SHOOTING RANGE _ DRAWINGS.pdf
PDF 12 MB Posted
- Attached to
- 26-026
- Solicitation number
- PE-65700-NONST-2026-000000096
- Issued by
- Fayette County, Georgia
About this file
This is a construction drawings document for the Floyd County Board of Commissioners in Rome, Georgia, related to the development of a Shooting Range & Training Center for the Floyd County Police Department. The drawings provide detailed architectural and structural specifications for the facility, including floor plans, elevation views, and construction details necessary for qualified contractors to prepare accurate bids. The project encompasses the complete design and construction requirements for a law enforcement training facility, with all specifications and required documentation available in the public files section of the contract solicitation.
The drawings serve as the technical foundation for the sealed bidding process, enabling contractors to assess scope, materials, labor requirements, and associated costs for project completion. Contractors must reference these plans in conjunction with other contract documents, including the Scope of Work and any addenda issued during the bidding period, to ensure comprehensive understanding of all project requirements and deliver competitive, compliant proposals to the Floyd County Board of Commissioners.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 26_026 SHOOTING RANGE _ TRAINING CENTER _ FCP.pdf | ||
| BID PRICE SUBMISSION FORM.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CIVIL SHEET INDEX
C001 COVER SHEET
C101 EXISTING CONDITIONS
C201 SITE PLANS
C301 GRADING PLANS
C501 EROSION CONTROL PLAN
C502 EROSION CONTROL NOTES & DETAILS
C503 VEGETATION PLAN
C601 PREDEVELOPED DRAINAGE MAP
C602 POST DEVELOPED DRAINAGE MAP
PROPOSED SHOOTING RANGE
1 POLICE PLAZA
ROME, GA 30165
FLOYD COUNTY BOARD OF COMMISSIONERS
12 E. 4TH AVE
ROME, GEORGIA 30161
DATE: MAY 1ST, 2026
LAND LOT 85, 23RD DISTRICT
CONSTRUCTION DOCUMENTS FOR:
ENGINEER:
HIGGINS & BURNS, LLC
JEFF BURNS, P.E.
P.O. BOX 384
ARMUCHEE, GA 30105
TELEPHONE: 706-766-3698
EMAIL: BURNSCIVILENGINEERING@GMAIL.COM
TOTAL SITE AREA = 10.25 ACRES
TOTAL AREA OF DISTURBANCE = 0.41 ACRES
24 HOUR CONTACT
RYAN DAVIS
678-733-1618
HB2025-21
PR
O
PO
SE
D S
H O
O
TI
N G
R
AN
G E
P R
O
JE
C T
FO
R
PROJECT NUMBER
REVISIONS
E . 4
TH
A
VE
R
O M
E, G
A
S H
EE
T
TI
TL
E
SHEET NUMBER
FL
O
YD
C
O U
N
TY
B O
AR
D
O F
CO
M
M
IS
SI
O
N
ER
S
P.
O
. B O
X
A R
M U
CH
EE
, G A
-5
-5
R
YA
N
R
W H
IG
G
IN
S.
N
ET
P
O
LI
CE
P
LA
ZA
R O
M E, G A
CO
VE
R
Jeff Burns Digitally signed by Jeff Burns
DN: C=US,
E=BurnsCivilEngineering@gmail.com, O="Higgins & Burns, LLC", CN=Jeff Burns Date: 2026.05.01 15:57:12-04'00'
P P P P P P P P P P P P P P P
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SSSSSSSSSS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SSSSSSSS
SS
SS
SS
SS
SS
SS
SS
SSSSSSSSSSSSSSSS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
40 40 80 120 FEET
SCALE: 1" = 40'
24 HOUR CONTACT
RYAN DAVIS
678-733-1618
HB2025-21
PR
O
PO
SE
D S
H O
O
TI
N G
R
AN
G E
P R
O
JE
C T
FO
R
PROJECT NUMBER
REVISIONS
E . 4
TH
A
VE
R
O M
E, G
A
S H
EE
T
TI
TL
E
SHEET NUMBER
FL
O
YD
C
O U
N
TY
B O
AR
D
O F
CO
M
M
IS
SI
O
N
ER
S
P.
O
. B O
X
A R
M U
CH
EE
, G A
-5
-5
R
YA
N
R
W H
IG
G
IN
S.
N
ET
P
O
LI
CE
P
LA
ZA
R O
M E, G A
EX
IS
TI
N
G
CO
N D
IT
IO
N S
DEMOLITION NOTES:
1. CONTRACTOR SHALL OBTAIN ALL PERMITS BEFORE DEMOLITION AND
CONSTRUCTION BEGINS. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING
WITH FLOYD COUNTY REGULATIONS, O.S.H.A. STANDARDS, AND GOVERNING EPA
REGULATIONS.
2. CONTRACTOR TO COMPLY WITH LOCAL AND COUNTY REGULATIONS REGARDING
HAULING, DISPOSAL, AND THE BURNING OR BURYING OF DEBRIS ON-SITE.
3. DEMOLITION MATERIALS NOT SUITABLE FOR FILL MATERIAL SHALL BE DISPOSED
OF OFF-SITE. ALL DEBRIS SHALL BE HAULED OFF-SITE TO A DISPOSAL AREA
APPROVED BY FLOYD COUNTY AND STATE OF GEORGIA FOR THE HANDLING OF
DEMOLITION DEBRIS.
4. THE LOCATIONS OF EXISTING UTILITIES SHOWN ARE BASED ON A SURVEY AS
INDICATED IN THE GENERAL NOTES ON THE SITE PLAN. CONTRACTOR SHALL NOTIFY
ENGINEER OF ANY DISCREPANCIES BETWEEN THESE PLANS AND FIELD
CONDITIONS.
5. CONTRACTOR SHALL CONTACT ALL UTILITIES COMPANIES (WATER, SEWER,
POWER, TELEPHONE, NATURAL GAS, CABLE, ETC) FOR PROPER DISCONNECT OF
UTILITIES TO BUILDING TO BE REMOVED, AS WELL AS VERIFICATION OF UTILITIES TO
BE RELOCATED DUE TO CONSTRUCTION. CONTRACTOR TO CALL GEORGIA ONE-CALL
CENTER @ 811 AT LEAST 72-HOURS PRIOR TO CONSTRUCTION TO HAVE UTILITIES
LOCATED.
6. CONTRACTOR RESPONSIBLE FOR LOCATING, IDENTIFYING, DISCONNECTING, AND
SEALING OR CAPPING UTILITIES SERVING BUILDINGS AND STRUCTURES TO BE
DEMOLISHED.
7. THE PURPOSE OF THIS PLAN IS FOR DEMOLITION ONLY. UTILITIES SHALL NOT BE
REMOVED, ABANDONED OR RELOCATED UNTIL ALTERNATE PROVISIONS ARE MADE
TO MAINTAIN SERVICE TO OTHER BUILDINGS/FACILITIES AS APPROVED BY THE
OWNER.
8. CONTRACTOR SHALL PROTECT ALL ADJACENT LANDS FROM DAMAGE DURING
DEMOLITION WORK. ANY OFF-SITE AREAS DISTURBED SHALL BE RETURNED TO A
CONDITION EQUAL TO OR BETTER THAN THE EXISTING CONDITION.
9. CONTRACTOR TO COORDINATE WITH OWNER ON STAGING OF ENTRANCE DRIVES
IN ORDER TO ALLOW EXISTING BUSINESS TO REMAIN OPERATIONAL.
10. BOUNDARY SURVEY & SITE TOPOGRAPHIC INFORMATION PROVIDED BY ROBERT
CANON, P.L.S.
11. UTILITY LOCATIONS SHOWN HEREON ARE BASED ON FIELD OBSERVATIONS AND
MAY NOT BE COMPLETE OR ACCURATE. CONTRACTOR SHALL FIELD VERIFY EXISTING
UTILITY LOCATIONS AND CONTACT 811 PRIOR TO COMMENCEMENT OF ANY
GROUND DISTURBING ACTIVITY.
52.9'
10'
SS
SS
SS
SS
SSSSSSSSSS
SS
SS
SS
SS
SS
46'
60'
130.3'
36.7'
70.3'
9.6'
30.8'
58.5'
7.6'
SS
SS
SS
SS
SS
SS
SS
SSSS
SS
SS
SS
W W W
20 20 40 60 FEET
SCALE: 1" = 20'
24 HOUR CONTACT
RYAN DAVIS
678-733-1618
HB2025-21
PR
O
PO
SE
D S
H O
O
TI
N G
R
AN
G E
P R
O
JE
C T
FO
R
PROJECT NUMBER
REVISIONS
E . 4
TH
A
VE
R
O M
E, G
A
S H
EE
T
TI
TL
E
SHEET NUMBER
FL
O
YD
C
O U
N
TY
B O
AR
D
O F
CO
M
M
IS
SI
O
N
ER
S
P.
O
. B O
X
A R
M U
CH
EE
, G A
-5
-5
R
YA
N
R
W H
IG
G
IN
S.
N
ET
P
O
LI
CE
P
LA
ZA
R O
M E, G A
SH
O
O
TI
N G
R
AN
G E
NOTE:
BUILDING DIMENSIONS SHOWN FOR LAYOUT
PURPOSES ONLY. REFER TO ARCHITECTURAL
PLANS FOR EXACT BUILDING DIMENSIONS.
UTILITY CONNECTIONS:
CONTRACTOR TO COORDINATE WITH INDIVIDUAL UTILITY OWNERS AND
ARCHITECTURAL PLANS TO DETERMINE LOCATION OF UTILITY CONNECTIONS
TO SERVE THE PROPOSED BUILDING.
2. SANITARY SEWER MATERIAL SHALL MEET THE MINIMUM REQUIREMENTS BELOW:
SDR 26 PVC (FOR DEPTH'S BETWEEN 0' AND 15') PER ASTM D3034;
OR DUCTILE IRON PIPE (DEPTHS GREATER THAN 15') PER ASTM A746 & AWWA C150.
MATERIAL NOTES
SITE NOTES:
1. ALL WORK AND MATERIALS SHALL COMPLY WITH THE
FLOYD COUNTY AND STATE OF GEORGIA REGULATIONS
AND CODES, AS WELL AS ALL O.S.H.A. STANDARDS.
2. SITE TOPOGRAPHY & BOUNDARY SURVEY PROVIDED
BY ROBERT CANON, P.L.S.. UTILITIES LOCATIONS
SHOWN HEREON ARE BASED ON FIELD OBSERVATION
AND MAY NOT BE COMPLETE OR ACCURATE. PROPERTY
IS ZONED O-I.
3.
4. CONTRACTOR SHALL OBTAIN ALL PERMITS BEFORE
CONSTRUCTION BEGINS.
5. ALL SIGNAGE SHALL COMPLY WITH FLOYD COUNTY
ZONING ORDINANCE.
6. CONSTRUCTION EQUIPMENT SHALL NOT BE PARKED
IN RIGHT-OF-WAY, AND MUST BE STORED WITHIN THE
SITE. CONSTRUCTION EQUIPMENT SHALL NOT BE
PARKED IN AREAS WHICH RESTRICT SIGHT DISTANCE.
7. CONTRACTOR SHALL NOTIFY ENGINEER SHOULD ANY
FIELD CONDITIONS BE NOTED THAT DIFFER FROM THE
SURVEY.
8. THERE ARE NO STATE WATER OR WETLANDS LOCATED
ONSITE OR WITHIN 200' OF THE PROPERTY.
9.
SI
TE
P
LA
N
SS
SS
SS
SS
SSSSSSSSSS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SSSS
SS
SS
SS
W W W
20 20 40 60 FEET
SCALE: 1" = 20'
24 HOUR CONTACT
RYAN DAVIS
678-733-1618
HB2025-21
PR
O
PO
SE
D S
H O
O
TI
N G
R
AN
G E
P R
O
JE
C T
FO
R
PROJECT NUMBER
REVISIONS
E . 4
TH
A
VE
R
O M
E, G
A
S H
EE
T
TI
TL
E
SHEET NUMBER
FL
O
YD
C
O U
N
TY
B O
AR
D
O F
CO
M
M
IS
SI
O
N
ER
S
P.
O
. B O
X
A R
M U
CH
EE
, G A
-5
-5
R
YA
N
R
W H
IG
G
IN
S.
N
ET
P
O
LI
CE
P
LA
ZA
R O
M E, G A
G R
AD
IN
G
D R
AI
N
AG
E
PL
AN
SH
O
O
TI
N G
R
AN
G E
GRADING NOTES:
1. ALL AREAS TO RECEIVE PAVEMENT, STRUCTURES OR FILL MATERIAL SHALL BE STRIPPED OF ORGANIC
MATERIAL, TOPSOIL, AND DEBRIS PRIOR TO CONSTRUCTION.
2. ONCE STRIPPING HAS BEEN COMPLETED, ALL AREAS TO RECEIVE FILL SHOULD BE PROOF-ROLLED IN THE PRESENCE OF A REPRESENTATIVE OF THE SOILS ENGINEER. SOFT AREAS ENCOUNTERED DURING
PROOF-ROLLING SHALL BE STABILIZED BY COMPACTION OR UNDERCUT.
3. ALL FILL AREAS SHALL BE FREE OF ORGANIC OR OTHERWISE UNSUITABLE MATERIALS AND
COMPACTED TO 95% OF MAXIMUM DRY DENSITY PER STANDARD PROCTOR ASTM D698 UNLESS
OTHERWISE SPECIFIED BY THE GEOTECHNICAL REPORT AS LISTED BELOW. THE TOP TWO (2) FEET OF FILL UNDER STRUCTURES AND PAVEMENT SHALL BE COMPACTED TO 98% OF MAXIMUM DRY DENSITY PER STANDARD PROCTOR ASTM D698 UNLESS OTHERWISE SPECIFIED BY THE GEOTECHNICAL REPORT
AS LISTED BELOW.
4. EARTHMOVING OPERATIONS SHALL BE PERFORMED IN ACCORDANCE TO THE GEOTECHNICAL
COMPACTION RECOMMENDATIONS, SEE "GEOTECHNICAL EXPLORATION AND FOUNDATION
RECOMMENDATIONS" REPORT PREPARED BY AHLBERG ENGINEERING, INC., DATED MARCH 23, 2026.
5. ALL SITE PREPARATION SHOULD BE MONITORED BY A REPRESENTATIVE OF THE GEOTECHNICAL ENGINEER. INSPECTIONS AND TESTING FOR ALL UNDERCUT AND FILL OPERATIONS AS WELL AS THE UTILIZATION OF ACCEPTABLE OFF-SITE BORROW MATERIALS SHOULD BE PERFORMED. THE OWNER, AT HIS OPTION, MAY HAVE DENSITY TESTS PERFORMED TO VERIFY THAT SPECIFIC COMPACTION IS
OBTAINED.
6. CUT OR FILL SLOPE SHOULD NOT BE STEEPER THAN 2H:1V. ALL PROPOSED SLOPES SHOULD BE OVERBUILT AND CUT BACK TO THE PROPOSED GRADES, EXPOSING THE FIRM COMPACTED INNER CORE.
THE EXCAVATION FOR THE SLOPES SHOULD BE MONITORED BY A REPRESENTATIVE OF THE
GEOTECHNICAL ENGINEER. VERTICAL CUTS EXCEED 5 FEET SHOULD BE BRACED AS REQUIRED BY OSHA
REGULATIONS FOR SAFETY.
7. SPOT ELEVATIONS SHALL TAKE PRECEDENCE OVER CONTOURS AND SLOPES SHOWN. THE
CONTRACTOR SHALL NOTIFY THE ENGINEER OF SPOT ELEVATIONS WHICH DO NOT APPEAR TO BE
CONSISTENT WITH THE CONTOURS AND SLOPES.
8. CONTRACTOR SHALL INSTALL APPROPRIATE EROSION CONTROL MEASURES PRIOR TO ANY LAND
DISTURBANCE ACTIVITIES.
9. THE CONTRACTOR SHALL ADJUST ALL MANHOLE COVERS, VALVE COVERS, CLEAN OUTS, VAULTS, BOXES, AND GRATES, EXISTING AND PROPOSED, TO "AS-CONSTRUCTED" FINISHED GRADE.
10. IF GRADE ADJUSTMENTS ARE REQUIRED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER TO
INVESTIGATE SUCH ADJUSTMENTS.
11. ALL WASTE MATERIAL NOT UTILIZED ON SITE SHALL BE HAULED TO AN APPROVED LOCATION.
12. ANY EXCAVATED MATERIAL "WASTED" ON SITE SHALL BE PROTECTED BY APPROPRIATE EROSION
CONTROL BMPS. THE OWNER AND ENGINEER SHALL APPROVE THE "WASTE" LOCATION PRIOR TO
PLACEMENT OF MATERIAL BY THE CONTRACTOR.
SS
SS
SS
SS
SS
SS
SSSSSSSSSS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SSSS
SS
SS
SS
W W W
TOTAL SITE AREA = 10.25 ACRES
TOTAL AREA OF DISTURBANCE = 0.41 ACRES
(Label)
(Label) 20 20 40 60 FEET
SCALE: 1" = 20'
24 HOUR CONTACT
RYAN DAVIS
678-733-1618
HB2025-21
PR
O
PO
SE
D S
H O
O
TI
N G
R
AN
G E
P R
O
JE
C T
FO
R
PROJECT NUMBER
REVISIONS
E . 4
TH
A
VE
R
O M
E, G
A
S H
EE
T
TI
TL
E
SHEET NUMBER
FL
O
YD
C
O U
N
TY
B O
AR
D
O F
CO
M
M
IS
SI
O
N
ER
S
P.
O
. B O
X
A R
M U
CH
EE
, G A
-5
-5
R
YA
N
R
W H
IG
G
IN
S.
N
ET
P
O
LI
CE
P
LA
ZA
R O
M E, G A
ER
O
SI
O
CO
TR
O
L
PL
AN
24 HOUR CONTACT
RYAN DAVIS
678-733-1618
HB2025-21
PR
O
PO
SE
D S
H O
O
TI
N G
R
AN
G E
P R
O
JE
C T
FO
R
PROJECT NUMBER
REVISIONS
E . 4
TH
A
VE
R
O M
E, G
A
S H
EE
T
TI
TL
E
SHEET NUMBER
FL
O
YD
C
O U
N
TY
B O
AR
D
O F
CO
M
M
IS
SI
O
N
ER
S
P.
O
. B O
X
A R
M U
CH
EE
, G A
-5
-5
R
YA
N
R
W H
IG
G
IN
S.
N
ET
P
O
LI
CE
P
LA
ZA
R O
M E, G A
EROSION CONTROL NOTES
THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE INSTALLATION OF EROSION AND
SEDIMENT CONTROL MEASURES AND PRACTICES PRIOR TO LAND DISTURBING ACTIVITIES.
EROSION CONTROL MEASURES WILL BE MAINTAINED AT ALL TIMES. IF FULL IMPLEMENTATION OF THE APPROVED PLAN DOES NOT PROVIDE FOR EFFECTIVE EROSION CONTROL, ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE IMPLEMENTED TO CONTROL OR TREAT THE SEDIMENT SOURCE.
ANY DISTURBED AREA LEFT EXPOSED FOR A PERIOD GREATER THAN 14 DAYS SHALL BE STABILIZED WITH
MULCH OR TEMPORARY SEEDING.
THE APPLICABLE PORTION OF THE PRIMARY PERMITTEES ES&PC PLAN IS TO BE PROVIDED TO EACH SECONDARY PERMITTEE PRIOR TO SECONDARY CONDUCTING ANY CONSTRUCTION ACTIVITY AND THAT EACH SECONDARY SHALL SIGN THE PLAN OR PORTION OF THE PLAN APPLICABLE TO THEIR SITE. LIST THE
NAMES AND ADDRESSES OF ALL SECONDARY PERMITTEES.
EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSPECTED AT LEAST WEEKLY, AFTER EACH RAIN, AND REPAIRED AS NECESSARY.
ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSTALLED IF DETERMINED
NECESSARY BY ON-SITE INSPECTION.
ALL SILT FENCES MUST MEET THE REQUIREMENTS OF SECTION 171-TEMPORARY SILT FENCE FOR THE
DEPARTMENT OF TRANSPORTATION, QUALIFIED PRODUCTS LIST #36.
SILT FENCES SHALL NOT BE PLACED IN STREAM BUFFER OR FLOODPLAINS, UNLESS UTILIZED FOR THE CONSTRUCTION OF AN EXEMPT ACTIVITY (I.E. ROADWAY DRAINAGE STRUCTURES, SEWER/WATER CROSSINGS, OR DRAINAGE STRUCTURES) PER THE APPROVED PLANS. FOR SUCH DISTURBANCES WITHIN THE BUFFER, THE AREA SHALL BE IMMEDIATELY STABILIZED USING EROSION CONTROL MATTING AND/OR
BLANKETS ONCE THE ACTIVITY IS COMPLETE.
SEDIMENT STORAGE VOLUME (67 CY/ACRE) MUST BE INSTALLED PRIOR TO ANY OTHER LAND DISTURBANCE
ACTIVITY AND IN PLACE UNTIL FINAL STABILIZATION OCCURS.
FOR EACH SITE ON WHICH LAND DISTURBING ACTIVITY OCCURS, EACH ENTITY OR PERSON ACTING AS EITHER A PRIMARY, SECONDARY, OR TERTIARY PERMITTEE, AS DEFINED IN THE STATE GENERAL PERMIT, SHALL HAVE AS A MINIMUM ONE PERSON WHO IS IN RESPONSIBLE CHARGE OF EROSION AND
SEDIMENTATION CONTROL ACTIVITIES ON BEHALF OF SAID ENTITY OR PERSON AND MEETS THE APPLICABLE (LEVEL 1A) EDUCATION OR TRAINING CERTIFICATION REQUIREMENTS (O.C.G.A. 12-7-19(A)(2)).
ALL TEMPORARY AND PERMANENT SEEDING MUST BE PERFORMED AT THE APPROPRIATE SEASON. IN SUCH INSTANCES WHERE THE ESTABLISHMENT OF VEGETATION IS INOPPORTUNE DUE TO SEASON OR DROUGHT, DISTURBED AREAS SHALL BE TEMPORARILY STABILIZED USING 2”-4” OF MULCH (DS1).
ADDITIONAL PLANTINGS WILL BE NECESSARY IF A SUFFICIENT STAND OF GRASS FAILS TO GROW.
A COPY OF THE APPROVED LAND DISTURBANCE PLAN AND PERMIT SHALL BE PRESENT ON THE SITE AT ALL
TIMES.
PRIOR TO COMMENCING LAND DISTURBANCE ACTIVITY, THE LIMITS OF LAND DISTURBANCE AND ALL STREAM BUFFERS SHALL BE CLEARLY AND ACCURATELY DEMARCATED WITH STAKES, RIBBONS, OR OTHER APPROPRIATE MEANS. THE LOCATION AND EXTENT OF ALL AUTHORIZED LAND DISTURBANCE ACTIVITY SHALL BE DEMARCATED FOR THE DURATION OF THE CONSTRUCTION ACTIVITY. NO LAND DISTURBANCE
SHALL OCCUR OUTSIDE THE APPROVED LIMITS INDICATED ON THE APPROVED PLANS.
PRIOR TO ANY OTHER CONSTRUCTION, A STABILIZED CONSTRUCTION ENTRANCE SHALL BE CONSTRUCTED
AT EACH POINT OF ENTRY TO OR EXIT FROM THE SITE OR ONTO ANY PUBLIC ROADWAY.
THE FOLLOWING INITIAL EROSION CONTROL MEASURES SHALL BE IMPLEMENTED PRIOR TO ANY OTHER
CONSTRUCTION ACTIVITY.
THE CONSTRUCTION EXIT, CONSISTING OF A MINIMUM PAD SIZE OF 20 FEET BY 50 FEET WITH A MINIMUM OF 6” THICK STONE, SHALL BE PLACED AS SHOWN ON THE PLAN. THE STONE SIZE SHOULD CONSIST OF COURSE AGGREGATE BETWEEN 1-1/2” & 3-1/2” IN DIAMETER AND OVERLAID ON A GEOTEXTILE UNDERLINER.
THE GEOTEXTILE UNDERLINER SHALL MEET THE REQUIREMENTS OF AASHTO M288-96, SECTION 7.3
SEPARATION REQUIREMENTS.
IMMEDIATELY AFTER THE ESTABLISHMENT OF CONSTRUCTION ENTRANCE/EXITS, ALL PERIMETER EROSION CONTROL AND TEMPORARY SEDIMENT BASINS SHALL BE INSTALLED AS SHOWN ON THE INITIAL PHASE
EROSION CONTROL PLAN.
SILT FENCE SHOULD BE INSTALLED AT THE PERIMETER OF THE DISTURBED AREA AS SHOWN ON THE PLAN.
THE SILT FENCE SHOULD BE PLACED IN ACCORDANCE WITH THE MANUAL FOR EROSION CONTROL IN GEORGIA, TABLE 6-27.1. THE SILT FENCE SHOULD BE KEPT ERECT AT ALL TIMES AND REPAIRED WHEN REQUESTED BY THE SITE INSPECTOR OR THE PROJECT DESIGN PROFESSIONAL OF RECORD. SILT SHOULD BE REMOVED WHEN ACCUMULATION REACHES ½ HEIGHT OF THE BARRIER. THE PERIMETER SILT FENCE SHOULD BE INSPECTED DAILY FOR ANY FAILURES. ANY FAILURES OF SAID FENCING SHOULD BE REPAIRED
IMMEDIATELY.
STONE CHECK DAMS SHALL BE INSTALLED IN AREAS OF CONCENTRATED FLOWS AS SHOWN ON THE PLAN.
TREE PROTECTION FENCING SHOULD BE INSTALLED PRIOR TO THE START OF ANY LAND DISTURBANCE ACTIVITY AND MAINTAINED UNTIL FINAL LANDSCAPE IS INSTALLED. THE TREE PROTECTION FENCING SHOULD BE INSPECTED DAILY. ANY FAILURES OF SAID FENCING SHOULD BE REPAIRED IMMEDIATELY.
ADDITIONAL SILT BARRIERS MUST BE PLACED AS SHOWN ON THE PLAN AS ACCESS IS OBTAINED DURING CLEARING. NO GRADING SHALL TAKE PLACE UNTIL SILT BARRIER INSTALLATION AND SEDIMENT PONDS ARE
CONSTRUCTED AS SHOWN ON THE CLEARING PHASE EROSION CONTROL PLAN.
SEDIMENT AND EROSION CONTROL MEASURES SHOULD BE CHECKED AFTER EACH RAIN EVENT. EACH DEVICE IS TO BE MAINTAINED OR REPLACED IF SEDIMENT ACCUMULATION HAS REACHED ONE HALF THE
CAPACITY OF THE DEVICE.
THE CONSTRUCTION EXIT SHALL BE MAINTAINED IN A CONDITION, WHICH WILL PREVENT TRACKING OR FLOW OF MUD ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH 1-3” OF STONE, AS CONDITIONS DEMAND. ALL MATERIALS SPILLED, DROPPED, WASHED, OR TRACKED FROM
VEHICLE ON TO PUBLIC ROADWAY OR INTO STORM DRAIN MUST BE REMOVED IMMEDIATELY.
CONTRACTOR SHALL INSPECT EROSION CONTROL MEASURES AT THE END OF EACH WORKING DAY TO
ENSURE MEASURES ARE FUNCTIONING PROPERLY.
FAILURE TO INSTALL, OPERATE, OR MAINTAIN ALL EROSION CONTROL MEASURES WILL RESULT IN ALL CONSTRUCTION BEING STOPPED ON THE JOB UNTIL SUCH MEASURES ARE CORRECTED BACK TO THE
APPROVED EROSION CONTROL PLANS.
THE SITE CONTRACTOR WILL BE RESPONSIBLE FOR MAINTENANCE OF ALL EROSION CONTROL MEASURES INCLUDING REPLACING OR REPAIRING ANY DAMAGED DEVICES DUE TO ANY CONSTRUCTION ACTIVITY BY
OTHERS.
EARTHWORK OPERATIONS IN THE VICINITY OF STREAM BUFFERS SHALL BE CAREFULLY CONTROLLED TO
AVOID DUMPING OR SLOUGHING INTO THE BUFFER AREAS.
SEDIMENT SHALL NOT BE WASHED INTO INLETS. IT SHALL BE REMOVED FROM THE SEDIMENT TRAPS AND
DISPOSED OF AND STABILIZED SO THAT IT WILL NOT ENTER THE INLETS AGAIN.
EROSION CONTROL DEVICES SHALL BE INSTALLED IMMEDIATELY AFTER GROUND DISTURBANCE OCCURS.
THE LOCATION OF SOME OF THE EROSION CONTROL DEVICES MAY HAVE TO BE ALTERED FROM THAT SHOWN ON THE APPROVED PLANS IF DRAINAGE PATTERNS DURING THE CONSTRUCTION ARE DIFFERENT FROM THE PROPOSED DRAINAGE PATTERNS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ACCOMPLISH
EROSION CONTROL FOR ALL DRAINAGE PATTERNS CREATED AT VARIOUS STAGES DURING
CONSTRUCTION. ANY DIFFICULTY IN CONTROLLING EROSION DURING ANY PHASE OF CONSTRUCTION
SHALL BE REPORTED TO THE DESIGN PROFESSIONAL IMMEDIATELY.
THE CONTRACTOR SHALL FURNISH AND MAINTAIN ALL NECESSARY BARRICADES WHILE ROADWAY
FRONTAGE IMPROVEMENTS ARE BEING MADE.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ESTABLISHING BARRIERS AT THE TOE OF SLOPES UNDER CONSTRUCTION. THESE BARRIERS SHALL BE AS SHOWN IN THE PLANS. THESE BARRIERS MAY BE RELOCATED AND REUSED AFTER PERMANENT SLOPE STABILIZATION BECOMES FULLY ESTABLISHED. AS THEY ARE RELOCATED, ANY DEFECTIVE MATERIALS IN THE BARRIER SHALL BE REPLACED. IN ADDITION, ALL DEBRIS AND SILT AT THE PREVIOUS LOCATION SHALL BE REMOVED.
CUT AND FILL SLOPES ARE NOT TO EXCEED “2H:1V”.
INLET SEDIMENT PROTECTION MEASURES SHALL BE INSTALLED ON ALL STORM STRUCTURES AS THEY ARE
CONSTRUCTED. SEE PLAN VIEW FOR SPECIFIC TYPE AND SEPARATE DETAILS FOR ADDITIONAL
INFORMATION ON TYPE OF INLET PROTECTION SPECIFIED.
STORM DRAIN OUTLET PROTECTION SHALL BE PLACED AT ALL OUTLET HEADWALLS AS SOON AS THE
HEADWALL IS CONSTRUCTED. SEE DETAILS FOR ADDITIONAL INFORMATION.
ER
O
SI
O
N C
O N
TR
O
L N
O
TE
S
D
ET
AI
LS
SCHEDULE: 6/01/26-6/01/27
CRUSHED STONE CONSTRUCTION EXIT
EXIT DIAGRAM
TOTAL SITE AREA = 10.25 ACRES
TOTAL AREA OF DISTURBANCE = 0.41 ACRES
(9) DESCRIPTION OF CONSTRUCTION ACTIVITIES & EXISTING CONDITIONS:
THE PROJECT WILL CONSIST OF THE CONSTRUCTION OF A 4,800 S.F. METAL BUILDING, 324 S.F. BUILDING ADDITION AND AN ASPHALT PARKING LOT , THE EXISTING SITE WAS PREVIOUSLY DEVELOPED AND HAS AN EXISTING 1,330 S.F. BUILDING WHICH WILL REMAIN IN PLACE AND A GRAVEL PARKING AREA. THE REMAINDER OF THE SITE IS MOSTLY GRASSED. THE SITE AREA CONSIST OF
0.93 ACRES AND IS ZONED COMMERCIAL. THE SITE IS LOCATED ON LAND LOT 1810, 3RD DISTRICT IN FLOYD COUNTY GA. THE SITE IS BOUND TO THE NORTH BY AN ABANDONED RAILROAD, A MOBILE HOME PARK TO THE EAST, TO THE WEST UNDEVELOPED LAND, AND CAVE SPRING ROAD TO THE SOUTH. AN UNDERGROUND DETENTION POND WILL BE CONSTRUCTED IN THE WESTERN PORTION OF THE SITE. THE IMPROVEMENTS MADE WILL DRAIN TO THE PROPOSED DETENTION FACILITY. THE POLLUTANT SOURCES WILL BE SILT, SEDIMENT, AND OTHER SUSPENDED SOLIDS DURING THE CONSTRUCTION PROCESS AS WELL AS RUNOFF FROM THE IMPERVIOUS
AREAS AFTER CONSTRUCTION.
(11) RECEIVING WATERS & SENSITIVE AREAS.
(12) THE FOLLOWING STATEMENT AND THE SIGNATURE OF THE DESIGN PROFESSIONAL MUST BE SHOWN ON THE ES&PC PLAN OR UNDER ES&PCNOTES. "I CERTIFY UNDER PENALTY OF LAW THAT THIS PLAN WAS PREPARED AFTER A SITE VISIT TO THE LOCATIONS DESCRIBED HEREIN BY MYSELFOR MY AUTHORIZED
AGENT, UNDER MY SUPERVISION."
SIGNATURE DATE
HB2025-21
PR
O
PO
SE
D S
H O
O
TI
N G
R
AN
G E
P R
O
JE
C T
FO
R
PROJECT NUMBER
REVISIONS
E . 4
TH
A
VE
R
O M
E, G
A
S H
EE
T
TI
TL
E
SHEET NUMBER
FL
O
YD
C
O U
N
TY
B O
AR
D
O F
CO
M
M
IS
SI
O
N
ER
S
P.
O
. B O
X
A R
M U
CH
EE
, G A
-5
-5
R
YA
N
R
W H
IG
G
IN
S.
N
ET
P
O
LI
CE
P
LA
ZA
R O
M E, G A
ER
O
SI
O
VE
G
ET
AT
IO
PL
AN
24 HOUR CONTACT
RYAN DAVIS
678-733-1618
1'-2"
1'-0"
6"
9"
1'-2'
1'-0" 15"
15'-20'
5'
UPSTREAM TERMINAL
TRANSVERSE CHECK SLOT
STEP 1 : CUT TERMINAL SLOT
STEP 2 : SNUG MAT INTO
SLOT
STEP 3 : A. STAKE MAT INTO SLOT.
B. USE 1"x3" PRESSURE-TREATED BOARD TO BRACE
MAT AGAINST VERTICAL CUT.
C. BACKFILL AND COMPACT.
STEP 4 : A. REVERSE MAT ROLL DIRECTION TO OVERLAY CHECK SLOT.
B. STAKE MAT TO ANCHOR TERMINAL.
STEP 1 : CUT CHECK SLOT.
TEMPORARY STAKE MAT
UNDER MODERATE TENSION.
STEP 2 : WORK UPSTREAM
ACROSS, CHECK SLOT
LAP BACK 18".
STEP 3 : TUCK MAT LAP INTO
SLOT & STAKE.
STEP 1 : CUT TERMINAL SLOT.
STEP 2 : STAKE MAT INTO SLOT.
STEP 3 : BACKFILL
TERMINAL SLOT.
SEE NOTE 3-8
5'
3' OVERLAP
5'
3"
ROLL NO. 1
ROLL NO. 3
ROLL NO. 2
SEQUENTIAL ROLL RUN OUT
IN CHANNELS
STAKE
38"
9"
8"
TEMPORARY BLANKETS
PERMANENT MATTING
DISTURBED AREA
STABILIZATION WITH MULCHING
TEMPORARY METHODS
MULCHES.
PERMANENT METHODS
PERMANENT VEGETATION
APPROPRIATE SOD VARIETIES FOR MOUNTAIN;
BLUE RIDGE; AND RIDGES AND VALLEYS.
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SSSSSSSSSS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SSSSSSSS
SS
SS
SS
SS
SS
SS
SS
SSSSSSSSSSSSSSSS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
24 HOUR CONTACT
RYAN DAVIS
678-733-1618
HB2025-21
PR
O
PO
SE
D S
H O
O
TI
N G
R
AN
G E
P R
O
JE
C T
FO
R
PROJECT NUMBER
REVISIONS
E . 4
TH
A
VE
R
O M
E, G
A
S H
EE
T
TI
TL
E
SHEET NUMBER
FL
O
YD
C
O U
N
TY
B O
AR
D
O F
CO
M
M
IS
SI
O
N
ER
S
P.
O
. B O
X
A R
M U
CH
EE
, G A
-5
-5
R
YA
N
R
W H
IG
G
IN
S.
N
ET
P
O
LI
CE
P
LA
ZA
R O
M E, G A
40 40 80 120 FEET
SCALE: 1" = 40'
24 HOUR CONTACT
RYAN DAVIS
678-733-1618
HB2025-21
PR
O
PO
SE
D S
H O
O
TI
N G
R
AN
G E
P R
O
JE
C T
FO
R
PROJECT NUMBER
REVISIONS
E . 4
TH
A
VE
R
O M
E, G
A
S H
EE
T
TI
TL
E
SHEET NUMBER
FL
O
YD
C
O U
N
TY
B O
AR
D
O F
CO
M
M
IS
SI
O
N
ER
S
P.
O
. B O
X
A R
M U
CH
EE
, G A
-5
-5
R
YA
N
R
W H
IG
G
IN
S.
N
ET
P
O
LI
CE
P
LA
ZA
R O
M E, G A
40 40 80 120 FEET
SCALE: 1" = 40'
Envelope Compliance Certificate
Building Area Floor Area 1-Office : Nonresidential 1828 2-Warehouse : Nonresidential 3518
Assembly Cavity R-Value
Cont.
R-Value
Proposed U-Factor
Budget U- Factor(a)
Gross Area or
Perimeter
121 --- 5.0 0.580 0.540
220 --- 5.0 0.580 0.540
1828 --- 30.0 0.032 0.032 3518 --- 30.0 0.032 0.032
586 --- 5.0 0.128 0.104
98 13.0 5.0 0.059 0.064
1002 --- 5.0 0.128 0.104
21 --- --- 0.300 0.610 324 13.0 5.0 0.059 0.064 153 --- 9.0 0.079 0.104
576 13.0 5.0 0.059 0.064 30 --- --- 0.290 0.380
30 --- --- 0.290 0.380
68 --- --- 0.290 0.770
Assembly Cavity R-Value
Cont.
R-Value
Proposed U-Factor
Budget U- Factor(a)
Gross Area or
Perimeter
846 --- 5.0 0.128 0.104
158 13.0 5.0 0.059 0.064 35 --- --- 0.300 0.610 24 --- --- 0.300 0.610
480 13.0 5.0 0.059 0.064 21 --- --- 0.300 0.610
(a) (b) (c)
Elizabeth Dunay 4/21/26
6-5-2026
PLUMBING LEGENDPLUMBING FIXTURE SCHEDULE
CIRCULATING PUMP SCHEDULE
PIPING LABEL COLOR GUIDE SIZE OF LEGEND LETTERS
ELECTRIC WATER HEATER SCHEDULE
STATUS: CD
DATE: 5/29/2026
PROJECT # 2534
REVISIONS
STATUS: CD
DATE: 5/29/2026
VV
SANITARY PIPING PLAN
SCALE: 3/16" = 1'-0"
PLAN
NORTH
STATUS: CD
DATE: 5/29/2026
PROJECT # 2534
REVISIONS
WATER PIPING PLAN
SCALE: 3/16" = 1'-0"
PLAN
NORTH
STATUS: CD
DATE: 5/29/2026
HVAC LEGEND
HVAC ABBREVIATIONS
STATUS: CD
DATE: 5/29/2026
AIR DISTRIBUTION EQUIPMENT SCHEDULE
EXHAUST FAN SCHEDULESPLIT SYSTEM HEAT PUMP UNIT SCHEDULE
MINI-SPLIT HEAT PUMP UNIT SCHEDULE
ELECTRIC UNIT HEATER SCHEDULE
WALL LOUVER SCHEDULE
GAS HEAT MAKEUP AIR UNIT SCHEDULE
FILTER SCHEDULE
STATUS: CD
DATE: 5/29/2026
STATUS: CD
DATE: 5/29/2026
HVAC PLAN
SCALE: 3/16" = 1'-0"
PLAN
NORTH
STATUS: CD
DATE: 5/29/2026
STATUS: CD
DATE: 5/29/2026
STATUS: CD
DATE: 5/29/2026
GAS PIPE HANGER SPACING
STATUS: CD
DATE: 5/29/2026
T
X
T
TVTV
CCTVCCTV
ELECTRICAL SPECIFICATIONS:
WPWP
IG
J JJ J
LIGHTING CONTROL GENERAL NOTES:
ELECTRICAL GENERAL NOTES:
GFCI NOTES:
STATUS: SD
DATE: 3/4/2026
PROJECT # 2534
REVISIONS
E.1.0
ELECTRICAL NOTES,
LEGEND, & SPECS
FLEX WITH GROUND
DO NOT SECURE TO
CEILING
FIXTURE SUPPORT CHAINS
PER SPECS INSTALLED ON
DIAGONAL CORNERS
T-BAR MOUNTING CLIP
(TYPICAL FOR 4)
JUMPER
OR UNION
VALVE, METER
UL APPROVED
GROUND CLAMP
SIDE
SUPPLY
WATER SERVICE
STEEL
CAD WELD
BUILDING
STRUCTURAL
SIZE PER NEC 250.102
EQUIPMENT BONDING JUMPER
(WHERE AVAILABLE)
REBAR IN BUILDING FOOTING
20'-0" MIN. OF 1/2"
(MIN. 6' APART)
5/8" x 10'
GROUND ROD
CAD WELD
SIZE PER NEC 250.66
#6 CU
GROUND BUS
TO PHONE BACKBOARDS,
LIGHTNING PROTECTION
NEUTRAL
SERVICE GROUNDING AT MAIN
MAIN BONDING JUMPER
SIZE PER NEC 250.28
12" TIE AREA MIN.
TO MAIN SERVICE GROUND BAR.
PROVIDE #4 CU SOLID GROUND WIRE AT
POINT BEFORE WIRE ENTERS SLEEVE.
MAKE EXOTHERMIC WELDS AT ALL
SPLICES.
5"Ø NON-METALLIC PROTECTIVE SLEEVE TO
4" ABOVE AND BELOW WHERE WIRE
ENTERS SLAB.
20' MIN OF BARE (NON-EPOXY COATED)
ELECTRODE OR TIE TO 20' OF
ELECTRICALLY CONDUCTIVE COATED
STEEL REINFORCING BAR (IF EPOXY REBAR
IS USED) ELECTRODE/REBAR SHALL BE
LOCATED NEAR THE BOTTOM OF THE
CONCRETE FOUNDATION AND ENCASED
WITH A MINIMUM OF 2" CONCRETE. INSTALL
PER NEC 250-50(C).
CONCRETE FOUNDATION IN CONTACT
DIRECTLY WITH THE EARTH.NO
NON-METALLIC VAPOR BARRIER ALLOWED.
MINIMUM OF THREE SETS OF WRAP TO
BOND TURN-UP TO MINIMUM 20' OF BARE
REBAR.
LINK
CAD WELD
#4 CU
SIZE PER NEC 250.66
METER BASE
6'- 0"
6" STEEL CHANNEL
PAINT BLACK
1-1/2" RGS CONDUIT
2'- 0"
TO TRANSFORMER
CONCRETE FOOTING
EQUIPMENT
GROUND
CIRCUIT
#1
TIME CLOCK C1
NC
NO
COM
R1-19
LIGHTING
CIRCUIT
#2
NC
NO
COM
CIRCUIT
#3
NC
NO
COM
CIRCUIT
#4
NC
NO
COM
CONTROL
120 VAC
R1-24
EQUIPMENT
GROUND
CIRCUIT
#1
TIME CLOCK C2
NC
NO
COM
CIRCUIT
#2
NC
NO
COM
CIRCUIT
#3
NC
NO
COM
CIRCUIT
#4
NC
NO
COM
R1-22
EXTERIOR
LIGHTING
R1-21
LIGHTING
CONTROL
120 VAC
R1-26
SPARE
R1-23
LIGHTING
R1-25
LIGHTING
DATE: 3/4/2026
PROJECT # 2534
REVISIONS
E.2.0
ELECTRICAL DETAILS
& SCHEDULES
ELECTRICAL RISER DIAGRAM
NTS
NEUTRAL/GROUNDING DETAIL
NTS
CONCRETE ENCASED ELECTRODE DETAIL
NTS
METERBASE STANCHION DETAIL
NTS
TROFFER HANGING DETAIL
NTS
TIME CLOCK DETAILS
NTS
UTILITY TARGET
STORAGE
ARMORY
CL
LOBBY
LECTURE HALL
SHOOTING RANGE
JAN.
102 103
104 105 106
CEILING PLAN KEY NOTES:
CEILING PLAN GENERAL NOTES:
FLOOR PLAN KEY NOTES:
FLOOR PLAN GENERAL NOTES:
J
J
T
DATE: 3/4/2026
PROJECT # 2534
REVISIONS
E.3.0
ELECTRICAL
PLAN
ELECTRICAL CEILING PLAN
1/8" = 1'-0"
ELECTRICAL FLOOR PLAN
1/8" = 1'-0"