Sol_P17PS01105_Amd_000002.pdf

PDF 87 KB Posted

Attached to
General construction of a new community water conn
Solicitation number
P17PS01105
Issued by

About this file

P17PS01105

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(x)

P17PS01105

x x

1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT

THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

x

PMM

St Louis MO 63102 11 North 4th Street NPS, MWR - Missouri MABO

06/23/2017000002

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

FACILITY CODE CODE

10B. DATED (SEE ITEM 13)

10A. MODIFICATION OF CONTRACT/ORDER NO.

9B. DATED (SEE ITEM 11)

9A. AMENDMENT OF SOLICITATION NO.

CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)

7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY

PAGE OF PAGES

4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)

1. CONTRACT ID CODE

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

06/02/2017

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority) appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

E. IMPORTANT: Contractor is not, is required to sign this document and return __________________ copies to the issuing office.

ORDER NO. IN ITEM 10A.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

If you have any questions concerning this solicitation, contact Neal Hause at 314-655-1609 or email at neal_hause@nps.gov.

Legacy Doc #: NPS

This amendment is issued to add the following information to the solicitation:

Existing Well depth, well diameter and casing depth. The well is 1600 feet deep. The casing size is 8-inch and the casing extends down in the well 300 feet. The pump and drop pipe are set at 300 feet. Changed demolition spec 02224. See attachment 10 existing water tank and existing pump house drawing scan.

Continued ...

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED

(Signature of person authorized to sign) (Signature of Contracting Officer)

Neal Hause

STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA

FAR (48 CFR) 53.243

NSN 7540-01-152-8070

Previous edition unusable

Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .

ITEM NO. SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

NAME OF OFFEROR OR CONTRACTOR

2 3

CONTINUATION SHEET

REFERENCE NO. OF DOCUMENT BEING CONTINUED PAGE OF

(A) (B) (C) (D) (E) (F)

P17PS01105/000002

Add 3-1000 gallon fire tanks to demo spec: (3) three one thousand gallon buried water storage tanks for the existing Visitor Center fire protection system shall have the covers removed and the fiberglass tanks filled with sand. Top soil and seed the over the abandoned tanks.

Changed spec 02224.

Add Attachment 11: PERI "Special Seeding

Requirements". Changed spec 02921 Seeding, Fertilizer and Mulching.

Added Tree Removal: "Minimal tree removal is expected during the course of this contract.

However, if a tree needs to be removed, contact the Park Superintendent for NPS approval prior to removal. All compliance documentation following appropriate NPS guidance and policy is required".

Changed spec 02320 trenching, backfill, boring, surfacing.

Added location of the pipeline: "The location of the proposed water main will be generally located

15 feet to the south of the north edge (tree line) of the abandoned road right of way line".

Changed spec 02320 trenching, backfill, boring surfacing.

Added placing a meter pit outside the VC on the new service line:

Note: The 1 ½ inch water service line for the

Visitor Center shall incorporate a meter box set outside the Visitor Center and be supplied with a shut off valve and house a one (1) 1-inch ultrasonic meter with riser type copper setter.

Changed spec 02511 Water Service Line.

Add take out old piping, add RPZ, disconnect fire pumps and piping. Also tie existing alarm panel into new service line system for fire protection in the Visitor Center:

Note: The 4-inch Fire service line shall be tied into the existing piping tree in the Visitor

Center. This new connection shall incorporate a new 2 ½ inch RPZ valve and necessary pipe fittings to tie into the existing fire piping tree. The existing fire pumps and unnecessary piping shall be removed. The existing fire pump control panels shall be taken out of service.

Continued ...

NSN 7540-01-152-8067 OPTIONAL FORM 336 (4-86)

Sponsored by GSA

FAR (48 CFR) 53.110

ITEM NO. SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

NAME OF OFFEROR OR CONTRACTOR

3 3

CONTINUATION SHEET

REFERENCE NO. OF DOCUMENT BEING CONTINUED PAGE OF

(A) (B) (C) (D) (E) (F)

P17PS01105/000002

The existing alarm panel shall incorporate the new service line and made functional. The new fire service line shall be fully functional and meet NFPA requirements. Changed spec 02511 water service line.

Add the revised set of Specifications as

Attachment 12

Add the revised set of Drawings as Attachment 13.