This document contains a set of Questions and Answers related to a federal contract opportunity. The contract opportunity is for Ethernet services for the Unmanned Patrol Squadron-19 (VUP-19) Guam Detachment. The solicitation number is N6824624Q0091 and it is being issued as a Request for Quote (RFQ). The contract will be a commercial, firm-fixed price contract with a period of performance of one base year and one option period. The requirement is a 100% Small Business Set-Aside under NAICS code 517111, with a small business size standard of 1,500 employees. The Questions and Answers cover topics such as equipment mounting, last mile connectivity, DISA compliance requirements, ethernet circuit configuration, and wireless solutions. The procurement documents include the Quotation Sheet, Statement of Work, Instructions to Offerors, and Evaluation criteria.

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Question: Can we mount our equipment in CAB 1 -RM 208/ CAB 2 - RM 208?

Answer: Be advised that prior authorization and vetting will be required before any equipment can be mounted/removed from RM 208.

Question: Can Basecomm provide last mile from B25008 to Hangar 7 RM 208?

Answer: The hangar is required to remain air-gapped. Defer to Base Communications for further details.

Question: Are there any requirements/limitations for the equipment to be used? E.g. must they follow DISA-compliance?

Answer: Yes, DISA-compliance is required for all equipment installed. Detailed information on requirements/limitations can be provided upon further request if necessary. (ex. equipment cannot be made in China)

Question: Can both 1Gbps ethernet circuits be provided via 1 switch?

Answer: Yes, it can be provided via 1 switch.

Question: Please advise if Air Fiber is an acceptable solution.

Answer: Anything considered to be a wireless connection cannot be placed in RM 208.

Question: Will the Unmanned Patrol Squadron be responsible for securing the local loop via Base Communications?

Answer: The physical equipment will be secured by us, VUP-19 in the hangar.

Question: Please confirm if there is no configuration requirement on Government owned equipment.

Answer: Configuration requirements in accordance to DISA policies and procedures.

Question: Please confirm that the 1GB Ethernet circuit is a handoff only?

Answer: Please provide additional information on this question. Please explain handoff only?

Reply: Please advise if contractor will terminate the ethernet circuit and Unmanned Patrol Squadron will manage and configure.

Answer: Based on the current setup, the DSTB is controlled/managed by NCTAMS Pacific’s Network Operation Center. With assistance from their representatives the Ethernet circuit can be managed and configured by us, VUP19. Defer further details to NCTAMS PAC as it is possible a different process may be required depending on the equipment utilized.