RFB937500-01 - Drawing Details.pdf
PDF 1 MB Posted
- Attached to
- 5JD DM Bldgs 65-66 Renovations
- Solicitation number
- RFB937500-01
- Issued by
- Polk County, Des Moines City, Iowa
About this file
This document contains architectural drawings and specifications for the Roof Replacement for Buildings 65-66 at 5JD Ft Des Moines in Des Moines, Iowa. The project is being managed by the Iowa Department of Administrative Services, with OPN Architects as the architect and Samuels Group as the construction manager. The scope of work includes demolishing the existing EPDM roof membrane system and insulation, and installing a new 60 mil EPDM roof membrane system with new polyisocyanurate insulation to meet a minimum R-30 value. The contractor is required to identify and replace any deficient plywood roof sheathing. The project must be completed while the facility remains in operation, with coordination required to minimize interference with daily operations. Bids are being solicited under Reference # 005-RFBCON-1124-2024 on the IMPACS system, with a bid set due date of May 22, 2024.
The pricing terms are not specified in the documentation provided. The project is funded by the State of Iowa, but the specific funding sources and amounts are not detailed. There are no indications of any set-aside requirements or incumbent contractors. The contract term and any renewal options are also not provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFB937500-01 - Project Manual.pdf | ||
| RFB937500-01 - Notice to Bidders.pdf | ||
| RFB937500-01 - Bid Form.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT
LOCATION
PROJECT
LOCATION
N
100 Court Ave. Suite 100, Des Moines, IA 50309
P: 515-309-0722 F: 515-309-0725 www.opnarchitects.com
ARCHITECT
OPN ARCHITECTS
100 COURT AVENUE
DES MOINES, IA 50309
SAMUELS GROUP
2929 WESTOWN PARKWAY, SUITE 200
WEST DES MOINES, IA 50266
CONSTRUCTION MANAGER
9375.00 - DOC 5JD FT DES MOINES BLDG 65-66 ROOF
REPLACEMENT
68 THAYER ST, DES MOINES, IA 50315
B
ID
S E
T
All questions regarding these plans and specifications should be directed to:
NATE STIELER, AIA
Project Manager nstieler@opnarchitects.com 515-309-6882
ARCHITECTURAL DRAWINGS
SHEET
NUMBER SHEET NAME
G000 COVER SHEET
AD101 DEMO ROOF PLAN AND EXISTING CONDITIONS
A101 ROOF PLAN AND DETAILS
SITE LOCATION
GENERAL NOTES
1. DIMENSIONS ARE MEASURED FACE-
OF-FINISH TO FACE-OF-FINISH OR
ROUGH MASONRY OPENING UNLESS
NOTED OTHERWISE - TYPICAL FOR ALL
DRAWINGS.
2. FIELD VERIFY ALL DIMENSIONS AND
EXISTING CONDITIONS - TYPICAL FOR
ALL DRAWINGS.
3. IN THE EVENT OF A DISCREPANCY
BETWEEN ARCHITECTURAL AND
CONSULTANT DRAWINGS, NOTIFY
ARCHITECT IMMEDIATELY PRIOR TO
COMMENCING WORK - TYPICAL FOR
ALL DRAWINGS.
4. THIS FACILITY WILL REMAIN IN
OPERATION THROUGHOUT THE
DURATION OF THE PROJECT.
COORDINATE ALL ROOFING ACTIVITIES
WITH THE OWNER TO MINIMIZE
INTERFERENCE OF DAILY
OPERATIONS.
5. CONTRACTOR TO IDENTIFY AND
REPLACE DEFICIENT PLYWOOD ROOF
SHEATHING, REPLACE PANELS THAT
EXHIBIT SWELLING, BIOLOGICAL
GROWTH OR MOISTURE LEVELS
ABOVE 19%. CONFIRM LOCATIONS W/
ARCHITECT PRIOR TO REPLACING.
6. VERIFY LOCATIONS OF ALL ROOF
PENETRATIONS. PROVIDE BOOTS,
FLASHING AND OTHER ACCESSORIES
REQUIRED TO PROVIDE A COMPLETE,
WATERTIGHT WARRANTED SYSTEM.
7. REPLACE ONLY THE AMOUNT OF
ROOFING THAT CAN BE COMPLETED
AND MADE WEATHER TIGHT IN A
SINGLE WORK DAY. BUILDING
INTERIOR MUST BE PROTECTED FROM
INCLEMENT WEATHER AT THE END OF
EACH WORK DAY.
8. PROTECT SECTIONS OF THE ROOF
THAT HAVE ALREADY BEEN INSTALLED,
ARE EXISTING TO REMAIN OR ARE NOT
IN CONTRACT FROM DAMAGE. DO NOT
USE THE ROOF FOR A STAGING AREA
UNLESS ADEQUATE FACTORY MUTUAL
APPROVED PROTECTION MEASURES
ARE USED TO PROTECT THE ROOF
INSTALLATION.
9. COORDINATE INSTALLATION OF
ROOFING MEMBRANE WITH EXISTING
MECHANICAL EQUIPMENT.
10. REMOVE EXISTING ROOFTOP VENTS
AND OTHER ITEMS ONLY AS
NECESSARY TO INSTALL NEW
FLASHINGS AND ROOF MEMBRANE.
11. VERIFY ALL EXISTING ROOF
DIMENSIONS, WIDTHS & HEIGHTS OF
METAL EDGING CONDITIONS PRIOR TO
BID.
12. PROVIDE NEW METAL FLASHINGS AT
ALL PENETRATIONS AND PERIMETERS.
13. INSTALL NEW GUTTERS TO
ACCOMMODATE EXISTING
DOWNSPOUT LOCATIONS
EXISTING SHINGLE UPPER ROOF
& GUTTERS TO REMAIN, N.I.C.
DEMOLISH EXIST. GUTTER TYP.
DOWNSPOUTS TO REMAIN
DEMOLISH EXIST.
GRAVEL STOP, TYP.
EXIST. EXAUST HOOD, CURBS,
AND VENT TO REMAIN,
DEMOLISH EXIST. METAL
FLASHINGS, TYP.
EXISTING SHINGLE
UPPER ROOF &
GUTTERS TO
REMAIN, N.I.C.
DEMOLISH EXIST. EPDM ROOF
MEMBRANE SYSTEM &
INSULATION COMPLETE, TYP.
58'-1" V.I.F.
EXIST. EQUIPMENT TO REMAN,
PROTECT DURING CONSTRUCTION
OR COORDINATE TEMPORARY
REMOVAL W/ OWNER
DEMOLISH EXIST.
GUTTER AT EPDM
ROOF ABOVE
LEVEL 2, TYP.
DOWNSPOUTS TO
REMAIN
EXISTING SHINGLE
LOWER ROOF &
GUTTERS TO
REMAIN, N.I.C.
AD101
A1
AD101
R1
AD101
M7
AD101 R13
AD101G1
AD101M13 AD101M1
AD101 G7
EXISTING LOWER
EPDM ROOF, N.I.C.
/2
CONTRACTOR TO IDENTIFY
DEFICIENT PLYWOOD ROOF
SHEATHING, REPLACE PANELS
THAT EXHIBIT SWELLING,
BIOLOGICAL GROWTH OR
MOISTURE LEVELS ABOVE 19%
V .I
.F
AD101
G13
E X
IS
T
S
T R
U C
T
AD101
R7
# NUMBER
ACM ALUMINUM COMPOSITE METAL
PANEL
ACP ACOUSTICAL CEILING PANEL
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
ANOD ANODIZED
AWP ACOUSTIC WALL PANEL
BAS BUILDING AUTOMATION SYSTEM
BC BOTTOM OF CURB
BM BENCH MARK
BOC BACK OF CURB
BOS BOTTOM OF STEEL
BOW BOTTOM OF WALL
BR BUMPER GUARD/BUMPER RAIL
BRG BEARING
BS BOTTOM OF STAIR
C CHANNEL
CC CUBICLE CURTAIN
CFCI CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
CG CORNER GUARD
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CK CORK FLOORING
CL CENTER LINE
CLG CEILING
CLL CONSTRUCTION LIMITS LINE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
CONC CONCRETE
CONT CONTINUOUS
CPT CARPET
CRK CORK
DEMO DEMOLISH / DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DN DOWN
DS DOWNSPOUT
EC ELECTRICAL CONTRACTOR
EIFS EXTERIOR INSULATION FINISH
SYSTEM
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATION
EPF EPOXY FLOORING
EPT EPOXY PAINT
EQ EQUAL
EWC ELECTRIC WATER COOLER
EX EXISTING
FAF FLUID APPLIED FLOORING
FD FLOOR DRAIN
FF FACTORY FINISH
FFE FINISHED FLOOR ELEVATION
FOC FACE OF CURB
FOF FACE OF FINISH
FOG FACE OF GLAZING
FRP FIBER REINFORCED PANEL
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GHM GALVANIZED HOLLOW METAL
GL GLASS
GT GROUT
GWB GYPSUM WALL BOARD
GYP GYPSUM
HORZ HORIZONTAL
HM HOLLOW METAL
HT HEIGHT
HVAC HEATING/VENTING/AIR
CONDITIONING
ID INSIDE DIAMETER
L ANGLE
LB/LBS POUND / POUNDS
LVT LUXURY VINYL TILE
MAX MAXIMUM
MB MARKERBOARD
MC MECHANICAL CONTRACTOR
MDF MEDIUM DENSITY FIBERBOARD
MFR MANUFACTURERS
MH MANHOLE
MIL MIL THICKNESS
MIN MINIMUM
MO MASONRY OPENING
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OA OVERALL
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR
INSTALLED
OFOI OWNER FURNISHED OWNER
INSTALLED
OH OVERHEAD
ORD OVERFLOW ROOF DRAIN
OTS OPEN TO STRUCTURE
PCT PORCELAIN CERAMIC TILE
PL PLATE
PLAM PLASTIC LAMINATE
PP POLYMER PANEL
PVC POLY VINYL CHLORIDE
PT PAINT
QT QUARTZ
RAD RADIUS
RAF RESILIENT ATHLETIC FLOORING
RB RESILIENT BASE
RD ROOF DRAIN
REX RESIN
REV REVISION
RO ROUGH OPENING
ROW RIGHT-OF-WAY
RSF RESILIENT SHEET FLOORING
RST RESILIENT STAIR TREAD
RTF RESILIENT TILE FLOORING
RUB RUBBER
SC SEALED CONCRETE
SF SQUARE FEET
SIM SIMILAR
SS SOLID SURFACE
STN STONE
ST STL STAINLESS STEEL
SUSP SUSPENDED
T TILE
T&G TONGUE AND GROOVE
TG TEMPERED GLASS
TOC TOP OF CURB
TOM TOP OF MASONRY
TOS TOP OF SLAB / TOP OF STEEL
TOW TOP OF WALL
TP TOILET PARTITION
TPF TACKABLE PANEL FABRIC
TRZ TERRAZZO
TS TOP OF STAIR
TYP TYPICAL
UL UNDERWRITERS LABORATORIES,
INC.
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
WB WALL BASE
WC WALL COVERING
W/ WITH
W/O WITHOUT
WD WOOD
WGH WALLGUARD HANDRAIL
WM WALK-OFF MAT
WP WALL PROTECTION
WT WINDOW TREATMENT
WWF WELDED WIRE FABRIC
STANDARD ABBREVIATIONSSTANDARD SYMBOLS
VIEW TITLE
DRAWING NUMBER
DRAWING TITLE
DRAWING SCALE
SECTION REFERENCE
DARKENED AREA
DENOTES DIRECTION OF
SECTION CUT
SECTION NUMBER
SHEET NUMBER
ELEVATION REFERENCE
DARKENED AREA
DENOTES ELEVATION
DRAWN
ELEVATION NUMBER
SHEET NUMBER
A201
PLAN DETAIL REFERENCE
DETAIL NUMBER
SHEET NUMBER
DRAWING REVISION
REVISION
REFERENCE
NUMBER
ROOF/FLOOR IDENTIFICATION
NORTH DIRECTION
REFERENCE
DETAIL REFERENCE
A321
XXX
1/8" = 1'-0" X
DETAIL NUMBER
SHEET NUMBER
ITC
SIM/OPP TAG
A101
SIM
A101
SIM
R1
ROOF/FLOOR TYPE
SIM/OPP TAG
BLOCKING - CONTINUOUS BLOCKING - DISCONTINUOUS
RIGID INSULATION PLYWOOD
GYPSUM BOARDBRICK CONCRETE
WOODSPRAY FOAM
INSULATION
SEMI-RIGID
INSULATION
STEEL
ALUMINUM
ROOF LEGEND
EXISTING SHINGLE ROOF,
N.I.C.
EXISTING EPDM ROOF TO
BE DEMO'ED
EXISTING EPDM ROOF TO
REMAIN, N.I.C.
NEW EPDM ROOF
BOX OUT AREA BELOW SOFFIT, TYP.
REMOVE AND PROVIDE NEW
GUTTER TO MATCH EXISTING FINISH
& CONFIGURATION, TYP. ATTACH TO
EXISTING DOWNSPOUTS.
CONTRACTOR TO VERIFY QUANTITY
& LOCATIONS PRIOR TO BID.
G7
A101
EXIST. ASPHALT SHINGLES TO REMAIN
EXISTING FASCIA TO REMAIN.
A1
A101
EXIST. SHINGLE ROOF TO REMAIN
BOX OUT UNDER SOFFIT
G14
A101
G1
A101
EXIST. DOWNSPOUT EXTENSION
OFF SHINGLE ROOF TO REMAIN.
(SALVAGE AND REINSTALL)
EXIST. GUTTER ON SHINGLE
ROOF TO REMAIN, N.I.C.
(REMOVE AND REINSTALL AS
NECESSARY TO INSTALL NEW
FLASHING)
EXISTING DOWNSPOUTS TO
REMAIN, TYP.
SINGLE STORY ROOF, N.I.C.
REMOVE AND PROVIDE NEW GUTTER
TO MATCH EXISTING FINISH &
CONFIGURATION, TYP.
ATTACH TO EXISTING DOWNSPOUTS.
CONTRACTOR TO VERIFY QUANTITY &
LOCATIONS PRIOR TO BID.
EXISTING FASICA AND FASCIA
EXTENSION TO REMAIN
BOX OUT UNDER SOFFIT
DEMO EXISTING SOFFIT AND FASCIA AT BOX OUT
EXIST. ASPHALT SHINGLES TO REMAIN
EXIST. METAL DRIP EDGE TO REMAIN
DEMO EXIST. FLASHING AND FASTENERS,
PROVIDE NEW FLASHING
NEW FLASHING
G7
A101
BOX OUT AREA BELOW SOFFIT, TYP.
REMOVE AND PROVIDE NEW
GUTTER TO MATCH EXISTING FINISH
& CONFIGURATION, TYP. ATTACH TO
EXISTING DOWNSPOUTS.
CONTRACTOR TO VERIFY QUANTITY
& LOCATIONS PRIOR TO BID.
EXIST. ASPHALT SHINGLES TO REMAIN
DEMO EXIST. FLASHING AND FASTENERS,
PROVIDE NEW FLASHING
EXIST. FASCIA TO REMAIN
A7
A101
TERM BAR & SEALANT BEHIND COUNTER
FLASHING
A1
A101
EXIST. SHINGLE ROOF AND
GUTTERS TO REMAIN
G14
A101
G1
A101
FASCIA AND FASCIA EXTENSION TO REMAIN
PROVIDE NEW PREFIN. GRAVEL STOP, TYP.
SHINGLE ROOF TO REMAIN
DEMO EXIST. FLASHING AND
FASTENERS, PROVIDE NEW
FLASHING
DRIP EDGE TO REMAIN
A7
A101
SHINGLE ROOF TO REMAIN
EXIST. EXHAUST HOOD AND VENT TO
REMAIN.
PROVIDE PREFORMED PIPE FLASHING, TYP.
EXIST. EXHAUST HOOD TO REMAIN, PROVIDE
NEW MEMBRANE FLASHING AT CURB.
EXTEND CURB AS NECESSARY TO MAINTAIN
MIN. 8" CURB HEIGHT
EXIST. SHINGLE ROOF AND GUTTERS TO
REMAIN, TYP.
EXIST. EXHAUST HOOD AND VENT TO
REMAIN.
SHINGLE ROOF TO REMAIN, N.I.C.
ROOFING BELOW TO REMAIN, N.I.C.
REMOVE AND PROVIDE NEW GUTTER TO MATCH
EXISTING FINISH & CONFIGURATION, TYP. ATTACH
TO EXISTING DOWNSPOUTS.
CONTRACTOR TO VERIFY QUANTITY & LOCATIONS
PRIOR TO BID.
A
19181716151413121110987654
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
P R
IN
T
E D
R
S
T
U
20 21 22 23 24 25
Sheet Name
Key Plan
19181716151413121110987654 20 21 22 23 24 25321
Sheet Number
Sheet Issue Date
OPN Project No.
Owner
All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by
OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.
shall retain all common law, statutory and other reserved rights, including the copyright thereto.
© 2024 OPN Architects, Inc.
100 Court Ave., Suite 100
Des Moines, IA 50309
P: 515-309-0722 www.opnarchitects.com
SAMUELS GROUP
2929 WESTOWN PARKWAY, SUITE 200
WEST DES MOINES, IA 50266
P. 515-288-0467
Project
Construction Manager
/2
/2
:0
:1
A
M
AD101
DEMO ROOF PLAN AND
EXISTING CONDITIONS
24805001
BID SET 05/22/24
9375.00 - DOC 5JD FT DES MOINES
BLDG 65-66 ROOF REPLACEMENT
STATE OF IOWA - DOC FIFTH JUDICIAL
DISTRICT
68 THAYER ST
DES MOINES, IA 50315
1305 E WALNUT ST
DES MOINES, IA 50319
N
1/8" = 1'-0" A11
DEMO ROOF PLAN
R7
EXISTING ROOF VENTS AND EXPOSED PARTY WALL
12" = 1'-0" M1
WEST GUTTER AND UPPER ROOF CONDITION
12" = 1'-0" G1
EXISTING GUTTER CONDITION
12" = 1'-0" R13
EXISTING ROOF VENTS
12" = 1'-0" M13
SOFFIT CONDITION
12" = 1'-0" R1
EXISTING UPPER SHINGLE ROOF FASCIA
12" = 1'-0" G7
UPPER SHINGLE ROOF GUTTER
12" = 1'-0"
G13
LOWER SHINGLE ROOF
12" = 1'-0" A1
SOUTH ELEVATION
12" = 1'-0" M7
NORTHWEST SOFFIT AND EXISTING SHINGLE ROOF CONDITION
Revision Description Date
THIS DETAIL ILLUSTRATES A TYPICAL
APPLICATION OF CURB FLASHINGS
ONLY. BASE / CORNER FLASHINGS
AND TERMINATIONS NOT SHOWN FOR
CLARITY (PROVIDE PER ROOFING
MFR. INSTRUCTIONS).
EXIST. SEE RELATED SECTION DETAIL
THIS SHEET FOR TERMINATION BAR
INSTALLATION.
EXISTING CURB.
EXTEND CURB AS NECESSARY TO
MAINTAIN 8" MIN. CURB HEIGHT
NEW ROOF MEMBRANE
OVERLAP MEMBRANE FLASHING
AND ROOF MEMBRANE 4"
MINIMUM FOR PROPER SEAMING
HOT DIPPED GALVANIZED NAILS
1-1/4" (31.75 mm) LENGTH AT 6" (152.4 mm) OC MAX.
NEW MEMBRANE FLASHING, TYP.
PRE-MOLDED PIPE SEAL
WATER CUT-OFF MASTIC
EXISTING PIPE OR VENT
M
IN
4"
ST. STL. CLAMP RING
FOAMED-IN-PLACE SPRAY
ON INSULATION AT
PENETRATIONS.
EXIST. PLYWOOD
DECKING
SEE ROOF PLAN FOR ROOF
TYPE
CONT. WELD BASE OF
PIPE FLASHING
EXIST. ROOF DECK TO REMAIN
EXIST. WOOD BLOCKING TO REMAIN
TURN ROOF MEMBRANE
DOWN FACE OF WALL
WOOD BLOCKING AS REQ'D.
SEE ROOF PLAN FOR ROOF TYPE
PREFIN. GRAVEL STOP
EXIST. FASCIA TO REMAIN
CONTINUOUS CLEAT
CONT. SEALANT, TYP.
EXIST. ROOF DECK TO REMAIN
REMOVE AND PROVIDE NEW GUTTER TO MATCH
EXISTING FINISH & CONFIGURATION, TYP.
ATTACH TO EXISTING DOWNSPOUTS.
EXIST. WOOD BLOCKING TO REMAIN
EXIST. FASCIA TO REMAIN
TURN ROOF MEMBRANE DOWN FACE OF WALL
WOOD BLOCKING AS REQ'D.
SEE ROOF PLAN FOR ROOF TYPE
6"
ROOF MEMBRANE FLASHING
PREFIN. METAL DRIP EDGE W/ CONT. CLEAT
EXIST. ASPHALT SHINGLES TO REMAIN
EXIST. PLYWOOD DECKING TO REMAIN
WOOD BLOCKING AS REQ'D
ROOF MEMBRANE FLASHING
TURN ROOF MEMBRANE DOWN SLOPE
PREFIN. METAL FLASHING (NO JOINTS)
CONT. CLEAT
EXISTING
WALL / CURB
EXIST. ASPHALT SHINGLES TO REMAIN
M
IN
SEE ROOF PLAN FOR ROOF TYPE
EXIST. PLYWOOD DECKING
NEW 3/4" PLYWOOD BOX OUT UNDER SOFFIT
WOOD BLOCKING AS REQ'D
DRIP EDGE BEYOND
EXIST. METAL DRIP EDGE TO REMAIN
PROVIDE NEW FLASHING
NEW PREFIN. METAL COUNTER FLASHING. ALIGN
W/ COUNTER FLASHING AT ADJACENT ROOF EDGE
TERM. BAR W/ SEALANT
CONT. CLEAT W/ SEALANT, TYP.
PROVIDE ROOF INSULATION IN BOX OUT
CAVITIES, TYP.
EXIST. ASPHALT SHINGLES TO REMAIN
EXIST. METAL DRIP EDGE TO REMAIN
PROVIDE NEW FLASHING
EXIST. PLYWOOD DECKING
EXIST. WOOD BLOCKING
SEE ROOF PLAN FOR ROOF TYPE
EXISTING
WALL / CURB
M
IN
PROVIDE MIN. 1-1/2" CONT. WELD
NEW PREFIN. METAL COUNTER FLASHING,
TUCK UP UNDER EXISTING FLASHING
TERM. BAR W/ SEALANT
CONT. CLEAT W/ SEALANT, TYP.
EXISTING SHINGLE UPPER ROOF
& GUTTERS TO REMAIN, N.I.C.A7
A101
G7
A101
A1
A101
G14
A101
EXISTING SHINGLE
LOWER ROOF &
GUTTERS TO
REMAIN, N.I.C.
G1
A101
G1
A101
EXISTING LOWER
EPDM ROOF, N.I.C.
/2
A1
A101 SIM
SIM
EXIST. EXAUST HOOD, CURBS,
AND VENT TO REMAIN.
SALVAGE EXHAUST HOOD FOR
REINSTALLATION
NEW GUTTERS, TYP.
THIS ROOF
L1
A101
A101
L7
E X
IS
T
S
T R
U C
T
ROOF TYPE R-1
ROOF TYPES LEGEND
R-1 SINGLE-PLY MEMBRANE
- 60 MIL EPDM ROOF MEMBRANE
FULLY ADHERED TO COVERBOARD
- 1/2" HIGH DENSITY
POLYISOCYANURATE COVERBOARD
- (2) LAYERS 2.5" POLYISOCYANURATE
RIGID ROOF INSULATION - MIN R30
- VAPOR BARRIER
- EXISTING PLYWOOD ROOF DECK
NOTE:
CONTRACTOR TO VERIFY
CONDITION OF EXISTING ROOF
DECKING. REPLACE PANELS
EXHIBITING SWELLING, BIOLOGICAL
GROWTH, OR HIGH MOISTURE
CONTENT (ABOVE 19%)
N
1/8" = 1'-0" A17
ROOF PLAN
A
19181716151413121110987654
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
P R
IN
T
E D
R
S
T
U
20 21 22 23 24 25
Sheet Name
Key Plan
19181716151413121110987654 20 21 22 23 24 25321
Sheet Number
Sheet Issue Date
OPN Project No.
Owner
All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by
OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.
shall retain all common law, statutory and other reserved rights, including the copyright thereto.
© 2024 OPN Architects, Inc.
100 Court Ave., Suite 100
Des Moines, IA 50309
P: 515-309-0722 www.opnarchitects.com
SAMUELS GROUP
2929 WESTOWN PARKWAY, SUITE 200
WEST DES MOINES, IA 50266
P. 515-288-0467
Project
Construction Manager
/2
/2
:0
:1
A
M
A101
ROOF PLAN AND DETAILS
24805001
BID SET 05/22/24
9375.00 - DOC 5JD FT DES MOINES
BLDG 65-66 ROOF REPLACEMENT
STATE OF IOWA - DOC FIFTH JUDICIAL
DISTRICT
68 THAYER ST
DES MOINES, IA 50315
1305 E WALNUT ST
DES MOINES, IA 50319
6" = 1'-0" L7
FLASHING APPLICATION ILLUSTRATION
1 1/2" = 1'-0"
L1
SECTION DETAIL - VENT PIPE BOOT FLASHING
1 1/2" = 1'-0" G1
SECTION DETAIL - GRAVEL STOP
1 1/2" = 1'-0"
G7
SECTION DETAIL - GUTTER
1 1/2" = 1'-0" G14
SECTION DETAIL - MEMBRANE TO SHINGLE
1 1/2" = 1'-0" A1
SECTION DETAIL - SHINGLE ROOF EAVE BOX OUT
1 1/2" = 1'-0"
A7
SECTION DETAIL - SHINGLE ROOF / WALL / CURB FLASHING
Revision Description Date
| Sheets |
| A101 - ROOF PLAN AND DETAILS |
| AD101 - DEMO ROOF PLAN AND EXISTING CONDITIONS |
| G000 - COVER SHEET |
File details come from the government source that posted it. Updated .