This is an architectural drawing set and code compliance documentation for the Madison County Highway Garage Office Area Renovation project, a construction project overseen by King + King Architects for Madison County, New York. The project involves renovation of the office area within an existing highway garage facility located at 139 North Court Street, Wampsville, New York. The architectural documents include detailed construction drawings issued for construction on July 14, 2026, comprising floor plans, demolition plans, reflected ceiling plans, wall sections, door and window schedules, HVAC plans, and electrical plans. The project is classified as a mixed-use facility with Group B (Business), Group S-1 (Storage, Moderate Hazard), and Group U (Private Garage) occupancies. The existing building maintains an International Building Code Construction Classification of IIB and will retain this classification following renovation.
The existing building encompasses 35,276 square feet across one story with an actual height of 55 feet, exceeding the allowable building area for certain use classifications and classified as non-conforming for U and S-1 uses but conforming for B use. The project complies with the 2025 New York State Uniform Fire Prevention and Building Code, the 2025 State Energy Conservation Construction Code, and applicable Construction Standards of the State Education Department. No sprinkler system is provided for the facility. The architect has certified that the plans and project manual align with all applicable state building codes and regulations. The architectural documentation includes comprehensive specifications, schedules, legends, and general notes necessary for construction implementation of the office area renovation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ARCHITECTURAL
A0.00 LEGENDS, SYMBOLS, AND DETAILS
A1.01 DEMO, FLOOR AND REFLECTED CEILING PLANS
A3.01 WALL SECTIONS & DETAILS
A5.01 DOOR & WINDOW SCHEDULE
A5.02 STRUCTURAL NOTES & DETAILS
DRAWING INDEX
COVERPAGE
GENERAL
G0.01 CODE COMPLIANCE PLAN - FIRST FLOOR
HVAC
H0.01 LEGENDS, SCHEDULES, DETAILS AND GENERAL NOTES
H0.02 SPECIFICATIONS
H1.01 FLOOR PLAN - DEMOLITION
H2.01 FLOOR PLAN
ELECTRICAL
E0.01 LEGENDS, SCHEDULES AND SPECIFICATIONS
E1.01 FLOOR PLAN - DEMOLITION
E2.01 FLOOR PLAN
358 West Jefferson Street Syracuse, NY 13202 p 315 | 671-2400 f 315 | 671-7891 www.kingarch.com
M A D
IS
O
N C
O U
N
TY
H
IG
H W
AY
G
A R A G
E O
FF
IC
E A R
EA
R
EN
O V
AT
IO
N
Issued for Construction 07/14/2026
-1
1-
K
IN
G
+K
IN
G P
R O
JE
C
T N
U M
BE
R
ARCHITECT'S CERTIFICATION
THE UNDERSIGNED CERTIFIES THAT TO THE BEST OF THEIR KNOWLEDGE, INFORMATION AND
BELIEF, THE PLANS AND PROJECT MANUAL ARE IN ACCORDANCE WITH APPLICABLE
REQUIREMENTS OF THE 2025 NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING
CODE, THE 2025 STATE ENERGY CONSERVATION CONSTRUCTION CODE, CONSTRUCTION
STANDARDS OF THE STATE EDUCATION DEPARTMENT, AND, IF APPLICABLE, THE NEW YORK
STATE DEPARTMENT OF LABOR INDUSTRIAL CODE RULE #56.
LOCATION MAP
crogers New Stamp
MARK DESCRIPTION DATE
Issued for Construction
07/14/2026DRAWING DATE:
DIGITAL REPRODUCTIONS OF THESE
DRAWINGS SHALL NOT BE POSTED TO WEB
SITES WITHOUT THE DIRECT WRITTEN
PERMISSION OF THE ARCHITECT.
IT IS A VIOLATION OF THE STATE EDUCATION
LAW FOR ANY PERSON, UNLESS UNDER THE
DIRECTION OF A LICENSED ARCHITECT TO
ALTER THIS DOCUMENT IN ANY WAY.
ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH THE DESCRIPTION OF THE
ALTERATION AND SIGNATURE AND DATE.
COPYRIGHT ©.
M A
D
IS
O N
C O
U N
TY
H
IG
H
W
AY
G A
R A
G E
O
FF
IC
E
A R
E A
R E
N O
VA
TI
O N
N O
R
TH
C O
U R
T
ST
R E
ET
W
AM
PS
VI
LL
E , N
Y
26-11-9418
KING + KING PROJ. NO.:
G0.01
SCALE:
DRAWING TITLE:
As Noted
CODE COMPLIANCE PLAN
- FIRST FLOOR
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
BUILDING INFORMATION:
OCCUPANCY CLASSIFICATION: Group B - Business (NYSBC Section 304.1)
Group S-1 - Storage, Moderate Hazard (NYSBC Section 311.2)
Group U - Private Garage (NYSBC Section 312)
CONSTRUCTION CLASSIFICATION:
EXISTING: IIB
PROPOSED: IIB
SITE ACCESSIBLE: 4 Sides
SPRINKLER: Sprinkler system not provided.
ALLOWABLE BLDG. AREA: 8,500 (U use is most restrictive or 30,625 SF (S-1 use).
(PER 2025 BUILDING CODE OF NEW YORK STATE - SECTION 506)
ACTUAL BLDG. AREA: for B) 35,276 SF (Existing Non-Conforming for U and S-1, Conforming
ALLOWABLE HEIGHT IN STORIES: 2 STORIES, 55'-0"
(PER 2025 BUILDING CODE OF NEW YORK STATE - SECTION 504)
ACTUAL HEIGHT IN STORIES: 1 STORY, <30'-0"
BUILDING OCCUPANCY: OFFICE: 450 SF / 150 = 3 OCCUPANTS
STORAGE: 34,042 / 500 = 69 OCCUPANTS
BREAK RM. 784 SF / 15 = 53 OCCUPANTS
TOTAL OCCUPANCY = 125
EGRESS CAPACITY: 125 OCCUPANCTS X 0.2" = 25" (USE 36" FOR DOORS)
BUILDING AREAS
DESIGNATION ALLOWABLE AREA* AREA MODIFICATION*
ALLOWABLE AREA +
ADDITIONS
ACTUAL AREA OF
AREA 1
AREA 2
AREA 3
AREA 4
AREA 5
EXISTING BUILDING AREA:
TOTAL BUILDING AREA:
PLUMBING FIXTURE COUNT
125 OCC. 63 FEMALE 63 MALE
Required Fixtures FEMALE MALE Unisex Water Closets 1 1 Lavatories 1 1 Service Sink 1 Drinking Fountains 1
Existing Fixtures FEMALE MALE Unisex Water Closets 1 2 Lavatories 1 2 Urinals 2 Service Sink 1 Drinking Fountains 1
OCCUPANT LOAD
ROOM ROOM AREA PERIMETEROCCUPANCYSQ. FT. / OCC OCCUPANT
NO. NAME SQ. FT. (NET) (NET) TYPE LOAD
FIRST FLOOR
0 SF 0 OCC.
SECOND FLOOR
0 SF 0 OCC.
THIRD FLOOR
0 SF 0 OCC.
FOURTH FLOOR
0 SF 0 OCC.
TOTAL 0 OCC.
NOTES
YELLOW HIGHLIGHT DENOTES INPUT BY USER
BUILDING INFORMATION:
OCCUPANCY CLASSIFICATION: Group B - Business (NYSBC Section 304.1)
Group S-1 - Storage, Moderate Hazard (NYSBC Section 311.2)
Group U - Private Garage (NYSBC Section 312)
CONSTRUCTION CLASSIFICATION:
EXISTING: IIB
PROPOSED: IIB
SITE ACCESSIBLE: 4 Sides
SPRINKLER: Sprinkler system not provided.
ALLOWABLE BLDG. AREA: 8,500 (U use is most restrictive or 30,625 SF (S-1 use).
(PER 2025 BUILDING CODE OF NEW YORK STATE - SECTION 506)
ACTUAL BLDG. AREA: for B) 35,276 SF (Existing Non-Conforming for U and S-1, Conforming
ALLOWABLE HEIGHT IN STORIES: 2 STORIES, 55'-0"
(PER 2025 BUILDING CODE OF NEW YORK STATE - SECTION 504)
ACTUAL HEIGHT IN STORIES: 1 STORY, <30'-0"
BUILDING OCCUPANCY: OFFICE: 450 SF / 150 = 3 OCCUPANTS
STORAGE: 34,042 / 500 = 69 OCCUPANTS
BREAK RM. 784 SF / 15 = 53 OCCUPANTS
TOTAL OCCUPANCY = 125
EGRESS CAPACITY: 125 OCCUPANCTS X 0.2" = 25" (USE 36" FOR DOORS)
PLUMBING FIXTURE COUNT
125 OCC. 63 FEMALE 63 MALE
Required Fixtures FEMALE MALE Unisex Water Closets 1 1 Lavatories 1 1 Service Sink 1 Drinking Fountains 1
Existing Fixtures FEMALE MALE Unisex Water Closets 1 2 Lavatories 1 2 Urinals 2 Service Sink 1 Drinking Fountains 1
OCCUPANT LOAD
ROOM ROOM AREA PERIMETEROCCUPANCYSQ. FT. / OCC OCCUPANT
NO. NAME SQ. FT. (NET) (NET) TYPE LOAD
FIRST FLOOR
0 SF 0 OCC.
SECOND FLOOR
0 SF 0 OCC.
THIRD FLOOR
0 SF 0 OCC.
FOURTH FLOOR
0 SF 0 OCC.
TOTAL 0 OCC.
NOTES
YELLOW HIGHLIGHT DENOTES INPUT BY USER
1 HR. FIRE RATED PARTITION
SMOKE PARTITION
EXIT WIDTH PER OPENING36" E.W.
2 HR. FIRE BARRIER
ALTERATION L1
MINIMAL / NO WORK
NWC/NDF NEW WATER COOLER /DRINKING FOUNTAIN
N.F.E. NEW FIRE EXTINGUISHER LOCATION
RATED PARTITION LEGEND:
CONSTRUCTION TYPE DESIGNATIONS:
EMERGENCY EGRESS LEGEND:
GENERAL LEGEND:
ALTERATION L2
E.F.E. EXISTING FIRE EXTINGUISHER LOCATION
EWC/EDF EXG. WATER COOLER /DRINKING FOUNTAIN
ALL EXISTING PARTITIONS ARE ASSUMED TO HAVE THE
REQUIRED RATINGS BASED ON THE EXISTING AS-BUILTS.
GENERAL NOTES
GENERAL NOTES - ALL TRADES
AND AS FOLLOWS:
CONCEALED SHALL BE PROTECTED AS DESCRIBED IN DIVISIONS 21, 22, 23, 26, 27 AND 28, OR SMOKE BARRIERS (WALLS, FLOORS, AND ROOF) WHETHER EXPOSED OR
DUCTS, AND SIMILAR BUILDING SERVICE EQUIPMENT THROUGH EXISTING OR NEW FIRE
G-1 ALL PASSAGES OF EXISTING AND NEW PIPES, CONDUITS, CABLES, WIRES, AIR
MAINTAINING AN AIR TIGHT CONDITION.
THE FIRE/SMOKE BARRIER, DESIGNED FOR THE SPECIFIC PURPOSE, AND CAPABLE OF
BE FILLED WITH A MATERIAL CAPABLE OF MAINTAINING THE FIRE/SMOKE RESISTANCE OF
a. THE SPACE BETWEEN THE PENETRATING ITEM AND THE FIRE/SMOKE BARRIER SHALL
CONDITION.
DESIGNED FOR THE SPECIFIC PURPOSE, AND CAPABLE OF MAINTAINING AN AIR TIGHT
CAPABLE OF MAINTAINING THE FIRE/SMOKE RESISTANCE OF THE FIRE/SMOKE BARRIER,
SPACE BETWEEN THE ITEM AND THE SLEEVE SHALL BE FILLED WITH A MATERIAL
BARRIER, THE SLEEVE SHALL BE SOLIDLY SET IN THE FIRE/SMOKE BARRIER AND THE
b. WHERE THE PENETRATING ITEM USES A SLEEVE TO PENETRATE THE FIRE/SMOKE
AS POSSIBLE AND TO THE OWNER'S SATISFACTION.
TO CLEAN UP AFTER ALL OPERATIONS IN ORDER TO KEEP THE AREA AND SITE AS CLEAN
REMAIN IN USE DURING CONSTRUCTION, THEREFORE, SPECIAL CARE SHALL BE TAKEN
G-2 ALL OTHER AREAS OF THE BUILDING WHERE ANY WORK IS TO BE DONE SHALL
LOCATION OF THESE PARTITIONS SHALL BE COORDINATED WITH THE OWNER.
INSTALLED AROUND THE LOCATION OF WORK TAKING PLACE. THE EXTENT AND
G-3 AT ALL TIMES THAT WORK IS GOING ON, DUST TIGHT PARTITIONS SHALL BE
SHALL BE REPAIRED AND PATCHED WITH MATCHING CONSTRUCTION AND FINISHES.
STRUCTURE WHICH ARE DAMAGED OR REMOVED DUE TO DEMOLITION, OR NEW WORK
PROTECTED FROM DAMAGE. ALL EXISTING SURFACES, WORK, EQUIPMENT, AND
G-4 ALL EXISTING FINISHES, WORK, EQUIPMENT, AND STRUCTURE TO REMAIN ARE TO BE
CLEANING OF SURFACES AS PER MANUFACTURER'S INSTRUCTIONS, ETC.
FINISHES, INCLUDING FINISH PATCHING OF NEW AND EXISTING HOLES, VOIDS, CRACKS,
G-5 NOTED EXISTING AND NEW SURFACES ARE TO BE PREPARED TO RECEIVE NEW
LOCATION OF NEW OR RELOCATED ITEMS.
G-6 CONTRACTOR IS TO COORDINATE WITH ARCHITECT AND OWNER THE EXACT
ELECTRICAL ITEMS.
WALLS, AND FLOORS DISTURBED FOR THE INSTALLATION OF MECHANICAL AND
G-7 CONTRACTOR TO PATCH AND REPAIR TO MATCH EXISTING AREAS OF CEILINGS,
SURFACES TO MATCH EXISTING AND PREPARE SURFACES FOR NEW FINISH.
G-8 WHERE EQUIPMENT, ETC. HAS BEEN REMOVED BY OWNER, CONTRACTOR TO PATCH
STAIRS SHALL BE MAINTAINED AT ALL TIMES.
G-9 WORK SHALL NOT INTERFERE WITH LEGAL FIRE EXITS. ALL CORRIDORS AND EXIT
MAINTAINED OR RESTORED.
ALL OPENINGS SHALL BE SEALED AIR TIGHT, AND WHERE APPLICABLE, FIRE RATINGS
EXISTING FLOORS AND WALLS WITH CONSTRUCTION AND FINISH TO MATCH EXISTING.
G-10 PATCH ALL OPENINGS (NEW AND EXISTING) WHETHER EXPOSED OR CONCEALED IN
SURFACES, JOINTS, ETC. SHALL BE EASILY CLEANABLE.
G-11 ALL PENETRATIONS INTO RENOVATED ROOMS SHALL BE SEALED AND ALL
ARCHITECTURAL PLANS, DETAILS, END BEARING REQUIREMENTS AND DIVISION 23.
THAT CORRECT HEIGHT AND LENGTH OF LINTELS WILL BE OBTAINED. COORDINATE WITH
THOSE TO BE PROVIDED FOR DUCTWORK AND OTHER MECHANICAL PENETRATIONS, SO
G-12 CONTRACTOR SHALL VERIFY ALL MASONRY OPENING DIMENSIONS, INCLUDING
LINTELS OVER ALL OPENINGS THROUGH MASONRY WALLS AND PARTITIONS.
G-13 EXCEPT WHERE OTHERWISE SCHEDULED OR INDICATED, PROVIDE LOOSE STEEL
GENERAL STRUCTURAL NOTES - ALL TRADES
BEAMS, JOISTS, OR BRIDGING RIBS WITHOUT THE ARCHITECT'S APPROVAL.
1. DO NOT DRILL, CORE, OR CUT ANY PORTION OF EXISTING CONCRETE COLUMNS,
DRAWINGS WITHOUT THE ARCHITECT'S APPROVAL.
2. DO NOT CUT OPENINGS THROUGH EXISTING CONCRETE WHICH ARE NOT SHOWN ON
3. CORE-DRILL NEW OPENINGS WHEREVER POSSIBLE.
CONCRETE AS FOLLOWS:
4. WHERE CORE-DRILLING IS NOT PRACTICAL, CUT OPENING THROUGH EXISTING
NO PORTION OF EXISTING BEAMS OR JOISTS WILL BE ALTERED IN ANY WAY.
a. PRIOR TO CUTTING, DETERMINE THE LOCATION OF PROPOSED OPENINGS SUCH THAT
THE FOUR CORNERS OF NEW OPENING.
b. CORE-DRILL ROUND HOLES THROUGH EXISTING SUPPORTING STRUCTURAL SLABS AT
REMOVE CONCRETE.
c. SAW-CUT STRUCTURAL SLAB TO MINIMUM DEPTH OF 2" BETWEEN HOLES AND
GENERAL NOTES - 2025 NYSBC:
MAXIMUM CORRIDOR TRAVEL DISTANCE TO EXITS IN
FEET (NYSBC T 1017.2):
- 200 FEET
NOTE: TRAVEL DISTANCES COMPLY W/ THESE
REQUIREMENTS.
CORRIDOR FIRE RESISTANCE RATINGS
(PER 2025 BUILDING CODE OF NYS - SECTION T 1020.2):
- 1 HOUR min.
ALL NEW WORK IS DESIGNED TO COMPLY WITH ICC A117.1 -
2017 'STANDARD FOR ACCESSIBLE AND USABLE BUILDINGS
AND FACILITIES.'
MAXIMUM COMMON PATH OF TRAVEL IN FEET (NYSBC
T 1006.2.1):
- 75 FEET
NOTE: TRAVEL DISTANCES COMPLY W/ THESE
REQUIREMENTS.
GENERAL NOTES - 2025 NYSEBC:
CH. 3, 7, 8: ALL NEW WORK SHALL COMPLY WITH BCNYS.
CH. 10 - CHANGE OF USE TO PORTION OF BLDG. (S-1 TO B)
-1007: ALL NEW ELECTRICAL IN OFFICE AREA
SHALL MEET NYSBC.
-1008: ALL NEW MECHANICAL IN OFFICE AREA
SHALL MEET NYSBC.
-1009: PLUMBING FIXTURE DEMAND: ADEQUATE
FACILITIES EXIST.
1010.1: LIGHT & VENTILATION FOR NEW USE SHALL
MEET NYSBC.
1011 - AUTOMATIC SPRINKLER SYSTEM NOT FOR
AREA WITH CHANGE OF OCCUPANCY (BUSINESS)
T 1011.5: S-1 TO B = EQUAL HAZARD RATING:
EXISTING ELEMENTS OF MEANS OF EGRESS
SHALL COMPLY WITH SECTION 905.
T 1011.6: S-1 TO B = LOWER HAZARD RATING:
THE HEIGHT AND AREA OF THE EXISTING
BUILDING SHALL BE DEEMED ACCEPTABLE.
T 1011.7: S-1 TO B = LOWER HAZARD RATING:
EXISTING EXTERIOR WALLS AND OPENINGS SHALL
BE ACCEPTED.
NYSBC 406 MOTOR VEHICLE RELATED OCCUPANCIES
-406.9.3 PRIVATE GARAGES SHALL COMPLY
WITH 406.2 AND 406.3.
-EXISTING PRIVATE GARAGE IS EXISTING
NON-CONFORMING. NEW WORK
TO ENLARGE OFFICE AREA SHALL MEET 406.2
AND 406.3.
-406.3.1 AND 406.3.2: PRIVATE GARAGE IS
CLASSIFIED AS GROUP U AND SHALL BE
SEPARATED PER 508.
-508.2: ACCESSORY OCCUPANCIES ARE THOSE
THAT ARE ANCILLARY TO THE MAIN
OCCUPANCY OF THE BUILDING.
(ANCILLARY DEFINED IN THIS CASE AS: A
SPACE THAT PROVIDES NECESSARY SUPPORT
TO A PRIMARY ACTIVITY. I.E. STAFF DIRECTLY
RELATED TO HIGHWAY DEPT. ACTIVITIES.)
508.2.4: NO SEPARATION IS REQUIRED
BETWEEN ACCESSORY OCCUPANCIES AND
THE MAIN OCCUPANCY.
EX.23 EX.24 EX.25 EX.26
EX.F
EX.G
EX.H
EX.J
EX.K
EX.L
EX.M
EX.N
EX.P
EX.R
BREAK RM.
MEN'S LOCKER RM.
OFFICE
CORRIDOR
STOCK RM.
REPAIR SHOP
STORAGE RM.
WELDING SHOP
CARPENTRY SHOP
TRUCK PARKING
TOILET
107A
OFFICE
W-1
W-1
EXIT ACCESS TRAVEL
DISTANCE = 34'-0"
EXIT ACCESS TRAVEL
DISTANCE = 34'-0"
36" E.W.
36" E.W.
GENERAL NOTES
GENERAL NOTES - ALL TRADES
AND AS FOLLOWS:
CONCEALED SHALL BE PROTECTED AS DESCRIBED IN DIVISIONS 21, 22, 23, 26, 27 AND 28, OR SMOKE BARRIERS (WALLS, FLOORS, AND ROOF) WHETHER EXPOSED OR
DUCTS, AND SIMILAR BUILDING SERVICE EQUIPMENT THROUGH EXISTING OR NEW FIRE
G-1 ALL PASSAGES OF EXISTING AND NEW PIPES, CONDUITS, CABLES, WIRES, AIR
MAINTAINING AN AIR TIGHT CONDITION.
THE FIRE/SMOKE BARRIER, DESIGNED FOR THE SPECIFIC PURPOSE, AND CAPABLE OF
BE FILLED WITH A MATERIAL CAPABLE OF MAINTAINING THE FIRE/SMOKE RESISTANCE OF
a. THE SPACE BETWEEN THE PENETRATING ITEM AND THE FIRE/SMOKE BARRIER SHALL
CONDITION.
DESIGNED FOR THE SPECIFIC PURPOSE, AND CAPABLE OF MAINTAINING AN AIR TIGHT
CAPABLE OF MAINTAINING THE FIRE/SMOKE RESISTANCE OF THE FIRE/SMOKE BARRIER,
SPACE BETWEEN THE ITEM AND THE SLEEVE SHALL BE FILLED WITH A MATERIAL
BARRIER, THE SLEEVE SHALL BE SOLIDLY SET IN THE FIRE/SMOKE BARRIER AND THE
b. WHERE THE PENETRATING ITEM USES A SLEEVE TO PENETRATE THE FIRE/SMOKE
AS POSSIBLE AND TO THE OWNER'S SATISFACTION.
TO CLEAN UP AFTER ALL OPERATIONS IN ORDER TO KEEP THE AREA AND SITE AS CLEAN
REMAIN IN USE DURING CONSTRUCTION, THEREFORE, SPECIAL CARE SHALL BE TAKEN
G-2 ALL OTHER AREAS OF THE BUILDING WHERE ANY WORK IS TO BE DONE SHALL
LOCATION OF THESE PARTITIONS SHALL BE COORDINATED WITH THE OWNER.
INSTALLED AROUND THE LOCATION OF WORK TAKING PLACE. THE EXTENT AND
G-3 AT ALL TIMES THAT WORK IS GOING ON, DUST TIGHT PARTITIONS SHALL BE
SHALL BE REPAIRED AND PATCHED WITH MATCHING CONSTRUCTION AND FINISHES.
STRUCTURE WHICH ARE DAMAGED OR REMOVED DUE TO DEMOLITION, OR NEW WORK
PROTECTED FROM DAMAGE. ALL EXISTING SURFACES, WORK, EQUIPMENT, AND
G-4 ALL EXISTING FINISHES, WORK, EQUIPMENT, AND STRUCTURE TO REMAIN ARE TO BE
CLEANING OF SURFACES AS PER MANUFACTURER'S INSTRUCTIONS, ETC.
FINISHES, INCLUDING FINISH PATCHING OF NEW AND EXISTING HOLES, VOIDS, CRACKS,
G-5 NOTED EXISTING AND NEW SURFACES ARE TO BE PREPARED TO RECEIVE NEW
LOCATION OF NEW OR RELOCATED ITEMS.
G-6 CONTRACTOR IS TO COORDINATE WITH ARCHITECT AND OWNER THE EXACT
ELECTRICAL ITEMS.
WALLS, AND FLOORS DISTURBED FOR THE INSTALLATION OF MECHANICAL AND
G-7 CONTRACTOR TO PATCH AND REPAIR TO MATCH EXISTING AREAS OF CEILINGS,
SURFACES TO MATCH EXISTING AND PREPARE SURFACES FOR NEW FINISH.
G-8 WHERE EQUIPMENT, ETC. HAS BEEN REMOVED BY OWNER, CONTRACTOR TO PATCH
STAIRS SHALL BE MAINTAINED AT ALL TIMES.
G-9 WORK SHALL NOT INTERFERE WITH LEGAL FIRE EXITS. ALL CORRIDORS AND EXIT
MAINTAINED OR RESTORED.
ALL OPENINGS SHALL BE SEALED AIR TIGHT, AND WHERE APPLICABLE, FIRE RATINGS
EXISTING FLOORS AND WALLS WITH CONSTRUCTION AND FINISH TO MATCH EXISTING.
G-10 PATCH ALL OPENINGS (NEW AND EXISTING) WHETHER EXPOSED OR CONCEALED IN
SURFACES, JOINTS, ETC. SHALL BE EASILY CLEANABLE.
G-11 ALL PENETRATIONS INTO RENOVATED ROOMS SHALL BE SEALED AND ALL
ARCHITECTURAL PLANS, DETAILS, END BEARING REQUIREMENTS AND DIVISION 23.
THAT CORRECT HEIGHT AND LENGTH OF LINTELS WILL BE OBTAINED. COORDINATE WITH
THOSE TO BE PROVIDED FOR DUCTWORK AND OTHER MECHANICAL PENETRATIONS, SO
G-12 CONTRACTOR SHALL VERIFY ALL MASONRY OPENING DIMENSIONS, INCLUDING
LINTELS OVER ALL OPENINGS THROUGH MASONRY WALLS AND PARTITIONS.
G-13 EXCEPT WHERE OTHERWISE SCHEDULED OR INDICATED, PROVIDE LOOSE STEEL
GENERAL STRUCTURAL NOTES - ALL TRADES
BEAMS, JOISTS, OR BRIDGING RIBS WITHOUT THE ARCHITECT'S APPROVAL.
1. DO NOT DRILL, CORE, OR CUT ANY PORTION OF EXISTING CONCRETE COLUMNS,
DRAWINGS WITHOUT THE ARCHITECT'S APPROVAL.
2. DO NOT CUT OPENINGS THROUGH EXISTING CONCRETE WHICH ARE NOT SHOWN ON
3. CORE-DRILL NEW OPENINGS WHEREVER POSSIBLE.
CONCRETE AS FOLLOWS:
4. WHERE CORE-DRILLING IS NOT PRACTICAL, CUT OPENING THROUGH EXISTING
NO PORTION OF EXISTING BEAMS OR JOISTS WILL BE ALTERED IN ANY WAY.
a. PRIOR TO CUTTING, DETERMINE THE LOCATION OF PROPOSED OPENINGS SUCH THAT
THE FOUR CORNERS OF NEW OPENING.
b. CORE-DRILL ROUND HOLES THROUGH EXISTING SUPPORTING STRUCTURAL SLABS AT
REMOVE CONCRETE.
c. SAW-CUT STRUCTURAL SLAB TO MINIMUM DEPTH OF 2" BETWEEN HOLES AND
07/14/2026DRAWING DATE:
DIGITAL REPRODUCTIONS OF THESE
DRAWINGS SHALL NOT BE POSTED TO WEB
SITES WITHOUT THE DIRECT WRITTEN
PERMISSION OF THE ARCHITECT.
IT IS A VIOLATION OF THE STATE EDUCATION
LAW FOR ANY PERSON, UNLESS UNDER THE
DIRECTION OF A LICENSED ARCHITECT TO
ALTER THIS DOCUMENT IN ANY WAY.
ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH THE DESCRIPTION OF THE
ALTERATION AND SIGNATURE AND DATE.
COPYRIGHT ©.
M A
D
IS
O N
C O
U N
TY
H
IG
H
W
AY
G A
R A
G E
O
FF
IC
E
A R
E A
R E
N O
VA
TI
O N
N O
R
TH
C O
U R
T
ST
R E
ET
W
AM
PS
VI
LL
E , N
Y
A0.00
SCALE:
DRAWING TITLE:
As Noted
LEGENDS, SYMBOLS,
AND DETAILS
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
101-1
101-2
1'-6"
3' -0
TYPICAL DOOR DIMENSIONS
4"
THE DRAWING COORDINATE SYSTEM IS USED TO STANDARDIZE NUMBERING FROM DRAWING TO DRAWING AND
FROM PROJECT TO PROJECT.
EACH SHEET SIZE IS BROKEN INTO COLUMNS AND ROWS STARTING AT THE BOTTOM LEFT CORNER OF THE SHEET. EACH QUADRANT IS NUMBERED ACCORDING TO ITS LOCATION ON THE GRID. THE ROW IS THE FIRST CHARACTER, AND IS ALWAYS A LETTER. THE COLUMN IS THE SECOND CHARACTER, AND IS ALWAYS A NUMBER.
E1 E2 E3 E4 E5
D1 D2 D3 D4 D5
C1 C2 C3 C4 C5
D6
C6
B1 B2 B3 B4 B5 B6
A6A5A4A3A2A1
COLUMNS
R O W S
DRAWING COORDINATE SYSTEM:
E
D
C
B
A
E6
1 2 3 4 5 6
MATERIAL INDICATION
ACOUSTIC TILE
ALUMINUM
BRICK
CERAMIC TILE
CONCRETE
CONCRETE BLOCK
DRYWALL CEILING
EARTH (UNDISTURBED)
GLASS
GLAZED STRUCTURAL TILE
GRAVEL
GYPSUM DRYWALL
LIGHT WEIGHT CONCRETE
METAL STUD PARTITION
PLASTER
PLYWOOD
RIGID INSULATION
STEEL
WOOD BLOCKING
WOOD SHIM
WOOD FINISHED
PATCHING
EARTH (DISTURBED)
EXISTING CONSTRUCTION
ABBREVIATIONS
PAR: parallel PC: piece PCC: precast concrete PCT: porcelain tile PREFAB: prefabricated PFN: prefinished PLAM: plastic laminate PLAS: plaster PLMB: plumbing(er) PL: plate PNL: panel PT: paint PR or P: pair PT: pressure treated PRF: preformed PSI: pounds per square inch PWD or PLYWD: plywood QT: quarry tile RAD: radius RB: rubber base RD: roof drain RE: reinforce(ed)(ing) REF: reference REQ'D: required REV: revision(s) or revised RFT: rubber floor tile RFG: roofing RM: room RO: rough opening RSF: resilient sports flooring RSL: rubber stair landings RSR: rubber stair risers RST: rubber stair treads RT: rubber tile RWC: rainwater conductor S: south SC: stained concrete SCH or SCHED: schedule SECT: section SFCMU: split face cmu SF or SQFT: square foot SGT: structural glazed facing tile SHT: sheet SHTG: sheathing SIM: similar SIN or SQIN: square inch SK: sink SPEC: specification SQ: square SS: solid surface SST: stainless steel ST: steel STA: station STD: standard STF: stiffener
@: at ACM: asbestos containing material ACT: acoustical ceiling tile AD: access door ADJ: adjustable AFF: above finish floor AL: aluminum ALT: alternate AP: access panel APPROX: approximate(ly) ARCH: architect(ural) ASSY: assembly AVG: average AWP: acoustic wall panel BD: board BLDG: building BLKG: blocking BM: bench mark BOT: bottom BO: bottom of BR: bumper rail BS: backsplash or both sides BSMT: basement BUR: built-up roof C: courses C/L: center line CB: chalkboard CC: cubical curtain CFMF: cold form metal framing CFT: cubic foot CG: corner guard CJ: control joint CL: closet CLG: ceiling CLR: clear CMT: ceramic mosaic tile CMU: concrete masonry unit COL: column CONC: concrete CONST: construction CONT: continue or continuous CONV: convector COORD: coordinate CPT: carpet CSWK: casework CT: ceramic tile CTR: counter CW: curtainwall CWT: ceramic wall tile CYD: cubic yard DF: drinking fountain DHW: domestic hot water DIA: diameter DIM: dimension DN: down
DIV: division DPCO: deck plate clean out DR: door DTL or DET: detail DWG: drawing E: east EA: each EB: expansion bolt EF: exhaust fan EIFS: exterior insulation finish system EL or ELEV: elevation ELEC: electric ENGR: engineer EPDM: ethylene propylene diene monomer EQ: equal EQP or EQUIP: equipment ETC: etcetera ETR: existing to remain EWC: electric watercooler EJ: expansion joint EXCA: excavation EXG: existing EXP: expansion or exposed EXT: exterior FAB: fabric FD: floor drain FE: fire extinguisher FEC: fire extinguisher cabinet FF: finish floor FIN: finish FLG: flashing FLR: floor FND: foundation FO: face of FP: fireproof or fire protection FR: fire rated FRG: fire rated glass FRP: fiber reinforced panel FSTN: fasten FTG: footing FUR: furred FWC: fabric wall covering GA: gauge GB: grab bar GCT: glazed ceramic tile GD or GR: grade GL: glass GPDW: gypsum drywall GV or GALV: galvanized GWT: glazed wall tile GYP: gypsum HM: hollow metal HORIZ: horizontal HPC: high performance coating
HR: hour HT or HGT: height HVAC: heating, ventilating, & air conditioning HW: hardware HWD: hardwood ID: inside diameter IG: insulating glass INS or INSUL: insulation INT: interior INV: invert ITFG: insulated tempered float glass INFO: information IWB: interactive white board JST: joist JC or JAN: janitor's closet JT: joint KP: kickplate LIN: linoleum LKR: locker LOC: location LLH: long leg horizontal LLV: long leg vertical MAS: masonry MAX: maximum MB: markerboard MECH: mechanical MEMB: membrane MEJ: masonry expansion joint MET: metal MFR: manufacture(er)(ed)
MIL: 1/1000"
MIN: minimum MISC: miscellaneous MO: masonry opening MS: machine screw MT or MTD: mount(ed) MTG: mounting MTL: material NO or #: number N: north NAT: natural NIC: not in contract NOM: nominal NTS: not to scale OC: on center OD: outside diameter OFCI: owner furnished contractor installed OH: overhead door OPG: opening OPP: opposite
STN: stain STOR: storage STRUCT: structural SUSP: suspend(ed) SVF: sheet vinyl flooring SY or SQYD: square yard T: tread TB: tackboard T&B: top and bottom T&G: tongue and groove TEMP: temperature or temporary TERR or TZ: terrazzo TH or THK: thick(ness) THD: threshold TLT or TOIL: toilet TO: top of TOC or T/C: top of concrete TOF or T/F: top of footing TOJ: top of joist TOM: top of masonry TOS: top of steel TOW: top of wall TP: translucent panel TPO: thermoplastic polyolefin TYP: typical UL: Underwriter's Laboratories, Inc.
UNO: unless noted otherwise VAT: vinyl asbestos tile VB: vapor barrier VCT: vinyl composition tile VERT: vertical VEST: vestibule VIF: verify in field VWF: vinyl wall fabric VIN: vinyl VWC: vinyl wall covering W: wide, width, or west W/: with W/O: without WCV: wall covering WD: wood WDV: wood veneer finish WI: wrought iron WIN: window WS: waterstop or weatherstripping WP: wall protection WSCT: wainscot WT: weight WWM: welded wire mesh
GRAPHIC SYMBOLS
W1
(ACCESSIBILITY
ICON)
(ROOM AREA)
101-1 V1
W1
S6
(INTERIOR
WINDOW ID)
(PARTITION
TYPE ID)
(DOOR ID)
(EXISTING DOOR)
(DEMO WALL) (DEMO DOOR)
(DEMO OBJECT)
DRAWING #
SHEET #
(DRAWING LABEL)
D RA WI NG TI TL E
(18 point font)
(9 point font)
(EXTERIOR
ELEVATIONS)
(BUILDING AND
WALL SECTIONS)
(DETAIL
CALLOUT)
B1 A3.01
(SINGLE INTERIOR
ELEVATION)
(EXTERIOR
WINDOW ID)
(LOUVER ID)
L1
A1 A3.02
0 10 20 ft (NORTH ARROW)
(GRAPHIC SCALE)
(REVISION
NOTE)
(DEMO KEYED NOTE)
(CONSTRUCTION
KEYED NOTE)
A
B
A
B
(MATCH LINE)
MB-1
(EQUIP. DESIGNATION)
ALIGN
A
B
C
D
A4.01
CLASSROOM
AREA : 782 SF
CLASSROOM
AREA : 782 SF
(ROOM NUMBER)
(ROOM NAME)
A1 A4.01
D2
A9.01
D.1
(COUNTER AND
BACKSPLASH:
SOLID LINE)
(CABINET ABOVE
COUNTER: LONG
DASHED LINE)
(CABINET BELOW
COUNTER: SHORT
DASHED LINE)
C1 A9.01
2 31
A
B
C
D
(COLUMN GRID)
(MULTI INTERIOR
ELEVATIONS)
(COLUMN ID)
ACOUSTIC CEILING
SYSTEM, 2X4 OR 2X2
AS SHOWN ON DWG
DRYWALL/PLASTER
SPRINKLER HEAD
2X2 LIGHT FIXTURE
2X4 LIGHT FIXTURE
LINEAR LED FIXTURE
DOWNLIGHT
2X2 EMERGENCY
2X4 EMERGENCY
LINEAR EMERGENCY
DOWNLIGHT EMERGENCY
HVAC SUPPLY DIFFUSER
HVAC RETURN GRILLE
HVAC LINEAR DIFFUSER
RADIANT CEILING PANEL
CABINET UNIT HEATER
S SPEAKER
OS OCCUPANCY SENSOR
FIRE DETECTORF
ACCESS PANEL
CR CORD REEL
CURTAIN TRACK
REFLECTED CEILING PLAN SYMBOLS
EXIT LIGHT WALL MT
EXIT LIGHT CEILING MT
REFLECTED CEILING PLAN SYMBOLS
GENERAL NOTES:
1. ALL NEW PARTITIONS ARE DIMENSIONED FROM FACE OF STEEL STUD OR FACE OF BLOCK, UNLESS OTHERWISE NOTED.
2. ALL STEEL STUDS SHALL HAVE 1 LAYER GPDW EACH SIDE, UNLESS NOTED OTHERWISE.
3. EXTEND ALL PARTITIONS, STUDS, AND GPDW TO DECK ABOVE, UNLESS NOTED OTHERWISE.
4. ALL DRYWALL TO BE 5/8” THICK, UNLESS NOTED OTHERWISE.
5. WHERE UNBALANCED DRYWALL SYSTEM IS USED, ADDITIONAL LAYER IS ON SYMBOL SIDE.
6. SEE SPECIFICATIONS FOR THICKNESS OF ACOUSTIC INSULATION.
7. SEE FINISH SCHEDULE FOR FINISHES INCLUDING PAINT, SPECIALTY COATINGS, TILE, VINYL WALL COVERINGS, ETC. AT
LOCATIONS SCHEDULED TO RECEIVE WALL TILE, PROVIDE CEMENTITIOUS BACKER BOARD IN LIEU OF GPDW.
8. REFER TO CODE COMPLIANCE DRAWINGS FOR LOCATION OF RATED WALLS.
9. WHERE GPDW DOES NOT EXTEND FROM FLOOR TO DECK ON BOTH SIDES OF METAL STUD WALLS, PROVIDE STEEL CHANNEL
AND CLIP ANGLE BRIDGING AS SPECIFIED AT 4'-0” MAXIMUM ON CENTER, FULL HEIGHT OF ASSEMBLY. WHERE STUD KNOCKOUTS DON'T ALIGN OR ARE BLOCKED BY OTHER CONSTRUCTION, PROVIDE METAL STRAPPING AS SPECIFIED ON BOTH
FACES OF STUDS AT SAME SPACING.
10. AT DEFLECTION TRACK LOCATIONS OF RATED WALLS, PROVIDE CHANNEL AND CLIP BRIDGING OR STRAPPING AT 1'-0” MAXIMUM
BELOW STRUCTURE ABOVE.
PARTITION TYPES
758" 8" CONCRETE MASONRY UNITS
* MINIMUM EQUIVALENT THICKNESS: 4.0
* STC: 47
* FIRE RESISTANCE RATING: 1, 2 HOURS WHERE
INDICATED ON DRAWINGS
* REFERENCE BCNYS TABLE 722.3.2 AND PARAGRAPH
722.3.2.3
M8
07/14/2026DRAWING DATE:
DIGITAL REPRODUCTIONS OF THESE
DRAWINGS SHALL NOT BE POSTED TO WEB
SITES WITHOUT THE DIRECT WRITTEN
PERMISSION OF THE ARCHITECT.
IT IS A VIOLATION OF THE STATE EDUCATION
LAW FOR ANY PERSON, UNLESS UNDER THE
DIRECTION OF A LICENSED ARCHITECT TO
ALTER THIS DOCUMENT IN ANY WAY.
ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH THE DESCRIPTION OF THE
ALTERATION AND SIGNATURE AND DATE.
COPYRIGHT ©.
M A
D
IS
O N
C O
U N
TY
H
IG
H
W
AY
G A
R A
G E
O
FF
IC
E
A R
E A
R E
N O
VA
TI
O N
N O
R
TH
C O
U R
T
ST
R E
ET
W
AM
PS
VI
LL
E , N
Y
A1.01
SCALE:
DRAWING TITLE:
As Noted
DEMO, FLOOR AND
REFLECTED CEILING
PLANS
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
CONSTRUCTION GENERAL NOTES
A. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION.
B. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BETWEEN DRAWINGS, SCHEDULES,
AND/OR SPECIFICATIONS FOR CLARIFICATION.
C. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD OR CMU UNLESS NOTED OTHERWISE. AT
EXISTING PARTITIONS, DIMENSIONS ARE TAKEN FROM FACE OF EXISTING FINISH.
D. WHERE NEW MASONRY IS BEING INSTALLED NEXT TO EXISTING MASONRY, TOOTH
MASONRY IN AT ALL LOCATIONS, UNLESS OTHERWISE NOTED.
E. WHERE EQUIPMENT/ CASEWORK WAS REMOVED FROM EXISTING WALLS, PATCH WALLS TO
MATCH ADJACENT EXISTING SURFACES OR TO RECEIVE NEW FINISHES AS SCHEDULED.
F. WHERE EXISTING WALLS WERE REMOVED, PATCH WALLS AND FLOORS TO MATCH
ADJACENT EXISTING SURFACES OR TO RECEIVE NEW FINISHES AS SCHEDULED.
G.
WHERE EXISTING DOOR FRAMES ARE SCHEDULED TO BE REPAINTED, EXISTING PRIMER
AND PAINT ARE TO BE SANDED DOWN TO A SMOOTH SURFACE BEFORE NEW COATS OF
PRIMER AND PAINT ARE APPLIED. REFER TO DOOR/FINISH SCHEDULES FOR DOOR FRAMES
OF SPLIT COLORS.
H.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBILE FOR CUTTING AND PATCHING OF
EXISTING AND/OR NEW WALLS, FLOORS, ROOFS, ETC. AND COORDINATING WITH MEP
TRADES.
CONSTRUCTION KEYED NOTES
CONSTRUCTION KEYED NOTES ARE INDICATED ON DRAWINGS WITH A CIRCLE.
NOT ALL NOTES LISTED BELOW APPLY TO THIS SHEET.
1 ALIGN FACE OF NEW WALL WITH FACE OF ADJACENT EXISTING WALL, BOTH SIDES WHERE
APPLICABLE.
2 INFILL EXISTING OPENING AS INDICATED. ALIGN FACE OF NEW CONSTRUCTION WITH FACE
OF EXISTING, BOTH SIDES. FINISH TO MATCH ADJACENT OR AS SCHEDULED.
3 LAMINATE 5/8" GPDW TO EXISTING CMU WALL AS INDICATED TO 6" ABOVE CEILING, TYP.
RETURN TO DOOR/WINDOW/VISION PANEL FRAME WHERE APPLICABLE.
4 FURNISH & INSTALL NEW WALL EXPANSION JOINT COVER AS SPECIFIED.
5 FURNISH & INSTALL NEW FLOOR EXPANSION JOINT COVER AS SPECIFIED.
6 FLOOR MOUNTED TOILET PARTITION. SEE SPECIFICATIONS.
FURNISH & INSTALL COUNTERTOP GRILLE WITH PENCIL PROOF VENT AT LOCATIONS
INDICATED. COORDINATE WITH FIN TUBE AND HVAC DRAWINGS. REFER TO CASEWORK
DETAILS AND SPECIFICATIONS FOR DESCRIPTION.
8 PROVIDE BLOCKING AS REQUIRED FOR SMARTBOARD INSTALLATION BY DISTRICT.
COORDINATE WITH ELECTRICAL DRAWINGS.
EX.23 EX.24 EX.25 EX.26
EX.F
EX.G
EX.H
EX.J
EX.K
EX.L
EX.M
MEN'S LOCKER RM.
OFFICE
CORRIDOR
TRUCK PARKING
TOILET
107A
OFFICE
W-1
W-1
FLOOR PLAN - PARTIAL
Scale: 1/4" = 1'-0"
B3 A1.01
KEYED CONSTRUCTION NOTES
REINFORCE CMU WALL WITH #5 REBAR @ 48" O.C. VERTICALLY (CENTERED), TYP. DRILL & EPOXY #5 BARS 5" MIN. INTO EXIST.
CONC. SLAB ON GRADE. LAP ALL BARS IN ACCORDANCE WITH MASONRY LAP SPLICE SCHEDULE. REINFORCE CMU WALLS W/ HORIZONTAL JOINT REINFORCING PER THE SPECIFICATIONS AND WITH 8" WIDE x 8" HIGH BOND BEAM AT TOP OF WALL. SEE TYPICAL WALL REINFORCING DETAILS FOR REINFORCING AROUND OPENINGS AND AT ENDS OF WALLS.
PROVIDE LINTEL L-1 ABOVE OPENING: (2) L6 x 3.5 x 5/16 LLV, GALVANIZED STEEL. 6" MIN. END BEARING.
PROVIDE LINTEL L-2 ABOVE OPENING: 8" WIDE x 8" HIGH BOND BEAM w/ (2) #5 REBAR CONTINUOUS.
W6x12 STEEL BEAM ABOVE CEILING, BEARING ON CMU WALLS WITH 1/2" x 5" x 7" BEARING PLATE ON 3/4" MIN. NON-SHRINK GROUT AT BOTH ENDS AND AT INTERMEDIATE MASONRY PIER. SEE TYPICAL BEAM BEARING ON MASONRY DETAIL. REFER TO
SECTION FOR INSTALL ELEVATION.
ANCHOR CMU WALL ENDS ABUTTING PERPENDICULAR EXISTING CMU WALL PER TYPICAL DETAIL ON A5.02.
HVAC CONDENSER ON PREFABRICATED STEEL ANGLE RACK ATTACHED TO CMU. REFER TO SECTION DETAIL.
PAINTED PLYWOOD COUNTER @ 34" A.F.F.
PROVIDE LINTEL L-3 ABOVE LOUVER OPENING: (2) L4 x 3 x 5/16 LLV GALVANIZED STEEL. REFER TO HVAC DWGS. AND
TYPICAL DETAIL. MODIFY METAL SIDING AS REQUIRED.
D4 A3.01
6'-4"3'-4"
M.O.
4'-8"
4' -0
4'
-0
M .O
4' -0
4'
-0
M .O
2' -8
'-8
14'-4"
1'-0"
EXISTING
FFE: 0'-0"
T.O. SLAB: -0'-2"
EXISTING
FFE: 0'-0"
T.O. SLAB: -0'-3"
EXISTING
T.O. SLAB: -0'-7"
@ TRENCH DRAIN
EXISTING
T.O. SLAB: 0'-0"
@ PERIM. (SLOPES
TO TRENCH DRAIN)
EXISTING
T.O. SLAB: 0'-0"
@ PERIM. (SLOPES
TO TRENCH DRAIN)
B6 A3.01
D5 A3.01
M8
M8
M8
1'-0"
MIN.
2'-4"
M8
#5 VERT.
REBAR, TYP.
W- 1
W- 1
1 07
KEY PLAN
Scale: 1/32" = 1'-0"
A6 A1.01
B1 A1.01
B3 A1.01
B6 A1.01
REFLECTED CEILING PLAN GENERAL NOTES
A. REFER TO LEGEND FOR REFLECTED CEILING PLAN SYMBOLS.
B. REFER TO FINISH LEGEND / SCHEDULE AND SPECIFICATIONS FOR CEILING FINISHES AND
SYSTEMS.
C. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BETWEEN REFLECTED CEILING
PLAN AND HVAC / ELECTRICAL / FIRE PROTECTION / PLUMBING DRAWINGS.
D. CENTER GRID IN THE N, S, E, & W DIRECTIONS OF ALL SPACES UNLESS NOTED OR SHOWN
OTHERWISE. CEILING TILE ALONG THE WALL SHALL NOT BE LESS THAN 3".
E.
INSTALL ALL CEILING MOUNTED EQUIPMENT IN THE CENTER OF CEILING TILE, UNLESS
NOTED OR SHOWN OTHERWISE. IF DEVICE IS SHOWN TO ONE SIDE OF TILE (I.E. 2 X 4),
CENTER DEVICE IN THAT HALF OF THE TILE.
F.
COORDINATE CEILING MOUNTED EQUIPMENT SUCH AS PIPES, DUCTWORK, CONDUITS,
DATA, A/V CABLING / WIRING, AND FIXTURE SIZES AND LOCATIONS WITH HVAC / ELECTRICAL
/ FIRE PROTECTION / PLUMBING DRAWINGS.
G. GENERAL CONTRACTOR TO COORDINATE WITH ELECTRICAL DRAWINGS FOR LIGHT
FIXTURE TYPES, QUANTITY, AND LAYOUT.
H.
DAMAGE TO ANY CEILING TILE OR GRID THAT IS SCHEDULED TO BE REMOVED AND
REINSTALLED SHALL BE REPLACED WITH THE SAME PRODUCT BY THE G.C. PRIOR TO
REINSTALLATION.
I. NEW CEILINGS TO BE INSTALLED AT EXISTING CEILING HEIGHT UNLESS NOTED OTHERWISE.
J. ALIGN FACE OF SOFFIT / BULKHEAD WITH FACE OF WALL, BOTH SIDES WHERE APPLICABLE, UNLESS NOTED OTHERWISE.
ACOUSTIC CEILING
SYSTEM, 2X4 OR 2X2
AS SHOWN ON DWG
DRYWALL/PLASTER
SPRINKLER HEAD
2X2 LIGHT FIXTURE
2X4 LIGHT FIXTURE
LINEAR LED FIXTURE
DOWNLIGHT
2X2 EMERGENCY
2X4 EMERGENCY
LINEAR EMERGENCY
DOWNLIGHT EMERGENCY
HVAC SUPPLY DIFFUSER
HVAC RETURN GRILLE
HVAC LINEAR DIFFUSER
RADIANT CEILING PANEL
CABINET UNIT HEATER
S SPEAKER
OS OCCUPANCY SENSOR
FIRE DETECTORF
ACCESS PANEL
CR CORD REEL
CURTAIN TRACK
REFLECTED CEILING PLAN SYMBOLS
EXIT LIGHT WALL MT
EXIT LIGHT CEILING MT
EX.23 EX.24 EX.25 EX.26
EX.F
EX.G
EX.H
EX.J
EX.K
EX.L
EX.M
MEN'S LOCKER RM.
OFFICE
CORRIDOR
TRUCK PARKING
TOILET
107A
OFFICE
W-1
W-1
REFLECTED CEILING PLAN - PARTIAL
Scale: 1/4" = 1'-0"
B6 A1.01
EXISTING CEILING ASSEMBLY
TO REMAIN. REMOVE AND
REINSTALL WHERE REQUIRED
FOR NEW HVAC SYSTEM
ACCESS.
NEW DIFFUSER/GRILLE, REFER
TO HVAC DWGS., TYP.
8'-0"
EX.23 EX.24 EX.25 EX.26
EX.F
EX.G
EX.H
EX.J
EX.K
EX.L
EX.M
MEN'S LOCKER RM.
OFFICE
CORRIDOR
TRUCK PARKING
TOILET
107A
OFFICE
DEMOLITION PLAN - PARTIAL
Scale: 1/4" = 1'-0"
B1 A1.01
M.1
D.1 M.2
3'-4" 2'-8"
EXISTING UTILITY
SERVICE TO REMAIN
D.2D.2
D.2
D.2
DEMOLITION GENERAL NOTES
GN-1 NOTIFY THE ARCHITECT, IN WRITING, IMMEDIATELY UPON DISCOVERY OF ANY
DISCREPANCY AND/OR INCONSISTENCY BETWEEN THE DRAWINGS AND SPECIFICATIONS.
GN-2
THE GENERAL CONTRACTOR SHALL REFER TO SPECIFICATION SECTION 011100 "SUMMARY
OF WORK" FOR A GENERAL DESCRIPTION OF THE SCOPE OF WORK ASSOCIATED WITH
DEMOLITION.
GN-3 WORK SHALL NOT INTERFERE WITH LEGAL FIRE EXITS. ALL CORRIDORS AND STAIRS SHALL
BE MAINTAINED CLEAR AT ALL TIMES.
GN-4
THE GENERAL CONTRACTOR SHALL BEAR RESPONSIBILITY OF CUTTING AND PATCHING OF
EXISTING AND/OR NEW WALLS, FLOORS, ROOFS, ETC. THE GENERAL CONTRACTOR SHALL
BE RESPONSIBLE FOR REVIEWING AND COORDINATING WITH HVAC, ELECTRICAL,
PLUMBING, AND ROOFING DRAWINGS FOR ANY ADDITIONAL DEMOLITION WORK
ASSOCIATED WITH CUTTING & PATCHING.
GN-5
PENETRATIONS, OPENINGS, CHASES, ETC. FOR MECHANICAL, PLUMBING, ELECTRICAL, AND
ROOFING WORK ARE SHOWN FOR COORDINATION PURPOSES ONLY. DIMENSIONS AND
LOCATIONS MUST BE VERIFIED AND COORDINATED WITH OTHER TRADES PRIOR TO
CONSTRUCTION.
GN-6
SEAL ALL OPENINGS CAUSED BY REMOVAL OF EXTERIOR DOORS, WINDOWS, WALLS, ETC.
AT THE END OF EACH SHIFT WITH SECURELY ANCHORED PLYWOOD CLOSURES UNTIL
PERMANENT CLOSURES ARE INSTALLED.
GN-7
ALL EXISTING STRUCTURE, FINISHES, AND EQUIPMENT TO REMAIN SHALL BE PROTECTED
FROM DAMAGE THROUGHOUT THE DURATION OF CONSTRUCTION. EXISTING STRUCTURE,
FINISHES, AND EQUIPMENT DAMAGED OR REMOVED DUE TO DEMOLITION OR NEW WORK
SHALL BE REPAIRED AND/OR PATCHED WITH MATCHING CONSTRUCTION AND FINISHES.
GN-8
WHERE INTERIOR PARTITIONS ARE TO BE REMOVED AND NOT REPLACED, THE GENERAL
CONTRACTOR IS RESPONSIBLE FOR PROVIDING A LEVEL TRANSITION BETWEEN THE TWO
ADJACENT FLOORS AND/OR WALL SURFACES. IN NO CASE SHALL THE SLOPE OF THE
FLOOR TRANSITION BE GREATER THAN 1/16 INCH PER FOOT.
GN-9
NOTED EXISTING AND NEW SURFACES ARE TO BE PREPARED TO RECEIVE NEW FINISHES,
INCLUDING FINISH PATCHING OF NEW AND EXISTING HOLES / VOIDS / CRACKS AND
CLEANING OF SURFACES AS PER MANUFACTURER'S INSTRUCTIONS, ETC.
GN-10
PENETRATIONS, OPENINGS, CHASES, ETC. FOR MECHANICAL, ELECTRICAL, AND/OR
PLUMBING WORK ARE SHOWN FOR COORDINATION PURPOSES. DIMENSIONS OF
OPENINGS/PENETRATIONS AND LOCATIONS MUST BE VERIFIED AND COORDINATED WITH
OTHER TRADES PRIOR TO CONSTRUCTION.
GN-11
THE GENERAL CONTRACTOR SHALL REFER TO THE STRUCTURAL DRAWINGS FOR
REMOVALS OF STRUCTURAL COMPONENTS, INCLUDING PENETRATIONS FROM OTHER
CONTRACTORS' WORK.
GN-12 THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE ARCHITECT AND OWNER FOR
THE EXACT LOCATION OF NEW AND/OR RELOCATED ITEMS.
GN-13 REFER TO DRAWING A0.00 FOR SYMBOLS THAT APPLY TO THIS SHEET AS WELL AS
DEMOLITION DRAWINGS.
DEMOLITION KEYED NOTES
DEMOLITION KEYED NOTES ARE INDICATED ON DRAWINGS WITH A SQUARE.
NOT ALL NOTES LISTED BELOW APPLY TO THIS SHEET.
D. INTERIOR WALL AND FINISH DEMOLITION
WALL CONSTRUCTION:
D.1
CUT OPENING IN MASONRY WALL CONSTRUCTION WHERE INDICATED. INSTALL LINTEL AS
REQUIRED. TOOTH IN BOTH JAMBS OF OPENING WITH FINISHED CONCRETE BLOCKS TO
MATCH EXISTING.
D.2
CUT OPENING IN MASONRY WALL CONSTRUCTION ABOVE CEILING SYSTEM FOR HVAC DUCT
OR LOUVER. INSTALL LINTEL AS REQUIRED IN EXTERIOR WALL OPENINGS. COORDINATE
WITH HVAC EQUIPMENT/DWGS.
G. CEILING DEMOLITION
G.1
CAREFULLY REMOVE A PORTION OF LAY-IN CEILING AND SUSPENSION SYSTEM AS REQUIRED
FOR NEW WORK. HATCH INDICATES APPROXIMATE SIZE AND LOCATION OF REMOVALS.
COORDINATE WITH CONSTRUCTION DRAWINGS. STORE SUSPENSION SYSTEM AND TILE IN
SAFE PLACE FOR REINSTALLATION AT COMPLETION OF WORK. EXISTING SUSPENSION
SYSTEM AND TILES TO BE REWORKED TO ACCOMMODATE NEW CONSTRUCTION. GC IS
RESPONSIBLE FOR REPLACING ANY DAMAGED TILE OR GRID TO MATCH EXISTING.
H. EXTERIOR DEMOLITION
H.1
REMOVE A PORTION OF EXTERIOR WALL CONSTRUCTION WHERE INDICATED. EXISTING
COLUMNS AND BEAMS TO REMAIN. SHORE EXISTING FASCIA CONSTRUCTION AS NEEDED
UNTIL NEW WALL CONSTRUCTION IS IN PLACE.
K. FLOOR DEMOLITION
K.1
REMOVE VINYL TILE, BASE, AND MASTIC COMPLETE. REMOVE REMAINING MASTIC [WITH
SOLVENT ACCEPTABLE TO ARCHITECT AND NEW FLOORING MANUFACTURER] [BY BEAD
BLASTING]. PREPARE SLAB FOR NEW FINISH AS SCHEDULED AND IN MANNER REQUIRED BY
NEW FINISH MANUFACTURER.
M. MISCELLANEOUS DEMOLITION
M.1
FLAMMABLE STORAGE CABINET: DISCONNECT PVC VENT, RELOCATE CABINET AND
EXTEND/RECONNECT PVC VENT PIPE IN NEW LOCATION. EXISTING EXTERIOR WALL
PENETRATION TO REMAIN.
M.2 REMOVE WINDOW A/C UNIT IN WALL AND TURN OVER TO OWNER.
N. COORDINATION WITH ABATEMENT & MEP TRADES DEMOLITION
N.1 HVAC CONTRACTOR TO REMOVE UNIT VENTILATOR AND FIN TUBE COVER. STORE ON SITE
FOR REINSTALLATION AFTER [ABATEMENT] WORK HAS BEEN COMPLETED.
N.2 HVAC CONTRACTOR TO REMOVE UNIT VENTILATOR. PATCH EXG. FLOOR/ CONCRETE SLAB
SCHEDULED TO REMAIN AS REQUIRED BY NEW FINISHES.
N.3
AFTER FLOOR DRAIN REMOVAL BY PLUMBING CONTRACTOR, SCARIFY CONCRETE SLAB
SURFACE AT AREA SLOPED TO FLOOR DRAIN AND FILL DEPRESSION WITH SELF-LEVELING
CEMENTITIOUS UNDERLAYMENT, UP TO LEVEL WITH FINISHED SLAB SURFACE.
N.4 AFTER [WATER CLOSET] [LAVATORY] REMOVAL BY PLUMBING CONTRACTOR, PATCH
REMAINING SURFACES [TO MATCH EXISTING] [TO RECEIVE NEW FINISH AS SCHEDULED].
07/14/2026DRAWING DATE:
DIGITAL REPRODUCTIONS OF THESE
DRAWINGS SHALL NOT BE POSTED TO WEB
SITES WITHOUT THE DIRECT WRITTEN
PERMISSION OF THE ARCHITECT.
IT IS A VIOLATION OF THE STATE EDUCATION
LAW FOR ANY PERSON, UNLESS UNDER THE
DIRECTION OF A LICENSED ARCHITECT TO
ALTER THIS DOCUMENT IN ANY WAY.
ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH THE DESCRIPTION OF THE
ALTERATION AND SIGNATURE AND DATE.
COPYRIGHT ©.
M A
D
IS
O N
C O
U N
TY
H
IG
H
W
AY
G A
R A
G E
O
FF
IC
E
A R
E A
R E
N O
VA
TI
O N
N O
R
TH
C O
U R
T
ST
R E
ET
W
AM
PS
VI
LL
E , N
Y
A3.01
SCALE:
DRAWING TITLE:
As Noted
WALL SECTIONS &
DETAILS
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
SECTION DETAIL
Scale: 3/4" = 1'-0"
B6 A3.01
T.O. CMU / T.O. STEEL
9'-4"
LEVEL 1
0'-0"
M.O. SILL
3'-4"
M.O. HEAD
7'-4"
2' -8
C O
U R
S E
S
4' -0
C O
U R
S E
S
2' -0
(3 C
O U
R S
E S
9' -4
(1
C
O U
R S
E S
T.O. EXIST. CMU (EXT. WALL)
14'-0"
'-0
E X
IS
T.
C O
U R
S E
S
8" CMU WALL, REINFORCED w/ VERT. #5 REBAR
@ 48" O.C. (CENTERED) AND HORIZ. JOINT REINF.
(NOT SHOWN) PER SPECS.
H.M. WINDOW
BOND BEAM LINTEL, L-2
ACT-1 SUSP. ACOUSTICAL CEILING SYSTEM
8' -0
" C E
IL
IN
G H
E
IG
H T
PREFIN. METAL ROOFING
SYSTEM
T.O. CONC. CURB
0'-8"
T.O. EXIST. FLR.
VARIES
8"
EXISTING EXTERIOR TRANSLUCENT WALL PANEL
SYSTEM TO REMAIN
EXISTING EXTERIOR CMU WALL SYSTEM
TO REMAIN
1'-0"
BOND BEAM w/ (2) #4 REBAR @ SILL
CONT. NON-SWELLING WATERSTOP
8" WIDE x 8" HIGH BOND BEAM w/ (2) #4 REBAR CONTINUOUS
SEALED CEMENTITIOUS TOPPING
OVER SHOTBLASTED EXIST. 6" +/-
CONC. SLAB ON GRADE
CONT. PREFIN. METAL CLOSURE STRIP
PREFIN. METAL CLOSURE TRIM
w/ DRIP EDGE
PREFIN. METAL OR PVC TRIM
CLOSURE
2x6 F.R.T. WOOD BLOCKING, CONT.
BETWEEN TRUSSES, TYP.
3/4" T&G FIRE TREATED
PLYWOOD, TYP.
DESIGN-DELEGATED
PREFABRICATED CFMF
TRUSSES @ 24" O.C.
DRILL & EPOXY #5 REBAR @ 48" O.C. INTO
EXISTING SLAB w/ 5" MIN. EMBED
CONT. 8" WIDE CONCRETE CURB, REINFORCED w/
(2) #4 REBAR CONTINUOUS. INSTALL (2) 2'-0" x 2'-0"
L-SHAPED CORNER BARS AT WALL CORNER.
8' -8
" V .I.
F.
HVAC MANUF. PREFAB.
MOUNTING BRACKET, POWDER
COATED. MOUNT TO CONCRETE
BLOCK WITH MIN. OF (4) 3/8" DIA.
STAINLESS STEEL HEX-HEAD
SLEEVE ANCHORS (HILTI HLC
OR EQ.) WITH 1.5" EMBEDMENT.
PROVIDE A MIN. OF (2)
ANCHORS IN THE PROVIDED
ANCHOR HOLES IN THE TOP
HORIZONTAL PORTION AND (1)
ANCHOR IN THE PROVIDED
ANCHOR HOLES NEAR THE
BOTTOM OF EACH OF THE TWO
VERTICAL LEGS OF THE
BRACKET. REFER TO HVAC
DWGS.
HVAC UNIT, REFER TO HVAC
DWGS.
REMOVE PORTION OF METAL PANEL
TO ALLOW BRACKET TO BE
DIRECTLY MOUNTED TO EXISTING
CONCRETE BLOCK. TRIM AROUND
PERIMETER OF FRAME WITH
MATCHING METAL TRIM.
PREFIN. .040" METAL FLASHING
ABOVE & BELOW FRAME, TYP.
15# FELT PAPER
UNDERLAYMENT, TYP. 362S162-43 CONT. BOTTOM CHORD
BRIDGING AT/NEAR MIDSPAN.
FASTEN TO EACH TRUSS AND AT
ENDS W/ (2) #10 SCREWS
12 GA. GALV. BYPASS SLIDE CLIP CONNECTOR
(SIMPSON SC32 OR EQ.). FASTEN TO CFMF TRUSS
CHORD W/ (2) #10 SCREWS. FASTEN TO CMU WALL
W/ (2) 1/4" DIA. TAPCONS W/ 1 1/4" EMBED, TYP.
EVERY OTHER TRUSS, TOP & BOTTOM.
362S162-43 CONT. DIAG. BRACING.
FASTEN TO EACH TRUSS W/ (2) #10
SCREWS AND FASTEN TO CMU WALL
BOTH ENDS W/ GALV. L3x3x12 GA. x 5"
LONG CLIP (SIMPSON RCA335/97 OR
EQ.). FASTEN BRACE TO CLIP W/ (4)
#10 SCREWS. FASTEN CLIP TO CMU
WALL W/ (2) 1/4" DIA. TAPCONS W/ 1
1/4" MIN. EMBED.
FASTEN EACH TRUSS TO STEEL BEAM
W/ GALV. L4x2x12 GA. LLV x 3 1/2" LONG
CLIP (CLARK DIETRICH T973 OR EQ.).
FASTEN TO TRUSS CHORD WEB W/ (4)
#10 SCREWS. FASTEN TO BEAM TOP
FLANGE W/ (2) #12 SCREWS.
W6x12 BEAM CONTINUOUS. BEAR AND
ANCHOR TO CMU AT BOTH ENDS AND AT
INTERIOR SUPPORT PIER PER TYPICAL
BEAM BEARING DETAIL ON A5.02.
EX.23 EX.24 EX.25 EX.26
EX.F
EX.G
EX.H
EX.J
EX.K
EX.L
EX.M
MEN'S LOCKER RM.
OFFICE
CORRIDOR
TRUCK PARKING
TOILET
107A
OFFICE
FLOOR LEVELING PLAN - PARTIAL
Scale: 1/4" = 1'-0"
B3 A3.01
KEYED FLOOR FINISH NOTES
PREPARE EXISTING SLAB BY SHOT BLASTING. NSTALL CEMENTITIOUS TOPPING TO BRING FINISH FLOOR TO ELEVATIONS INDICATED. SLOPE COATING IN AREAS INDICATED TO MEET EXISTING FLOOR ELEVATIONS. DO NOT EXCEED 1:20 SLOPE.
PROVIDE LEVEL AREA AT DOORWAYS AS NOTED. WHERE NEEDED, INSTALL TOPPING IN SECTIONS BASED ON TOPPING THICKNESS RESTRICTIONS AND NEED TO EXTEND BAG MIX WITH WASHED STONE AGGREGATE FOR THICKER PLACEMENTS.
CLEAN SURFACE AND SEAL TOPPING NEAR END OF CONSTRUCTION PERIOD. STRICTLY FOLLOW APPROVED TOPPING
MANUFACTURERS INSTALLATION GUIDELINES.
EXISTING
FFE: 0'-0"
T.O. SLAB: -0'-2"
EXISTING
FFE: 0'-0"
T.O. SLAB: -0'-3"
EXISTING
T.O. SLAB: -0'-7"
@ TRENCH DRAIN
EXISTING
T.O. SLAB: 0'-0"
@ PERIM. (SLOPES
TO TRENCH DRAIN)
EXISTING
T.O. SLAB: 0'-0"
@ PERIM. (SLOPES
TO TRENCH DRAIN)
LEVEL PORTION AT DOOR
CLEARANCE, TYP. (FFE: 0'-0")
5' -0
M
IN
5'-0" MIN.
4' -0
M
IN
EXISTING
FFE: 0'-0"
T.O. SLAB: VARIES
SLOPE TO MEET EXISTING
T.O. SLAB, TYP.
SECTION DETAIL
Scale: 3/4" = 1'-0"
D5 A3.01
T.O. CMU
9'-4"
PREFIN. METAL ROOFING SYSTEM
PREFIN. METAL CLOSURE TRIM w/ DRIP EDGE
3/4" T&G FIRE TREATED PLYWOOD
CFMF TRUSSES @ 24" O.C.
3/4" T&G FIRE TREATED PLYWOOD
FRP PANEL SYSTEM WITH PERIMETER
TRIM AND EXPOSED FASTENERS
EXISTING CMU WALL BEYOND
FASTEN EACH TRUSS TO STEEL BEAM (BEYOND) W/
GALV. L4x2x12 GA. LLV x 3 1/2" LONG CLIP (CLARK
DIETRICH T973 OR EQ.). FASTEN TO TRUSS CHORD
WEB W/ (4) #10 SCREWS. FASTEN TO BEAM TOP
FLANGE W/ (2) #12 SCREWS.
W6x12 BEAM (BEYOND). BEAR
AND ANCHOR TO CMU AT BOTH
ENDS AND AT INTERIOR
SUPPORT PIER PER TYPICAL
BEAM BEARING DETAIL ON A5.02.
8" CMU WALL, REINFORCED w/ VERT. #5
REBAR @ 48" O.C. (CENTERED) AND HORIZ.
JOINT REINF. (NOT SHOWN) PER SPECS.
362S162-43 CONT. BOTTOM
CHORD BRIDGING AT/NEAR
MIDSPAN. FASTEN TO EACH
TRUSS AND AT ENDS W/ (2)
#10 SCREWS
EXISTING MASONRY WALL
TO REMAIN
8" WIDE x 8" HIGH BOND BEAM w/ (2) #4 CONT.
600T125-43 TRACK, TYP. TOP & BOT.
600S162-43 STUDS 16" O.C. FASTEN TO
TRACKS W/ #10 SCREW EACH FACE.
600S162-43 BLOCKING & DIAG. BRACE
24" O.C. IN END BAY
FASTEN TRACK TO BOND BEAM W/ 1/4" DIA. TAPCONS
(STAGGERED) 16" O.C. W 1 1/4" MIN. EMBED.
L5x3x1/4 LLV x 10" LONG AT BOT.
CHORD BRIDGING. FASTEN TO
CMU WALL W/ (2) 1/2" DIA. SLEEVE
ANCHORS (HILTI HLC OR EQ.) 8"
O.C. W/ 1 1/2" MIN. EMBED.
SLOPING CONT. L5x3x1/4 LLV.
FASTEN TO CMU WALL W/ 1/2"
DIA. SLEEVE ANCHORS (HILTI
HLC OR EQ.) 24" O.C. W/ 1 1/2"
MIN. EMBED.
#10 SELF-DRILLING SCREWS
@ 6" O.C.
#10 SELF-DRILLING SCREWS @ 6" O.C. (STAGGERED)
PLAN DETAIL
Scale: 3/4" = 1'-0"
D4 A3.01
EXISTING WINDOW
ASSEMBLY TO REMAIN
USE FINISH CMU UNIT AT
END OF WALL, TYP.
CONT. .050" PREFIN.
ALUM. FLASHING TRIM AT
END OF BLOCK WALL,
TYP.
EXISTING WALL, TYP.
1'-0" MIN.
ANCHOR WALL END TO EX.
CMU WALL ABOVE AND
BELOW EX. WINDOW PER
TYPICAL DETAIL ON A5.02.
#5 VERT. WALL
REINFORCING. GROUT
CORES SOLID FULL HEIGHT.
TYP. LOUVER DETAIL
Scale: 3/4" = 1'-0"
E5 A3.01
LOUVER, REFER TO HVAC
DWGS.
EXISTING WALL ASSEMBLY
REMOVE PORTION OF METAL
PANEL TO INSTALL LOUVER. TRIM
AROUND PERIMETER OF LOUVER
WITH MATCHING METAL TRIM.
PREFIN. .040" METAL
FLASHING ABOVE & BELOW
FRAME, TYP.
NOTE: SEE KEYED NOTES ON PLAN FOR GALV.
STEEL LINTEL OVER LOUVER OPENING
A
2" AS SCHD. 2"
A S
S C
H D
4"
DOOR FRAMES
1/4" = 1'-0"
A4 A5.01
G
8" 8"VARIES
9" 2'
-9
3' -6
DOOR TYPES
1/4" = 1'-0"
A5 A5.01
1/4" CLEAR TEMPERED SAFETY
GLASS
MARK DESCRIPTION DATE
Issued for Construction
07/14/2026DRAWING DATE:
DIGITAL REPRODUCTIONS OF THESE
DRAWINGS SHALL NOT BE POSTED TO WEB
SITES WITHOUT THE DIRECT WRITTEN
PERMISSION OF THE ARCHITECT.
IT IS A VIOLATION OF THE STATE EDUCATION
LAW FOR ANY PERSON, UNLESS UNDER THE
DIRECTION OF A LICENSED ARCHITECT TO
ALTER THIS DOCUMENT IN ANY WAY.
ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH THE DESCRIPTION OF THE
ALTERATION AND SIGNATURE AND DATE.
COPYRIGHT ©.
M A
D
IS
O N
C O
U N
TY
H
IG
H
W
AY
G A
R A
G E
O
FF
IC
E
A R
E A
R E
N O
VA
TI
O N
N O
R
TH
C O
U R
T
ST
R E
ET
W
AM
PS
VI
LL
E , N
Y
A5.01
SCALE:
DRAWING TITLE:
As Noted
DOOR & WINDOW
SCHEDULE
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
DOOR SCHEDULE
DOOR FRAME ASSEMBLY HDWR
SET # KEYED NOTES
DOOR NO. TYPE WIDTH HEIGHT THICK. MATERIAL GLASS TYPE HEAD DETAIL JAMB DETAIL WALL DEPTH FINISH LABEL
FIRST FLOOR
107 F 3'0" 7'0" 1 3/4" HM GL-1 HM B4/A5.01 B5/A5.01 7 5/8" PT-2 - 01 1
GENERAL NOTES
A. REFER TO SPECIFICATION SECTION 088000 'GLAZING' FOR ALL GLAZING TYPES.
B. FIELD VERIFY DEPTHS OF EXISTING WALLS SCHEDULED TO RECEIVE NEW DOORS / FRAMES.
C. NOTE: FRAME DEPTHS = WALL DEPTH + 1", UNLESS OTHERWISE NOTED.
KEYED NOTES
1. PROVIDE 4" HIGH FRAME AT HEAD OF DOOR (TO MEET BLOCK COURSING).
FINISH LEGEND
FINISH MANUFACTURER STYLE COLOR NOTES
ACOUSTICAL CEILING TILE
ACT-1 USG MARS ACOUSTICAL PANELS, 2' X 2' WHITE SLT EDGE PROFILE (ANGLED TEGULAR) w/ CLIMAPLUS PERFORMANCE 15/16" GRID, WHITE.
CONCRETE (FINISHED)
CONC-1 CONCRETE SEALER CLEAR
PAINT
PT-1 (FIELD) SHERWIN WILLIAMS MATCH EXISTING MATCH EXISTING
PT-2 (DOOR AND FRAME) SHERWIN WILLIAMS MATCH EXISTING MATCH EXISTING
--- NO FINISHES
EXG EXISTING FINISH TO REMAIN
EXPOSED EXPOSED CEILING
FINISH SCHEDULE
ROOM
NO. ROOM NAME FLOOR BASE NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING KEYED
NOTESFINISH FINISH FINISH FINISH FINISH FINISH FINISH
FIRST FLOOR
107A OFFICE CONC-1 - PT-1 PT-1 PT-1 PT-1 ACT-1
GENERAL NOTES
A. SEE INTERIOR ELEVATIONS, SECTIONS, REFLECTED CEILING PLANS, CONSTRUCTION AND FINISH FLOOR PLANS FOR FINISH LOCATIONS.
B. REFER TO REFLECTED CEILING PLANS FOR CEILING AND SOFFIT HEIGHTS.
KEYED NOTES
1.
NOTE: THIS FINISH SCHEDULE (DUMMY) POPULATES ONLY THE SPACE NAME AND
NUMBER FROM THE SPACE TAG OBJECTS. INPUT ALL OTHER FIELDS MANUALLY.
FINISH GENERAL NOTES
A.
NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN DRAWINGS, SCHEDULES AND
SPECIFICATIONS. REFER TO SUPPLEMENTARY GENERAL CONDITIONS FOR FURTHER
INFORMATION REGARDING CONSTRUCTION DOCUMENTS.
B. PAINT ALL NEW [INTERIOR/EXTERIOR] EXPOSED [LINTELS, TRIM, ETC..].LINTELS TO BE
[PAINT COLOR].
C. DOOR FRAMES TO BE PT-2 UNLESS NOTED OTHERWISE.
WALL TYPE
PER PLAN
GROUT JAMB BLOCK
CORE SOLID
FRAME ANCHORS PER
SPECIFICATION
SEALANT ALL AROUND BOTH
SIDES OF FRAME (TYP.)
HOLLOW METAL FRAME
2" 1 4"
834"
DOOR JAMB DETAIL
1 1/2" = 1'-0"
B5 A5.01
WALL TYPE
PER PLAN
HOLLOW METAL FRAME
SEALANT ALL AROUND BOTH
SIDES OF FRAME (TYP.)
GROUT CMU VOID SOLID
STEEL LINTEL
4" 1 4"
834"
DOOR HEAD DETAIL
1 1/2" = 1'-0"
B4 A5.01
NOTE: WINDOW HEAD DETAIL SIM, WITH 2" FRAME
INTERIOR WINDOW TYPES
1/4" = 1'-0"
A6 A5.01
W-1
2" 3'-8" 2"
2" 3'
-8
2"
4' -0
4'-0"
3' -4
HOLLOW METAL FRAME. PAINT
PT-2 BOTH SIDES, TYP.
1/4" CLEAR TEMPERED SAFETY
GLASS
B4 A5.01
B5 A5.01
SIM.
07/14/2026DRAWING DATE:
DIGITAL REPRODUCTIONS OF THESE
DRAWINGS SHALL NOT BE POSTED TO WEB
SITES WITHOUT THE DIRECT WRITTEN
PERMISSION OF THE ARCHITECT.
IT IS A VIOLATION OF THE STATE EDUCATION
LAW FOR ANY PERSON, UNLESS UNDER THE
DIRECTION OF A LICENSED ARCHITECT TO
ALTER THIS DOCUMENT IN ANY WAY.
ALTERATIONS MUST HAVE THE SEAL AFFIXED
ALONG WITH THE DESCRIPTION OF THE
ALTERATION AND SIGNATURE AND DATE.
COPYRIGHT ©.
M A
D
IS
O N
C O
U N
TY
H
IG
H
W
AY
G A
R A
G E
O
FF
IC
E
A R
E A
R E
N O
VA
TI
O N
N O
R
TH
C O
U R
T
ST
R E
ET
W
AM
PS
VI
LL
E , N
Y
A5.02
SCALE:
DRAWING TITLE:
As Noted
STRUCTURAL NOTES &
DETAILS
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
SHOWN ON PLAN AS
W = BEARING PLATE WIDTH
SEE BEARING PLATE SCHEDULE
W+1"
TYP BEAM BEARING ON MASONRY WALL DETAIL
GROUT OR MORTAR CMU CORES
SOLID MIN. (2) COURSES BELOW &
1'-4" WIDE BELOW BEARING.
MASON IN POCKET AFTER
BEAM ERECTION
NOTES: 1. IF BEAM BEARING OCCURS AT A BOND BEAM, DO NOT INTERRUPT BOND
BEAM REINFORCING. PROVIDE HOLES IN BEAM WEB AS REQUIRED TO RUN
BOND BEAM REINFORCING CONTINUOUS THROUGH BEAM BEARING(S)
1/2"x5"x7" BEARING PLATE
ON 3/4" NON-SHRINK GROUT
(2) 1/2" DIA. GRADE 36 ANCHOR RODS
W/ 12" MIN. EMBED.
WF BEAM
3/16 3/16
REINFORCED CMU WALL SCHEDULE
WALL
LOCATION WALL TYPE
OFFICE AREA
EXPANSION
ALL MASONRY
WALLS
WALL
THICKNESS
(NOMINAL)
VERTICAL REINFORCING SIZE & SPACING
FIELD END OF WALL (NOTE 2a)
8" #5 @ 48"
(1) #5 FOR M.O. < 4',
(2) #5 @ 8" FOR 4'<M.O.<6'
"FIELD" REINFORCING, TYP.
SEE SCHEDULE FOR SIZE &
SPACINGNOTES: 1. GENERAL:
a) ALL CMU WALLS SHOWN ON STRUCTURAL DRAWINGS ARE STRUCTURAL WALLS (LOAD-BEARING WALLS, SHEAR WALLS, RESIST OUT-OF-PLANE WIND OR SEISMIC LOADS, FIREWALLS, OR WALLS THAT ARE
STRUCTURAL FOR OTHER REASONS).
b) DO NOT LOCATE CMU CONTROL JOINTS WITHIN 16" OF A WALL OPENING JAMB IF A MASONRY LINTEL IS
INDICATED, U.N.O.
c) REINFORCING LAP LENGTHS SHALL BE PER THE LAP SPLICE SCHEDULE.
2. VERTICAL REINFORCING:
a) START "END OF WALL" REINFORCING WITHIN 16" OF OPENING JAMBS WITH END-BEARING STEEL LINTELS AND WITHIN 8" OF JAMBS WITH MASONRY LINTELS OR NON-END-BEARING STEEL LINTELS, WALL ENDS, CORNERS, AND EACH SIDE OF CONTROL JOINTS AND EXPANSION JOINTS. SEE "CASE 1" AND "CASE 2" DETAILS
BELOW FOR VERTICAL WALL REINFORCING AT WALL OPENING JAMBS.
b) VERTICAL REINFORCING SHALL BE CENTERED IN GROUTED CORES, U.N.O.
c) UNLESS NOTED OR DETAILED OTHERWISE, PROVIDE ONLY ONE VERTICAL REINFORCING BAR PER CORE.
d) VERTICAL REINFORCING IS FOR FULL HEIGHT OF WALL, U.N.O.
e) ALL VERTICAL BARS SHALL HAVE MATCHING DOWELS DRILLED AND EPOXIED 5 INCHES MINIMUM INTO THE
EXISTING CONCRETE SLAB ON GRADE.
3. HORIZONTAL REINFORCING:
a) MINIMUM REINFORCING AWAY FROM WALL OPENINGS:
1) BELOW FLOOR LEVELS, ROOF LEVELS, AND TOP OF WALLS - (2) #4'S IN KNOCK-OUT BLOCKS.
2) BELOW GRADE - LADDER-TYPE JOINT REINF. W/ 9 GA. SIDE WIRES, 8" O.C.
3) ABOVE GRADE - LADDER-TYPE JOINT REINF. W/ 9 GA. SIDE WIRES, 16" O.C.
b) REINFORCING ABOVE WALL OPENINGS: SEE APPLICABLE LINTEL SCHEDULE. REINFORCEMENT TO EXTEND GREATER OF 24" AND 40db BEYOND OPENING JAMBS, U.N.O.
c) REINFORCING BELOW WALL OPENINGS: REINFORCEMENT TO EXTEND GREATER OF 24" AND 40db BEYOND
OPENING JAMBS, U.N.O.
1) M.O.<8': 8"H KNOCK-OUT BLOCK W/ (2) #4 CONT.
2) 8'<M.O.<12': 8"H KNOCK-OUT BLOCK W/ (2) #5 CONT.
3) 12'<M.O.<18': 16"H KNOCK-OUT BLOCK W/ (2) #5 CONT. TOP & BOTTOM
MASONRY OPENING (M.O.) WIDTH
JA
M
B"FIELD" SPC.
SEE SCHED.
"FIELD" SPC.
SEE SCHED.
"END OF WALL" REINFORCING.
SEE SCHEDULE FOR QTY, SIZE &
SPACING
CASE 1: BOND BEAM LINTEL
MASONRY OPENING (M.O.) WIDTH
JA
M
B"FIELD" SPC.
SEE SCHED.
"FIELD" SPC.
SEE SCHED.
"END OF WALL" REINFORCING.
SEE SCHEDULE FOR QTY, SIZE &
SPACING
CASE 2: END-BEARING STEEL LINTEL
"FIELD" REINFORCING, TYP.
SEE SCHEDULE FOR SIZE &
SPACING
GROUT CORE BELOW LINTEL
BEARING & REINF. W/ (1) "END
OF WALL" BAR
WALL
GROUTED
SOLID?
NO
MASONRY LAP SPLICE SCHEDULE
BAR
SIZE
CMU
SIZE
LAP SPLICE LENGTH (MINIMUM)
CENTERED BARS OFFSET BARS
#4 22"16"
8"
10"
12"
8"
10"
12"
8"
10"
12"
#5
#6
22"16"
22"16"
36"20"
36"16"
36"16"
64"38"
64"24"
30" 64"
8"
10"
12"
#7 34"
40"
8"
10"
12"
#8 79"
54"
61"
50"
[M]
[M]
[M]
[M]
[M]
[M]
NOTES: 1. SCHEDULED VALUES ARE VALID FOR MASONRY HAVING NET AREA
COM…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .