P09 13 of 13 Sealed Bid Dwgs 07092020 - 6 pages.pdf
PDF 5 MB Posted
- Attached to
- Expand and Upgrade Building 42 for Laboratory
- Solicitation number
- 36C25520R0073-0002
About this file
This document package includes construction drawings and specifications for the Expand and Upgrade Building 42 for Laboratory project. The scope of work involves upgrading an existing laboratory building and expanding the facility. Key aspects of the project include upgrading mechanical, electrical and fire protection systems; expanding laboratory and support spaces; and installing new data cabling infrastructure to connect the building to the campus network. The construction drawings provide details on proposed renovations and additions to lower, main and interstitial levels. Specifications reference requirements for fire alarm, sprinkler and cabling work. The solicitation is being conducted by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F
F
F
F
F
F
CC
SC
EDC
JBSC
SC
S
EDC
JB
AP
AP
AP
AP
AP
AP
AP
CC
AM
I
AM
I
AM
I
V FS
AM
I
CR
C R
P
ARF
F
S S
F
F
F
S F
F
F
F
C C
F
S
CR
46" MH
EL
CE
CC
EDC
CR
JB
CC
V FS
D
D
D
D
ARF
F
AM
I
D
C
B
A
54321
ESB005A
ECSB002
ET100
Elevator Machine Room
ESB004
Tunnel Access
ECSB002
Stair/Elev Vestibule
ECSB001
M
L
N
P
ESB004
Unfinished Basement
ESB005
NEW TR ABOVE
12"X4" CABLE TRAY
3-4" FIRE RATED SLEEVE ASSEMBLY
UP THROUGH FLOOR ABOVE.
D
N
P
ECSB001
D D
C.2 C.2
2.2
2.2
2.1
2.1
SOUTH
NORTH
MAINnd Floor
LEVEL
100' - 0"
2ND
Floor/InterstiEVEL
117' - 2 1/2"
Existing Lower Level 91' - 9"
Tunnel Level 87' - 9"
Lower Level 85' - 10"
Roof Level 135' - 10"
Stair Roof 150' - 8 1/2"
CC
CC
CC
CC
CC
CC
CC
CC
Drawing Title Project T itle
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
42-AdditionApproved: Associate Director
Approved: Chief of Staff
Approved: Chief Engineer
Approved: Infection Control
Approved: Safety Officer
Approved: Chief, Police & Security o n e e ig h th in c h o n e fo o t 1
BBBB
AAAA
CCCC
DDDD
EEEE
FFFF
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1111 2222 3333 4444 5555 6666 88887777 9999
FFFF
EEEE
DDDD
CCCC
BBBB
AAAA
99997777 8888666655554444333322221111
1 Memorial Dr. STE 1800 Saint Louis, MO 63102
Tel Fax
314.621.4343 314.621.0261
220 N College Ave Indianapolis, IN 46202
Tel Fax
317.464.9090 317.464.9393
Office of Facilities
ManagementMcComas Engineers 1717 E 116th Street Carmel, IN 46032
Tel Fax
317.580.0402 317.582.0766
Structural
Asaturian Eaton & Assoc.
1440 O ld West Main Carbondale, IL 62901
Tel Fax
618.529.3414 618.529.3423
Civil
John A Jurgiel & Assoc.
123 N. Main Street St. Charles, MO 63301
Tel Fax
636.757.3060 636.757.3064
Industrial Hygenist
Holcomb Foundation 393 Wood Road Carbondale, IL 62901
Tel Fax
618.529.5262 618.457.8991
Geotechnical
Heapy Project No.: 2017-05045 Firm License No. 01528
5/28/2020 9:35:42 AM
/2
/2
:3 :4
A
M
LOWER LEVEL FLOOR PLAN -
TECHNOLOGY
Expand & Upgrade Building 42 for Laboratory
ET100
657-502
MARION, ILLINOIS
11/08/2019
BID DOCUMENTS
MSG CLM
N
1/8" = 1'-0"1 LOWER LEVEL PLAN - TECHNOLOGY
GENERAL NOTES
A. REFER TO ARCHITECTURAL DRAW INGS FOR RATED W ALL LOCATIONS.
B. COORDINATE ALL NEW FIRE ALARM/FIRE SUPPRESSION ZONES W ITH COR.
C. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS OF
DEVICES MOUNTED
ABOVE OR BELOW CASEW ORK, FURNITURE, LAVATORIES, ETC.
D. REQUIRED SHUT-DOW NS OF THE SMOKE DETECTION SYSTEM AND FIRE
SUPPRESSION SPRINKLER SYSTEM SHALL NOT OCCUR CONCURRENTLY
AND SHALL COMPLY W ITH THE JOINT COMMISSION ON ACCREDITATION OF
HEALTHCARE ORGANIZATIONS (JCAHO) INTERIM LIFE SAFETY MEASURES
(ILSM). COORDINATION BETW EEN COR AND ALL TRADES SHALL BE
REQUIRED BEFORE SHUT-DOW N OF THE SMOKE DETECTION SYSTEM OR
FIRE SUPPRESSION SPRINKLER SYSTEM.
E. PROVIDE ALL NEW FIRE ALARM BOOSTER PANELS, TRANSPONDER PANELS,
FIBER/COPPER BACKBONE, 120V POW ER CIRCUITS, CONDUIT, ETC. AS
REQUIRED TO SERVE NEW DEVICES. COORDINATE ALL NEW EQUIPMENT
W ITH MANUFACTURER.
F. FIRE ALARM SYSTEM SPEAKERS SHALL USE A CHIME TONE TO MATCH
EXISTING. FUTURE CONVERSION TO VOICE/ALARM IS PLANNED.
1/8" = 1'-0"2 GRADE LEVEL TECHNOLOGY - SOUTH
N
Not to Scale
KEYPLAN - AREA OF WORK
SCALE: 1/4" = 1'-0"
STAIRWELL CAMERA ELEVATIONS
PLAN NOTE
1. PROVIDE FIRE ALARM CONTROL SIGNAL FOR PRIMARY AND ALTERNATE
ELEVATOR RECALL AND FIREMAN'S HAT. PROVIDE FIRE ALARM
MONITORING MODULE FOR LOSS OF VOLTAGE.
2. PROVIDE SYNCHRONIZATION MODULE TO ENSURE NEW STROBES SYNC
TO EXISTING. IF NEW CANNOT BE SYNCHRONIZED, REPLACE EXISTING
CORRIDOR DEVICES W ITH NEW .
3. PROVIDE PHONE LINE W ITH CONNECTION TO ELEVATOR CONTROLLER TO
SERVE CAB MOUNTED TELEPHONE.
4. DISABLE POW ER TO ACCESS CONTROL UPON FIRE ALARM ACTIVATION.
5. FIRE ALARM DEVICE IS TEMPORARY.
1 BULLETIN #1 05/24/2019
F
FF F
F
F
F
F
F
F
F P
D
D
42" MH
42" MH
D
D
D
D D
D
D
D
D
D
D
EDC
CR
JB
CC
CR
EDC
JB
CC
EDC
CR
JB
CC
CC
EDC
JB
K C
EDC
KC
CR
EDC
JB
F
N N N N N
N
ND
W
NM
SC SC SC
SC
SC
SC
SC
V
72" MH
SC SC
SC
SC
SC
SC
SC
SC
CR
EDC
JB
SC
SC
D
D SC
SC
SC
N N
SC
EDC
CR
JB
AP
AP
D
D
D
D
D
SC
SC
CC
D
N
N1 4D
V
72" MH
N N
F
F
F
46" MH
D
D
46" MH
D
46" MH
D
46" MH
D
SC
DB
CC
42" MH
D
SC
46" MH
D
46" MH
D
46" MH
D
46" MH
D
46" MH
D
D
46" MH
46" MH
2D
D
46" MH
2D D
46" MH
2D
D
46" MH
2D D
D
N Z
N Z
N
N
ND
D
N
D
N
D
N
D
N
D D
D
V
72" MH
AP
AP
AP
AP
B
A
654321
E010
E018C
E010A
12'
Conf E026
Waiting E001
Station E003
Station E005
Station E007
Station E009
Station E011
Office E013
Shared Office E015
Office E017
Open Office E010
Phlebotomy E002
Alcove E010A
Office E012
PSA
E014
Pyxis Storage E008
Corridor E018C
P. Toilet E006
Toilet E020
ADA Toilet E022
HAC
E024A
Break Room E024
P. Toilet E004
Shared Office E016
E018B
E008A
12"X4" CABLETRAY
E019
1 1
E002
E025
K
M
L
MATCHLINE
B B
A A
B.2 B.2
2.2
2.2
2.1
2.1
A.6 A.6
A.2 A.2
4.5
4.5
3.5
3.5
2.5
2.5
SOUTH
NORTH
Drawing Title Project T itle
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
42-AdditionApproved: Associate Director
Approved: Chief of Staff
Approved: Chief Engineer
Approved: Infection Control
Approved: Safety Officer
Approved: Chief, Police & Security o n e e ig h o n e fo o t 1
BBBB
AAAA
CCCC
DDDD
EEEE
FFFF
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1111 2222 3333 4444 5555 6666 88887777 9999
FFFF
EEEE
DDDD
CCCC
BBBB
AAAA
99997777 8888666655554444333322221111
1 Memorial Dr. STE 1800 Saint Louis, MO 63102
Tel Fax
314.621.4343 314.621.0261
220 N College Ave Indianapolis, IN 46202
Tel Fax
317.464.9090 317.464.9393
Office of Facilities
ManagementMcComas Engineers 1717 E 116th Street Carmel, IN 46032
Tel Fax
317.580.0402 317.582.0766
Structural
Asaturian Eaton & Assoc.
1440 O ld West Main Carbondale, IL 62901
Tel Fax
618.529.3414 618.529.3423
Civil
John A Jurgiel & Assoc.
123 N. Main Street St. Charles, MO 63301
Tel Fax
636.757.3060 636.757.3064
Industrial Hygenist
Holcomb Foundation 393 Wood Road Carbondale, IL 62901
Tel Fax
618.529.5262 618.457.8991
Geotechnical
Heapy Project No.: 2017-05045 Firm License No. 01528
5/28/2020 9:35:56 AM
/2
/2
:3 :5
A
M
PARTIAL MAIN LEVEL FLOOR
PLAN - TECHNOLOGY
Expand & Upgrade Building 42 for Laboratory
ET101A
657-502
MARION, ILLINOIS
11/08/2019
BID DOCUMENTS
MSG CLM
N
1/4" = 1'-0"1 MAIN LEVEL - NORTH
N
Not to Scale
KEYPLAN - NORTH
GENERAL NOTES
A. REFER TO ARCHITECTURAL DRAW INGS FOR RATED W ALL LOCATIONS.
B. COORDINATE ALL NEW FIRE ALARM/FIRE SUPPRESSION ZONES W ITH COR.
C. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS OF
DEVICES MOUNTED
ABOVE OR BELOW CASEW ORK, FURNITURE, LAVATORIES, ETC.
D. REQUIRED SHUT-DOW NS OF THE SMOKE DETECTION SYSTEM AND FIRE
SUPPRESSION SPRINKLER SYSTEM SHALL NOT OCCUR CONCURRENTLY
AND SHALL COMPLY W ITH THE JOINT COMMISSION ON ACCREDITATION OF
HEALTHCARE ORGANIZATIONS (JCAHO) INTERIM LIFE SAFETY MEASURES
(ILSM). COORDINATION BETW EEN COR AND ALL TRADES SHALL BE
REQUIRED BEFORE SHUT-DOW N OF THE SMOKE DETECTION SYSTEM OR
FIRE SUPPRESSION SPRINKLER SYSTEM.
E. PROVIDE ALL NEW FIRE ALARM BOOSTER PANELS, TRANSPONDER PANELS,
FIBER/COPPER BACKBONE, 120V POW ER CIRCUITS, CONDUIT, ETC. AS
REQUIRED TO SERVE NEW DEVICES. COORDINATE ALL NEW EQUIPMENT
W ITH MANUFACTURER.
F. FIRE ALARM SYSTEM SPEAKERS SHALL USE A CHIME TONE TO MATCH
EXISTING. FUTURE CONVERSION TO VOICE/ALARM IS PLANNED.
PLAN NOTES
1. PROVIDE DATA 72" O.C. IN THREE CHANNEL
ALUMINUM RACEW AY. REFER TO POW ER PLANS.
F
S
F
CC
EDC
KC
JB
SC
SC
SC
SC
SC
SC
SC SC
SC
SC
D
D
SC
SC
SC
SC
CR
46" MH
EL
CE
CC
AP
AP
AP
AP
SC
SC
SC
SC
CC
F
F
F
F
SC
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
46" MH
2D
D
46" MH
2D
D 46" MH
2D
D
46" MH
D
46" MH
D
46" MH
D
46" MH
D
46" MH
D
46" MH
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
D
46" MH
D
46" MH
D
46" MH
D
46" MH
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
46" MH
2D
D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
46" MH
2D
D
46" MH
2D D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
M
H2D
D
M
H2D D
M H
2D
D
M
H 2D
D
M
H2D
D
M
H2D D
M H
2D
D
M
H 2D
D
46" MH
2D
D
46" MH
2D
46" MH
2D
D
46" MH
2D
D
46" MH
2D
D
D
46" MH
2D
D
46" MH
2D
46" MH
2D
D
46" MH
2D D
46" MH
2D
D
46" MH
2D D
AR
46" MH
D
D
46" MH
D
46" MH
DD
D
D
D
D D
D
D
2D D
2D D
D D
D
C
654321
E401
1-2", 2-4" C
E027
Stair/Elev Vestibule
EC027
Microbiology E019A
Blood Bank E021
Bio-Safety Level 3 E019B
Acid/Base E023A
Histology E023
IT
E025
ET100
CLG
CLG
CLG
Cooler E018A
1 1
E025
N
P
4 4
D D
C C
C.2 C.2
2.2
2.2
2.1
2.1
4.5
4.5
3.5
3.5
2.5
2.5
SOUTH
NORTH
Drawing Title Project T itle
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
42-AdditionApproved: Associate Director
Approved: Chief of Staff
Approved: Chief Engineer
Approved: Infection Control
Approved: Safety Officer
Approved: Chief, Police & Security o n e e ig h o n e fo o t 1
BBBB
AAAA
CCCC
DDDD
EEEE
FFFF
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1111 2222 3333 4444 5555 6666 88887777 9999
FFFF
EEEE
DDDD
CCCC
BBBB
AAAA
99997777 8888666655554444333322221111
1 Memorial Dr. STE 1800 Saint Louis, MO 63102
Tel Fax
314.621.4343 314.621.0261
220 N College Ave Indianapolis, IN 46202
Tel Fax
317.464.9090 317.464.9393
Office of Facilities
ManagementMcComas Engineers 1717 E 116th Street Carmel, IN 46032
Tel Fax
317.580.0402 317.582.0766
Structural
Asaturian Eaton & Assoc.
1440 O ld West Main Carbondale, IL 62901
Tel Fax
618.529.3414 618.529.3423
Civil
John A Jurgiel & Assoc.
123 N. Main Street St. Charles, MO 63301
Tel Fax
636.757.3060 636.757.3064
Industrial Hygenist
Holcomb Foundation 393 Wood Road Carbondale, IL 62901
Tel Fax
618.529.5262 618.457.8991
Geotechnical
Heapy Project No.: 2017-05045 Firm License No. 01528
5/28/2020 9:36:12 AM
/2
/2
:3 :1
A
M
PARTIAL MAIN LEVEL FLOOR
PLAN - TECHNOLOGY
Expand & Upgrade Building 42 for Laboratory
ET101B
657-502
MARION, ILLINOIS
11/08/2019
BID DOCUMENTS
MSG CLM
N
1/4" = 1'-0"1 MAIN LEVEL - SOUTH
GENERAL NOTES
A. REFER TO ARCHITECTURAL DRAW INGS FOR RATED W ALL LOCATIONS.
B. COORDINATE ALL NEW FIRE ALARM/FIRE SUPPRESSION ZONES W ITH COR.
C. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS OF
DEVICES MOUNTED
ABOVE OR BELOW CASEW ORK, FURNITURE, LAVATORIES, ETC.
D. REQUIRED SHUT-DOW NS OF THE SMOKE DETECTION SYSTEM AND FIRE
SUPPRESSION SPRINKLER SYSTEM SHALL NOT OCCUR CONCURRENTLY
AND SHALL COMPLY W ITH THE JOINT COMMISSION ON ACCREDITATION OF
HEALTHCARE ORGANIZATIONS (JCAHO) INTERIM LIFE SAFETY MEASURES
(ILSM). COORDINATION BETW EEN COR AND ALL TRADES SHALL BE
REQUIRED BEFORE SHUT-DOW N OF THE SMOKE DETECTION SYSTEM OR
FIRE SUPPRESSION SPRINKLER SYSTEM.
E. PROVIDE ALL NEW FIRE ALARM BOOSTER PANELS, TRANSPONDER PANELS,
FIBER/COPPER BACKBONE, 120V POW ER CIRCUITS, CONDUIT, ETC. AS
REQUIRED TO SERVE NEW DEVICES. COORDINATE ALL NEW EQUIPMENT
W ITH MANUFACTURER.
F. FIRE ALARM SYSTEM SPEAKERS SHALL USE A CHIME TONE TO MATCH
EXISTING. FUTURE CONVERSION TO VOICE/ALARM IS PLANNED.
PLAN NOTES
1. PROVIDE DATA 72" O.C. IN THREE CHANNEL
ALUMINUM RACEW AY. REFER TO POW ER PLANS.
2. PROVIDE CARD READER IN ELEVATOR CAB.
COORDINATE W ITH ELEVATOR CONTRACTOR TO
PROVIDE THE REQUIRED CABLING IN THE
TRAVELING CABLE.
3. PROVIDE ELEVATOR CONTROLLER INTERFACE
PANEL ALONG W ITH REQUIRED W IRING AND
PROGRAMMING FOR CARD READER CONTROL OF
ELEVATOR FLOOR SELECTOR.
4. OUTLET TO BE INSTALLED IN POW ER POLE.
N
Not to Scale
KEYPLAN - SOUTH
EDC
CR
CC
CC
CC
F
F
F
F
S S
S S
S R
S R
R W
R W
R W
R W
S
S
S
S
S
SC
FACP
JB
CC
AP
AP
JB
EDC
CRCR
D
CC
AP
AP
ARAR
S
F
F
H
CR CR
EDC
JB
CC
AR
D
C
B
A
54321
Mechanical Room
E102
Mechanical Room
E102
E102A
E102B
AHU-1
AHU-2
M
L
N
P
Stair/ Elev Vestibule
EC101
D D
C C
B B
A A
C.2 C.2
B.2 B.2
2.2
2.2
2.1
2.1
A.6 A.6
A.2 A.2
4.5
4.5
3.5
3.5
2.5
2.5
SOUTH
NORTH
EC201
Elevator
EL1
D D
C.2 C.2
2.2
2.2
2.1
2.1
Drawing Title Project T itle
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
42-AdditionApproved: Associate Director
Approved: Chief of Staff
Approved: Chief Engineer
Approved: Infection Control
Approved: Safety Officer
Approved: Chief, Police & Security o n e e ig h o n e fo o t 1
BBBB
AAAA
CCCC
DDDD
EEEE
FFFF
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1111 2222 3333 4444 5555 6666 88887777 9999
FFFF
EEEE
DDDD
CCCC
BBBB
AAAA
99997777 8888666655554444333322221111
1 Memorial Dr. STE 1800 Saint Louis, MO 63102
Tel Fax
314.621.4343 314.621.0261
220 N College Ave Indianapolis, IN 46202
Tel Fax
317.464.9090 317.464.9393
Office of Facilities
ManagementMcComas Engineers 1717 E 116th Street Carmel, IN 46032
Tel Fax
317.580.0402 317.582.0766
Structural
Asaturian Eaton & Assoc.
1440 O ld West Main Carbondale, IL 62901
Tel Fax
618.529.3414 618.529.3423
Civil
John A Jurgiel & Assoc.
123 N. Main Street St. Charles, MO 63301
Tel Fax
636.757.3060 636.757.3064
Industrial Hygenist
Holcomb Foundation 393 Wood Road Carbondale, IL 62901
Tel Fax
618.529.5262 618.457.8991
Geotechnical
Heapy Project No.: 2017-05045 Firm License No. 01528
5/28/2020 9:36:23 AM
/2
/2
:3 :2
A
M
INTERSTITIAL LEVEL FLOOR
PLAN - TECHNOLOGY
Expand & Upgrade Building 42 for Laboratory
ET102
657-502
MARION, ILLINOIS
11/08/2019
BID DOCUMENTS
MSG CLM
N
1/8" = 1'-0"1 INTERSTITIAL LEVEL - TECHNOLOGY
GENERAL NOTES
A. REFER TO ARCHITECTURAL DRAW INGS FOR RATED W ALL LOCATIONS.
B. COORDINATE ALL NEW FIRE ALARM/FIRE SUPPRESSION ZONES W ITH COR.
C. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS OF
DEVICES MOUNTED
ABOVE OR BELOW CASEW ORK, FURNITURE, LAVATORIES, ETC.
D. REQUIRED SHUT-DOW NS OF THE SMOKE DETECTION SYSTEM AND FIRE
SUPPRESSION SPRINKLER SYSTEM SHALL NOT OCCUR CONCURRENTLY
AND SHALL COMPLY W ITH THE JOINT COMMISSION ON ACCREDITATION OF
HEALTHCARE ORGANIZATIONS (JCAHO) INTERIM LIFE SAFETY MEASURES
(ILSM). COORDINATION BETW EEN COR AND ALL TRADES SHALL BE
REQUIRED BEFORE SHUT-DOW N OF THE SMOKE DETECTION SYSTEM OR
FIRE SUPPRESSION SPRINKLER SYSTEM.
E. PROVIDE ALL NEW FIRE ALARM BOOSTER PANELS, TRANSPONDER PANELS,
FIBER/COPPER BACKBONE, 120V POW ER CIRCUITS, CONDUIT, ETC. AS
REQUIRED TO SERVE NEW DEVICES. COORDINATE ALL NEW EQUIPMENT
W ITH MANUFACTURER.
F. FIRE ALARM SYSTEM SPEAKERS SHALL USE A CHIME TONE TO MATCH
EXISTING. FUTURE CONVERSION TO VOICE/ALARM IS PLANNED.
PLAN NOTE
1. FIRE ALARM BOOSTER PANEL. RUN BACKBONE CABLING IN 1" C. TO
EXISTING BUILDING 42 HEADEND. PROVIDE FIRE ALARM TRANSPONDER/
BOOSTER PANEL AS REQUIRED BY MANUFACTURER. COORDINATE W ORK
W ITH SIEMENS.
2. AP TO BE STEM MOUNTED AT 12'-0" AFF. COORDINATE W ITH MECHANICAL
INSTALLATION SO THAT DEVICE IS NOT LOCATED DIRECTLY ABOVE
DUCTW ORK.
3. INSTALL AT TOP OF SHAFT.
4. COORDINATE EXACT LOCATION W ITH DIV. 23.
N
Not to Scale
KEYPLAN - AREA OF WORK
SCALE: 1/8" = 1'-0"
PARTIAL ROOF PLAN-TECH
UP
UP
UP
DN
FEC
FFC FEC
FEC
FEC
FEC
UP
UP
FEC
FEC
103104105105A
110109 111
115 116 117
118B
129130
102A
123A
BUILDING 1
BUILDING 2
BUILDING 1
BUILDING 38
BUILDING 2
Drawing Title Project T itle
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
42-AdditionApproved: Associate Director
Approved: Chief of Staff
Approved: Chief Engineer
Approved: Infection Control
Approved: Safety Officer
Approved: Chief, Police & Security o n e e ig h o n e fo o t 1
BBBB
AAAA
CCCC
DDDD
EEEE
FFFF
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1111 2222 3333 4444 5555 6666 88887777 9999
FFFF
EEEE
DDDD
CCCC
BBBB
AAAA
99997777 8888666655554444333322221111
1 Memorial Dr. STE 1800 Saint Louis, MO 63102
Tel Fax
314.621.4343 314.621.0261
220 N College Ave Indianapolis, IN 46202
Tel Fax
317.464.9090 317.464.9393
Office of Facilities
ManagementMcComas Engineers 1717 E 116th Street Carmel, IN 46032
Tel Fax
317.580.0402 317.582.0766
Structural
Asaturian Eaton & Assoc.
1440 O ld West Main Carbondale, IL 62901
Tel Fax
618.529.3414 618.529.3423
Civil
John A Jurgiel & Assoc.
123 N. Main Street St. Charles, MO 63301
Tel Fax
636.757.3060 636.757.3064
Industrial Hygenist
Holcomb Foundation 393 Wood Road Carbondale, IL 62901
Tel Fax
618.529.5262 618.457.8991
Geotechnical
Heapy Project No.: 2017-05045 Firm License No. 01528
5/28/2020 9:36:35 AM
/2
/2
:3 :3
A
M
BUILDING PLANS - BLDG 1,
BLDG 2, BLDG 37, BLDG, 38
Expand & Upgrade Building 42 for Laboratory
ET200
657-502
MARION, ILLINOIS
11/08/2019
BID DOCUMENTS
MSG JC
SCALE: 1/16" = 1'-0"
BUILDINGS 1, 38, AND 2 SUB-BASEMENT
SCALE: 1/16" = 1'-0"
BUILDINGS 1, 38, AND 2 BASEMENT
SCALE: 1" = 20'-0"
BUILDING 37 FIRST FLOOR
PLAN NOTES
1. EXISTING 66 FRAME, PROVIDE NEW 66 BLOCKS FOR NEW VOICE BACKBONE CABLING. COORDINATE W ITH VA.
2. ROUTE NEW VOICE BACKBONE CABLING ABOVE CEILING, PROVIDE NEW ABOVE CEILING CABLE MANAGEMENT J-
HOOKS.
3. PROVIDE NEW FIBER TERMINATION CABINET IN EXISTING RACK AND TERMINATE NEW FIBER BACKBONE.
4. ROUTE NEW FIBER BACKBONE CABLING ABOVE CEILING, PROVIDE NEW ABOVE CEILING CABLE MANAGEMENT J-
HOOKS.
5. CABLE TO TRANSITION TO EXISTING UNDERGROUND CONDUITS IN EXISTING BUILDING MOUNTED PULLBOX.
6. UTILIZE EXISTING UNDERGROUND CONDUITS, PROVIDE NEW INNERDUCT FOR NEW FIBER BACKBONE.
7. CABLE TO BE ROUTED IN EXISTING CABLE TRAY.
8. CABLE TO EXTEND INTO CABLE TRAY IN EXISTING STEAM TUNNEL. NPROVIDE REQUIRED CORE DRILL PENETRATIONS
W ITH CONDUIT SLEEVES AND FIRESTOP.
9. REFER TO SHEET ET300.
AR
D
C
B
A
54321
NEW SIGNALS CLOSET ABOVE
CT CT
1 2 2-2'' C
CT
CT
CT
4 2-4'' C
D D
C C
B B
A A
C.2 C.2
B.2 B.2
2.2
2.2
2.1
2.1
A.6 A.6
A.2 A.2
4.5
4.5
3.5
3.5
2.5
2.5
Drawing Title Project T itle
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
42-AdditionApproved: Associate Director
Approved: Chief of Staff
Approved: Chief Engineer
Approved: Infection Control
Approved: Safety Officer
Approved: Chief, Police & Security o n e e ig h o n e fo o t 1
BBBB
AAAA
CCCC
DDDD
EEEE
FFFF
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1111 2222 3333 4444 5555 6666 88887777 9999
FFFF
EEEE
DDDD
CCCC
BBBB
AAAA
99997777 8888666655554444333322221111
1 Memorial Dr. STE 1800 Saint Louis, MO 63102
Tel Fax
314.621.4343 314.621.0261
220 N College Ave Indianapolis, IN 46202
Tel Fax
317.464.9090 317.464.9393
Office of Facilities
ManagementMcComas Engineers 1717 E 116th Street Carmel, IN 46032
Tel Fax
317.580.0402 317.582.0766
Structural
Asaturian Eaton & Assoc.
1440 O ld West Main Carbondale, IL 62901
Tel Fax
618.529.3414 618.529.3423
Civil
John A Jurgiel & Assoc.
123 N. Main Street St. Charles, MO 63301
Tel Fax
636.757.3060 636.757.3064
Industrial Hygenist
Holcomb Foundation 393 Wood Road Carbondale, IL 62901
Tel Fax
618.529.5262 618.457.8991
Geotechnical
Heapy Project No.: 2017-05045 Firm License No. 01528
5/28/2020 9:36:44 AM
/2
/2
:3 :4
A
M
TUNNEL LEVEL BUILDING 42 -
TECHNOLOGY
Expand & Upgrade Building 42 for Laboratory
ET300
657-502
MARION, ILLINOIS
11/08/2019
BID DOCUMENTS
MSG JC
SCALE: 3/32" = 1'-0"
PARTIAL PLAN - BUILDING 42 SUB BASEMENT
PLAN NOTES
1. NEW BACKBONE CABLES INSTALLED IN EXISTING CABLE TRAY IN EXISTING TUNNEL.
2. PROVIDE NEW 2-2" CONDUITS FROM TOP OF TUNNEL, UP INTO PIPE-BASEMENT FOR EXTENSION OF NEW
BACKBONE CABLING. PROVIDE CORE DRILL PENETRATIONS AND REQUIRED FIRESTOP.
3. NEW BACKBONE CABLING TO BE ROUTED IN EXISTING CABLE TRAY.
4. PROVIDE NEW CONUITS AND PULLBOX, FOR ROUTING OF NEW BACKBONE CABLING. EXACT ROUTE AND
ELEVATION OF CONDUIT AND PULLBOX TO BE FIELD COORDINATED W ITH EXISTING CONDITIONS.
5. CONDUIT TO RISE UP TO 1ST FLOOR LEVEL. REFER TO SHEET T101B FOR CONTINUATION. PROVIDE REQUIRED
CORE DRILL PENETRATIONS AND FIRESTOP.
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
| Sheets |
File details come from the government source that posted it. Updated .