price increases, the Government will require an increase in the penal sum of the existing bond. This bond shall be submitted to the Contracting Officer within 10 days after receipt of award.
NOTE 4:
QUOTATION INSTRUCTIONS:
1. If subcontractor will be used for this work, please provide company name:
2. In accordance with FAR Part 52.204-7(b)(1) Contractors must be registered in the System for Award Management (SAM) database (www.SAM.gov) to submit a quote (formerly the Central Contractor Registration
(CCR) database and the On-Line Representations and Certifications (ORCA)). Any reference to CCR or ORCA in any clause or provision is referring to the www.sam.gov website.
NOTE: SAM.gov registration takes approximately 3 weeks (DUNS registration 1-2 business days; CAGE code validation up to 10 business days; IRS validation and overall submission 7-10 business days). It is the contractor’s responsibility to track SAM.gov registration and follow-up with required tasks.
In addition, if you are registering a new entity in SAM.gov, you must provide an original, signed notarized letter stating that you are the authorized Entity Administrator. The Entity Administrator must establish a LOGIN.GOV account using the e-mail address that will be associated with the SAM registration. See https://www.gsa.gov/about-us/organization/federal-acquisition-service/office-of-systems-management/integrated-award-environment-iae/sam-update for additional information.
3. Provide business Unique Entity Identifier (UEI): _______________________________
4. Provide business CAGE code: __________________________________
5. Tax Identification Number: ___________________________________
6. Contractors shall provide completed FAR clause 52.204-8 (Annual Representations and Certifications) found in Section K of this solicitation with their quote if the Contractors have not completed their annual representations and certifications electronically via the SAM website at www.sam.gov. (See Paragraph 2 above).
7. Contractors are not required to submit an Accident Prevention Plan (APP) with their quote. The successful Contractor will be required to submit this document at the direction of the Technical Point of Contact. The APP must be accepted by the Government Designated Authority prior to the commencement of work.
POTENTIAL VENDORS ARE NOTIFIED THAT THE BASIS ON WHICH AWARD WILL BE MADE IS
PRICE ALONE.
ALL RESPONSIBLE SOURCES MAY SUBMIT A RESPONSE WHICH, IF TIMELY RECEIVED, MUST BE
CONSIDERED BY THE AGENCY.
INVOICES SHALL BE SENT TO TECHNICAL POINT OF CONTACT.
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
0001 1 Job CCC Septic System Replacement
FFP
Contractor shall provide all labor, equipment, materials, and transportation necessary to replace the septic system for a public bathroom facility located on Federal Property at the Cape Cod Canal Project, Sandwich, MA in accordance with the Statement of Work.
FOB: Destination
PURCHASE REQUEST NUMBER: W13G86231965050001
PSC CD: Y1QA
NET AMT
Section C - Descriptions and Specifications
STATEMENT OF WORK
REPLACE SEPTIC SYSTEM
CAPE COD CANAL PROJECT
U.S. ARMY CORPS OF ENGINEERS
STATEMENT OF WORK
SANDWICH, MA
I. General
1. Scope of work
Furnish all labor, equipment, and materials to replace the existing septic system for a public bathroom facility located on federal property at the Cape Cod Canal Project in Sandwich, MA. Work includes excavation and removal of the existing septic system that includes a septic tank, cast iron piping, distribution box, leach field with perforated pipe in trenches, and proper handling and disposal of approximately 725 cubic yards of leach field remediation waste (contaminated crush stone/soil). The replacement septic system shall match the dimensions and elevations of the existing system and be installed within the same footprint.
The new septic system shall include a 2,500-gallon precast concrete dual compartment septic tank, 4” PVC piping, concrete distribution box, leaching chambers, new leach field stone/sand, and other related items (to include, but not limited to repairing disturbed lawn, pavement, and curb areas back to original condition). All work shall be performed by a Massachusetts licensed septic system installer.
Work includes excavation within a park area that requires temporary fencing and restoring all disturbed areas to pre-existing conditions. Work includes trenching across existing paved areas that shall be patched. Contractor shall furnish all labor, equipment, materials, services, and tools necessary to replace and provide a fully functional septic system (See figures 1-10 and Photos 1-8). Attached drawings from 1976, sheets 2-6, show the as-built conditions of the existing septic system.
2. Locations
Sandwich Recreation Area is located at the end of 12 Freezer Road in Sandwich, MA 02563.
The work area is shown on Figures 1-4. There are Government maintained portable toilets located at the site that can be utilized by the contractor during field work. The public roads and parking areas are heavily used by the public. Work includes fencing, signage, barricades, and traffic control devices necessary to protect the general public from hazards within the work area.
3. Site Visits The project area is open to the public at any time. Interested vendors can inspect the existing conditions of the work area at any time. No extra payment will be allowed for perceived additional work caused by unfamiliarity with site conditions and requirements. A scheduled site visit will be provided for all interested vendors on January 5, 2023 at 10:00 am (refer to 52.236-27Alt 1) Contact the Technical Point of Contact to confirm attendance for site visit.
The Technical Point of Contact (TPOC) for the project is Travis Germano (978) 318-8550 or (Travis.J.Germano@usace.army.mil).
4. Schedule
The work shall be completed within 210 days from notice to proceed. The project area will be open to the contractor Monday through Friday, with work hours form 0700-1800. All work must be completed within the period of performance established by the Contract. No work shall be done on weekends or Government holidays.
5. Safety Requirements
a. General: All work shall be conducted in accordance with the U.S. Army Corps of Engineers (USACE) Safety and Health Requirements Manual (EM 385-1-1, most recent edition), and all applicable Occupational Safety and Health Administration (OSHA), federal, state, and local safety and health requirements. Perform work in a safe manner that protects both workers and the general public from hazards. All equipment shall be in good working order with all safety features as recommended by the manufacturer. A copy of EM 385-1-1 can be accessed at the project office or electronically at the following link:
https://www.publications.usace.army.mil/Portals/76/Publications/EngineerManuals/EM_ 385-1-1.pdf
Project staff reserve the right to cease work at any time should the safety of employees, Contractors, and/or the public become jeopardized.
b. Accident Prevention Plan: The contractor shall prepare an Accident Prevention Plan
(APP) specific to the activities being performed, at a minimum it must meet the requirements of EM 385-1-1, Appendix A. It shall include Activity Hazard Analyses (AHAs) as described below.
A preparatory meeting shall be conducted by the Prime Contractor to discuss the APP contents with all effected onsite employees. The Prime Contractor is responsible for informing the subcontractors of the safety provisions under the terms of the contract, the penalties for noncompliance, and inspecting subcontractor operations to ensure that accident prevention responsibilities are being carried out. Weekly safety meetings shall be held and documented. Records shall be available to the Technical Point of Contact upon request.
c. Activity Hazard Analysis: An AHA shall be submitted for each major phase of work. A major phase of work is defined as an operation involving a type of work presenting hazards not experienced in previous operations or where a new subcontractor or work crew is to perform the work. The analysis shall define all activities to be performed, identify the sequence of work, the specific hazards anticipated, and the control measures to be implemented to eliminate or reduce each hazard to an acceptable level. The AHA shall be continuously reviewed and revised to address changing site conditions as appropriate.
d. Required Personnel: The contractor shall employ a minimum of one Competent Person (CP) at each project site to function as the Site Safety and Health Officer (SSHO). The SSHO shall be onsite at all times during construction. The SSHO is required to have related construction experience and have at a minimum completed a 10 Hour OSHA training.
e. Accident Reporting: All accidents and near misses shall be investigated by the contractor and reported to the Technical Point of Contact immediately.
f. Daily Reports: The contractor shall provide daily production and QC reports, employee work hours, and certified payrolls electronically to the Technical Point of Contact.
g. COVID-19 Precautions: As part of the APP and AHAs include site specific COVID-19 monitoring procedures which address, at a minimum, recommended protocols, and mandates in accordance with Centers for Disease Control and Prevention (CDC) guidelines. Employee training on the signs, symptoms, and protection measures in accordance with CDC guidelines.
6. Preconstruction Conference
Prior to the start of any work, the contractor and Technical Point of Contact will schedule and conduct a “Preconstruction Conference”. The contractor’s staff responsible for quality and safety on the job site will attend this meeting. No work may be performed under this contract prior to this conference. The purpose of the conference is to enable the Technical Point of Contact to outline the requirements in terms of safety, quality, communications, inspections, material storage, submittals, and payments.
7. Permits
The work site is located on federal property, therefore USACE is responsible for permit requirements with local Board of Health and MassDEP. The contractor shall, without additional expense to the Government, be responsible for obtaining Septic Disposal Installers License and Septage Hauler Permit. The contractor shall comply with any applicable federal, state, county, and municipal laws, codes, and regulations in connection with the performance of the work specified under this contract.
8. Security
The contractor will comply with all established security policies at Cape Cod Canal Field Office. Potential periods of heightened security may affect access to work areas. During periods of heightened security, the Government reserves the right, at any time, to close any property and reschedule work. The contractor shall be given at least 24-hour notice of any such closure.
9. Contractor Conduct
The work area is located on federal property on a service road open to the public for recreation activities. Contractor and employees must act in a safe and professional manner at all times. Alcohol and firearms are prohibited on project grounds.
10. Payment Payment shall be made after final inspection and acceptance by the Government, the contractor must submit an invoice, utilizing Form ENG 93, to the Technical Point of Contact.
The invoice shall include the name of contractor (as per SAM registration), invoice date, contract number, description of work completed, and total amount due. For jobs greater than 30 days the contractor may request progress payments. Invoices may be mailed to:
US Army Corps of Engineers Cape Cod Canal Field Office P.O. Box 1555, Buzzards Bay, MA 02532 Attn: Travis Germano or email to travis.j.germano@usace.army.mil
II. Technical Requirements:
Part 1 General:
Contractor’s work includes all personnel, equipment, materials, supervision, and services necessary to replace the existing septic system as described herein. The new septic system shall be constructed to match the form, dimensions, grades, and functionality of the existing septic system. The system shall be installed by a licensed septic installer.
Requests for Information:
After Contract award, requests concerning the work of this project should be directed to the Technical Point of Contact at the Cape Cod Canal Office at (978) 318-8550 or travis.j.germano@usace.army.mil.
Submittals:
Contractor shall provide submittals that show pertinent details of proposed materials that allows confirmation the materials are in accordance with requirements listed in the materials section of this scope of work. Although the Government technically reviews submittals, the contractor’s work must be prosecuted using proper internal controls and review procedures. Contractor submittals must be reviewed and accepted by the government prior to the commencement of any field activities. Contractor shall provide required submittals to the Technical Point of Contact within 45 days of notice to proceed.
Required submittals include:
1. Accident Prevention Plan and Activity Hazard Analyses for all fieldwork.
2. Schedule
3. Work Plan and Traffic Control Plan – Provide a site plan with description of planned access points, storage of materials, and haul routes for trucks and equipment. Include description of signage, barriers, flashing barricade lights, traffic control devices and flaggers to protect the general public from hazards. Include the means and methods to control pedestrian, bike, and vehicular travel within the work areas.
4. Dewatering Work Plan
5. Septic Disposal Installers License and Septage Hauler Permit.
6. For all materials to be used on the project, the contractor shall provide the following information:
(1) Manufacturer’s name
(2) Catalog number
(3) Specifications
(4) Sieve analysis for all aggregates.
(4) Any other information necessary to approve the materials
(5) Safety Data Sheets (SDS) shall be submitted along with the product data for any potentially hazardous materials such as adhesives and flux materials.
7. Septic System Preliminary Drawing and As-Builts
Government Resources:
The contractor is responsible for providing all resources to complete the project. The Government will not provide any equipment or services.
Omissions:
This scope of work may not cover all specified activities, steps, and procedures required to supply the contract product. In case of omission, the normal industry, state, or federal standards, practices, specifications, and/or guides shall prevail. In no instance shall an omission be reason to produce less than an acceptable product.
Quality Control and Quality Assurance:
The contractor is responsible for the quality control of all work. The Government has the right to inspect and test all items called for by the contract, to the extent practicable at all times during the term of the contract.
Other Contracts:
The Government may undertake or award other contracts for additional work not related to this contract, the contractor shall fully cooperate with other contractors and Government employees.
The contractor shall not commit or permit any act, which will interfere with the performance of work by another contractor, or by Government employees.
Storage and Equipment Staging Areas:
Storage and equipment staging areas shall be coordinated with TPOC. The limits of the temporary work area are shown on Figure 3. Contractor is responsible to manage all storage of materials, dumpsters, and staging inside this work area. The contractor is responsible for receiving, unloading and movement of all materials. The contractor shall ensure that stored materials do not migrate into the waterway or onto roadways. Any materials that migrate into the waterway, roadways, sidewalks, bike paths, or recreation areas shall be cleaned up by the contractor daily. The Government is not responsible for damage or theft of contractor equipment or materials.
Clean Up:
The contractor shall practice good housekeeping to maintain a safe job site. The contractor shall keep the work area, including any storage areas, free from the accumulation of waste materials.
Upon completing work, the contractor shall remove all surplus excavation materials, broken pavement, old pipes, old manholes, tools, equipment, and materials, etc., that are not the property of the government and shall clean up the job site to the satisfaction of the government.
Contractor shall leave the entire site and areas adjacent in a neat and orderly condition.
Contractor shall clean up and properly dispose of debris off-site in accordance with federal, state and local ordinances and regulations
Sustainability:
EPA Designated: Under the Comprehensive Procurement Guidelines (CPG) program, the Environmental Protection Agency (EPA) designates products that are or can be made with recovered materials and recommends practices for buying these products. Any designated product that is being offered or supplied under this contract shall meet the minimum recommended content levels as identified under the CPG program. Visit https://www.epa.gov/smm/comprehensive-procurement-guideline-cpg-program for a complete list of designated products and the associated recommended contents levels. Offerors must be able to demonstrate that each offered products meets minimum content levels upon request.
Part 2 Materials:
1. Septic Tank - The septic tank shall be a 2,500-gallon monolithic precast reinforced concrete two compartment structure with inlet and outlet. The tank shall be watertight with embedded rubber seals and rated for H-20 loading. Inlet and outlet openings shall be provided with boot fittings to ensure watertight pipe installation with 4" PVC SCH 40 baffle tees. Provide an effluent filter on the outlet with minimum 1500 GPD, 1/16” slot size, 120 linear feet filtration, pipe size 4”, with floating ball. All precast/pipe construction joints and fittings shall be made watertight by parging with hydraulic cement. Tank, pipe openings, and risers shall be tested for watertightness. Septic tank shall have two watertight concrete manhole risers with cast iron frame and cover to grade. Septic tank construction and materials shall comply with MassDEP Title 5 regulations.
2. Distribution Box - Precast reinforced concrete distribution box with 5 outlets with embedded seals for 4” PVC pipe. Distribution box shall have one watertight concrete manhole riser with cast iron frame and cover to grade. All precast/pipe construction joints and fittings shall be made watertight by parging with hydraulic cement. Rated for H-20 loading.
3. Risers - Precast concrete manhole watertight riser sections.
4. Concrete – Shall be a minimum 4,000 psi compressive strength at 28 days.
5. Cast Iron Frame and Covers – Cast/Ductile Iron Manhole with “Sanitary” Badging
6. PVC Pipe Material - 4” diameter Schedule 40 PVC pipe with watertight cleaned and cemented joints.
7. Septic Leaching Chambers (5 trenches x 70’) – 12”x24” open-bottom, HDPE infiltration chamber that functions in permeable soils for subsurface leaching of septic effluent. Rated for H-10 loading.
8. Septic Leaching Chambers End Caps (10 Total/2 per trench) - HDPE infiltration chamber end cap. Connect ends with 4” SCH 40 PVC Pipe (Use top ports.)
9. Septic Leaching Chambers Observation Port (5 Total/1 per trench) - 10" round commercial grade irrigation valve box with round overlapping cover shall be a high-density structural foam polyethylene valve box and cover with UV inhibitors to prevent discoloration and cracking; box and cover color shall be green. Provide 4” Schedule 40 PVC Vertical Pipe w/ Screw in Cap connecting into HDPE infiltration chamber.
10. Leach Field Sand – Clean Title 5 PERC Sand. Clean granular sand, free from organic matter and deleterious substances. The contractor shall provide a sieve analysis of the Title 5 PERC Sand utilized for fill to verify that it meets the requirements of MA Sanitary Code 310 CMR
15.255 (3). Title 5 Sand fill shall comply with:
SIEVE SIZE PARTICAL SIZE % THAT MUST PASS SIEVE
#4 4.75 mm 100% #50 0.30 mm 10% - 100% #100 0.15 mm 0% - 20% #200 0.075 mm 0% - 5%
11. Select Fill - Clean granular sand free from organic matter and any deleterious substances.
Fill shall not contain any material larger than two inches.
12. Stone - No 6 Stone Aggregate.
13. Geotextile Fabric –– Non-woven geotextile made of polypropylene fibers.
14. Hot Mix Asphalt - Bituminous material shall be Massot Class 1 Hot Asphalt Mix (HMA) from a MassDOT approved local asphalt processing plant. Cold applied anionic asphalt emulsion tack coat material must meet ASTM specification D977 for grade RS-1. Reclaimed asphalt pavement (RAP) shall be limited to not exceed 10 percent of the total asphalt content.
15. Pavement Patch Subbase Material - Subbase material shall be densely graded soil or crushed stone material that drains well and is free of organic material, silt, and clay. Material that complies with MASSDOT Standard Specifications – Section 400 Sub-Base, Base Courses.
Subbase materials shall not include recycled pulverized pavement.
16. Topsoil – 3/8” Screened Loan Topsoil shall be from a local source that is clean, and free of weeds, litter, and brush with appropriate organic matter suited for growing grass.
17. Seed Mix – Provide seed mix for shoulder area in accordance with MassDOT Standard Specifications Section M6.03.0.
Part 3 Execution:
1. All onsite work shall be coordinated with the Technical Point of Contact prior to start of mobilization. The work area is located within a public recreation area on federal property at the Cape Cod Canal Project.
2. Contractor shall provide, erect, and maintain all necessary fencing, signs, barriers, flashing barricade lights, and safeguards required for public safety. Work shall be performed in a safe manner that protects both workers and the public from hazards. The work area is used extensively by the public for recreational activities that occur 24 hours per day. At the end of each workday the contractor shall ensure that the work area is left secured from public access.
3. The contractor shall employ ample personnel and sufficient equipment to accomplish the work of this contract in the least amount of time and be sequenced to minimize impacts on the public recreation area. Once excavation starts, contractor shall maintain an active daily presence onsite, prosecuting work continuously, without delay, and shall not demobilize nor vacate the work site until the project is complete. Soil stockpiles shall not remain onsite greater than 60 days.
4. In cases where work is not specifically shown or specified, contract shall include miscellaneous items, appurtenances, devices, and materials obviously necessary for a sound, secure, and complete installation of a new fully functional septic system.
5. All work areas are considered environmentally sensitive. Contractor shall inspect all equipment and materials used to prevent the release of any contaminants to the environment.
Prevent any sediment laden runoff from entering waterbodies, drainage inlets, and drainage areas from the pavement. Sediment controls may include, but are not limited to, entrenched staked straw bales, entrenched sediment (silt) fence, or compost filter socks. Remove all temporary sediment controls during final clean-up and prior to demobilization.
6. Existing Conditions: Contractor shall verify that actual site conditions are consistent with the existing conditions depicted within this statement of work. Discrepancies, omissions, and errors shall be reported to the government prior to the start of construction. Contractor shall be responsible for the protection of all existing structures, equipment, and areas from damage during construction. Any items that are damaged or altered during construction shall be restored to their pre-construction condition at the contractor’s expense and verified as such by the Government TPOC. Any disturbed areas outside of the sites to include the access roads and public roads shall be restored to the minimum of pre-existing conditions.
7. Location of underground utilities shown are approximate only and not all underground utilities may be shown. The contractor shall protect all underground utilities from damage throughout the duration of construction and be fully responsible for any and all damages.
The contractor shall call dig safe at 811 or 1-888-dig-safe not less than 72 hours prior to the start of any excavation for verification of underground utility locations. Contractor shall "Dig Safe" the work area prior to any subsurface work. Physically verify underground utility locations, including utility depth, by hand digging using wood or fiberglass handled tools when any adjacent construction work is expected to come within 3 feet of the underground system. The existing sewer line crosses several existing utilities, such as, but not limited to, underground electric and storm sewer lines. No utilities may be interrupted unless approved by the Government TPOC.
8. No portions of the proposed system are located with 100’ of wetlands.
9. Contractor shall coordinate inspection times with the TPOC 24-Hours in advance of the following inspections:
a. After excavation of all unsuitable material from soil absorption area.
b. Water tightness test for tank, sewer line, and distribution box.
c. Prior to covering/backfilling the constructed system.
d. After system backfill and final grading.
10. A Massachusetts License Professional Land Surveyor - shall field stake the new septic system and shall set a stable temporary benchmark as needed by the contractor. At least 48 hours prior to requesting a final inspection of the constructed system the installer shall prepare and provide the government with a preliminary sketch (by hand or cad) showing the final layout, elevations, pipe lengths, and inverts for the completed septic system. If preliminary sketch is approved, a final inspection by the government will be arranged with the installer within 24 hours of preliminary sketch approval. The system shall not be backfilled without written approval from the government.
11. Within 7 days from the date of the final inspection, the contractor shall submit to the government as-built drawing(s) that has been prepared and stamped by a Massachusetts licensed professional land surveyor The contractor shall also submit to the government the electronic cad files for the as-built drawing(s). The as-built drawing(s) shall show complete horizontal and vertical locations of all system components for the completed septic system, both above and below grade, including rim and invert elevations. The as-built drawing(s) shall also show final grades over the entire system.
12. The leaching area shall be covered within 2 working days following government inspection and approval.
13. Contractor to install magnetic tape above all components of septic system at a depth of 12 inches.
14. Heavy equipment shall not be driven over the leaching system area.
15. All work shall be completed in accordance with the Statement of Work. If any deviation is required, the Government shall be notified in writing and a formal modification to the Contract signed by the Contracting Officer shall be required prior to commencement of work.
16. All existing fill material shall be removed within footprint of the leaching trenches and 10 feet beyond edges of trenches. Use select fill as needed to replace fill material around system.
17. Contractor shall expect to encounter groundwater during excavation due to proximity of the canal. See attached “Form 11 – Soil Suitability Assessment for On-Site Sewage Disposal” report dated October 22, 2021, which indicates ground water table depth at elevation -8’ for test pit location 1 and elevation -11’ at test pit location 2. Contractor shall submit a dewatering work plan to complete the work in the dry.
18. Removal of the existing septic system and excavation - Contractor shall pump dry the existing septic tank and distribution box. Contractor shall remove and dispose of the existing 2,500-gallon concrete septic tank, subsurface cast iron pipe, concrete distribution box, three existing cast iron manholes and risers, leach field of perforated pipe, and leach field soil from the site in accordance with MassDEP Title 5 regulations. The trench required to remove the existing cast iron sewer line crosses a wood guardrail, paved parking lot, and granite stone curbing. The existing sewer line crosses several existing utilities, such as, but not limited to, underground electric and storm sewer lines. If the sewer line goes beneath any utility, contractor shall provide a temporary shoring of utility line prior to excavating. Contractor shall acquire TPOC approval of temporary shoring prior to proceeding. The contractor shall saw cut full depth all edges of the pavement for the trench. The wood railing and granite curbing shall be removed and re-installed to the form, fit and function of the pre-existing conditions after installation of new PVC sewer line. The existing leach field is 70’ long x 30’ wide with five trenches of 4” perforated pipe spaced 6’ apart. The five trenches are approximately 6 feet below the surface elevation. The contractor may use the excavated material above the existing leaching field for backfill to the maximum extent possible.
Contractor shall excavate and dispose of approximately 725 cubic yards of the existing contaminated leaching field crushed stone/soil from elevation -5’ to -11’ for area 80’ long x 40’ wide (10’ wider than existing footprint). The edges of all excavations shall be properly sloped, benched, and/or use a trench box for worker safety. Contractor shall ensure complete removal of the existing contaminated crushed stone/soil in leach field. All stones exceeding 2” in diameter, all loam, or foreign material encountered during excavation are to be removed from the leaching excavation area. Topsoil and general fill material that must be excavated above the system can be staged and reused or replaced with in-kind materials to backfill areas. All excavated waste materials to include the concrete tanks, piping and contaminated stone materials shall be properly handled by a licensed septage hauler and transported to an approved disposal location.
19. Install new septic tank - The new septic system shall be constructed to match the dimensions and elevation of the existing system. The new 2,500-gallon concrete septic tank shall have inlet and outlet pipe invert elevation of 12.50 feet and 12.25 feet respectively.
Tank shall be transit leveled with 6” of compacted crushed stone underneath. Contractor shall verify all invert elevations prior to backfilling. Septic tank shall be watertight with proper installation of butyl resin seals in joints of the tank (See figure 5). Backfill and compact granular fill in 6” lifts around the new installed tank and sewer line. Tie into existing 4” cast iron building sewer line within 2’ of building foundation wall with a watertight 4” cast iron to PVC flexible rubber connection coupling. Between the building and septic tank, install a 4” cleanout to grade with cast iron frame and cover (See figure 10).
20. Install new PVC pipe sewer line - The contractor shall install the new 4” PVC pipe to match the dimensions and elevations of the existing cast iron piping. A trench box shall be used in all trenches greater than 5 feet in depth. All pipes shall be laid on a firm base with all connections and joints mechanically sound and watertight. All piping shall be installed without any internal obstructions. Backfill and compact fill in 6” lifts. Magnetic marking tape shall be installed in the backfill material above the pipe at 12” below grade. The new sewer line pipe from the septic tank to distribution box shall be a minimum 1% slope.
Provide No. 6 crushed stone aggregate backfill around the new PVC pipe (See figure 7). C
21. Install new distribution box - The contractor shall install the new concrete distribution box to match the function and elevation of the existing distribution box. The inlet pipe invert elevation shall be 10.50 feet with five outlet pipes from the box. Box shall be transit leveled with 6” of compacted crushed stone underneath. Contractor shall verify the invert elevation prior to backfilling. Five new PVC outlet pipes shall be installed level from the distribution box to new leach field chambers (See figure 6).
22. Install new cast iron man-holes - Install 4 manholes with precast risers materials and cast-iron frame and covers. Three manhole locations at the septic tank and one at the distribution box. Manhole structures shall be installed complete, so covers are flush with finished grade elevation. Frame shall be set in full mortar bed (See figure 6 and 7).
23. Perform Water Tightness Test – Perform a hydrostatic water tightness test on the septic tank, sewer line, and distribution box.
Hydrostatic Testing Steps
a. Prior to backfill, seal the empty tank.
b. Seal access openings, risers, and inlet and outlet pipes.
c. Fill the empty tank with water to a point 2” below the top of the manhole riser. Let the tank stand for 1 hour. If there is a measurable drop in the water surface elevation, refill the tank and let the tank stand for 1 hour. The tank passes the water-tightness test once the water level is held for 1 hour without any measurable loss.
d. When leakage occurs and the tank can be repaired, the water-tightness test shall be made on the tank after repairs have been completed.
e. Repeat the process for the sewer line and distribution box.
f. The septic tank, sewer line, and distribution box must be inspected and certified as being water-tight by the TPOC.
24. Install new leach field - The contractor shall install the new leach field to match the function and dimensions of the existing 70-foot by 30-foot leach field. The new field shall include five trenches of HDPE Leaching Chambers spaced 6’ apart. Connect leaching chamber cap ends with 4” SCH 40 PVC Pipe. Provide 12” of No. 6 stone from the base to the top of the leaching chambers, wrapped in filter fabric (See figure 8). Provide one chamber observation port per leaching chamber trench (See figure 9). Provide approximately 125 cubic yards of No.6 stone aggregate backfill around the leaching chambers from elevation -5’ to -6’ for area 80’ long x 40’ wide (10’ wider than existing footprint). Provide approximately 600 cubic yards of clean sand for the new leaching field from elevation -6’ to -11’ for area 80’ long x 40’ wide (10’ wider than existing footprint). The contractor shall use the excavated material above the existing leaching field for backfill to the maximum extent possible.
25. Restore disturbed pavement areas – Provide a hot mix asphalt from a local source to patch the trench excavation across the paved parking area. Provide 6” of well compacted gravel base material under all pavement patch areas. A tack coat of liquid bituminous material shall be furnished and applied immediately prior to placement of the pavement. The transition from new asphalt pavement to the existing asphalt pavement shall be smooth. Pavement shall be compacted by rolling to a density of not less than 95% of the maximum density.
Pavement shall be minimum 3” thick after compaction. Hand compact in areas inaccessible to rolling equipment. Any depressions in pavement patches caused by settlement shall be corrected by the contractor at no additional cost to the Government.
26. Restore disturbed areas –All excavation areas shall be backfilled with compaction in layers. Restore areas to pre-existing conditions. Provide 4” of topsoil graded smooth and raked. Apply 5 lbs. of seed mix per 1,000 SF. Finished surface above the leaching area shall be graded to assure water runoff (2% minimum slope).
27. All workmanship shall be of the highest quality, and any excess of spilled sealant shall be removed from the pavement by approved methods and discarded. Any workmanship determined to be below the high standards of the particular craft involved will not be accepted, and will be corrected and/or replaced as required by the Owner.
28. Disposal: Local regulations regarding hauling and disposal shall apply. Contractor shall dispose of all debris resulting from the construction work. Contractor shall leave the entire site of the work in a neat and orderly condition. Debris, rubbish, non-hazardous waste, and non-usable material resulting from the work under this contract shall be disposed of by the contractor at his expense off Government property. Segregate and maximize recycling of all waste generated. Debris shall be removed and transported in such a manner that prevents damage to local roads and spillage.
29. Closeout Procedures: Contractor shall coordinate with the TPOC for the following at the completion of the project:
a. A final inspection walkthrough of the project, at which time, the contractor shall demonstrate to the TPOC that the work and system is fully operational and in compliance with the Statement of Work.
b. As-built drawings
c. Complete Final Payment Forms and Certifications.
Informational Photos:
Photo 1
Photo 1 – Shows existing conditions of septic leach field looking south. Government will remove garbage cans, picnic tables, and associated concrete pads.
Photo 2
Photo 2 Shows existing conditions of septic leach field looking south. Government will remove garbage cans, picnic tables, and associated concrete pads.
Photo 3
Photo 3 Shows existing conditions of septic leach field looking north. Government will remove garbage cans, picnic tables, and associated concrete pads.
Photo 4
Photo 4 Shows existing conditions of septic leach field looking west from D-box manhole to bathroom facility in the background.
Photo 5
Photo 5 Shows existing conditions of septic tank manholes looking east.
Photo 6
Photo 6 Shows existing conditions of septic tank manholes looking west.
Photo 7
Photo 7 Shows existing conditions of Soil Test Pit No. 1 with approximate ground water at -8’.
Photo 8
Photo 8 Shows existing conditions of Soil Test Pit No. 2 with approximate ground water at -11’.
REPLACE SEPTIC SYSTEM
Figure 1
Figure 1 Aerial Satellite Map - Shows general location of the Sandwich Septic System (Nearest
GPS address: 12 Freezer Road, Sandwich, MA 02563)
Figure 2
Figure 2 Aerial Satellite Map - Shows general location of the Sandwich Septic System (tank, sanitary line, and leach field).
Figure 3
Figure 3 Shows the limits of the construction area.
Figure 4
Figure 4 Shows the locations of the utilities within the work area. Please note the “high voltage” underground power line near/beneath the septic tank.
Figure 5
Figure 5 Shows the 2500 Gallon Dual Compartment Septic Tank Typical Detail
Figure 6
Figure 6 Shows the Distribution Box Detail
Figure 7
Figure 7 Shows the Typical Pipe Trench Detail
Figure 8
Figure 8 Shows the Septic Leaching Chamber Detail
Figure 9
Figure 9 Shows the Septic Leaching Chamber Observation Port Detail
Figure 10
Figure 10 Shows the Septic Sewer Cleanout and Cover Detail
Section F - Deliveries or Performance
DELIVERY INFORMATION
CLIN DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC /
CAGE
0001 210 dys. ANP 1 CAPE COD CANAL
TRAVIS GERMANO
40 ACADEMY DRIVE
BUZZARDS BAY MA 02532-1555
978-318-8550 FOB: Destination
961306
Section H - Special Contract Requirements
SECURITY REQUIREMENTS
General security requirements and guidance: The security requirements described below apply to all contract personnel (including employees of the prime Contractor (“Contractor”) and all subcontractor employees) supporting the performance requirements of this contract.
The Contractor is responsible for compliance with these security requirements. Questions regarding security matters shall be addressed to the designated Government representative (eg., Contracting Officer Representative (COR), Requiring Activity (RA) representative, or Contracting Officer (if a COR or other RA representative is not appointed)). Contract personnel are critical to the overall security and safety of US Army Corps of Engineers (USACE) installations, facilities and activities, and security awareness training contributes to those efforts. The Department of Defense (DoD) and Army security training requirements specified below, if applicable, are performance requirements; all applicable contract personnel shall complete initial training within 30 days of contract award or the date new contract personnel begin performance on the contract. Within five business days from the completion of training, the Contractor shall provide written documentation (e.g., email or memorandum) to the Government representative. The documentation shall include the names of contract personnel trained and which training they completed; the Contractor shall maintain training records as part of their contract files and be prepared to provide copies of training certificates to the Government representative. Contractor personnel and vehicles are subject to search when entering federal installations. Additionally, all contract personnel shall comply with Force Protection Condition (FPCON) measures, Random Antiterrorism Measures (commonly referred to as “RAMs”), and Health Protection Condition (HPCON) measures. The Contractor is responsible for meeting performance requirements during elevated FPCON and/or HPCON levels in accordance with applicable RA plans and procedures –this includes identifying mission essential and non-mission essential personnel. In addition to the changes otherwise authorized by the changes clauses of this contract, should FPCON or HPCON levels at any individual facility or installation change, the Government may implement security changes that affect contract personnel. The Contractor shall ensure all contract personnel are aware of their security responsibilities, including any site-specific requirements identified in local policies or procedures.
Suspicious Activity Reporting training (e.g. iWATCH, CorpsWatch, or See Something, Say Something): All contract personnel shall receive initial and annual refresher training from the RA representative on the local suspicious activity reporting program. This locally developed training provides contract personnel with general information on suspicious behavior, and guidance on reporting suspicious activity to the project manager, security representative or law enforcement entity.
WAGE DETERMINATION
"General Decision Number: MA20220001 11/18/2022
Superseded General Decision Number: MA20210001
State: Massachusetts
Construction Type: Building
Counties: Barnstable, Bristol, Dukes, Essex, Middlesex, Nantucket, Norfolk and Suffolk Counties in Massachusetts.
BUILDING CONSTRUCTION PROJECTS (does not include single family homes and apartments up to and including 4 stories)
Note: Contracts subject to the Davis-Bacon Act are generally required to pay at least the applicable minimum wage rate required under Executive Order 14026 or Executive Order 13658.
Please note that these Executive Orders apply to covered contracts entered into by the federal government that are subject to the Davis-Bacon Act itself, but do not apply to contracts subject only to the Davis-Bacon Related Acts, including those set forth at 29 CFR 5.1(a)(2)-(60).
|If the contract is entered |. Executive Order 14026 | |into on or after January 30, | generally applies to the | |2022, or the contract is | contract. | |renewed or extended (e.g., an |. The contractor must pay | |option is exercised) on or | all covered workers at | |after January 30, 2022: | least $15.00 per hour (or | | | the applicable wage rate | | | listed on this wage | | | determination, if it is | | | higher) for all hours | | | spent performing on the | | | contract in 2022. | |If the contract was awarded on|. Executive Order 13658 | |or between January 1, 2015 and| generally applies to the | |January 29, 2022, and the | contract. | |contract is not renewed or |. The contractor must pay all| |extended on or after January | covered workers at least | |30, 2022: | $11.25 per hour (or the | | | applicable wage rate listed| | | on this wage determination,| | | if it is higher) for all | | | hours spent performing on | | | that contract in 2022. |
The applicable Executive Order minimum wage rate will be adjusted annually. If this contract is covered by one of the Executive Orders and a classification considered necessary for performance of work on the contract does not appear on this wage determination, the contractor must still submit a conformance request.
Additional information on contractor requirements and worker protections under the Executive Orders is available at https://www.dol.gov/agencies/whd/government-contracts.
Modification Number Publication Date 0 01/07/2022 1 02/11/2022 2 02/18/2022 3 02/25/2022 4 03/04/2022 5 04/22/2022 6 05/06/2022 7 06/03/2022 8 07/08/2022 9 08/05/2022 10 08/12/2022 11 09/02/2022 12 10/07/2022 13 11/18/2022
ASBE0006-001 09/01/2022
Rates Fringes
Insulator/asbestos worker Includes the application of all insulating materials, protective coverings, coatings, and finishes to all types of mechanical systems
(ZONE A)...................$ 51.25 33.99
(ZONE B)...................$ 51.25 33.99
ZONES:
ZONE A
BARNSTABLE COUNTY (Brewster, Chatham, Dennis, Eastham, Harwich, Orleans, Provincetown, Truro, Wellfleet, Yarmouth) BRISTOL COUNTY (Easton), MIDDLESEX COUNTY, and NORFOLK COUNTY (Avon, Braintree, Brookline, Canton, Cohasset, Dedham, Dover, Foxborough, Holbrook, Medfield, Medway, Millis, Milton, Needham, Norfolk, Norwood, Quincy, Randolph, Sharon, Stoughton, Walpole, Wellesley, Westwood, Weymouth)
ZONE B
BARNSTABLE COUNTY (Barnstable, Bourne, Falmouth, Mashpee, Sandwich), BRISTOL COUNTY (All cities except Easton),and NORFOLK COUNTY (Bellingham, Franklin, Plainville)
ASBE0006-002 09/01/2021