Part_7_-_WDIUP_Plans.pdf
PDF 19 MB Posted
- Attached to
- Washington District Infrastructure Upgrade Project State and local contract opportunity
- Solicitation number
- 26-023-ITB
- Issued by
- Yolo County, California
About this file
Summary
This is an improvement plan document for the Washington District Infrastructure Upgrade Project (CIP #35000) prepared for the City of West Sacramento, California. The project encompasses comprehensive water main improvements, sewer system rehabilitation, and fiber optic conduit installation across multiple streets in the Washington District, including work on Waterfront Place, B Street, C Street, E Street, F Street, 3rd Street, and 6th Street. The construction scope includes removal and replacement of existing water pipelines ranging from 6 to 16 inches in diameter; installation of new 8 to 12-inch water mains with associated gate valves, fire hydrants, and service connections; sewer main rehabilitation using cured-in-place pipe (CIPP) lining technology for approximately 2,000 linear feet across multiple streets; installation of new sanitary sewer mains and manholes; and placement of fiber optic conduit with pull boxes and junction boxes throughout the project area. The sealed bid responses are due no later than Thursday, April 30, 2026 at 2:00 pm, with all construction work required to be completed by December 31, 2026 in compliance with SACOG Green Means Go Grant requirements. The project presents significant logistical challenges due to its location within active public rights-of-way, proximity to residences and businesses, and required coordination with Union Pacific Railroad for pipeline installation under railroad tracks.
The improvement plans detail specific technical requirements including potholing and utility verification protocols, thrust block specifications, water pressure testing procedures, sewer manhole construction standards, and trenchless technology specifications for boring and jacking operations. Work must be performed during normal business hours (7 am to 5 pm Monday through Friday, excluding city holidays) unless prior approval is obtained. The contractor is responsible for calling Underground Service Alert (USA) at least 48 hours prior to excavation, coordinating with utility companies including PG&E, AT&T, and water/sewer departments, and maintaining service to existing customers during construction. Key utility representatives and city contacts are identified for coordination purposes. The project requires a preconstruction meeting with the City of West Sacramento Capital Projects Department and strict adherence to City of West Sacramento Standard Specifications and improvement standards. Specific attention is given to dewatering management, lateral and service connection procedures, CIPP rehabilitation methodology including root removal and cleaning, and restoration of landscapes and pavements to original condition.
View the file
Other files for this state and local contract opportunity
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
I-5
I-80
SACRAMENTO AVE
LIGHTHOUSE DR
C ST
KE
G
LE
D
R
RIVERBANK RD
TO
D
H U
N
TER
AVE
G ST
E ST
W CAPITOL AVE
H
AR
BO
R
B
LV
D
MICHIGAN BLVD
CUMMINS WY
CARRIE ST
HOBSON AVE
FOUNTAIN DR
ANDREW ST
ANNA ST
LISBON ST
UPRR
W
ES
TL
AK
E D
R
R
IVER
C R
EST D
R
F ST
N HARBOR BLVD
SM
IT
H B
LV
D
REED AVE
RIV
ERSID
E P
KW
Y
ST
IL
LW
AT
ER
R
D
SU
TT
ER
S
T
EVERGREEN AVE
MERKLEY AVE
G
IL
D E
AV
E
PE
C
AN
S
T
P ST
Q ST
K ST
I ST
CAPITOL MALL
3R D
S T
FR
O
N T
ST
3R D
S T
RI
VE
RF
RO
NT
S
T
DE
LT
A
LN
SNRR
SNRR
SACRAMENTO RIVER
AMERICAN RIVER
SAC
R
AM
EN
TO
R
IVER
RICHARDS BLVD
JI
BB
O O
M S
T
SPRR
I STBRIDGE
6T H
S T
CABALDON PKWY TOWERBRIDGE
5T H
S
T B STB ST
C ST
G ST
E ST
FR
O
N T
ST3R
D
S T
I STBRIDGE
6T H
S T
TOWERBRIDGE
5T H
S T
F ST
4T H
S T
7T H
S T
W
AT
ER
FR
O N
T
PL
2N D
S T
3R D
S T
5T H
S T
6T H
S T
SPRR
6TH ST
CALIFORNIA ST
D ST
WEST CAPITOL AVE
8T
H S
T
CABALDON PKWY
CABALDON PKWY
SAC
R
AM
EN
TO
R
IVER
WATER
IMPROVEMENTS
FIBEROPTIC
IMPROVEMENTS
WATER IMPROVEMENTS
WATER IMPROVEMENTS
SEWER
IMPROVEMENTS
WATER IMPROVEMENTS
SEWER
IMPROVEMENTS
WATER IMPROVEMENTS
SEWER
IMPROVEMENTS
SEWER
IMPROVEMENTS
FIBEROPTIC
IMPROVEMENTS
G
RAND ST
7TH ST
4T H
S T
B ST
DRAWING SCALE
HOR. SCALE:
VERT. SCALE:
SHEET NO. OF
REVIEWER:
DATE:
DRAFTER:
DESIGNER:
DRAWING INFO
CH
EC
KE
D
BY
DA
TE
DRAWING SCALE
RE
VI
SI
ON
D
ES
CR
IP
TIO
N
NO
ENGINEER'S STAMP
REY PROJ NO.CIP NO.
PROJECT PLANS FOR:
CITY OF WEST SACRAMENTO, CALIFORNIA
CITY PROJECT No. 35000
WASHINGTON DISTRICT INFRASTRUCTURE
UPGRADE PROJECT
UTILITY REPRESENTATIVES
REPRESENTATIVE TELEPHONE
PG & E
AT&T
CITY OF WEST SACRAMENTO
U.S.A.
FIRE DEPARTMENT
WAVE BROADBAND
U.S.A.
FIRE
CABLE TV
DRAINAGE
WATER
SEWER
TELEPHONE
ELECTRICITY
GAS
PG & E
(916) 296-6359
PUBLIC WORKS DEPT
ANNA SANTOS
DAN HUFFMAN (916) 202-2921
PUBLIC WORKS DEPT
PUBLIC WORKS DEPT (916) 617-4850
(800) 227-2600
(916) 617-4600
(916) 223-0123FRANK BARGIEL
CONSOLIDATED COMMUNICATIONS
COMMUNICATION
(916) 786-1513GRETCHEN HILDEBRAND
UTILITY
DAN HUFFMAN (916) 202-2921
CITY OF WEST SACRAMENTO
CITY OF WEST SACRAMENTO
UNDERGROUND SERVICE ALERT
GAS
KINDER MORAGN JASON BROTHERS (559) 333-1799
UNION PACIFIC RAILROAD
RAILROAD
(402) 544-8553KRIS JONES
(916) 617-4850
(916) 617-4850
VERIZON
TELEPHONE
(941) 906-6703CHUCK CZUMAK
BASIS OF BEARING
GENERAL NOTES:
DESCRIPTION
OWNER OF RECORD BENCH MARK
THE BEARINGS AND COORDINATES SHOWN HEREIN
ARE BASED ON THE CITY OF WEST SACRAMENTO
GEODETIC CONTROL NETWORK SHOWN AND
RECORDED IN BOOK 13 OF SURVEYS AT PAGE 61,
YOLO COUNTY RECORDS.
BRASS DISK SET IN THE TOP OF THE NORTHEAST
END OF THE SOUTHWEST WING WALL OF THE
SACRAMENTO NORTHERN RAILROAD OVERPASS, 29
FEET SOUTHEAST OF THE CENTER LINE OF THE
AVENUE, 5 FEET SOUTHEAST OF THE SOUTHWEST
END OF THE SOUTHEAST STEEL GUARDRAIL, 2.0
FEET SOUTHWEST OF THE SOUTHWEST END OF THE
SLOPING PART OF WINGWALL, AND ABOUT 3 1/2
FEET HIGHER THAN THE AVENUE.
ELEVATION = 16.12, NAVD 1988
CITY OF WEST SACRAMENTO
CAPITAL PROJECT DEPARTMENT
1110 WEST CAPITAL AVENUE
WEST SACRAMENTO, CA 95691
VERONICA GARCIA, P.E.
DESIGNED UNDER THE DIRECTION OF
DATE
CALL BEFORE YOU DIG
THE CONTRACTOR SHALL CALL "UNDERGROUND SERVICE
ALERT" (USA) AT 800-642-2444 AT LEAST 2 WORKING DAYS
PRIOR TO PERFORMING ANY EXCAVATION.
SHEET INDEX
C01 - TITLE SHEET
C02 - NOTES
C03 - DETAILS 1
C04 - DETAILS 2
C05 - DETAILS 3
C06 - CONNECT TO EXISTING DETAILS
C07 - DEMOLITION PLAN - WATERFRONT PL, B ST, C ST & E ST
C08 - WATER PLAN & PROFILE - E ST - 3RD & 2ND (BID ALT 3)
C09 - WATER PLAN & PROFILE - WATERFRONT PL (BID ALT 2) & B ST
C10 - WATER PLAN & PROFILE - 6TH ST (BID ALT 1) - C ST
C11 - PLAN - FO - RIVERFRONT & 3RD ST
C12 - PLAN - FO - 3RD ST
C13 - SEWER PLAN & PROFILE - 6TH ST TO C ST
C14 - PLAN - CIPP - F ST
C15 - PLAN - CIPP - E ST
C16 - PLAN - CIPP - 3RD ST
C17 - PLAN - CIPP - BACKYARD TO C ST & 4TH ST
VICINITY MAP
NOT TO SCALE
PROJECT
LOCATION
CITY REPRESENTATIVES
REPRESENTATIVE
LOUIS RAMIREZ (916) 617-4533
DEPARTMENT/ AGENCY
CONSTRUCTION INSPECTION
ENGINEERING AMBER WALLACE (916) 617-5327
FIRE DEPARTMENT
POLICE DEPARTMENT
JASON RIZZI
(NON - EMERGENCY DISPATCH)
(916) 617-4600
(916) 372-3375
UTILITIES MAINTENANCE
TRAFFIC
ROBERT SANTOS
JIMMY FONG
(916) 617-4845
(916) 617-4789
TELEPHONE
THESE IMPROVEMENT PLANS HAVE BEEN REVIEW BY THE CITY
OF WEST SACRAMENTO AND ARE IN GENERAL CONFORMANCE
WITH THE SCOPE AND INTENT APPROVED IN THE CAPITAL
IMPROVEMENT PROGRAM. CITY'S REVIEW AND APPROVAL OF
THESE PLANS DOES NOT RELEASE, DIMINISH, NOR REPLACE THE
DESIGNER'S IRRESPONSIBILITY FOR THEIR WORK.
DATEDAVID WONG
DEPARTMENT OF CAPITAL PROJECTS
LOCATION MAP
NOT TO SCALE
C01 C17 35000
JWF
KH, JQ
KH, JQ, NA
3/20/2026
C
IT
Y O
F W
E S T S
A C R
A M
E N T O
T
IT
L E S
H E E T
C
IP
WA
SH
IN
GT
ON
D
IS
TR
IC
T I
NF
RA
ST
RU
CT
UR
E U
PG
RA
DE
P
RO
JE
CT
IM
P R
O V E M
E N T P
L A N S F
O R
: C A L
IF
O R
N
IA
N.T.S.
AS NOTED
9303.001
03/20/20263/24/2026
DRAWING SCALE
HOR. SCALE:
VERT. SCALE:
SHEET NO. OF
REVIEWER:
DATE:
DRAFTER:
DESIGNER:
DRAWING INFO
CH
EC
KE
D
BY
DA
TE
DRAWING SCALE
RE
VI
SI
ON
D
ES
CR
IP
TIO
N
NO
ENGINEER'S STAMP
REY PROJ NO.CIP NO.
NOTES
1. ALL PUBLIC IMPROVEMENT CONSTRUCTION SHALL CONFORM TO THE CITY OF
WEST SACRAMENTO STANDARD SPECIFICATIONS AND SHALL BE SUBJECT TO A
CITY ENCROACHMENT PERMIT.
2. PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR IS RESPONSIBLE TO CONTACT
THE CITY OF WEST SACRAMENTO TO SCHEDULE A PRECONSTRUCTION
MEETING.
3. CONTRACTOR SHALL ADHERE TO NORMAL WORKING HOURS OF 7AM THROUGH
5PM MONDAY THROUGH FRIDAY, EXCLUDING CITY HOLIDAYS. THIS INCLUDES
HOLIDAY OBSERVANCES SUCH AS HALLOWEEN SHOULD THE CITY DESIGNATE
THEM. CONSTRUCTION OUTSIDE OF NORMAL WORKING HOURS, OR ON
SATURDAYS, SUNDAYS OR CITY HOLIDAYS MAY BE ALLOWED UPON PRIOR
APPROVAL BY THE CITY.
4. ANY WATER ENTERING THE SANITARY SEWER SYSTEM TO BE CONSTRUCTED
UNDER THE APPROVED PLANS SHALL NOT BE DISCHARGED TO THE EXISTING
SEWER SYSTEM. PLUGS SHALL BE INSTALLED IN EXISTING MANHOLES AS
NECESSARY TO PERMIT PUMPING THE NEW SYSTEM CLEAR OF WATER AND
DEBRIS PRIOR TO ACCEPTANCE BY THE CITY. CARE SHALL BE EXERCISED IN
LOCATING PLUGS TO AVOID INTERRUPTING SERVICE TO EXISTING
CONNECTIONS. MECHANICAL PLUGS OR MORTAR AND BRICK MUST BE USED.
INFLATABLE DEVICES ARE NOT ALLOWED.
5. A DEWATERING PLAN SHALL BE SUBMITTED TO THE ENGINEERING DIVISION FOR
APPROVAL PER DIVISION IV, SECTION 22 OF THE CITY STANDARD
SPECIFICATIONS PRIOR TO CONSTRUCTION.
6. ALL UTILITY LINES SHOWN ON PLANS ARE FOR REFERENCE ONLY. IT WILL BE THE
CONTRACTOR'S RESPONSIBILITY TO HAVE EACH UTILITY COMPANY LOCATE IN
THE FIELD THEIR MAIN SERVICE LINES AND LATERALS. THE CONTRACTOR MUST
NOTIFY MEMBERS OF THE UNDERGROUND SERVICE ALERT (U.S.A.) 48 HOURS IN
ADVANCE OF PERFORMING EXCAVATION WORK BY CALLING THE TOLL FREE
NUMBER 811 OR 1- 800-642-2444.
7. THE CONTRACTOR MUST FIELD VERIFY ALL EXISTING ROADWAY AND UTILITY
FACILITIES' LOCATIONS AND DEPTHS. IT WILL BE THE CONTRACTOR'S SOLE
RESPONSIBILITY TO LOCATE AND PROTECT ALL EXISTING ROADWAY AND UTILITY
FACILITIES, SO THAT NO DAMAGE RESULTS TO THEM DURING THE
PERFORMANCE OF THIS CONTRACT. THE CONTRACTOR WILL BE REQUIRED TO
COOPERATE WITH OTHER CONTRACTORS AND UTILITY COMPANIES INSTALLING
NEW STRUCTURES, UTILITIES AND SERVICES TO THE PROJECT. PAYMENT FOR
THIS WORK WILL BE CONSIDERED TO BE INCLUDED IN THE VARIOUS ITEMS OF
WORK.
8. ALL EXISTING UNDERGROUND UTILITIES MAY NOT BE SHOWN. THE CONTRACTOR
SHALL TAKE PRECAUTIONARY MEASURES TO PROTECT THESE UTILITIES. THE
CONTRACTOR SHALL DO NO EXCAVATION UNTIL ALL UTILITY COMPANIES AND
CITY OF WEST SACRAMENTO HAS BEEN NOTIFIED AND HAS BEEN GIVEN THE
OPPORTUNITY TO MARK FACILITIES IN THE FIELD. THE CONTRACTOR SHOULD
ANTICIPATE THE PRESENCE OF ABANDONED UTILITIES, AS RECORDS FROM
VARIOUS UTILITY OWNERS MAY BE INCOMPLETE OR INACCURATE. THE CITY WILL
NOT REIMBURSE THE CONTRACTOR FOR ANY COSTS OR TIME ASSOCIATED WITH
LOCATING, EXPOSING, OR REMOVING ABANDONED UTILITIES.
9. PRIOR TO TRENCHING FOR ANY WATER PIPE, THE CONTRACTOR SHALL VERIFY,
IN THE FIELD, THE SIZE AND LOCATION OF THE EXISTING PIPE AT THE POINT OF
CONNECTION. ANY DEVIATION FROM THE PLANS SHALL BE RESOLVED BY THE
ENGINEER PRIOR TO TRENCHING.
10. CONTRACTOR IS RESPONSIBLE FOR VERIFYING LOCATION, PROTECTING, AND
SUPPORTING ALL EXISTING UTILITY SERVICES TO INDIVIDUAL PARCELS.
11. ALL CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE
HEALTH AND SAFETY LAWS OF THE STATE OF CALIFORNIA AND CAL/OSHA
STANDARDS.
12. TRENCH BACKFILL SHALL BE COMPACTED IN ACCORDANCE WITH THE CONTRACT
DOCUMENTS.
13. ALL EXCESS MATERIALS AND/OR DEBRIS SHALL BE REMOVED UPON COMPLETION
OF INSTALLATION.
14. ALL LINES ABANDONED DURING CONSTRUCTION SHALL BE ABANDONED IN PLACE
AS DESCRIBED IN THE CONTRACT DOCUMENTS.
15. THE CONTRACTOR MUST MAINTAIN ACCESS FOR RESIDENTS AT ALL TIMES AND
PLACE TEMPORARY RAMPS TO AFFECTED RESIDENTS' DRIVEWAYS AT THE END
OF EACH WORKING DAY IF A DROP OFF GREATER THAN 0.15' EXISTS. RAMP
MATERIALS MUST BE CONSISTENT WITH THAT OF THE ROADBED (OR ROADWAY)
SURFACE THAT IT IS TO BE PLACED UPON. PAYMENT FOR THIS WORK MUST BE
CONSIDERED AS INCLUDED IN THE VARIOUS ITEMS OF WORK INVOLVED.
16. THE CONTRACTOR MUST EXERCISE DUE CAUTION AND CAREFULLY PRESERVE
SURVEY BENCH MARKS, CONTROL POINTS, REFERENCE POINTS AND ALL
SURVEY STAKES, AND MUST BEAR ALL EXPENSES FOR REPLACEMENT AND/OR
ERRORS CAUSED BY THEIR UNNECESSARY LOSS OR DISTURBANCE.
17. ALL CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH THE
LATEST EDITION OF THE CITY OF WEST SACRAMENTO IMPROVEMENT
STANDARDS AND THE PROJECT SPECIAL PROVISIONS.
18. POTHOLES SHALL BE STRATEGICALLY LOCATED TO MINIMIZE THE TOTAL
NUMBER OF EXCAVATIONS. WHERE UTILITIES ARE KNOWN OR ANTICIPATED TO
RUN PARALLEL OR CROSS ONE ANOTHER, THE CONTRACTOR SHALL, WHERE
FEASIBLE, POSITION POTHOLES SO THAT A SINGLE POTHOLE MAY BE USED TO
EXPOSE, VERIFY, AND RECORD HORIZONTAL AND VERTICAL LOCATION
INFORMATION FOR MULTIPLE UTILITIES. THE INTENT IS TO MAXIMIZE
INFORMATION OBTAINED FROM EACH POTHOLE WHILE MINIMIZING PAVEMENT
DISTURBANCE, SUBJECT TO APPROVAL OF THE CITY ENGINEER. POTHOLES WILL
BE COUNTED BASED ON THE NUMBER OF POTHOLES MADE AND NOT THE
NUMBER OF UTILITIES LOCATED.
WATER
1. ALL SANITARY SEWER CONSTRUCTION AND MATERIALS SHALL CONFORM TO THE
CITY OF WEST SACRAMENTO STANDARD SPECIFICATIONS (LATEST EDITION) AND
PROJECT TECHNICAL SPECIFICATIONS.
2. SANITARY SEWER PIPE LATERALS SHALL BE OF THE SAME MATERIAL TYPE AND
DESIGNATION AS THAT USED FOR THE MAIN SANITARY SEWER PIPE. THE USE OF
FOUR (4) INCH DIAMETER SDR-35 PVC SEWER PIPE AND FITTINGS WILL NOT BE
PERMITTED. FOUR (4) INCH DIAMETER SDR-26 PVC SEWER PIPES AND FITTINGS SHALL
BE USED FOR LATERALS FOR BOTH SDR-26 AND SDR-35 PVC SEWER MAINS.
3. SANITARY SEWER MANHOLES SHALL BE MIN. 4000 PSI CONCRETE CAST-IN-PLACE OR
PRECAST REINFORCED CONCRETE CONFORMING TO ASTM DESIGNATION C-478.
MANHOLES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE STANDARD DETAILS.
4. IRON CASTINGS FOR MANHOLE COVERS AND FRAMES SHALL CONFORM TO ASTM
DESIGNATION A-48, CLASS 35 AND BE OF THE DIMENSIONS SHOWN ON THE
STANDARD DETAILS.
5. ALL SEWER PIPE SHALL BE LAID WITH A MINIMUM OF 12 INCHES VERTICAL
CLEARANCE FROM WATER AND 6 INCHES CLEARANCE FROM ALL OTHER
IMPROVEMENTS AND UTILITIES, UNLESS OTHERWISE APPROVED BY THE CITY
ENGINEER. REFER TO THE PIPE COVER REQUIREMENTS IN SECTION 5 OF THE CITY
DESIGN STANDARDS FOR MINIMUM COVER.
6. PIPE ENTERING OR LEAVING MANHOLES OR OTHER STRUCTURES SHALL HAVE
JOINTS WITHIN 2-1/2 FEET OF THE MANHOLE BASE.
7. THE USE OF SADDLE ON THE SANITARY SEWER MAIN FOR SANITARY SEWER LATERAL
CONNECTIONS WILL NOT BE PERMITTED.
8. WHERE APPLICABLE, A TWO (2) INCH X TWO (2) INCH LETTER "S" SHALL BE STAMPED,
CHISELED, CUT, ETC. ON THE TOP OF ALL CONCRETE CURBS ON ALL SANITARY
SEWER LATERALS DIRECTLY ABOVE THE LOCATION WHERE THE LATERAL CROSSES
THE FLOW LINE OF THE GUTTER.
9. THE LATERAL LINE SHALL HAVE A CLEAN-OUT AT BACK EDGE OF SIDEWALK AS
SHOWN ON STANDARD DETAIL NO.401. LATERALS AND CLEANOUT SHALL NOT BE
LOCATED IN DRIVEWAYS UNLESS APPROVED OTHERWISE BY THE CITY ENGINEER.
10. WHEN CONNECTING TO AN EXISTING MANHOLE, FIRST CUT OUT AN OPENING IN THE
WALL OF THE MANHOLE. INSERT THE END OF THE PIPE THROUGH THE OPENING. THE
END OF THE PIPE SHALL BE FITTED WITH AN ELASTOMERIC COUPLING WITH A STEEL
BAND AND A RUBBER GASKET WATER STOP. THE OPENING AROUND THE PIPE SHALL
THEN BE PACKED WITH A STIFF MIX OF THOROUGHLY COMPACTED CEMENT MORTAR
COMPOSE OF ONE (1) PART TYPE II PORTLAND CEMENT AND THREE (3) PARTS CLEAN
SAND. CONNECTIONS SHALL BE CHECKED FOR WATER TIGHTNESS.
11. BEFORE ANY WORK IS STARTED ON ADJUSTING OR REPAIRING A MANHOLE, THE
CHANNELS IN THE BASE SHALL BE COVERED WITH STRIPS OF WOOD AND THE ENTIRE
BASE COVERED WITH A HEAVY PIECE OF CANVAS. THIS COVER SHALL BE KEPT IN
PLACE DURING ALL WORK, UPON COMPLETION OF THE WORK, THE WOOD STRIPS
AND THE CANVAS SHALL BE REMOVED FROM THE MANHOLE ALLOWING NO DEBRIS TO
FALL IN OR REMAIN IN THE MANHOLE.
12. TESTING OF SEWER LINES SHALL CONFORM TO SECTION 14 OF CITY STANDARD
SPECIFICATIONS.
13. ALL SEWER SERVICES SHALL BE CONNECTED TO THE NEW SEWER MAIN PER CITY OF
WEST SACRAMENTO STANDARD SPECIFICATIONS (LATEST EDITION).
14. THE MAJORITY OF THE EXISTING SEWER MAINS WITHIN THE PROJECT LIMITS WILL BE
REHABILITATED USING CURED-IN-PLACE PIPE (CIPP). THE CONTRACTOR SHALL
REVIEW AND VERIFY ALL SEGMENTS IDENTIFIED FOR CIPP REHABILITATION AND
SHALL PERFORM THE WORK IN ACCORDANCE WITH CITY OF WEST SACRAMENTO
STANDARD SPECIFICATIONS, PROJECT PLANS, PROJECT TECHNICAL SPECIFICATIONS
AND MANUFACTURER REQUIREMENTS.
GENERAL
1. ALL WATER CONSTRUCTION AND MATERIALS SHALL CONFORM TO THE
CITY OF WEST SACRAMENTO STANDARD SPECIFICATIONS (LATEST
EDITION).
2. WATER PIPE, FITTINGS, HYDRANTS AND VALVES MUST BE CAREFULLY
HANDLED AT ALL TIMES. ONLY SAFE, SUITABLE AND PROPER
EQUIPMENT AND APPLIANCES SHALL BE USED FOR THE LOADING,
HAULING, UNLOADING, HANDLING AND PLACING OF MATERIALS, SPECIAL
CARE SHALL BE EXERCISED SO THAT THE COATING ON PIPE, VALVES
AND FITTINGS WILL NOT BE DAMAGED. IF SUCH DAMAGE SHOULD
OCCUR, THE COATING SHALL BE REPAIRED TO THE SATISFACTION OF
THE CITY ENGINEER. CHAIN SLINGS WILL NOT BE PERMITTED. PIPE
LOADED ON TRUCKS OR STACKED ONE UPON ANOTHER SHALL BE
SUPPORTED ON WOODEN BLOCKING, PIPE HANDLED ON SKIDWAYS
SHALL NOT BE SKIDDED OR ROLLED AGAINST PIPE ALREADY ON THE
GROUND.
3. EACH SECTION OF PIPE AND EACH FITTING SHALL BE THOROUGHLY
CLEANED OUT BEFORE IT IS INSTALLED. ALL PIPE, FITTINGS, VALVES,
ETC. SHALL BE CAREFULLY LOWERED INTO THE TRENCH BY SUITABLE
TOOLS OR EQUIPMENT, IN SUCH A MANNER AS TO PREVENT DAMAGE TO
THE PIPE, LINING, COATING , FITTING OR OTHER APPURTENANCES.
UNDER NO CIRCUMSTANCES SHALL PIPE ACCESSORIES BE DROPPED
INTO THE TRENCH. BEVELS SHALL BE CUT OFF ENDS OF C900 PIPE
WHENEVER PIPE IS BEING INSTALLED USING MECHANICAL JOINT
FITTINGS.
4. THE PIPE SHALL BE LAID TRUE TO LINE, WITH NO VISIBLE CHANGE IN
ALIGNMENT AT ANY JOINT, UNLESS CURVED ALIGNMENT IS SHOWN ON
THE PLANS. IF CURVED ALIGNMENT IS SHOWN THE MAXIMUM
DEFLECTION AT ANY JOINT SHALL NOT EXCEED THE MANUFACTURER'S
RECOMMENDATION FOR THE TYPE OF PIPE AND JOINT BEING USED.
5. THRUST BLOCKS OF MIN. 4,000 PSI CONCRETE SHALL BE CAST-IN-PLACE
AT ALL BENDS, BEHIND EACH TEE, OR EACH CROSS, WHICH IS VALVED IN
SUCH A MANNER THAT IT CAN ACT AS A TEE, AND AT THE BACK OF FIRE
HYDRANTS UNLESS DESIGNATED OTHERWISE ON THE PLANS. THE
THRUST BLOCK SHALL EXTEND FROM THE FITTING TO UNDISTURBED
SOIL, SHALL BE KEPT CLEAR OF THE JOINTS, AND SHALL BE OF SUCH
BEARING AREAS AS TO ASSURE ADEQUATE RESISTANCE TO THE FORCE
TO BE ENCOUNTERED. CLASS "A" CONCRETE FOR THRUST BLOCKS
SHALL CONFORM TO SECTION 90-10 MINOR CONCRETE OF THE STATE
STANDARD SPECIFICATIONS. A CERTIFICATE OF COMPLIANCE SHALL BE
SUBMITTED TO THE CITY ENGINEER PRIOR TO THE PLACEMENT OF ANY
CLASS "A" CONCRETE TO BE FURNISHED MEETS ALL CONTRACT
REQUIREMENTS INCLUDING MINIMUM CEMENT CONTENT SPECIFIED.
THE CONTRACTOR SHALL INSURE THAT THE NUTS AND BOLT HEADS OF
BOLTED CONNECTIONS ARE NOT COVERED BY CONCRETE OR FROM
MATERIALS. THRUST BLOCKS SHALL BE INSTALLED IN CONFORMANCE
WITH THE STANDARD DETAILS.
6. VALVES SHALL BE SET PLUMB AND PROPERLY FITTED TO THE
ADJACENT SECTIONS OF THE MAIN. A VALVE BOX SHALL BE INSTALLED
OVER EACH VALVE.
7. JOINT RESTRAINTS SHALL HAVE 8-MIL POLYETHYLENE ENCASEMENT
CONFORMING TO AWWA C105. SUCH ENCASEMENT SHALL BE SECURED
USING 10 MIL WRAPPING TAPE.
8. THE WATER SERVICE LINE SHALL BE CONSIDERED AS A PART OF THE
MAIN FOR THE PURPOSE OF HYDROSTATIC TEST. WATER SERVICES MAY
BE BORED UPON APPROVAL OF THE CITY ENGINEER.
9. THE CONTRACTOR SHALL MAKE CONNECTIONS TO THE EXISTING MAINS
WHERE INDICATED ON THE PLANS. THE NEWLY INSTALLED FACILITIES
ARE TO BE KEPT ISOLATED FROM THE CITY SYSTEM UNTIL
BACTERIOLOGICALLY ACCEPTABLE.
10. SERVICE IN EXISTING MAINS CAN BE INTERRUPTED ONLY UPON
AUTHORIZATION BY THE CITY ENGINEER WHO WILL SPECIFY THE TIME
AND DURATION OF THE OUTAGE. THE CONTRACTOR SHALL NOTIFY ALL
AFFECTED USERS IN WRITING AT LEAST 48 HOURS IN ADVANCE OF
SERVICE INTERRUPTION, USING PRINTED FORMS APPROVED BY THE
CITY.
11. WATER SERVICE INTERRUPTION OF RESIDENCES OR BUSINESSES
SHALL NOT EXCEED FOUR (4) HOURS AND SHALL BE PRECEDED BY
NOTIFICATION TO RESIDENTS OR BUSINESS A MINIMUM OF TWO (2)
WORKING DAYS (48 HOURS) PRIOR TO SHUTDOWN OF SERVICE. WATER
SHUTDOWNS SHALL NOT OCCUR DURING A HOLIDAY WEEK. THE
NOTIFICATION OF WATER SERVICE INTERRUPTION SHALL BE IN A FORM
APPROVED BY THE CITY ENGINEER AND SHALL BE SUBMITTED TO THE
CITY ENGINEER FOR APPROVAL A MINIMUM OF FIVE (5) DAYS PRIOR TO
WATER SERVICE INTERRUPTION.
12. CONTRACTOR TO PROTECT EXISTING WATER IMPROVEMENTS, WHICH
MAY INCLUDE (BUT NOT LIMITED TO) EXISTING WATER LINES, THRUST
BLOCKS, FIRE HYDRANTS AND LATERALS.
13. WATER SERVICE SHALL BE MAINTAINED AT ALL TIMES DURING
CONSTRUCTION.
14. CONTRACTOR WILL MAKE ALL CONNECTIONS TO EXISTING WATER
MAINS. AFTER NEW WATER MAIN IS COMPLETED, ALL EXISTING WATER
LINES ARE TO REMAIN IN SERVICE UNTIL ABANDONED. CONTRACTOR
WILL ABANDON EXISTING WATER LINES AND FIRE HYDRANTS AS SHOWN
ON THE PLANS. COORDINATE WITH THE CITY INSPECTOR.
15. ALL WATER LINES SHALL BE PRESSURE TESTED, DISINFECTED, FLUSHED
AND TESTED FOR BACTERIA IN CONFORMANCE WITH THE CONTRACT
DOCUMENTS PRIOR TO FINAL ACCEPTANCE BY THE CITY OF WEST
SACRAMENTO.
16. SEPARATION OF NEW WATER MAINS FROM OTHER PIPELINES MUST
MEET THE REQUIREMENTS OF THE CALIFORNIA CODE OF REGULATIONS,
TITLE 22, SECTION 64572.
17. MEGA-LUG RESTRAINTS AT MJ FITTINGS AND BELL-HARNESS
RESTRAINTS ON PIPE JOINTS REQUIRING RESTRAINING DUE TO THRUST
AND/OR DDW SEPARATION REQUIREMENTS SHALL BE UTILIZED. THE USE
OF GASKET LOK IS NOT PERMITTED.
SEWER
SD
W
SD
W
SSSS
DD
2"2"2"2"
1"1"1"1"
8"W
18"SD
10"SS10"SS
18"SD
8"W
SS
AB - AGGREGATE BASE
AC - ASPHALT CONCRETE
ARV - AIR RELEASE VALVE
AVE - AVENUE
BLDG - BUILDING
BOV - BLOW-OFF VALVE
BOW - BACK OF WALK
COMM - COMMUNICATION
CIP - CAST IRON PIPE
CMP - CORRUGATED METAL PIPE
CL - CENTERLINE
DI - DRAINAGE INLET
DIA - DIAMETER
ELEC - ELECTRIC
ELEV - ELEVATION
EP - EDGE OF PAVEMENT
(E) - EXISTING
(F) - FUTURE
FH - FIRE HYDRANT ASSEMBLY
FL - FLOW LINE
INTX - INTERSECTION
JT - JOINT TRENCH
LF - LINEAR FOOT
MH - MANHOLE
NTS - NOT TO SCALE
PC - POINT OF CURVATURE
PCC - PORTLAND CEMENT CONCRETE
PP - POWER POLE
PT - POINT OF TANGENCY
(P) - PROPOSED
PVC - POLYVINYL CHLORIDE
R - RECYCLED WATER
R/W - RIGHT OF WAY
SVC - SERVICE
SD - STORM DRAIN
SS - SANITARY SEWER
ST - STREET
TBB - TOP BACK OF BERM
TBC - TOP BACK OF CURB
TBW - TOP BACK OF SIDEWALK
STA - STATION
W - WATER
WTR - WATER
WM - WATER METER
WS - WATER SERVICE
XING - CROSSING
ABBREVIATIONS LEGEND
1. ALL UNDERGROUND UTILITIES TO BE FIELD VERIFIED WITH REGARDS TO LOCATION,
DEPTH, TYPE OF MATERIAL, ETC.. PRIOR TO EXCAVATION OR CONSTRUCTION.
2. REFER TO CONTRACTOR CONSTRUCTION METHODOLOGY FOR CASING PIPE
PLACEMENT AND OPEN TRENCH VERTICAL SHORING.
3. BORING & JACKING SHALL BE LOCATED A MINIMUM OF 10' FROM THE EDGE OF
PAVEMENT IN RURAL AREAS, OR AT LEAST 5' BEYOND THE CONCRETE CURB AND
GUTTER OR AC DIKE IN URBAN AREA, OR AT LEAST 5' BEYOND THE TOE OF SLOPE OF
EMBANKMENTS.
4. PROTECTED BY PLACEMENT OF 6' CHAIN LINK FENCE OR TYPE-K-BARRIER AROUND
THEM
5. REFLECTORS SHALL BE AFFIXED TO THE SHORING ON ALL SIDES FACING TRAFFIC.
6. PITS SHALL NOT CREATE A HAZARD TO THE TRAVELING PUBLIC. DAMAGED CITY
FACILITIES SHALL BE REPLACED IN-KIND OR REPAIRED TO THEIR ORIGINAL STATE.
7. ALL PITS SHOULD HAVE CRUSHED-ROCK AND SUMP AREA TO CLEAR GROUNDWATER
AND WATER USED TO CLEAN THE CASINGS. PIT SHALL BE LINED WITH FILTER FABRIC
WHEN GROUNDWATER IS FOUND AND PUMPING IS REQUIRED.
8. TEMPORARY TYPE-K RAILING SHALL BE PLACED AT A 20:1 TAPER OR AS OTHERWISE
DIRECTED BY THE CITY REPRESENTATIVE TO MAINTAIN THE INTEGRITY OF THE
ADJACENT TRAVEL LANE.
9. UTILITY INSTALLATION PLACED BY BORE & JACK SHALL BE BASED ON THESE PLANS
AND AREMA MANUAL FOR RAILWAY ENGINEERING, VOLUME 1, CHAPTER 1, PART 5:
UTILITIES, AND SPECIFICATIONS FOR TRENCHLESS TECHNOLOGY PROJECTS",
LATEST EDITION.
10. PRIOR TO PROCEEDING WITH THE WORK, THE CONTRACTOR SHALL SUBMIT TO THE
ENGINEER FOR REVIEW AND APPROVAL A WRITTEN DESCRIPTION OF MATERIALS,
EQUIPMENT, METHOD, AND SEQUENCE OF OPERATIONS PROPOSED TO BE USED TO
FURNISH AND INSTALL THE CASING PIPE, OR THE DIRECT JACK PIPE, INCLUDING THE
CONVEYANCE PIPE GRADES.
11. CONTRACTOR SHALL ALSO PROVIDE DETAIL DRAWINGS AND STRUCTURAL
CALCULATIONS TO THE ENGINEER INDICATING THE MATERIALS AND METHODS TO BE
USE TO SHORE THE EXCAVATED JACKING AND RECEIVING PITS SIGNED BY A
STRUCTURAL ENGINEER LICENSED BY THE STATE OF CALIFORNIA. APPROVAL OF THE
PROPOSED METHOD BY THE ENGINEER SHALL NOT RELIEVE CONTRACTOR OF THE
FULL RESPONSIBILITY OF MAKING A SATISFACTORY INSTALLATION MEETING THE
CRITERIA SET FORTH HEREIN AND ON THE PLANS.
12. UPPR CONTACT: KRIS JONES (402)544-8553
UPPR (BORING & JACKING)
FIBEROPTIC CONDUIT
1. CONTRACTOR SHALL VERIFY ALL EXISTING UTILITY LOCATIONS AND DEPTHS PRIOR
TO COMMENCING WORK. POTHOLING IS REQUIRED TO POSITIVELY LOCATE ALL
UTILITIES WITHIN 5 FEET OF THE BORE ALIGNMENT.
2. HORIZONTAL DIRECTIONAL DRILLING (HDD), IF APPLICABLE, SHALL BE PERFORMED IN
ACCORDANCE WITH INDUSTRY BEST PRACTICES (E.G., NASTT GOOD PRACTICES
GUIDELINES) AND MANUFACTURER'S RECOMMENDATIONS.
3. CONTRACTOR SHALL SUBMIT AN HDD INSTALLATION PLAN FOR REVIEW PRIOR TO
MOBILIZATION. THE PLAN SHALL INCLUDE ENTRY AND EXIT LOCATIONS, BORE
PROFILE, EQUIPMENT, DRILLING FLUID MANAGEMENT, AND CONTINGENCY
MEASURES.
4. MINIMUM CONDUIT COVER SHALL BE 30 INCHES BELOW FINISHED GRADE UNLESS
OTHERWISE SHOWN ON THE PLANS OR DIRECTED BY THE ENGINEER.
5. CONTRACTOR SHALL MAINTAIN SEPARATION OF AT LEAST 12 INCHES VERTICAL AND
24 INCHES HORIZONTAL FROM EXISTING UTILITIES UNLESS OTHERWISE APPROVED.
6. DRILLING FLUID SHALL BE CONTAINED, MANAGED, AND DISPOSED OF IN
ACCORDANCE WITH ALL APPLICABLE REGULATIONS. NO DRILLING FLUID SHALL BE
DISCHARGED TO STORM DRAINS, WATERWAYS, OR ADJACENT PROPERTIES.
7. CONDUITS SHALL BE INSTALLED AS A CONTINUOUS RUN BETWEEN DESIGNATED
STRUCTURES UNLESS OTHERWISE SHOWN. PULL BOXES OR VAULTS SHALL BE
PROVIDED AS INDICATED.
8. CONTRACTOR SHALL PULL A MANDREL AND PROVIDE A DETECTABLE PULL TAPE OR
TRACER WIRE IN ALL CONDUITS UPON COMPLETION OF INSTALLATION.
9. CONTRACTOR SHALL REPAIR OR REPLACE, AT NO COST TO THE CITY, ANY DAMAGE
TO EXISTING UTILITIES, STRUCTURES, OR IMPROVEMENTS CAUSED BY THE HDD
OPERATIONS.
10. CONTRACTOR SHALL RESTORE ALL DISTURBED SURFACES, PAVEMENTS, AND
LANDSCAPING TO EQUAL OR BETTER CONDITION THAN EXISTING.
11. BORE PATH DEVIATIONS GREATER THAN 1 FOOT FROM THE PLAN ALIGNMENT SHALL
BE REPORTED IMMEDIATELY TO THE ENGINEER FOR REVIEW AND APPROVAL.
CO
C02 C17 35000
JWF
KH, JQ
KH, JQ, NA
3/20/2026
C
IT
Y O
F W
E S T S
A C R
A M
E N T O
N O
T E S
C
IP
WA
SH
IN
GT
ON
D
IS
TR
IC
T I
NF
RA
ST
RU
CT
UR
E U
PG
RA
DE
P
RO
JE
CT
IM
P R
O V E M
E N T P
L A N S F
O R
: C A L
IF
O R
N
IA
E
FO
G
C
C03 C17 35000
JWF
KH, JQ
KH, JQ, NA
3/20/2026
C
IT
Y O
F W
E S T S
A C R
A M
E N T O
D E T A
IL
S
C
IP
WA
SH
IN
GT
ON
D
IS
TR
IC
T I
NF
RA
ST
RU
CT
UR
E U
PG
RA
DE
P
RO
JE
CT
IM
P R
O V E M
E N T P
L A N S F
O R
: C A L
IF
O R
N
IA
HOR. SCALE:
VERT. SCALE:
REY PROJ NO.
SHEET NO. OF
REVIEWER:
DATE:
DRAFTER:
DESIGNER:
DRAWING INFO
CH
EC
KE
D
BY
DA
TE
DRAWING SCALE
RE
VI
SI
ON
D
ES
CR
IP
TIO
N
NO
ENGINEER'S STAMP
CIP NO.
B
B
A A
NEW CHANNEL
EXISTING PCC BENCH TO BE
CHISELED OUT AND RESURFACED (E)MANHOLE
1/2" CEMENT MORTAR"DIA" X 1' STUB
(E)BENCH
(E)OUTLET
(E)CHANNEL
(E)PRECAST CONCRETE
MANHOLE
CORE CUT HOLE (DIA = OD+ 2" MAX)
OR PER MANUFACTURE'S
REQUIREMENT FOR BOOT
SECURELY FASTEN "DIA" X 1' STUB INTO
CORED HOLE WITH CEMENT MORTAR
(E)PIPE
CHISEL OUT (E)CONCRETE
CHANNELS AND BENCHES TO
FORM NEW SMOOTH
CHANNELS AND SURFACE
WITH 1/2" CEMENT MORTAR
"DIA" X 1' STUB
CORE CUT HOLE
(DIA = OD+ 2" MAX)
OR PER
MANUFACTURER'S
REQUIREMENTS FOR
BOOT
(E)PIPE
(E)CONCRETE
MANHOLE
SECTION ELEVATION A-A
SECTIONAL PLAN OF BASE
SECTIONAL ELEVATION B-B CHANNEL BASE
FOR PIPE TO BE ABANDONED
FOR PIPE TO REMAIN IN SERVICE
(E)PIPE TO BE CUT
COMPACTED BEDDING MATERIAL
PER SPECIFICATIONS
LINE CAP COUPLING
SAWCUT PIPE TO BE
ABANDONED PER
SPECIFICATIONS
4' MIN
JOINT TO CUT END
FOR PIPE NOT TO REMAIN IN
SERVICE, FILL PIPE END
W/CONCRETE.
MUSHROOM CONCRETE 6"
BEYOND END OF PIPE
2' MIN
SAWCUT PIPE & FILE TO
REMOVE SHARP EDGES
UNDISTURBED SOUL
6" TYP
6" TYP
6" TYP
ENCASE COUPLING
IN CONCRETE
fc=2500psi
SEE DETAIL 'A', BELOW
12"
8"
DETAIL 'A'
NOTES:
1. REFERENCE CITY OF WEST SACRAMENTO DETAIL 404 FOR SANITARY
SEWER MANHOLE STRUCTURE
2. SIDEWALK REPAIR
1EX. CONCRETE CLASS "A" CONCRETE COLLAR
2 4" PCC / 4" AB PER CITY STANDARD DETAIL #201
(E)PIPE
(E)MANHOLE
INNER WALL
(E)PIPE
(E)MANHOLE
OUTER WALL (E)PIPE
PLAN VIEW
PLUG WITH CONCRETE 12"
INTO PIPE. SMOOTH TO
CONFORM TO INSIDE WALL
OF MANHOLE
C04 C17 35000
JWF
KH, JQ
KH, JQ, NA
3/20/2026
C
IT
Y O
F W
E S T S
A C R
A M
E N T O
D E T A
IL
S
C
IP
WA
SH
IN
GT
ON
D
IS
TR
IC
T I
NF
RA
ST
RU
CT
UR
E U
PG
RA
DE
P
RO
JE
CT
IM
P R
O V E M
E N T P
L A N S F
O R
: C A L
IF
O R
N
IA
HOR. SCALE:
VERT. SCALE:
REY PROJ NO.
SHEET NO. OF
REVIEWER:
DATE:
DRAFTER:
DESIGNER:
DRAWING INFO
CH
EC
KE
D
BY
DA
TE
DRAWING SCALE
RE
VI
SI
ON
D
ES
CR
IP
TIO
N
NO
ENGINEER'S STAMP
CIP NO.
CONNECT TO (E)SEWER MANHOLE
N.T.S.
CUT AND CAP
N.T.S.
SEWER REPAIR
N.T.S.
SEWER MANHOLE IN SIDEWALK
N.T.S. 6
MANHOLE PLUG
N.T.S. 5
C05 C17 35000
JWF
KH, JQ
KH, JQ, NA
3/20/2026
C
IT
Y O
F W
E S T S
A C R
A M
E N T O
D E T A
IL
S
C
IP
WA
SH
IN
GT
ON
D
IS
TR
IC
T I
NF
RA
ST
RU
CT
UR
E U
PG
RA
DE
P
RO
JE
CT
IM
P R
O V E M
E N T P
L A N S F
O R
: C A L
IF
O R
N
IA
HOR. SCALE:
VERT. SCALE:
REY PROJ NO.
SHEET NO. OF
REVIEWER:
DATE:
DRAFTER:
DESIGNER:
DRAWING INFO
CH
EC
KE
D
BY
DA
TE
DRAWING SCALE
RE
VI
SI
ON
D
ES
CR
IP
TIO
N
NO
ENGINEER'S STAMP
CIP NO.
1 2
CONNECT TO EXISTING WATER SYSTEM - LOCATION F
A. INSTALL VERTICAL BEND TO MATCH (E)W PIPE CONNECTION
ELEVATION, IF NECESSARY.
B. CONTRACTOR SHALL VERIFY EXISTING WATER PIPE ALIGNMENT
AND AN ADDITIONAL HORIZONTAL BEND MAY BE REQUIRED AT
NO ADDITIONAL COMPENSATION.
NOTES
(N)8" W PVC
PIPE
(E)8" W PIPE
(E) 8" W PIPE
CONTRACTOR TO
VERIFY (E)ALIGNMENT
E STREET
BID ALTERNATIVE 3
E ST. TO RIVER WALK TRAIL
1. 8" FLANGE TEE
2. 8" FLANGE x MJ ADAPTER
3. 8" FLANGE x MJ GATE VALVE
CONNECT TO EXISTING WATER SYSTEM - LOCATION A
N.T.S.
A. INSTALL VERTICAL BEND TO MATCH (E)W PIPE CONNECTION
ELEVATION, IF NECESSARY.
NOTES
B STREET
(E)8" W PVC PIPE
(N)8" W
PVC PIPE
REMOVE (E)BOV
1. 8" MJ 45° BEND (ROLLED)
CONNECT TO EXISTING WATER SYSTEM - LOCATION C
N.T.S.
A. INSTALL VERTICAL BEND TO MATCH (E)W PIPE CONNECTION
ELEVATION, IF NECESSARY.
NOTES
C STREET
(N)12" W
PVC PIPE
(E)12" W PIPE
(E) 12" GATE VALVE
CONTRACTOR TO
VERIFY FLANGE
OR MJ
(E)12" W PIPE
(N)12" W
PVC PIPE
1. 12" FLANGE TEE
2. 12" FLANGE GATE VALVE
3. 12" FLANGE x MJ ADAPTOR
CONNECT TO EXISTING WATER SYSTEM - LOCATION B
N.T.S.
A. INSTALL VERTICAL BEND TO MATCH (E)W PIPE CONNECTION
ELEVATION, IF NECESSARY.
B. THE EXISTING GATE VALVE IS ASSUMED TO BE FLANGED.
CONTRACTOR MUST VERIFY THE CONNECTION TYPE IN
ADVANCE OF MAKING TIE-IN.
NOTES
N D
S T R
E E T
8" W PVC PIPE
(E)8" W PIPE
(E)6" GATE VALVE
(E) 6" W PIPE
ASSUMED MATERIAL DIP
1 2
1. 8"x6" FLANGE TEE
2. 8" FLANGE x MJ ADAPTOR
CONNECT TO EXISTING WATER SYSTEM - LOCATION D
N.T.S.
A. INSTALL VERTICAL BEND TO MATCH (E)W PIPE CONNECTION
ELEVATION, IF NECESSARY.
NOTES
(E)8" PVC W PIPE
(E)8" PVC W PIPE
(N)12" W
PVC PIPE
BID ALTERNATIVE 1
JACK & BORE TO 6TH STREET
1. 8" FLANGE TEE
2. 8" FLANGE GATE VALVE
3. 8" FLANG x MJ ADAPTER
4. 12" x 8" FLANGE REDUCER
5. 12" FLANGE 45° BEND (ROLLED)
6. 12" FLANGE x MJ ADAPTOR
CONNECT TO EXISTING WATER SYSTEM - LOCATION E
N.T.S.
A. INSTALL VERTICAL BEND TO MATCH (E)W PIPE CONNECTION
ELEVATION, IF NECESSARY.
B. CONTRACTOR SHALL BID THIS CONNECTION UTILIZING A 14"X8"
TAPPING SLEEVE.
C. SCHEMATIC OF TEE AND REDUCER SHOWN FOR ALTERNATE IF
DETERMINED IN THE FIELD A TAPPING SLEEVE CANNOT BE UTILIZED.
NOTES
8" W PVC
PIPE
(E) 14" W PVC PIPE
(E) 14" W PVC PIPE
W A T E R
F R
O N T P
L
BID ALTERNATIVE 2
WATERFRONT PLACE FH LATERAL
1. 14" FLANGE TEE (SEE NOTE B)
2. 14" x 8" FLANGE REDUCER
3. 8" FLANGE x MJ GATE VALVE (FH ISOLATION VALVE)
4. 14" FLANGE x MJ ADAPTER
2 34
C06 C17 35000
JWF
KH, JQ
KH, JQ, NA
3/20/2026
C
IT
Y O
F W
E S T S
A C R
A M
E N T O
C O
N N E C T T
O E
X
IS
T
IN
G D
E T A
IL
S C
IP
WA
SH
IN
GT
ON
D
IS
TR
IC
T I
NF
RA
ST
RU
CT
UR
E U
PG
RA
DE
P
RO
JE
CT
IM
P R
O V E M
E N T P
L A N S F
O R
: C A L
IF
O R
N
IA
HOR. SCALE:
VERT. SCALE:
REY PROJ NO.
SHEET NO. OF
REVIEWER:
DATE:
DRAFTER:
DESIGNER:
DRAWING INFO
CH
EC
KE
D
BY
DA
TE
DRAWING SCALE
RE
VI
SI
ON
D
ES
CR
IP
TIO
N
NO
ENGINEER'S STAMP
CIP NO.
F
B DCA
E
CONNECT TO EXISTING GENERAL NOTES:
1. EACH CONNECT TO EXISTING WATER SYSTEM DETAIL IS ITS OWN BID ITEM.
2. NEW WATER PIPE SHOWN TO BE INSTALLED IS NOT INCLUDED IN THE BID PRICE FOR THAT RESPECTIVE CONNECT TO EXISTING LOCATION.
3. ALL FITTINGS, VALVES, REMOVAL OF (E)BOV, ETC. ARE INCLUDED IN THE BID PRICE FOR THAT RESPECTIVE CONNECT TO EXISTING LOCATION.
4. CONTRACTOR SHALL VERIFY ALL CONNECTION POINT ELEVATIONS AND SHALL BE INCLUDED IN THE CONNECT TO EXISTING WATER SYSTEM BID ITEM.
ADDITIONAL VERTICAL/HORIZONTAL FITTINGS MAY BE REQUIRED AND ADDITIONAL COMPENSATION WILL NOT BE ALLOWED.
5. PROVIDE COUPLINGS TO CONNECT THE NEW WATER PIPE AND FITTINGS TO THE EXISTING WATER PIPE AS NEEDED.COUPLINGS ARE NOT SHOWN FOR
CLARITY PURPOSES. THIS SHALL BE INCLUDED IN THE VARIOUS BID ITEMS FOR CONNECT TO EXISTING WATER SYSTEM.
SS SS SS SS SS SS SS
SD
SD SD SD SD SD SD
S
D D
D
DD
S
CO
10"SS
"S
S
8"SS
"S
D
"S D
15"SD
SS
SS
SS
SS
SS
SS
SS
SSSS
W
W W
W
W W
W
W
W W
SD
SS
W
WW
C C C
C C
S
S
S S
S
CO
CO
T
T
T
S
UU
S
W W
W W
C C C
C
C C
8"SS
8"
SS
8"SS
8"
SS
15"SD
"S
D
15"SD
8"SD
12"SD
"S
D 8"
SD
12"SS
6" W
12" W
8" W
8" W
6" W
S
D
FO
T
KP
SD
SS SS
CO
W
W
S
SD
D 15"SD
14" W
8"SS S
6" W
SS
SSSS SS
SSSSSS
SS
SS
SS
SS
SS
SS
SS
SS SS SS
SS
SS
SS
SS
SS
SS
SD
SD
SD SD SD SD SD SD
SD
SD
SD
SD
SD
S
S
S
S
S
S
S
S S
S
D
D
D
D
D
S
CO
8"SS
8"SS
"S
S
"S
S
8"SS
8"
SS
8"SS
8"
SS
12"SD
12"SD15
"S
D
"S D
33"SD33"SD33"SD
"S
D
"S
S
12"SS
OHE
OH
E
O H
E
OHE
O H
E W
W
W
W
W
W W W W W
W
W
W
W W W
W
W
W
W
W
W W W W
SS
SS
SS
SS
SS
SS SS
T
T
T
U
U
U
S
8"S S
18"SD
"S
D
8"
SS
15"SD
8"SS
8"SS
"S
D
"S
D
" W
6" W
16" W
8" W
" W
6" W
O H
E
O H
E
CO CO
G
G
C07 C17
JWF
KH, JQ
KH, JQ, NA
3/20/2026
C
IT
Y O
F W
E S T S
A C R
A M
E N T O
D E M
O L
IT
IO
N P
L A N W
A T E R
F R
O N T P
L B
S T C S
T
E S
T C
IP
WA
SH
IN
GT
ON
D
IS
TR
IC
T I
NF
RA
ST
RU
CT
UR
E U
PG
RA
DE
P
RO
JE
CT
IM
P R
O V E M
E N T P
L A N S F
O R
: C A L
IF
O R
N
IA
35000 9303.001
HOR. SCALE:
VERT. SCALE:
SHEET NO. OF
REVIEWER:
DATE:
DRAFTER:
DESIGNER:
DRAWING INFO
CH
EC
KE
D
BY
DA
TE
DRAWING SCALE
RE
VI
SI
ON
D
ES
CR
IP
TIO
N
NO
ENGINEER'S STAMP
REY PROJ NO.CIP NO.
SCALE IN FEET
0 40'20' 80'
1. PRIOR TO (E)WATER TO BE CUT AND CAPPED PIPE SHALL BE
DRAINED TO FULLEST EXTENT POSSIBLE.9
2. CONTRACTOR TO POTHOLE EXISTING WATERLINES TO CONFIRM
EXACT SIZE, DEPTH AND LOCATION OF WHERE ABANDONMENT
WILL OCCUR.
3. EXISTING WATER PIPE, WATER SERVICES AND FIRE HYDRANTS ARE
TO REMAIN IN SERVICE WHILE NEW SERVICES, WATER PIPES AND
FIRE HYDRANTS ARE INSTALLED. CONTRACTOR SHALL SUBMIT A
CONNECTION AND ABANDONMENT PLAN TO THE CITY FOR
APPROVAL PRIOR TO ANY SYSTEM OUTAGES OR CONNECTIONS.
CONTRACTOR SHALL COORDINATE CROSS OVERS TO NEW
SYSTEM WITH CITY AND MINIMIZE OUTAGE DURATIONS.
4. A MINIMUM OF 2 CONNECTIONS TO EXISTING SYSTEM ARE
REQUIRED PRIOR TO ANY SERVICE OR FIRE HYDRANT CROSS
OVERS.
5. EMPTY METER/UTILITY BOXES SHALL BE REMOVED AND SITE
RESTORED TO MATCH ADJACENT. CONTRACTOR SHALL CONFIRM
WITH CITY REPRESENTATIVE BEFORE REMOVING.
6. DEMOLISH, DISMANTLE AND REMOVE THE FIRE HYDRANT DOWN TO
THE BURIED HYDRANT ELBOW. CUT AND CAP (E)FIRE HYDRANT
ELBOW PER DETAIL 4 ON SHEET C04. CUT & CAP BOTH ENDS TO BE
INCLUDED IN THIS BID ITEM. SALVAGE EXISTING HYDRANT AND
DELIVER TO PUBLIC WORK'S CORP YARD.
7. WATER LINES TO BE ABANDONED, CUT & CAPPED, AND VALVES
ABANDONED IN PLACE WHERE THEY WILL BE CONNECTED TO AN
ACTIVE LINE WILL REQUIRE THE PROPER THRUST BLOCK AND
TRANSITION PIPING TO MEET CITY OF WEST SACRAMENTO
STANDARDS.
8. ONCE THE LINE IS ABANDONED AND THE GATE VALVE SHOWN TO
BE ABANDONED IS NOT CONNECTED TO AN ACTIVE MAIN, THEN
DETAIL 2 ON SHEET C03 CAN BE FOLLOWED. GATE VALVES SHOWN
TO BE ABANDONED BUT CONNECTED TO AN ACTIVE MAIN SHALL BE
REMOVED AND SALVAGED AND RETURNED TO CORP YARD. A BLIND
FLANGE SHALL BE PLACED IN ITS PLACE WITH PROPER THRUST
BLOCKS. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR
THESE LOCATIONS.
SYMBOLS ENLARGED FOR CLARITY
ABANDON (E)PIPE IN-PLACE
LEGEND
CUT AND CAP (E) PIPE
(SEE DETAIL 4 ON SHEET C04)
PLAN SCALE:
E ST
2N D
ST
3R D
ST
WATERFRONT PL
C ST
5TH
ST
CALIFORNIA ST
6TH ST
REMOVE & SALVAGE
(E)FIRE HYDRANT.
SEE NOTE 6.
REMOVE & SALVAGE
(E)FIRE HYDRANT.
SEE NOTE 6.
ABANDON (E)VALVE
(SEE DETAIL 2 ON SHEET C03)
BID ALTERNATIVE 2
BID ALTERNATIVE 3
SEE NOTE 8
SEE NOTE 8
SEE NOTE 8
TOP=23.67
+8 0.
(E
)S D
X
IN
G
+3 5.
"T
EE
+3 2.
(E
)C O
M M
X
IN
G
+5 2.
(E
)W X
IN
G
+4 5.
(E
)S S
XI
N
G
227.56 LF OF 8" PVC C900 WATER
(E)12" SEWER
(E)15" STORM DRAIN
" M
IN
(E)8" SEWER
(E)8" WATER
EG @ TOP OF PIPE
ELEV: 23.2
ELEV: 23.1
EG @ ℄ LINE
+9 3.
" F H
173.98 LF 8" PVC
C900 WATER
EG @ TOP OF PIPE
ELEV: 36.7
KP
SS SS SS
SD SD SD
S
D
D
DD
S
SS
SS
SS
W
W W
W W
C C C
C C
S
S
S S
S
CO
CO
UU
W W
C C C
C
C C
8"SS
8"
SS
8"SS
8"
SS
15"SD
"S
D
15"SD
8"SD
12"SD
"S
D 8"
SD
12"SS
6" W
12" W
8" W
8" W
T
20 21 22 2350 50 50 50
APN 010-374-012 APN 010-374-013
(E)BOW
R/W
(TYP)
8" W
8" W
21+35.88 (13.68'L)
CONNECT TO (E)WATER SYSTEM
1 - 8" GATE VALVE
1 - 8" TEE
CONTRACTOR TO VERIFY (E)WATER ALIGNMENT
22+36.84 (13.63'L)
45° BEND
22+64.21 (40.99'L)
45° BEND
22+99.99 (40.97'L)
11.25° BEND
23+97.60 (60.45'L)(E)FENCE
(E)FENCE
22+57.78 (34.11'L)
BEGIN CONSTRUCTION OF
WATER MAIN
IN LANDSCAPE AREA
1 - 8"x6" REDUCER
1 - 6" GATE VALVE
(E)EP
(E)TBC
(E)EP
(E)TBC
(E)BOW
(E)TBC CONNECT TO
(E)IRRIGATION
(E)WATER TO BE
ABANDONED
W
W W6" W
(E)CONC RAMP
(E)CONCRETE
WALKWAY
8" W
8" W
CONNECT TO
(E)RESTROOM
BUILDING
(E)BOW
(E)EDGE OF CONCRETE
WALKWAY
23+61.42 (32.78'L)
45° BEND
23+97.60 (60.45'L)
45° BEND INSTALL FIRE HYDRANT
PER CITY STD. #515
24+09.75 (151.60'L)
45° BEND
1 - 8"x6" REDUCER
1 - 6" GATE VALVE
C O
N N
EC
T TO
(E)IR
R
IG
ATIO
N
(E)WATER TO
BE ABANDONED
(E)W
ATER
TO
BE
ABAN
D
O N
ED
SEE SHEET C07
CL
LINE DATA
L1
L2
BEARING
S81° 31' 48"E
S81° 31' 48"E
LENGTH
379.73'
82.17'
POTABLE WATER
PIPE LINE DATA
L10
L11
L12
L13
L14
L15
L16
BEARING
S81° 30' 21"E
N53° 29' 39"E
S81° 30' 21"E
S73° 56' 09"E
N61° 03' 51"E
N16° 03' 51"E
N61° 03' 51"E
LENGTH
100.95'
38.70'
35.78'
61.97'
45.55'
91.95'
4.51'
SIZE
8"
8"
8"
8"
8"
8"
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
9.
(E )2
9.
(E )2
9.
(E )3
0.
(E )3
0.
(E )3
0.
(E )3
0.
(E )3
2.
(E )3
2.
(E )3
3.
(E )3
4.
.9
.1
.3
.4
.6
.8
.0
.2
.4
.7
.0
.4
.7
.0
.2
.5
.9
.3
.7
.2
.8
.4
(E )3
4.
(E )3
5.
(E )3
5.
(E )3
5.
(E )3
6.
(E )3
7.
(E )3
8.
(E )3
8.
(E )3
8.
(E )3
9.
(E )3
9.
(E )3
9.
(E )4
0.
(E )4
0.
(E )4
0.
(E )4
0.
(E
.3
.0
.6
.3
.9
.4
.0
.5
.0
.4
.8
.1
.5
.7
.0
.2
SCALE IN FEET
0 40'20' 80'
DRAWING SCALE
HOR. SCALE:
VERT. SCALE:
SHEET NO. OF
REVIEWER:
DATE:
DRAFTER:
DESIGNER:
DRAWING INFO
CH
EC
KE
D
BY
DA
TE
DRAWING SCALE
RE
VI
SI
ON
D
ES
CR
IP
TIO
N
NO
REY PROJ NO.CIP NO.
E ST
(S
EE
T H
IS
S
H
EE
T)
M A T C H
L
IN
E S
T A
E S
T R
E E T
S T A
.4
C L
W
A T E R
2ND ST
(SEE THIS SHEET)
MATCHLINE STA 23+50 (E STREET)
STA 12+41.76 (CL 8" WATER)
SCALE IN FEET
0 40'20' 80'
CL 8" WATER
23+0022+0021+0020+00
25+0024+00
MATCH POINT
ENGINEER'S STAMP
C08 C17
JWF
KH, JQ
KH, JQ, NA
3/20/2026
C
IT
Y O
F W
E S T S
A C R
A M
E N T O
W A T E R
P L A N
P R
O F
IL
E E
S T
R D
N D
B
ID
A
L T
C
IP
WA
SH
IN
GT
ON
D
IS
TR
IC
T I
NF
RA
ST
RU
CT
UR
E U
PG
RA
DE
P
RO
JE
CT
IM
P R
O V E M
E N T P
L A N S F
O R
: C A L
IF
O R
N
IA
3 4
F
CONNECTION NOTES:
F CONNECT TO (E)W SYSTEM - F
· CONNECT TO (E)W SYSTEM PER
CONNECTION DETAIL F, SHEET C06.
EXIST GRADE
ABOVE W PIPE
PROPOSED GRADE
AT TOP OF W PIPE
EXIST GRADE
ABOVE W PIPE
PROPOSED GRADE
AT TOP OF W PIPE
1. CONTRACTOR SHALL RESTORE ANY
DAMAGE TO LANDSCAPE AREA CAUSED
DURING INSTALLATION OF WATER MAIN
AND COST SHALL BE INCLUDED IN
VARIOUS WORK.
2. CONTRACTOR TO VERIFY EXISTING
IRRIGATION AND RESTROOM SERVICE
CONNECTIONS AND RECONNECT TO
NEW 8" WATER PIPE.
3. CONTRACTOR SHALL CONTACT THE
FIRE DEPARTMENT 72 HOURS IN
ADVANCE PRIOR TO REMOVING OLD
HYDRANT AND INSTALLING THE NEW
ONE. CONFIRM WITH FIRE DEPARTMENT
THE ALLOTTED TIME FOR FIRE
HYDRANT TO BE OUT OF SERVICE.
CONSTRUCTION NOTES:
BID ALTERNATIVE 3
SD
SS SS
CO
W
W
S
SD
D 15"SD
14" W
8"SS S
6" W
9 10 11 12 13 14 50 50 50 50
(E)TBC
R/W
(TYP)
8" W
10+78.96 (15.01' L)
CONNECT TO (E)WATER SYSTEM
1 - 14" TEE W/ (1)14"x8" REDUCER
1 - 8" GATE VALVE (EAST)
10+78.68 (6.28'R)
22.5° BEND
10+62.82 (44.25'R)
22.5° BEND
10+62.40 (53.41'R)
FH PER STD DTL 515
2"
+5 2.
(E
)2 " B
O V
+6 2.
" F H
+5 8.
(E
)6 " F
H
+1 1.
(E
)S D
M H
+3 1.
(E
)S
SM
H +3
7.
(E )C
O M
M
(E)TOP 18.52
EG @ ℄ LINE
(E)8" SEWER
(E)15" STORM DRAIN
(E)14" WATER
SS
SS SS
SD
SD
S S
D
8"SS
8"SS
W W W
8"
SS
21"SD
8" W
8" W
T T
T
FO FO FO FO FO FO
FO
2 3
50 50
R/W
(TYP)
8" W
CO
(E)TBC
(E)EP
(E)TBC
(E)EP
(E)GATE
(E)BIKE PATH
4+61.26 (0.61'L)
11.25° BEND
6+14.70 (0.34'R)
CONNECT TO (E)WATER SYSTEM
1 - 8"x6" TEE
(FH LATERAL ASSUMED TO BE 6")
5+12.95 (5.46'R)
22.5° + 11.25° BEND
5+68.45 (1.11'L)
45° BEND
5+42.57 (10.20'R)
1" ARV
(E)EP
(E)BOW (E)FENCE
(E)EP
(E)TBC (E)GATE
3+41.26 (8.33'L)
CONNECT TO (E)WATER SYSTEM
45° BEND 3+55.60 (4.64'R)
45° BEND
(E)EP
3+44.40 (17.62'L)
REMOVE (E)BOV
2"
+4 1.
(E
)2 " B
O V
+4 5.
(E
)6 "x
8" x8
" T
EE
+4 7.
(E
)S
SM
H
+1 8.
(E
)S
SM
H
+1 4.
(E
)F H
+4 1.
(E
)S D
M H
TOP=25.59
TOP=29.60
TOP=37.01
TOP=33.34
R=1200.0'
R=1500.0'
R=778.3'
+1 1.
(E
)T
EL
EP
H
O N
E
+4 6.
(E
)C O
M M
+4 2.
" A R
V
1"1"
+1 4.
"T
EE
EG @ ℄ LINE
321.03 LF OF 8" PVC C900 WATER
" M
IN
(E)8" SEWER
(E)8" WATER
(E)8" WATER
EG @ TOP OF PIPE
ELEV: 32.7
EG @ TOP OF PIPE
LINE DATA
L3
BEARING
N8° 28' 07"E
LENGTH
469.92'
CL
LINE DATA
L4
L5
L6
BEARING
S81° 16' 16"E
S77° 42' 34"E
S6° 39' 20"W
LENGTH
171.37'
203.27'
62.16'
CL
CURVE DATA
C1
LENGTH
60.89'
RADIUS
44.29'
DELTA
78°46'27"
CLPOTABLE WATER
PIPE LINE DATA
L17
L18
L19
BEARING
S80° 41' 15"E
S58° 51' 37"E
S78° 52' 14"E
LENGTH
20.30'
41.15'
9.17'
SIZE
8"
8"
8"
POTABLE WATER
PIPE LINE DATA
L20
L21
L22
L23
L24
BEARING
S35° 33' 25"E
S80° 33' 25"E
S70° 18' 25"E
S36° 33' 25"E
S8° 26' 35"W
LENGTH
19.34'
105.79'
50.99'
49.67'
46.29'
SIZE
8"
8"
8"
8"
+2 1.
" F H
+5 7.
(E
)S D
M H
+6 9.
(E
)S
SM
H +6
8.
2.
5° B
EN
D
+5 3.
2.
5°
B
EN
D
EG @ TOP OF PIPE
(E)8" SEWER
121.49 LF OF 8"
PVC C900 WATER
ELEV: 17.4
ELEV: 23.6
ELEV: 17.4
(E )2
6.
(E )2
6.
(E )2
7.
(E )2
7.
(E )2
7.
(E )2
7.
(E )2
7.
(E )2
7.
(E )2
7.
(E )2
7.
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
8.
(E )2
9.
(E )2
9.
(E )3
0.
(E )3
1.
.1
.9
.3
.3
.3
.3
.3
.3
(E )2
5.
(E )2
5.
(E )2
5.
(E )2
5.
(E )2
5.
(E )2
5.
(E )2
5.
(E )2
5.
(E )2
5.
(E )2
5.
(E )2
5.
(E )2
5.
(E )2
5.
(E )2
5.
(E )2
6.
(E )2
6.
(E )2
6.
(E )2
7.
(E )2
7.
(E )2
8.
(E )2
8.
(E )2
9.
(E )3
0.
(E )3
0.
(E )3
1.
(E )3
2.
(E )3
3.
(E )3
4.
(E )3
4.
(E )3
5.
(E )3
6.
(E )3
7.
(E )3
8.
(E )3
8.
(E )3
9.
(E )3
9.
(E )4
0.
(E )4
0.
(E )4
0.
(E )4
1.
(E )4
1.
(E )4
1.
(E )4
0.
(E )4
0.
(E )4
0.
(E )3
9.
(E )3
9.
(E )3
8.
(E )3
7.
.3
.1
.9
.8
.8
.7
.6
.4
.2
.8
.5
.0
.5
.9
.2
.5
.7
.9
.9
.0
.9
.8
.4
.7
.0
.3
.6
SCALE IN FEET
0 40'20' 80'
DRAWING SCALE
HOR. SCALE:
VERT. SCALE:
SHEET NO. OF
REVIEWER:
DATE:
DRAFTER:
DESIGNER:
DRAWING INFO
CH
EC
KE
D
BY
DA
TE
DRAWING SCALE
RE
VI
SI
ON
D
ES
CR
IP
TIO
N
NO
REY PROJ NO.CIP NO.
WATERFRONT PL
WATERFRONT PL
11+0010+00
SCALE IN FEET
0 40'20' 80'
2ND ST3RD ST
02+0001+00
B ST
03+00 04+00 05+00 06+00
40 40
ENGINEER'S STAMP
C09 C17
JWF
KH, JQ
KH, JQ, NA
3/20/2026
C
IT
Y O
F W
E S T S
A C R
A M
E N T O
W A
TE
R P
LA
N
P R
O
FI
LE
W
A
TE
R
FR
O N T
P L
(B
ID
A
LT
B
S T
C
IP
WA
SH
IN
GT
ON
D
IS
TR
IC
T I
NF
RA
ST
RU
CT
UR
E U
PG
RA
DE
P
RO
JE
CT
IM
P R
O V E M
E N T P
L A N S F
O R
: C A L
IF
O R
N
IA
A CONNECT TO (E)W SYSTEM - A
· CONNECT TO (E)W SYSTEM PER
CONNECTION DETAIL A, SHEET C06.
B CONNECT TO (E)W SYSTEM - B
· CONNECT TO (E)W SYSTEM PER
CONNECTION DETAIL B, SHEET C06.
A
B
CONNECTION NOTES:
E
E CONNECT TO (E)W SYSTEM - E
· CONNECT TO (E)W SYSTEM PER
CONNECTION DETAIL E, SHEET C06.
CONNECTION NOTES:
FIRE HYDRANT PROFILE
EXIST GRADE
ABOVE W PIPE
PROPOSED GRADE
AT TOP OF W PIPE
EXIST GRADE
ABOVE W PIPE
PROPOSED GRADE
AT TOP OF W PIPE
10+00 11+009+00
BID ALTERNATIVE 2
X
X
SS
SS
SS
SS
SS
SS
SS SS SS
SS SS SS SS SS SS
SD
SD
SD
SD
SD
SD
SD
S
S
S
S
S
D
D
CO
8"SS
33"SD
15"SD
15"SS
12"SS
O H
E
OHE
OHE
OHE
OHE
W
W
W W
W
W
W
W
W
W
W
W W
FO
FO
FO
FO
FO
FO
SS
SS
SS
SS
S
T
U
U
U
8"SS
18"SD
36"SD
8"SS
8"SS
15"SD
24"SD
16" W
6" W
W
OHE
O H
E O
H E
OHE OHE
O H
E
8" W
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
CO
CO
G
G
5 6 7 8 9
50 50 50 50
APN 010-193-005
APN
010-193-007APN 010-193-009
APN 010-194-011APN 010-191-011
(E)RR TRACK
(E)FENCE
(E)GUARDRAIL
(E)EP
R/W
(TYP)
S
12" W
S
CO
CO
CO
5+06.42 (8.54'L)
CONNECT TO (E)WATER SYSTEM
1 - 8" TEE W/(1) 12"x8" REDUCER
2 - 8" GATE VALVES (NORTH, EAST)
8+90.84 (14.93'L)
11.25° BEND 9+28.15 (14.92'L)
22.5° BEND
10+07.73 (2.85'L)
11.25° BEND
11+42.43 (19.37'L)
5+09.94 (12.09'L)
45° BEND
5+53.64 (12.89'L)
END 20" STEEL CASING
6+64.98 (12.18'L)
END 20" STEEL CASING
112 LF OF 20" STEEL CASING
7+27.59 (13.06'L)
2" BOV OR
1" ARV (BID ALT 1)
R/W
(TYP)
1" WATER SERVICE LINE
CONNECT TO (E)WATER METER
1" WATER SERVICE LINE
CONNECT TO (E)WATER METER
1" WATER SERVICE LINE
CONNECT TO (E)WATER METER
(E)W
ATER
M
ETER
6+16.98 (12.57'L)
CL OF RAIL
5+98.64 (12.49'L)
CL OF RAIL
FIRE HYDRANT LATERAL
TO GO UNDER (E)WATER
10+13.31 (38.56'R)
FH PER STD DTL 515
40 LF OF LATERAL
10+17.76 (1.70'L)
12X6" TEE
(1) 12" GATE VALVE (SOUTHEAST)
(1) 6" GATE VALVE (SOUTHWEST)
SEE SHEET C07 (TYP.)
(E)6" AC WATER
(ABND)
+3 0.
(E
)S
SM
H
+2 7.
F
U T
SS
M
H
+0 9.
(E
)2 " B
O V
+9 7.
(E
)6 "x
6" x6
" T
EE
+1 4.
(E
)W B
EN
D
+2 4.
(E
)W B
EN
D
+3 8.
(E
)1 6" x1 6" x8 " T
EE
+4 7.
(E
)W B
EN
D
+0 2.
(E
)1 6" x1 6" x8 " T
EE
+5 7.
(E
)1 6" x1 6" x8 " T
EE
2"
+9 5.
(E
)2 " B
O V
+5 7.
(E
)1 1 2"
G
AS
+2 4.
S
SM
H
+3 8.
(E
)1 8"
S D
+5 3.
(E
)S D
M H
+4 6.
(E
)S
SM
H
+9 4.
(E
)S D
D I
+2 1.
(E
)S D
M H
+1 0.
(E
)S
SM
H
+2 6.
(E
)G
AS
+1 4.
(E
)S
SM
H
+4 6.
(E
)F O
+2 8.
(E
)F O
+1 2.
(E
)J T
+4 5.
(E
)3 0"
S D
(A
BN
D
+7 0.
(E
)2 4"
S D
TOP=20.51
TOP=19.07
+5 3.
B
EG
IN
D
IP
W
AT
ER
P
IP
E
IN
S
TE
EL
C
AS
IN
G
+6 4.
E
N D
D
IP
W
AT
ER
P
IP
E
IN
S
TE
EL
C
AS
IN
G
+0 0.
(E
)W B
EN
D
+0 6.
" T
EE
W / 1
2" x8
" R
ED
U C
ER
(E)TOP 20.33
TOP=20.51
+4 3.
(E
)W B
EN
D
(E)8" PVC WATER
(E)15" SEWER
(E)18" STORM DRAIN
(E)16" WATER
(E)6" WATER
(E)8" SEWER
(E)8" SEWER
(E)36" STORM DRAIN (E)33" STORM DRAIN
(E)12" SEWER
+2 7.
" B
LO
W -O
FF
1"
A R
V
FO
R B
ID
A
LT
+4 9.
(E
)G
AS
X
IN
G
2"
+1 7.
2"
TE
E
181.31 LF OF 12" PVC OF DR-18
C900 WATER
12" DUCTILE IRON WATER PIPE
IN 20" STEEL CASING
(BID ALT 1)
" M
IN
(P)40" SSMH
(SEE SHEET C13)
ELEV: 19.6
ELEV: 19.4
EG @ TOP OF PIPE
93.53 LF OF 12" PVC OF DR-14
C900 WATER
STA 9+08.90 TO 9+82.43
51.19 LF OF 12" PVC OF DR-18
C900 WATER (BID ALT 1)
68.10LF OF 12" PVC OF DR-18
C900 WATER (BID ALT 1)
21.13 LF OF 12" PVC OF DR-14
C900 WATER
STA 10+78.87 TO 11+00
96.44 LF OF 12" PVC OF DR-18
C900 WATER
SS
SS
SS SS
SS
SSSS
SS SS SS
SD
SD
SD SD SD SD SD
S
S
S
S S
S D
D
D
8"SS
8"SS
"S
S
"S
S
8"SS
8"
SS
8"SS
12"SD
12"SD15
"S
D
"S D
33"SD33"SD33"SD
"S
S
12"SS
OHE
W
W W W W W
W
W
W
W
W
W
W W W W
FO
FO
FO FO FO
SS
SS
SS SS
T
T
15"SD
8"SS
16" W
8" W
" W
6" W
FO
FO FO FO
FO FO FO
FO
FO FO FO
FO
FO FO FO
12 13 14
50 50 50
APN
010-193-004
APN
010-193-003
APN
010-193-002
APN
010-193-011
R/W
(TYP)
S
12" W
APN
010-481-001
11+30.31 (19.57'L)
22.5° BEND
11+42.43 (19.37'L)
22.5° BEND
14+08.03 (1.96' R)
CONNECT TO (E)WATER SYSTEM
1 - 12" TEE
2 - 12" GATE VALVE (WEST, SOUTH)
1" WATER
SERVICE LINE
CONNECT TO
(E)WATER METER
1" WATER SERVICE
LINE CONNECT TO
(E)WATER METER
1" WATER SERVICE
LINE CONNECT TO
(E)WATER METER
+3 2.
(E
)S
SM
H
+9 5.
(E
)S
SM
H
+7 6.
(E
)S
SM
H
+0 9.
(E
)W T
EE
+2 5.
(E
)W B
EN
D
+3 2.
(E
)W B
EN
D
+5 2.
(E
)S
SM
H (A
BN
D
+6 8.
(E
)E
LE
C
TR
IC
+7
2.
(E )G
AS
+7
3.
(E )S
SM
H
+7 5.
(E
)1 2"
S S
+8 9.
(E
)S
SM
H +8
9.
(E )1
0" S
S
+5 9.
(E
)S
SM
H
+1 9.
(E
)S D
M H
+2 7.
(E
)S
SM
H +2
7.
(E )1
5" S
D
+5 9.
(E
)G
AS
+9 2.
(E
)G
AS
+6 1.
(E
)F O
+9 9.
(E
)S D
M H
+8 2.
(E
)F O
TOP=19.07
+0 8.
2" x1
2" x1
2" T
EE
+0
9.
(E )1
6" x1
6" x1
6" x1
2" C
R O
SS
(E)8" SEWER
(E)12" SEWER
(E)8" SEWER
(E)6" WATER
(E)16" WATER
(E)33" STORM DRAIN
(E)8" SEWER
288.43 LF OF 12" PVCDR-14 C900
WATER
EG @ ℄ LINE
" M
IN
20.00 LF OF 12" PVC DR-14 WATER
+90.97 22.25° BEND
ELEV: 18.0
+59.20 22.25° BEND
ELEV: 18.0
+65.09 22.25° BEND
ELEV: 15.5
+85.09 22.25° BEND
ELEV: 15.5
ELEV: 18.0
ELEV: 18.0
EG @ TOP OF PIPE
LINE DATA
L7
L8
L9
BEARING
N8° 44' 42"E
S82° 49' 16"E
S79° 23' 26"E
LENGTH
383.86'
272.60'
5.50'
CL CL
CURVE DATA
C3
C2
LENGTH
112.23'
221.22'
RADIUS
234.72'
234.72'
DELTA
27°23'44"
53°59'59"
POTABLE WATER
PIPE LINE DATA
L25
L26
L27
L28
L29
L30
L31
BEARING
N36° 30' 33"W
N8° 29' 27"E
N19° 44' 43"E
N42° 14' 43"E
N51° 25' 59"E
N75° 59' 43"E
S81° 38' 28"E
LENGTH
5.00'
382.54'
39.63'
83.06'
128.00'
13.13'
270.67'
SIZE
12"
12"
12"
12"
12"
12"
12"
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
3.
(E )2
5.
(E )2
7.
(E )2
9.
(E )2
4.
(E )2
4.
(E )2
3.
(E )2
3.
(E )2
3.
(E )2
3.
(E )2
3.
(E )2
3.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.5
.4
.2
.1
.9
.7
.5
.4
.2
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
.0
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
1.
(E )2
1.
(E )2
1.
(E )2
1.
(E )2
1.
(E )2
1.
(E )2
1.
(E )2
1.
(E )2
1.
(E )2
1.
(E )2
1.
(E )2
1.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
(E )2
2.
.0
.0
.0
.0
.0
.9
.9
.8
.8
.7
.7
.6
.6
.5
.4
.4
.4
.4
.4
.4
.4
.4
.4
.4
.4
.4
.4
.6
.6
.6
.0
(E )3
1.
(E )3
2.
(E )3
2.
(E )3
2.
(E )3
1.
(E )3
1.
(E )3
0.
(E )3
0.
(E )2
9.
(E )2
9.
(E )2
8.
(E )2
7.
(E )2
6.
(E )2
5.
(E )2
5.
(E )2
4.
C10 C17
JWF
KH, JQ
KH, JQ, NA
3/20/2026
C
IT
Y O
F W
E S T S
A C R
A M
E N T O
W A T E R
P L A N
P R
O F
IL
E
T H
S T
B
ID
A L T
C S
T C
IP
WA
SH
IN
GT
ON
D
IS
TR
IC
T I
NF
RA
ST
RU
CT
UR
E U
PG
RA
DE
P
RO
JE
CT
IM
P R
O V E M
E N T P
L A N S F
O R
: C A L
IF
O R
N
IA
1" = 4' 1" = 40'
SCALE IN FEET
0 40'20' 80'
DRAWING SCALE
HOR. SCALE:
VERT. SCALE:
SHEET NO. OF
REVIEWER:
DATE:
DRAFTER:
DESIGNER:
DRAWING INFO
CH
EC
KE
D
BY
DA
TE
DRAWING SCALE
RE
VI
SI
ON
D
ES
CR
IP
TIO
N
NO
REY PROJ NO.CIP NO.
6TH ST
(SEE THIS SHEET)
MATC
HLI
NE
STA
1+0
0.0
10+009+008+007+005+00 6+00
11+00
SCALE IN FEET
0 40'20' 80'
13+00 14+0012+00
(SEE THIS SHEET)
M A T C H
L
IN
E S
T A
.0
C ST
U P R
R
CALIFORNIA ST
SACRAMENTO AVE
T H S
T
MATCH POINT
(P)SEWER SHOWN
FOR REFERENCE
(SEE SHEET C13)
5TH ST
11+00
ENGINEER'S STAMP
5TH ST
CONSTRUCTION NOTES:
1. FIELD VERIFY LOCATIONS FOR EXISTING WATER SERVICE
LINES, TAPS, AND APPURTENANCES; TYP. RECONNECT
EXISTING WATER SERVICES PER CITY STANDARD #501
2. UPPR GUIDELINES MUST BE FOLLOWED FOR WORK WITHIN
THEIR RIGHT OF WAY.
3. WHERE NEW 1" WATER SERVICES WILL BE INSTALLED.
CONTRACTOR MUST TURN THE OLD CORP STOP FROM THE
EXISTING LINE IN THE OFF POSITION.
4. TRAFFIC SIGNAL LOOPS SHALL BE REPAIRED IN PLACE.
2 3
CONNECTION NOTES:
C CONNECT TO (E)W SYSTEM - C
· CONNECT TO (E)W SYSTEM PER
CONNECTION DETAIL C, SHEET C06.
D CONNECT TO (E)W SYSTEM - D
· CONNECT TO (E)W SYSTEM PER
CONNECTION DETAIL D, SHEET C06.
D C
2 3
6 7
EXIST GRADE
ABOVE W PIPE
PROPOSED GRADE
AT TOP OF W PIPE
EXIST GRADE
ABOVE W PIPE
PROPOSED GRADE
AT TOP OF W PIPE
BID
ALTERNATIVE 1
BID ALTERNATIVE 1
W W W
W W W
W W
W W
W
EE
E E E
E
E
E
EE
E E
E E E
SD SD
SD
SD
SD
SD
E
T T
E
T T
T T
E
G G
G
G
G G G G
G G
G G
E E E
E
ETFO
FO
FO
FO
FO
FO FO
FO
FO FO
FO
FO
FO
FO
IVIV
D
D
D
D
M H
M H
M H
M H
TS
TS
TS
TS
TS
TS
TS TS
TS
E
E
TS
TS
TS
TS
E
E
EV
EV
EV
EV
EV
EV
C
C
C
C
C
C
CVCV
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
C
TS
15+27.6 (33.7'R);
(N)JUNCTION BOX - LANDSCAPE
(SINGLE STACK)
17+45.2 (34.4'R);
(N)JUNCTION BOX - LANDSCAPE
(DOUBLE STACK)
10+60.3 (43.8'R);
(N)JUNCTION BOX - HARDSCAPE
(DOUBLE STACK)
9.7'
SS
SS
SS
S
S
DS
COCO
12"SS
12"SS
8"SS
12"SS
18"SD
48"SD
12"SD
15"SD
12"SD
D D
SS SS SS SS
SDSD SD
W
W
W
W
W
W
W W
W W
W W
W
E
E
E
E E
E
SD
SD
SD
SD
E E
E E
E
E
E
E E
T T T T
T
T T T
T T T T
T
T
T
T
T
T
T
T
TT
SSSS
SS
SS
SS
SS
E E E E
G G
G G
G
G
G
G G
G G G G G
D
12"SS
SD
SD
18"SD
12"SS
D
D
D
SS
E E E
T
FO FO
FO
FO
FO
FO
FO
FO
FO
FO
FO FO
FO FO
23 24 25 26
50 50
50 50 50 50
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
M H
M H
M H
M H
S
S
S
S
TS
TS
TS
TS
TS
TS
TS
TS
TS TS
EV
EV
EV
EV
TRE E
C
C
C
C
C
C
C C
C
C
T
T
T
T
SLSL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
SL
TV
C
24+82.5 (38.5'R);
(N)JUNCTION BOX - LANDSCAPE
(DOUBLE STACK)
24+62.9 (34.9'R);
REMOVE (E)PULL BOX AND
REPLACE WITH (N)JUNCTION BOX - HARDSCAPE
(SINGLE STACK);
RECONNECT (E)2-3"∅ CONDUIT IN/OUT
20+51.0 (33.0'R);
(E)PULL BOX
20+51.0 (33.0'R);
(E)PULL BOX
18+91.6 (9.2'R); AP
19+11.5 (9.7'R); AP
21.2'
4.0'
.0
.0
7.
3'
.2
4.
2'
3.
1'
25+73.0 (15.3'R); AP
18"
60" MIN.
(NOT TO SCALE)
4-3" CONDUIT
TRENCH SECTION IN ROADWAY
4-3" CONDUIT
6"
FIBER OPTIC
WARNING TAPE
SAND BACKFILL
(90% COMPACTION)
3/4" AB BACKFILL
(95% COMPACTION)
AC PAVEMENT SHALL BE
THICKNESS OF (E)AC PAVEMENT
OR 4", WHICHEVER IS GREATER
30"
4"
(NOT TO SCALE)
4-3" CONDUIT
TRENCH SECTION IN SIDEWALK
3/4" AB BACKFILL
(95% COMPACTION)
CONCRETE SHALL BE THICKNESS
OF (E)CONCRETE OR 4",
WHICHEVER IS GREATER
18"
60" MIN.
4-3" CONDUIT
6"
FIBER OPTIC
WARNING TAPE
SAND BACKFILL
(90% COMPACTION)
4"
(NOT TO SCALE)
4-3" CONDUIT
TRENCH SECTION IN LANDSCAPE
NATIVE MATERIAL
(90% COMPACTION)
4" TOP SOIL
(DO NOT COMPACT)
RESTORE LANDSCAPE
TO ORIGINAL CONDITION
18"
60" MIN.
4-3" CONDUIT
6"
FIBER OPTIC
WARNING TAPE
SAND BACKFILL
(90% COMPACTION)
4"
C11 C17
JWF
KH, JQ
KH, JQ, NA
3/20/2026
C
IT
Y O
F W
E S T S
A C R
A M
E N T O
P L A N F
O R
IV
E R
F R
O N T
R
D S
T C
IP
W
AS
HI
NG
TO
N
DI
ST
RI
CT
IN
FR
AS
TR
UC
TU
RE
U
PG
RA
DE
P
RO
JE
CT
IM
P R
O V E M
E N T P
L A N S F
O R
: C A L
IF
O R
N
IA
0 40'20' 80'
DRAWING SCALE
HOR. SCALE:
VERT. SCALE:
SHEET NO. OF
REVIEWER:
DATE:
DRAFTER:
DESIGNER:
DRAWING INFO
CH
EC
KE
D
BY
DA
TE
DRAWING SCALE
RE
VI
SI
ON
D
ES
CR
IP
TIO
N
NO
REY PROJ NO.CIP NO.
SCALE IN FEET
0 40'20' 80'
RIVERFRONT STREET
(SCALED FOR CLARITY)
SHEET LEGEND:
SCHEDULE 80 CONDUITS (ORANGE).
SIZE & QTY PER PLAN
(E)BOW
(E)TBC
PULLBOX (SEE NOTE 2)
C A B
A L D
O N P
K W
Y
G S
T
(E)BOW
(E)TBC
B A L L P A R
K D
R
R/W
(SEE TH
IS SH
EET)
M
A T C H
L
IN
E S
T A
(SEE TH
IS SH
EET)
M
A T C H
L
IN
E S
T A
(S
EE
S H
EE
T
C
M
A T C H
L
IN
E S
T A
3RD STREET
SUTTER HEALTH PARK
SUTTER HEALTH PARK
PARKING LOT
ZIGGURAT
PARKING
(E)BOW
(E)TBC
(E)BOW
(E)TBC
(E)STORM DRAINSD
(E)SANITARY SEWERSS
(E)WATERW
(E)GASG
(E)ELECTRICE
(E)TELEPHONET
(E)COMMUNICATIONSC
RIGHT-OF-WAY
CENTERLINE
PROPERTY LINE
CAPITOL YARDS
APARTMENTS
ZIGGURAT
302-306
(E)PLANTER
AREA
(E)PLANTER
AREA
(E)PLANTER
AREA (E)PLANTER
AREA
(E)PLANTER AREA
(E)PLANTER
AREA
(E)PLANTER
AREA
(E)BOW
(E)TBC
(E)BOW
(E)TBC
R/W
EXISTING(E)
FUTURE(F)
NOTES
1. SPACING BETWEEN PULLBOXES SHALL NOT EXCEED 500 FEET UNLESS
APPROVED BY THE CITY.
2. PULLBOXES SHALL BE CALTRANS NO. 6 (15-1/4"W x 28-1/4"L x 12"D) PER
CALTRANS STD PLAN ES-8A WITH SIPRA LOCKJAW LID. LID SHALL BE
INSCRIBED WITH "COWS INTERCONNECT". SEE INSTALLATION DETAIL,
SHT C12.
3. JUNCTION BOXES SHALL BE CHRISTY P48 TELEPHONE BOX (30-1/4"W x 48-1/4"L x 14"D) WITH SIPRA LOCKJAW LID. LID SHALL BE INSCRIBED WITH
"COWS INTERCONNECT". SINGLE STACK SHALL BE ONE CHRISTY P48
BOX. DOUBLE STACK SHALL BE ONE CHRISTY P48 BOX WITH ONE P48
EXTENSION (10"DEEP). SEE INSTALLATION DETAIL, SHT C12.
4. CONDUIT TO BE HDPE SCHEDULE 80 ELECTRICAL.
5. THE BEND RADIUS OF CONDUITS MUST BE SIX TIMES THE INSIDE
DIAMETER OF THE CONDUIT OR GREATER.
6. CONSTRUCT TRENCH FOR CONDUITS PER DETAIL ON SHT C11.
7. PROVIDE CONTINUOUS NON-METALLIC PULL TAPE (MIN. 3/8" DIA., 2,500 LB
TENSILE) IN EACH CONDUIT; SECURE AND TAG AT ALL ACCESS POINTS.
TAG AT ACCESS POINTS SHALL INDICATE DATE OF CONDUIT INSTALL
AND CONTRACTOR NAME.
8. CONTRACTOR SHALL MARK ALL PROPOSED UTILITY BOX LOCATIONS
ONCE USA MARKINGS ARE PAINTED ON THE GROUND. CONTRACTOR
SHALL COORDINATE WITH CITY INSPECTION PRIOR TO ANY
CONSTRUCTION WORK BEING PERFORMED TO AVOID UTILITY
CONFLICTS.
(E)TBC
(E)TBC
(E)BOW
JUNCTION BOX (SEE NOTE 3)
12" STEEL CASING TO BE INSTALLED PER
UPRR PIPELINE INSTALLATION
ENGINEERING SPECIFICATIONS AND
DETAIL ON SHEET 12. LIMITS OF CASING
PER PLAN.
(E)2-4" INTERCONNECT
CONDUIT
BID ALT 1: (N)2 - 3"Ø CONDUIT
LABEL 1 CONDUIT "SPARE #1"
LABEL OTHER CONDUIT "SPARE #2"
(N)2 - 3"Ø CONDUIT
LABEL 1 CONDUIT "INTERCONNECT"
LABEL OTHER CONDUIT "SPARE #1"
BID ALT 1:
BID ALT 1:
(E)N48 BOX
INTERCONNECT VAULT
BID ALT 1: 2 - 3"Ø CONDUIT
LABEL 1 CONDUIT "SPARE #1"
LABEL OTHER CONDUIT "SPARE #2"
BID ALT 1: 2 - 3"Ø CONDUIT
LABEL 1 CONDUIT "SPARE #1"
LABEL OTHER CONDUIT "SPARE #2"
BID ALT 1: 2 - 3"Ø CONDUIT
LABEL 1 CONDUIT "SPARE #1"
LABEL OTHER CONDUIT "SPARE #2"
(N)2 - 3"Ø CONDUIT
LABEL 2 CONDUIT "INTERCONNECT"
LABEL OTHER CONDUIT "SPARE #1"
(E)2-3"Ø INTERCONNECT
CONDUIT
(E)2-4"Ø CONDUIT
SCHEDULE 80 CONDUITS (ORANGE) FOR
BID ALT 1. SIZE & QTY PER PLAN
(E)2-4" INTERCONNECT
CONDIUT
(E)1-3" INTERCONNECT
CONDUIT
BID ALT 1:
(N)2-3"Ø CONDUIT IN/OUT
(N)2-3"Ø CONDUIT OUT
(N)2-3"Ø CONDUIT IN
BID ALT 1:
(N)2-3"Ø CONDUIT IN/OUT
(E)2-3"Ø INTERCONNECT
CONDUITS
(E)2-4"Ø CONDUIT IN/OUT
(E)2-4"Ø CONDUIT…