Plans.pdf
PDF 3 MB Posted
- Attached to
- Broadmore Road Sewer Rehabilitation
- Solicitation number
- 85583
- Issued by
- Prince George's County, Maryland
About this file
This is a project plan document prepared by the Washington Suburban Sanitary Commission (WSSC) Pipeline Design Division for the Broadmore Road Sewer Rehabilitation project located in the Paint Branch Basin within Prince George's County, Maryland. The project encompasses the repair, rehabilitation, and replacement of approximately 1,228 linear feet of defective sewer mains, 737 linear feet of defective sewer laterals, and seven manholes across multiple locations including Broadmore Road, Kilgore Road, E. Randolph Road, Morningside Drive, and Smith Village Road. Primary work activities include upsizing existing 6-inch pipes to 8-inch polyvinyl chloride (PVC) piping, renewing sanitary house connections with 4-inch PVC laterals, installing cleanouts, and replacing deteriorated asbestos cement pipe. Materials specified include 1,228 linear feet of 8-inch PVC sewer main, approximately 737 linear feet of 4-inch PVC laterals, multiple 8-inch by 4-inch tees and wyes, and 48-inch diameter precast concrete manholes. The project encompasses a total disturbance area of approximately 0.61 acres (26,721 square feet). Sealed responses must be submitted electronically through WSSC's eProcurement Portal by 2:00 pm on Thursday, December 18, 2025, with a question submission deadline of December 2, 2025. The contract requires a completion timeframe of 140 calendar days from Notice to Proceed, with liquidated damages assessed at $925.00 per day for delays.
The project is funded through the Maryland Department of the Environment's State Revolving Fund (SRF) Loan program, requiring contractor compliance with Davis-Bacon wage rates, American Iron and Steel (AIS) product requirements, and the Build America Buy America Act (BABA). Bidders must establish a 26 percent Minority Business Enterprise (MBE) and Small Local Business Enterprise (SLBE) subcontracting goal, with African American firms counting fully toward the goal and Hispanic American and Women-Owned firms counting at 13 percent and 14 percent respectively. Required bid documentation includes a 5 percent bid guarantee, performance and payment bonds totaling 100 percent of the contract value, and evidence of commercial general liability insurance with minimum $1,000,000 per occurrence limits. Key personnel must demonstrate minimum three years of experience in open cut underground utility construction with certified traffic control and erosion and sediment control personnel. The project requires compliance with permitting requirements from multiple jurisdictions including Maryland State Highway Administration, Prince George's County, Montgomery County, Maryland National Capital Park and Planning Commission, Maryland Forest Service, and several incorporated municipalities (City of Bowie, City of College Park, City of Gaithersburg, City of Rockville, City of Laurel, and City of Cheverly). Contractors must notify Miss Utility at 1-800-257-7777 at least 72 hours prior to excavation and maintain existing sewer flow through bypass pumping operations until new sewers are installed and placed into service.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROSEMERE
AVENUE
LA
U
X S
T R
E E
T
M A
P
LE
S T
R E
E T
MULLINS
STREET
RI
G
DA
LE
TE
RR
AC
E
LEISTERDRIVE
CHILTON
DRIVE
E. R A
N D
O
LPH
R O
A D
BROADMORE
CIRCLE
BUCCANEER
COURT
WINHALL WAY
HOLLYWOOD
AVENUE
TAMARACK
ROAD
K
IL
G O
R E
R O
A D
B R
O A
D M
O R
E
R O
A D
M O
RN
IN
G
SIDE
DRIVE
AUTUM
N
DRIVE
B U
C C
A N
EER
R O
A D
CLIFTON
ROAD
CANNON
ROAD
ALLERTO
N
LAN
E
C H
IL
T
O N
C
IR
C
LE
B
LA
K E
R O
A D
MONTCLAIR DRIVE
LA
URI
E
DR
IV
E
BI
LL
IN
G
TO
N
R O
AD
EASTBOURNE
PLA
CE
WASHINGTON SUBURBAN SANITARY COMMISSION
BROADMORE ROAD SEWER REHABILITATION
ABBREVIATIONS:
SAN SANITARY SEWER
MH MANHOLE
ST. STREET
AVE. AVENUE
US/DS UPSTREAM/DOWNSTREAM
HC HOUSE CONNECTION
SHC SANITARY HOUSE CONNECTION
EXIS EXISTING
INV. INVERT
T TRANSITE
PVC POLYVINYL CHLORIDE
CI CAST IRON
C CONCRETE
DI DUCTILE IRON
W WATER MAIN
STM STORM SEWER
GAS GAS LINE
VICINITY MAP
SCALE: 1" = 500'
ENGINEER:
MONTGOMERY CO.
NO200'S 217NE01, 217NE02
OF
DATE
DATE STARTED
DATE FINALED
Drawing No.
FINALED BY
DATE COMPLETED
TYPE MANHOLES
TYPE PIPE W.
Description
P.G.CO.D.P.W.&T.
SED. CONTROL
CONTRACT MANAGER
INSPECTOR
CONTRACTOR
L & G
AS BUILT DATA
TOWN NOTIFICATION
STATE HGWY. ADM.
STATE BD. HEALTH
PERMIT REQUIREMENTS
M.N.C.P.&P.C.
WETLANDS / WATERWAYS
TREE
DATE REVISIONS
S.
THESE DOCUMENTS CONTAIN
PRIVILEGED AND CONFIDENTIAL
INFORMATION WHICH SHALL NOT
BE REDISTRIBUTED WITHOUT
PRIOR WSSC APPROVAL
FOR LOCATION OF UTILITIES CALL 8-1-1 OR 1-800-257-7777
OR LOG ON TO www.call811.com or www.missutility.net 72
HOURS IN ADVANCE OF ANY WORK IN THIS VICINITY
*TO BE ACQUIRED BY APPLICANT
DRAWING INDEX
PIPELINE DESIGN DIVISION
DATE DIVISION MANAGER
VE
R
IF
Y
SC
AL
E
- B
AR
IS
O N
E
IN
C H
O N
O R
IG
IN
AL
D
R
AW
IN
G
IF
N
O T
O N
E
IN
C H
O N
T H
IS
S
H
EE
T, A
D
JU
ST
S
C
AL
ES
A
C C
O R
D
IN
G
LY
M.D. D.O.E. - WMA
SECTION MANAGER
SEWER INFRASTRUCTURE SECTION
REQ'D
NOT REQ'D
NOT REQ'D
NOT REQ'D
NOT REQ'D
REQ'D
REQ'D
NOT REQ'D
NOT REQ'D
TASK ORDER NO. 212
SANITARY SEWER REHABILITATION (SSR) MDE FUNDED PROJECT
COVER SHEET
PAINT BRANCH BASIN
PRIOR TO ANY EXCAVATION
CALL MISS UTILITY: 1-800-257-7777
RESTORATION SCHEDULE
LOCATION GRADING TYPE RESTORATION TYPE
ALL AREAS I "A" OR PAVING
RESTORATION TYPE:
· TYPE A: SOD FOR ESTABLISHED LAWNS, PARK LAWNS, AND FREQUENTLY
MOWED PUBLIC SPACES.
· TYPE B: SOD FOR SODDED SWALES
· TYPE C: SURGE STONE FOR SEEDED AND STONE LINED SWALES
· TYPE D: SEED FOR IMPROVED AREAS
· TYPE E: SEED FOR UNIMPROVED AND OUTFALL AREAS
· TYPE F: DEVELOPMENT SITES WITH EXISTING STABILIZATION OF
TEMPORARY MULCH OR PLANTED SEED.
SEE GENERAL CONDITIONS & STANDARD SPECIFICATIONS ON PG.02315-2 AND
02920-1
GRADING TYPE:
DESIGNATIONS SETTLEMENT LIMITATIONS LOCATIONS
TYPE I 0.05 FOOT PAVED AREAS AND PUBLIC
RIGHTS OF WAY
TYPE II WITH POSITIVE DRAINAGE UNIMPROVED AREAS
TYPE III 0.10 FOOT NONPAVED IMPROVED
AREAS
TYPE IV 0.00 FOOT WETLANDS OR WETLANDS
BUFFER
SEWER BYPASS REQUIRED:
THE CONTRACTOR SHALL MAINTAIN FLOW OF ALL EXISTING SEWERS UNTIL NEW
SEWERS HAVE ALL BEEN INSTALLED AND PLACED IN SERVICE. A BYPASS
PUMPING PLAN IS TO BE SUBMITTED IN ACCORDANCE WITH WSSC STANDARD
SPECIFICATION 02960.
TOWN NOTIFICATIONS (IF APPLICABLE):
CITY OF BOWIE
CONTACT THE DIRECTOR OF PUBLIC WORKS FOR THE CITY OF BOWIE AT
301-809-2344, 48 HOURS PRIOR TO THE START OF CONSTRUCTION.
CITY OF COLLEGE PARK
CONTACT THE CITY ENGINEER FOR THE CITY OF COLLEGE PARK AT 240-508-7958
FOR ATTENDANCE AT THE PRE-CONSTRUCTION MEETING AND ALL PROGRESS
AND FIELD MEETINGS DURING CONSTRUCTION.
CITY OF GAITHERSBURG
CONTACT THE DIRECTOR OF PUBLIC WORKS FOR THE CITY OF GAITHERSBURG
AT 301-258-6370, 48 HOURS PRIOR TO THE START OF CONSTRUCTION FOR
NOTIFICATION PURPOSES ONLY.
CITY OF ROCKVILLE
BEFORE BEGINNING CONSTRUCTION CONTACT CITY OF ROCKVILLE UTILITY AT
240-314-8567 AT LEAST 48 HOURS PRIOR TO EXCAVATION.
CITY OF LAUREL
CONTACT THE DIRECTOR OF PUBLIC WORKS, CITY OF LAUREL, AT 301-725-0088,
48 HOURS PRIOR TO THE START OF CONSTRUCTION FOR NOTIFICATION
PURPOSES ONLY.
CITY OF CHEVERLY
CONTACT THE CITY OF CHEVERLY PUBLIC WORKS DEPARTMENT, AT
301-773-2666 TO OBTAIN A "SPECIAL UTILITY PERMIT" PRIOR TO START OF
CONSTRUCTION.
PRINCE GEORGE'S COUNTY NOTE (FOR ALL PROJECTS IN PG CO.)
CONTACT THE PRINCE GEORGE'S COUNTY DEPARTMENT OF PUBLIC WORKS &
TRANSPORTATION, AT 301-324-2710, 48 HOURS IN ADVANCE OF STARTING
CONSTRUCTION.
STORM WATER MAINTENANCE NOTE:
THE PURPOSE OF THIS PROJECT IS TO REHABILITATE THE EXISTING SEWER MAIN. ALL AREAS DISTURBED WILL BE RETURNED TO EXACTLY THE SAME CONDITION THAT EXISTED PRIOR TO THE WORK COMPLETED.
THERE IS NO INCREASE IN FLOW OR CHANGE IN THE RUN-OFF CHARACTERISTICS FROM EXISTING
CONDITIONS.
SPECIAL NOTE:
NO LAND SURVEY WAS DONE ON REHABILITATION DESIGN. ALL THE INFORMATION SHOWN ON PLAN & PROFILE SHEETS IS TAKEN FROM EXISTING WSSC RECORDS. DISTANCES, PIPE SIZES AND PIPE TYPES ARE APPROXIMATE AND MAY NOT REFLECT CHANGES OR ALTERATIONS MADE IN THE FIELD. INFORMATION
PROVIDED HERE IS FOR PLANNING PURPOSES ONLY.
EXISTING UTILITIES AND STORM DRAINS SHOWN ON THIS DRAWING ARE FROM GIS INFORMATION AND CANNOT BE RELIED ON FOR ACCURACY. THE UTILITIES HAVE NOT BEEN DESIGNATED OR TEST PITTED;
THEREFORE, SOME UTILITIES MAY NOT BE SHOWN ON THE DRAWINGS. EXISTING UTILITY CROSSINGS ARE NOT SHOWN ON THE PROFILES. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES INCLUDING
UTILITY CROSSINGS PRIOR TO BEGINNING WORK IN THE SEWER SEGMENT AREA.
TRAFFIC CONTROL NOTE:
ALL LANE CLOSURES/TRAFFIC CONTROLS ON MDSHA ROAD(S) SHALL COMPLY WITH MDSHA CODES AND STANDARDS. LANE CLOSURE PERMIT SHALL BE APPLIED AT LEAST TWO WORKING DAYS (48 HOURS) PRIOR
TO CLOSURE. THE PERMIT MUST BE APPROVED BEFORE STARTING WORK.
GENERAL NOTES:
1. ALL 8-INCH, 10-INCH AND 12-INCH SEWER PIPE SHALL BE SDR 35 P.V.C. IF DEPTH IS
LESS THAN 10' AND SDR 26 PVC IF DEPTH IS GREATER THAN 10', UNLESS SHOWN
OTHERWISE.
2. ALL SHC'S TO BE 4-INCH SDR 35 PVC IF DEPTH IS LESS THEN 10', AND SDR 26 PVC IF
DEPTH GREATER THAN 10', UNLESS SHOWN OTHERWISE. 2% MINIMUM SLOPE. EACH
RELAYED SHC SHALL TERMINATE WITH A CLEANOUT AT THE PROPERTY LINE. DO
NOT RELAY PREVIOUSLY ABANDONED/CAPPED SHC. REPLACE EXISTING SHC
CONNECTED TO EXISTING UPSTREAM AND DOWNSTREAM MANHOLES AS DIRECTED
BY FIELD ENGINEER IN ACCORDANCE WITH ALL APPLICABLE STANDARD DETAILS.
MAINTAIN 2% SLOPE UNLESS OTHERWISE SHOWN. EACH 6-INCH DIAMETER DOUBLE
SEWER HOUSE CONNECTION IS TO BE RELAYED AS A SINGLE 4-INCH DIAMETER OR
6-INCH DIAMETER SEWER HOUSE CONNECTION, AS INDICATED ON DRAWING.
3. FOR (DHC) DROP HOUSE CONNECTION SHOWN ON PLAN AND PROFILE, SEE
STANDARD DETAIL S/6.1.
4. APPROVAL BY SEDIMENT CONTROL INSPECTOR IS REQUIRED UPON COMPLETION
OF INSTALLATION OF PERIMETER EROSION AND SEDIMENT CONTROLS BEFORE
PROCEEDING WITH ANY OTHER LAND DISTURBANCE, GRADING, OR
CONSTRUCTION.
5. FOR DETAILS OF SEDIMENT CONTROL DEVICES TO BE INSTALLED BY CONTRACTOR,
SEE DWG S.C. 1
6. REPLACEMENT SEWER SHALL BE RELAYED IN THE SAME LOCATION AT THE SAME
LINE AND GRADE AS THE EXISTING SEWER, UNLESS OTHERWISE NOTED ON THE
DRAWINGS.
7. CONTRACTOR SHALL MAINTAIN FLOW THROUGH EXISTING GRAVITY AND PRESSURE
SEWER UNTIL NEW SEWER MAIN IS CONSTRUCTED AND PLACE IN SERVICE.
8. WSSC'S INSPECTOR SHALL BE PRESENT FOR THE OPERATION OF ANY WSSC
VALVE.
9. THE CONTRACTOR SHALL CONTACT PIPELINE CONSTRUCTION DIVISION AT
301-206-7339, AT LEAST TWO WEEKS PRIOR TO THE START OF CONSTRUCTION TO
ARRANGE FOR A PRE-CONSTRUCTION MEETING.
10. NOTIFY WSSC'S PIPELINE CONSTRUCTION DIVISION AT 301-206-7339 AT LEAST 72
HOURS PRIOR TO THE START OF CONSTRUCTION. INSPECTION OF MATERIALS
REQUIRED FOR THE PROJECT SHALL TAKE PLACE AT THE CONSTRUCTION SITE.
11. CONTRACTOR TO PROVIDE TEMPORARY WATER AND/OR SEWER SERVICE DURING
CONSTRUCTION.
12. CONTRACTOR IS TO MAINTAIN EXISTING WATER AND/OR SEWER SERVICE TO
EXISTING PROPERTY AT ALL TIMES, RECONNECT AS NECESSARY.
13. CONTRACTOR TO PROVIDE SEDIMENT CONTROL FOR STOCKPILE AREAS.
14. THE CONTRACTOR SHALL TEST PIT AND DETERMINE THE LOCATION, ELEVATION,
SIZE, MATERIAL, PIPE DIAMETER, AND OUT OF ROUNDNESS OF THE EXISTING PIPE
WHERE THE NEW PIPING WILL CONNECT, PRIOR TO ORDERING ANY NEW MATERIAL.
UPON DELIVERY OF REQUIRED MATERIALS AND PRIOR TO THE REMOVAL OF
EXISTING PIPING, THE CONTRACTOR SHALL CONFIRM THAT ALL MATERIALS FITS
TOGETHER.
15. EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN WERE TAKEN FROM
UTILITY COMPANY DOCUMENTS. THE CONTRACTOR SHOULD NOTIFY MISS UTILITY
AT 1-800-257-7777, 48 HRS IN ADVANCE OF COMMENCING THIS WORK, SO
APPROPRIATE MARKING OF UTILITIES CAN BE MADE.
16. EXISTING PAVEMENT TO BE SWEPT AT THE END OF EACH BUSINESS DAY.
17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING STAGING AREA(S) AND
MOBILIZATION TO AND FROM SUCH AREA AT NO COST TO WSSC.
18. ALL MATERIALS REQUIRED UNDER THIS CONTRACT SHALL BE FURNISHED BY THE
CONTRACTOR AT NO EXPENSE TO WSSC IN ACCORDANCE WITH THE LATEST
EDITION OF THE WSSC GENERAL CONDITIONS AND STANDARD SPECIFICATIONS.
19. UPON COMPLETION OF CONSTRUCTION THE CONTRACTOR SHALL PREPARE
AS-BUILT PLANS AND SUBMIT TO PIPELINE CONSTRUCTION DIVISION CONTRACT
MANAGER.
20. CONTRACTOR SHALL PERFORM COMPACTION TESTING FOLLOWING ASTM D1566,
ASTM D6938, OR ASTM D2937 AT MINIMUM RATE OF 1 TEST EVERY 100 FEET OF FILL
ALONG MAIN TRENCH AND AT EVERY LATERAL TRENCH, STRUCTURE AND VALVE
BOX IN TYPE 1 AREAS.
21. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE AND/OR REPLACEMENT
REQUIRED AS A RESULT OF ANY WORK WITH OR NEAR THE EXISTING WSSC MAINS
AT THE CONTRACTOR'S EXPENSE.
22. WSSC TAKES NO RESPONSIBILITY FOR THE ACCURACY OF "AS-BUILT" INFORMATION
PROVIDED BY WSSC OR ANY DEVIATIONS FROM DESIGN PLANS OF EXISTING
PIPELINES. THE DESIGNER MAY USE THIS INFORMATION AS THEY DESIRE BUT IS
RESPONSIBLE FOR DETERMINING IF ANY CHANGES HAVE BEEN MADE TO THE
ORIGINAL DESIGN OF THE EXISTING PIPELINE, PERFORMING TEST PITS AND FIELD
SURVEYS TO VERIFY IF THEY PLAN TO UTILIZE THIS INFORMATION, AND FOR
ADJUSTING THEIR DESIGN ACCORDINGLY. WSSC DOES NOT PROVIDE ANY
WARRANTY OR ANY ASSURANCES THAT ANY INFORMATION PROVIDED IS
ACCURATE AND/OR UP TO DATE.
23. WSSC TAKES NO RESPONSIBILITY FOR DESIGN ERRORS AND/OR OMISSIONS.
WSSC'S APPROVAL/PERMIT ACCEPTANCE DOES NOT CONSTITUTE A WARRANTY
NOR DOES IT RELEASE THE CONTRACTOR FROM RESPONSIBILITY FOR ANY
DEFICIENCY WHICH MAY SUBSEQUENTLY BE FOUND.
24. ALL NEW REPLACEMENT SEWERS SHALL MATCH THE EXISTING INVERT ELEVATION.
25. CONTRACTOR SHALL NOT INSTALL LATERAL CONNECTIONS TO NEW MANHOLE
UNLESS THERE IS NO ALTERNATIVE. CONTRACTOR SHALL USE RUBBER BOOT IF
THE LATERAL CONNECTION IS TO BE MADE TO NEW MANHOLE.
26. WORK SHALL COMPLY WITH THE CURRENT COUNTY SPECIFICATIONS FOR UTILITY
CONSTRUCTION PERMIT AND/OR MDSHA UTILITY PERMIT. COMPLETE REPAIR
(RESTORATION OF RIGHT OF WAY) SHALL BE MADE OF ANY AND ALL DAMAGES
DONE TO THE EXISTING IMPROVEMENTS IN THE PUBLIC RIGHT OF WAY CAUSED BY
CONSTRUCTION OPERATIONS ON THE SITE. ALL LANE CLOSURES/TRAFFIC
CONTROLS ON COUNTY ROAD(S) SHALL COMPLY WITH APPROVED TRAFFIC
CONTROL PLANS, WORK ZONE TEMPORARY TRAFFIC CONTROL STANDARDS AND
DIRECTIONS OF THE PERMITTING AUTHORITY INSPECTOR.
27. USE DIP, RCP, OR AWWA C900/905 PVC PIPE WHEN CONNECTING TO AN EXISTING
BRICK MANHOLE. SEE STANDARD DETAIL S/3.0.
TREE PROTECTION:
1. PROVIDE TREE PROTECTION FOR TREES AS DIRECTED BY WSSC ENVIRONMENTAL PROGRAMS UNIT., SEE
STANDARD DETAILS SC/17.0 & 18.0
2. CONTRACTOR SHALL NOT STOCKPILE MATERIALS OR EQUIPMENTS UNDER THE DRIPLINE OF ANY TREES.
3. CONTACT WSSC URBAN FORESTER AT (301) 206-8074 FOR TREE ISSUES NOT COVERED BY MARYLAND
ROADSIDE TREE PERMIT.
PAVEMENT RESTORATION:
MILL AND OVERLAY WILL BE DONE UNDER A SEPARATE WSSC PAVING CONTRACT AND IS NOT INCLUDED IN
THIS CTO.
NAME: THE WILSON T. BALLARD COMPANY
ADDRESS: 17 GWYNNS MILL COURT, OWINGS MILLS, MD 21117
PHONE: (410) 363-0150
CONTACT : SHAWN BURNETT
EMAIL: SBURNETT@WTBCO.COM
WASHINGTON SUBURBAN SANITARY COMMISSION
1 1 COVER
SC-1 SC-1 E+S DETAILS
1 thru 6
SC-1 SEDIMENT CONTROL DETAILS
N A
D
3/
N G
V D
S C
A
LE
: 1
0'
PA
TH
Pa re nt
\T
-D riv e\ W
SS
C
\P M
A1
O pt io n
Ye ar
\8
-1
.0 8_
Pa in t B ra nc h
Ba si n\ D
W G s\
G -0
P4 .d w g
MG Co. PAGE 5167 GRIDS B09, B10, C09, C10
WSSC Erosion and Sediment Control Approval Note:
This plan has been approved per requirements in the:
Standard Procedures of the WSSC Regulations for Utility Erosion and Sediment Control, Section V. Paragraph A.
Reviewed by: __________________________________________
SEDIMENT CONTROL NOTES:
1. CONTACT WSSC ENVIRONMENTAL PROGRAMS SECTION AT (301) 206-8077, 48 HOURS PRIOR
TO STARTING ANY UTILITY WORK UNDER THIS CONTRACT.
2. ANY GROUND WATER OR SURFACE WATER PUMPED DURING THIS PROJECT SHOULD BE
DISCHARGED THROUGH AN APPROVED DE-WATERING DEVICE. SEE STANDARD DETAIL
SC/15.0, SC/15.1.
3. STREETS AND PAVED WALKWAYS SHALL BE BROOM SWEPT DAILY.
4. INSTALL CURB INLET OR AT-GRADE INLET PROTECTION AS NEEDED OR AS DIRECTED BY WSSC
ENVIRONMENTAL STAFF. SEE STANDARD DETAIL SC/16.0, SC/16.1.
5. PLACE SILT FENCE PER STANDARD DETAIL SC/1.0 ALONG LOW SIDE OF EXCAVATED AREA
WHEN WORKING IN NON-PAVED AREAS OR AS SHOWN ON PLANS, OR AS DIRECTED BY WSSC
ENVIRONMENTAL STAFF IN THE FIELD. CONTRACTOR SHALL PROVIDE DAILY TEMPORARY
STABILIZATION FOR ALL DISTURBED NON-PAVED AREAS.
6. ANY EXCAVATED OR STOCKPILED MATERIAL LEFT OVERNIGHT SHALL BE COVERED WITH AN
IMPERMEABLE MATERIAL. PROVIDE SEDIMENT CONTROL FOR ALL OFFSITE
STAGING/STOCKPILE AREAS.
7. WHEN WORKING IN PAVED SURFACES, PLACE EXCAVATED MATERIAL ON HIGH SIDE OF
TRENCH.
8. ANY SLURRY GENERATED BY PAVEMENT SAW CUTTING SHALL BE CONTAINED BY THE
CONTRACTOR TO PREVENT SLURRY FROM ENTERING THE EXISTING STORM DRAIN SYSTEM OR
WATERWAY BY USING APPROVED METHODS, DEVICES, OR AS DIRECTED BY THE WSSC
ENVIRONMENTAL STAFF. CONTRACTOR SHALL PROPERLY REMOVE AND DISPOSE OF
CONTAINED SLURRY AT THE END OF EACH WORK DAY.
9. FOR AREAS WITHIN LIMIT OF DISTURBANCE WHICH DO NOT DRAIN TO AN APPROVED
EROSION AND SEDIMENT CONTROL MEASURE AND/OR WHERE THE INSTALLATION OF
CONTROLS IS NOT FEASIBLE (ROADWAY, SIDEWALK, ETC.) CONTRACTOR SHALL ONLY DISTURB
AREA WHICH CAN BE COMPLETED AND STABILIZED BY THE END OF EACH WORKING DAY.
STABILIZATION SHALL BE AS FOLLOWS:
A. FOR AREAS TO BE PAVED: STONE BASE SHALL BE APPLIED.
B. FOR AREAS TO BE VEGETATIVELY STABILIZED:
I. PERMANENT SEED AND SOIL STABILIZATION MATTING FOR SOD FOR ALL STEEP SLOPES, CHANNELS, OR
SWALES.
II. PERMANENT SEED AND MULCH FOR ALL OTHER AREAS. ANY AREAS WHICH CAN NOT BE STABILIZED BY THE END OF
EACH WORKING DAY MUST HAVE SILT FENCE SC/1.0 INSTALLED ON THE DOWN SLOPE SIDE.
JOB NUMBER
CRLRMH7338T22
RELAY DRAWINGS
PROFESSIONAL CERTIFICATION
I HEREBY CERTIFY THAT THESE
DOCUMENTS WERE PREPARED OR
APPROVED BY ME, AND THAT I AM A
DULY LICENSED PROFESSIONAL
ENGINEER UNDER THE LAWS OF THE
STATE OF MARYLAND.
NAME: OMAR MUHAMMAD
LICENSE NO.: 45882
EXP. DATE: 9/30/2024
WORK IN THE VICINITY OF ASBESTOS-CEMENT PIPE
THE CONTRACTOR SHALL REFER TO AWWA M16
"WORK PRACTICES FOR ASBESTOS-CEMENT PIPE"
FOR PRECAUTIONS CUTTING AND HANDLING
ASBESTOS-CEMENT PIPE.
CRLRMH7338T22 SEGMENTS
SEWER MANHOLE
LEGEND
RELAY DRAWINGS2-6 2-6
TOTAL AREA TO BE DISTURBED:
0.61 ACRES
26,721 SQ. FT.
Docusign Envelope ID: E7490073-8D7E-4834-B3F8-F0E87B373330
09/10/2024
Docusign Envelope ID: C0BB6F87-19AB-4FD1-82BC-2A8297E89356
Oct 9, 2024 | 6:44 AM EDT
Oct 11, 2024 | 1:24 PM EDT
Date: _________________ Plan No.: _______________________CRLRMH7338T22
REVISED TITLE BLOCK, TASK ORDER NO.,
JOB NUMBER, AND PAGE NUMBER.
9/9/2025
GWALLAC
Revision
GWALLAC
Revision
GWALLAC
Revision
GWALLAC
Revision
GWALLAC
Revision
GWALLAC
Revision
GWALLAC
Revision
GWALLAC
Revision
009M
010N
024M
ALLERTON LANE
BR
O
AD
M
O R
E R O
AD
12915
02028025S
12917
12928
ALLERTON
LANE
12926
12924
12925
12927
12914
BROADMORE
ROAD
12912
12921
12913
12911
12909
025K
02028010S
02028024S
SEWER REHABILITATION MANHOLES REHABILITATION
Asset ID Diameter Length Description Asset ID Depth Diameter Description
02028025S 8" 126' REPLACE MAINLINE SEWER (UPSIZE FROM 6" TO 8"),
RENEW LATERALS & INSTALL CLEANOUTS
02028025K 9.8' N/A REPLACE EX. LAMPHOLE WITH NEW MANHOLE
MATERIALS LIST
ITEM UNIT QTY
8" PVC SEWER MAIN LF 126
4" PVC LATERAL LF 151
8"X4" TEE EA 3
4" CLEANOUT EA 5
48" DIA. PRECAST MANHOLE VF 9.8
CCTV INFORMATION HOUSE CONNECTION CARD
PROPERTY
ADDRESS
BILLING
ADDRESS
REFERENCE
MH
CAMERA
DIRECTION
CCTV
FOOTAGE
TO HC
CCTV
POSITION
OF HC
EXISTING
SHC SIZE
EXISTING
SHC
MATERIAL
EXISTING
CLEANOUT
SHC
TYPE
LENGTH OF
EXISTING SHC
TREE
IMPACTS REMARKS
(US/DS) (LINEAR
FEET) (CLOCK) INCHES (YES/NO) (SINGLE/
DOUBLE) (LINEAR FEET) (COUNT-DBH)
12912 Broadmore Rd
12912 Broadmore Rd N/A N/A N/A N/A 4 Asbestos
Cement Yes Single 38 No Excavated Renewal of Lateral & Install Cleanout
12911 Broadmore Rd
12911 Broadmore Rd N/A N/A N/A N/A 4 Asbestos
Cement Yes Single 28 No Excavated Renewal of Lateral & Install Cleanout
12913 Broadmore Rd
12913 Broadmore Rd N/A N/A N/A N/A 4 Asbestos
Cement Yes Single 24 No Excavated Renewal of Lateral & Install Cleanout
12914 Broadmore Rd
12914 Broadmore Rd In 02028024M N/A N/A N/A 4 Asbestos
Cement Yes Single 36 No Excavated Renewal of Lateral & Install Cleanout
12915 Broadmore Rd
12915 Broadmore Rd In 02028024M N/A N/A N/A 4 Asbestos
Cement Yes Single 25 No Excavated Renewal of Lateral & Install Cleanout
Sewer 02028025S
REPLACE MAINLINE SEWER (UPSIZE FROM 6" TO 8"),
RENEW LATERALS & INSTALL CLEANOUTS
12911 BROADMORE ROAD
PAINT BRANCH BASIN
217NE01
P5167B09
217NE01
BROADMORE ROAD
WSSC CONTRACT: 62-1203
025K024M
NOT TO SCALE
NOTES:
1. Prior to excavation, contractor shall locate all utilities per Miss Utility (800) 257-7777.
2. All work shall be in accordance with the WSSC specification and contract documents.
3. Call WSSC Environmental at 301-206-2075 for tree removal and pruning.
4. Existing utilities and storm drains shown on this drawing are from GIS information and cannot be relied on for accuracy. The utilities have not been designated or test pitted. Contractor shall contact Miss Utility to have all existing utilities located.
ADC MAP
WSSC 200'S
JOB NO.
LEGEND
CRLRMH7338T22
ENGINEER:
NO
200'S
DATE
DATE REVISIONS
THESE DOCUMENTS CONTAIN
PRIVILEGED AND CONFIDENTIAL
INFORMATION WHICH SHALL NOT
BE REDISTRIBUTED WITHOUT
PRIOR WSSC APPROVAL
WSSC PIPELINE DESIGN DIVISION
PDD PROJECT MANAGER
JOB NUMBER
CRLRMH7338T22
TASK ORDER NO.212
SANITARY SEWER REHABILITATION (SSR) MDE FUNDED PROJECT
PAINT BRANCH BASIN
SEWER INFRASTRUCTURE SECTION
WASHINGTON SUBURBAN SANITARY COMMISSION NAME: THE WILSON T. BALLARD COMPANY
ADDRESS: 17 GWYNNS MILL COURT, OWINGS MILLS, MD 21117
PHONE: (410) 363-0150
CONTACT : SHAWN BURNETT
EMAIL: SBURNETT@WTBCO.COM
5/24/2024 2:41 PM - PLOT DATE
PA
TH
T:
\W
SS
C \P
M
A1
O pt io n Ye ar \8
-1
.0
8_ Pa in t B ra nc h Ba si n\
D W
G s\
C
-1
.d w g
POINT/SPOT REPAIR
SUBJECT SEWERS
SUBJECT MANHOLES
EXISTING MANHOLES
EXISTING SEWERS
WATER MAIN
EXISTING GAS
EXISTING STORM DRAIN
EXISTING TREE
EXISTING UTILITY POLE
CONCRETE CURB AND GUTTER
(TO BE REPLACED FROM JOINT TO JOINT)
Docusign Envelope ID: E7490073-8D7E-4834-B3F8-F0E87B373330Docusign Envelope ID: C0BB6F87-19AB-4FD1-82BC-2A8297E89356
Oct 8, 2024 | 11:13 AM EDT
OF 6
GWALLAC
Revision
GWALLAC
Revision
GWALLAC
Revision
M
ORNINGSIDE DRIVE
E RANDO
LPH RO
AD
SMITH VILLAGE ROAD
1101 SMITH
VILLAGE ROAD
MORNINGSIDE
DRIVE
110913001
JE
W
EL COURT
078N
031N
030M
02028031S
02029083S
02028030S
082M 02029082S
02030078S
X
REMOVE 5' HT.
VARIEGATED
SHRUB AS
NEEDED
SEWER REHABILITATION MANHOLES REHABILITATION
Asset ID Ex.
Diameter
Prop.
Diameter
Length Description Asset ID Depth Diameter Description
02028031S 6" 8" 214' REPLACE MAINLINE SEWER (UPSIZE FROM 6" TO 8"),
RENEW LATERALS & INSTALL CLEANOUTS
02028030M 10.9' 48" REPLACE FRAME AND COVER
02028031N UNK 48" LOCATE AND ADJUST MH, REPLACE FRAME AND
COVER
MATERIALS LIST
ITEM UNIT QTY
8" PVC SEWER MAIN LF 214
4" PVC LATERAL LF 110
8"X4" WYE EA 4
4" CLEANOUT EA 4
CCTV INFORMATION HOUSE CONNECTION CARD
PROPERTY
ADDRESS
BILLING
ADDRESS
REFERENCE
MH
CAMERA
DIRECTION
CCTV
FOOTAGE
TO HC
CCTV
POSITION
OF HC
EXISTING
SHC SIZE
EXISTING
SHC
MATERIAL
EXISTING
CLEANOUT
SHC
TYPE
LENGTH OF
EXISTING SHC
TREE
IMPACTS REMARKS
(US/DS) (LINEAR
FEET) (CLOCK) INCHES (YES/NO) (SINGLE/
DOUBLE) (LINEAR FEET) (COUNT-DBH)
1231 E Randolph Rd
1231 E Randolph Rd 02028030M US 32 3 4 Asbestos
Cement Yes Single 10 No Excavated Renewal of Lateral & Install Cleanout
1101 Smith Village Rd
1101 Smith Village Rd 02028030M US 83 9 4
Assume Asbestos Cement
Yes Single 40 No Excavated Renewal of Lateral & Install Cleanout
1233 E Randolph Rd
1233 E Randolph Rd 02028030M US 85 3 4 Asbestos
Cement Yes Single 20 No Excavated Renewal of Lateral & Install Cleanout
1103 Morningside Dr
1103 Morningside Dr 02028030M US 186 9 4
Assume Asbestos Cement
Yes Single 40 No Excavated Renewal of Lateral & Install Cleanout
Sewer 02028031S
REPLACE MAINLINE SEWER (UPSIZE FROM 6" TO 8"),
RENEW LATERALS & INSTALL CLEANOUTS
1233 E RANDOLPH ROAD
PAINT BRANCH BASIN
217NE02
P5167C09
217NE02
E. RANDOLPH ROAD
WSSC CONTRACT: 65-4044
031N030M
402.68 404.59
392.21 392.35 394.52
0+
2+
NOT TO SCALE
NOTES:
1. Prior to excavation, contractor shall locate all utilities per Miss Utility (800) 257-7777.
2. All work shall be in accordance with the WSSC specification and contract documents.
3. Call WSSC Environmental at 301-206-2075 for tree removal and pruning.
4. Existing utilities and storm drains shown on this drawing are from GIS information and cannot be relied on for accuracy. The utilities have not been designated or test pitted. Contractor shall contact Miss Utility to have all existing utilities located.
ADC MAP
WSSC 200'S
JOB NO.
LEGEND
CRLRMH7338T22
ENGINEER:
NO
200'S
DATE
DATE REVISIONS
THESE DOCUMENTS CONTAIN
PRIVILEGED AND CONFIDENTIAL
INFORMATION WHICH SHALL NOT
BE REDISTRIBUTED WITHOUT
PRIOR WSSC APPROVAL
WSSC PIPELINE DESIGN DIVISION
PDD PROJECT MANAGER
JOB NUMBER
CRLRMH7338T22
TASK ORDER NO. 212
SANITARY SEWER REHABILITATION (SSR) MDE FUNDED PROJECT
PAINT BRANCH BASIN
SEWER INFRASTRUCTURE SECTION
WASHINGTON SUBURBAN SANITARY COMMISSION NAME: THE WILSON T. BALLARD COMPANY
ADDRESS: 17 GWYNNS MILL COURT, OWINGS MILLS, MD 21117
PHONE: (410) 363-0150
CONTACT : SHAWN BURNETT
EMAIL: SBURNETT@WTBCO.COM
5/24/2024 2:42 PM - PLOT DATE
PA
TH
T:
\W
SS
C \P
M
A1
O pt io n Ye ar \8
-1
.0
8_ Pa in t B ra nc h Ba si n\
D W
G s\
C
-1
.d w g
POINT/SPOT REPAIR
SUBJECT SEWERS
SUBJECT MANHOLES
EXISTING MANHOLES
EXISTING SEWERS
WATER MAIN
EXISTING GAS
EXISTING STORM DRAIN
EXISTING TREE
EXISTING UTILITY POLE
CONCRETE CURB AND GUTTER
(TO BE REPLACED FROM JOINT TO JOINT)
Docusign Envelope ID: E7490073-8D7E-4834-B3F8-F0E87B373330Docusign Envelope ID: C0BB6F87-19AB-4FD1-82BC-2A8297E89356
Oct 8, 2024 | 11:13 AM EDT
OF 6
GWALLAC
Revision
GWALLAC
Revision
GWALLAC
Revision
036N
BR
O
AD
M
O R
E R O
AD
12909
035M
BROADMORE PLACE
KILGORE ROAD
02029036S
006N
005M
12907
12905
12903
12901
12823
12912
12910
BROADMORE
PLACE
BROADMORE
PLACE
BROADMORE
PLACE
BROADMORE
PLACE
BROADMORE
PLACE
12906
12900
12906
KILGORE
ROAD
12904
KILGORE
ROAD
ABANDONED TAP
02028005S
02028006S
02029035S
SEWER REHABILITATION MANHOLES REHABILITATION
Asset ID Ex.
Diameter
Prop.
Diameter
Length Description Asset ID Depth Diameter Description
02029036S 6" 8" 303' REPLACE MAINLINE SEWER (UPSIZE FROM 6" TO 8"),
RENEW LATERALS & INSTALL CLEANOUTS
02029035M 9.3' 48" CEMENTITIOUS LINING
MATERIALS LIST
ITEM UNIT QTY
8" PVC SEWER MAIN LF 303
4" PVC LATERAL LF 215
8"X4" TEE EA 5
4" CLEANOUT EA 8
CCTV INFORMATION HOUSE CONNECTION CARD
PROPERTY
ADDRESS
BILLING
ADDRESS
REFERENCE
MH
CAMERA
DIRECTION
CCTV
FOOTAGE
TO HC
CCTV
POSITION
OF HC
EXISTING
SHC SIZE
EXISTING
SHC
MATERIAL
EXISTING
CLEANOUT
SHC
TYPE
LENGTH OF
EXISTING SHC
TREE
IMPACTS REMARKS
(US/DS) (LINEAR
FEET) (CLOCK) INCHES (YES/NO) (SINGLE/
DOUBLE) (LINEAR FEET) (COUNT-DBH)
12901 Broadmore Rd
12901 Broadmore Rd In 02029035M N/A N/A N/A 4 Asbestos
Cement Yes Single 18 No Excavated Renewal of Lateral & Install Cleanout
12900 Broadmore Rd
12900 Broadmore Rd 02029035M US 50 9 4 Asbestos
Cement Yes Single 39 No Excavated Renewal of Lateral & Install Cleanout
12903 Broadmore Rd
12903 Broadmore Rd 02029035M US 86 3 4 Asbestos
Cement Yes Single 19 No Excavated Renewal of Lateral & Install Cleanout
12905 Broadmore Rd
12905 Broadmore Rd 02029035M US 155 3 4 Asbestos
Cement Yes Single 19 No Excavated Renewal of Lateral & Install Cleanout
12906 Broadmore Rd
12906 Broadmore Rd 02029035M US 159 9 4 Asbestos
Cement Yes Single 39 No Excavated Renewal of Lateral & Install Cleanout
12907 Broadmore Rd
12907 Broadmore Rd 02029035M US 227 3 4 Asbestos
Cement Yes Single 19 No Excavated Renewal of Lateral & Install Cleanout
12909 Broadmore Rd
12909 Broadmore Rd In 02029036N N/A N/A N/A 4 Asbestos
Cement Yes Single 22 No Excavated Renewal of Lateral & Install Cleanout
12910 Broadmore Rd
12910 Broadmore Rd In 02029036N N/A N/A N/A 4 Asbestos
Cement Yes Single 40 No Excavated Renewal of Lateral & Install Cleanout
Sewer 02029036S
REPLACE MAINLINE SEWER (UPSIZE FROM 6" TO 8"),
RENEW LATERALS & INSTALL CLEANOUTS
12906 BROADMORE ROAD
PAINT BRANCH BASIN
217NE01
P5167B09
217NE01
BROADMORE ROAD
WSSC CONTRACT: 62-5713
035M
036N
NOT TO SCALE
NOTES:
1. Prior to excavation, contractor shall locate all utilities per Miss Utility (800) 257-7777.
2. All work shall be in accordance with the WSSC specification and contract documents.
3. Call WSSC Environmental at 301-206-2075 for tree removal and pruning.
4. Existing utilities and storm drains shown on this drawing are from GIS information and cannot be relied on for accuracy. The utilities have not been designated or test pitted. Contractor shall contact Miss Utility to have all existing utilities located.
ADC MAP
WSSC 200'S
JOB NO.
LEGEND
CRLRMH7338T22
ENGINEER:
NO
200'S
DATE
DATE REVISIONS
THESE DOCUMENTS CONTAIN
PRIVILEGED AND CONFIDENTIAL
INFORMATION WHICH SHALL NOT
BE REDISTRIBUTED WITHOUT
PRIOR WSSC APPROVAL
WSSC PIPELINE DESIGN DIVISION
PDD PROJECT MANAGER
JOB NUMBER
CRLRMH7338T22
TASK ORDER NO. 212
SANITARY SEWER REHABILITATION (SSR) MDE FUNDED PROJECT
PAINT BRANCH BASIN
SEWER INFRASTRUCTURE SECTION
WASHINGTON SUBURBAN SANITARY COMMISSION NAME: THE WILSON T. BALLARD COMPANY
ADDRESS: 17 GWYNNS MILL COURT, OWINGS MILLS, MD 21117
PHONE: (410) 363-0150
CONTACT : SHAWN BURNETT
EMAIL: SBURNETT@WTBCO.COM
5/24/2024 2:45 PM - PLOT DATE
PA
TH
T:
\W
SS
C \P
M
A1
O pt io n Ye ar \8
-1
.0
8_ Pa in t B ra nc h Ba si n\
D W
G s\
C
-1
.d w g
POINT/SPOT REPAIR
SUBJECT SEWERS
SUBJECT MANHOLES
EXISTING MANHOLES
EXISTING SEWERS
WATER MAIN
EXISTING GAS
EXISTING STORM DRAIN
EXISTING TREE
EXISTING UTILITY POLE
CONCRETE CURB AND GUTTER
(TO BE REPLACED FROM JOINT TO JOINT)
Docusign Envelope ID: E7490073-8D7E-4834-B3F8-F0E87B373330Docusign Envelope ID: C0BB6F87-19AB-4FD1-82BC-2A8297E89356
Oct 8, 2024 | 11:13 AM EDT
OF 6
GWALLAC
Revision
GWALLAC
Revision
GWALLAC
Revision
M
ORNINGSIDE DRIVE
E RANDOLPH ROAD
13001
JE
W
EL
COURT
031N
044M
043M
077M
082M
083M
084N
02029080S
13005
13009
13013
13004
13008
02030078S
02030077S
02029082S
S
02029083S
02029043S
02029044S
SEWER REHABILITATION MANHOLES REHABILITATION
Asset ID Ex.
Diameter
Prop.
Diameter
Length Description Asset ID Depth Diameter Description
02029044S 6" 8" 125' REPLACE MAINLINE SEWER (UPSIZE FROM 6" TO 8"), RENEW
LATERALS & INSTALL CLEANOUTS
02029044M 10.5' 48" CEMENTITIOUS LINING
02029080S 6" 8" 155' 02029043M 14.9' 48" CEMENTITIOUS LINING
MATERIALS LIST
ITEM UNIT QTY
8" PVC SEWER MAIN LF 280
4" PVC LATERAL LF 59
8"X4" TEE EA 3
4" CLEANOUT EA 4
CCTV INFORMATION HOUSE CONNECTION CARD
PROPERTY
ADDRESS
BILLING
ADDRESS
REFERENCE
MH
CAMERA
DIRECTION
CCTV
FOOTAGE
TO HC
CCTV
POSITION
OF HC
EXISTING
SHC SIZE
EXISTING
SHC
MATERIAL
EXISTING
CLEANOUT
SHC
TYPE
LENGTH OF
EXISTING SHC
TREE
IMPACTS REMARKS
(US/DS) (LINEAR
FEET) (CLOCK) INCHES (YES/NO) (SINGLE/
DOUBLE) (LINEAR FEET) (COUNT-DBH)
1239 E Randolph Rd
1239 E Randolph Rd In 02029044M N/A N/A N/A 4 Assume CI Yes Single 14 No Excavated Renewal of Lateral & Install
Cleanout
1241 E Randolph Rd
1241 E Randolph Rd 02029044M DS 23 3 4 PVC Yes Single 14 No Reconnect
1243 E Randolph Rd
1243 E Randolph Rd 02029044M DS 129 3 4 CI Yes Single 15 No Excavated Renewal of Lateral & Install
Cleanout
1245 E Randolph Rd
1245 E Randolph Rd 02029044M DS 129 3 4 CI Yes Single 15 No Excavated Renewal of Lateral & Install
Cleanout
1251 E Randolph Rd
1251 E Randolph Rd
In 02029043M N/A N/A N/A 4 CI Yes Single 15 No Excavated Renewal of Lateral & Install
Cleanout
Sewer 02029044S/02029080S
REPLACE MAINLINE SEWER (UPSIZE FROM 6" TO 8"),
RENEW LATERALS & INSTALL CLEANOUTS
1239 E RANDOLPH ROAD
PAINT BRANCH BASIN
217NE02
P5167C10
217NE02
E RANDOLPH ROAD
WSSC CONTRACT: 66-2428A
080T 044M
E RANDOLPH ROAD
WSSC CONTRACT: 63-1580
043M
080T
NOT TO SCALE
NOTES:
1. Prior to excavation, contractor shall locate all utilities per Miss Utility (800) 257-7777.
2. All work shall be in accordance with the WSSC specification and contract documents.
3. Call WSSC Environmental at 301-206-2075 for tree removal and pruning.
4. Existing utilities and storm drains shown on this drawing are from GIS information and cannot be relied on for accuracy. The utilities have not been designated or test pitted. Contractor shall contact Miss Utility to have all existing utilities located.
ADC MAP
WSSC 200'S
JOB NO.
LEGEND
CRLRMH7338T22
ENGINEER:
NO
200'S
DATE
DATE REVISIONS
THESE DOCUMENTS CONTAIN
PRIVILEGED AND CONFIDENTIAL
INFORMATION WHICH SHALL NOT
BE REDISTRIBUTED WITHOUT
PRIOR WSSC APPROVAL
WSSC PIPELINE DESIGN DIVISION
PDD PROJECT MANAGER
JOB NUMBER
CRLRMH7338T22
TASK ORDER NO. 212
SANITARY SEWER REHABILITATION (SSR) MDE FUNDED PROJECT
PAINT BRANCH BASIN
SEWER INFRASTRUCTURE SECTION
WASHINGTON SUBURBAN SANITARY COMMISSION NAME: THE WILSON T. BALLARD COMPANY
ADDRESS: 17 GWYNNS MILL COURT, OWINGS MILLS, MD 21117
PHONE: (410) 363-0150
CONTACT : SHAWN BURNETT
EMAIL: SBURNETT@WTBCO.COM
5/28/2024 10:58 AM - PLOT DATE
PA
TH
T:
\W
SS
C \P
M
A1
O pt io n Ye ar \8
-1
.0
8_ Pa in t B ra nc h Ba si n\
D W
G s\
C
-1
.d w g
POINT/SPOT REPAIR
SUBJECT SEWERS
SUBJECT MANHOLES
EXISTING MANHOLES
EXISTING SEWERS
WATER MAIN
EXISTING GAS
EXISTING STORM DRAIN
EXISTING TREE
EXISTING UTILITY POLE
CONCRETE CURB AND GUTTER
(TO BE REPLACED FROM JOINT TO JOINT)
Docusign Envelope ID: E7490073-8D7E-4834-B3F8-F0E87B373330Docusign Envelope ID: C0BB6F87-19AB-4FD1-82BC-2A8297E89356
Oct 8, 2024 | 11:13 AM EDT
OF 6
GWALLAC
Revision
GWALLAC
Revision
GWALLAC
Revision
ALLERTON LANE
KILG
ORE
12900
077M
076M
004N
ROAD
12903
ALLERTON
LANE
12902
ALLERTON
LANE
12812
12813
12901
12903
12905
12902
S
S
02028004S
078K
ABANDONED
BREAK-IN
TAP
(CAPPED)
12904
12905
12820
12818
12906
S
SEWER REHABILITATION MANHOLES REHABILITATION
Asset ID Ex.
Diameter
Prop.
Diameter
Length Description Asset ID Depth Diameter Description
02029077S 6" 8" 156' REPLACE MAINLINE SEWER (UPSIZE FROM 6" TO 8"),
RENEW LATERALS & INSTALL CLEANOUTS
02029077M 9.9' 48" CEMENTITIOUS LINING
02029078S 6" 8" 149'
MATERIALS LIST
ITEM UNIT QTY
8" PVC SEWER MAIN LF 305
4" PVC LATERAL LF 202
8"X4" TEE EA 6
4" CLEANOUT EA 7
CCTV INFORMATION HOUSE CONNECTION CARD
PROPERTY
ADDRESS
BILLING
ADDRESS
REFERENCE
MH
CAMERA
DIRECTION
CCTV
FOOTAGE
TO HC
CCTV
POSITION
OF HC
EXISTING
SHC SIZE
EXISTING
SHC
MATERIAL
EXISTING
CLEANOUT
SHC
TYPE
LENGTH OF
EXISTING SHC
TREE
IMPACTS REMARKS
(US/DS) (LINEAR
FEET) (CLOCK) INCHES (YES/NO) (SINGLE/
DOUBLE) (LINEAR FEET) (COUNT-DBH)
12900 Kilgore Rd 12900 Kilgore Rd 02029077M DS 41 3 4 Asbestos Cement Yes Single 42 No Excavated Renewal of Lateral & Install
Cleanout
12901 Kilgore Rd 12901 Kilgore Rd 02029077M DS 50 9 4 Asbestos Cement Yes Single 20 No Excavated Renewal of Lateral & Install
Cleanout
12813 Kilgore Rd 12813 Kilgore Rd In 02029076M N/A N/A N/A 4 Asbestos Cement Yes Single 24 No Excavated Renewal of Lateral & Install
Cleanout
12902 Kilgore Rd 12902 Kilgore Rd 02029077M US 28 3 4 PVC Yes Single 42 No Reconnect
12903 Kilgore Rd 12903 Kilgore Rd 02029077M US 33 3 4 Asbestos Cement Yes Single 15 No Excavated Renewal of Lateral & Install
Cleanout
12904 Kilgore Rd 12904 Kilgore Rd 02029077M US 98 9 4 Asbestos Cement Yes Single 42 No Excavated Renewal of Lateral & Install
Cleanout
12905 Kilgore Rd 12905 Kilgore Rd 02029077M US 122 3 4 Asbestos Cement Yes Single 16 No Excavated Renewal of Lateral & Install
Cleanout
12906 Kilgore Rd 12906 Kilgore Rd 02029077M US 142 9 4 Asbestos Cement Yes Single 43 No Excavated Renewal of Lateral & Install
Cleanout
Sewer 02029077S/02029078S
REPLACE MAINLINE SEWER (UPSIZE FROM 6" TO 8"),
RENEW LATERALS & INSTALL CLEANOUTS
12901 KILGORE ROAD
PAINT BRANCH BASIN
217NE01
P5167B10
217NE01
KILGORE ROAD
WSSC CONTRACT: 62-5713
076M
077M
KILGORE ROAD
WSSC CONTRACT: 62-5713
077M
078K
NOT TO SCALE
NOTES:
1. Prior to excavation, contractor shall locate all utilities per Miss Utility (800) 257-7777.
2. All work shall be in accordance with the WSSC specification and contract documents.
3. Call WSSC Environmental at 301-206-2075 for tree removal and pruning.
4. Existing utilities and storm drains shown on this drawing are from GIS information and cannot be relied on for accuracy. The utilities have not been designated or test pitted. Contractor shall contact Miss Utility to have all existing utilities located.
ADC MAP
WSSC 200'S
JOB NO.
LEGEND
CRLRMH7338T22
ENGINEER:
NO
200'S
DATE
DATE REVISIONS
THESE DOCUMENTS CONTAIN
PRIVILEGED AND CONFIDENTIAL
INFORMATION WHICH SHALL NOT
BE REDISTRIBUTED WITHOUT
PRIOR WSSC APPROVAL
WSSC PIPELINE DESIGN DIVISION
PDD PROJECT MANAGER
JOB NUMBER
CRLRMH7338T22
TASK ORDER NO. 212
SANITARY SEWER REHABILITATION (SSR) MDE FUNDED PROJECT
PAINT BRANCH BASIN
SEWER INFRASTRUCTURE SECTION
WASHINGTON SUBURBAN SANITARY COMMISSION NAME: THE WILSON T. BALLARD COMPANY
ADDRESS: 17 GWYNNS MILL COURT, OWINGS MILLS, MD 21117
PHONE: (410) 363-0150
CONTACT : SHAWN BURNETT
EMAIL: SBURNETT@WTBCO.COM
5/28/2024 11:02 AM - PLOT DATE
PA
TH
T:
\W
SS
C \P
M
A1
O pt io n Ye ar \8
-1
.0
8_ Pa in t B ra nc h Ba si n\
D W
G s\
C
-1
.d w g
POINT/SPOT REPAIR
SUBJECT SEWERS
SUBJECT MANHOLES
EXISTING MANHOLES
EXISTING SEWERS
WATER MAIN
EXISTING GAS
EXISTING STORM DRAIN
EXISTING TREE
EXISTING UTILITY POLE
CONCRETE CURB AND GUTTER
(TO BE REPLACED FROM JOINT TO JOINT)
Docusign Envelope ID: E7490073-8D7E-4834-B3F8-F0E87B373330Docusign Envelope ID: C0BB6F87-19AB-4FD1-82BC-2A8297E89356
Oct 8, 2024 | 11:13 AM EDT
OF 6
GWALLAC
Revision
GWALLAC
Revision
GWALLAC
Revision
WASHINGTON SUBURBAN SANITARY COMMISSION W.S.S.C.
CONTRACT
UTILITY CONSTRUCTION DRAWING NO. S.C.1
SEDIMENT CONTROL DETAILS FOR
REVISED OCTOBER 2023
CRLRMH7338T22
SC-1
SC-1
Docusign Envelope ID: E7490073-8D7E-4834-B3F8-F0E87B373330Docusign Envelope ID: C0BB6F87-19AB-4FD1-82BC-2A8297E89356
File details come from the government source that posted it. Updated .