JEME_Bid_Documents_04-16-15.pdf
PDF 17 MB Posted
- Attached to
- Jefferson Memorial Safety Netting Federal contract opportunity
- Solicitation number
- P15PS01309
About this file
specs/drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_P15PS01309_Amd_000002.pdf | ||
| Sol_P15PS01309_Amd_000001.pdf | ||
| davis_bacon_building_wages_new.pdf | ||
| DebrisNetting_Bid_Form_03-20-15.xls | XLS spreadsheet | |
| evaluation_criteria_jefferson_memorial.rtf | RTF text file | |
| Jefferson_Memorial_Debris_netting_SOW_04-16-15.pdf | ||
| construction_clauses.rtf | RTF text file | |
| construction_clause_netting_new_over_30k.rtf | RTF text file | |
| Sol_P15PS01309.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GSPublisherEngine 304.60.62.100
SHEET
OF
G-001
J e f f e r s o n
M e m o r i a l
P o r t i c o
C e i l i n g
N e t t i n g
S y s t e m
W e s t
P o t o m a c
P a r k
S
W
W a s h i n g t o n
D
C U
S A
CONSULTANT/FIRM:
DESIGNED BY:
DRAWN BY:
CHK'D BY:
DWG NO.:
000000
JJC
JJC
SK
DATE:
03-20-15
0-000
DESCRIPTION
MARK SHEET
03/20/15
DATE
JJC
INITIAL
Division Review
RELEASE DATE / REVISION DATE:
S H
E E
T
I T
L E
SEAL:
03/30/15Div. Chief Review JJC
Written dimensions on these drawings shall have precedence over scale dimensions.
Contractor shall verify and be responsible for all dimensions and conditions on the job.
This office must be notified of any variations from the dimensions and conditions.
United States Department of the Interior
National Park Service
National Mall and Memorial Parks
Divison of Professional Services
C o v e r
S h e e t
G-001
G-002
AS-101
A-101
A-102
A-201
A-301
Cover Sheet
Notes, Materials, and Abbrev.
Mobilization Plan
Main Floor Barricade Plan
Reflected Ceiling Plan
Exterior Elevations
Portico-Netting Sections
United States Department of the Interior
National Park Service
Jefferson Memorial Portico Ceiling Netting System
National Mall and Memorial Parks
Washington DC 20024
Vicinity Map
Drawing Index
T I D A L B A S I N
P O T O M A C R I V E R
W A S H I N G T O N C H A N N E L
PROJECT SITE
OF
G-002
J e f f e r s o n
M e m o r i a l
P o r t i c o
C e i l i n g
N e t t i n g
S y s t e m
W e s t
P o t o m a c
P a r k
S
W
W a s h i n g t o n
D
C U
CONSULTANT/FIRM:
DESIGNED BY:
DRAWN BY:
CHK'D BY:
DWG NO.:
000000
JJC
JJC
SK
DATE:
03-20-15
0-000
DESCRIPTION
MARK SHEET
03/20/15
DATE
JJC
INITIAL
Division Review
RELEASE DATE / REVISION DATE:
S H
E
T
L E
SEAL:
03/30/15Div. Chief Review JJC
Written dimensions on these drawings shall have precedence over scale dimensions.
Contractor shall verify and be responsible for all dimensions and conditions on the job.
This office must be notified of any variations from the dimensions and conditions.
United States Department of the Interior
National Park Service
N t e s
M a t e r i a l s a n d
A b b r e v
Room Name
Room # Finish
A
A
A-301
A-201
A1-1
DETAIL
SCALE: 1/4" = 1'-0"
A-601
04 A-100
SHEET NO.
SCALE
PARTITION TYPE
KEY
NOTES
EQUIPMENT
NO.
WINDOW
REFERENCE
ROOM NO./
FINISH
INFORMATION
REVISION
REFERENCE
DOOR
REFERENCE
DETAIL NO.
SHEET NO.
ELEVATION NO.
NAME OF DRAWING
SHEET NO.
SECTION NO.
SHEET NO.
REFERENCE NO.
SYMBOLS
CORR CORRIDOR
ATTEN. ATTENUATION
@ AT
ARCH ARCHITECT (URAL)
APPROX APPROXIMATE (LY)
ALUM ALUMINUM
A.F.F. ABOVE FINISHED FLOOR
ACST ACOUSTIC
CLR CONTINUE OR
CONTNUOUS
EXT EXTERIOR
BLDG BUILDING
BOT BOTTOM
BD BOARD
BLKG BLOCKING
BLK BLOCK
BETW BETWEEN
BM BEAM
BSMT BASEMENT
BALC BALCONY
DWG DRAWING
DIA OR Ø DIAMETER
CRS COURSES
C TO C CENTER TO CENTER
CL CENTERLINE
CLG CEILING
CONN CONNECTION
C.M.U. CONCRETE
MANSONRY UNIT
CONC CONCETE
COL. COLUMN
C.W. COLD WATER
CLR CLEAR (ANCE)
C CHANNEL
C.T. CERAMIC TILE
DET DETAIL
o DEGREE
DR DOOR
DIM DIMENSION
DN DOWN
EXIST EXISTING
ENGR ENGINEER
EQUIP EQUIPMENT
EMER EMERGENCY
ELEV ELEVATION (VIEW)
ELEV ELEVATOR
EL ELEVATION (GRADE)
ELEC ELECTRIC (AL)
E.W.C. ELECTRIC WATER COOLER
E EAST
EA EACH
FLR FLOOR
FLSHG FLASHING
F.H. FIRE HYDRANT
F.E.C. FIRE EXTINGUISHER
CABINET
F.E. FIRE EXTINGUISHER
FIN.FLR FINISH (ED) FLOOR
FIN FINISH
FT OR (') FOOT (FEET)
WD WOOD
INSUL INSULATION
I.D. INSIDE DIMENSION
(") OR IN INCH
H.W. HOT WATER
H.B. HOSE BIBB
H.M. HOLLOW METAL
H.P.T. HIGH POINT
HT HEIGHT
HDW HARDWARE
J.C. OR JAN. CL. JANITOR'S CLOSET
Q.T. QUARRY TILE
LVR LOUVER
LAV LAVATORY
LAMIN. OR LAM. LAMINATE
LAD LADDER
MTG MOUNTING
MISC MISCELLANEOUS
MIN MINIMUM
MEL METAL
M MEN
MEM MEMBRANE
MECH MECHANICAL
MAX MAXIMUM
MACH.RM. MACHINE ROOM
MAT'L MATERIAL
M.O. MANSONRY OPENING
MAS MASONRY
MH MANHOLE
PCC PORTLAND CEMENT
CONCRETE
NO. OR # NUMBER
N.I.C. NOT IN CONTACT
N NORTH
NOM NOMINAL
OFF OFFICE
O.D. OUTSIDE DIAMETER
O.H. OPPOSITE HAND
OPNG OPENING
O.C. ON CENTER
PT POINT
PLAST PLASTIC
PL PLATE (STEEL)
PLAS PLASTER
PARTN PARTITION
PARK'G PARKING
P.T.D. PAPER
TOWEL DISPENSER
PNL PANEL
PR PAIR
PTD PAINTED
PRCST PRECAST
PROT. BD. PROTECTION BOARD
P.L. PROPERTY LINE
PROP PROPERTY
GYP GYPSUM
GRAN GRANITE (ED) (ING)
GLAZ GLAZE
GL GLASS
GA GAUGE
SUSP.CLG. SUSPENDING
CEILING
SUSP SUSPENDING
STRUCT. STRUCTURAL
REINF REINFORCE (ING)
R RADIUS
RM ROOM
RFG ROOFING
R.D. ROOF DRAIN
R ROOF
REV REVISION
REQ'D REQUIRED
SAN SANITARY
SP STANDPIPE
SHTNG SHEATING
SEC SECTION
SLNT SEALANT
SCH. OR SCHED.SCHEDULE
ST. STL. STAINLESS STEEL
SQ. IN. SQUARE INCH
SQ. FT. SQUARE FEET
SQ SQUARE
SPEC SPECIFICATION
S SOUTH
SIM SIMILIAR
SHT SHEET
U.L. UNDERWRITER'S
LABORATORY
TYP TYPICAL
T TREAD
T.W. TOP OF WALL
T.C. TOP OF CURB
T TOILET
THRESLD
THRESHOLD
THK THICK (NESS)
TEMPR TEMPERED
TELE OR TEL TELEPHONE
UTIL UTILITY
V.A.T. VINYL ASBESTOS
TILE
VERT VERTICAL
VENT VENTILATE (ION)
VAR VARIABLE
VEST VESTIBLE
W/ WITH
W WEST
W.W.M. WELDED WIRE
MESH
W.S. WEATHER-
STRIPPING
WP WATERPROOF(ING)
W.C. WATER CLOSET
W. MH. WATER MANHOLE
W WOMEN
W/OUT WITHOUT
ABBREVIATIONS
CAST STONE
INSULATED METAL
PANELS
FLASHING & METAL
IN SMALL SECTION
EXPANSION BOARD
FIRE PROOFING
SPRAYED
GLAZING GYPSUM SHEATHING
OR WALL BOARD
PROTECTION BOARD
CONCRETE MASONRY
UNIT-GROUND FACE
ALUMINUM
GRANITE IN SECTION
AND ELEVATION
STAINLESS STEEL
EARTH
TILE: CERAMIC AND
QUARRY
GRAVEL
BRICK
CONCRETE MASONRY
UNIT (BLOCK)
BATT INSULATION
PLASTER, CEMENT &
SPRAY-ON
INSULATION
RIGID OR SEMI
INSULATION
POURED IN PLACE
CONCRETE
PRECAST CONCRETE
MARBLE
STEEL
WOOD IN
ELEVATION
DISCONTINUOUS
WOOD BLOCKING
PLYWOOD
CONTINUOUS WOOD
BLOCKING AND FURRING
FINISHED WOOD
STONE
MATERIALS
SHEET NO.
ELEVATION NO.
LIGHT FIXTURE
GENERAL NOTES
1. All work is to be done in conformance with all applicable codes and regulations.
2. Contractor shall conform to all O.S.H.A. requirements.
3. Contractor shall provide barricades and protective safely devices as required by codes, ordinances and current O.S.H.A. regulations.
4. Contractor to visit site and completely familiarize existing conditions prior to execution of any construction, contract Architect prior to execution any work in question.
5. Check all dimensions on job and fully verify prior to execution. Failure to do so will be at no additional expense to the owner. All work to be fully executed in accordance with all governing codes and regulation. All elevations given are approximate and are given for relational purposes. Contractor shall establish exact levels prior to start of work and notify Architect of any significant discrepancies.
6. Demolition: To be provided by Contractor as required. Completely remove all trash from site.
7. Utilities: Coordinate and provide as per drawings.
8. Contractor shall submit shop drawings/vendor data submittal schedule to Architect for review and approval within thirty (30) days from commencement of work. Submit four (4) copies to Architect.
Allow five (5) working days for review. No construction shall proceed until the approval of these drawings. All trades shall be reviewed by the Architect at the same time. Contractor shall provide manufacture's specification, installation, instruction, shop drawings and samples for review and approval of all materials and methods to be used prior to ordering or proceeding with the work.
Contractor shall follow procedures. If these are contrary to the contract documents, contractor shall notify Architect, in writing immediately to resolved discrepancies prior to proceeding. All materials submitted shall be transmitted using National Park Service CM-16 transmittal. See scope of work for
CM-16 form.
9. Contractor shall not scale drawing, and discrepancies between existing conditions and drawings shall be reported to Architect for clarification prior to commencement of work. In the event of conflict between data shown on drawing and data shown on specifications, the specifications shall govern.
Dimensions noted on drawings shall take precedence scale over drawings detail drawings take precedence over drawings on smaller scale. Should the contractor at any time discover an error in a drawing or specification or a discrepancy or variation between dimensions or other information, he should not proceed with the work affected until clarification is made.
10. Contractor shall be responsible for the inclusion of all work necessary for complete installation whether such work is or is not indicated.
11. All manufactured items shall be installed in strict accordance with the manufacturer's written instructions.
12. Warranties, guarantees and manufacture's instructions on equipment furnished and installed by the
Contractor shall be given to the Owner.
13. Contractor shall provide protection on a daily basis for all work that comes in contact with the existing
Memorial.
14. The fire rating of all existing rated construction shall be maintained.
15. All wood products used shall be Wolmanized Preservative protected, treated in accordance with
Copper Azole treatment for use Catagory 4A.
16. In areas where the drawings do not address methodology, the Contractor shall be bound to perform in strict compliance with manufacturer's specifications and recommendations.
17. In the event certain features of the construction are not fully shown on the drawing, their construction shall be of the same character as for similar conditions that are shown or noted.
18. The Architect will not be responsible for and will not have control over construction means, methods, techniques, sequences, procedures, or for safety precautions and programs in connection with the work, and will not be responsible for the failure of the client or his contractors, subcontractors, or anyone performing any of the work, to carry out the work in accordance with the approved contract documents.
19. All Concrete details and construction are to comply with latest A.C.I. Code and local codes, if any work exists in project.
20. Approval of these drawings by Governing Authorities does not release the Contractor from complying with all applicable codes and standards.
21. The General Contractor shall furnish and install portable fire extinguishers of the correct capacity and rating as requires by N.F.P.A. Pamphlet #10 and the National Park Service.
22. Fire extinguisher (on floor plan) - indicates general location of extinguishers, General Contractor to verify exact placement with Owner and Fire Marshal prior to installation.
23. All notes on this drawing apply for the entire project whether or not repeated on other drawings.
24. Where new work is to be done, care shall be taken to protect all existing adjacent surfaces and areas from damage. Any areas damaged during construction or demolition shall be restored to their original condition at no additional cost. This applies particularly to adjacent tenant spaces, roof, and other exterior areas and surfaces.
25. The Architect and Owner will consider formal requests from the Contractor for substitution of products, materials or manufacturers. These requests shall accompany but not included in the base bid on the specified bid due date. Submit five copies of request for substitution.
26. Only new, first class material will be used (except as noted). Rejected items shall be removed immediately from the work and replaced with items of the quality specified. Failure to remove rejected materials and equipment shall not relieve the contractor from the responsibility for quality and character of items used nor from any other obligation imposed on him by the contract.
27. No combustible materials are permitted above ceiling.
28. The General Contractor shall bear full responsibility and cost for the following:
A. Permit, Licenses, Inspections and Fees (all impact fees).
B. Temporary power and utilities.
C. Trash removal.
D. Liabilities and workmen's compensation insurance, etc.
E. And other items indicated in specifications.
29. Removal, disposal, alteration and relocation of existing mechanical and electrical equipment, conduit, pipes and ducts is included in the Work and shall be coordinated with COR.
30. The contract documents include the working drawings, agenda, modifications, general conditions of the construction and specifications.
31. The contract documents are instruments of service and shall remain the property of the National Park
Service whether the project for which they are prepared is executed or not. The contract documents shall not be used by the contractor for other projects or extensions to the project, nor are they to be modified in any manner whatsoever except by agreement in writing with the COR. "Furnish"î means supply only for others to put in place.
32. ìProvideî means furnish and install, complete and in place.
33. ìSimilarî means comparable characteristics for condition noted. Contractor to verify dimension and orientation.
34. ìTypicalî means identical for conditions noted.
35. Information on these drawings in based on existing documents and limited measurements and may require adjustment or modification in cased where changes are necessary. These drawings shall be used to show design intent only.
36. Horizontal dimensions indicated are to/from finished face of construction, except as noted.
37. Vertical are from top of floor slab, except where noted to be from above finished floor (AFF)
38. Dimensions are not adjustable without approval of architect unless noted ( ± ).
39. The finish work shall be firm, well anchored, in true alignment, plumb, level, with smooth, clean uniform appearance without waves, distortions, holes, marks, cracks, stain, or discoloration. Joints shall be close fitting, neat and well scribed, the finish shall not present hazardous, unsafe corners. All work shall have the provisions for expansion, contraction and shrinkage as necessary to prevent cracks, buckling and warping due to temperature and humidity conditions.
40. Cut and fit components for alterations of existing work and installation of new work. Patch disturbed areas to match adjacent materials and finishes.
41. All new work shall match in type and finish and existing work already installed noted otherwise.
42. Make all necessary provisions for items to be furnished or installed by NPS. Provide protection for these provisions until completion of the projects. General contractor to coordinate N.I.C. items with appropriate trades, to tenants independent contractors.
43. General contractor shall review the base building contract documents or existing base building conditions and shall comply with all base requirements, standards, and design.
44. General Contractor shall be responsible for checking contract documents, field conditions and dimension for accuracy and confirming that work is buildable as shown before proceeding with construction. Clarification regarding any conflicts shall be achieved prior to related work being started
51. General Contractor and subcontractor shall coordinate the layout and exact location of all joints/connections/anchors, etc. with Architects in the field before proceeding with construction.
52. General Contractor is responsible for and shall provide protection for any and all existing finishes of the
Memorial.
53. Exercise extreme care and precaution during construction of the work to minimize disturbance to the operation of the Memorial and their occupants, property, public thoroughfares, etc. Contractor shall take precautions and be responsible for the safety of all building occupants from construction procedures.
54. Within five (5) days from contract date, prepare and submit and estimated progress schedule for the work with sub-schedules or related activities which may affect the progress.
55. Attachments, connections or fastening of any nature are to be properly secured in conformance with best practice and the contractor is responsible for improving them accordingly and to these conditions.
The drawings show only special conditions to assist contractor they do not illustrate every such detail.
56. The contractor shall continuously check architectural and structural clearances for accessibility of equipment and mechanical and electrical systems. No allowance of any kind will be made for the contractor's negligence to foresee means of installing equipment into position inside structure
57. Abbreviation used in referring to standards that apply to the work include but are not necessarily limited to the following:
American Society of Testing Materials (ASTM)
American Institute of Steel Construction (AISC)
American Welding Society (AWS)
American Concrete Institute (ACI) TO
American National Standard Institute (ANSI)
Architectural Aluminum Manufacturer s Association (AAMA)
Aluminum Association (AA)
Concrete Reinforcing Steel Institute (CRSI)HED TO
National Association of Architectural Metal Manufacturers (NAME)
National Fire Protection Association (NFPA)
National Woodwork Manufacturer s Association (WMA)
Woodwork Institute of America (WIA)
Architectural Woodwork Institute (AWI)
58. Perform all cutting and patching in a neat and workmanlike manner. Any existing finishes disturbed or damaged during the course of the work shall be repaired to match the existing in kind and finish.
59. No work defective in construction or quality or deficient in any requirements of drawings and specifications will be acceptable in consequence of owner's or architect's failure to discover or to point out defects or deficiencies during construction, nor will presence of inspectors on work relieve contractor from responsibility for securing quality and progress or work as required by contract.
Defective work revealed within required time guarantees shall be replaced by work conforming with intent of contract. No payments, whether partial or final, shall be construed as an acceptance of defective work or improper materials.
60. Material and workmanship specified by reference to number symbol, to title of a specification such as commercial standard, federal specifications, trade association standard, or other similar standard, shall comply with requirements in latest edition or revision thereof and with any amendments or supplements thereto in effect or date or origin of this project's contract documents. Such standards, except as though printed in contract documents.
61. Contractor shall wave ìcommon practiceî and ìcommon usageî as construction criteria wherever detail and contract documents or governing codes, ordinance, etc. require greater quantity or better quality than common practice or common usage would require.
62. Contractor shall order and schedule delivery of material in ample time to avoid delays in construction.
If an item is found to be unavailable, contractor shall notify architect immediately to allow architect a reasonable amount of time to select a suitable substitute.
63. If at any time before commencement of work, or during progress thereof, contractor's method, equipment or appliances are inefficient or inappropriate for securing quality of work or rate of progress intended by contract documents, owners may order contractor to improve their quality or increase their efficiency. This will not relieve contractor or his sureties from their obligation to secure quality of work and rate or progress specified in contract.
64. Place all studs, ceiling furring and framing members as required to avoid interference with location of casework, recessed lighting fixture, piping, ductwork and similar items.
65. With reference to ceiling, contractor shall coordinate with all trades involved and prepare composite shop drawings to insure clearances for fixtures, ducts, ceiling, etc. necessary to maintain the specified finish ceiling height above the finish floor as noted on the drawing. Clarify conflict with the Architect.
66. The COR will exercise sole authority for determining conformance of material, equipment and system with the intent of the design, review and acceptance of all items proposed by the contractor for incorporation into its work will be made by Architects. This function will apply both to contract as initially signed and to the changes to contract by modification during progress and work.
67. Reference to makes, brand, models, etc. is to establish type and quality desired, substitution of acceptance equals will not be permitted unless specifically noted otherwise when made accordingly to procedures for substitutions
68. The general contractor shall notify the COR in writing, or any deficiencies in base building work prior to the commencement of his work. Any unreported deficiencies will become the responsibility of the contractor to correct.
69. Utility outages shall be scheduled outside normal working hours for the affected occupancy unless otherwise indicated.
70. General Contractor shall prearrange with COR, owner and Architect all phasing of the work including demolition, delivery of material, construction, clean up, etc. General Contractor shall coordinate deliveries of material, elevator use, etc. with owner so as not to create conflict with other work or schedules within the building
71. The General Contractors shall verify that all construction documents are the latest issue and that all subcontractors have complete sets of the latest tissue of the construction documents prior to commencing with a portion of the work.
72. All work and material to accomplish designed work shall be stored within the demised space.
73. Just prior to the COR's occupancy of any phase of the work, the general contractor shall clean all surfaces of dust, debris, loose construction materials and equipment and leave all floors vacuum clean.
Remaining construction material and equipment, if any, shall be moved and temporarily secured in an area as directed by the National Park Service.
STRUCTURAL GENERAL NOTES
1. All structure is existing and label as ìEX.î.
2. All work and material to comply with the requirements of the 2015 International Building Code, and
The National Park Service Director's Orders.
3. Other design codes and standards:
a. ACI 318-98 Building Code requirements for reinforced concrete.
b. AISC specification for design, fabrication, and erection of structural steel for building, 9 th edition (1989, Revised 1995).
c. AWS D1.1-98 Structural Welding Code
d. ACI 530-95/ASCE 5-96 Building Code requirements for masonry structures.
4. Live Loads:
a. Typical Roof 30 PSF of drifting snow, whichever is greater
Snow Load Factors Pg = 30 PSF
Pf = 21 PSF
Ce = 0.7
I = 1.0
Ct = 1.0
b. Typical Floor 80 LL + 20 partition
c. Stairs 100 PSF and 300 pound concentrated load
d. Mechanical and Penthouse 100 PSF or machinery weight and 300 pound concentrated load
5. Structural Steel
a. All structural steel wide flange shapes shall conform to ASTM A572 grade 50. All structural steel angles, channel, and plate shall conform to ASTM A36, unless noted otherwise.
b. All structural steel tubing shall conform to ASTM A500, Grade B.
c. All welders, shop and field, shall be certified. Use E70XX electrodes only.
d. All steel exposed to weather in service shall receive an approval exterior paint system or shall be hot dip galvanized, unless otherwise noted.
e. Detailing, fabrication and erection shall be in accordance with AISC. Adequately brace all steel against lateral loads during erection.
f. Connection:
1.) Unless noted or detailed all beam connections shall be simple shear connections.
Where no reaction is provided the beam shall be assumed to carry 120% of allowable uniform load in KIPS for beams laterally supported as give in the AISC steel construction manual. All connections shall be designed for a minimum vertical reaction of 6 KIPS.
2.) Except as noted, all fasteners shall be æî diameter ASTM A325 bolts designed to act in bearing type connections with threads included.
3.) Clip angles and sheer plates used in connections shall have a minimum length and number of bolts as follows:
Beam Depth Min. Length (In.)
W8 5 Ω
W10 - W12 8 Ω
W14 - W16 11 Ω
W18 - W21 14 Ω
g. Web openings cut into any existing or new members shall be approved by structural engineer prior to cutting
6. Steel Stairs:
a. All steel stair stringers shall be continuous MC12 x 10.6 minimum, unless noted otherwise. Stringer shall be mitered and welded with full penetration welds.
b. Platform shall have a minimum 10 gage floor plates with L2 x 2 x ¼ minimum shelf angles on all unsupported sides. Platform plated shall have support spaced at 18 O.C. maximum. Supports shall be L2 ½ x 2 ½ x ¼ or WT3 x 4.25 minimum.
c. Tread and riser plates shall be 10 gage minimum.
d. Stairs shall be designed for a minimum live load of 100 PSF and 300 lb. point load.
7. Light Gauge Metal Framing:
a. Physical and structural properties of cold formed light steel members shall be calculated in accordance with the latest A.I.S.I. specification.
b. Light gage metal framing shall be manufactured by Dale Incor or Marino, equal or better.
c. Steel studs shall be 3 5/8 x 20 gauge (5x = 0.304 in ^3) spaced at 16 O.C., unless noted otherwise.
d. Provide bridging per manufacturer s recommendations.
8. Provided temporary bracing and sharing as required to maintain structural integrity of materials or assemblies. Do not remove temporary bracing or shoring until permanent structure is installed and completer. Contractor to submit for review, temporary shoring and bracing calculations and drawings prepared and signed and sealed by a registered professional engineer, licensed in the state of Maryland
9. All work necessary to support elements of the permanent construction that are not self supporting shall be provided by the contractor. These elements include but are not limited to all finishes, glazing, ceiling, partitions, equipment, piping, ductwork, and conduits. Support will include, but not be limited to framing, hangers, braces, anchors, connections, and the support there of attached to structural elements, unless specifically indicated otherwise.
Design of supports members including all anchors shall be prepared by a professional structural engineer, registered in the District of Columbia and shall by submitted by review by the COR along with elements(s) being supported.
10. Contractor shall field verify all dimensions prior to fabrication of structural components. Do not scale the drawings. These drawings are diagrammatic only, establishing relationship dimensional intent. Any ambiguities, or inconsistencies contained here, shall be reported to the COR at the earliest opportunity.
11. Contractor to coordinate all penetrations, including duct/pipe openings and core drilled holes between trades prior to demolitions and core drilling, submit a fully coordinated, dimensioned plan for approval by structural engineer and architect. Layout and dimensions typically indicated on MEP and Architectural drawings. See structural drawings for typical reinforcing details where required.
12. Reference architectural and MEP drawings for additional general noted, abbreviations, symbols and dimensions.
45. General Contractor and subcontractor shall coordinate the layout and exact location of all joints/connections/anchors, etc. with Architects in the field before proceeding with construction.
46. General Contractor is responsible for and shall provide protection for any and all existing finishes of the
Memorial.
47. Exercise extreme care and precaution during construction of the work to minimize disturbance to the operation of the Memorial and their occupants, property, public thoroughfares, etc. Contractor shall take precautions and be responsible for the safety of all building occupants from construction procedures.
48. Within five (5) days from contract date, prepare and submit and estimated progress schedule for the work with sub-schedules or related activities which may affect the progress.
49. Attachments, connections or fastening of any nature are to be properly secured in conformance with best practice and the contractor is responsible for improving them accordingly and to these conditions.
The drawings show only special conditions to assist contractor they do not illustrate every such detail.
50. The contractor shall continuously check architectural and structural clearances for accessibility of equipment and mechanical and electrical systems. No allowance of any kind will be made for the contractor's negligence to foresee means of installing equipment into position inside structure
OF
AS-101
J e f f e r s o n
M e m o r i a l
P o r t i c o
C e i l i n g
N e t t i n g
S y s t e m
W e s t
P o t o m a c
P a r k
S
W
W a s h i n g t o n
D
C U
CONSULTANT/FIRM:
DESIGNED BY:
DRAWN BY:
CHK'D BY:
DWG NO.:
000000
JJC
JJC
SK
DATE:
03-20-15
0-000
DESCRIPTION
MARK SHEET
03/20/15
DATE
JJC
INITIAL
Division Review
RELEASE DATE / REVISION DATE:
S H
E
T
L E
SEAL:
03/30/15Div. Chief Review JJC
Written dimensions on these drawings shall have precedence over scale dimensions.
Contractor shall verify and be responsible for all dimensions and conditions on the job.
This office must be notified of any variations from the dimensions and conditions.
United States Department of the Interior
National Park Service
M b i l i z a t i o n
P l a n
ENTRANCE STEPS
NORTH TERRACE
TIDAL BASIN
STATUARY
CHAMBER
STYLOBATE MALL
TERRACE MALL
SOUTH PLAZA
WEST
RING
ROAD
EAST
RING
ROAD
PORTICO
Main Construction, storage and delivery entrance
Existing East gate (bars, post and chains to remain).
PVC Coated chain link fence with screening to be maintained at entire time of construction project. Remove at end of contract. Maximum size of staging area shown on plan.
NPS to install minimum area required for proejct staging.
Coordinate w/ Contractor on final size of space.
Exsitng Roadway to remain and be protected from damage during entire project. Contractor to repair any damaged casued during project.
Limits of staging area.
Location of job site trailor if contractor choses to erect on site
Location of Portable toilets
Dumpster location
Construction Entrance
Gates
Construction Entrance
Gates
8'-0"w x 8'-0" h
Construction vehicle parking
Costruction Area for netting project. To be screened from pbulic at all times, See sheet A-
101 for information.
Travel path for contractors and equipment.
Travel path for contractors and equipment.
Designated Access route approved location for vehicle/temporary ramp/material lift access to constrruction site
Security gate entrance for all equipment, vehicles, deliveries, etc.
All items must be screened by Park
Police.
Exsitng Marble steps are off limits to contractor
Exsitng Marble steps are off limits to contractor
Site access Route Site access Route
S i t e a c c e s s
R u t e
S i t e a c c e s s
R o u t e
Existing Planting area to remain. Off- Limits to
Contractor
NORTH PLAZA
N
SCALE: 1" = 30'
Mobilization Plan
AS-101
General Notes
Legend
Limits of Construction
Site Access Route
PVC Coated Chain link fence with screening. 8'-0"
Tall.
PVC Coated Chain link gate with screening. 8'-0" Tall.
Screened Construction
Area. Provide PVC Coated
Chain link fence with screening. 8'-0" Tall.
Designated Access Route -
Approved location for vehicle/temporary ramp/Material equipment lift.
Temporary Job site trailor or dumpster.
Contractor Vehicle Parking
Portable Toilet
Existing Shrubbery to remain
Existing Tree or shrub to remain
Note: All chainlink fencing and screening systems to be supplied by and installed by
National Park Service. Contractor to coordinate size of temporary work site and timing of installation.
1. Contractor shall preserve and protect existing construction and site features at all times and to remain undamaged. Protecting shall be included but not necessarily be limited to location, flagging and protecting utilities, sprinklers, trees, shrubs, walls, sidewalks/curbs and roads from damage by means approved by the contractor’s officer and his representative.
2. Contractor shall verify location of all subsurface tie beams within fenced contraction area on east side of memorial. Construction equipment shall be prohibited from crossing over or being upon any subsurface tie beams.
3. Contractor shall maintain pedestrian access to Jefferson
Memorial from North, West, and South sides at all times.
4. Contractor’s use of cranes, hoists and similar equipment shall be restricted to the portions of the Stylobate mall or terrace mall within the construction zone or by obtaining approval be contracting officer or his representative.
5. Vehicle access to building from existing bituminous roadway over the terrace mall/Stylobate mall shall be restricted to designated access route. At the end of the contract, the area shall be restored to its original condition at the time of notice to proceed.
6. Temporary construction ramps, walks or construction hoist may be installed but shall be permitted only at the designated access route or as approved by contracting officer’s rep.
7. All chain link fencing and screening shall be provide by and installed by National Park Service. Contractor to coordinate with
NPS for exact size of space requirements and timing of installation.
OF
A-101
J e f f e r s o n
M e m o r i a l
P o r t i c o
C e i l i n g
N e t t i n g
S y s t e m
W e s t
P o t o m a c
P a r k
S
W
W a s h i n g t o n
D
C U
CONSULTANT/FIRM:
DESIGNED BY:
DRAWN BY:
CHK'D BY:
DWG NO.:
000000
JJC
JJC
SK
DATE:
03-20-15
0-000
DESCRIPTION
MARK SHEET
03/20/15
DATE
JJC
INITIAL
Division Review
RELEASE DATE / REVISION DATE:
S H
E
T
L E
SEAL:
03/30/15Div. Chief Review JJC
Written dimensions on these drawings shall have precedence over scale dimensions.
Contractor shall verify and be responsible for all dimensions and conditions on the job.
This office must be notified of any variations from the dimensions and conditions.
United States Department of the Interior
National Park Service
M a i n
F l o o r
B a r r i c a d e
P l a n
4'-11"
4'-11"
A-201
A-201
A-201
Location of Debris netting area above. Install above cloumns into architrave.
Construction site barricade: 8'-0"
Tall chain link fence, PVC coated.
Provide Nylon mesh screening around the entire perimeter of columns at work area. Limit to work site on both east and west sides.
This work to be furnished and installed by NPS.
4'-0" x 8'-0" gate w/ screening to match barricade
Construction site barricade: 8'-0"
Tall chain link fence, PVC coated.
Provide Nylon mesh screening around the entire perimeter of columns at work area. Limit to work site on both east and west sides.
This work to be furnished and installed by NPS.
4'-0" x 8'-0" gate w/ screening to match barricade
Contractor must install 3/4" thick T&G plywood over marble floor in work area for the duration of the project.
Contractor must install 3/4" thick T&G plywood over marble floor in work area for the duration of the project.
Location of Debris netting area above. Install above cloumns into architrave.
N
SCALE: 1/16" = 1'-0"
Main Level Plan
A-101
General Notes
Legend
Limits of Construction
Site Access Route
PVC Coated Chain link fence with screening. 8'-0"
Tall.
PVC Coated Chain link gate with screening. 8'-0" Tall.
Screened Construction
Area. Provide PVC Coated
Chain link fence with screening. 8'-0" Tall.
Designated Access Route -
Approved location for vehicle/temporary ramp/Material equipment lift.
Temporary Job site trailor or dumpster.
Contractor Vehicle Parking
Portable Toilet
Existing Shrubbery to remain
Existing Tree or shrub to remain
1. Contractor shall preserve and protect existing construction and site features at all times and to remain undamaged. Protecting shall be included but not necessarily be limited to location, flagging and protecting utilities, sprinklers, trees, shrubs, walls, sidewalks/curbs and roads from damage by means approved by the contractor’s officer and his representative.
2. Contractor shall verify location of all subsurface tie beams within fenced contraction area on east side of memorial. Construction equipment shall be prohibited from crossing over or being upon any subsurface tie beams.
3. Contractor shall maintain pedestrian access to Jefferson
Memorial from North, West, and South sides at all times.
4. Contractor’s use of cranes, hoists and similar equipment shall be restricted to the portions of the Stylobate mall or terrace mall within the construction zone or by obtaining approval be contracting officer or his representative.
5. Vehicle access to building from existing bituminous roadway over the terrace mall/Stylobate mall shall be restricted to designated access route. At the end of the contract, the area shall be restored to its original condition at the time of notice to proceed.
6. Temporary construction ramps, walks or construction hoist may be installed but shall be permitted only at the designated access route or as approved by contracting officer’s rep.
7. All chain link fencing and screening shall be provide by and installed by National Park Service. Contractor to coordinate with
NPS for exact size of space requirements and timing of installation.
OF
A-102
J e f f e r s o n
M e m o r i a l
P o r t i c o
C e i l i n g
N e t t i n g
S y s t e m
W e s t
P o t o m a c
P a r k
S
W
W a s h i n g t o n
D
C U
CONSULTANT/FIRM:
DESIGNED BY:
DRAWN BY:
CHK'D BY:
DWG NO.:
000000
JJC
JJC
SK
DATE:
03-20-15
0-000
DESCRIPTION
MARK SHEET
03/20/15
DATE
JJC
INITIAL
Division Review
RELEASE DATE / REVISION DATE:
S H
E
T
L E
SEAL:
03/30/15Div. Chief Review JJC
Written dimensions on these drawings shall have precedence over scale dimensions.
Contractor shall verify and be responsible for all dimensions and conditions on the job.
This office must be notified of any variations from the dimensions and conditions.
United States Department of the Interior
National Park Service
R e f l e c t e d
C e i l i n g
P l a n
A-102
19'-5" +/-19'-5" +/-
EQ 3'-2
1/2"
3'-2
1/2"
3'-2
1/2"
3'-2
1/2"
EQ
E Q
E Q
E Q
E Q
EQ 3'-2
1/2"
3'-2
1/2"
3'-2
1/2"
3'-2
1/2"
EQ
A-301
A-301
A-301
Exisitng Memorial structure.
11-7/8" Parallam Plus ledger to wrap entire perimeter of ceiling. Provide self-tappping masonry screws into grout joints
ONLY. Provide 3 screws per each joint.
See section for elevation height.
Existing Stone architrave beam
Ex. Stone Column.
11-7/8" Parallam blocking along center line. Between each joist typical. Provide joist hanger at each end.
11-7/8" Parallam joists at 6 equal spaces. Provide joist hangers at each end. NOTE ALL JOIST
LENGTHS ARE TO BE CUT
LONGER THAN SPAN TO
PROVIDE A COMPRESSION FIT
BETWEEN MARBLE BEAMS.
Debris netting to be heavy duty, double stranded, nylon mesh, 2-1/2" square mesh paired with 3/8" knitted polyethylene mesh liner. Mount on top of wood framing with stainless steel snap clips on 3/8" diameter ss perimeter cable through ss eye bolts lagged into top of wood frame.
Existing Stone architrave beam
Ex. Stone Column.
Exisitng Memorial structure.
11-7/8" Parallam Plus ledger to wrap entire perimeter of ceiling. Provide self-tappping masonry screws into grout joints
ONLY. Provide 3 screws per each joint.
See section for elevation height.
Existing Stone architrave beam
Ex. Stone Column.
11-7/8" Parallam blocking along center line. Between each joist typical. Provide joist hanger at each end.
11-7/8" Parallam joists at 6 equal spaces. Provide joist hangers at each end. NOTE ALL JOIST
LENGTHS ARE TO BE CUT
LONGER THAN SPAN TO
PROVIDE A COMPRESSION FIT
BETWEEN MARBLE BEAMS.
Existing Stone architrave beam
Ex. Stone Column.
Debris netting to be heavy duty, double stranded, nylon mesh, 2-1/2" square mesh paired with 3/8" knitted polyethylene mesh liner. Mount on top of wood framing with stainless steel snap clips on 3/8" diameter ss perimeter cable through ss eye bolts lagged into top of wood frame.
VIFVIF
V I F
V I F
NOTE: All framing members, hangers and anchors to be painted with 1 coat of Benjamin
Moor Alkyd Primer 366 and 2 coats of
Benjamin Moore, Aura Waterborne Exterior paint. Semi-gloss Finish. Color to be Silver
Satin OC-26.
A-102
19'-5" +/-19'-5" +/-
A-301
A-301
A-301
Debris netting set in parallam framing system. See enlarged plan for information.
Debris netting set in parallam framing system. See enlarged plan for information.
Existing Stone architrave beam
Ex. Stone Column.
Existing Stone architrave beam
Ex. Stone Column.
NOTE: All framing members, hangers and anchors to be painted with 1 coat of Benjamin
Moor Alkyd Primer 366 and 2 coats of
Benjamin Moore, Aura Waterborne Exterior paint. Semi-gloss Finish. Color to be Silver
Satin OC-26.
A-301
Existing Stone architrave beam
Ex. Stone Column.
11-7/8" Parallam blocking along center line. Between each joist typical. Provide joist hanger at each end.
11-7/8" Parallam joists at 6 equal spaces. Provide joist hangers at each end. NOTE ALL JOIST
LENGTHS ARE TO BE CUT
LONGER THAN SPAN TO
PROVIDE A COMPRESSION FIT
BETWEEN MARBLE BEAMS.
Debris netting to be heavy duty, double stranded, nylon mesh, 2-1/2" square mesh paired with 3/8" knitted polyethylene mesh liner. Mount on top of wood framing with stainless steel snap clips on 3/8" diameter ss perimeter cable through ss eye bolts lagged into top of wood frame.
Ex. Cornice/Gutter above
11-7/8" Parallam Plus Ledger. Install North and
South sides first, then East and West sides. Provide self-tappping masonry screws into grout joints ONLY.
Provide 3 screws per each joint. See section for elevation height.
Install (3) Titen HD self-tapping anchors only in corners and grout joints. 5/8" Diameter x 8" to attain 6" minimum embeddment. Typical of all anchors. Counter sink all anchors into ledger. DO NOT SET
ANCHORS IN FACE OF STONE.
Stainless Steel Joist hangers on all framing members.
Stainless Steel Joist hangers on all framing members.
NOTE: All framing members, hangers and anchors to be painted with 1 coat of Benjamin Moor Alkyd Primer 366 and 2 coats of
Benjamin Moore, Aura Waterborne Exterior paint. Flat Finish.
N
SCALE: 1/4" = 1'-0"
Enlarged Reflecting Ceiling Plan
A-102
SCALE: 1/16" = 1'-0"
Reflected Ceiling Plan
A-102
SCALE: 3/4" = 1'-0"
Corner Plan Detail
A-102
OF
A-201
J e f f e r s o n
M e m o r i a l
P o r t i c o
C e i l i n g
N e t t i n g
S y s t e m
W e s t
P o t o m a c
P a r k
S
W
W a s h i n g t o n
D
C U
CONSULTANT/FIRM:
DESIGNED BY:
DRAWN BY:
CHK'D BY:
DWG NO.:
000000
JJC
JJC
SK
DATE:
03-20-15
0-000
DESCRIPTION
MARK SHEET
03/20/15
DATE
JJC
INITIAL
Division Review
RELEASE DATE / REVISION DATE:
S H
E
T
L E
SEAL:
03/30/15Div. Chief Review JJC
Written dimensions on these drawings shall have precedence over scale dimensions.
Contractor shall verify and be responsible for all dimensions and conditions on the job.
This office must be notified of any variations from the dimensions and conditions.
United States Department of the Interior
National Park Service x t e r i o r
E l e v a t i o n s
A-301
A-301
Location of netting system and structure at interior
Portico Ceiling. See
Section/details for more information.
Location of netting system and structure at interior
Portico Ceiling. See
Section/details for more information.
V
I F
Location of netting system and structure at interior
Portico Ceiling. See
Section/details for more information.
V
I F
A-301
Location of netting system and structure at interior
Portico Ceiling. See
Section/details for more information.
V
I F
A-301
SCALE: 1/16" = 1'-0"
North Elevation
A-201
SCALE: 1/16" = 1'-0"
East Elevation
A-201
SCALE: 1/16" = 1'-0"
West Elevation
A-201
OF
A-301
J e f f e r s o n
M e m o r i a l
P o r t i c o
C e i l i n g
N e t t i n g
S y s t e m
W e s t
P o t o m a c
P a r k
S
W
W a s h i n g t o n
D
C U
CONSULTANT/FIRM:
DESIGNED BY:
DRAWN BY:
CHK'D BY:
DWG NO.:
000000
JJC
JJC
SK
DATE:
03-20-15
0-000
DESCRIPTION
MARK SHEET
03/20/15
DATE
JJC
INITIAL
Division Review
RELEASE DATE / REVISION DATE:
S H
E
T
L E
SEAL:
03/30/15Div. Chief Review JJC
Written dimensions on these drawings shall have precedence over scale dimensions.
Contractor shall verify and be responsible for all dimensions and conditions on the job.
This office must be notified of any variations from the dimensions and conditions.
United States Department of the Interior
National Park Service
P r t i c o N e t t i n g
S e c t i o n s
A-301
A-3013
A-301
A-301
19'-5"
EQ 3'-1
1/2"
3'-2
1/2"
3'-2
1/2"
3'-2
1/2"
EQ
19'-5"
EQ 3'-2
1/2"
3'-2
1/2"
3'-2
1/2"
EQ
11-7/8" Parallam Plus ledger to wrap entire perimeter of ceiling.
Existing Stone architrave beam
Ex. Stone Pilaster
11-7/8" Parallam blocking along center line. Between each joist typical. Provide joist hanger at each end.
11-7/8" Parallam joists at 6 equal spaces. Provide joist hangers at each end. NOTE ALL JOIST
LENGTHS ARE TO BE CUT
LONGER THAN SPAN TO
PROVIDE A COMPRESSION FIT
BETWEEN MARBLE BEAMS.
Debris netting to be heavy duty, double stranded, nylon mesh, 2-1/2" square mesh paired with 3/8" knitted polyethylene mesh liner. Mount on top of wood framing with stainless steel snap clips on 3/8" diameter ss perimeter cable thourhg ss eye bolts lagged into top of wood frame.
Self-tapping masnorny anchors.
Titen HD, by Simpson. Anchor into masnroy joint only. (3) per joint.
Masonry Joint
Ex. Stone Pilaster
Debris netting to be heavy duty, double stranded, nylon mesh, 2-1/2" square mesh paired with 3/8" knitted polyethylene mesh liner. Mount on top of wood framing with stainless steel snap clips on 3/8" diameter ss perimeter cable thourhg ss eye bolts lagged into top of wood frame.
11-7/8" Parallam Plus ledger to wrap entire perimeter of ceiling.
Self-tapping masnorny anchors.
Titen HD, by Simpson. Anchor into masnroy joint only. (3) per joint. Counter sink anchors when behind joists.
11-7/8" Parallam joists at 6 equal spaces. Provide joist hangers at each end. NOTE ALL JOIST
LENGTHS ARE TO BE CUT
LONGER THAN SPAN TO
PROVIDE A COMPRESSION FIT
BETWEEN MARBLE BEAMS.
Ex. Stone Pilaster
Ex. Stone Pilaster
Existing Stone architrave beam
Masonry Joint
11-7/8" Parallam blocking along center line. Between each joist typical. Provide joist hanger at each end.
Top of ColumnTop of Column
V
I F
V
I F
3'-2
1/2"
Joist Hanger anchored to ledger per manufact. req's.
Joist Hanger anchored to ledger per manufact. req's.
A-301
A-301
18'-9
3/4"
EQ EQ
11-7/8" Parallam Plus ledger to wrap entire perimeter of ceiling.
Existing Stone architrave beam
Ex. Stone Column.
11-7/8" Parallam blocking along center line. Between each joist typical. Provide joist hanger at each end.
11-7/8" Parallam joists at 6 equal spaces. Provide joist hangers at each end. NOTE ALL JOIST
LENGTHS ARE TO BE CUT
LONGER THAN SPAN TO
PROVIDE A COMPRESSION FIT
BETWEEN MARBLE BEAMS.
Debris netting to be heavy duty, double stranded, nylon mesh, 2-1/2" square mesh paired with 3/8" knitted polyethylene mesh liner. Mount on top of wood framing with stainless steel snap clips on 3/8" diameter ss perimeter cable thourhg ss eye bolts lagged into top of wood frame.
Self-tapping masnorny anchors.
Titen HD, by Simpson. Anchor into masnroy joint only. (3) per joint.
Masonry Joint
Joist Hanger anchored to ledger per manufact. req's.
Ex. Stone Pilaster beyond
Top of Column
V
I F
Stainless Steel snap clips.
Install per manf.
requriements to achieve loading capacity
Existing Stone architrave beam
Ex. Stone Column.
Debris netting to be heavy duty, double stranded, nylon mesh, 2-1/2" square mesh paired with 3/8" knitted polyethylene mesh liner.
11-7/8" Parallam Plus Ledger. Install
North and South sides first, then East and West sides. Provide self-tappping masonry screws into grout joints
ONLY. Provide 3 screws per each joint. See section for elevation height.
Install (3) Titen HD self-tapping anchors in corners and grout joints.
5/8" Diameter x 8" to attain 6" minimum embeddment. Typical of all anchors. Counter sink all anchors into ledger.
Stainless Steel Joist hangers on all framing members.
Stainless Steel Eye bolts. Min 1/2"x6" embedment into wood framing. Opening to be 3/4" dia. minimum. Run at 12" o.c.
min. Consult with Netting manufacturer for final loading and design requirements.
3/8" Dia. Stainless Steel permieter cable.
Masonry Grout Joint
Wood shims behind ledger board
11-7/8" Parallam joists at 6 equal spaces. Provide joist hangers at each end. NOTE ALL JOIST
LENGTHS ARE TO BE CUT
LONGER THAN SPAN TO
PROVIDE A COMPRESSION FIT
BETWEEN MARBLE BEAMS.
Existing Stone architrave beam
Ex. Stone Column.
11-7/8" Parallam blocking along center line. Between each joist typical. Provide joist hanger at each end.
Debris netting to be heavy duty, double stranded, nylon mesh, 2-1/2" square mesh paired with 3/8" knitted polyethylene mesh liner.
11-7/8" Parallam Plus Ledger. Install
North and South sides first, then East and West sides. Provide self-tappping masonry screws into grout joints
ONLY. Provide 3 screws per each joint. See section for elevation height.
Install (3) Titen HD self-tapping anchors in corners and grout joints.
5/8" Diameter x 8" to attain 6" minimum embeddment. Typical of all anchors. Counter sink all anchors into ledger.
Stainless Steel Joist hangers on all framing members.
Stainless Steel Eye bolts. Min 1/2"x6" embedment into wood framing. Opening to be 3/4" dia. minimum. Run at 12" o.c.
min. Consult with Netting manufacturer for final loading and design requirements.
3/8" Dia. Stainless Steel permieter cable.
Masonry Grout Joint
Wood shims behind ledger board
Stainless Steel snap clips.
Install per manf.
requriements to achieve loading capacity
SCALE: 1/4" = 1'-0"
Netting Longitudinal Section
A-301
SCALE: 1/4" = 1'-0"
Netting Cross Section
A-301
SCALE: 1" = 1'-0"
Ledger Section Detail
A-301
SCALE: 1" = 1'-0"
Joist/Blocking Section Detail
A-301
| A-101 Main Floor Barricade Plan |
| A-101 Main Floor Barricade Plan |
| A-102 Reflected Ceiling Plan |
| A-102 Reflected Ceiling Plan |
| A-201 Exterior Elevations |
| A-201 Exterior Elevations |
| A-301 Portico-Netting Sections |
| A-301 Portico-Netting Sections |
| AS-101 Mobilization Plan |
| AS-101 Mobilization Plan |
| G-001 Cover Sheet |
| G-001 Cover Sheet |
| G-002 Notes, Materials, and Abbrev. |
| G-002 Notes, Materials, and Abbrev. |