View the file

Other files for this federal contract opportunity

Other files attached to Support services for existing Evaluation efforts of Electromagnetic Environmental Effects (E3) Command, Control, Communications, Computers, Intelligence, Surveillance, and Reconnaissance(C4ISR) systems., newest first.
File Type Posted
Attachment 11 - NDA Form.pdf PDF
Attachment 10 - Calibration List.xlsx XLSX spreadsheet
Attachment 4 - Pricing Model.xlsx XLSX spreadsheet
Attachment 9 - Estimated Travel Requirements.pdf PDF
N65236-16-R-0005-0001.pdf PDF
Attachment 3 - Small Business Particpation Data.docx DOCX document
Attachment 13 - DD 254.pdf PDF
Attachment 1A and 1B - Reference Information Sheet - Summary and Contract Specific Data.docx DOCX document
N65236-16-R-0005 Questions and Answers.pdf PDF
N65236-16-R-0005 E3 Industry Engagement Annoucement.pdf PDF
16-R-0005 Industry Engagement Brief.pdf PDF
N65236-16-R-0005 E3 RFP Final.pdf PDF
Attachment 8 - CAP.pdf PDF
Attachment 6 - QASP.pdf PDF
Attachment 5 -Small Business Subcontracting Plan Matrix - Updated.xlsx XLSX spreadsheet
N65236-16-R-0005 Pre-Solicitation Notice.pdf PDF
Exhibit A - CDRLs DD Form 1423.pdf PDF
Attachment 2 - Past Performance.docx DOCX document
Attachment 5 -Small Business Subcontracting Plan Matrix - Copy.xlsx XLSX spreadsheet
Attachment 5 - Small Business Participation Matrix.pdf PDF
Attachment 12 - SCA WD Charleston SC 2015-4427 Rev. No. 4.pdf PDF
16-R-0005 Industry Engagement Q&A.pdf PDF
N65236-16-R-0005-0001 (Conformed Copy).pdf PDF
Show all 23

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CO-Site 2D

Antenna 3D

Antenna EMC COMMS Daily (D)

Weekly (W)

Monthl y (M)

Quarterly (Q)

Semi Annual (S)

Annua l (A)

X X X X X X X X

CLIN_0031 X X X

CLIN_0032 X X X

CLIN_0033 X X X

CLIN_0034 X X

CLIN_0035 X X

X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

Inspect/Service Material Handling Equip X X X X X X Clean/Inspect Conex Storage Boxes X X X X X X

X X X X X X X X X X X X X X X X X X

X X X X

X X X X X X X X X X X X X X X X X X

Inspect Jumper Cables (12V & 24V) X X X X X X Inspect 12V Fixed Battery Chargers X X X X X X Inspect 12V Portable Battery Chargers X X X X X X Inspect 24V Fixed Battery Chargers X X X X X X Inspect 24V Portable Battery Charger X X X X X X Inspect 48V Fixed Battery Charger X X X X X X Inspect/Test Security Cameras X X X X X X

CLIN

RF TEST FACILITY (POSEIDON PARK) MAINTENANCE SCHEDULE

Clean/Inspect VTT Ground Plane

CLIN_0039

CLIN_0030

CLIN_0036

CLIN_0037

CLIN_0038

Maintenance Item

Test Affected Periodicity

Clean/Inspect Vehicle Turntable(VTT)

Grease Vehicle Turntable & Gantry Cycle 10 Meter Transmit Mast Clean/Inspect VTT Equipment Berm

Inspect/Test Portable Generators

Clean/Inspect ATT Ground Plane Clean/Inspect Co-Site Ground Box Inspect/Service Diesel Utility Vehicle Inspect/Service Electric Utility Vehicle Inspect/Service 6000# Forklift Clean/Inspect/Test 60kw Site Generator

Inspect/Service Portable Power Tools Inspect/Service Portable Power Cables

Clean/Inspect Ground Plane Trailer Inspect/Service Enclosed Test Trailer

Clean/Inspect/Service Sump Pumps (3ea) Inspect/Service Portable Pumps (2ea)

Inspect/Service Small Engine Equipment

Inspect/Service Fixed Power Tools

Clean/Inspect Antenna Turntable(ATT) Clean/Inspect Composite Turntable(CTT) Clean & Inspect Vehicle Gantry

Clean/Inspect ATT Equipment Berm

RF Test Facility (Poseidon Park) Planned Maintenance # Description 1 Building T‐32 Doors / Walls / Roof / Base / Hurricane Brackets / Lighting Fixtures Visually inspect exterior walls & roof for mechanical defects, water / sun damage, and rust deterioration. Inspect door hinges, latches, locks for proper operation. Inspect interior lighting for proper operation. Inspect interior walls for ant infestation.

2 Building T‐33 Doors / Walls / Roof / Base / Hurricane Brackets / Lighting Fixtures 3 Building T‐34 Doors / Walls / Roof / Base / Hurricane Brackets / Lighting Fixtures 4 Building T‐35 Doors / Walls / Roof / Base / Hurricane Brackets / Lighting Fixtures 5 Vehicle Turn Table (VTT) Operation / Exposed Electrical Conduit / Gas Springs / Rollers / Grease / Drains /

Gearbox / Covers / Submersible Pumps Test for proper operation. Inspect for corrosion, loose, protruding or missing deck bolts. Check inspection hatch gas springs. Check drains for debris. Grease rollers and center bearing. Ensure proper Submersible Pump(s) Operation. Inspect center Ethernet/RF access box for mechanical damage.

6 Vehicle Turn Table Ground Plane Inspect for mechanical damage, loose trim bolts, excessive seam gaps, fire ant infestations.

7 VTT Gantry Operation / Covers / Raise‐Lower / Pumps Test for proper operation. Inspect for vermin feces, insect infestation (wasps, spiders).

8 Antenna Turn Table (ATT) Operation / Rollers / Center Bearing / Chain & Sprockets Test for proper operation. Inspect for vermin nesting, insect infestation (wasps, fire ants, spiders).

9 Composite Turn Table (CTT) Operation / Rollers / Couplings / Drive Belt / Nylon Gears / Controller Box Test for proper operation. Inspect for vermin nesting, insect infestation (wasps, fire ants, spiders) .

10 VTT Berm Fire Extinguishers / Cabinets / Transformer / Electrical Panel / PA System /

Gantry Test Equipment Enclosure Inspect for corrosion, mechanical damage, insect infestation (wasps, fire ants spiders), damaged conduit, sunlight deterioration, plugged A/C filter, 11 ATT Berm Fire Extinguishers / Cabinets / Transformer / Electrical Panel / PA System / Gantry Test Equipment Enclosure

Ditto

12 Co‐Site Testing Enclosure Cover / Cabling / Electrical Service / Heater Inspect for insect infestation (fire ants). Inspect RF cables for deterioration. Inspect condensation heater for mechanical damage / deterioration.

13 Sabre 30’ Extension Mast Operation / Cabling / Laser Height Sensor Test for proper operation. Inspect for vermin nesting, insect infestation (wasps, fire ants, spiders), mechanical damage, 14 Powered Site Entry Gate Operation / Drive Chain / Rollers / Clutch Test for proper operation. Inspect for vermin nesting, insect infestation (wasps, fire ants, spiders), 15 60KW Standby Generator Operation / Oil / Antifreeze Test for proper operation. Inspect for vermin nesting, insect infestation (wasps, fire ants, spiders), 16 6000# Diesel Forklift Operation / Oil / Antifreeze Test for proper operation. Inspect for vermin nesting, insect infestation (wasps, fire ants, spiders), 17 Enclosed Equipment Trailer Operation / 12V Tongue Lift / Levelling Jacks / Lighting Test 12V tongue lift, generator start/run, shore power and lighting. Inspect for vermin nesting, insect infestation (wasps, fire ants, spiders), levelling jack corrosion, tire deterioration/inflation, trailer hitch.

18 Open Trailer Operation / Tires / Tongue Hardware / Electrical Inspect for vermin nesting, insect infestation (wasps, fire ants, spiders), tire deterioration / inflation, trailer hitch.

19 Oil/Water Separator Sub Pump Operation / Sand Level / Oil Skim Test for proper operation. Inspect for presence of oil skim, excess sand in sump.

Conex Box 1 Lighting & Electrical / Doors / Leak Inspection / Hurricane brackets Inspect for leaks, door gasket damage, door latching hardware Conex Box 2 Doors / Leak Inspection Conex Box 3 Doors / Leak Inspection Flammable Locker 1 Doors / Contents Inspect for mechanical / weather damage, leaking contents Flammable Locker 2 Doors / Contents Ditto Utility Vehicle (Ranger) Operation / Oil/ Grease / Anti‐Freeze Test for proper operation. Check fluid levels. Grease/Lube.

Utility Cart (Club Car) Operation / Grease / Battery Condition Test for proper operation. Check battery charge and electrolyte levels. Grease/Lube.

Drill Press Operation / Safety Devices Test for proper operation. Check for mechanical/electrical cord damage.

Band Saw Operation / Safety Devices Test for proper operation. Check for mechanical/electrical cord damage.

Air Compressor Operation / Safety Devices Test for proper operation. Check for mechanical/electrical cord damage.

Emergency Pump (gasoline) Operation / Safety Devices Test for proper operation. Check for mechanical damage.

Emergency Pump (electric) Operation / Safety Devices Test for proper operation. Check for mechanical/electrical cord damage.

Leaf Blower (gasoline) Operation / Safety Devices Test for proper operation. Check for mechanical damage.

Pressure Washer (gasoline) Operation / Safety Devices Test for proper operation. Check for mechanical damage.

Portable Power Tools (corded) Operation / Safety Devices Test for proper operation. Inspect cords and plugs/replace as needed. Inspect rotating parts

1. ½” Drill

2. 3/8” Drill

3. Roto‐Zip

4. 10” Chop Saw

5. Bench Grinder

6. 12” Disk Sander

7. 6” Disk Sander/Polisher

8. 4” Disk Grinder

9. Rotary Hammer

10. Hammer Drill

11. Reciprocating Sander

12. Impact Wrench

Power Tools (battery/cordless)

1. Drill

2. Power Driver

3. Reciprocating Saw

4. Circular Saw

Operation / Safety Devices Test for proper operation. Check for mechanical damage.

Portable Fans Test for proper operation. Check for mechanical/electrical cord damage.

Portable Heaters Test for proper operation. Check for mechanical/electrical cord damage.

Extension Cords Inspect plug ends for deterioration. Cable for tears, rips, mechanical damage.

Portable Lights Test for proper operation. Check for mechanical/electrical cord damage.

Portable Generators (gasoline) Test for proper operation. Check for mechanical damage.

Battery Charger (48V) Club Car Check for mechanical damage, inspect cables and connectors for deterioration.

Battery Charger (24V) Generator Check for mechanical damage, inspect cables and connectors for deterioration.

Battery Charger (24V) Portable Check for mechanical damage, inspect cables and connectors for deterioration.

Battery Charger (12V) Portable Check for mechanical damage, inspect cables and connectors for deterioration.

Battery Charger (12V) Maint. Check for mechanical damage, inspect cables and connectors for deterioration.

Security Cameras Check for mechanical damage, inspect cables and connectors for deterioration.

Extension Cords (120V) Check for mechanical damage, inspect cables and connectors for deterioration.

Jumper Cables (12V) Check for mechanical damage, inspect cables and connectors for deterioration.

Jumper Cables (24V) Check for mechanical damage, inspect cables and connectors for deterioration.

Attachment 7A - Maintenance Schedule