PW_25-13A_Napa_Library_Building_Maintenance_Project_Plans.pdf
PDF 14 MB Posted
- Attached to
- Napa Library Building Maintenance Project
- Solicitation number
- PW 25-13A
- Issued by
- Napa County, California
About this file
This document contains project plans for the Napa Library Building Maintenance Project in California, a public works initiative focused on exterior building maintenance and repairs. The project scope encompasses stucco patching, concrete spalling repairs, window and joint sealants, pressure washing, and repainting of various surfaces on the library facility. The plans provide detailed specifications and technical requirements for contractors bidding on the work, establishing the baseline standards and expectations for project execution. The document serves as the primary reference material for potential bidders to understand the full scope of work, site conditions, and performance standards required for this maintenance initiative.
The project plans establish the technical and operational framework necessary for contractors to develop accurate bids and project timelines. These specifications detail the materials, methods, quality standards, and site-specific conditions that bidders must address in their proposals. The plans function as binding reference documents that will govern the contractor's performance upon award, ensuring consistency with the original project design and the municipality's maintenance objectives for the library facility.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COVER SHEET
G000
N
AP
A
LI
BR
AR
Y
BU
IL
D
IN
G
M
AI
N
TE
N
AN
C E
N
AP
A C
O U
N
TY
ARCHITECT
REVISIONS
SHEET TITLE
SHEET NO.
JOB NO.: Y2505.00
DATE: 02/13/2026
NO. DESCRIPTION DATE
C oo m bs
S t, N ap a, C
A
CONSULTANT
O N
E-
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
IN
C H
T
W
EN
TY
F
EE
T
O
N E-
EI
G
H
TH
IN
C
H
O N
E
FO
O T
O
N E-
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T
O N
E
IN
C H
O
N E
FO
O
T
TH
R
EE
-Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
O N
E- H
AL
F
IN
C
H
O N
E
FO
O T
O
N E
AN
D
O N
E- H
AL
F
IN
C
H
O N
E
FO
O T
CONSTRUCTION DOCUMENTS
AGENCY APPROVAL
PW 25-13A
PROJECT LOCATION
NORTH
APPLICABLE CODES
EXTERIOR MAINTENANCE OF NAPA COUNTY LIBRARY :
· RESEAL GAP BETWEEN EXTERIOR WALLS AND FLATWORK
· REPAINT RAILINGS
· PATCH CONCRETE SOFFIT ABOVE WINDOW
· REPAINT STUCCO FINISH
· REMOVE AND REPLACE SEALANT AROUND DOOR AND WINDOW FRAMES
· REPAINT HOLLOW METAL DOORS AND FRAMES
GENERAL SCOPE OF WORK
PROJECT TEAM
NAPA COUNTY
NAPA LIBRARY
BUILDING MAINTENANCE
580 Coombs Street, Napa, CA 94559
1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE SITE AND SHALL REPORT ANY DISCREPANCIES IN WRITING TO THE CONSTRUCTION MANAGER BY THE MEANS
OF AN REQUEST FOR INFORMATION (RFI) OR AS PART OF THE APPLICABLE SHOP
DRAWING/SUBMITTAL.
2. SPECIFIC ITEMS NOTED TO BE VERIFIED OR FIELD VERIFIED ARE REQUIRED TO BE VERIFIED PRIOR
TO ORDERING MATERIALS OR PROCEEDING WITH THE WORK.
3. CONTRACTOR IS RESPONSIBLE FOR ALL INCIDENTAL WORK NECESSARY TO COMPLETE THE
INSTALLATION OF NEW WORK. THIS INCLUDES, BUT IS NOT LIMITED TO, THE REMOVAL AND/OR
REINSTALLATION OR ALL EXISTING ITEMS, OF PORTIONS OF THE EXISTING CONSTRUCTION
WHETHER SHOWN OR NOT.
4. ALL WORK, MATERIALS, METHODS, ETC. SHALL CONFORM TO ALL GOVERNING BUILDING CODES
AND REGULATIONS.
5. ANY CONFLICT BETWEEN THESE PLANS AND EXISTING CONDITIONS SHALL BE BROUGHT TO THE
IMMEDIATE ATTENTION OF THE ARCHITECT.
6. ALL WORK SHALL BE IN COMPLETE CONFORMANCE WITH MANUFACTURER'S SPECIFICATIONS AND
RECOMMENDATIONS OR AS OTHERWISE OUTLINED IN THE SPECIFICATIONS.
7. USE OF ANY NEW MATERIALS CONTAINING LEAD OR ASBESTOS IS PROHIBITED.
8. DETAILS, MATERIALS AND SCOPE OF WORK SHALL BE CONSIDERED TYPICAL FOR ALL SIMILAR
CONDITIONS UNLESS SPECIFICALLY NOTED OTHERWISE.
9. THE TERM "TYPICAL" OR "(TYP.)" SHALL BE CONSTRUED TO MEAN APPLYING TO ALL LIKE OR SIMILAR
CONDITIONS IN THE AREAS DESIGNATED FOR WORK SCOPE.
ALL WORK SHALL CONFORM TO THE FOLLOWING AND ALL OTHER APPLICABLE CODES AND ORDINANCES:
2025 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1, TITLE 24, C.C.R.
2025 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24, C.C.R.
OWNER:
NAPA COUNTY PUBLIC WORKS
1195 THIRD STREET, SUITE 101
NAPA, CA 94559
PHONE: (707) 259-8376
CONTACT: SU LIANG
liang.su@countyofnapa.org
ARCHITECT:
NACHT & LEWIS ARCHITECTS
600 Q STREET, SUITE 100
SACRAMENTO, CALIFORNIA 95811
PHONE: (916) 329-4000
CONTACT: LORENZO LOPEZ
llopez@nachtlewis.com
STRUCTURAL ENGINEER:
BUEHLER
600 Q STREET, SUITE 200
SACRAMENTO, CA 95811
PHONE: (916) 443-0303
CONTACT: BRIAN WIENS
bwiens@buehlerengineering.com
DEFERRED APPROVAL ITEMS
INSTALLATION OF DEFERRED APPROVAL ITEMS SHALL NOT BE STARTED UNTIL CONTRACTORS DRAWINGS, SPECIFICATIONS AND ENGINEERING CALCULATIONS FOR THE ACTUAL SYSTEMS TO BE INSTALLED HAVE BEEN ACCEPTED AND SIGNED BY THE
ARCHITECT OR ENGINEER, AND APPROVED BY THE APPROPRIATE APPROVING JURISDICTION.
1. NONE
https://www.openstreetmap.org/copyright
GENERAL NOTES
VICINITY MAP
SHEET INDEX
GENERAL
G000 COVER SHEET
ARCHITECTURAL
A100 SITE PLAN
A110 FIRST FLOOR PLAN
A300 EXTERIOR ELEVATIONS
STRUCTURAL
S101 GENERAL NOTES
S102 TYPICAL STRUCTURAL REPAIR NOTES AND DETAILS
SIGNAGE
1.01 COVER SHEET
1.02 TYPOGRAPHY, SYMBOLS, AND COLORS
1.03 LOCATION
1.04 ID.01 ENTRY MONUMENT ID
1.05 ID.02 BUILDING ID
1.06 ID.03 ENTRY MONUMENT ID / KIOSK
1.07 ID.04 PARKING ENTRY ID
1.08 DIR.01 VEHICULAR DIRECTIONAL
1.09 DIR.01 VEHICULAR DIRECTIONAL LAYOUT 2
1.10 DIR.02 PEDESTRIAN DIRECTIONAL
1.11 DIR.04 WALL MOUNTED PEDESTRIAN DIRECTIONAL
1.12 DIR.05 ISA DIRECTIONAL
1.13 INF.01 BOOK DROP INFORMATIONAL
1.14 INF.02 LIBRARY HOURS
1.15 INF.04 CURBSIDE PICKUP
1.16 REG.01 ACCESSIBLE PARKING
1.17 REG.02 ACCESSIBLE RAMP
1.18 REG.03 CVC
1.19 REG.04 DO NOT ENTER
1.20 LOC LOCATION MAP
PW 25-13A
09-30-26
06-24-26
BROWN STREET
FI
FT
H S
TR
EE
T
DI
VI
SI
O
N
ST
RE
ET
LIBRARY
Xref .\NL Keynotes.dwg
SCALE: 3/32" = 1'-0"
SITE PLAN
N O
R
TH
GENERAL NOTES: KEY PLAN:
BROWN STREETBROWN STREET
FI
FT
H S
TR
EE
T
DI
VI
SI
O
N
ST
RE
ETLIBRARY
PARKING
GARAGE
COOMBS STREET
MAIN STREET
NO
RT
H
SITE PLAN INCLUDED FOR REFERENCE SEE A110 AND A300
FOR WORK
BOOK RETURN
ADDITION
(STUCCO EXTERIOR)
ORIGINAL CONSTRUCTION
(CONCRETE EXTERIOR)
SMALL KIDS' LIBRARY
ADDITION
(STUCCO AND RAINSCREEN
EXTERIOR)
LOBBY
ADDITION
(STUCCO EXTERIOR)
Xref .\NL Keynotes.dwg
N
AP
A
LI
BR
AR
Y
BU
IL
D
IN
G
M
AI
N
TE
N
AN
C E
N
AP
A C
O U
N
TY
ARCHITECT
REVISIONS
SHEET TITLE
SHEET NO.
JOB NO.: Y2505.00
DATE: 02/13/2026
NO. DESCRIPTION DATE
C oo m bs
S t, N ap a, C
A
CONSULTANT
O N
E-
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
IN
C H
T
W
EN
TY
F
EE
T
O
N E-
EI
G
H
TH
IN
C
H
O N
E
FO
O T
O
N E-
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T
O N
E
IN
C H
O
N E
FO
O
T
TH
R
EE
-Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
O N
E- H
AL
F
IN
C
H
O N
E
FO
O T
O
N E
AN
D
O N
E- H
AL
F
IN
C
H
O N
E
FO
O T
CONSTRUCTION DOCUMENTS
AGENCY APPROVAL
LIBRARY
SITE PLAN
A100
PW 25-13A
Xref .\NL Keynotes.dwg
SCALE: 1/8" = 1'-0"
LIBRARY FIRST FLOOR PLAN
ADULT'S LIBRARY
BOOK DROP
FRIENDS OF LIBRARY
SAFE
ELEV.
MACH.
ROOM
STAIRS
EQUIP. TEEN
OFFICE
LIBRARY
CIRCULATION
TRASH
LITERARY
CENTER
CONF.
CHILDREN'S
LIBRARY OFFICE
GIRL'S
RR
BOY'S
RR
JANITOR
CHILDREN'S LIBRARY SMALL KIDS'
LIBRARY
BOOKDROP
WORKROOM
LOBBY
WOMEN
MEN
STORAGE
FOOD
SERVICE
LIFEWORKS
STORAGE
COMMUNITY
MEETING ROOM
STAIRS
LOBBY
BOOKDROP
ADDITION
GENERAL NOTES:KEYNOTES:
1. SEE A300 FOR WORK ON EXTERIOR ELEVATIONS.
2. CLEAN, PRIME AND PREPARE ALL SURFACES RECEIVING PAINT. REMOVE OR
PROTECT WALL MOUNTED EQUIPMENT IN PLACE PRIOR TO PAINTING.
3. INSTALL OR REPLACE WATER REPELLENTS ON EXPOSED CONCRETE WALLS
PER PLANS, ELEVATIONS AND SPECIFICATIONS.
1 RESEAL GAP BETWEEN EXTERIOR WALL AND FLATWORK AROUND
PERIMETER
RAILINGS- STRIP DOWN TO BARE METAL, PREP, PRIMER, AND PAINT. REFER TO
SPEC SECTION 09 91 13 FOR COMPLETE LIST OF REQUIREMENTS.
COLOR: DARK TEAL (RGB: 26,47,50)
3 REPAINT STUCCO FINISHES, COLOR: WHITE TO MATCH EXISTING STUCCO.
4 POWER WASH ALL EXTERIOR BUILDING SURFACE. PROTECT EXISTING
MURALS PRIOR TO COMMENCING WORK
5 REPAINT HOLLOW METAL DOORS AND FRAMES. COLOR TBD.
REMOVE AND REPLACE SEALANT AROUND HOLLOW METAL AND STOREFRONT
DOORS AND WINDOWS PER SPEC SECTION 07 90 00.
NOTE: ANY RENTAL COST AND MOBILIZATION DURING 15-DAY CURING PERIOD
SHALL BE AT NO COST TO THE COUNTY
PATCH CONCRETE SOFFITS OVER WINDOWS AND SLOPED SILLS WHERE OCCUR
SEE DETAIL 2/S102. USE CRACK LENGTH OF 36" AT EACH LOCATION FOR BASE
BID. EPOXY INJECTION REPAIR SHALL EXTEND THE FULL LENGTH OF THE
CRACK ALONG THE OVERHEAD AND VERTICAL FACES OF CONCRETE. SEE
SPECIFICATIONS FOR UNIT COST ADJUSTMENTS +/-
TYP.
7 77 7
TYP.
TYP.
NOT ALL KEYNOTES APPLY TO THIS SHEET
TYP.
TYP.
TYP.
1 1
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
9 PAINT CONCRETE SIDE WALLS IN WINDOW OPENINGS.
COLOR: TBD. REFER TO EXTERIOR ELEVATIONS ON 2/A300.
10 PATCH STUCCO SOFFIT AND/OR SLOPED SILLS WHERE OCCUR
COLOR: WHITE- MATCH EXISTING STUCCO.
9 99
TYP.
ADDITION (STUCCO EXTERIOR) ORIGINAL CONC. STRUCTURE
ORIGINAL
CONC. STRUCTURE
ADDITION
(STUCCO EXTERIOR)
ORIGINAL
CONC. STRUCTURE
ADDITION
(STUCCO EXTERIOR)
STUCCO EXTERIOR
CONCRETE STRUCTURE
GAP BETWEEN WALL AND FLATWORK TO
BE RESEALED
STUCCO SOFFIT AND SILL TO BE
PATCHED
CONCRETE SOFFIT TO BE PATCHED
ESTIMATED NUMBER OF CRACKS WITH
EFFLORESENCE STAINING AT WINDOW
SOFFIT THAT REQUIRE EPOXY
INJECTION FOR REPAIR. VERIFY IN
FIELD. SEE KEYNOTE 7 FOR PATCH.
LEGEND:
SOFFIT
ONLY
SOFFIT ONLY
SOFFIT
ONLY
BROWN STREET
DI
VI
SI
O
N
ST
RE
ET
CONCRETE SPALL OCCURS ON SPANDEL ABOVE WINDOW. REMOVE SPALL TO
EXTENTS AND REPAIR PER DETAIL 1/S102. PROVIDE GROUT REPAIR MOCKUP TO
MATCH COLOR AND TEXTURE PRIOR TO INSTALLATION.
11 ABOVE
WINDOW
1 3 3 6 2 2
ROOF ABOVE
TRELLIS ABOVE
12 PREP, PRIME, PAINT ALUMINUM WINDOW SYSTEM FRAMES.
COLOR: DARK TEAL (RGB: 26,47,50) TO MATCH RAILINGS.
SOFFIT
ONLY
6 6
REPLACE SCUPPER AND ADD NEW DOWN SPOUT.
COLOR: TBD.
N
AP
A
LI
BR
AR
Y
BU
IL
D
IN
G
M
AI
N
TE
N
AN
C E
N
AP
A C
O U
N
TY
ARCHITECT
REVISIONS
SHEET TITLE
SHEET NO.
JOB NO.: Y2505.00
DATE: 02/13/2026
NO. DESCRIPTION DATE
C oo m bs
S t, N ap a, C
A
CONSULTANT
O N
E-
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
IN
C H
T
W
EN
TY
F
EE
T
O
N E-
EI
G
H
TH
IN
C
H
O N
E
FO
O T
O
N E-
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T
O N
E
IN
C H
O
N E
FO
O
T
TH
R
EE
-Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
O N
E- H
AL
F
IN
C
H
O N
E
FO
O T
O
N E
AN
D
O N
E- H
AL
F
IN
C
H
O N
E
FO
O T
CONSTRUCTION DOCUMENTS
AGENCY APPROVAL
PW 25-13A
LIBRARY
FIRST FLOOR PLAN
A110
N O
R
TH
Xref .\NL Keynotes.dwg
SCALE: 1/8" = 1'-0"
LIBRARY EXTERIOR ELEVATION - WEST
SCALE: 1/8" = 1'-0"
LIBRARY EXTERIOR ELEVATION - EAST
SCALE: 1/8" = 1'-0"
LIBRARY EXTERIOR ELEVATION - NORTH
SCALE: 1/8" = 1'-0"
LIBRARY EXTERIOR ELEVATION - SOUTH
GENERAL NOTES:KEYNOTES:
1 RESEAL GAP BETWEEN EXTERIOR WALL AND FLATWORK AROUND PERIMETER
2 REPAINT RAILING. SEE SPEC SECTION 09 91 13
COLOR: DARK TEAL (RGB: 26, 47, 50)
3 REPAINT STUCCO FINISHES, COLOR: WHITE TO MATCH EXISTING STUCCO.
5 REPAINT HOLLOW METAL DOORS AND FRAMES. COLOR TBD.
7 PATCH CONCRETE SOFFITS OVER WINDOWS.SEE DETAIL 2/S102. USE CRACK
LENGTH OF 36" AT EACH LOCATION FOR BASE BID. EPOXY INJECTION REPAIR
SHALL EXTEND THE FULL LENGTH OF THE CRACK ALONG THE OVERHEAD
AND VERTICAL FACES OF CONCRETE. SEE SPECIFICATIONS FOR UNIT COST
ADJUSTMENTS +/-. AFTER PATCH, PAINT JAMBS AND SOFFIT OF OPENINGS
INCLUDING BEVEL. COLOR TBD.
8 REPLACE SCUPPER AND ADD NEW DOWN SPOUT.
COLOR: TBD.
PAINTED CONCRETE.
COLOR: TBD.
LEGEND:
SEALANT BETWEEN BUILDING EDGE AND FLATWORK TO BE
REMOVED AND REPLACED
SEALANT AROUND DOOR AND WINDOW FRAMES TO BE REMOVED
AND REPLACED.
6 6
4 64 6 4 6 4 6 66 6 44
3 3
7 7
7 7 7 7
NOT ALL KEYNOTES APPLY TO THIS SHEET 1. CONTRACTOR SHALL VERIFY EXISTING BUILDING CONDITIONS PRIOR TO PAINTING
AND RESEALING.
2. CLEAN AND PREP PERIMETER AROUND OPENINGS THAT RECEIVE NEW SEALANT.
MASK ALL JOINTS WITH MASKING TAPE, AND REMOVE IMMEDIATELY AFTER
TOOLING SEALANT.
3. THOROUGHLY POWER WASH AND CLEAN ALL SURFACES RECEIVING NEW PAINT.
PRIME AND PREPARE ALL SURFACES, FILL CRACKS, VOIDS AND HOLES WITH
MATERIAL SUITABLE TO SUBSTRATE. SCRAPE AND SAND LOOSE ANY PEELING
PAINT. SEE SPECIFICATIONS FOR ADDITIONAL SURFACE PREP INSTRUCTIONS AND
INFORMATION. CONTRACTOR IS RESPONSIBLE FOR CLEANING ALL PAINT
OVER-SPRAY.
4. CLEANLY AND CAREFULLY MASK ALL DOOR HARDWARE NOT BEING REMOVED.
ANY NEW PAINT FOUND ON DOOR HARDWARE WILL REQUIRE THE CONTRACTOR
TO REMOVE THE HARDWARE COMPONENTS, CLEAN AND REINSTALL AT NO
ADDITIONAL COST TO THE OWNER. DO NOT PAINT CLEAR ANODIZED ALUMINUM
CONTINUOUS HINGES AT DOORS.
REPAINTED STUCCO.
COLOR: WHITE- MATCH EXISTING STUCCO.
3 33
9 PAINT FALSE SILL TO ALIGN WITH BOTTOM OF STUCCO AT THE SMALL KIDS' LIBRARY.
COLOR: TBD.
9 9 9 9 49
RAINSCREEN EXTERIOR
RAINSCREEN
EXTERIOR
RAINSCREEN
EXTERIOR
(E) RAINSCREEN EXTERIOR (NOT IN SCOPE)
(E) STANDING SEAM ROOF (NOT IN SCOPE)
10 (NOTE NOT USED)
CONCRETE SPALL OCCURS ON SPANDEL ABOVE WINDOW. REMOVE SPALL TO
EXTENTS AND REPAIR PER DETAIL 1/S102. PROVIDE GROUT REPAIR MOCKUP TO
MATCH COLOR AND TEXTURE PRIOR TO INSTALLATION.
7 7 11
12 PREP, PRIME, PAINT ALUMINUM WINDOW SYSTEM FRAMES.
COLOR: DARK TEAL (RGB: 26, 47, 50) TO MATCH RAILINGS
12 12
POWER WASH ALL EXTERIOR BUILDING SURFACE. PROTECT EXISTING
MURALS PRIOR TO COMMENCING WORK
REMOVE AND REPLACE SEALANT AROUND HOLLOW METAL AND STOREFRONT
DOORS AND WINDOWS PER SPEC SECTION 07 90 00.
NOTE: ANY RENTAL COST AND MOBILIZATION DURING 15-DAY CURING PERIOD
SHALL BE AT NO COST TO THE COUNTY
TYP.9 9 9
N
AP
A
LI
BR
AR
Y
BU
IL
D
IN
G
M
AI
N
TE
N
AN
C E
N
AP
A C
O U
N
TY
ARCHITECT
REVISIONS
SHEET TITLE
SHEET NO.
JOB NO.: Y2505.00
DATE: 02/13/2026
NO. DESCRIPTION DATE
C oo m bs
S t, N ap a, C
A
CONSULTANT
O N
E-
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
IN
C H
T
W
EN
TY
F
EE
T
O
N E-
EI
G
H
TH
IN
C
H
O N
E
FO
O T
O
N E-
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T
O N
E
IN
C H
O
N E
FO
O
T
TH
R
EE
-Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
O N
E- H
AL
F
IN
C
H
O N
E
FO
O T
O
N E
AN
D
O N
E- H
AL
F
IN
C
H
O N
E
FO
O T
CONSTRUCTION DOCUMENTS
AGENCY APPROVAL
PW 25-13A
LIBRARY
EXTERIOR ELEVATIONS
A300
GENERAL NOTES
100SN001
1. INTERPRETATION OF DRAWINGS & SPECIFICATIONS
A. WHERE SPECIFICATIONS HAVE BEEN PREPARED FOR THIS PROJECT, THEY ARE ARRANGED
IN SEVERAL SECTIONS, BUT SUCH SEPARATION SHALL NOT BE CONSIDERED AS THE LIMITS
OF THE WORK REQUIRED OF ANY SEPARATE TRADE. THE TERMS AND CONDITIONS OF
SUCH LIMITATIONS ARE WHOLLY BETWEEN THE CONTRACTOR AND THEIR
SUBCONTRACTORS.
B. IN GENERAL, THE WORKING DETAILS WILL INDICATE DIMENSIONS, POSITION AND KIND OF
CONSTRUCTION, AND THE SPECIFICATIONS, QUALITIES AND METHODS. ANY WORK
INDICATED ON THE WORKING DETAILS AND NOT MENTIONED IN THE SPECIFICATIONS, OR
VICE VERSA, SHALL BE FURNISHED AS THOUGH FULLY SET FORTH IN BOTH. WORK NOT
PARTICULARLY DETAILED, MARKED OR SPECIFIED, SHALL BE IDENTICAL OR SIMILAR TO LIKE
CASES OF CONSTRUCTION THAT ARE DETAILED, MARKED OR SPECIFIED. IF CONFLICTS
OCCUR ON DRAWINGS AND/OR SPECIFICATIONS, THE MOST EXPENSIVE MATERIALS OR
METHODS WILL PREVAIL.
C. SHOULD AN ERROR APPEAR IN THE WORKING DETAILS OR SPECIFICATIONS OR IN WORK
DONE BY OTHERS AFFECTING THIS WORK, THE CONTRACTOR SHALL NOTIFY THE
ARCHITECT AT ONCE AND IN WRITING. IF THE CONTRACTOR PROCEEDS WITH THE WORK
SO AFFECTED WITHOUT HAVING GIVEN SUCH WRITTEN NOTICE AND WITHOUT RECEIVING
THE NECESSARY APPROVAL, DECISION OR INSTRUCTIONS IN WRITING FROM THE OWNER,
THEN THE CONTRACTOR SHALL HAVE NO VALID CLAIM AGAINST THE OWNER, FOR THE
COST OF SO PROCEEDING AND SHALL MAKE GOOD ANY RESULTING DAMAGE OR DEFECT.
NO VERBAL APPROVAL, DECISION, OR INSTRUCTION SHALL BE VALID OR BE THE BASIS FOR
ANY CLAIM AGAINST THE OWNER, ITS OFFICERS, EMPLOYEES OR AGENTS. THE
FOREGOING INCLUDES TYPICAL ERRORS IN THE SPECIFICATIONS OR NOTATIONAL ERRORS
IN THE WORKING DETAILS WHERE THE INTERPRETATION IS DOUBTFUL OR WHERE THE
ERROR IS SUFFICIENTLY APPARENT AS TO PLACE A REASONABLY PRUDENT CONTRACTOR
ON NOTICE THAT, SHOULD THE CONTRACTOR ELECT TO PROCEED, THEY ARE DOING SO AT
THEIR OWN RISK.
2. CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS.
3. SHOP DRAWING NOTE:
A. WHEN NOT ADDRESSED BY DIVISION 1 OF THE SPECIFICATIONS, SUBMITTALS SHALL BE
ELECTRONIC PDF FORMAT.
B. THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE
TO THE STRUCTURAL ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN
CONCEPT BY INDICATING WHICH MATERIAL THE CONTRACTOR INTENDS TO FURNISH AND
INSTALL, AND BY DETAILING THE FABRICATION AND INSTALLATION METHODS THE
CONTRACTOR INTENDS TO USE ON A STAND ALONE SET OF DOCUMENTS. DUPLICATION OF
DESIGN DOCUMENTS FOR THE PURPOSE OF SHOP DRAWINGS IS NOT ACCEPTABLE.
C. PRIOR TO FABRICATION, SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW BY THE
STRUCTURAL ENGINEER. SHOP DRAWING SUBMITTALS SHALL INCLUDE, BUT ARE NOT
NECESSARILY LIMITED TO, STRUCTURAL STEEL, REINFORCING STEEL, & GLUE-LAMINATED
BEAMS.
D. PRIOR TO SUBMISSION THE CONTRACTOR SHALL REVIEW ALL SUBMITTALS FOR
CONFORMANCE WITH THE CONTRACT DOCUMENTS AND SHALL STAMP SUBMITTALS AS
BEING "REVIEWED FOR CONFORMANCE".
E. SHOP DRAWING SUBMITTALS PROCESSED BY THE STRUCTURAL ENGINEER ARE NOT
CHANGE ORDERS.
F. ANY DETAIL ON THE SHOP DRAWINGS THAT DEVIATES FROM THE CONTRACT DOCUMENTS
SHALL CLEARLY BE MARKED WITH THE NOTE "THIS IS A CHANGE".
G. SHOP DRAWINGS OR CALCULATIONS SUBMITTED FOR REVIEW THAT REQUIRE
RESUBMITTAL FOR RE-REVIEW SHALL BE BILLED HOURLY FOR SUCH TIME TO THE GENERAL
CONTRACTOR. RE-REVIEW WILL NOT PROCEED WITHOUT WRITTEN APPROVAL FROM THE
GENERAL CONTRACTOR FOR ADDITIONAL ENGINEERING REVIEW SERVICES.
4. SAFETY NOTE:
A. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH THE PERTINENT SECTIONS, AS
THEY APPLY TO THIS PROJECT, OF THE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE
STATE OF CALIFORNIA LATEST EDITION, AND ALL OSHA REQUIREMENTS.
B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE DESIGN AND CONSTRUCTION
OF ALL FORMS AND SHORING REQUIRED. SHORING INDICATIONS (LOCATION, DIRECTION,
DURATION, ETC.) ARE ONLY SHOWN ON THE STRUCTURAL DRAWINGS WHEN REQUIRED TO
IMPLEMENT THE DESIGN INTENT OF THE FINAL WORK PRODUCT. DETERMINATION
WHETHER SHORING IS REQUIRED FOR TEMPORARY OR INTERMEDIATE CONDITIONS
DURING CONSTRUCTION IS WHOLLY THE RESPONSIBILITY OF THE CONTRACTOR.
C. THE OWNER AND THE STRUCTURAL ENGINEER DO NOT ACCEPT ANY RESPONSIBILITY FOR
THE CONTRACTOR'S FAILURE TO COMPLY WITH THESE REQUIREMENTS.
5. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND STRUCTURAL ENGINEER WHERE A
CONFLICT OR DISCREPANCY OCCURS BETWEEN THE STRUCTURAL DRAWINGS AND ANY
OTHER PORTION OF THE CONTRACT DOCUMENTS OR EXISTING FIELD CONDITIONS. SUCH
NOTIFICATION SHALL BE GIVEN IN DUE TIME SO AS NOT TO AFFECT THE CONSTRUCTION
SCHEDULE. IN CASE OF A CONFLICT BETWEEN STRUCTURAL DRAWINGS AND SPECIFICATIONS
THE MORE RESTRICTIVE CONDITION SHALL TAKE PRECEDENCE UNLESS WRITTEN APPROVAL
HAS BEEN GIVEN FOR THE LEAST RESTRICTIVE. CONTRACTOR SHALL VERIFY ALL DIMENSIONS
WITH ARCHITECTURAL PRIOR TO COMMENCING ANY WORK.
6. WHEN CONSTRUCTION ATTACHES TO OR IS WITHIN AN EXISTING BUILDING, A COMPLETE SET OF DRAWINGS OF THE EXISTING BUILDING SHALL BE KEPT ON THE JOB SITE. CONTRACTOR TO
OBTAIN THESE DRAWINGS FROM THE OWNER (IF THEY ARE AVAILABLE).
7. CONTRACTOR SHALL PROVIDE AN ALLOWANCE EQUAL TO 2% OF THE BID FOR STRUCTURAL
STEEL, MISC. IRON AND REINFORCING STEEL TO BE USED AT THE DISCRETION OF THE
STRUCTURAL ENGINEER. UNUSED AMOUNT TO REVERT TO THE OWNER UPON COMPLETION
OF THE JOB.
8. ANY SUBSTITUTIONS FOR STRUCTURAL MEMBERS, HARDWARE OR DETAILS SHALL BE
REVIEWED BY THE ARCHITECT AND STRUCTURAL ENGINEER. SUCH REVIEW WILL BE BILLED
ON A TIME AND MATERIALS BASIS TO THE GENERAL CONTRACTOR WITH NO GUARANTEE THAT
THE SUBSTITUTION WILL BE ALLOWED.
9. DO NOT SCALE DRAWINGS. CONTACT THE ARCHITECT OR STRUCTURAL ENGINEER FOR ANY
DIMENSIONS NOT SHOWN.
10. THESE DRAWINGS ARE NOT COMPLETE UNTIL REVIEWED AND ACCEPTED BY LOCAL BUILDING
OFFICIALS AND THE OWNER AND SIGNED BY THE STRUCTURAL ENGINEER.
DESIGN CRITERIA
100SN002
1. CODES AND STANDARDS
2025 CALIFORNIA BUILDING CODE (CBC)
ASCE 7-22
ACI 318-19
AISC 360-22, 341-22, 358-22
AISI S100-16 w/ S2-20, S240-20, S400-20
TMS 402/602-2022
2024 NDS, 2021 SDPWS
(A) -
AB -
ABV -
ADDL -
AHU -
ALT -
APPROX -
AR -
ARCH -
(B) -
BLDG -
BLKG -
BLW -
BM -
B.O. -
BOF -
BOTT -
BRCG -
BRG -
BTWN -
BYND -
CC -
CG -
CJ -
CJP -
CL -
CLG -
CLR -
CMU -
COL -
CONC -
CONN -
CONT -
CONTR -
COORD -
CSK -
DBL -
DF -
DIAG -
DL -
DWG -
(E) -
EA -
EF -
EFF -
EJ -
ELEC -
ELEV -
EN -
EOS -
EQ -
ES -
EW -
EXT -
FB -
FC -
FDN -
FF -
FRMG -
FRT -
FS -
FTG -
GA -
GALV -
GLB -
GR -
GYP -
HD -
HDG -
HDR -
HGR -
HK -
HORIZ -
HSB -
HSS -
HT -
INT -
OCCURS ABOVE
ANCHOR BOLT
ABOVE
ADDITIONAL
AIR HANDLING UNIT
ALTERNATE
APPROXIMATE
ANCHOR ROD
ARCHITECTURAL
OCCURS BELOW
BUILDING
BLOCKING
BELOW
BEAM
BOTTOM OF
BOTTOM OF FOOTING
BOTTOM
BRACING
BEARING
BETWEEN
BEYOND
CENTER TO CENTER
CENTER OF GRAVITY
CONSTRUCTION JOINT
COMPLETE JOINT PENETRATION
CENTERLINE
CEILING
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONNECTION
CONTINUOUS
CONTRACTOR
COORDINATE
COUNTERSINK
DOUBLE
DOUGLAS FIR
DIAGONAL
DEAD LOAD
DRAWING
EXISTING
EACH
EACH FACE OR EDGE FASTENER
EFFECTIVE
EXPANSION JOINT
ELECTRICAL
ELEVATION
EDGE NAILING
EDGE OF SLAB
EQUAL
EACH SIDE
EACH WAY
EXTERIOR
FACE OF BLOCK/BRICK OR FLAT BAR
FACE OF CONCRETE
FOUNDATION
FINISH FLOOR
FRAMING
FIRE RETARDANT TREATED
FACE OF STUD OR FAR SIDE
FOOTING
GAUGE OR GAGE
GALVANIZED
GLUED LAMINATED BEAM
GRADE
GYPSUM
HOLDOWN
HOT-DIPPED GALVANIZED
HEADER
HANGER
HOOK
HORIZONTAL
HIGH STRENGTH BOLT
HOLLOW STRUCTURAL SECTION
HEIGHT
INTERIOR
JH -
LL -
LLH -
LLV -
LONGIT -
LS -
LW -
LWC -
MECH -
MFR -
MI -
MTL -
(N) -
NIC -
NS -
NTS -
NW -
NWC -
o/ -
OD -
OH -
OPNG -
OSB -
PAF -
PC -
PERP -
PJ -
PJP -
PL -
PT -
PW -
REINF -
REQD -
RWD -
SC -
SCH -
SEOR -
SHTG -
SIM -
SJ -
SMS -
SOG -
SP -
SPCG -
SQ -
SS -
STD -
STFNR -
STGRD -
STL -
STRUCT -
SW -
T&B - T&G -
THRD -
TN -
T.O. -
TOC -
TOF -
TOS -
TOW -
TRANS -
TYP -
UNO -
VERT -
VIF -
WF -
WHS -
WP -
WS -
WWF -
XS -
XXS -
Ø -
JOIST HANGER
LIVE LOAD
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LONGITUDINAL
LAG SCREW
LIGHTWEIGHT
LIGHTWEIGHT CONCRETE
MECHANICAL
MANUFACTURER
MALLEABLE IRON
MARK
METAL
NEW
NOT IN CONTRACT
NEAR SIDE
NOT TO SCALE
NORMAL WEIGHT
NORMAL WEIGHT CONCRETE
OVER
OUTSIDE DIAMETER
OPPOSITE HAND
OPENING
ORIENTED STRAND BOARD
POWER ACTUATED FASTENER
PIECE
PERPENDICULAR
PANEL JOINT
PARTIAL JOINT PENETRATION
PLATE
PRESSURE TREATED OR POST-TENSIONED
PUDDLE WELD
REINFORCING OR REINFORCEMENT
REQUIRED
REDWOOD
SLIP CRITICAL
SCHEDULE
STRUCTURAL ENGINEER OF RECORD
SHEATHING
SIMILAR
SLAB CONTROL JOINT
SHEET METAL SCREW
SLAB-ON-GRADE
STRUCTURAL PANEL
SPACING
SQUARE
STAINLESS STEEL
STANDARD
STIFFENER
STAGGERED
STEEL
STRUCTURAL
SHEAR WALL
TOP & BOTTOM
TONGUE & GROOVE
THREADED
TOE NAIL
TOP OF
TOP OF CONCRETE (SLAB UNO)
TOP OF FOOTING OR TOP OF FRAMING
TOP OF STEEL
TOP OF WALL
TRANSVERSE
TYPICAL
UNLESS NOTED OTHERWISE
VERTICAL
VERIFY IN FIELD
WIDE FLANGE
WELDED HEADED STUD
WORK POINT
WOOD SCREW
WELDED WIRE FABRIC
EXTRA STRONG
DOUBLE EXTRA STRONG
ROUND OR DIAMETER
ABBREVIATIONS
100SN003
STATEMENT OF STRUCTURAL SPECIAL INSPECTIONS AND TESTING
110SN001
1. SPECIAL INSPECTIONS AND TESTING SHALL BE PROVIDED BY A TESTING AND INSPECTION
AGENCY, EMPLOYED BY THE OWNER (OR OWNER'S AUTHORIZED AGENT), AND APPROVED BY
THE BUILDING OFFICIAL TO PROVIDE SPECIAL INSPECTIONS AND TESTING FOR THE
PARTICULAR TYPE OF CONSTRUCTION.
2. TABLES OF SPECIAL INSPECTIONS AND TESTING ARE DERIVED FROM THE STRUCTURAL
PROVISIONS OF THE CBC AND REFERENCED STANDARDS AND ARE FOR REFERENCE ONLY.
THE INCLUDED TABLES ARE PROVIDED FOR THE CONVENIENCE OF THE OWNER, TESTING
AGENCY AND CONTRACTOR IN DEVELOPING THE SCOPE OF WORK FOR REQUIRED TESTING
AND INSPECTION OF STRUCTURAL MATERIALS AND COMPONENTS. REFER TO THE
SPECIFICATIONS FOR ADDITIONAL SPECIAL INSPECTION AND TESTING REQUIREMENTS. FINAL
DEFINITION OF THIS SCOPE OF WORK IS TO BE DETERMINED BY THE TESTING AGENCY AND
THE OWNER (OR OWNER'S AUTHORIZED AGENT).
3. FREQUENCY OF SPECIAL INSPECTIONS AND TESTING SHALL BE, AT A MINIMUM, AS NOTED FOR
THE INDIVIDUAL ELEMENTS WITHIN THE TABLES BELOW. THE CONTRACTOR SHALL
COORDINATE TIMING OF SPECIAL INSPECTIONS AND TESTING WITH THE SPECIAL INSPECTION
AND TESTING AGENCY.
4. PRIOR TO THE START OF CONSTRUCTION, THE TESTING AND INSPECTION AGENCY SHALL
PROVIDE DOCUMENTATION TO THE BUILDING OFFICIAL DEMONSTRATING COMPETENCE AND
RELEVANT EXPERIENCE OR TRAINING OF THE SPECIAL INSPECTORS WHO WILL PERFORM THE
SPECIAL INSPECTIONS AND TESTS DURING CONSTRUCTION, IN ACCORDANCE WITH CBC
SECTION 1704.2.1.
5. THE TESTING AND INSPECTION AGENCY SHALL SUBMIT REPORTS OF SPECIAL INSPECTIONS
AND TESTS TO THE BUILDING OFFICIAL, STRUCTURAL ENGINEER OF RECORD AND THE
CONTRACTOR, PER CBC SECTION 1704.2.4. THE REPORTS SHALL INDICATE THE NATURE AND
EXTENT OF INSPECTIONS AND TESTS, THE LOCATION WHERE THE INSPECTIONS AND TESTS
WERE PERFORMED, AND WHETHER WORK INSPECTED OR TESTED CONFORMED TO THE
APPROVED CONSTRUCTION DOCUMENTS. ANY DISCREPANCIES SHALL BE IMMEDIATELY
BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR CORRECTION. IF DISCREPANCIES
ARE NOT CORRECTED, THEY SHALL BE BROUGHT TO THE ATTENTION OF THE BUILDING
OFFICIAL AND THE STRUCTURAL ENGINEER OF RECORD.
6. SPECIAL INSPECTION AND TESTING RECORDS SHALL BE RETAINED BY THE CONTRACTOR ON
SITE UNTIL COMPLETION OF CONSTRUCTION.
7. THE CONTRACTOR SHALL SUBMIT A WRITTEN STATEMENT TO THE BUILDING OFFICIAL
ACKNOWLEDGING RESPONSIBILITY FOR CONSTRUCTION OF THE MAIN LATERAL-FORCE
RESISTING SYSTEM PRIOR TO COMMENCEMENT OF THAT WORK AS REQUIRED BY CBC
SECTION 1704.4.
8. THE OWNER OR THE OWNER'S AUTHORIZED AGENT SHALL SUBMIT TO THE BUILDING OFFICIAL, A FINAL REPORT DOCUMENTING SPECIAL INSPECTIONS AND TESTS PER CBC SECTION 1704.2.4, AND REPORTS AND CERTIFICATES PER CBC SECTION 1704.5.
9. SPECIAL INSPECTIONS AND TESTING SHALL BE PERFORMED DURING CONSTRUCTION ON THE
WORK SHOWN IN THE CONSTRUCTION DOCUMENTS AS REQUIRED BY CBC CHAPTER 17, THE
TABLES LISTED BELOW, AND THE JURISDICTION'S SPECIAL INSPECTION AND TESTING FORM.
IF DISCREPANCIES ARE NOTED, CONTACT THE SEOR. ALL EXCEPTIONS INCLUDED IN CBC
CHAPTER 17 ARE PERMITTED TO BE USED, WHERE APPLICABLE.
• CONCRETE REPAIRS
3. VERIFY USE OF REQUIRED DESIGN
CONCRETE REPAIR MORTAR.
ACI 318: CH. 19, 26.4.3,
26.4.4
- X
4. INSPECT CONCRETE REPAIR AREA
FOR PROPER APPLICATION
TECHNIQUES.
ACI 318: 26.5
5. VERIFY MAINTENANCE OF SPECIFIED
CURING TEMPERATURE AND
TECHNIQUES.
ACI 318: 26.5.3-26.5.5- X
6. INSPECT REPAIR AREA PREPARATION
FOR SHAPE, LOCATION AND
DIMENSIONS OF THE CONCRETE
MEMBER BEING REPAIRED.
ACI 318: 26.11.1.2(b)- X
X -
TYPE
CONCRETE CONSTRUCTION - REQUIRED SPECIAL INSPECTIONS AND TESTS
CBC TABLE 1705.3
110SN301
CONTINUOUS REFERENCED STANDARD aPERIODIC
1. INSPECT REINFORCEMENT FOR
DAMAGE PRIOR TO REPAIR
PATCHING.
ACI 318 CH. 20, 25.2, 25.3,
26.6.1-26.6.3
- X
2. REINFORCING BAR WELDING:
S
S
T A T E O F C A L I F O R N I A
STRUCTURAL
R
EFORP
DE
R E
T
SI
G E
S I N
EN
G
I N E
E R
O
AL
600 Q Street, Suite 100 Sacramento, CA 95811 www.nachtlewis.com 916.329.4000
600 Q STREET, SUITE 200
SACRAMENTO, CA 95811
916 443 0303
B u e h le r P ro je c t
-0 e v it
N
AP
A C
O U
N
TY
N
AP
A
LI
BR
AR
Y
BU
IL
D
IN
G
M
AI
N
TE
N
AN
C E
O N
E-
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
IN
C H
T
W
EN
TY
F
EE
T
O
N E-
EI
G
H
TH
IN
C
H
O N
E
FO
O T
O
N E-
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T
O N
E
IN
C H
O
N E
FO
O
T
TH
R
EE
-Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
O N
E- H
AL
F
IN
C
H
O N
E
FO
O T
O
N E
AN
D
O N
E- H
AL
F
IN
C
H
O N
E
FO
O T
ARCHITECT
REVISIONS
SHEET TITLE
SHEET NO.
JOB NO.: Y2505.00
DATE: 02/13/2026
NO. DESCRIPTION DATE
C oo m bs
S t, N ap a, C
A
CONSULTANT
CONSTRUCTION DOCUMENTS
AGENCY APPROVAL
BRIAN S.
WIENS
No. 6259
GENERAL NOTES
S101
APPLICABLE TO ALL DRAWINGS UNLESS NOTED OR SHOWN OTHERWISE
GENERAL NOTES
APPLICABLE TO ALL DRAWINGS UNLESS NOTED OR SHOWN OTHERWISE
STRUCTURAL SPECIAL INSPECTIONS AND TESTING
MATERIALS:
1. PARTICULAR PRODUCTS MAY BE SPECIFIED FOR REPAIRS, FOR COATING SURFACES, OR FOR
OTHER USES. THE CONTRACTOR SHALL USE THE SPECIFIED PRODUCTS, OR REQUEST THE USE OF AN ALTERNATIVE PRODUCT BY SUBMITTING FULL AND DETAILED EVIDENCE THAT THE ALTERNATIVE PRODUCT IS EQUIVALENT IN EVERY WAY. IT IS SOLELY INCUMBENT UPON THE CONTRACTOR TO
DEMONSTRATE PRODUCT EQUIVALENCY WHERE ALTERNATIVE PRODUCTS ARE REQUESTED. NO
SCHEDULE DELAYS OR COST CHANGES WILL BE ACCEPTED IN CONJUNCTION WITH CONTRACTOR
REQUESTS FOR THE USE OF ALTERNATIVE PRODUCTS. ALL CHANGES TO BE SUBMITTED TO THE
ENGINEER-OF-RECORD FOR REVIEW.
A. CONCRETE: SIKATOP-123 PLUS
B. REINFORCEMENT CORROSION PROTECTION: SIKA ARMATEC -110 EPOCEM
NOTES:
1. THESE NOTES HIGHLIGHT CONTRACTOR REQUIREMENTS IN MANY IMPORTANT AREAS OF THE
WORK. THEY ARE NOT STAND-ALONE REQUIREMENTS. THIS WORK MUST BE COORDINATED WITH
THE CONTRACT DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THIS WORK
WITH THE CONTRACT DRAWINGS TO ASSURE THAT ALL PROJECT REQUIREMENTS ARE FULFILLED.
2. CONTRACTOR QUALIFICATIONS: CONTRACTOR SHALL BE QUALIFIED IN THE FIELD OF CONCRETE
REPAIR AND PROTECTION WITH A SUCCESSFUL TRACK RECORD OF 5 YEARS OR MORE.
CONTRACTOR SHALL MAINTAIN QUALIFIED PERSONNEL WHO HAVE RECEIVED PRODUCT TRAINING
BY A MANUFACTURER'S REPRESENTATIVE.
3. REFER TO ACI RAP-6 "VERTICAL AND OVERHEAD SPALL REPAIR BY HAND APPLICATION" FOR
BACKGROUND AND DETAILED DESCRIPTION OF THIS METHOD.
4. INSTALL MATERIALS IN ACCORDANCE WITH ALL SAFETY, WEATHER CONDITIONS, MATERIAL
HANDLING AND INSTALLATION PROCEDURES REQUIRED BY THE MANUFACTURER, OR AS MODIFIED BY APPLICABLE RULES AND REGULATIONS OF LOCAL, STATE, AND FEDERAL AUTHORITIES HAVING
JURISDICTION. CONSULT MATERIAL SAFETY DATA SHEETS FOR COMPLETE HANDLING
RECOMMENDATIONS
5. IN ALL CASES, THE EXACT RECOMMENDATIONS OF THE PRODUCT MANUFACTURER FOR
PREPARATORY WORK AND ACTUAL PLACEMENT OF REPAIR MATERIALS SHALL BE STRICTLY
ADHERED TO. IN THE EVENT OF A CONFLICT BETWEEN A MANUFACTURER'S RECOMMENDATION
AND THESE DRAWINGS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER
FOR RESOLUTION.
6. TOOLS AND EQUIPMENT:
A. ALL CONCRETE REMOVAL SHALL BE DONE WITH SMALL, HAND-HELD PNEUMATIC CHIPPING
TOOLS. USE OF LARGER TOOLS MAY DAMAGE SUBSTRATE OR REINFORCEMENT. REMOVAL
SHALL BE PERFORMED USING A 15-POUND JACKHAMMER UNLESS ALTERNATE METHODS ARE
SUBMITTED FOR REVIEW BY THE ENGINEER. CARE SHALL BE TAKEN TO PREVENT ANY OIL,
LUBRICANTS OR OTHER MATERIALS DETRIMENTAL TO BONDING OF PATCHING MATERIALS TO
CONCRETE FROM CONTACTING THE SURFACE OF THE AREA BEING CHIPPED.
B. POWER WIRE BRUSH CLEANING DENOTES THE USE OF A HAND-HELD TOOL WITH A ROTARY
WIRE BRUSH. THE BRUSH SHALL HAVE SHORT, STIFF WIRE BRISTLES IN ORDER TO ASSURE
THAT FULL MANUAL PRESSURE CAN BE APPLIED FOR EFFECTIVE REMOVAL OF RUST AND
CORROSION.
C. NEEDLE SCALING DENOTES CLEANING USING PNEUMATIC TOOLS UTILIZING A GROUP OF SMALL
DIAMETER STEEL RODS POWERED BY AN INTERNAL PISTON.
D. HIGH PRESSURE WATER CLEANING DENOTES CLEANING USING WATER SPRAYED THROUGH A
NOZZLE AT HIGH PRESSURE (3,000 TO 10,000 PSI). WHEN SAND IS MIXED WITH THE WATER
SPRAY FASTER CLEANING AND ROUGHER SURFACES ARE PRODUCED.
E. ABRASIVE BLAST DENOTES CLEANING USING ABRASIVES MIXED WITH PRESURIZED AIR AND
PROJECTED THROUGH A NOZZLE. WHERE WATER IS INJECTED AT THE NOZZLE, DUST CAN BE
REDUCED.
7. EXECUTION:
A. PRIOR TO REPAIR, IDENTIFY AND MARK THE PERIMETER OF PLANNED REPAIR AREAS. IF
REINFORCING CORROSION IS IDENTIFIED IN THE REPAIR AREA, USE CHIPPING HAMMER TO
EXPOSE THE REINFORCEMENT UNTIL UNCORRODED BAR IS FOUND. REPAIR AREA SHALL
ENCOMPASS THE BOUNDARY OF CORROSION THAT HAS BEEN DISCOVERED. PERIMETER OF
REPAIR AREAS SHALL BE A SIMPLE RECTANGULAR SHAPE WITH AS FEW RE-ENTRANT CORNERS
AS POSSIBLE. JOINING OF ADJACENT DAMAGED AREAS IS PREFERRED OVER MULTIPLE
REPAIRS SEPARATED BY SHORT DISTANCES OF ORIGINAL CONCRETE.
B. REVIEW AREA EXTENTS WITH ENGINEER.
C. SAWCUT PERIMETER OF REPAIR. DEPTH OF CUT SHALL BE 1/8-INCH MINIMUM AND SHALL NOT
BE DEEPER THAN COVER OVER EMBEDDED REINFORCING. DO NOT CUT OR OTHERWISE
DAMAGE EXISTING EMBEDDED ITEMS. THE EDGES OF THE REPAIR AREA SHALL BE CUT
PERPENDICULAR OR SLIGHTLY UNDERCUT TO AVOID FEATHER EDGING OF THE REPAIR
MATERIAL. DO NOT OVERCUT AT CORNERS OF REPAIR.
D. PERFORM CONCRETE REMOVAL DOWN TO SOUND, CLEAN CONCRETE. SURFACES SHALL BE
FREE OF BOND INHIBITING MATERIALS SUCH AS OILS, HARDENED EPOXY, FRACTURED AND
LOOSE OR DELAMINATED CONCRETE. CONCRETE SURFACES SHALL BE ROUGHENED TO A
PROFILE OF 1/4-INCH TO AID IN BOND AND MECHANICAL INTERLOCK OF REPAIR (ICRI CONCRETE SURFACE PROFILE (CSP) NO. 7 OR HIGHER, PER ICRI GUIDELINE NO. 310.2R). THICKNESS OF
REPAIR SHALL BE EQUAL OR GREATER THAN THE MINIMUM THICKNESS OF REPAIR MATERIALS.
E. WHERE REINFORCEMENT IS ENCOUNTERED IN THE REPAIR AREA AND ONE-QUARTER OR MORE
OF THE BAR DIAMETER IS EXPOSED, CONCRETE REMOVAL SHALL CONTINUE UNTIL A GAP 1/4"
LARGER THAN THE LARGEST AGGREGATE AND MINIMUM OF 3/4-INCH IS PROVIDED BENEATH
THE BAR. WHERE CORROSION IS IDENTIFIED THE FULL EXTENT OF THE CORROSION SHALL BE
EXPOSED.
F. CLEAN REINFORCING AS NECESSARY - REMOVE ALL HEAVY RUST AND SCALE. WHERE
PROTECTIVE COATINGS ARE SPECIFIED, FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR
SURFACE PREPARATION. ATTENTION SHALL MADE TO CLEAN ALL STEEL SURFACES INCLUDING
THE FAR SIDE OF EMBEDDED REINFORCING STEEL. WHERE REINFORCING IS HEAVILY
CORRODED AND DIAMETER IS REDUCED, REVIEW CONDITIONS WITH ENGINEER FOR REPAIR.
G. SECURE ANY LOOSE REINFORCING STEEL WITH TIE WIRE OR OTHER BAR SUPPORT SYSTEM TO
PREVENT DISPLACEMENT DURING CONCRETE PLACEMENT.
H. WASH CONCRETE SURFACE USING HIGH PRESSURE WATER SPRAY TO REMOVE RESIDUAL
DUST, DEBRIS, FRACTURED CONCRETE, AND CONTAMINANTS THAT PREVENT PROPER
BONDING. DO NOT ALLOW WASH PARTICULATE SLURRY TO SETTLE OR REMAIN ON PREPARED
SURFACES.
I. APPLY A SCRUB COAT OF REPAIR MATERIAL TO PREPARED SURFACE FILLING ALL PORES AND VOIDS. SURFACE OF SUBSTRATE SHALL BE IN A SATURATED SURFACE DRY CONDITION AT TIME
OF PLACEMENT.
J. PLACE REPAIR MATERIAL IN LIFTS WITHIN THICKNESS ALLOWED BY MANFACTURER. ENSURE
COMPLETE FILLING OF VOIDS BEHIND ANY INCLUDED REBAR. PACKING OF MATERIAL MAY BE
REQUIRED. INTERMEDIATE LIFTS SHALL BE INTENTIALLY ROUGHENED AS INDICATED BY
MANUFACTURER. FINAL REPAIR LIFTS SHALL MATCH THE HEIGHT AND TEXTURE OF ADJACENT
SURFACES.
K. PROTECT REPAIR MATERIAL AND CURE FOLLOWING MANUFACTURER'S RECOMMENDATIONS.
L. VISUALLY EXAMINE REPAIR CONFIRMING THOROUGH CONSOLIDATION AND ADEQUATE BONDING
TO SUBSTRATE. HAMMER SOUND TO CHECK FOR VOIDS OR DELAMINATIONS. IF REQUIRED BY
ENGINEER, PERFORM UNIAXIAL BOND TEST ON CORE DRILLED THROUGH THE REPAIR INTO THE
SUBSTRATE IN ACCORDANCE WITH ACI 503R APPENDIX.
M. PREPARE SURACE FOR SPECIFIED FINISHES AND CONFIRM APPEARANCE ACCEPTABLE TO THE
ARCHITECT AND OWNER.
(E) VOID OR DAMAGE
(E) CONCRETE ELEMENT
PROVIDE GAP 1/4" LARGER
THAN THE LARGEST
AGGREGATE & MINIMUM OF
3/4" TYP
ENSURE COMPLETE FILLING
BEHIND ANY INCLUDED
REINFORCING
EDGES SHALL BE NORMAL TO
THE SURFACE OR SLIGHTLY
UNDERCUT
PREPARE SURFACES FOR
PLACEMENT
CLEAN & REPAIR OR SUPPLEMENT
REINF WHERE NECESSARY
APPLY MATERIAL IN LIFTS
MEETING THE MANUFACTURER'S
THICKNESS REQUIREMENTS
(E) CONCRETE
ELEMENT
INJECTION PORT
(E) CRACK, PARTIAL
THICKNESS
INJECTION PORT
(E) CRACK, THROUGH
THICKNESS
PROVIDE INJECTION
PORTS IF INJECTING
FROM BOTH SIDES OF
ELEMENT
CAP SEAL WHERE FAR
SIDE IS ACCESSIBLE
MATERIALS:
A. RESIN (CONFORM TO ASTM C-881): SIKA SIKADUR 35 HI-MOD LV, HILTI CI 060 EP, SIMPSON CI-LV, OR APPROVED EQUAL.
B. SURFACE SEALER: SIKADUR INJECTION GEL, HILTI CI 070 EP, SIMPSON CIP-LO, OR APPROVED
EQUAL.
C. PORTING DEVICES: AS REQUIRED FOR EITHER MANUAL OR AUTOMATED APPLICATION. DEVICES
SHALL BE COMPATIBLE WITH EQUIPMENT USED.
NOTES:
1. REFER TO ACI RAP-1 "STRUCTURAL CRACK REPAIR BY EPOXY INJECTION" FOR BACKGROUND AND
DETAILED DESCRIPTION OF THIS METHOD.
2. CONTRACTOR QUALIFICATIONS: CONTRACTOR SHALL BE QUALIFIED IN THE FIELD OF CONCRETE
REPAIR AND PROTECTION WITH A SUCCESSFUL TRACK RECORD OF 5 YEARS OR MORE.
CONTRACTOR SHALL MAINTAIN QUALIFIED PERSONNEL WHO HAVE RECEIVED PRODUCT TRAINING
BY A MANUFACTURER'S REPRESENTATIVE.
3. INSTALL MATERIALS IN ACCORDANCE WITH ALL SAFETY, WEATHER CONDITIONS, MATERIAL
HANDLING AND INSTALLATION PROCEDURES REQUIRED BY THE MANUFACTURER, OR AS MODIFIED BY APPLICABLE RULES AND REGULATIONS OF LOCAL, STATE, AND FEDERAL AUTHORITIES HAVING
JURISDICTION. CONSULT MATERIAL SAFETY DATA SHEETS FOR COMPLETE HANDLING
RECOMMENDATIONS.
4. EXECUTION:
A. PRIOR TO REPAIR, REVIEW CRACKING TO IDENTIFY IF THROUGH-THICKNESS CRACKING MAY
EXIST.
B. AREAS TO BE SEALED MUST BE CLEAN AND FREE OF CONTAMINANTS AND MOISTURE.
C. ROUT CRACKS WHERE NECESSARY TO REMOVE LOOSE MATERIAL AT EDGES.
D. SET PORTING DEVICES, SPACE APPROPRIATELY TO ALLOW MAXIMUM FILLING OF CRACKS .
E. APPLY SURFACE SEALER. SEAL THE FAR SIDE OF CRACKS THAT EXTEND THROUGH THE
ELEMENT. PROTECT REPAIR AREAS FOR POTENTIAL LEAKS.
F. FOLLOWING SUFFICIENT CURE OF SURFACE SEALER, INJECT EPOXY RESIN UNTIL REFUSAL. FILL
CRACKS WHEN THEY ARE WIDEST - DURING THE COOLEST PART OF THE DAY TO MAXIMIZE
MATERIAL FILL.
G. FOLLOWING CURE OF RESIN, COMPLETELY REMOVE PORTS AND CAP SEAL.
H. CONFIRM SUCCESSFUL INJECTION USING CORES OR NON-DESTRUCTIVE EVALUATION.
I. PREPARE SURFACE FOR SPECIFIED FINISHES AND CONFIRM APPEARANCE ACCEPTABLE TO THE
ARCHITECT AND OWNER.
J. REMOVE ANY EPOXY ON CONCRETE SURFACE TO MATCH EXISTING FINISH -
MOCK-UP FINISH FOR ARCHITECT APPROVAL PRIOR TO PROCEEDING WITH WORK.
DETAIL
S102
3" = 1'-0"1
VERT OR OVERHEAD
CONC SURFACE REPAIR
300SD813 - Vertical or Overhead Concrete Surface Repair
S
S
T A T E O F C A L I F O R N I A
STRUCTURAL
R
EFORP
DE
R E
T
SI
G E
S I N
EN
G
I N E
E R
O
AL
600 Q Street, Suite 100 Sacramento, CA 95811 www.nachtlewis.com 916.329.4000
600 Q STREET, SUITE 200
SACRAMENTO, CA 95811
916 443 0303
B u e h le r P ro je c t
-0 e v it
N
AP
A C
O U
N
TY
N
AP
A
LI
BR
AR
Y
BU
IL
D
IN
G
M
AI
N
TE
N
AN
C E
O N
E-
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
IN
C H
T
W
EN
TY
F
EE
T
O
N E-
EI
G
H
TH
IN
C
H
O N
E
FO
O T
O
N E-
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T
O N
E
IN
C H
O
N E
FO
O
T
TH
R
EE
-Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
O N
E- H
AL
F
IN
C
H
O N
E
FO
O T
O
N E
AN
D
O N
E- H
AL
F
IN
C
H
O N
E
FO
O T
ARCHITECT
REVISIONS
SHEET TITLE
SHEET NO.
JOB NO.: Y2505.00
DATE: 02/13/2026
NO. DESCRIPTION DATE
C oo m bs
S t, N ap a, C
A
CONSULTANT
CONSTRUCTION DOCUMENTS
AGENCY APPROVAL
BRIAN S.
WIENS
No. 6259
TYPICAL STRUCTURAL
REPAIR NOTES AND DETAILS
S102
DETAIL NO SCALE
S102
CRACK REPAIR BY
PRESSURE INJECTION
300SD801
Final, Construction Intent Napa Library
April 08, 2025
Program: 24-414
DRAWINGS CHECKED BY:
Program Management
Design
Production
Installation
NOTE:
This document is used for coordinating signage review and feedback.
Fabricator is not to adjust existing work, Page will have note of existing elements
01/31/2025
02/10/2025
04/03/2025
04/08/2025
DATE: Revision Notes:Rev:
Draft 1
Draft 1 Rev. 1
Final
Revised
- Initial Release
- New layout with new color options Added different options for Building Identification Added two different signage family options.
- Added new sign INF.04 Adjusted Time on ID.04 & INF.02 with added copy Adjusted Arrow on DIR.02 Removed DIR.03, INF.01, IN.03 Updated Location Map
- Revised ID.04 to have message in top white panel, and removed from bottom panel
1.01 Cover Sheet
2024 GNU Group. All rights reserved.
CONSTRUCTION
INTENT
Do Not Use As Fabrication Drawing
EQ
As Noted03.07.2025
1.02
24-414
580 Coombs St, Napa, CA
Revised - 02.10.2025 EQ
Final - 04-03-2025 EQ
Typography Symbols and Colors
050212CIV6
Original Issue: Scale:
© 2012 GNU Group. All rights reserved.
Title:
Sheet:
Program Number: Drawn By:
Revisions / Bulletins:
Typography, Symbols and Colors
06.19.2013 As Noted
A.0
CONSTRUCTION
INTENT
Do Not Use As Fabrication Shop
Program Location:
13-NCPW-0001
1. 7.8.13 KS
KS
Approval:
Checked by:
Prepared By:
580 Coombs Napa, CA
Typography
DIN BOLD
Napa County Library Logo Mark
Napa County Library Logo Mark w/ Copy
ArrowsNapa County Seal abcdefghijklmnopqrstuvwxyz
ABCDEFGHIJKLMNOPQRSTUVWXYZ
0123456789!?”
HELVETICA 57 CONDENSED
abcdefghijklmnopqrstuvwxyz
ABCDEFGHIJKLMNOPQRSTUVWXYZ
0123456789!?”
Symbols
Colors
Bruni Green Met.
Matthews Paint MP43443, Satin finish
C1 WHITE 3M Opaque 7725-10, 7125-10V1
Esmerelda Green Met.
Matthews Paint MP23420 Satin finish
C2
WHITE Matthews Paint MP31645, Satin finish, or equivalent
C4
Sea Reflections Matthews Paint MP07030 Satin finish
C3
PAINT VINYL
FEDERAL BLUE
595B -15090 Satin finish, or equivalent
C5
FABRICATOR MUST PRESENT COLOR SAMPLES
PRIOR TO FABRICATION.
NAPA COUNTY LIBRARY | 580 Coombs St.
1.03 Location
INTENT
Do Not Use As Fabrication Drawing
EQ
As Noted03.07.2025
1.04
24-414
580 Coombs St, Napa, CA
Revised - 02.10.2025 EQ
Final - 04-03-2025 EQ
ID.01
Entry Monument ID
050212CIV6
Original Issue: Scale:
© 2012 GNU Group. All rights reserved.
Title:
Sheet:
Program Number: Drawn By:
Revisions / Bulletins:
ID.01
Entry Monument ID
06.19.2013 As Noted
1.0
CONSTRUCTION
INTENT
Do Not Use As Fabrication Shop
Program Location:
13-NCPW-0001
1. 7.8.13 KS
2. 7.26.13 KS
KS
Approval:
Checked by:
Prepared By:
580 Coombs Napa, CA
4' -6
5 1/4"
9'-0"
580 Coombs
A Commitment to ServiceA Tradition of Stewardship
Enriching lives with books and information
2' -1
7 / 8"
3 /
4"
6' -8
1 FRONT VIEW
Scale: 3/4” = 1’-0”
3 TOP VIEW
Scale: 3/4” = 1’-0”
2 SIDE VIEW
Scale: 3/4” = 1’-0”
2" R.
2" R.
2' -1
1 / 8"
DRAWING NOTES:
These documents are for design intent and shall be used only as a guide to produce the finished sizes, appearances and functions shown. The sign fabricator shall be responsible to meet all CBC Title 24 code compliance specifications for tactile letter spacing, tactile letter dimensioning, and braille dimensioning. The fabricator/ contractor shall be responsible for all structural, electrical, mechanical, foundation engineering, for all dimensions and familiarity with the site and the conditions it presents. GNU Group must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted to GNU Group for approval prior to proceeding with fabrication. All copy shall be proofread by client andany legal requirements checked by client’s legal department.
Sign Specifications:
1 – Dimensional Logo 6” thk fabricated aluminum, Painted C3, fully welded and reinforced
2 – Dimensional Logo 8“ thk fabricated aluminum, Painted C1,fully welded and reinforced
3 – Fabricated Sign Panels 1 1/2” thk, top panel painted C4, bottom panel painted C2, integrated with sign posts
4 – Dimensional Letters 1/2“ thick aluminum letters painted C1 and C3
5 – Digitally printed Copy Direct digitally printed copy
6 – Dimensional Plaque 1/8” thk aluminum, Painted, w/ first surface direct digital print application
General Notes:
Quantity = (1)
Digital printed elements to be protected with Clear Coat, Satin Finish
1/
2"
EXISTING ELEMENT
120˚
8"
1/ 2"
6" 8 3/8"
2'-0 1/8"
INTENT
Do Not Use As Fabrication Drawing
EQ
As Noted03.07.2025
1.05
24-414
580 Coombs St, Napa, CA
Revised - 02.10.2025 EQ
Final - 04-03-2025 EQ
ID.02
Building ID
050212CIV6
Original Issue: Scale:
© 2012 GNU Group. All rights reserved.
Title:
Sheet:
Program Number: Drawn By:
Revisions / Bulletins:
ID.02
Building ID
As Noted
2.0
Do Not Use As Fabrication Shop
Program Location:
1. 7.26.13 KS
Approval:
Checked by:
Prepared By:
580 Coombs Napa, CA
06.19.2013
CONSTRUCTION
INTENT
13-NCPW-0001 KS
ID.02
Building ID
1 1/2"
5' -0
4' -8
1' -0
3 1/4"
10 3/4"
9 1/8"
1 FRONT VIEW
Scale: 1/2” = 1’-0”
3 PLACEMENT DETAIL
Scale: NTS
2 SIDE VIEW
Scale: 1/2” = 1’-0”
CL Centered over entry doors
DRAWING NOTES:
These documents are for design intent and shall be used only as a guide to produce the finished sizes, appearances and functions shown. The sign fabricator shall be responsible to meet all CBC Title 24 code compliance specifications for tactile letter spacing, tactile letter dimensioning, and braille dimensioning. The fabricator/ contractor shall be responsible for all structural, electrical, mechanical, foundation engineering, for all dimensions and familiarity with the site and the conditions it presents. GNU Group must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted to GNU Group for approval prior to proceeding with fabrication. All copy shall be proofread by client andany legal requirements checked by client’s legal department.
Sign Specifications:
1 – Dimensional Logo Painted C1 & C3, fabricated aluminum
2 – Dimensional Letterforms Painted C1 & C3, fabricated aluminum, mechanically fastened to wall surface
General Notes:
Quantity = (1)
Fabrication Note:
Removal requires patch and paint prior to install of new logo and letterforms
INTENT
Do Not Use As Fabrication Drawing
EQ
As Noted03.07.2025
1.06
24-414
580 Coombs St, Napa, CA
Revised - 02.10.2025 EQ
Final - 04-03-2025 EQ
ID.03
Entry Monument ID / Kiosk
050212CIV6
Original Issue: Scale:
© 2012 GNU Group. All rights reserved.
Title:
Sheet:
Program Number: Drawn By:
Revisions / Bulletins:
ID.03
Entry Monument ID /Kiosk
As Noted
3.0
Do Not Use As Fabrication Shop
Program Location:
1. 7.26.13 KS
Approval:
Checked by:
Prepared By:
580 Coombs Napa, CA
06.19.2013
CONSTRUCTION
INTENT
13-NCPW-0001 KS
Enriching lives with books and information
7' -3
9' -0
7 / 8"
3' -2
6"
1' -1
3 / 8"
1' -4
1 / 2"
1 3/8" R.
1 3/8" R.
1 FRONT VIEW
Scale: 3/4” = 1’-0”
3 TOP VIEW
Scale: 3/4” = 1’-0”
2 SIDE VIEW
Scale: 3/4” = 1’-0”
DRAWING NOTES:
These documents are for design intent and shall be used only as a guide to produce the finished sizes, appearances and functions shown. The sign fabricator shall be responsible to meet all CBC Title 24 code compliance specifications for tactile letter spacing, tactile letter dimensioning, and braille dimensioning. The fabricator/ contractor shall be responsible for all structural, electrical, mechanical, foundation engineering, for all dimensions and familiarity with the site and the conditions it presents. GNU Group must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted to GNU Group for approval prior to proceeding with fabrication. All copy shall be proofread by client andany legal requirements checked by client’s legal department.
Sign Specifications:
1 – Dimensional Logo 5” thk fabricated aluminum, Painted C3, fully welded and reinforced
2 – Dimensional Logo 6” thk fabricated aluminum, Painted C1, fully welded and reinforced
3 – Fabricated Sign Panel 1” thk fabricated aluminum, Painted C4, fully welded and reinforced
4 – Dimensional Letters 1/2“ thick aluminum letters painted C1 and C3
5 – Typography Digitally printed copy C1 & C3
6 – Info Holder Non-illuminated enclosed weatherproof case w/ hinged, framed lockable door and clear lexon face, Painted C2. Vinyl impregnated cork-board (weather proof, water tight seal)
General Notes:
Quantity = (1) Double Sided Sign Element
Digital printed elements to be protected with Clear Coat, Satin Finish
2'-0"
4"
EXISTING ELEMENT
5"
6"
INTENT
Do Not Use As Fabrication Drawing
EQ
As Noted03.07.2025
1.07
24-414
580 Coombs St, Napa, CA
Revised - 02.10.2025 EQ
Final - 04-03-2025 EQ
ID.04
Parking Entry ID
Revised - 04.08.2025 EQ
050212CIV6
Original Issue: Scale:
© 2012 GNU Group. All rights reserved.
Title:
Sheet:
Program Number: Drawn By:
Revisions / Bulletins:
ID.04
Parking Entry ID
As Noted
4.0
Do Not Use As Fabrication Shop
Program Location:
1. 7.26.13 KS
Approval:
Checked by:
Prepared By:
580 Coombs Napa, CA
06.19.2013
CONSTRUCTION
INTENT
13-NCPW-0001 KS
1/
2" 3'
-0
3'-8"
4"
2'-4 1/2"
1/
2"
6"
5' -3
/4
4' -1
0"
1' -1
/2
Mon: 9am - 8pm Tue: 9am - 8pm Wed: 9am - 8pm Thur: 9am - 8pm Fri: 10am - 6pm Sat: 10am - 6pm Sun: 1pm - 5pm
Additional Parking in the Garage
2" See you soon! ¡Nos vemos pronto!
1 FRONT VIEW - SIDE A
Scale: 3/4” = 1’-0”
3 TOP VIEW
Scale: 3/4” = 1’-0”
2 FRONT VIEW - SIDE B
Scale: 3/4” = 1’-0”
11 3/8" R.
1 3/8" R.
EXISTING ELEMENT
DRAWING NOTES:
These documents are for design intent and shall be used only as a guide to produce the finished sizes, appearances and functions shown. The sign fabricator shall be responsible to meet all CBC Title 24 code compliance specifications for tactile letter spacing, tactile letter dimensioning, and braille dimensioning. The fabricator/ contractor shall be responsible for all structural, electrical, mechanical, foundation engineering, for all dimensions and familiarity with the site and the conditions it presents. GNU Group must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted to GNU Group for approval prior to proceeding with fabrication. All copy shall be proofread by client andany legal requirements checked by client’s legal department.
Sign Specifications:
1 – Top Sign Panel 1” thk fabricated aluminum, Painted C4, mechanically fastened to sign posts
2 – Graphics Digitally printed, color to match C1 & C3
3 – Vinyl Graphics Vinyl, to match V1
4 – Sign Panel 1” thk fabricated aluminum, Painted C2, mechanically fastened to sign posts
General Notes:
Quantity = (2) See copy list for content Double Sided Sign Element
Digital printed elements to be protected with Clear Coat, Satin Finish
3"
3"
2" 1"
Hours
INTENT
Do Not Use As Fabrication Drawing
EQ
As Noted03.07.2025
1.08
24-414
580 Coombs St, Napa, CA
Revised - 02.10.2025 EQ
Final - 04-03-2025 EQ
DIR.01
Vehicular Directional
050212CIV6
Original Issue: Scale:
© 2012 GNU Group. All rights reserved.
Title:
Sheet:
Program Number: Drawn By:
Revisions / Bulletins:
DIR.01
Vehicular Directional
As Noted
5.0
Do Not Use As Fabrication Shop
Program Location:
1. 7.8.13 KS
2. 7.26.13 KS
Approval:
Checked by:
Prepared By:
580 Coombs Napa, CA
06.19.2013
CONSTRUCTION
INTENT
13-NCPW-0001 KS
Returns
1/
2" 3'
-0
3'-8"
4"
2'-4 1/2"
1/
2"
6" 3"
5' -3
/4
4' -1
0"
1' -1
/2
Returns
1 FRONT VIEW - SIDE A
Scale: 3/4” = 1’-0”
3 TOP VIEW
Scale: 3/4” = 1’-0”
2 FRONT VIEW - SIDE B
Scale: 3/4” = 1’-0”
DRAWING NOTES:
These documents are for design intent and shall be used only as a guide to produce the finished sizes, appearances and functions shown. The sign fabricator shall be responsible to meet all CBC Title 24 code compliance specifications for tactile letter spacing, tactile letter dimensioning, and braille dimensioning. The fabricator/ contractor shall be responsible for all structural, electrical, mechanical, foundation engineering, for all dimensions and familiarity with the site and the conditions it presents. GNU Group must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted to GNU Group for approval prior to proceeding with fabrication. All copy shall be proofread by client andany legal requirements checked by client’s legal department.
1"
Sign Specifications:
1 – Top Sign Panel 1” thk fabricated aluminum, Painted C4, mechanically fastened to sign posts
2 – Graphics Digitally printed, color to match C1 & C3
3 – Vinyl Graphics Vinyl, to match V1
4 – Sign Panel 1” thk fabricated aluminum, Painted C2, mechanically fastened to sign posts
General Notes:
Quantity = (2) See copy list for content Double Sided Sign Element
Digital printed elements to be protected with Clear Coat, Satin Finish
1 3/8" R.
1 3/8" R.
EXISTING ELEMENT
6" 3"
INTENT
Do Not Use As Fabrication Drawing
EQ
As Noted03.07.2025
1.09
24-414
580 Coombs St, Napa, CA
Revised - 02.10.2025 EQ
Final - 04-03-2025 EQ
DIR.01
Vehicular Directional
Layout 2
050212CIV6
Original Issue: Scale:
© 2012 GNU Group. All rights reserved.
Title:
Sheet:
Program Number: Drawn By:
Revisions / Bulletins:
DIR.01
Vehicular Directional Layout 2
As Noted
5.1
Do Not Use As Fabrication Shop
Program Location:
1. 7.26.13 KS
Approval:
Checked by:
Prepared By:
580 Coombs Napa, CA
06.19.2013
CONSTRUCTION
INTENT
13-NCPW-0001 KS
Deliveries
Book Donations
Library Use Only
1/
2" 3'
-0
3'-8"
4"
2'-4 1/2"
1/
2"
5' -3
/4
4' -1
0"
1' -1
/2
Sign Specifications:
1 – Top Sign Panel 1” thk fabricated aluminum, Painted C4, mechanically fastened to sign posts
2 – Graphics Digitally printed, color to match C1 & C3
3 – Vinyl Graphics Vinyl, to match V1
4 – Sign Panel 1” thk fabricated aluminum, Painted C2, mechanically fastened to sign posts
General Notes:
Quantity = (2) See copy list for content Double Sided Sign Element
Digital printed elements to be protected with Clear Coat, Satin Finish
1 3/8" R.
1 3/8" R.
EXISTING ELEMENT
1 FRONT VIEW - SIDE A
Scale: 3/4” = 1’-0”
3 TOP VIEW
Scale: 3/4” = 1’-0”
2 FRONT VIEW - SIDE B
Scale: 3/4” = 1’-0”
1"
DRAWING NOTES:
These documents are for design intent and shall be used only as a guide to produce the finished sizes, appearances and functions shown. The sign fabricator shall be responsible to meet all CBC Title 24 code compliance specifications for tactile letter spacing, tactile letter dimensioning, and braille dimensioning. The fabricator/ contractor shall be responsible for all structural, electrical, mechanical, foundation engineering, for all dimensions and familiarity with the site and the conditions it presents. GNU Group must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted to GNU Group for approval prior to proceeding with fabrication. All copy shall be proofread by client andany legal requirements checked by client’s legal department.
3" 3"
2"
INTENT
Do Not Use As Fabrication Drawing
EQ
As Noted03.07.2025
1.10
24-414
580 Coombs St, Napa, CA
Revised - 02.10.2025 EQ
Final - 04-03-2025 EQ
DIR.02
Pedestrian Directional
050212CIV6
Original Issue: Scale:
© 2012 GNU Group. All rights reserved.
Title:
Sheet:
Program Number: Drawn By:
Revisions / Bulletins:
DIR.02
Pedestrian Directional
As Noted
6.0
Do Not Use As Fabrication Shop
Program Location:
1. 7.26.13 KS
Approval:
Checked by:
Prepared By:
580 Coombs Napa, CA
06.19.2013
CONSTRUCTION
INTENT
13-NCPW-0001 KS
4" 3'
-3
/4
1' -8
5" 2"
1/
2"
2'-0"
1'-4"
5' -5
3 1/2"
1 3/8" R.
Main Entrance
1 FRONT VIEW - SIDE A
Scale: 1” = 1’-0”
3 TOP VIEW
Scale: 1” = 1’-0”
2 FRONT VIEW - SIDE B
Scale: 1” = 1’-0”
3/4" R.
EXISTING ELEMENT
D…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .