P09 13 of 13 Sealed Bid Dwgs 07092020 - 6 pages.pdf

PDF 5 MB Posted

Attached to
Expand and Upgrade Building 42 for Laboratory
Solicitation number
36C25520R0073-0002
Issued by

About this file

This document package includes construction drawings and specifications for the Expand and Upgrade Building 42 for Laboratory project. The scope of work involves upgrading an existing laboratory building and expanding the facility. Key aspects of the project include upgrading mechanical, electrical and fire protection systems; expanding laboratory and support spaces; and installing new data cabling infrastructure to connect the building to the campus network. The construction drawings provide details on proposed renovations and additions to lower, main and interstitial levels. Specifications reference requirements for fire alarm, sprinkler and cabling work. The solicitation is being conducted by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F

F

F

F

F

F

CC

SC

EDC

JBSC

SC

S

EDC

JB

AP

AP

AP

AP

AP

AP

AP

CC

AM

I

AM

I

AM

I

V FS

AM

I

CR

C R

P

ARF

F

S S

F

F

F

S F

F

F

F

C C

F

S

CR

46" MH

EL

CE

CC

EDC

CR

JB

CC

V FS

D

D

D

D

ARF

F

AM

I

D

C

B

A

54321

ESB005A

ECSB002

ET100

Elevator Machine Room

ESB004

Tunnel Access

ECSB002

Stair/Elev Vestibule

ECSB001

M

L

N

P

ESB004

Unfinished Basement

ESB005

NEW TR ABOVE

12"X4" CABLE TRAY

3-4" FIRE RATED SLEEVE ASSEMBLY

UP THROUGH FLOOR ABOVE.

D

N

P

ECSB001

D D

C.2 C.2

2.2

2.2

2.1

2.1

SOUTH

NORTH

MAINnd Floor

LEVEL

100' - 0"

2ND

Floor/InterstiEVEL

117' - 2 1/2"

Existing Lower Level 91' - 9"

Tunnel Level 87' - 9"

Lower Level 85' - 10"

Roof Level 135' - 10"

Stair Roof 150' - 8 1/2"

CC

CC

CC

CC

CC

CC

CC

CC

Drawing Title Project T itle

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

42-AdditionApproved: Associate Director

Approved: Chief of Staff

Approved: Chief Engineer

Approved: Infection Control

Approved: Safety Officer

Approved: Chief, Police & Security o n e e ig h th in c h o n e fo o t 1

BBBB

AAAA

CCCC

DDDD

EEEE

FFFF

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1111 2222 3333 4444 5555 6666 88887777 9999

FFFF

EEEE

DDDD

CCCC

BBBB

AAAA

99997777 8888666655554444333322221111

1 Memorial Dr. STE 1800 Saint Louis, MO 63102

Tel Fax

314.621.4343 314.621.0261

220 N College Ave Indianapolis, IN 46202

Tel Fax

317.464.9090 317.464.9393

Office of Facilities

ManagementMcComas Engineers 1717 E 116th Street Carmel, IN 46032

Tel Fax

317.580.0402 317.582.0766

Structural

Asaturian Eaton & Assoc.

1440 O ld West Main Carbondale, IL 62901

Tel Fax

618.529.3414 618.529.3423

Civil

John A Jurgiel & Assoc.

123 N. Main Street St. Charles, MO 63301

Tel Fax

636.757.3060 636.757.3064

Industrial Hygenist

Holcomb Foundation 393 Wood Road Carbondale, IL 62901

Tel Fax

618.529.5262 618.457.8991

Geotechnical

Heapy Project No.: 2017-05045 Firm License No. 01528

5/28/2020 9:35:42 AM

/2

/2

:3 :4

A

M

LOWER LEVEL FLOOR PLAN -

TECHNOLOGY

Expand & Upgrade Building 42 for Laboratory

ET100

657-502

MARION, ILLINOIS

11/08/2019

BID DOCUMENTS

MSG CLM

N

1/8" = 1'-0"1 LOWER LEVEL PLAN - TECHNOLOGY

GENERAL NOTES

A. REFER TO ARCHITECTURAL DRAW INGS FOR RATED W ALL LOCATIONS.

B. COORDINATE ALL NEW FIRE ALARM/FIRE SUPPRESSION ZONES W ITH COR.

C. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS OF

DEVICES MOUNTED

ABOVE OR BELOW CASEW ORK, FURNITURE, LAVATORIES, ETC.

D. REQUIRED SHUT-DOW NS OF THE SMOKE DETECTION SYSTEM AND FIRE

SUPPRESSION SPRINKLER SYSTEM SHALL NOT OCCUR CONCURRENTLY

AND SHALL COMPLY W ITH THE JOINT COMMISSION ON ACCREDITATION OF

HEALTHCARE ORGANIZATIONS (JCAHO) INTERIM LIFE SAFETY MEASURES

(ILSM). COORDINATION BETW EEN COR AND ALL TRADES SHALL BE

REQUIRED BEFORE SHUT-DOW N OF THE SMOKE DETECTION SYSTEM OR

FIRE SUPPRESSION SPRINKLER SYSTEM.

E. PROVIDE ALL NEW FIRE ALARM BOOSTER PANELS, TRANSPONDER PANELS,

FIBER/COPPER BACKBONE, 120V POW ER CIRCUITS, CONDUIT, ETC. AS

REQUIRED TO SERVE NEW DEVICES. COORDINATE ALL NEW EQUIPMENT

W ITH MANUFACTURER.

F. FIRE ALARM SYSTEM SPEAKERS SHALL USE A CHIME TONE TO MATCH

EXISTING. FUTURE CONVERSION TO VOICE/ALARM IS PLANNED.

1/8" = 1'-0"2 GRADE LEVEL TECHNOLOGY - SOUTH

N

Not to Scale

KEYPLAN - AREA OF WORK

SCALE: 1/4" = 1'-0"

STAIRWELL CAMERA ELEVATIONS

PLAN NOTE

1. PROVIDE FIRE ALARM CONTROL SIGNAL FOR PRIMARY AND ALTERNATE

ELEVATOR RECALL AND FIREMAN'S HAT. PROVIDE FIRE ALARM

MONITORING MODULE FOR LOSS OF VOLTAGE.

2. PROVIDE SYNCHRONIZATION MODULE TO ENSURE NEW STROBES SYNC

TO EXISTING. IF NEW CANNOT BE SYNCHRONIZED, REPLACE EXISTING

CORRIDOR DEVICES W ITH NEW .

3. PROVIDE PHONE LINE W ITH CONNECTION TO ELEVATOR CONTROLLER TO

SERVE CAB MOUNTED TELEPHONE.

4. DISABLE POW ER TO ACCESS CONTROL UPON FIRE ALARM ACTIVATION.

5. FIRE ALARM DEVICE IS TEMPORARY.

1 BULLETIN #1 05/24/2019

F

FF F

F

F

F

F

F

F

F P

D

D

42" MH

42" MH

D

D

D

D D

D

D

D

D

D

D

EDC

CR

JB

CC

CR

EDC

JB

CC

EDC

CR

JB

CC

CC

EDC

JB

K C

EDC

KC

CR

EDC

JB

F

N N N N N

N

ND

W

NM

SC SC SC

SC

SC

SC

SC

V

72" MH

SC SC

SC

SC

SC

SC

SC

SC

CR

EDC

JB

SC

SC

D

D SC

SC

SC

N N

SC

EDC

CR

JB

AP

AP

D

D

D

D

D

SC

SC

CC

D

N

N1 4D

V

72" MH

N N

F

F

F

46" MH

D

D

46" MH

D

46" MH

D

46" MH

D

SC

DB

CC

42" MH

D

SC

46" MH

D

46" MH

D

46" MH

D

46" MH

D

46" MH

D

D

46" MH

46" MH

2D

D

46" MH

2D D

46" MH

2D

D

46" MH

2D D

D

N Z

N Z

N

N

ND

D

N

D

N

D

N

D

N

D D

D

V

72" MH

AP

AP

AP

AP

B

A

654321

E010

E018C

E010A

12'

Conf E026

Waiting E001

Station E003

Station E005

Station E007

Station E009

Station E011

Office E013

Shared Office E015

Office E017

Open Office E010

Phlebotomy E002

Alcove E010A

Office E012

PSA

E014

Pyxis Storage E008

Corridor E018C

P. Toilet E006

Toilet E020

ADA Toilet E022

HAC

E024A

Break Room E024

P. Toilet E004

Shared Office E016

E018B

E008A

12"X4" CABLETRAY

E019

1 1

E002

E025

K

M

L

MATCHLINE

B B

A A

B.2 B.2

2.2

2.2

2.1

2.1

A.6 A.6

A.2 A.2

4.5

4.5

3.5

3.5

2.5

2.5

SOUTH

NORTH

Drawing Title Project T itle

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

42-AdditionApproved: Associate Director

Approved: Chief of Staff

Approved: Chief Engineer

Approved: Infection Control

Approved: Safety Officer

Approved: Chief, Police & Security o n e e ig h o n e fo o t 1

BBBB

AAAA

CCCC

DDDD

EEEE

FFFF

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1111 2222 3333 4444 5555 6666 88887777 9999

FFFF

EEEE

DDDD

CCCC

BBBB

AAAA

99997777 8888666655554444333322221111

1 Memorial Dr. STE 1800 Saint Louis, MO 63102

Tel Fax

314.621.4343 314.621.0261

220 N College Ave Indianapolis, IN 46202

Tel Fax

317.464.9090 317.464.9393

Office of Facilities

ManagementMcComas Engineers 1717 E 116th Street Carmel, IN 46032

Tel Fax

317.580.0402 317.582.0766

Structural

Asaturian Eaton & Assoc.

1440 O ld West Main Carbondale, IL 62901

Tel Fax

618.529.3414 618.529.3423

Civil

John A Jurgiel & Assoc.

123 N. Main Street St. Charles, MO 63301

Tel Fax

636.757.3060 636.757.3064

Industrial Hygenist

Holcomb Foundation 393 Wood Road Carbondale, IL 62901

Tel Fax

618.529.5262 618.457.8991

Geotechnical

Heapy Project No.: 2017-05045 Firm License No. 01528

5/28/2020 9:35:56 AM

/2

/2

:3 :5

A

M

PARTIAL MAIN LEVEL FLOOR

PLAN - TECHNOLOGY

Expand & Upgrade Building 42 for Laboratory

ET101A

657-502

MARION, ILLINOIS

11/08/2019

BID DOCUMENTS

MSG CLM

N

1/4" = 1'-0"1 MAIN LEVEL - NORTH

N

Not to Scale

KEYPLAN - NORTH

GENERAL NOTES

A. REFER TO ARCHITECTURAL DRAW INGS FOR RATED W ALL LOCATIONS.

B. COORDINATE ALL NEW FIRE ALARM/FIRE SUPPRESSION ZONES W ITH COR.

C. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS OF

DEVICES MOUNTED

ABOVE OR BELOW CASEW ORK, FURNITURE, LAVATORIES, ETC.

D. REQUIRED SHUT-DOW NS OF THE SMOKE DETECTION SYSTEM AND FIRE

SUPPRESSION SPRINKLER SYSTEM SHALL NOT OCCUR CONCURRENTLY

AND SHALL COMPLY W ITH THE JOINT COMMISSION ON ACCREDITATION OF

HEALTHCARE ORGANIZATIONS (JCAHO) INTERIM LIFE SAFETY MEASURES

(ILSM). COORDINATION BETW EEN COR AND ALL TRADES SHALL BE

REQUIRED BEFORE SHUT-DOW N OF THE SMOKE DETECTION SYSTEM OR

FIRE SUPPRESSION SPRINKLER SYSTEM.

E. PROVIDE ALL NEW FIRE ALARM BOOSTER PANELS, TRANSPONDER PANELS,

FIBER/COPPER BACKBONE, 120V POW ER CIRCUITS, CONDUIT, ETC. AS

REQUIRED TO SERVE NEW DEVICES. COORDINATE ALL NEW EQUIPMENT

W ITH MANUFACTURER.

F. FIRE ALARM SYSTEM SPEAKERS SHALL USE A CHIME TONE TO MATCH

EXISTING. FUTURE CONVERSION TO VOICE/ALARM IS PLANNED.

PLAN NOTES

1. PROVIDE DATA 72" O.C. IN THREE CHANNEL

ALUMINUM RACEW AY. REFER TO POW ER PLANS.

F

S

F

CC

EDC

KC

JB

SC

SC

SC

SC

SC

SC

SC SC

SC

SC

D

D

SC

SC

SC

SC

CR

46" MH

EL

CE

CC

AP

AP

AP

AP

SC

SC

SC

SC

CC

F

F

F

F

SC

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

46" MH

2D

D

46" MH

2D

D 46" MH

2D

D

46" MH

D

46" MH

D

46" MH

D

46" MH

D

46" MH

D

46" MH

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

D

46" MH

D

46" MH

D

46" MH

D

46" MH

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

46" MH

2D

D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

46" MH

2D

D

46" MH

2D D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

M

H2D

D

M

H2D D

M H

2D

D

M

H 2D

D

M

H2D

D

M

H2D D

M H

2D

D

M

H 2D

D

46" MH

2D

D

46" MH

2D

46" MH

2D

D

46" MH

2D

D

46" MH

2D

D

D

46" MH

2D

D

46" MH

2D

46" MH

2D

D

46" MH

2D D

46" MH

2D

D

46" MH

2D D

AR

46" MH

D

D

46" MH

D

46" MH

DD

D

D

D

D D

D

D

2D D

2D D

D D

D

C

654321

E401

1-2", 2-4" C

E027

Stair/Elev Vestibule

EC027

Microbiology E019A

Blood Bank E021

Bio-Safety Level 3 E019B

Acid/Base E023A

Histology E023

IT

E025

ET100

CLG

CLG

CLG

Cooler E018A

1 1

E025

N

P

4 4

D D

C C

C.2 C.2

2.2

2.2

2.1

2.1

4.5

4.5

3.5

3.5

2.5

2.5

SOUTH

NORTH

Drawing Title Project T itle

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

42-AdditionApproved: Associate Director

Approved: Chief of Staff

Approved: Chief Engineer

Approved: Infection Control

Approved: Safety Officer

Approved: Chief, Police & Security o n e e ig h o n e fo o t 1

BBBB

AAAA

CCCC

DDDD

EEEE

FFFF

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1111 2222 3333 4444 5555 6666 88887777 9999

FFFF

EEEE

DDDD

CCCC

BBBB

AAAA

99997777 8888666655554444333322221111

1 Memorial Dr. STE 1800 Saint Louis, MO 63102

Tel Fax

314.621.4343 314.621.0261

220 N College Ave Indianapolis, IN 46202

Tel Fax

317.464.9090 317.464.9393

Office of Facilities

ManagementMcComas Engineers 1717 E 116th Street Carmel, IN 46032

Tel Fax

317.580.0402 317.582.0766

Structural

Asaturian Eaton & Assoc.

1440 O ld West Main Carbondale, IL 62901

Tel Fax

618.529.3414 618.529.3423

Civil

John A Jurgiel & Assoc.

123 N. Main Street St. Charles, MO 63301

Tel Fax

636.757.3060 636.757.3064

Industrial Hygenist

Holcomb Foundation 393 Wood Road Carbondale, IL 62901

Tel Fax

618.529.5262 618.457.8991

Geotechnical

Heapy Project No.: 2017-05045 Firm License No. 01528

5/28/2020 9:36:12 AM

/2

/2

:3 :1

A

M

PARTIAL MAIN LEVEL FLOOR

PLAN - TECHNOLOGY

Expand & Upgrade Building 42 for Laboratory

ET101B

657-502

MARION, ILLINOIS

11/08/2019

BID DOCUMENTS

MSG CLM

N

1/4" = 1'-0"1 MAIN LEVEL - SOUTH

GENERAL NOTES

A. REFER TO ARCHITECTURAL DRAW INGS FOR RATED W ALL LOCATIONS.

B. COORDINATE ALL NEW FIRE ALARM/FIRE SUPPRESSION ZONES W ITH COR.

C. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS OF

DEVICES MOUNTED

ABOVE OR BELOW CASEW ORK, FURNITURE, LAVATORIES, ETC.

D. REQUIRED SHUT-DOW NS OF THE SMOKE DETECTION SYSTEM AND FIRE

SUPPRESSION SPRINKLER SYSTEM SHALL NOT OCCUR CONCURRENTLY

AND SHALL COMPLY W ITH THE JOINT COMMISSION ON ACCREDITATION OF

HEALTHCARE ORGANIZATIONS (JCAHO) INTERIM LIFE SAFETY MEASURES

(ILSM). COORDINATION BETW EEN COR AND ALL TRADES SHALL BE

REQUIRED BEFORE SHUT-DOW N OF THE SMOKE DETECTION SYSTEM OR

FIRE SUPPRESSION SPRINKLER SYSTEM.

E. PROVIDE ALL NEW FIRE ALARM BOOSTER PANELS, TRANSPONDER PANELS,

FIBER/COPPER BACKBONE, 120V POW ER CIRCUITS, CONDUIT, ETC. AS

REQUIRED TO SERVE NEW DEVICES. COORDINATE ALL NEW EQUIPMENT

W ITH MANUFACTURER.

F. FIRE ALARM SYSTEM SPEAKERS SHALL USE A CHIME TONE TO MATCH

EXISTING. FUTURE CONVERSION TO VOICE/ALARM IS PLANNED.

PLAN NOTES

1. PROVIDE DATA 72" O.C. IN THREE CHANNEL

ALUMINUM RACEW AY. REFER TO POW ER PLANS.

2. PROVIDE CARD READER IN ELEVATOR CAB.

COORDINATE W ITH ELEVATOR CONTRACTOR TO

PROVIDE THE REQUIRED CABLING IN THE

TRAVELING CABLE.

3. PROVIDE ELEVATOR CONTROLLER INTERFACE

PANEL ALONG W ITH REQUIRED W IRING AND

PROGRAMMING FOR CARD READER CONTROL OF

ELEVATOR FLOOR SELECTOR.

4. OUTLET TO BE INSTALLED IN POW ER POLE.

N

Not to Scale

KEYPLAN - SOUTH

EDC

CR

CC

CC

CC

F

F

F

F

S S

S S

S R

S R

R W

R W

R W

R W

S

S

S

S

S

SC

FACP

JB

CC

AP

AP

JB

EDC

CRCR

D

CC

AP

AP

ARAR

S

F

F

H

CR CR

EDC

JB

CC

AR

D

C

B

A

54321

Mechanical Room

E102

Mechanical Room

E102

E102A

E102B

AHU-1

AHU-2

M

L

N

P

Stair/ Elev Vestibule

EC101

D D

C C

B B

A A

C.2 C.2

B.2 B.2

2.2

2.2

2.1

2.1

A.6 A.6

A.2 A.2

4.5

4.5

3.5

3.5

2.5

2.5

SOUTH

NORTH

EC201

Elevator

EL1

D D

C.2 C.2

2.2

2.2

2.1

2.1

Drawing Title Project T itle

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

42-AdditionApproved: Associate Director

Approved: Chief of Staff

Approved: Chief Engineer

Approved: Infection Control

Approved: Safety Officer

Approved: Chief, Police & Security o n e e ig h o n e fo o t 1

BBBB

AAAA

CCCC

DDDD

EEEE

FFFF

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1111 2222 3333 4444 5555 6666 88887777 9999

FFFF

EEEE

DDDD

CCCC

BBBB

AAAA

99997777 8888666655554444333322221111

1 Memorial Dr. STE 1800 Saint Louis, MO 63102

Tel Fax

314.621.4343 314.621.0261

220 N College Ave Indianapolis, IN 46202

Tel Fax

317.464.9090 317.464.9393

Office of Facilities

ManagementMcComas Engineers 1717 E 116th Street Carmel, IN 46032

Tel Fax

317.580.0402 317.582.0766

Structural

Asaturian Eaton & Assoc.

1440 O ld West Main Carbondale, IL 62901

Tel Fax

618.529.3414 618.529.3423

Civil

John A Jurgiel & Assoc.

123 N. Main Street St. Charles, MO 63301

Tel Fax

636.757.3060 636.757.3064

Industrial Hygenist

Holcomb Foundation 393 Wood Road Carbondale, IL 62901

Tel Fax

618.529.5262 618.457.8991

Geotechnical

Heapy Project No.: 2017-05045 Firm License No. 01528

5/28/2020 9:36:23 AM

/2

/2

:3 :2

A

M

INTERSTITIAL LEVEL FLOOR

PLAN - TECHNOLOGY

Expand & Upgrade Building 42 for Laboratory

ET102

657-502

MARION, ILLINOIS

11/08/2019

BID DOCUMENTS

MSG CLM

N

1/8" = 1'-0"1 INTERSTITIAL LEVEL - TECHNOLOGY

GENERAL NOTES

A. REFER TO ARCHITECTURAL DRAW INGS FOR RATED W ALL LOCATIONS.

B. COORDINATE ALL NEW FIRE ALARM/FIRE SUPPRESSION ZONES W ITH COR.

C. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS OF

DEVICES MOUNTED

ABOVE OR BELOW CASEW ORK, FURNITURE, LAVATORIES, ETC.

D. REQUIRED SHUT-DOW NS OF THE SMOKE DETECTION SYSTEM AND FIRE

SUPPRESSION SPRINKLER SYSTEM SHALL NOT OCCUR CONCURRENTLY

AND SHALL COMPLY W ITH THE JOINT COMMISSION ON ACCREDITATION OF

HEALTHCARE ORGANIZATIONS (JCAHO) INTERIM LIFE SAFETY MEASURES

(ILSM). COORDINATION BETW EEN COR AND ALL TRADES SHALL BE

REQUIRED BEFORE SHUT-DOW N OF THE SMOKE DETECTION SYSTEM OR

FIRE SUPPRESSION SPRINKLER SYSTEM.

E. PROVIDE ALL NEW FIRE ALARM BOOSTER PANELS, TRANSPONDER PANELS,

FIBER/COPPER BACKBONE, 120V POW ER CIRCUITS, CONDUIT, ETC. AS

REQUIRED TO SERVE NEW DEVICES. COORDINATE ALL NEW EQUIPMENT

W ITH MANUFACTURER.

F. FIRE ALARM SYSTEM SPEAKERS SHALL USE A CHIME TONE TO MATCH

EXISTING. FUTURE CONVERSION TO VOICE/ALARM IS PLANNED.

PLAN NOTE

1. FIRE ALARM BOOSTER PANEL. RUN BACKBONE CABLING IN 1" C. TO

EXISTING BUILDING 42 HEADEND. PROVIDE FIRE ALARM TRANSPONDER/

BOOSTER PANEL AS REQUIRED BY MANUFACTURER. COORDINATE W ORK

W ITH SIEMENS.

2. AP TO BE STEM MOUNTED AT 12'-0" AFF. COORDINATE W ITH MECHANICAL

INSTALLATION SO THAT DEVICE IS NOT LOCATED DIRECTLY ABOVE

DUCTW ORK.

3. INSTALL AT TOP OF SHAFT.

4. COORDINATE EXACT LOCATION W ITH DIV. 23.

N

Not to Scale

KEYPLAN - AREA OF WORK

SCALE: 1/8" = 1'-0"

PARTIAL ROOF PLAN-TECH

UP

UP

UP

DN

FEC

FFC FEC

FEC

FEC

FEC

UP

UP

FEC

FEC

103104105105A

110109 111

115 116 117

118B

129130

102A

123A

BUILDING 1

BUILDING 2

BUILDING 1

BUILDING 38

BUILDING 2

Drawing Title Project T itle

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

42-AdditionApproved: Associate Director

Approved: Chief of Staff

Approved: Chief Engineer

Approved: Infection Control

Approved: Safety Officer

Approved: Chief, Police & Security o n e e ig h o n e fo o t 1

BBBB

AAAA

CCCC

DDDD

EEEE

FFFF

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1111 2222 3333 4444 5555 6666 88887777 9999

FFFF

EEEE

DDDD

CCCC

BBBB

AAAA

99997777 8888666655554444333322221111

1 Memorial Dr. STE 1800 Saint Louis, MO 63102

Tel Fax

314.621.4343 314.621.0261

220 N College Ave Indianapolis, IN 46202

Tel Fax

317.464.9090 317.464.9393

Office of Facilities

ManagementMcComas Engineers 1717 E 116th Street Carmel, IN 46032

Tel Fax

317.580.0402 317.582.0766

Structural

Asaturian Eaton & Assoc.

1440 O ld West Main Carbondale, IL 62901

Tel Fax

618.529.3414 618.529.3423

Civil

John A Jurgiel & Assoc.

123 N. Main Street St. Charles, MO 63301

Tel Fax

636.757.3060 636.757.3064

Industrial Hygenist

Holcomb Foundation 393 Wood Road Carbondale, IL 62901

Tel Fax

618.529.5262 618.457.8991

Geotechnical

Heapy Project No.: 2017-05045 Firm License No. 01528

5/28/2020 9:36:35 AM

/2

/2

:3 :3

A

M

BUILDING PLANS - BLDG 1,

BLDG 2, BLDG 37, BLDG, 38

Expand & Upgrade Building 42 for Laboratory

ET200

657-502

MARION, ILLINOIS

11/08/2019

BID DOCUMENTS

MSG JC

SCALE: 1/16" = 1'-0"

BUILDINGS 1, 38, AND 2 SUB-BASEMENT

SCALE: 1/16" = 1'-0"

BUILDINGS 1, 38, AND 2 BASEMENT

SCALE: 1" = 20'-0"

BUILDING 37 FIRST FLOOR

PLAN NOTES

1. EXISTING 66 FRAME, PROVIDE NEW 66 BLOCKS FOR NEW VOICE BACKBONE CABLING. COORDINATE W ITH VA.

2. ROUTE NEW VOICE BACKBONE CABLING ABOVE CEILING, PROVIDE NEW ABOVE CEILING CABLE MANAGEMENT J-

HOOKS.

3. PROVIDE NEW FIBER TERMINATION CABINET IN EXISTING RACK AND TERMINATE NEW FIBER BACKBONE.

4. ROUTE NEW FIBER BACKBONE CABLING ABOVE CEILING, PROVIDE NEW ABOVE CEILING CABLE MANAGEMENT J-

HOOKS.

5. CABLE TO TRANSITION TO EXISTING UNDERGROUND CONDUITS IN EXISTING BUILDING MOUNTED PULLBOX.

6. UTILIZE EXISTING UNDERGROUND CONDUITS, PROVIDE NEW INNERDUCT FOR NEW FIBER BACKBONE.

7. CABLE TO BE ROUTED IN EXISTING CABLE TRAY.

8. CABLE TO EXTEND INTO CABLE TRAY IN EXISTING STEAM TUNNEL. NPROVIDE REQUIRED CORE DRILL PENETRATIONS

W ITH CONDUIT SLEEVES AND FIRESTOP.

9. REFER TO SHEET ET300.

AR

D

C

B

A

54321

NEW SIGNALS CLOSET ABOVE

CT CT

1 2 2-2'' C

CT

CT

CT

4 2-4'' C

D D

C C

B B

A A

C.2 C.2

B.2 B.2

2.2

2.2

2.1

2.1

A.6 A.6

A.2 A.2

4.5

4.5

3.5

3.5

2.5

2.5

Drawing Title Project T itle

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

42-AdditionApproved: Associate Director

Approved: Chief of Staff

Approved: Chief Engineer

Approved: Infection Control

Approved: Safety Officer

Approved: Chief, Police & Security o n e e ig h o n e fo o t 1

BBBB

AAAA

CCCC

DDDD

EEEE

FFFF

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

1111 2222 3333 4444 5555 6666 88887777 9999

FFFF

EEEE

DDDD

CCCC

BBBB

AAAA

99997777 8888666655554444333322221111

1 Memorial Dr. STE 1800 Saint Louis, MO 63102

Tel Fax

314.621.4343 314.621.0261

220 N College Ave Indianapolis, IN 46202

Tel Fax

317.464.9090 317.464.9393

Office of Facilities

ManagementMcComas Engineers 1717 E 116th Street Carmel, IN 46032

Tel Fax

317.580.0402 317.582.0766

Structural

Asaturian Eaton & Assoc.

1440 O ld West Main Carbondale, IL 62901

Tel Fax

618.529.3414 618.529.3423

Civil

John A Jurgiel & Assoc.

123 N. Main Street St. Charles, MO 63301

Tel Fax

636.757.3060 636.757.3064

Industrial Hygenist

Holcomb Foundation 393 Wood Road Carbondale, IL 62901

Tel Fax

618.529.5262 618.457.8991

Geotechnical

Heapy Project No.: 2017-05045 Firm License No. 01528

5/28/2020 9:36:44 AM

/2

/2

:3 :4

A

M

TUNNEL LEVEL BUILDING 42 -

TECHNOLOGY

Expand & Upgrade Building 42 for Laboratory

ET300

657-502

MARION, ILLINOIS

11/08/2019

BID DOCUMENTS

MSG JC

SCALE: 3/32" = 1'-0"

PARTIAL PLAN - BUILDING 42 SUB BASEMENT

PLAN NOTES

1. NEW BACKBONE CABLES INSTALLED IN EXISTING CABLE TRAY IN EXISTING TUNNEL.

2. PROVIDE NEW 2-2" CONDUITS FROM TOP OF TUNNEL, UP INTO PIPE-BASEMENT FOR EXTENSION OF NEW

BACKBONE CABLING. PROVIDE CORE DRILL PENETRATIONS AND REQUIRED FIRESTOP.

3. NEW BACKBONE CABLING TO BE ROUTED IN EXISTING CABLE TRAY.

4. PROVIDE NEW CONUITS AND PULLBOX, FOR ROUTING OF NEW BACKBONE CABLING. EXACT ROUTE AND

ELEVATION OF CONDUIT AND PULLBOX TO BE FIELD COORDINATED W ITH EXISTING CONDITIONS.

5. CONDUIT TO RISE UP TO 1ST FLOOR LEVEL. REFER TO SHEET T101B FOR CONTINUATION. PROVIDE REQUIRED

CORE DRILL PENETRATIONS AND FIRESTOP.

Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets
Sheets

File details come from the government source that posted it. Updated .