Sign Att 2.0 Park Identity Sign Intent Drawings.pdf

PDF 4 MB Posted

Attached to
FABRICATE AND INSTALL HIGHWAY SIGNS FOR GETTYSBURG
Solicitation number
140P4220R0056
Issued by

View the file

Other files

File Type Posted
Questions-Answers_0002.docx DOCX document
Sol_140P4220R0056_Amd_0002.pdf PDF
Schedule of Signs Rev 01 - GPS coordinates_0002.xlsx XLSX spreadsheet
Combined Synopsis- Solicitation_0001.docx DOCX document
Sol_140P4220R0056_Amd_0001.pdf PDF
Sign Att 9 NPS Sign Program - Roadway Sign and Design Standards.pdf PDF
Sign Att 2.4 PMIS 245667 Road Guide Sign Intent Drawings.pdf PDF
Sign Att 3 PMIS 245667 Photos of Select Existing Signs.pdf PDF
Sign Att 4 NPS Sign Program Identity Manual.pdf PDF
Sign Att 2.5 PMIS 245667 Auto Tour Sign Intent Drawings.pdf PDF
Sign att 8 NPS Sign Program - Standard Motorist Grids.pdf PDF
Statement of Work.docx DOCX document
Sign Att 7 NPS Sign Program - Standard Motorist Guidance Details.pdf PDF
Sign Att 6 NPS Sign Program - Identity Panel Color Options.pdf PDF
Sign Att 5 NPS SIgn Program - ID Sign Grids.pdf PDF
FORM A.docx DOCX document
Sign Att 2.3 PMIS 245667 Path Finder Sign Intent Drawings.pdf PDF
Sign Att 2.1 Highway Guidance Sign Intent Drawings.pdf PDF
Sign Att 10 - PENNDot Details for Type A and Type C Post Mounted SIgns.pdf PDF
Sign Att 2.2 Park Boundary Sign Intent Drawings.pdf PDF
Wage Determination WD 15-4259 Rev. 12.pdf PDF
Technical Evaluation Factors.docx DOCX document
Past_Performance_Questionnaire Form B.doc DOC document
Sign Att 1 PMIS 245667 Schedule of Signs Rev 01.xlsx XLSX spreadsheet
Price Schedule.docx DOCX document
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

For the best experience, open this PDF portfolio in

Acrobat X or Adobe Reader X, or later.

Get Adobe Reader Now!

http://www.adobe.com/go/reader

Maintenance Facility Gettysburg National Military Park

Maintenance Facility

National Park Service U.S. Department of the Interior

GETT | Maintenance

Copyright 2005. All rights reserved. This document may not be reproduced in any form without prior written agreement with the U.S. Department of the Interior, National Park Service, Harpers Ferry Center, Office of NPS Identity. Drawings are for design intent only. Fabricator shall verify all mounting conditions and substrates. Fabricator is responsible for the engineering and structural integrity of all signs.

1.0

Production Notes

F/PI-1G, monolith, 1-sided, per NPS specifications. Sign to be mounted to stone base by others. Provide j-bolt location templates to the park.

3Sign Type 08-25-05

Revisions

Cap Height

Facility/Park ID Sign

Unit | Area

Scale

Quantity

3/4” = 1’ - 0”

UC = 6”

Dwg. Date

F/PI-1G

Sign Elevation

F/PI-1G, 6” Cap Height

45.25”

90”

106 ”

24”

24”

3”

U.S. Department of the Interior

Western Red Cedar Sign Panel with Routed Typography

NATIONAL

PARK

SERVICE

NATIONAL

PARK

SERVICE

Sign Top View

Sign Side View

GRAPHIC & COLOR

SPECIFICATIONS

Project:

Notes:

Drawing Description:

Typestyle:

Color Specifications:

RaidX/NPS/All Parks/G/GETT/Sales Orders/1000502/Drawings/3.2 PID.ai

N/A

SIGN ELEVATION

1 1/2" = 1' - 0"

1000502

Todd Turner

Mike Sarver

12.27.06

As Noted

F/PI-2G

Custom

SIGN FACE:

POST AND BASEPLATE:

Bottom Half:

Top Half:

Graphics:

B.M. 5/E 1000 Northwood Brown - Flat B.M. 2139-10 River Rock - Flat B.M. 2143-50 Old Prairie - Soft Gloss

B.M. 2139-10 River Rock - Flat

NPS Rawlinson Roadway Frutiger Bold

68” 6”

3/

4” 1 5/16”

13/16”

2 3/8”

/4

/2

/1

.333” ROUTED DADO

.125” DEEP

2”

3.2 | PID

0506-207-GETT

GRAPHIC & COLOR

SPECIFICATIONS

Project:

Notes:

Drawing Description:

Typestyle:

Color Specifications:

47.1

3.2 | PID

0506-207-GETT

RaidX/NPS/All Parks/G/GETT/Sales Orders/1000502/Drawings/3.2 PIDa.ai

N/A

Mike Sarver

12.27.06

Custom

SIGN FACE:

POST AND BASEPLATE:

Graphics:

B.M. 2139-10 River Rock - Flat B.M. 2143-50 Old Prairie - Soft Gloss

B.M. 2139-10 River Rock - Flat

NPS Rawlinson Roadway Frutiger Bold

68”

SIGN TYPE : 3.2 PID - ELEVATION : SIDE A

3/4" = 1' - 0"

A 53a

SIDE VIEW

A.1

SIDE B

A.2

/2

1/8" POST CAP

This drawing was prepared in accordance with information submitted. Changes to drawings may incur charges as stated in the price list.

Signed approval of submitted drawing is required prior to manufacture. Approval of drawing acknowledges that it is correct and supercedes all previous sets of drawings and/or specifications related to this order.

Any changes, corrections or remakes of products manufactured in accordance to approved drawings will be at purchaser's expense. Confidential and proprietary information of Bunting Graphics, Inc. may not be used or reproduced without Bunting's prior written consent. No part of this drawing, design, arrangement or idea thereon shall be duplicated or used for any purpose without express written permission of Bunting Graphic.

Bunting is not responsible for furnishing Primary Electrical Service to sign locations. Use Drawing File for Production 3

4.0 | GETT

0706-245-GETT

NPS

Gettysburg NMP

12.07.06

FI-2G(M)

32” x 12”

Ondrej Konvalinka

Alumalite

Vinyl

Painted

X/NPS/All Parks/G/GETT/S.O./1000502/Drawings/4.0.ai

Standard “Z” Mounting Rails

White Reflective

PMS 7531 Brown PMS 449 Green

NPS Rawlinson

SCALE: 3" = 1' - 0"

32"

3/8” RADIUS

1" 2"

This drawing was prepared in accordance with information submitted. Changes to drawings may incur charges as stated in the price list.

Signed approval of submitted drawing is required prior to manufacture. Approval of drawing acknowledges that it is correct and supercedes all previous sets of drawings and/or specifications related to this order.

Any changes, corrections or remakes of products manufactured in accordance to approved drawings will be at purchaser's expense. Confidential and proprietary information of Bunting Graphics, Inc. may not be used or reproduced without Bunting's prior written consent. No part of this drawing, design, arrangement or idea thereon shall be duplicated or used for any purpose without express written permission of Bunting Graphic.

Bunting is not responsible for furnishing Primary Electrical Service to sign locations. Use Drawing File for Production 33

50.1 | GETT

52” x 36”

X/NPS/All Parks/G/GETT/S.O./1000502/Drawings/50.1.ai

Frutiger

SCALE: 1 1/2" = 1' - 0"

52"

1/

8"

1/

2" 4"

This drawing was prepared in accordance with information submitted. Changes to drawings may incur charges as stated in the price list.

Signed approval of submitted drawing is required prior to manufacture. Approval of drawing acknowledges that it is correct and supercedes all previous sets of drawings and/or specifications related to this order.

Any changes, corrections or remakes of products manufactured in accordance to approved drawings will be at purchaser's expense. Confidential and proprietary information of Bunting Graphics, Inc. may not be used or reproduced without Bunting's prior written consent. No part of this drawing, design, arrangement or idea thereon shall be duplicated or used for any purpose without express written permission of Bunting Graphic.

Bunting is not responsible for furnishing Primary Electrical Service to sign locations. Use Drawing File for Production 42

64.0 | GETT

56” x 38”

X/NPS/All Parks/G/GETT/S.O./1000502/Drawings/64.0.ai

56"

7"

7/

This drawing was prepared in accordance with information submitted. Changes to drawings may incur charges as stated in the price list.

Signed approval of submitted drawing is required prior to manufacture. Approval of drawing acknowledges that it is correct and supercedes all previous sets of drawings and/or specifications related to this order.

Any changes, corrections or remakes of products manufactured in accordance to approved drawings will be at purchaser's expense. Confidential and proprietary information of Bunting Graphics, Inc. may not be used or reproduced without Bunting's prior written consent. No part of this drawing, design, arrangement or idea thereon shall be duplicated or used for any purpose without express written permission of Bunting Graphic.

Bunting is not responsible for furnishing Primary Electrical Service to sign locations. Use Drawing File for Production 43

65.0 | GETT

F/PI-1G

70” x 30”

X/NPS/All Parks/G/GETT/S.O./1000502/Drawings/65.0.ai

70"

7"

5/

8"

File details come from the government source that posted it. Updated .