SIDEWALL FLASHING WITH TWO-PIECE COUNTERFLASHING
SLATE
SHEET-METAL STEP FLASHING AT
EACH COURSE
UNDERLAYMENT
TURNED UP WALL
MAINTAIN 1"
ABOVE ROOF
SURFACE
TWO-PIECE SHEET-METAL
COUNTERFLASHING
OVERLAP STEP FLASHING MIN. 2"
BUILDING WRAP OVERLAP
COUNTERFLASHING MIN. 2"
WALL SIDING/CLADDING
NOT SHOWN FOR CLARITY
APPROPRIATE
FASTENERS
3"
MIN
SLATE-13
REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ADDITIONAL INFORMATION.
FOR SECUREMENT AND JOINERY OPTIONS FOR SHEET METAL AND COUNTERFLASHING OPTIONS, REFER TO THE NRCA ROOFING MANUAL:
ARCHITECTURAL METAL FLASHING, CONDENSATION CONTROL AND REROOFING.
415The NRCA Roofing Manual: Steep-slope Roof Systems—2013 Slate Roof Systems | Chapter 6—Construction Details
N
R C A R ep ri nt p er m is si on g ra nt ed t o
Er ic
F or d at
C an e R iv er C re ol e N
H P.
N o fu rt he r re pr od uc tio ns a ut ho ri ze d.
M ar
6, 5.
SIDEWALL FLASHING WITH ONE-PIECE COUNTERFLASHING
SHEET-METAL STEP FLASHING AT
EACH COURSE
UNDERLAYMENT
TURNED UP WALL
MAINTAIN 1" ABOVE
ROOF SURFACE
ONE-PIECE SHEET-METAL
COUNTERFLASHING
OVERLAP STEP FLASHING MIN. 2"
BUILDING WRAP OVERLAP
COUNTERFLASHING MIN. 2"
WALL SIDING/CLADDING
NOT SHOWN FOR CLARITY
APPROPRIATE
FASTENERS
3"
MIN
WALL SIDING/CLADDING
OVERLAP STEP FLASHING
MIN. 2"
OPTION
SLATE-13A
MAINTAIN 1" ABOVE
ROOF SURFACE
REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ADDITIONAL INFORMATION.
FOR SECUREMENT AND JOINERY OPTIONS FOR SHEET METAL AND COUNTERFLASHING OPTIONS, REFER TO THE NRCA ROOFING MANUAL:
ARCHITECTURAL METAL FLASHING, CONDENSATION CONTROL AND REROOFING.
416 The NRCA Roofing Manual: Steep-slope Roof Systems—2013 Slate Roof Systems | Chapter 6—Construction Details
N
R C A R ep ri nt p er m is si on g ra nt ed t o
Er ic
F or d at
C an e R iv er C re ol e N
H P.
N o fu rt he r re pr od uc tio ns a ut ho ri ze d.
M ar
6, EXPANSION JOINT
SLATE-14
REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ADDITIONAL INFORMATION.
FOR SECUREMENT AND JOINERY OPTIONS FOR SHEET METAL AND COUNTERFLASHING OPTIONS, REFER TO THE NRCA ROOFING MANUAL:
ARCHITECTURAL METAL FLASHING, CONDENSATION CONTROL AND REROOFING.
FLASHING REQUIREMENTS ARE TYPICAL FOR BOTH SIDES OF EXPANSION JOINT. SEE DETAIL SLATE-13 FOR ADDITIONAL INFORMATION.
SHEET-METAL STEP
FLASHING AT EACH
COURSE
SLATE
UNDERLAYMENT
SHEET-METAL EXPANSION JOINT
COVER WITH T-TYPE CLEAT
SEE NOTE 2. OVERLAP STEP
FLASHING MIN. 2"
FLEXIBLE
WEATHERPROOF
MEMBRANE
CLOSURE
FLEXIBLE LINER
WITH COMPRESSIBLE
INSULATION
417The NRCA Roofing Manual: Steep-slope Roof Systems—2013 Slate Roof Systems | Chapter 6—Construction Details
N
R C A R ep ri nt p er m is si on g ra nt ed t o
Er ic
F or d at
C an e R iv er C re ol e N
H P.
N o fu rt he r re pr od uc tio ns a ut ho ri ze d.
M ar
6, VENT PIPE PENETRATION
FIELD UNDERLAYMENT AND ROOF
DECK NOT SHOWN FOR CLARITY
REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ADDITIONAL INFORMATION.
OPTIONAL: SEALANT
UNDER SLATE
SLATE-15
PIPE PENETRATION FLASHING
UNDERLAYMENT
UNDERLAYMENT
OVER FLASHING
SOFT-METAL FLASHING SLEEVE
ROLL INTO PIPE APPROX. 1"
OPTIONAL:
SEALANT
LAP UNDERLAYMENT OVER FLASHING
418 The NRCA Roofing Manual: Steep-slope Roof Systems—2013 Slate Roof Systems | Chapter 6—Construction Details
N
R C A R ep ri nt p er m is si on g ra nt ed t o
Er ic
F or d at
C an e R iv er C re ol e N
H P.
N o fu rt he r re pr od uc tio ns a ut ho ri ze d.
M ar
6, CHIMNEY WITH CRICKET FLASHING
SHEET-METAL
COUNTERFLASHING
SHEET-METAL
APRON FLASHING
WITH HEMMED EDGE
SLATE
SOLDER OR
SEAL CORNERS
SHEET-METAL
STEP FLASHING
UNDERLAYMENT
TURNED UP WALL
SHEET-METAL COUNTERFLASHING
SHEET-METAL CRICKET
FLASHING WITH HEMMED
EDGE SOLDER OR
SEAL CORNERS
STEP FLASHING BOTH
SIDES OF CHIMNEY
CRICKET FLASHING AT MASONRY CHIMNEY
APRON FLASHING AT MASONRY CHIMNEY
3" MIN.
SLATE-16
REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ADDITIONAL INFORMATION.
FOR SECUREMENT AND JOINERY OPTIONS FOR SHEET METAL AND COUNTERFLASHING OPTIONS, REFER TO THE NRCA ROOFING MANUAL:
ARCHITECTURAL METAL FLASHING, CONDENSATION CONTROL AND REROOFING.
THIS DETAIL APPLIES TO CHIMNEYS THAT ARE WIDER THAN 24 INCHES.
LAP UNDERLAYMENT
OVER FLASHING
419The NRCA Roofing Manual: Steep-slope Roof Systems—2013 Slate Roof Systems | Chapter 6—Construction Details
N
R C A R ep ri nt p er m is si on g ra nt ed t o
Er ic
F or d at
C an e R iv er C re ol e N
H P.
N o fu rt he r re pr od uc tio ns a ut ho ri ze d.
M ar
6, 5.
CRICKET
ARE WIDER THAN 24 INCHES.
CHIMNEY WITH BACKER FLASHING
(24 INCHES WIDE OR LESS)
SHEET-METAL
COUNTERFLASHING
SHEET-METAL BACKER
FLASHING WITH HEMMED
EDGE SOLDER OR SEAL
CORNERS
STEP
FLASHING
BOTH SIDES
OF CHIMNEY
BACKER FLASHING AT MASONRY CHIMNEY
APRON FLASHING AT MASONRY CHIMNEY
SLATE-17
SHEET-METAL
APRON FLASHING
WITH HEMMED EDGE
SHEET-METAL
COUNTERFLASHING
SOLDER OR
SEAL CORNERS
SLATE
UNDERLAYMENT
TURNED UP WALL
SHEET-METAL
STEP FLASHING
REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ADDITIONAL INFORMATION.
FOR SECUREMENT AND JOINERY OPTIONS FOR SHEET METAL AND COUNTERFLASHING OPTIONS, REFER TO THE NRCA ROOFING MANUAL:
ARCHITECTURAL METAL FLASHING, CONDENSATION CONTROL AND REROOFING.
THIS DETAIL APPLIES TO CHIMNEYS THAT ARE 24 INCHES WIDE OR LESS.
LAP UNDERLAYMENT
OVER FLASHING
420 The NRCA Roofing Manual: Steep-slope Roof Systems—2013 Slate Roof Systems | Chapter 6—Construction Details
N
R C A R ep ri nt p er m is si on g ra nt ed t o
Er ic
F or d at
C an e R iv er C re ol e N
H P.
N o fu rt he r re pr od uc tio ns a ut ho ri ze d.
M ar
6, 421The NRCA Roofing Manual: Steep-slope Roof Systems—2013 Slate Roof Systems | Chapter 6—Construction Details
CURB-MOUNTED SKYLIGHT
BACKER FLASHING
SLATE
SKYLIGHT
APRON FLASHING
TURN UP UNDERLAYMENT
AT CURB
SKYLIGHT FLANGE
OVERLAP STEP
FLASHING APPROX. 2"
OR INSTALL
COUNTERFLASHING
SEALANT
STEP FLASHING
INSTALL CRICKET AT SKYLIGHTS THAT ARE WIDER THAN 24 INCHES.
REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ADDITIONAL INFORMATION.
WHERE DEEMED NECESSARY, HOLD SLATE UP ONE COURSE DEPENDING ON ANTICIPATED DEBRIS AND/OR SNOW ACCUMULATION.
SLATE-18
LAP UNDERLAYMENT
OVER FLASHING
N
R C A R ep ri nt p er m is si on g ra nt ed t o
Er ic
F or d at
C an e R iv er C re ol e N
H P.
N o fu rt he r re pr od uc tio ns a ut ho ri ze d.
M ar
6, CRICKET ARE WIDER THAN 24 INCHES.
422 The NRCA Roofing Manual: Steep-slope Roof Systems—2013 Slate Roof Systems | Chapter 6—Construction Details
STEEP- TO LOW-SLOPE ROOF SYSTEM TRANSITION
SLATE
UNDERLAYMENT
ROOF DECK
ROOF SYSTEM EXTENDED
ABOVE TRANSITION
SLATE HELD BACK
10" MIN.
COMPATIBILITY OF UNDERLAYMENT AND LOW-SLOPE MEMBRANE SHOULD BE CONSIDERED.
REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ADDITIONAL INFORMATION.
STARTER/FIRST COURSE
SHALL COVER BASE FLASHING
SLATE-19©