Text version

MJR/ELS

Project No. 4021921 Task No: T1700792

This letter may contain unclassified sensitive information relating to critical technology, which must be protected from release to unauthorized non-US entities and parties not having a valid need-to-know. This document is governed by “Distribution Statement D” which states, “Distribution authorized to DoD and DoD contractors only”. Requests shall be referred to NAVSEA 05D.WARNING – This document contains technical data whose export is restricted by the Arms Export Control Act (Title 22, U.S.C. Sec 2751, et seq.) or the Export

Administration Act of 1979, as amended, Title 50, U.S.C. App 2401, et seq. Violations of these export laws are subject to severe criminal or civil penalties. Disseminate per the provisions of OPNAVINST 5510.161.

GOVERNMENT OPERATIONS OFFICE

1525 Wilson Blvd # 625, Arlington, VA 22209 USA TEL: 1 -703-519-9230 Email: ABSWashingtonDC@eagle.org www.eagle.org

12 December 2017

NATIONAL OCEANIC & ATMOSPHERIC ADMINISTRATION (615875)

MARINE OPERATIONS CENTER – PACIFIC

2002 SE MARINE SCIENCE DRIVE

NEWPORT, OR 97365

Attention: Geoff Wilkie, NavArch <geoffrey.wilkie@noaa.gov>

Subject: BELL M. SHIMADA, VT HALTER MARINE, INC. 1957, ABSID 09199791 Ship - Main Switchboard - GENERATOR KW LOAD SHARE MOD

Attachments: (1) Drawing List

(2) Comments List

Gentlemen:

We have your electronic transmission of 11-Dec-2017 submitting plans and documentation for subject vessel as listed in attachment (1). We have reviewed the plans for compliance with the ABS Rules for Building and Classing

Steel Vessels Under 90 meters (295 feet) in Length (2017). We have to advise that the arrangements and details are satisfactory subject to the work being carried out to the satisfaction of the Surveyors and compliance with the rules in all other respects subject to resolution of comments E-001 to E-005 as listed in attachment (2).

We note that your certification that all materials and processes associated with this submittal are asbestos free is on file with our office. An Invoice for our fee for technical services will be forwarded by separate correspondence.

Electronic copies of the drawings appropriately stamped are available through the ABS Eagle Construct Engineering

Manager (O2E), Web Portal, for your information and use.

Should you have any questions, please contact Michael Roa (mroa@eagle.org) at (703) 519-9240 or the undersigned. Please refer to the above reference number when responding to this correspondence.

Very truly yours, Roy H. Bleiberg Vice President of Engineering ABS Americas

By:________________________ Emil L. Shtaygrud Senior Principal Engineer Ship Engineering Department

Electronically published by ABS Houston.

Reference T1700792, dated 12-DEC-2017.

http://www.eagle.org

MJR/ELS

Project No. 4021921 Task No: T1700792

This letter may contain unclassified sensitive information relating to critical technology, which must be protected from release to unauthorized non-US entities and parties not having a valid need-to-know. This document is governed by “Distribution Statement D” which states, “Distribution authorized to DoD and DoD contractors only”. Requests shall be referred to NAVSEA 05D.WARNING – This document contains technical data whose export is restricted by the Arms Export Control Act (Title 22, U.S.C. Sec 2751, et seq.) or the Export

Administration Act of 1979, as amended, Title 50, U.S.C. App 2401, et seq. Violations of these export laws are subject to severe criminal or civil penalties. Disseminate per the provisions of OPNAVINST 5510.161.

GOVERNMENT OPERATIONS OFFICE

1525 Wilson Blvd # 625, Arlington, VA 22209 USA TEL: 1 -703-519-9230 Email: ABSWashingtonDC@eagle.org www.eagle.org

Attachment (1) - Drawing List

Engineering Office: Houston Ship Engineering

Submitter: NATIONAL OCEANIC & ATMOSPHERIC ADMINISTRATION (615875)

Drawing No Rev Drawing Title

SH-324-FE09 03 600 VOLT MAIN SWITCHBOARD GENERATOR #1 METERING

757 285 4596 - FRV SHIMADA PROPOSED GENERATOR KW LOAD SHARE MODIFCATIONS

Attachment (2) - Comments List

Thread No Comment Text Facilities Action

E-001 SH-324-FE09 - 600 VOLT MAIN SWITCHBOARD GENERATOR #1

METERING

1957[Open] Technical

Please submit a finalized formal updated switchboard wiring diagram (all revised sheets included) with a title block, revision block, revision letter, date, and a detailed bill of materials listing all new components as per U90M Rules 4-6-4/1.3.

E-002 SH-324-FE09 - 600 VOLT MAIN SWITCHBOARD GENERATOR #1

METERING

Provide standard of construction for all new wiring. Instrument and control wiring is to be of the stranded type and is to have heat-resisting and flame-retarding insulation as per U90M Rules 4-6-

4/7.11.4.

E-003 SH-324-FE09 - 600 VOLT MAIN SWITCHBOARD GENERATOR #1

METERING

Please submit cut-sheets for all new components so we may verify compliance with U90M Rules U90M

Rules 4-6-1.

E-004 SH-324-FE09 - 600 VOLT MAIN SWITCHBOARD GENERATOR #1

METERING

Provide ambient temperature ratings for new components; note electronic equipment is to be suitable for operations up to 55 degrees C as per U90M Rules 4-1-1/Table 2.

E-005 SH-324-FE09 - 600 VOLT MAIN SWITCHBOARD GENERATOR #1

METERING

1957[Open] Surveyor

Modifications are to be demonstrated to Surveyor satisfaction as per U90M 4-6-1/21.