Seismic Certification.docx

DOCX document 37 KB Posted

Attached to
JONESBORO, AR SYSTEMS SUPPORT CENTER RELOCATION
Solicitation number
697DCM-24-L-00048b
Issued by

About this file

This document is a Life Safety Compliance/Seismic Certification form related to a federal contract opportunity for Jonesboro, AR.

The form requires a licensed structural engineer to certify whether the building is a new construction, undergoing major renovations, or an existing building not undergoing renovations. For new/renovated buildings, the engineer must certify compliance with the appropriate seismic building code. For existing buildings, the engineer must certify compliance with seismic safety standards RP-8 or the ASCE 31-03 'Life Safety' standard.

The related federal contract opportunity is for 3,000-3,500 square feet of flex/technical space within 10 miles of the Jonesboro, AR municipal airport, including 1,221 ABOA SF of office space, 1,825 ABOA SF of technical space, and a 1,900 SF fenced exterior storage area. The solicitation is being issued by the Department of Transportation Federal Aviation Administration.

View the file

Other files

File Type Posted
Lessors Annual Cost Statement.docx DOCX document
Proposal To Lease Space.docx DOCX document
Leased Space Access.docx DOCX document
697DCM-24-L-00048_SFO_LEASE 5.15.24.docx DOCX document
697DCM-24-L-00048_SFO 5.15.24.docx DOCX document
Space Safety Environmental Checklist.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OMB CONTROL NO. 2120-0595

Department of Transportation Federal Aviation Administration Life Safety Compliance/Seismic Certification In response to Announcement/ Lease Contract #:

697DCM-24-L-00048

Jonesboro, AR

Date: MM/DD/YYYY

Paperwork Reduction Act Burden Statement A federal agency may not conduct or sponsor, and a person is not required to respond to, nor shall a person be subject to a penalty for failure to comply with a collection of information subject to the requirements of the Paperwork Reduction Act unless that collection of information displays a currently valid OMB Control Number. The OMB Control Number for this information collection is 2120-0595. Public reporting for this collection of information is estimated to be approximately 30 minutes per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information.

Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to: Information Collection Clearance Officer, Federal Aviation Administration, 10101 Hillwood Parkway, Fort Worth, TX 76177-1524

Instructions: Building owner must have a licensed structural engineer evaluate the building and fill out the below certification.

Date: ____________ Building Address: _______________________________________________________________ City, State, and Zip code: _________________________________________________________ I certify that the building above (check one):

☐ is a New Building or Major Renovations are planned to the existing building where renovation costs exceed 50% of replacement cost of building and the building meets appropriate seismic provisions of _____________________________ (IBC or local seismic building code, if more stringent than IBC) edition of ___________________. (Attach documentation confirming compliance).

The below apply only to Existing Buildings not undergoing Major Renovations:

☐was designed, built and maintained to the requirements of seismic standards RP-8 as specified in Section 2.2 of Standards of Seismic Safety for Existing Federally Owned or Leased Buildings and Commentary issued by the Interagency Committee on Seismic Safety in Construction as ICSSC RP-8, Seismic Standards for Existing Federally Owned and Leased Buildings, Dec 2011. (Attach documentation confirming compliance.)

☐meets the minimum acceptable performance seismic standard of ‘Life Safety’ using the American Society for Civil Engineers (ASCE) 31-03, Seismic Evaluation of Existing Buildings. (Attach documentation confirming compliance.)

☐is a benchmark building according to RP-8 Section 1.3.1. (Attach documentation confirming compliance.)

Structural Engineer completing certificate:

(Print name)

(Signature)

License No. _____________________________________ Field of Practice _________________________________ SEAL: Expiration Date ________________________

Federal Aviation Administration Page 1 of 2 Life Safety Compliance/Seismic Certification, 10/2022 FAA Form 4400-90