S02 - Attachment 01 - Drawings Replace Plumbing (68 pages).pdf
PDF 15 MB Posted
- Attached to
- J045--Replace Plumbing Systems in Bldg. 64 Federal contract opportunity
- Solicitation number
- 36C24822R0194
About this file
This document outlines a federal solicitation to replace plumbing systems in Building 64 at the Lake City Veterans Affairs Medical Center in Lake City, Florida. The solicitation seeks to remove and replace the existing overhead horizontal sanitary mains and branches in the basement level ceiling space to address problems caused by the poor condition of the existing piping. Work must be completed according to the provided specifications and construction drawings and minimize downtime. A mandatory site visit is scheduled for October 18, 2022 at 10:00 AM EST where attendees will park in the visitors lot and meet in Conference Room B11-19 of Building 19. The solicitation is issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24822R0194 0001.docx | DOCX document | |
| S02 - Attachment 09 - Past Performance Survey (3 pages).docx | DOCX document | |
| S02 - Attachment 07 - Experience Modification Rate (EMR) (1 page).docx | DOCX document | |
| S02 - Attachment 11 - Subcontractor Past Performance Consent Form (1 page).docx | DOCX document | |
| S02 - Attachment 10 - Letter of Commitment Key Subcontractors (1 page).pdf | ||
| S02 - Attachment 03 - VAAR 852.219-77 LOS Certification (2 pages).docx | DOCX document | |
| 36C24822R0194 (Replace Plumbing).docx | DOCX document | |
| S02 - Attachment 08 - Past Performance Questionnaire (3 pages).docx | DOCX document | |
| S02 - Attachment 06 - Price Matrix (1 page).xlsx | XLSX spreadsheet | |
| S02 - Attachment 05 Wage Determination.pdf | ||
| S02 - Attachment 04 - VHA Supplemental Contract Requirements for Combatting COVID-19 (2 pages).docx | DOCX document | |
| S02 - Attachment 02 - Specifications Replace Plumbing (360 pages).pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VA PROJECT NO. 573A4-18-600
REPLACE PLUMBING SYSTEMS IN BUILDING 64
LAKE CITY
VETERANS AFFAIRS MEDICAL CENTER
PROJECT LOCATION MAP
VICINITY MAP
PROJECT LOCATION
VICINITY MAP
LAKE CITY, FL
NOT TO SCALE
VAMC
PROJECT
LOCATION
247 N www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr. Suite H, Melbourne, Florida 32904
PH: 321.345.9026
LAKE CITY VA MEDICAL CENTER
619 S MARION AVE, LAKE CITY, FL 32025
DESIGNED FOR: DESIGNED BY:
K
LE DA
IV
S
P R
O F
ESS ION A L ENG
I N
E E
R
L I CENSE
F
LO R I D A
STATE OF
No. 84275
Y J.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
C U s e rs \a z g o d a \D o c u m e n ts \0
R e p la c e
P lu m b in g
S y s te m s B ld g
P
R a z g o d a .R
V T
/2
/2
:0
:4
P
M
CS-001
COVER SHEET
REPLACE PLUMBING
SYSTEMS IN BLDG. 64
Lake City, Florida
573A4-18-600
PAUL DRAKE
08/27/2021 KJD JAR
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
KYLE J. DAVIS, P.E.
FL License #84275
INDEX OF DRAWINGS
Sheet
Discipline
Sheet
Number Sheet Name
GENERAL CS-001 COVER SHEET
ARCHITECTURE G101 LIFE SAFETY & PHASING PLANS
ARCHITECTURE G102 LIFE SAFETY & PHASING PLANS
ARCHITECTURE G103 LIFE SAFETY & PHASING PLANS
ARCHITECTURE G104 LIFE SAFETY & PHASING PLANS
ARCHITECTURE G105 LIFE SAFETY & PHASING PLANS
ARCHITECTURE G106 LIFE SAFETY & PHASING PLANS
ARCHITECTURE G107 LIFE SAFETY & PHASING PLANS
ARCHITECTURE G108 LIFE SAFETY & PHASING PLANS
ARCHITECTURE G109 LIFE SAFETY & PHASING PLANS
ARCHITECTURE G110 LIFE SAFETY & PHASING PLANS
ARCHITECTURE G111 LIFE SAFETY & PHASING PLANS
PLUMBING PL-001 PLUMBING LEGENDS, NOTES, SPECIFICATIONS & SYMBOLS
PLUMBING PL-101 BLDG. 64 UNIT A SANITARY - OVERALL DEMO
PLUMBING PL-102 BLDG. 64 UNIT B SANITARY - OVERALL DEMO
PLUMBING PL-201 BLDG. 64 UNIT A SANITARY - PHASE 1
PLUMBING PL-202 BLDG. 64 UNIT A SANITARY - PHASE 1 PHOTOS
PLUMBING PL-203 BLDG. 64 UNIT A SANITARY - PHASE 2
PLUMBING PL-204 BLDG. 64 UNIT A SANITARY - PHASE 2 PHOTOS
PLUMBING PL-205 BLDG. 64 UNIT A SANITARY - PHASE 3
PLUMBING PL-206 BLDG. 64 UNIT A SANITARY - PHASE 3 PHOTOS
PLUMBING PL-207 BLDG. 64 UNIT A SANITARY - PHASE 4
PLUMBING PL-208 BLDG. 64 UNIT A SANITARY - PHASE 4 ISOMETRIC
PLUMBING PL-209 BLDG. 64 UNIT A SANITARY - PHASE 4 PHOTOS
PLUMBING PL-210 BLDG. 64 UNIT A SANITARY - PHASE 5
PLUMBING PL-211 BLDG. 64 UNIT A SANITARY - PHASE 5 PHOTOS
PLUMBING PL-212 BLDG. 64 UNIT A SANITARY - PHASE 6
PLUMBING PL-213 BLDG. 64 UNIT A SANITARY - PHASE 6 PHOTOS
PLUMBING PL-214 BLDG. 64 UNIT B SANITARY - PHASE 7
PLUMBING PL-215 BLDG. 64 UNIT B SANITARY - PHASE 7 PHOTOS
PLUMBING PL-216 BLDG. 64 UNIT B SANITARY - PHASE 8
PLUMBING PL-217 BLDG. 64 UNIT B SANITARY - PHASE 8 PHOTOS
PLUMBING PL-218 BLDG. 64 UNIT B SANITARY - PHASE 9
PLUMBING PL-219 BLDG. 64 UNIT B SANITARY - PHASE 9 PHOTOS
PLUMBING PL-220 BLDG. 64 UNIT B SANITARY - PHASE 10
PLUMBING PL-221 BLDG. 64 UNIT B SANITARY - PHASE 10 PHOTOS
PLUMBING PL-222 BLDG. 64 UNIT B SANITARY - PHASE 11
PLUMBING PL-223 BLDG. 64 UNIT B SANITARY - PHASE 11 PHOTOS
PLUMBING PL-224 RISER SCHEDULES
PLUMBING PL-225 RISER SCHEDULES
PLUMBING PL-226 RISER SCHEDULES
PLUMBING PL-227 RISER SCHEDULES
PLUMBING PL-228 RISER SCHEDULES
PLUMBING PL-301 BLDG. 64 - BASEMENT - UNIT A ROOMS AFFECTED BY PHASE
PLUMBING PL-302 BLDG. 64 - FIRST FLOOR - UNIT A ROOMS AFFECTED BY PHASE
PLUMBING PL-303 BLDG. 64 - SECOND FLOOR - UNIT A ROOMS AFFECTED BY PHASE
PLUMBING PL-304 BLDG. 64 - THIRD FLOOR - UNIT A ROOMS AFFECTED BY PHASE
PLUMBING PL-305 BLDG. 64 - FOURTH FLOOR - UNIT A ROOMS AFFECTED BY PHASE
PLUMBING PL-306 BLDG. 64 - BASEMENT - UNIT B ROOMS AFFECTED BY PHASE
PLUMBING PL-307 BLDG. 64 - SECOND FLOOR - UNIT B ROOMS AFFECTED BY PHASE
PLUMBING PL-308 BLDG. 64 - THIRD FLOOR - UNIT B ROOMS AFFECTED BY PHASE
PLUMBING PL-309 BLDG. 64 - FOURTH FLOOR - UNIT B ROOMS AFFECTED BY PHASE
PLUMBING PL-310 BLDG. 64 UNIT A SANITARY - OVERALL DEMO PHASE 1
PLUMBING PL-311 BLDG. 64 UNIT A SANITARY - OVERALL DEMO PHASE 2
PLUMBING PL-312 BLDG. 64 UNIT A SANITARY - OVERALL DEMO PHASE 3
PLUMBING PL-313 BLDG. 64 UNIT A SANITARY - OVERALL DEMO PHASE 4
PLUMBING PL-314 BLDG. 64 UNIT A SANITARY - OVERALL DEMO PHASE 5
PLUMBING PL-315 BLDG. 64 UNIT A SANITARY - OVERALL DEMO PHASE 6
PLUMBING PL-316 BLDG. 64 UNIT B SANITARY - OVERALL DEMO PHASE 7
PLUMBING PL-317 BLDG. 64 UNIT B SANITARY - OVERALL DEMO PHASE 8
PLUMBING PL-318 BLDG. 64 UNIT B SANITARY - OVERALL DEMO PHASE 9
PLUMBING PL-319 BLDG. 64 UNIT B SANITARY - OVERALL DEMO PHASE 10
PLUMBING PL-320 BLDG. 64 UNIT B SANITARY - OVERALL DEMO PHASE 11
PLUMBING PL-401 PLUMBING DETAILS
PLUMBING PL-501 PLUMBING SCHEDULES
ELECTRICAL E-001 ELECTRICAL LEGEND AND GENERAL NOTES
ELECTRICAL EP-101 BLDG . 64 - BASEMENT - UNIT A ELECTRICAL PLAN
ELECTRICAL EP-102 BLDG . 64 - BASEMENT - UNIT B ELECTRICAL PLAN
Revisions: Date:
AB24
AB03
P-1/64
P-2/64
S-4/64
S-3/64
C B
AB22B
AB21 AB13
AB19
ABO8B
ABO5C
ABO5E
ABO5D
ABO5B
C B
AB28
AB29
AB22D
AB23
AB22C
AB23A
AB21B
AB27
AB22
AB26
AB22A
AB21A
AB21C AB21D
AB18B
AB18C AB18D
AB18A
AB16
AB14
AB15
AB17
AB19A
AB17A
AB12
AB11
AB25ABO5A
ABO5
ABO8A ABO8
ABO6ABO7A
ABO7
ABO4
ABO2
ABO1
ABO9
AB10
ABO6A
ABO9A
AB11A
AB12A
AB12B
C B
CB-4
CB-3
CB-3
C B
AB28
AB29
BB03A
C B
AB28A
C15
C8
C7A
C7
MECH.
RM.
STAIR
STAIR
STAIR
F.A.C.
UTIL.
TUNNEL/AREAWAY
OFC.
LINEN
CHUTE
GAS
STERILE & NON-STERILE
STORAGE
PREP. &
STERILIZATION
SOILED
RECIEVING
DECONTAMINATION
STOR.
TISSUE
STOR.
SPDFEM.
TOIL.
MORT.
REFRIG.
HAC
STORAGE
S.TOIL.
ELEC.
TECH. COMP.
SPEC.
LEAD.
SPEC.
CORRIDOR
LINEN
CHUTE
IRMS
STOR.
EMS
STOR.
EMS.
SUPRINT
DEC.
SUPR.
MECH.
RM.
EMS
STOR.
PATIENT
CLOTHINGROOM
F.A.C.
EL.CL.
SPD
MALETOIL
S V C E L E V
L O B B Y
AUTOPSY
ROOM
MECH
RM.
MECH. EQUIP.
RM.
A/C
SHOP LINEN
FORMS
FIRE ALARM
SYSTEMENG.
STORAGE
EMS
STOR.
CONFERANCE
ROOM
EMS
STOR.
MECH.
ROOM
FORMS
STORAGE
EMS
STOR. SUPR.
OFC.
EMS
STORAGESIGN
SHOP
DISPATCH
EMS
STOR.
CHUTE
MECH.
STOR.
CORRIDOR
CORRIDOR
STEAM
ROOM
STORAGE
MASONRY
SHOP
C O R R
ID
O R
P A S S .E L E V
L O B B Y
C O R R
ID
O R
DISPATCH
CHIEF
SPD CLERICAL
SPD
C O R R
ID
O R
RECIEVING
SPD
CLEAN
STORAGE
SPD STERILE & NON
STERILE
STAIR
SUPR.
0-HR Smoke Partition - NFPA 101 - 8.4
1-HR Smoke Barrier - NFPA 101 - 8.5
1-HR Fire Barrier - NFPA 101 - 8.3
2-HR Fire Barrier - NFPA 101 - 8.3
Means of Egress
Existing Wall to Remain
Proposed Temporary Wall Location - Wall Type T1.0
CODE LEGEND
T1.0
9.21
9.02
9.80
9.45
4 1/4"
STRUCTURE ABOVE
FIN. CEILING
FLOOR SLAB
9.45
CONSTRUCTION SIDE CLEAN SIDE
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
/2
/2
:4
:1
P
M
REPLACE PLUMBING
SYSTEMS IN BLDG. 64
08/27/2021
LIFE SAFETY& PHASING PLANS
G101
NSJR
573A4-18-600
Lake City, Florida
PAUL DRAKE
100% CONSTRUCTION
DOCUMENTS
N Scale: 1/8" = 1'-0"
CODE PLAN - PHASE 1
GENERAL PHASING NOTES
A. Temporary partition to structural deck above. If temporary partition cannot be built to deck due to utilities above the ceiling a fire retardant plastic may be used from the suspended ceiling to the structural deck to seal up construction area and enable a negative air construction zone.
B. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the COR.
C. Coordinate phase completion with requirements as set for by COR to maintain daily operations to near as normal as possible.
D. Coordinate access to all phases of construction, deliveries, and debris removal with the COR. See General Requirements.
E. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. All temporary doors shall be accessible to maintenance personnel to gain access to maintenance rooms inside construction areas. Coordinate final door locations with COR.
F. All existing doors to surrounding a construction phase must be sealed to prevent the passage of smoke. Install plastic zipper walls at all entrances to construction phases.
G. Existing utilities shall remain in operation during construction.
H. Provide and maintain negative air pressure inside construction zone.
I. All marked exits shall be maintained throughout construction. If an exit is required to be blocked temporary signage must be installed to direct to the nearest exit. Coordinate closing of exits with COR.
J. Verify proper fire stopping is installed at penetrations of rated walls.
Scale: 1" = 1'-0"
TEMPORARY PARTITION TYPE
9.02 3 5/8" non-structural metal framing @ 16" o.c.
9.21 5/8" Type X gypsum board.
9.45 Flame-retardant plastic sheeting sealed to create negative air pressure inside work zone.
9.80 Acoustic insulation
NOTES
Revisions Date
P-1/64
P-2/64
S-4/64
S-3/64
C B
AB22B
AB21 AB13
AB19
ABO8B
ABO5C
ABO5E
ABO5D
ABO5B
C B
AB28
AB29
AB22D
AB23
AB22C
AB23A
AB21B
AB27
AB22
AB26
AB22A
AB21A
AB21C AB21D
AB18B
AB18C AB18D
AB18A
AB16
AB14
AB15
AB17
AB19A
AB17A
AB12
AB11
AB25ABO5A
ABO5
ABO8A ABO8
ABO6ABO7A
ABO7
ABO4
ABO2
ABO1
ABO9
AB10
ABO6A
ABO9A
AB11A
AB12A
AB12B
C B
CB-4
CB-3
CB-3
C B
AB28
AB29
BB03A
C B
AB28A
C15
C8
C7A
C7
AB20B
MECH.
RM.
STAIR
STAIR
STAIR
F.A.C.
UTIL.
TUNNEL/AREAWAY
OFC.
LINEN
CHUTE
GAS
STERILE & NON-STERILE
STORAGE
PREP. &
STERILIZATION
SOILED
RECIEVING
DECONTAMINATION
STOR.
TISSUE
STOR.
SPDFEM.
TOIL.
MORT.
REFRIG.
HAC
STORAGE
S.TOIL.
ELEC.
TECH. COMP.
SPEC.
LEAD.
SPEC.
CORRIDOR
LINEN
CHUTE
IRMS
STOR.
EMS
STOR.
EMS.
SUPRINT
DEC.
SUPR.
MECH.
RM.
EMS
STOR.
PATIENT
CLOTHINGROOM
F.A.C.
EL.CL.
SPD
MALETOIL
S V C E L E V
L O B B Y
AUTOPSY
ROOM
MECH
RM.
MECH. EQUIP.
RM.
A/C
SHOP LINEN
FORMS
FIRE ALARM
SYSTEMENG.
STORAGE
EMS
STOR.
CONFERANCE
ROOM
EMS
STOR.
MECH.
ROOM
FORMS
STORAGE
EMS
STOR. SUPR.
OFC.
EMS
STORAGESIGN
SHOP
DISPATCH
EMS
STOR.
CHUTE
MECH.
STOR.
CORRIDOR
CORRIDOR
STEAM
ROOM
STORAGE
MASONRY
SHOP
C O R R
ID
O R
P A S S .E L E V
L O B B Y
C O R R
ID
O R
DISPATCH
CHIEF
SPD CLERICAL
SPD
C O R R
ID
O R
RECIEVING
SPD
CLEAN
STORAGE
SPD STERILE & NON
STERILE
STAIR
RECPT.
EMS.
ASST.CHIEF
SUPR.
0-HR Smoke Partition - NFPA 101 - 8.4
1-HR Smoke Barrier - NFPA 101 - 8.5
1-HR Fire Barrier - NFPA 101 - 8.3
2-HR Fire Barrier - NFPA 101 - 8.3
Means of Egress
Existing Wall to Remain
Proposed Temporary Wall Location - Wall Type T1.0
CODE LEGEND
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
/2
/2
:4
:1
P
M
REPLACE PLUMBING
SYSTEMS IN BLDG. 64
08/27/2021
LIFE SAFETY& PHASING PLANS
G102
NSJR
573A4-18-600
Lake City, Florida
PAUL DRAKE
100% CONSTRUCTION
DOCUMENTS
N Scale: 1/8" = 1'-0"
CODE PLAN - PHASE 2
GENERAL PHASING NOTES
A. Temporary partition to structural deck above. If temporary partition cannot be built to deck due to utilities above the ceiling a fire retardant plastic may be used from the suspended ceiling to the structural deck to seal up construction area and enable a negative air construction zone.
B. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the COR.
C. Coordinate phase completion with requirements as set for by COR to maintain daily operations to near as normal as possible.
D. Coordinate access to all phases of construction, deliveries, and debris removal with the COR. See General Requirements.
E. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. All temporary doors shall be accessible to maintenance personnel to gain access to maintenance rooms inside construction areas. Coordinate final door locations with COR.
F. All existing doors to surrounding a construction phase must be sealed to prevent the passage of smoke. Install plastic zipper walls at all entrances to construction phases.
G. Existing utilities shall remain in operation during construction.
H. Provide and maintain negative air pressure inside construction zone.
I. All marked exits shall be maintained throughout construction. If an exit is required to be blocked temporary signage must be installed to direct to the nearest exit. Coordinate closing of exits with COR.
J. Verify proper fire stopping is installed at penetrations of rated walls.
P-1/64
P-2/64
S-4/64
S-3/64
C B
AB22B
AB21 AB13
AB19
ABO8B
ABO5C
ABO5E
ABO5D
ABO5B
C B
AB28
AB29
AB22D
AB28A
AB23
AB22C
AB23A
AB21B
AB27
AB22
AB26
AB22A
AB21A
AB21C AB21D
AB18B
AB18C AB18D
AB18A
AB16
AB14
AB15
AB17
AB19A
AB17A
AB12
AB11
AB25ABO5A
ABO5
ABO8A ABO8
ABO6ABO7A
ABO7
ABO4
ABO2
ABO1
ABO9
AB10
ABO6A
ABO9A
AB11A
AB12A
AB12B
C B
CB-4
CB-3
CB-3
C B
AB28
AB29
BB03A
BB03
C B
AB28B
BB06
AB28A
C B
C15
C8
CB-3 CB-3
C7A
C7
AB20B
MECH.
RM.
STAIR
STAIR
STAIR
F.A.C.
UTIL.
TUNNEL/AREAWAY
OFC.
LINEN
CHUTE
GAS
STERILE & NON-STERILE
STORAGE
PREP. &
STERILIZATION
SOILED
RECIEVING
DECONTAMINATION
STOR.
TISSUE
STOR.
SPDFEM.
TOIL.
MORT.
REFRIG.
HAC
STORAGE
S.TOIL.
ELEC.
TECH. COMP.
SPEC.
LEAD.
SPEC.
CORRIDOR
LINEN
CHUTE
IRMS
STOR.
EMS
STOR.
EMS.
SUPRINT
DEC.
SUPR.
MECH.
RM.
EMS
STOR.
PATIENT
CLOTHINGROOM
F.A.C.
EL.CL.
SPD
MALETOIL
S V C E L E V
L O B B Y
AUTOPSY
ROOM
MECH
RM.
MECH. EQUIP.
RM.
A/C
SHOP LINEN
FORMS
FIRE ALARM
SYSTEMENG.
STORAGE
EMS
STOR.
CONFERANCE
ROOM
EMS
STOR.
MECH.
ROOM
FORMS
STORAGE
EMS
STOR. SUPR.
OFC.
EMS
STORAGESIGN
SHOP
DISPATCH
EMS
STOR.
CHUTE
MECH.
STOR.
CORRIDOR
CORRIDOR
STEAM
ROOM
STORAGE
MASONRY
SHOP
C O R R
ID
O R
P A S S .E L E V
L O B B Y
C O R R
ID
O R
DISPATCH
CHIEF
SPD CLERICAL
SPD
C O R R
ID
O R
RECIEVING
SPD
CLEAN
STORAGE
SPD STERILE & NON
STERILE
STAIR
CORRIDOR CORRIDOR
RECPT.
EMS.
ASST.CHIEF
SUPR.
0-HR Smoke Partition - NFPA 101 - 8.4
1-HR Smoke Barrier - NFPA 101 - 8.5
1-HR Fire Barrier - NFPA 101 - 8.3
2-HR Fire Barrier - NFPA 101 - 8.3
Means of Egress
Existing Wall to Remain
Proposed Temporary Wall Location - Wall Type T1.0
CODE LEGEND
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
/2
/2
:4
:1
P
M
REPLACE PLUMBING
SYSTEMS IN BLDG. 64
08/27/2021
LIFE SAFETY& PHASING PLANS
G103
NSJR
573A4-18-600
Lake City, Florida
PAUL DRAKE
100% CONSTRUCTION
DOCUMENTS
N Scale: 1/8" = 1'-0"
CODE PLAN - PHASE 3
GENERAL PHASING NOTES
A. Temporary partition to structural deck above. If temporary partition cannot be built to deck due to utilities above the ceiling a fire retardant plastic may be used from the suspended ceiling to the structural deck to seal up construction area and enable a negative air construction zone.
B. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the COR.
C. Coordinate phase completion with requirements as set for by COR to maintain daily operations to near as normal as possible.
D. Coordinate access to all phases of construction, deliveries, and debris removal with the COR. See General Requirements.
E. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. All temporary doors shall be accessible to maintenance personnel to gain access to maintenance rooms inside construction areas. Coordinate final door locations with COR.
F. All existing doors to surrounding a construction phase must be sealed to prevent the passage of smoke. Install plastic zipper walls at all entrances to construction phases.
G. Existing utilities shall remain in operation during construction.
H. Provide and maintain negative air pressure inside construction zone.
I. All marked exits shall be maintained throughout construction. If an exit is required to be blocked temporary signage must be installed to direct to the nearest exit. Coordinate closing of exits with COR.
P-1/64
P-2/64
S-4/64
S-3/64
C B
AB22B
AB21 AB13
AB19
ABO8B
ABO5C
ABO5E
ABO5D
ABO5B
C B
AB28
AB29
AB22D
AB28A
AB23
AB22C
AB23A
AB21B
AB27
AB22
AB26
AB22A
AB21A
AB21C AB21D
AB18B
AB18C AB18D
AB18A
AB16
AB14
AB15
AB17
AB19A
AB17A
AB12
AB11
AB25ABO5A
ABO5
ABO8A ABO8
ABO6ABO7A
ABO7
ABO4
ABO2
ABO1
ABO9
AB10
ABO6A
ABO9A
AB11A
AB12A
AB12B
C B
CB-4
CB-3
CB-3
C B
AB28
AB29
BB03A
BB03
C B
AB28B
BB06
AB28A
C B
C15
C8
CB-3 CB-3
C7A
C7
AB20B
MECH.
RM.
STAIR
STAIR
STAIR
F.A.C.
UTIL.
TUNNEL/AREAWAY
OFC.
LINEN
CHUTE
GAS
STERILE & NON-STERILE
STORAGE
PREP. &
STERILIZATION
SOILED
RECIEVING
DECONTAMINATION
STOR.
TISSUE
STOR.
SPDFEM.
TOIL.
MORT.
REFRIG.
HAC
STORAGE
S.TOIL.
ELEC.
TECH. COMP.
SPEC.
LEAD.
SPEC.
CORRIDOR
LINEN
CHUTE
IRMS
STOR.
EMS
STOR.
EMS.
SUPRINT
DEC.
SUPR.
MECH.
RM.
EMS
STOR.
PATIENT
CLOTHINGROOM
F.A.C.
EL.CL.
SPD
MALETOIL
S V C E L E V
L O B B Y
AUTOPSY
ROOM
MECH
RM.
MECH. EQUIP.
RM.
A/C
SHOP LINEN
FORMS
FIRE ALARM
SYSTEMENG.
STORAGE
EMS
STOR.
CONFERANCE
ROOM
EMS
STOR.
MECH.
ROOM
FORMS
STORAGE
EMS
STOR. SUPR.
OFC.
EMS
STORAGESIGN
SHOP
DISPATCH
EMS
STOR.
CHUTE
MECH.
STOR.
CORRIDOR
CORRIDOR
STEAM
ROOM
STORAGE
MASONRY
SHOP
C O R R
ID
O R
P A S S .E L E V
L O B B Y
C O R R
ID
O R
DISPATCH
CHIEF
SPD CLERICAL
SPD
C O R R
ID
O R
RECIEVING
SPD
CLEAN
STORAGE
SPD STERILE & NON
STERILE
STAIR
CORRIDOR CORRIDOR
RECPT.
EMS.
ASST.CHIEF
SUPR.
0-HR Smoke Partition - NFPA 101 - 8.4
1-HR Smoke Barrier - NFPA 101 - 8.5
1-HR Fire Barrier - NFPA 101 - 8.3
2-HR Fire Barrier - NFPA 101 - 8.3
Means of Egress
Existing Wall to Remain
Proposed Temporary Wall Location - Wall Type T1.0
CODE LEGEND
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
/2
/2
:4
:1
P
M
REPLACE PLUMBING
SYSTEMS IN BLDG. 64
08/27/2021
LIFE SAFETY & PHASING PLANS
G104
NSJR
573A4-18-600
Lake City, Florida
PAUL DRAKE
100% CONSTRUCTION
DOCUMENTS
N Scale: 1/8" = 1'-0"
CODE PLAN - PHASE 4
GENERAL PHASING NOTES
A. Temporary partition to structural deck above. If temporary partition cannot be built to deck due to utilities above the ceiling a fire retardant plastic may be used from the suspended ceiling to the structural deck to seal up construction area and enable a negative air construction zone.
B. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the COR.
C. Coordinate phase completion with requirements as set for by COR to maintain daily operations to near as normal as possible.
D. Coordinate access to all phases of construction, deliveries, and debris removal with the COR. See General Requirements.
E. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. All temporary doors shall be accessible to maintenance personnel to gain access to maintenance rooms inside construction areas. Coordinate final door locations with COR.
F. All existing doors to surrounding a construction phase must be sealed to prevent the passage of smoke. Install plastic zipper walls at all entrances to construction phases.
G. Existing utilities shall remain in operation during construction.
H. Provide and maintain negative air pressure inside construction zone.
I. All marked exits shall be maintained throughout construction. If an exit is required to be blocked temporary signage must be installed to direct to the nearest exit. Coordinate closing of exits with COR.
P-1/64
P-2/64
S-4/64
S-3/64
C B
AB22B
AB21 AB13
AB19
ABO8B
ABO5C
ABO5E
ABO5D
ABO5B
C B
AB28
AB29
AB22D
AB28A
AB23
AB22C
AB23A
AB21B
AB27
AB22
AB26
AB22A
AB21A
AB21C AB21D
AB18B
AB18C AB18D
AB18A
AB16
AB14
AB15
AB17
AB19A
AB17A
AB12
AB11
AB25ABO5A
ABO5
ABO8A ABO8
ABO6ABO7A
ABO7
ABO4
ABO2
ABO1
ABO9
AB10
ABO6A
ABO9A
AB11A
AB12A
AB12B
C B
CB-4
CB-3
CB-3
C B
AB28
AB29
BB03A
BB03
C B
AB28B
BB06
AB28A
C B
C15
C8
CB-3 CB-3
C7A
C7
AB20B
MECH.
RM.
STAIR
STAIR
STAIR
F.A.C.
UTIL.
TUNNEL/AREAWAY
OFC.
LINEN
CHUTE
GAS
STERILE & NON-STERILE
STORAGE
PREP. &
STERILIZATION
SOILED
RECIEVING
DECONTAMINATION
STOR.
TISSUE
STOR.
SPDFEM.
TOIL.
MORT.
REFRIG.
HAC
STORAGE
S.TOIL.
ELEC.
TECH. COMP.
SPEC.
LEAD.
SPEC.
CORRIDOR
LINEN
CHUTE
IRMS
STOR.
EMS
STOR.
EMS.
SUPRINT
DEC.
SUPR.
MECH.
RM.
EMS
STOR.
PATIENT
CLOTHINGROOM
F.A.C.
EL.CL.
SPD
MALETOIL
S V C E L E V
L O B B Y
AUTOPSY
ROOM
MECH
RM.
MECH. EQUIP.
RM.
A/C
SHOP LINEN
FORMS
FIRE ALARM
SYSTEMENG.
STORAGE
EMS
STOR.
CONFERANCE
ROOM
EMS
STOR.
MECH.
ROOM
FORMS
STORAGE
EMS
STOR. SUPR.
OFC.
EMS
STORAGESIGN
SHOP
DISPATCH
EMS
STOR.
CHUTE
MECH.
STOR.
CORRIDOR
CORRIDOR
STEAM
ROOM
STORAGE
MASONRY
SHOP
C O R R
ID
O R
P A S S .E L E V
L O B B Y
C O R R
ID
O R
DISPATCH
CHIEF
SPD CLERICAL
SPD
C O R R
ID
O R
RECIEVING
SPD
CLEAN
STORAGE
SPD STERILE & NON
STERILE
STAIR
CORRIDOR CORRIDOR
RECPT.
EMS.
ASST.CHIEF
SUPR.
0-HR Smoke Partition - NFPA 101 - 8.4
1-HR Smoke Barrier - NFPA 101 - 8.5
1-HR Fire Barrier - NFPA 101 - 8.3
2-HR Fire Barrier - NFPA 101 - 8.3
Means of Egress
Existing Wall to Remain
Proposed Temporary Wall Location - Wall Type T1.0
CODE LEGEND
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
/2
/2
:4
:1
P
M
REPLACE PLUMBING
SYSTEMS IN BLDG. 64
08/27/2021
LIFE SAFETY & PHASING PLANS
G105
NSJR
573A4-18-600
Lake City, Florida
PAUL DRAKE
100% CONSTRUCTION
DOCUMENTS
GENERAL PHASING NOTES
A. Temporary partition to structural deck above. If temporary partition cannot be built to deck due to utilities above the ceiling a fire retardant plastic may be used from the suspended ceiling to the structural deck to seal up construction area and enable a negative air construction zone.
B. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the COR.
C. Coordinate phase completion with requirements as set for by COR to maintain daily operations to near as normal as possible.
D. Coordinate access to all phases of construction, deliveries, and debris removal with the COR. See General Requirements.
E. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. All temporary doors shall be accessible to maintenance personnel to gain access to maintenance rooms inside construction areas. Coordinate final door locations with COR.
F. All existing doors to surrounding a construction phase must be sealed to prevent the passage of smoke. Install plastic zipper walls at all entrances to construction phases.
G. Existing utilities shall remain in operation during construction.
H. Provide and maintain negative air pressure inside construction zone.
I. All marked exits shall be maintained throughout construction. If an exit is required to be blocked temporary signage must be installed to direct to the nearest exit. Coordinate closing of exits with COR.
J. Verify proper fire stopping is installed at penetrations of rated walls.
N Scale: 1/8" = 1'-0"
CODE PLAN - PHASE 5
P-1/64
P-2/64
S-4/64
S-3/64
C B
AB22B
AB21 AB13
AB19
ABO8B
ABO5C
ABO5E
ABO5D
ABO5B
C B
AB28
AB29
AB22D
AB28A
AB23
AB22C
AB23A
AB21B
AB27
AB22
AB26
AB22A
AB21A
AB21C AB21D
AB18B
AB18C AB18D
AB18A
AB16
AB14
AB15
AB17
AB19A
AB17A
AB12
AB11
AB25ABO5A
ABO5
ABO8A ABO8
ABO6ABO7A
ABO7
ABO4
ABO2
ABO1
ABO9
AB10
ABO6A
ABO9A
AB11A
AB12A
AB12B
C B
CB-4
CB-3
CB-3
C B
AB28
AB29
BB03A
BB03
C B
AB28B
BB06
AB28A
C8
CB-3 CB-3
C7A
C7
AB18G
AB20B AB20 AB20A
AB18
AB
18F
MECH.
RM.
STAIR
STAIR
STAIR
F.A.C.
UTIL.
TUNNEL/AREAWAY
OFC.
LINEN
CHUTE
GAS
STERILE & NON-STERILE
STORAGE
PREP. &
STERILIZATION
SOILED
RECIEVING
DECONTAMINATION
STOR.
TISSUE
STOR.
SPDFEM.
TOIL.
MORT.
REFRIG.
HAC
STORAGE
S.TOIL.
ELEC.
TECH. COMP.
SPEC.
LEAD.
SPEC.
CORRIDOR
LINEN
CHUTE
IRMS
STOR.
EMS
STOR.
EMS.
SUPRINT
DEC.
SUPR.
MECH.
RM.
EMS
STOR.
PATIENT
CLOTHINGROOM
F.A.C.
EL.CL.
SPD
MALETOIL
S V C E L E V
L O B B Y
AUTOPSY
ROOM
MECH
RM.
MECH. EQUIP.
RM.
LINEN
FORMS
FIRE ALARM
SYSTEMENG.
STORAGE
EMS
STOR.
CONFERANCE
ROOM
EMS
STOR.
MECH.
ROOM
FORMS
STORAGE
EMS
STOR. SUPR.
OFC.
EMS
STORAGESIGN
SHOP
DISPATCH
EMS
STOR.
CHUTE
MECH.
STOR.
CORRIDOR
CORRIDOR
STEAM
ROOM
STORAGE
MASONRY
SHOP
C O R R
ID
O R
P A S S .E L E V
L O B B Y
C O R R
ID
O R
DISPATCH
CHIEF
SPD CLERICAL
SPD
C O R R
ID
O R
RECIEVING
SPD
CLEAN
STORAGE
SPD STERILE & NON
STERILE
CORRIDOR CORRIDOR
CLASS
ROOM
CHIEF
EMS
RECPT.
EMS.
ASST.CHIEF SECT./RECPT.
SUPR.
0-HR Smoke Partition - NFPA 101 - 8.4
1-HR Smoke Barrier - NFPA 101 - 8.5
1-HR Fire Barrier - NFPA 101 - 8.3
2-HR Fire Barrier - NFPA 101 - 8.3
Means of Egress
Existing Wall to Remain
Proposed Temporary Wall Location - Wall Type T1.0
CODE LEGEND
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
/2
/2
:4
:1
P
M
REPLACE PLUMBING
SYSTEMS IN BLDG. 64
08/27/2021
LIFE SAFETY & PHASING PLANS
G106
NSJR
573A4-18-600
Lake City, Florida
PAUL DRAKE
100% CONSTRUCTION
DOCUMENTS
N Scale: 1/8" = 1'-0"
CODE PLAN - PHASE 6
GENERAL PHASING NOTES
A. Temporary partition to structural deck above. If temporary partition cannot be built to deck due to utilities above the ceiling a fire retardant plastic may be used from the suspended ceiling to the structural deck to seal up construction area and enable a negative air construction zone.
B. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the COR.
C. Coordinate phase completion with requirements as set for by COR to maintain daily operations to near as normal as possible.
D. Coordinate access to all phases of construction, deliveries, and debris removal with the COR. See General Requirements.
E. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. All temporary doors shall be accessible to maintenance personnel to gain access to maintenance rooms inside construction areas. Coordinate final door locations with COR.
F. All existing doors to surrounding a construction phase must be sealed to prevent the passage of smoke. Install plastic zipper walls at all entrances to construction phases.
G. Existing utilities shall remain in operation during construction.
H. Provide and maintain negative air pressure inside construction zone.
I. All marked exits shall be maintained throughout construction. If an exit is required to be blocked temporary signage must be installed to direct to the nearest exit. Coordinate closing of exits with COR.
A O V
AB28A
BB25
CB-14
BB27
BB28
BB29
BB26
BB24
BB23BB22
BB26A
BB03A
BB03
CB-7
BB02
BB01
BB04 BB05
BB16
BB07
BB16A
BB20
BB19
BB21 BB21C
BB18
BB17
BB18A
C B
C B
C B
F-5/64
AB28B
BB06
BB14
BB14A
BB15
BB13
BB11A
C B
BB12B
CB-10
BB12
BB11
BB12A
BB10
BB09
BB09A
CB-10
BB10A
BB08
AB30
C B
C10B
C10
C10
C9A
C B A
C9
C9
C9CC9B
C9D
C B
CB-3
C6E C6D C6C
C6B
C6F
C6
C6G
CB-3
C7A
C5
C6A C6
C4
C1
CB-1
C2
C6K
C6H C6J
STAIR
CORRIDOR
M.
TOILET
WELLNESS
CENTER
F.
TOILET
R.M.S.
STORAGE
R.M.S.
STORAGE
H.A.C.F.A.C.
MECH.
ROOM
(UNEXCAVATED)
MECH.
ROOM
CHIEF
SPD CLERICAL
SPD
CORRIDOR
MALE
TOIL,
CL.
LINEN
FEM.
TOIL,
HAC
SPD
STORAGE
T.M.E.R.
SHOP
T.M.E.R.
SHOP
SPD
STORAGE
FREEZER #
M.A.S.
STOR.
E.M.S.
STOR.
ENG.
DIETETICS
STORAGE
D
IE
T E L E V
L O B B Y
C O R R
ID
O R
C O R R
ID
O R
HAC
RECIEVING
SPD
CLEAN
HVAC
MECH.
ROOM
REFRIG.
MECH.
ROOM
EMS
EQUIP.
CLEANING
FREEZER #
C O R R
ID
O R
MEDICAL
MEDIACAMERA
ROOM
CORRIDOR
M.M.
OFC
REFRIG #
PROCESS
ROOM
M.M.
FILM
ILLUS.
RM.
M.M.
REFRIG, #
CORRIDOR
M.M.
EQ.
STOR.DIETETIC
COOLER #
MECH.
RM.
HVAC
STORAGE
SPD STERILE & NON
STERILE
C O R R
ID
O R
C
ORRIDOR
C O R R
ID
O R
CORRIDOR CORRIDOR
C B
C O R R
ID
O R
ELEV.
LOBBY
PASS.
0-HR Smoke Partition - NFPA 101 - 8.4
1-HR Smoke Barrier - NFPA 101 - 8.5
1-HR Fire Barrier - NFPA 101 - 8.3
2-HR Fire Barrier - NFPA 101 - 8.3
Means of Egress
Existing Wall to Remain
Proposed Temporary Wall Location - Wall Type T1.0
CODE LEGEND
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
/2
/2
:4
:1
P
M
REPLACE PLUMBING
SYSTEMS IN BLDG. 64
08/27/2021
LIFE SAFETY & PHASING PLANS
G107
NSJR
573A4-18-600
Lake City, Florida
PAUL DRAKE
100% CONSTRUCTION
DOCUMENTS
N Scale: 1/8" = 1'-0"
CODE PLAN - PHASE 7
GENERAL PHASING NOTES
A. Temporary partition to structural deck above. If temporary partition cannot be built to deck due to utilities above the ceiling a fire retardant plastic may be used from the suspended ceiling to the structural deck to seal up construction area and enable a negative air construction zone.
B. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the COR.
C. Coordinate phase completion with requirements as set for by COR to maintain daily operations to near as normal as possible.
D. Coordinate access to all phases of construction, deliveries, and debris removal with the COR. See General Requirements.
E. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. All temporary doors shall be accessible to maintenance personnel to gain access to maintenance rooms inside construction areas. Coordinate final door locations with COR.
F. All existing doors to surrounding a construction phase must be sealed to prevent the passage of smoke. Install plastic zipper walls at all entrances to construction phases.
G. Existing utilities shall remain in operation during construction.
H. Provide and maintain negative air pressure inside construction zone.
I. All marked exits shall be maintained throughout construction. If an exit is required to be blocked temporary signage must be installed to direct to the nearest exit. Coordinate closing of exits with COR.
V
AB28A
BB25
CB-14
BB27
BB28
BB29
BB26
BB24
BB23BB22
BB26A
BB03A
BB03
CB-7
BB02
BB01
BB04 BB05
BB16
BB07
BB16A
BB20
BB19
BB21 BB21C
BB18
BB17
BB18A
C B
C B
C B
F-5/64
AB28B
BB06
BB14
BB14A
BB15
BB13
BB11A
C B
BB12B
CB-10
BB12
BB11
BB12A
BB10
BB09
BB09A
CB-10
BB10A
BB08
AB30
C B
C10B
C10
C10
C9A
C B A
C9
C9
C9CC9B
C9D
C B
CB-3
C6E C6D C6C
C6B
C6F
C6
C6G
CB-3
C5
C6A C6
C4
C1
CB-1
C2
C6K
C6H C6J
STAIR
CORRIDOR
M.
TOILET
WELLNESS
CENTER
F.
TOILET
R.M.S.
STORAGE
R.M.S.
STORAGE
H.A.C.F.A.C.
MECH.
ROOM
(UNEXCAVATED)
MECH.
ROOM
SPD
CORRIDOR
MALE
TOIL,
CL.
LINEN
FEM.
TOIL,
HAC
SPD
STORAGE
T.M.E.R.
SHOP
T.M.E.R.
SHOP
SPD
STORAGE
FREEZER #
M.A.S.
STOR.
E.M.S.
STOR.
ENG.
DIETETICS
STORAGE
D
IE
T E L E V
L O B B Y
C O R R
ID
O R
C O R R
ID
O R
HAC
SPD
HVAC
MECH.
ROOM
REFRIG.
MECH.
ROOM
EMS
EQUIP.
CLEANING
FREEZER #
C O R R
ID
O R
MEDICAL
MEDIACAMERA
ROOM
CORRIDOR
M.M.
OFC
REFRIG #
PROCESS
ROOM
M.M.
FILM
ILLUS.
RM.
M.M.
REFRIG, #
CORRIDOR
M.M.
EQ.
STOR.DIETETIC
COOLER #
MECH.
RM.
HVAC
SPD STERILE & NON
C O R R
ID
O R
C
ORRIDOR
C O R R
ID
O R
CORRIDOR CORRIDOR
C B
C O R R
ID
O R
ELEV.
LOBBY
PASS.
0-HR Smoke Partition - NFPA 101 - 8.4
1-HR Smoke Barrier - NFPA 101 - 8.5
1-HR Fire Barrier - NFPA 101 - 8.3
2-HR Fire Barrier - NFPA 101 - 8.3
Means of Egress
Existing Wall to Remain
Proposed Temporary Wall Location - Wall Type T1.0
CODE LEGEND
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
/2
/2
:4
:1
P
M
REPLACE PLUMBING
SYSTEMS IN BLDG. 64
08/27/2021
LIFE SAFETY & PHASING PLANS
G108
NSJR
573A4-18-600
Lake City, Florida
PAUL DRAKE
100% CONSTRUCTION
DOCUMENTS
N Scale: 1/8" = 1'-0"
CODE PLAN - PHASE 8
GENERAL PHASING NOTES
A. Temporary partition to structural deck above. If temporary partition cannot be built to deck due to utilities above the ceiling a fire retardant plastic may be used from the suspended ceiling to the structural deck to seal up construction area and enable a negative air construction zone.
B. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the COR.
C. Coordinate phase completion with requirements as set for by COR to maintain daily operations to near as normal as possible.
D. Coordinate access to all phases of construction, deliveries, and debris removal with the COR. See General Requirements.
E. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. All temporary doors shall be accessible to maintenance personnel to gain access to maintenance rooms inside construction areas. Coordinate final door locations with COR.
F. All existing doors to surrounding a construction phase must be sealed to prevent the passage of smoke. Install plastic zipper walls at all entrances to construction phases.
G. Existing utilities shall remain in operation during construction.
H. Provide and maintain negative air pressure inside construction zone.
I. All marked exits shall be maintained throughout construction. If an exit is required to be blocked temporary signage must be installed to direct to the nearest exit. Coordinate closing of exits with COR.
V
AB29
AB22D
AB28A
BB25
CB-14
BB27
BB28
BB29
BB26
BB24
BB23BB22
BB26A
AB29
BB03A
BB03
CB-7
C B
BB02
BB01
BB04 BB05
BB16
BB07
BB16A
BB20
BB19
BB21 BB21C
BB18
BB17
BB18A
C B
C B
C B
F-5/64
AB28B
BB06
BB14
BB14A
BB15
BB13
BB11A
C B
BB12B
CB-10
BB12
BB11
BB12A
BB10
BB09
BB09A
CB-10
BB10A
BB08
AB30
AB28A
C B
C10B
C10
C10
C9A
C B A
C9
C9
C9CC9B
C9D
C B
C15
C8
CB-3
C6E C6D C6C
C6B
C6F
C6
C6G
CB-3
C7A
C5
C6A C6
C4
C1
CB-1
C2
C6K
C6H C6J
C7
LINEN
CHUTE
GAS
STERILE & NON-STERILE
STORAGE
STOR.
STAIR
CORRIDOR
M.
TOILET
WELLNESS
CENTER
F.
TOILET
R.M.S.
STORAGE
R.M.S.
STORAGE
H.A.C.F.A.C.
MECH.
ROOM
(UNEXCAVATED)
MECH.
ROOM
CHIEF
SPD CLERICAL
SPD
CORRIDOR
C O R R
ID
O R
MALE
TOIL,
CL.
LINEN
FEM.
TOIL,
HAC
SPD
STORAGE
T.M.E.R.
SHOP
T.M.E.R.
SHOP
SPD
STORAGE
FREEZER #
M.A.S.
STOR.
E.M.S.
STOR.
ENG.
DIETETICS
STORAGE
D
IE
T E L E V
L O B B Y
C O R R
ID
O R
C O R R
ID
O R
HAC
RECIEVING
SPD
CLEAN
HVAC
MECH.
ROOM
REFRIG.
MECH.
ROOM
EMS
EQUIP.
CLEANING
FREEZER #
C O R R
ID
O R
MEDICAL
MEDIACAMERA
ROOM
CORRIDOR
M.M.
OFC
REFRIG #
PROCESS
ROOM
M.M.
FILM
ILLUS.
RM.
M.M.
REFRIG, #
CORRIDOR
M.M.
EQ.
STOR.DIETETIC
COOLER #
MECH.
RM.
HVAC
STORAGE
SPD STERILE & NON
STERILE
C O R R
ID
O R
C
ORRIDOR
C O R R
ID
O R
STAIR
CORRIDOR CORRIDOR
C B
C O R R
ID
O R
ELEV.
LOBBY
PASS.
0-HR Smoke Partition - NFPA 101 - 8.4
1-HR Smoke Barrier - NFPA 101 - 8.5
1-HR Fire Barrier - NFPA 101 - 8.3
2-HR Fire Barrier - NFPA 101 - 8.3
Means of Egress
Existing Wall to Remain
Proposed Temporary Wall Location - Wall Type T1.0
CODE LEGEND
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
/2
/2
:4
:1
P
M
REPLACE PLUMBING
SYSTEMS IN BLDG. 64
08/27/2021
LIFE SAFETY & PHASING PLANS
G109
NSJR
573A4-18-600
Lake City, Florida
PAUL DRAKE
100% CONSTRUCTION
DOCUMENTS
N Scale: 1/8" = 1'-0"
CODE PLAN - PHASE 9
GENERAL PHASING NOTES
A. Temporary partition to structural deck above. If temporary partition cannot be built to deck due to utilities above the ceiling a fire retardant plastic may be used from the suspended ceiling to the structural deck to seal up construction area and enable a negative air construction zone.
B. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the COR.
C. Coordinate phase completion with requirements as set for by COR to maintain daily operations to near as normal as possible.
D. Coordinate access to all phases of construction, deliveries, and debris removal with the COR. See General Requirements.
E. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. All temporary doors shall be accessible to maintenance personnel to gain access to maintenance rooms inside construction areas. Coordinate final door locations with COR.
F. All existing doors to surrounding a construction phase must be sealed to prevent the passage of smoke. Install plastic zipper walls at all entrances to construction phases.
G. Existing utilities shall remain in operation during construction.
H. Provide and maintain negative air pressure inside construction zone.
I. All marked exits shall be maintained throughout construction. If an exit is required to be blocked temporary signage must be installed to direct to the nearest exit. Coordinate closing of exits with COR.
V
AB28A
BB25
CB-14
BB27
BB28
BB29
BB26
BB24
BB23BB22
BB26A
AB29
BB03A
BB03
CB-7
C B
BB02
BB01
BB04 BB05
BB16
BB07
BB16A
BB20
BB19
BB21 BB21C
BB18
BB17
BB18A
C B
C B
C B
F-5/64
AB28B
BB06
BB14
BB14A
BB15
BB13
BB11A
C B
BB12B
CB-10
BB12
BB11
BB12A
BB10
BB09
BB09A
CB-10
BB10A
BB08
AB30
AB28A
C B
C10B
C10
C10
C9A
C B A
C9
C9
C9CC9B
C9D
C B
C8
CB-3
C6E C6D C6C
C6B
C6F
C6
C6G
CB-3
C7A
C5
C6A C6
C4
C1
CB-1
C2
C6K
C6H C6J
C7
LINEN
CHUTE
STERILE & NON-STERILE
STORAGE
STAIR
CORRIDOR
M.
TOILET
WELLNESS
CENTER
F.
TOILET
R.M.S.
STORAGE
R.M.S.
STORAGE
H.A.C.F.A.C.
MECH.
ROOM
(UNEXCAVATED)
MECH.
ROOM
CHIEF
SPD CLERICAL
SPD
CORRIDOR
C O R R
ID
O R
MALE
TOIL,
CL.
LINEN
FEM.
TOIL,
HAC
SPD
STORAGE
T.M.E.R.
SHOP
T.M.E.R.
SHOP
SPD
STORAGE
FREEZER #
M.A.S.
STOR.
E.M.S.
STOR.
ENG.
DIETETICS
STORAGE
D
IE
T E L E V
L O B B Y
C O R R
ID
O R
C O R R
ID
O R
HAC
RECIEVING
SPD
CLEAN
HVAC
MECH.
ROOM
REFRIG.
MECH.
ROOM
EMS
EQUIP.
CLEANING
FREEZER #
C O R R
ID
O R
MEDICAL
MEDIACAMERA
ROOM
CORRIDOR
M.M.
OFC
REFRIG #
PROCESS
ROOM
M.M.
FILM
ILLUS.
RM.
M.M.
REFRIG, #
CORRIDOR
M.M.
EQ.
STOR.DIETETIC
COOLER #
MECH.
RM.
HVAC
STORAGE
SPD STERILE & NON
STERILE
C O R R
ID
O R
C
ORRIDOR
C O R R
ID
O R
STAIR
CORRIDOR CORRIDOR
C B
C O R R
ID
O R
ELEV.
LOBBY
PASS.
0-HR Smoke Partition - NFPA 101 - 8.4
1-HR Smoke Barrier - NFPA 101 - 8.5
1-HR Fire Barrier - NFPA 101 - 8.3
2-HR Fire Barrier - NFPA 101 - 8.3
Means of Egress
Existing Wall to Remain
Proposed Temporary Wall Location - Wall Type T1.0
CODE LEGEND
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
/2
/2
:4
:1
P
M
REPLACE PLUMBING
SYSTEMS IN BLDG. 64
08/27/2021
LIFE SAFETY & PHASING PLANS
G110
NSJR
573A4-18-600
Lake City, Florida
PAUL DRAKE
100% CONSTRUCTION
DOCUMENTS
N Scale: 1/8" = 1'-0"
CODE PLAN - PHASE 10
GENERAL PHASING NOTES
A. Temporary partition to structural deck above. If temporary partition cannot be built to deck due to utilities above the ceiling a fire retardant plastic may be used from the suspended ceiling to the structural deck to seal up construction area and enable a negative air construction zone.
B. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the COR.
C. Coordinate phase completion with requirements as set for by COR to maintain daily operations to near as normal as possible.
D. Coordinate access to all phases of construction, deliveries, and debris removal with the COR. See General Requirements.
E. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. All temporary doors shall be accessible to maintenance personnel to gain access to maintenance rooms inside construction areas. Coordinate final door locations with COR.
F. All existing doors to surrounding a construction phase must be sealed to prevent the passage of smoke. Install plastic zipper walls at all entrances to construction phases.
G. Existing utilities shall remain in operation during construction.
H. Provide and maintain negative air pressure inside construction zone.
I. All marked exits shall be maintained throughout construction. If an exit is required to be blocked temporary signage must be installed to direct to the nearest exit. Coordinate closing of exits with COR.
V
AB28A
BB25
CB-14
BB27
BB28
BB29
BB26
BB24
BB23BB22
BB26A
BB03A
BB03
CB-7
BB02
BB01
BB04 BB05
BB16
BB07
BB16A
BB20
BB19
BB21 BB21C
BB18
BB17
BB18A
C B
C B
C B
F-5/64
AB28B
BB06
BB14
BB14A
BB15
BB13
BB11A
C B
BB12B
CB-10
BB12
BB11
BB12A
BB10
BB09
BB09A
CB-10
BB10A
BB08
AB30
C B
C10B
C10
C10
C9A
C B A
C9
C9
C9CC9B
C9D
C B
CB-3
C6E C6D C6C
C6B
C6F
C6
C6G
CB-3
C7A
C5
C6A C6
C4
C1
CB-1
C2
C6K
C6H C6J
STAIR
CORRIDOR
M.
TOILET
WELLNESS
CENTER
F.
TOILET
R.M.S.
STORAGE
R.M.S.
STORAGE
H.A.C.F.A.C.
MECH.
ROOM
(UNEXCAVATED)
MECH.
ROOM
CHIEF
SPD CLERICAL
SPD
CORRIDOR
MALE
TOIL,
CL.
LINEN
FEM.
TOIL,
HAC
SPD
STORAGE
T.M.E.R.
SHOP
T.M.E.R.
SHOP
SPD
STORAGE
FREEZER #
M.A.S.
STOR.
E.M.S.
STOR.
ENG.
DIETETICS
STORAGE
D
IE
T E L E V
L O B B Y
C O R R
ID
O R
C O R R
ID
O R
HAC
RECIEVING
SPD
CLEAN
HVAC
MECH.
ROOM
REFRIG.
MECH.
ROOM
EMS
EQUIP.
CLEANING
FREEZER #
C O R R
ID
O R
MEDICAL
MEDIACAMERA
ROOM
CORRIDOR
M.M.
OFC
REFRIG #
PROCESS
ROOM
M.M.
FILM
ILLUS.
RM.
M.M.
REFRIG, #
CORRIDOR
M.M.
EQ.
STOR.DIETETIC
COOLER #
MECH.
RM.
HVAC
STORAGE
SPD STERILE & NON
STERILE
C O R R
ID
O R
C
ORRIDOR
C O R R
ID
O R
CORRIDOR CORRIDOR
C B
C O R R
ID
O R
ELEV.
LOBBY
PASS.
0-HR Smoke Partition - NFPA 101 - 8.4
1-HR Smoke Barrier - NFPA 101 - 8.5
1-HR Fire Barrier - NFPA 101 - 8.3
2-HR Fire Barrier - NFPA 101 - 8.3
Means of Egress
Existing Wall to Remain
Proposed Temporary Wall Location - Wall Type T1.0
CODE LEGEND
JOHN
A.
POE
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
3131 Newmark Drive, Suite 200 Miamisburg, Ohio 45342 |www.johnpoe.com| 937.461.3290
VA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
/2
/2
:4
:1
P
M
REPLACE PLUMBING
SYSTEMS IN BLDG. 64
08/27/2021
LIFE SAFETY & PHASING PLANS
G111
NSJR
573A4-18-600
Lake City, Florida
PAUL DRAKE
100% CONSTRUCTION
DOCUMENTS
N Scale: 1/8" = 1'-0"
CODE PLAN - PHASE 11
GENERAL PHASING NOTES
A. Temporary partition to structural deck above. If temporary partition cannot be built to deck due to utilities above the ceiling a fire retardant plastic may be used from the suspended ceiling to the structural deck to seal up construction area and enable a negative air construction zone.
B. Coordinate all work involving the generation of excessive noise so as to occur during non-peak operating hours, 1000 to 1600 daily.
Activities to occur during this time include, but are not limited to saw cutting, jack hammering, hammer drilling and core drilling. If there is any question as to whether an operation should occur during this time the Contractor will contact the COR.
C. Coordinate phase completion with requirements as set for by COR to maintain daily operations to near as normal as possible.
D. Coordinate access to all phases of construction, deliveries, and debris removal with the COR. See General Requirements.
E. Temporary door locations and sizes are as required by the General Contractor. Doors will interfere with daily operations as little as possible. All temporary doors shall be accessible to maintenance personnel to gain access to maintenance rooms inside construction areas. Coordinate final door locations with COR.
F. All existing doors to surrounding a construction phase must be sealed to prevent the passage of smoke. Install plastic zipper walls at all entrances to construction phases.
G. Existing utilities shall remain in operation during construction.
H. Provide and maintain negative air pressure inside construction zone.
I. All marked exits shall be maintained throughout construction. If an exit is required to be blocked temporary signage must be installed to direct to the nearest exit. Coordinate closing of exits with COR.
GENERAL NOTES
1. THE PLUMBING INSTALLATION SHALL COMPLY
WITH ALL CURRENT STATE AND LOCAL
CODES.
2. PROVIDE ALL OFFSETS AND FITTINGS AND
MAKE CONNECTION TO SITE UTILITIES.
3. CONCEAL PIPING ABOVE CEILINGS, WITHIN
WALLS OR CHASES EXCEPT IN MECHANICAL
ROOMS OR AS SPECIFICALLY NOTED.
4. PROVIDE ACCESS PANELS FOR ALL VALVES
CONCEALED IN WALLS OR ABOVE NON-
ACCESSIBLE CEILINGS.
5. SLEEVE AND/OR FIRESTOP ALL PENETRATIONS
THROUGH RATED WALLS, CEILINGS, AND
FLOORS WITH U/L LISTED ASSEMBLIES.
FIRESTOP ASSEMBLIES SHALL BE EQUAL TO
OR EXCEED THE RATING OF THE WALL,
CEILING OR FLOOR. SEE ARCHITECTURAL
DRAWINGS FOR FINAL FINISHES.
6. PROVIDE AN AIR GAP, WHEN REQUIRED BY
CODE, SERVING INDIVIDUAL FIXTURES,
DEVICES, APPLIANCES AND APPARATUS.
7. PROVIDE CLEANOUTS AS REQUIRED BY CODE
OR IN ADDITION TO THOSE SHOWN ON PLAN
IF AN ALTERNATE ROUTE IS CHOSEN BY
CONTRACTOR. INSTALL CLEANOUT WITH COVER
FLUSH TO FINISHED SURFACE
8. CONTRACTOR TO PROVIDE ALL
APPURTENANCES TO COMPLETE INSTALLATION
AND CONNECTIONS IN ITS ENTIRETY TO
FIXTURES AND EQUIPMENT.
9. LEAK TEST TO BE PERFORMED ON SANITARY
PIPING PER SPECIFICATION SECTION
22 13 00, 3.5 TESTS.
10. WHEN SUMP PUMP AND TEMPORARY PIPING
IS REMOVED AFTER A PHASE IS COMPLETED,
THE WYE FITTING IS TO BE CAPPED AT THE
MAIN AS A CLEANOUT.
11. CONTRACTOR TO SUBMIT AN APPROXIMATE
TIMELINE OF SHUTDOWNS FOR THE PROJECT
WHEN SUBMITTING A BID. BEFORE ANY WORK
BEGINS, THE CONTRACTOR MUST RECEIVE VA
COR APPROVAL ON A SCHEDULE FOR
SHUTDOWNS. AFTER APPROVAL, ANY
DEVIATION FROM THIS SCHEDULE NEEDS TO
BE COMMUNICATED WITH THE VA COR AND
RECEIVE THE VA COR APPROVAL.
PLUMBING VALVE SYMBOLS
BALL VALVE
GATE VALVE WITH 3/4 " HOSE ADAPTER
CHECK VALVE
ANGLE GLOBE VALVE
BUTTERFLY VALVE
MODULATING CONTROL VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
AUTOMATIC FLOW CONTROL VALVE
PRESSURE RELIEF VALVE
GATE VALVE
MANUAL AIR VENT
TEST PLUG
(PRESSURE/TEMPERATURE)
GLOBE VALVE
PRESSURE REGULATING VALVE
THREE-WAY TWO POSITION CONTROL VALVE
AUTOMATIC AIR VENTAV
GENERAL PLUMBING SYMBOLS
LIMIT OF DEMOLITION
ANCHOR
REDUCER OR INCREASER
DIRECTION OF FLOW
SIDE…