This document contains architectural drawings and specifications for the Roof Replacement for Buildings 65-66 at 5JD Ft Des Moines in Des Moines, Iowa. The project is being managed by the Iowa Department of Administrative Services, with OPN Architects as the architect and Samuels Group as the construction manager. The scope of work includes demolishing the existing EPDM roof membrane system and insulation, and installing a new 60 mil EPDM roof membrane system with new polyisocyanurate insulation to meet a minimum R-30 value. The contractor is required to identify and replace any deficient plywood roof sheathing. The project must be completed while the facility remains in operation, with coordination required to minimize interference with daily operations. Bids are being solicited under Reference # 005-RFBCON-1124-2024 on the IMPACS system, with a bid set due date of May 22, 2024.

The pricing terms are not specified in the documentation provided. The project is funded by the State of Iowa, but the specific funding sources and amounts are not detailed. There are no indications of any set-aside requirements or incumbent contractors. The contract term and any renewal options are also not provided.

View the file

Other files

File Type Posted
RFB937500-01 - Project Manual.pdf PDF
RFB937500-01 - Notice to Bidders.pdf PDF
RFB937500-01 - Bid Form.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT

LOCATION

PROJECT

LOCATION

N

100 Court Ave. Suite 100, Des Moines, IA 50309

P: 515-309-0722 F: 515-309-0725 www.opnarchitects.com

ARCHITECT

OPN ARCHITECTS

100 COURT AVENUE

DES MOINES, IA 50309

SAMUELS GROUP

2929 WESTOWN PARKWAY, SUITE 200

WEST DES MOINES, IA 50266

CONSTRUCTION MANAGER

9375.00 - DOC 5JD FT DES MOINES BLDG 65-66 ROOF

REPLACEMENT

68 THAYER ST, DES MOINES, IA 50315

B

ID

S E

T

All questions regarding these plans and specifications should be directed to:

NATE STIELER, AIA

Project Manager nstieler@opnarchitects.com 515-309-6882

ARCHITECTURAL DRAWINGS

SHEET

NUMBER SHEET NAME

G000 COVER SHEET

AD101 DEMO ROOF PLAN AND EXISTING CONDITIONS

A101 ROOF PLAN AND DETAILS

SITE LOCATION

GENERAL NOTES

1. DIMENSIONS ARE MEASURED FACE-

OF-FINISH TO FACE-OF-FINISH OR

ROUGH MASONRY OPENING UNLESS

NOTED OTHERWISE - TYPICAL FOR ALL

DRAWINGS.

2. FIELD VERIFY ALL DIMENSIONS AND

EXISTING CONDITIONS - TYPICAL FOR

ALL DRAWINGS.

3. IN THE EVENT OF A DISCREPANCY

BETWEEN ARCHITECTURAL AND

CONSULTANT DRAWINGS, NOTIFY

ARCHITECT IMMEDIATELY PRIOR TO

COMMENCING WORK - TYPICAL FOR

ALL DRAWINGS.

4. THIS FACILITY WILL REMAIN IN

OPERATION THROUGHOUT THE

DURATION OF THE PROJECT.

COORDINATE ALL ROOFING ACTIVITIES

WITH THE OWNER TO MINIMIZE

INTERFERENCE OF DAILY

OPERATIONS.

5. CONTRACTOR TO IDENTIFY AND

REPLACE DEFICIENT PLYWOOD ROOF

SHEATHING, REPLACE PANELS THAT

EXHIBIT SWELLING, BIOLOGICAL

GROWTH OR MOISTURE LEVELS

ABOVE 19%. CONFIRM LOCATIONS W/

ARCHITECT PRIOR TO REPLACING.

6. VERIFY LOCATIONS OF ALL ROOF

PENETRATIONS. PROVIDE BOOTS,

FLASHING AND OTHER ACCESSORIES

REQUIRED TO PROVIDE A COMPLETE,

WATERTIGHT WARRANTED SYSTEM.

7. REPLACE ONLY THE AMOUNT OF

ROOFING THAT CAN BE COMPLETED

AND MADE WEATHER TIGHT IN A

SINGLE WORK DAY. BUILDING

INTERIOR MUST BE PROTECTED FROM

INCLEMENT WEATHER AT THE END OF

EACH WORK DAY.

8. PROTECT SECTIONS OF THE ROOF

THAT HAVE ALREADY BEEN INSTALLED,

ARE EXISTING TO REMAIN OR ARE NOT

IN CONTRACT FROM DAMAGE. DO NOT

USE THE ROOF FOR A STAGING AREA

UNLESS ADEQUATE FACTORY MUTUAL

APPROVED PROTECTION MEASURES

ARE USED TO PROTECT THE ROOF

INSTALLATION.

9. COORDINATE INSTALLATION OF

ROOFING MEMBRANE WITH EXISTING

MECHANICAL EQUIPMENT.

10. REMOVE EXISTING ROOFTOP VENTS

AND OTHER ITEMS ONLY AS

NECESSARY TO INSTALL NEW

FLASHINGS AND ROOF MEMBRANE.

11. VERIFY ALL EXISTING ROOF

DIMENSIONS, WIDTHS & HEIGHTS OF

METAL EDGING CONDITIONS PRIOR TO

BID.

12. PROVIDE NEW METAL FLASHINGS AT

ALL PENETRATIONS AND PERIMETERS.

13. INSTALL NEW GUTTERS TO

ACCOMMODATE EXISTING

DOWNSPOUT LOCATIONS

EXISTING SHINGLE UPPER ROOF

& GUTTERS TO REMAIN, N.I.C.

DEMOLISH EXIST. GUTTER TYP.

DOWNSPOUTS TO REMAIN

DEMOLISH EXIST.

GRAVEL STOP, TYP.

EXIST. EXAUST HOOD, CURBS,

AND VENT TO REMAIN,

DEMOLISH EXIST. METAL

FLASHINGS, TYP.

EXISTING SHINGLE

UPPER ROOF &

GUTTERS TO

REMAIN, N.I.C.

DEMOLISH EXIST. EPDM ROOF

MEMBRANE SYSTEM &

INSULATION COMPLETE, TYP.

58'-1" V.I.F.

EXIST. EQUIPMENT TO REMAN,

PROTECT DURING CONSTRUCTION

OR COORDINATE TEMPORARY

REMOVAL W/ OWNER

DEMOLISH EXIST.

GUTTER AT EPDM

ROOF ABOVE

LEVEL 2, TYP.

DOWNSPOUTS TO

REMAIN

EXISTING SHINGLE

LOWER ROOF &

GUTTERS TO

REMAIN, N.I.C.

AD101

A1

AD101

R1

AD101

M7

AD101 R13

AD101G1

AD101M13 AD101M1

AD101 G7

EXISTING LOWER

EPDM ROOF, N.I.C.

/2

CONTRACTOR TO IDENTIFY

DEFICIENT PLYWOOD ROOF

SHEATHING, REPLACE PANELS

THAT EXHIBIT SWELLING,

BIOLOGICAL GROWTH OR

MOISTURE LEVELS ABOVE 19%

V .I

.F

AD101

G13

E X

IS

T

S

T R

U C

T

AD101

R7

# NUMBER

ACM ALUMINUM COMPOSITE METAL

PANEL

ACP ACOUSTICAL CEILING PANEL

AFF ABOVE FINISH FLOOR

ALUM ALUMINUM

ANOD ANODIZED

AWP ACOUSTIC WALL PANEL

BAS BUILDING AUTOMATION SYSTEM

BC BOTTOM OF CURB

BM BENCH MARK

BOC BACK OF CURB

BOS BOTTOM OF STEEL

BOW BOTTOM OF WALL

BR BUMPER GUARD/BUMPER RAIL

BRG BEARING

BS BOTTOM OF STAIR

C CHANNEL

CC CUBICLE CURTAIN

CFCI CONTRACTOR FURNISHED

CONTRACTOR INSTALLED

CG CORNER GUARD

CIP CAST-IN-PLACE

CJ CONTROL JOINT

CK CORK FLOORING

CL CENTER LINE

CLG CEILING

CLL CONSTRUCTION LIMITS LINE

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

CONC CONCRETE

CONT CONTINUOUS

CPT CARPET

CRK CORK

DEMO DEMOLISH / DEMOLITION

DF DRINKING FOUNTAIN

DIA DIAMETER

DN DOWN

DS DOWNSPOUT

EC ELECTRICAL CONTRACTOR

EIFS EXTERIOR INSULATION FINISH

SYSTEM

EJ EXPANSION JOINT

ELEC ELECTRICAL

ELEV ELEVATION

EPF EPOXY FLOORING

EPT EPOXY PAINT

EQ EQUAL

EWC ELECTRIC WATER COOLER

EX EXISTING

FAF FLUID APPLIED FLOORING

FD FLOOR DRAIN

FF FACTORY FINISH

FFE FINISHED FLOOR ELEVATION

FOC FACE OF CURB

FOF FACE OF FINISH

FOG FACE OF GLAZING

FRP FIBER REINFORCED PANEL

GA GAUGE

GALV GALVANIZED

GC GENERAL CONTRACTOR

GHM GALVANIZED HOLLOW METAL

GL GLASS

GT GROUT

GWB GYPSUM WALL BOARD

GYP GYPSUM

HORZ HORIZONTAL

HM HOLLOW METAL

HT HEIGHT

HVAC HEATING/VENTING/AIR

CONDITIONING

ID INSIDE DIAMETER

L ANGLE

LB/LBS POUND / POUNDS

LVT LUXURY VINYL TILE

MAX MAXIMUM

MB MARKERBOARD

MC MECHANICAL CONTRACTOR

MDF MEDIUM DENSITY FIBERBOARD

MFR MANUFACTURERS

MH MANHOLE

MIL MIL THICKNESS

MIN MINIMUM

MO MASONRY OPENING

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OC ON CENTER

OA OVERALL

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED CONTRACTOR

INSTALLED

OFOI OWNER FURNISHED OWNER

INSTALLED

OH OVERHEAD

ORD OVERFLOW ROOF DRAIN

OTS OPEN TO STRUCTURE

PCT PORCELAIN CERAMIC TILE

PL PLATE

PLAM PLASTIC LAMINATE

PP POLYMER PANEL

PVC POLY VINYL CHLORIDE

PT PAINT

QT QUARTZ

RAD RADIUS

RAF RESILIENT ATHLETIC FLOORING

RB RESILIENT BASE

RD ROOF DRAIN

REX RESIN

REV REVISION

RO ROUGH OPENING

ROW RIGHT-OF-WAY

RSF RESILIENT SHEET FLOORING

RST RESILIENT STAIR TREAD

RTF RESILIENT TILE FLOORING

RUB RUBBER

SC SEALED CONCRETE

SF SQUARE FEET

SIM SIMILAR

SS SOLID SURFACE

STN STONE

ST STL STAINLESS STEEL

SUSP SUSPENDED

T TILE

T&G TONGUE AND GROOVE

TG TEMPERED GLASS

TOC TOP OF CURB

TOM TOP OF MASONRY

TOS TOP OF SLAB / TOP OF STEEL

TOW TOP OF WALL

TP TOILET PARTITION

TPF TACKABLE PANEL FABRIC

TRZ TERRAZZO

TS TOP OF STAIR

TYP TYPICAL

UL UNDERWRITERS LABORATORIES,

INC.

UNO UNLESS NOTED OTHERWISE

VERT VERTICAL

VIF VERIFY IN FIELD

WB WALL BASE

WC WALL COVERING

W/ WITH

W/O WITHOUT

WD WOOD

WGH WALLGUARD HANDRAIL

WM WALK-OFF MAT

WP WALL PROTECTION

WT WINDOW TREATMENT

WWF WELDED WIRE FABRIC

STANDARD ABBREVIATIONSSTANDARD SYMBOLS

VIEW TITLE

DRAWING NUMBER

DRAWING TITLE

DRAWING SCALE

SECTION REFERENCE

DARKENED AREA

DENOTES DIRECTION OF

SECTION CUT

SECTION NUMBER

SHEET NUMBER

ELEVATION REFERENCE

DARKENED AREA

DENOTES ELEVATION

DRAWN

ELEVATION NUMBER

SHEET NUMBER

A201

PLAN DETAIL REFERENCE

DETAIL NUMBER

SHEET NUMBER

DRAWING REVISION

REVISION

REFERENCE

NUMBER

ROOF/FLOOR IDENTIFICATION

NORTH DIRECTION

REFERENCE

DETAIL REFERENCE

A321

XXX

1/8" = 1'-0" X

DETAIL NUMBER

SHEET NUMBER

ITC

SIM/OPP TAG

A101

SIM

A101

SIM

R1

ROOF/FLOOR TYPE

SIM/OPP TAG

BLOCKING - CONTINUOUS BLOCKING - DISCONTINUOUS

RIGID INSULATION PLYWOOD

GYPSUM BOARDBRICK CONCRETE

WOODSPRAY FOAM

INSULATION

SEMI-RIGID

INSULATION

STEEL

ALUMINUM

ROOF LEGEND

EXISTING SHINGLE ROOF,

N.I.C.

EXISTING EPDM ROOF TO

BE DEMO'ED

EXISTING EPDM ROOF TO

REMAIN, N.I.C.

NEW EPDM ROOF

BOX OUT AREA BELOW SOFFIT, TYP.

REMOVE AND PROVIDE NEW

GUTTER TO MATCH EXISTING FINISH

& CONFIGURATION, TYP. ATTACH TO

EXISTING DOWNSPOUTS.

CONTRACTOR TO VERIFY QUANTITY

& LOCATIONS PRIOR TO BID.

G7

A101

EXIST. ASPHALT SHINGLES TO REMAIN

EXISTING FASCIA TO REMAIN.

A1

A101

EXIST. SHINGLE ROOF TO REMAIN

BOX OUT UNDER SOFFIT

G14

A101

G1

A101

EXIST. DOWNSPOUT EXTENSION

OFF SHINGLE ROOF TO REMAIN.

(SALVAGE AND REINSTALL)

EXIST. GUTTER ON SHINGLE

ROOF TO REMAIN, N.I.C.

(REMOVE AND REINSTALL AS

NECESSARY TO INSTALL NEW

FLASHING)

EXISTING DOWNSPOUTS TO

REMAIN, TYP.

SINGLE STORY ROOF, N.I.C.

REMOVE AND PROVIDE NEW GUTTER

TO MATCH EXISTING FINISH &

CONFIGURATION, TYP.

ATTACH TO EXISTING DOWNSPOUTS.

CONTRACTOR TO VERIFY QUANTITY &

LOCATIONS PRIOR TO BID.

EXISTING FASICA AND FASCIA

EXTENSION TO REMAIN

BOX OUT UNDER SOFFIT

DEMO EXISTING SOFFIT AND FASCIA AT BOX OUT

EXIST. ASPHALT SHINGLES TO REMAIN

EXIST. METAL DRIP EDGE TO REMAIN

DEMO EXIST. FLASHING AND FASTENERS,

PROVIDE NEW FLASHING

NEW FLASHING

G7

A101

BOX OUT AREA BELOW SOFFIT, TYP.

REMOVE AND PROVIDE NEW

GUTTER TO MATCH EXISTING FINISH

& CONFIGURATION, TYP. ATTACH TO

EXISTING DOWNSPOUTS.

CONTRACTOR TO VERIFY QUANTITY

& LOCATIONS PRIOR TO BID.

EXIST. ASPHALT SHINGLES TO REMAIN

DEMO EXIST. FLASHING AND FASTENERS,

PROVIDE NEW FLASHING

EXIST. FASCIA TO REMAIN

A7

A101

TERM BAR & SEALANT BEHIND COUNTER

FLASHING

A1

A101

EXIST. SHINGLE ROOF AND

GUTTERS TO REMAIN

G14

A101

G1

A101

FASCIA AND FASCIA EXTENSION TO REMAIN

PROVIDE NEW PREFIN. GRAVEL STOP, TYP.

SHINGLE ROOF TO REMAIN

DEMO EXIST. FLASHING AND

FASTENERS, PROVIDE NEW

FLASHING

DRIP EDGE TO REMAIN

A7

A101

SHINGLE ROOF TO REMAIN

EXIST. EXHAUST HOOD AND VENT TO

REMAIN.

PROVIDE PREFORMED PIPE FLASHING, TYP.

EXIST. EXHAUST HOOD TO REMAIN, PROVIDE

NEW MEMBRANE FLASHING AT CURB.

EXTEND CURB AS NECESSARY TO MAINTAIN

MIN. 8" CURB HEIGHT

EXIST. SHINGLE ROOF AND GUTTERS TO

REMAIN, TYP.

EXIST. EXHAUST HOOD AND VENT TO

REMAIN.

SHINGLE ROOF TO REMAIN, N.I.C.

ROOFING BELOW TO REMAIN, N.I.C.

REMOVE AND PROVIDE NEW GUTTER TO MATCH

EXISTING FINISH & CONFIGURATION, TYP. ATTACH

TO EXISTING DOWNSPOUTS.

CONTRACTOR TO VERIFY QUANTITY & LOCATIONS

PRIOR TO BID.

A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2024 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

SAMUELS GROUP

2929 WESTOWN PARKWAY, SUITE 200

WEST DES MOINES, IA 50266

P. 515-288-0467

Project

Construction Manager

/2

/2

:0

:1

A

M

AD101

DEMO ROOF PLAN AND

EXISTING CONDITIONS

24805001

BID SET 05/22/24

9375.00 - DOC 5JD FT DES MOINES

BLDG 65-66 ROOF REPLACEMENT

STATE OF IOWA - DOC FIFTH JUDICIAL

DISTRICT

68 THAYER ST

DES MOINES, IA 50315

1305 E WALNUT ST

DES MOINES, IA 50319

N

1/8" = 1'-0" A11

DEMO ROOF PLAN

R7

EXISTING ROOF VENTS AND EXPOSED PARTY WALL

12" = 1'-0" M1

WEST GUTTER AND UPPER ROOF CONDITION

12" = 1'-0" G1

EXISTING GUTTER CONDITION

12" = 1'-0" R13

EXISTING ROOF VENTS

12" = 1'-0" M13

SOFFIT CONDITION

12" = 1'-0" R1

EXISTING UPPER SHINGLE ROOF FASCIA

12" = 1'-0" G7

UPPER SHINGLE ROOF GUTTER

12" = 1'-0"

G13

LOWER SHINGLE ROOF

12" = 1'-0" A1

SOUTH ELEVATION

12" = 1'-0" M7

NORTHWEST SOFFIT AND EXISTING SHINGLE ROOF CONDITION

Revision Description Date

THIS DETAIL ILLUSTRATES A TYPICAL

APPLICATION OF CURB FLASHINGS

ONLY. BASE / CORNER FLASHINGS

AND TERMINATIONS NOT SHOWN FOR

CLARITY (PROVIDE PER ROOFING

MFR. INSTRUCTIONS).

EXIST. SEE RELATED SECTION DETAIL

THIS SHEET FOR TERMINATION BAR

INSTALLATION.

EXISTING CURB.

EXTEND CURB AS NECESSARY TO

MAINTAIN 8" MIN. CURB HEIGHT

NEW ROOF MEMBRANE

OVERLAP MEMBRANE FLASHING

AND ROOF MEMBRANE 4"

MINIMUM FOR PROPER SEAMING

HOT DIPPED GALVANIZED NAILS

1-1/4" (31.75 mm) LENGTH AT 6" (152.4 mm) OC MAX.

NEW MEMBRANE FLASHING, TYP.

PRE-MOLDED PIPE SEAL

WATER CUT-OFF MASTIC

EXISTING PIPE OR VENT

M

IN

4"

ST. STL. CLAMP RING

FOAMED-IN-PLACE SPRAY

ON INSULATION AT

PENETRATIONS.

EXIST. PLYWOOD

DECKING

SEE ROOF PLAN FOR ROOF

TYPE

CONT. WELD BASE OF

PIPE FLASHING

EXIST. ROOF DECK TO REMAIN

EXIST. WOOD BLOCKING TO REMAIN

TURN ROOF MEMBRANE

DOWN FACE OF WALL

WOOD BLOCKING AS REQ'D.

SEE ROOF PLAN FOR ROOF TYPE

PREFIN. GRAVEL STOP

EXIST. FASCIA TO REMAIN

CONTINUOUS CLEAT

CONT. SEALANT, TYP.

EXIST. ROOF DECK TO REMAIN

REMOVE AND PROVIDE NEW GUTTER TO MATCH

EXISTING FINISH & CONFIGURATION, TYP.

ATTACH TO EXISTING DOWNSPOUTS.

EXIST. WOOD BLOCKING TO REMAIN

EXIST. FASCIA TO REMAIN

TURN ROOF MEMBRANE DOWN FACE OF WALL

WOOD BLOCKING AS REQ'D.

SEE ROOF PLAN FOR ROOF TYPE

6"

ROOF MEMBRANE FLASHING

PREFIN. METAL DRIP EDGE W/ CONT. CLEAT

EXIST. ASPHALT SHINGLES TO REMAIN

EXIST. PLYWOOD DECKING TO REMAIN

WOOD BLOCKING AS REQ'D

ROOF MEMBRANE FLASHING

TURN ROOF MEMBRANE DOWN SLOPE

PREFIN. METAL FLASHING (NO JOINTS)

CONT. CLEAT

EXISTING

WALL / CURB

EXIST. ASPHALT SHINGLES TO REMAIN

M

IN

SEE ROOF PLAN FOR ROOF TYPE

EXIST. PLYWOOD DECKING

NEW 3/4" PLYWOOD BOX OUT UNDER SOFFIT

WOOD BLOCKING AS REQ'D

DRIP EDGE BEYOND

EXIST. METAL DRIP EDGE TO REMAIN

PROVIDE NEW FLASHING

NEW PREFIN. METAL COUNTER FLASHING. ALIGN

W/ COUNTER FLASHING AT ADJACENT ROOF EDGE

TERM. BAR W/ SEALANT

CONT. CLEAT W/ SEALANT, TYP.

PROVIDE ROOF INSULATION IN BOX OUT

CAVITIES, TYP.

EXIST. ASPHALT SHINGLES TO REMAIN

EXIST. METAL DRIP EDGE TO REMAIN

PROVIDE NEW FLASHING

EXIST. PLYWOOD DECKING

EXIST. WOOD BLOCKING

SEE ROOF PLAN FOR ROOF TYPE

EXISTING

WALL / CURB

M

IN

PROVIDE MIN. 1-1/2" CONT. WELD

NEW PREFIN. METAL COUNTER FLASHING,

TUCK UP UNDER EXISTING FLASHING

TERM. BAR W/ SEALANT

CONT. CLEAT W/ SEALANT, TYP.

EXISTING SHINGLE UPPER ROOF

& GUTTERS TO REMAIN, N.I.C.A7

A101

G7

A101

A1

A101

G14

A101

EXISTING SHINGLE

LOWER ROOF &

GUTTERS TO

REMAIN, N.I.C.

G1

A101

G1

A101

EXISTING LOWER

EPDM ROOF, N.I.C.

/2

A1

A101 SIM

SIM

EXIST. EXAUST HOOD, CURBS,

AND VENT TO REMAIN.

SALVAGE EXHAUST HOOD FOR

REINSTALLATION

NEW GUTTERS, TYP.

THIS ROOF

L1

A101

A101

L7

E X

IS

T

S

T R

U C

T

ROOF TYPE R-1

ROOF TYPES LEGEND

R-1 SINGLE-PLY MEMBRANE

- 60 MIL EPDM ROOF MEMBRANE

FULLY ADHERED TO COVERBOARD

- 1/2" HIGH DENSITY

POLYISOCYANURATE COVERBOARD

- (2) LAYERS 2.5" POLYISOCYANURATE

RIGID ROOF INSULATION - MIN R30

- VAPOR BARRIER

- EXISTING PLYWOOD ROOF DECK

NOTE:

CONTRACTOR TO VERIFY

CONDITION OF EXISTING ROOF

DECKING. REPLACE PANELS

EXHIBITING SWELLING, BIOLOGICAL

GROWTH, OR HIGH MOISTURE

CONTENT (ABOVE 19%)

N

1/8" = 1'-0" A17

ROOF PLAN

A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2024 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

SAMUELS GROUP

2929 WESTOWN PARKWAY, SUITE 200

WEST DES MOINES, IA 50266

P. 515-288-0467

Project

Construction Manager

/2

/2

:0

:1

A

M

A101

ROOF PLAN AND DETAILS

24805001

BID SET 05/22/24

9375.00 - DOC 5JD FT DES MOINES

BLDG 65-66 ROOF REPLACEMENT

STATE OF IOWA - DOC FIFTH JUDICIAL

DISTRICT

68 THAYER ST

DES MOINES, IA 50315

1305 E WALNUT ST

DES MOINES, IA 50319

6" = 1'-0" L7

FLASHING APPLICATION ILLUSTRATION

1 1/2" = 1'-0"

L1

SECTION DETAIL - VENT PIPE BOOT FLASHING

1 1/2" = 1'-0" G1

SECTION DETAIL - GRAVEL STOP

1 1/2" = 1'-0"

G7

SECTION DETAIL - GUTTER

1 1/2" = 1'-0" G14

SECTION DETAIL - MEMBRANE TO SHINGLE

1 1/2" = 1'-0" A1

SECTION DETAIL - SHINGLE ROOF EAVE BOX OUT

1 1/2" = 1'-0"

A7

SECTION DETAIL - SHINGLE ROOF / WALL / CURB FLASHING

Revision Description Date

Sheets
A101 - ROOF PLAN AND DETAILS
AD101 - DEMO ROOF PLAN AND EXISTING CONDITIONS
G000 - COVER SHEET

File details come from the government source that posted it. Updated .