REF_2_3_IHT_Heat_Exchanger_SKT012125_Revised_23_Jan_25.pdf
PDF 177 KB Posted
- Solicitation number
- 1333MK25Q0079
About this file
This document is a Request for Quote (RFQ) for replacing main motor heat exchangers on the NOAA Ship Pisces, issued by the National Oceanic and Atmospheric Administration (NOAA) Office of Marine & Aviation Operations. The solicitation (Number 1333MK25Q0079) is a 100% small business set-aside under NAICS code 336611 with a size standard of 1,300 employees, targeting ship building and repairing services. The period of performance is May 23-27, 2025, with the ship located in Port of Kodiak, Alaska, and includes two Contract Line Item Numbers (CLINs): one for primary heat exchanger replacement and a second reserved for potential growth work or additional items.
Key submission requirements include providing a detailed quote with specific documentation such as SAM registration, liability insurance, three references for similar heat exchanger work, itemized cost breakdown, and manufacturer authorization letters. Quotes must be electronically submitted to Christopher.Baker@NOAA.gov by April 30, 2025, at 12:00 PM Eastern Time. The government will award a firm-fixed-price contract based on best value considerations including capability, availability, and pricing. Vendors must be registered in the SAM database, and all questions must be submitted in writing by April 25, 2025, at 12:00 PM ET.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text
COIL ASSEMBLY
AutoCAD SHX Text
UNLESS OTHERWISE SPECIFIED.
AutoCAD SHX Text
ENGINEERING SPECIFICATIONS (11-6.00)
AutoCAD SHX Text
LIMITATIONS OUTLINED IN THE STANDARD
AutoCAD SHX Text
WITH STANDARD FACTORY TOLERANCE
AutoCAD SHX Text
TOLERANCES WILL BE IN ACCORDANCE
AutoCAD SHX Text
BORNHEIMER
AutoCAD SHX Text 1-21-25
AutoCAD SHX Text
SKT012125
AutoCAD SHX Text
31.00 X 71.75 4-ROW
AutoCAD SHX Text
2-PASS MTCL
AutoCAD SHX Text
ASME CODE STAMP
AutoCAD SHX Text R
AutoCAD SHX Text 54623
AutoCAD SHX Text
COON VALLEY, WI
AutoCAD SHX Text
TRANSFER, INC.
AutoCAD SHX Text
INDUSTRIAL HEAT
AutoCAD SHX Text
THIS DRAWING IS THE PROPERTY OF IHT
AutoCAD SHX Text
AND IS PROPRIETARY IN GENERAL AND
AutoCAD SHX Text
IN DETAIL. IT SHALL NOT BE COPIED OR
AutoCAD SHX Text
ITS CONTENTS REVEALED TO OUTSIDE
AutoCAD SHX Text
PARTIES WITHOUT THE WRITTEN CONSENT
AutoCAD SHX Text
OF IHT.
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHKD
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SIMILAR TO
AutoCAD SHX Text
STD ENGR SPEC
AutoCAD SHX Text
FIRST USED ON
AutoCAD SHX Text
ASSY NO.
AutoCAD SHX Text
ALL DIMENSIONS IN INCHES
AutoCAD SHX Text
DO NOT SCALE DRAWING
AutoCAD SHX Text
EXT
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
PART NAME
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
DRAWING, PART OR
AutoCAD SHX Text
MATERIAL NO.
AutoCAD SHX Text
DRG
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
NONE
AutoCAD SHX Text
SKT012125
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
REVISION HISTORY
AutoCAD SHX Text
REV
AutoCAD SHX Text
TYP
AutoCAD SHX Text
FIN LENGTH
AutoCAD SHX Text
CERTIFIED BY
AutoCAD SHX Text Coon Valley, WI 54623
AutoCAD SHX Text
YEAR
AutoCAD SHX Text X39000021-01
AutoCAD SHX Text
MFG. P/N
AutoCAD SHX Text
NDUSTRIAL
AutoCAD SHX Text I
AutoCAD SHX Text M.A.W.P.
AutoCAD SHX Text M.A.E.W.P.
AutoCAD SHX Text
MFG. S/N
AutoCAD SHX Text M.D.M.T.
AutoCAD SHX Text
RANSFER
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text
EAT
AutoCAD SHX Text
AutoCAD SHX Text I
AutoCAD SHX Text
NC.
AutoCAD SHX Text
IHT
AutoCAD SHX Text
PSI AT
AutoCAD SHX Text
PSI AT
AutoCAD SHX Text %%dF AT
AutoCAD SHX Text %%dF
AutoCAD SHX Text
PSI
AutoCAD SHX Text %%dF
AutoCAD SHX Text 2.50-150# R.F.
AutoCAD SHX Text
FLANGES
AutoCAD SHX Text L
AutoCAD SHX Text C
AutoCAD SHX Text L
AutoCAD SHX Text C
AutoCAD SHX Text
CERTIFIED BY
AutoCAD SHX Text Coon Valley, WI 54623
AutoCAD SHX Text
YEAR
AutoCAD SHX Text X39000021-01
AutoCAD SHX Text
MFG. P/N
AutoCAD SHX Text
NDUSTRIAL
AutoCAD SHX Text I
AutoCAD SHX Text M.A.W.P.
AutoCAD SHX Text M.A.E.W.P.
AutoCAD SHX Text
MFG. S/N
AutoCAD SHX Text M.D.M.T.
AutoCAD SHX Text
RANSFER
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text
EAT
AutoCAD SHX Text
AutoCAD SHX Text I
AutoCAD SHX Text
NC.
AutoCAD SHX Text
IHT
AutoCAD SHX Text
PSI AT
AutoCAD SHX Text
PSI AT
AutoCAD SHX Text %%dF AT
AutoCAD SHX Text %%dF
AutoCAD SHX Text
PSI
AutoCAD SHX Text %%dF
AutoCAD SHX Text .75
AutoCAD SHX Text 35.12
AutoCAD SHX Text 72.75
AutoCAD SHX Text 4.00
AutoCAD SHX Text 11.00
AutoCAD SHX Text 5.50
AutoCAD SHX Text
1.00-8 UNC FOR LIFTING 2-PLACES
AutoCAD SHX Text
.25 NPT DRAINS
AutoCAD SHX Text
FOR DRIP TRAY
AutoCAD SHX Text
2-PLACES
AutoCAD SHX Text
AIR
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
DESIGN CONDITIONS:
AutoCAD SHX Text
TEST INFORMATION:
AutoCAD SHX Text
CONSTRUCTION TO BE IN ACCORDANCE WITH ASME
AutoCAD SHX Text
SHALL BE QUALIFIED IN ACCORDANCE WITH ASME CODE.
AutoCAD SHX Text
INSPECTOR MAY BE REQUIRED.
AutoCAD SHX Text
TUBE SIDE - 100 PSIG @ 200 %%DF.
AutoCAD SHX Text
PRESSURE - 200 PSIG AIR UNDER WATER
AutoCAD SHX Text
LEAK - 100 PSIG AIR UNDER WATER
AutoCAD SHX Text
MIN. DESIGN METAL TEMP. 20 %%DF.
AutoCAD SHX Text
BOILER & PRESSURE VESSEL CODE; SECTION VIII, DIV. 1.
AutoCAD SHX Text
WHERE INDICATED, WELDERS & WELDING PROCEDURES USED
AutoCAD SHX Text
FIT-UP & FINAL WELD INSPECTION BY THE AUTHORIZED
AutoCAD SHX Text 4.
AutoCAD SHX Text 3.
AutoCAD SHX Text 2.
AutoCAD SHX Text 1.
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
STUD - ASME SA-193 B8 316 STN. STL.
AutoCAD SHX Text
PIPE - ASME SB-466 C70600 90-10 CU-NI
AutoCAD SHX Text
HEADER - ASME SB-171 C70600 90-10 CU-NI
AutoCAD SHX Text
FLANGE - ASME SB-402/171 90-10 CU-NI
AutoCAD SHX Text
TUBESHEET - ASME SB-171 C70600 90-10 CU-NI
AutoCAD SHX Text
TUBE - ASME SB-111 C70600 70-30 CU-NI
AutoCAD SHX Text
MATERIAL SPECIFICATIONS:
AutoCAD SHX Text
NUT - SA-194 GR-8 316 STN. STL.
AutoCAD SHX Text
SECTION A-A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text 1.00
AutoCAD SHX Text
TYP
AutoCAD SHX Text 17.56
AutoCAD SHX Text 7.75
AutoCAD SHX Text 15.50
AutoCAD SHX Text 6.25
AutoCAD SHX Text
.38 DIA.
AutoCAD SHX Text
24-HOLES
AutoCAD SHX Text
.31-18 UNC, .50 DEEP
AutoCAD SHX Text
36-HOLES
AutoCAD SHX Text
11 - 6.00 SPACES = 66.00
AutoCAD SHX Text 73.50
AutoCAD SHX Text 3.75
AutoCAD SHX Text 3.75
AutoCAD SHX Text .38
AutoCAD SHX Text
TYP
AutoCAD SHX Text
REF
AutoCAD SHX Text
8 - 4.16 SPACES = 33.25
AutoCAD SHX Text 16.62
AutoCAD SHX Text 71.75
AutoCAD SHX Text
FIN
AutoCAD SHX Text
REF
AutoCAD SHX Text 31.00
AutoCAD SHX Text 15.50
AutoCAD SHX Text
VENT & DRAIN
AutoCAD SHX Text
.50 NPT
AutoCAD SHX Text
TELL-TALE
AutoCAD SHX Text
.12 NPT
AutoCAD SHX Text
VENT & DRAIN
AutoCAD SHX Text
DETAIL "A"
AutoCAD SHX Text
FLUTTED OUTER TUBE TO
AutoCAD SHX Text
LEAK DETECTION CHAMBER
AutoCAD SHX Text
AND INNER TUBE TO TUBESHEET.
| Sheets and Views |
| Model |
| 2025-01-23T14:03:45-0600 | |
| SPINDLER.STEPHEN.WILLIAM.1276823422 |
File details come from the government source that posted it. Updated .