View the file

Other files for this federal contract opportunity

Other files attached to Support services for existing Evaluation efforts of Electromagnetic Environmental Effects (E3) Command, Control, Communications, Computers, Intelligence, Surveillance, and Reconnaissance(C4ISR) systems., newest first.
File Type Posted
Attachment 11 - NDA Form.pdf PDF
Attachment 4 - Pricing Model.xlsx XLSX spreadsheet
Attachment 9 - Estimated Travel Requirements.pdf PDF
N65236-16-R-0005-0001.pdf PDF
Attachment 3 - Small Business Particpation Data.docx DOCX document
Attachment 7A and 7B Mainenance Schedule - Planned Maintenance.pdf PDF
Attachment 13 - DD 254.pdf PDF
Attachment 1A and 1B - Reference Information Sheet - Summary and Contract Specific Data.docx DOCX document
N65236-16-R-0005 Questions and Answers.pdf PDF
N65236-16-R-0005 E3 Industry Engagement Annoucement.pdf PDF
16-R-0005 Industry Engagement Brief.pdf PDF
N65236-16-R-0005 E3 RFP Final.pdf PDF
Attachment 8 - CAP.pdf PDF
Attachment 6 - QASP.pdf PDF
Attachment 5 -Small Business Subcontracting Plan Matrix - Updated.xlsx XLSX spreadsheet
N65236-16-R-0005 Pre-Solicitation Notice.pdf PDF
Exhibit A - CDRLs DD Form 1423.pdf PDF
Attachment 2 - Past Performance.docx DOCX document
Attachment 5 -Small Business Subcontracting Plan Matrix - Copy.xlsx XLSX spreadsheet
Attachment 5 - Small Business Participation Matrix.pdf PDF
Attachment 12 - SCA WD Charleston SC 2015-4427 Rev. No. 4.pdf PDF
16-R-0005 Industry Engagement Q&A.pdf PDF
N65236-16-R-0005-0001 (Conformed Copy).pdf PDF
Show all 23

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RF Test Facility PWS 3.3.1

RF Test Facility (Posiden Park) PWS 3.3.1
MANUFACTUREREQUIPMENT NAMEMODEL NUMBERSERIAL NUMBERCALIBRATION DUE DATECALIBRATION CYCLEcalibration completed
KEYSIGHTNetwork AnalyzerE5072AMY511003424/2/172 year
KEYSIGHTSignal GeneratorE8267DMY515001104/12/172 year
KEYSIGHTSpectrum AnalyzerN9030AMY513807704/12/172 year
AgilentSignal GeneratorE4438CMY490709934/18/172 year
A.H. Systems290-7000MHz Log PeriodicSAS-510-71094/29/172 year
A.H. Systems25-7000MHz BilogicalSAS-521-71234/29/172 year
A.H. Systems25-7000MHz BilogicalSAS-521-71264/29/172 year
A.H. Systems20-330MHz BiconicalSAS-5406354/29/172 year
A.H. Systems20-330MHz BiconicalSAS-5426584/29/172 year
AgilentNetwork AnalyzerE5071BSG424001638/6/172 year
A.H. Systems170MHz-3GHz Dble Rdge Gde HornSAS-57023111/25/172 year
A.H. Systems170MHz-3GHz Dble Rdge Gde HornSAS-57023211/25/172 year
Platform ScaleScale 20KRW-10PRW1150939211/26/172 year
Platform ScaleScale 20KRW-10PRW1150939411/26/172 year
Platform ScaleScale 20KRW-10PRW1240753511/26/172 year
Platform ScaleScale 20KRW-10PRW1240753211/26/172 year
Platform ScaleScale 30KRW-15PRW0120035411/26/172 year
Platform ScaleScale 30KRW-15PRW0120035511/26/172 year
Platform ScaleScale 30KRW-15PRW0120035611/26/172 year
Platform ScaleScale 30KRW-15PRW0120035311/26/172 year
FlukeClamp meter3378351066412/14/172 year
FlukeMultimeter73-37889069112/14/172 year
AgilentInfiniium OscilloscopeDSO8104AMY4951013912/15/172 year
FlukeScope Meter199CDM921027812/15/172 year
KEYSIGHTSpectrum AnalyzerN9030AMY4943016712/16/172 year
A.H. Systems10K-60MHz Active monopoleSAS-550-134312/17/172 year
A.H. Systems1KHz-30MHz Loop AntennaSAS-56417312/17/172 year
AgilentSignal GeneratorE4438CUS4146124212/18/172 year
KEYSIGHTNetwork AnalyzerE5071CMY4610930212/21/172 year
HYPER Log380MHz-8GHz LPA30807020812/29/172 year
A.H. Systems25-7000MHz BilogicalSAS-521-71541/4/182 year
A.H. Systems25-7000MHz BilogicalSAS-521F-71271/4/182 year
A.H. Systems20-330MHz BiconicalSAS-5428161/4/182 year
A.H. Systems10K-60MHz Active monopoleSAS-550-17731/4/182 year
A.H. Systems700Mhz-18GHz Dble Rdge Gde HornSAS-57110041/4/182 year
A.H. Systems700Mhz-18GHz Dble Rdge Gde HornSAS-57110051/4/182 year
A.H. Systems290-7000MHz Log PeriodicSAS-510-71071/14/182 year
ThrulineWattmeter4410A40773/1/182 year
ThrulineWattmeter431688683/1/182 year
AgilentSpectrum AnalyzerN9010ASG480300273/4/182 year
FlukeMultimeter73-38336009512/16/182 year
FlukeMultimeter73-37889069012/16/182 year
AgilentNetwork AnalyzerE5072AMY5110034312/20/182 year
Hewlett-PackardSignal GeneratorE8257DSG4432005612/22/182 year
AgilentSignal GeneratorE4438CUS4146124512/23/182 year
AgilentSignal GeneratorE8247CUS4234026012/23/182 year
AgilentSpectrum AnalyzerE4407BUS414441471/3/192 year
AgilentField Fox RF Analyzer

SPAWAR User: SPAWAR User:

Identify each piece in kit separatelyN9912ASG500286461/12/192 year
AgilentField Fox RF AnalyzerN9912ASG500286551/12/192 year
AgilentSpectrum AnalyzerN9340BSG034801081/12/192 year
AgilentSpectrum AnalyzerN9342CCNO52976181/12/192 year
AgilentNetwork AnalyzerN5241ASG491101022/13/192 year

E3 Analysis PWS 3.3.2

E3 Analysis (RADHAZ) PWS 3.3.2
MANUFACTUREREQUIPMENT NAMEMODEL NUMBERSERIAL NUMBERCALIBRATION DUE DATECALIBRATION CYCLEcalibration completed
ETS-LINDGREN /HOLADAYSYSTEM READOUTHI-4416269773/10/0912 MO
ETS-LINDGREN /HOLADAYSYSTEM READOUTHI-4416829072/24/1012 MO
ETS-LINDGREN /HOLADAYSYSTEM READOUTHI-44161094852/24/1012 MO
F. W. BELLGAUSSMETER51808521192/10/1312 MO
L3-COMMUNICATIONS / NARDAEXPOSURE LEVEL TESTER2304/04 (ELT-400)N-00078/31/1324 MO
L3-COMMUNICATIONS / NARDAB-FIELD PROBE2300/90.10 (ELT-400) 100CMM-04439/29/1324 MO
L3-COMMUNICATIONS / NARDAB-FIELD PROBE2300/90.20 (ELT-400) 3CMC-004410/13/1324 MO
ETS-LINDGREN /HOLADAYINDUCED CLAMP-ON METERHI-3702620592/18/1412 MO
ETS-LINDGREN /HOLADAYINDUCED CLAMP-ON METERHI-3702615422/18/1412 MO
ETS-LINDGREN /HOLADAYSYSTEM READOUTHI-4416829032/18/1412 MO
L3-COMMUNICATIONS / NARDAE & M FIELD PROBE ANALYZEREHP-50D000WX109034/16/1412 MO
L3-COMMUNICATIONS / NARDAE-FIELD PROBE2402/02 EF1891A-01854/26/1424 MO
L3-COMMUNICATIONS / NARDAE-FIELD PROBE2402/03 EF509110066/16/1424 MO
L3-COMMUNICATIONS / NARDAE-FIELD PROBE2402/04 EF609111536/16/1424 MO
L3-COMMUNICATIONS / NARDABROADBAND FIELD METER2401/01 NBM-550B-03916/18/1424 MO
L3-COMMUNICATIONS / NARDABROADBAND FIELD METER2403/01 NBM-520A-01126/18/1424 MO
L3-COMMUNICATIONS / NARDAH-FIELD PROBE2402/05 HF3061A-01546/25/1424 MO
L3-COMMUNICATIONS / NARDAE-FIELD PROBE2402/01 EF0391A-05236/26/1424 MO
L3-COMMUNICATIONS / NARDAH-FIELD PROBE2402/06 HF0191A-01896/26/1424 MO
BIRD ELECTRONICSWATTMETER441025862/15/1524MO
A.H. SYSTEMSANTENNA KIT

SPAWAR User: SPAWAR User:

Identify each piece in kit separatelyAK-40GNONE4/12/1524 MO
A.H. SYSTEMSLOG PERIODIC ANTENNASAS-510-211374/12/1524 MO
A.H. SYSTEMSBALUN/BICONCIAL ANTENNASAS-530, 5426314/12/1524 MO
A.H. SYSTEMSACTIVE MONOPOLE ANTENNASAS-550-1B4224/12/1524 MO
A.H. SYSTEMSDOUBLE RIDGE GUIDE HORNSAS-5717144/12/1524 MO
A.H. SYSTEMSDOUBLE RIDGE GUIDE HORNSAS-5741794/12/1524 MO
A.H. SYSTEMSBROADBAND PREAMPLFIERPAM-02021664/12/1524 MO
A.H. SYSTEMSBROADBAND PREAMPLFIERPAM-01181454/12/1524 MO
A.H. SYSTEMSBROADBAND PREAMPLFIERPAM-18401324/12/1524 MO
EMCOANTENNA330325614/25/1524 MO
AGILENTSPECTRUM ANALYZERE7405A OPT 1D5,1D6,AYX,AYZ,UKBSG451031529/26/1624 MO
L3-COMMUNICATIONS / NARDAE & M FIELD PROBE ANALYZEREHP-200010WJ611123/16/1712 MO
HEWETT PACKARDSPECTRUM ANALYZER8565E3724A007156/6/1736 MO
L3-COMMUNICATIONS / NARDABROADBAND FIELD METER2401/01 NBM-550B-06858/11/1824 MO
L3-COMMUNICATIONS / NARDAH-FIELD PROBE2402/05 HF3061A-02258/11/1824 MO
L3-COMMUNICATIONS / NARDAH-FIELD PROBE2402/06 HF0191A-02268/15/1824 MO
L3-COMMUNICATIONS / NARDAE-FIELD PROBE2402/02 EF1891A-02798/24/1824 MO
L3-COMMUNICATIONS / NARDAE-FIELD PROBE2402/03 EF509111948/24/1824 MO
L3-COMMUNICATIONS / NARDAE-FIELD PROBE2402/04 EF609110248/24/1824 MO
L3-COMMUNICATIONS / NARDAE-FIELD PROBE2402/01 EF0391A-06349/19/1824 MO
L3-COMMUNICATIONS / NARDABROADBAND FIELD METER2403/01 NBM-520C-00269/21/1824 MO

EMI Facility PWS 3.3.4

EMI Facility (461 Lab) PWS 3.3.4
MANUFACTUREREQUIPMENT NAMEMODEL NUMBERSERIAL NUMBERCALIBRATION DUE DATECALIBRATION CYCLEcalibration completed
A.H. SYSTEMSANTENNASAS-550-1B4221/1/0524 MO
HEWLETT PACKARDSPECTRUM ANALYZER8566B2017A005466/18/0536 MO
A.H. SYSTEMSANTENNASAS-550-1B3146/9/0724 MO
A.H. SYSTEMSPREAMPLIFIERPAM-01181726/9/0724 MO
SOLARLINE IMPEDANCE STABL9247-50-TS-50-N9265741/16/1024 MO
SOLARLINE IMPEDANCE STABL9247-50-TS-50-N9676181/16/1024 MO
FISCHER CUSTOM COMMUNICATIONSCALIBRATION FIXTUREFCC-BCICF-196374/17/1124 MO
TEKTRONIXOSCILLOSCOPETDS2022C03244012/30/1124 MO
AMPLIFIER RESEARCHPOWER METERPM 2002NONE5/14/1224 MO
A.H. SYSTEMSDOUBLE RIDGE HORN GUIDESAS-57031910/20/1224 MO
A.H. SYSTEMSDOUBLE RIDGE HORN GUIDESAS-571151910/20/1224 MO
A.H. SYSTEMSANTENNASAS-54071310/20/1224 MO
AGILENTSPECTRUM ANALYZERE4403BUS3921016510/28/1236 MO
ROHDE & SCHWARZSPECTRUM ANALYZERFSH61029113/17/1324 MO
HEWLETT PACKARDSIGNAL GENERATOR3326A2519A011505/13/1336 MO
HEWLETT PACKARDSPECTRUM ANALYZER8562A2741A012707/28/1336 MO
A.H. SYSTEMSANTENNASAS-5406728/24/1324 MO
A.H. SYSTEMSPREAMPLIFIERPAM-02022628/24/1324 MO
SOLARLINE IMPEDANCE STABL9247-50-TS-50-N96257510/19/1324 MO
FISCHER CUSTOM COMMUNICATIONSCALIBRATION FIXTUREFCC-BCICF-156910/24/1324 MO
FLUKEPOWER QUALITY ANALYZER434DM900009111/4/1324 MO
FISCHER CUSTOM COMMUNICATIONSRF CURRENT PROBEF-5511209712/12/1324 MO
FISCHER CUSTOM COMMUNICATIONSRF CURRENT PROBEF-5511209812/12/1324 MO
FISCHER CUSTOM COMMUNICATIONSRF CURRENT PROBEF-120-6A11209512/12/1324 MO
FISCHER CUSTOM COMMUNICATIONSRF CURRENT PROBEF-120-6A11209612/12/1324 MO
AMPLIFIER RESEARCHE-FIELD PROBEFL70303322132/7/1424 MO
AMPLIFIER RESEARCHE-FIELD PROBEFL70183316902/7/1424 MO
AGILENTSPECTRUM ANALYZERN9342C PA7, SIM, TG7, GPSCN052976189/7/1424 MO
HEWLETT PACKARDSPECTRUM ANALYZER8563A3604A0391510/19/1436 MO
AGILENTDIGITAL MULTIMETER34401ASG4700074211/15/1424 MO
A.H. SYSTEMSPREAMPLIFIERPAM-011828511/18/1424 MO
A.H. SYSTEMSPREAMPLIFIERPAM-011833711/18/1424 MO
A.H. SYSTEMSANTENNASAS-550-1B7264/10/1524 MO
A.H. SYSTEMSPREAMPLIFIERPAM-01182334/10/1524 MO
A.H. SYSTEMSPREAMPLIFIERPAM-01183384/10/1524 MO
F. W. BELLGAUSSMETER518012110374/23/1524 MO
HEWLETT PACKARDSPECTRUM ANALYZER8565E3724A007156/6/1536 MO
SOLARLINE IMPEDANCE STABL9233-50-TS-50-N1056156/27/1524 MO
SOLARLINE IMPEDANCE STABL9233-50-TS-50-N1056166/27/1524 MO
SOLARLINE IMPEDANCE STABL9247-50-TS-50-N9335116/27/1524 MO
SOLARLINE IMPEDANCE STABL9247-50-TS-50-N9335126/27/1524 MO
A.H. SYSTEMSPREAMPLIFIERPAM-02023018/5/1524 MO
EM TESTCONTINOUS WAVE SIMCWS 500EV07371029148/28/1524 MO
EM TESTCONTINOUS WAVE SIMCWS 500N2V09351050818/28/1524 MO
EM TESTCONTINOUS WAVE SIMCWS 500N3V09351050828/28/1524 MO
KEITHLYMICRO-OHMMETER5801249/25/1524 MO
EMC-PARTNERIMPULSE TEST EQUIPMENTESD300055310/21/1524 MO
HEWLETT PACKARDSIGNAL GENERATOR8648C3623A0352210/31/1536 MO
SOLARLINE IMPEDANCE STABL9233-50-TS-50-N983291/3/1624 MO
SOLARLINE IMPEDANCE STABL9233-50-TS-50-N983301/3/1624 MO
AMPLIFIER RESEARCHE-FIELD PROBEFL70303382871/14/1624 MO
AMPLIFIER RESEARCHE-FIELD PROBEFL70403386171/14/1624 MO
FISCHER CUSTOM COMMUNICATIONSRF CURRENT PROBEF-5582291/14/1624 MO
FISCHER CUSTOM COMMUNICATIONSRF CURRENT PROBEF-551681/14/1624 MO
FISCHER CUSTOM COMMUNICATIONSRF CURRENT PROBEF-35A1441/14/1624 MO
AGILENTSIGNAL GENERATORE4428CSG490700311/17/1624 MO
FISCHER CUSTOM COMMUNICATIONSRF CURRENT PROBEF-35A1120992/5/1624 MO
HEWLETT PACKARDSIGNAL GENERATOR8648C3623A0351910/31/1636 MO
HEWLETT PACKARDSIGNAL GENERATOR8644A2905A001971/17/1736 MO
ROHDE & SCHWARZTEST RECEIVERESPI1013192/23/1724 MO
FLUKEPOWER QUALITY ANALYZER43BDM86709425/7/1724 MO
ROHDE & SCHWARZTEST RECEIVERESPI1013185/17/1724 MO
A.H. SYSTEMSANTENNASAS-5702676/12/1724 MO
A.H. SYSTEMSANTENNASAS-550-1B8626/12/1724 MO
A.H. SYSTEMSPREAMPLIFIERPAM-01181456/12/1724 MO
FLUKERMS CLAMP METER337997009386/15/1724 MO
ROHDE & SCHWARZPREAMPLIFIERTS-PR181000186/15/1724 MO
SONOMA INSTRUMENTAMPLIFIER310N1867866/15/1724 MO
F. W. BELLGAUSSMETER51808521196/17/1724 MO
F. W. BELLGAUSSMETER50802481146/17/1724 MO
AGILENTOSCILLOSCOPEDSO5052ASG503401049/3/1724 MO
FLUKERMS MULTIMETER179213401409/3/1724 MO
AGILENTSPECTRUM ANALYZERE4440ASG482500879/28/1724 MO
AGILENTWAVEFORM GENERATOR33250ASG4000661011/25/1724 MO
SOLARCURRENT PROBE9207-1895921/6/1824 MO
AGILENTWAVEFORM GENERATOR33220ASG440005123/28/1824 MO
AGILENTSIGNAL GENERATORE8257NSG51110723/29/1824 MO
AMPLIFIER RESEARCHSIGNAL GENERATORSG12003222478/3/1824 MO
AGILENTSPECTRUM ANALYZERE7405ASG451031519/19/1824 MO
ROHDE & SCHWARZEMI TEST RECEIVERESIB261002569/20/1824 MO
HEWLETT PACKARDSIGNAL ANALYZER3561A2844A0564110/10/1824 MO
ROHDE & SCHWARZRECEIVERESU26845637/0152/8/1924 MO
HEWLETT PACKARDSWEEP OSSCILLATOR83650B2933A129644/1/1936 MO
AGILENTOSCILLOSCOPEDSO5052ASG473500019/9/201824 MO
EMC-PARTNERTEST SYSTEMMIG2000-6643N/AN/A
EMC-PARTNERTEST SYSTEMMIG2000-6847N/AN/A

TEMPEST PWS 3.3.5

TEMPEST PWS 3.3.5
MANUFACTUREREQUIPMENT NAMEMODEL NUMBERSERIAL NUMBERCALIBRATION DUE DATECALIBRATION CYCLEcalibration completed
Singer / AiltechImpulse Generator533X-110219-08226/1/9336 MO
Hewlett PackardSpectrum Analyzer 9kHz-1.8GHz8591A3034A013894/14/9536 MO
Rohde&SchwarzSignal GeneratorSMG829490/0249/26/9636 MO
TektronicsOscilloscope 500MHz2440B0136484/4/9736 MO
TektronicsOscilloscope 400MHz2467BB0524154/4/9736 MO
TektronicsOscilloscope 400MHz2467BB0519134/5/9736 MO
TektronicsOscilloscope 400MHz2467BB0524264/6/9736 MO
WavetekSignal Generator2410WT10267/14/0036 MO
Antenna Research AssociatesMagnetic Field AntennaBBH-500/B2449/4/0036 MO
Antenna Research AssociatesMagnetic Field AntennaBBH-500/B2459/5/0036 MO
TektronicsOscilloscope 400MHz2467BB0518775/30/0236 MO
TektronicsOscilloscope 400MHz2467BB0519135/31/0236 MO
TektronicsOscilloscope 400MHz2467BB0524296/1/0236 MO
Antenna Research AssociatesMagnetic Field AntennaBBH-500/A14610/25/0236 MO
Antenna Research AssociatesMagnetic Field AntennaBBH-500/B24110/26/0236 MO
Electro-MetricsDiscone AntennaEM-61151274/22/1036 MO
Hewlett PackardSpectrum Analyzer8560A3128A016027/3/1036 MO
Hewlett PackardSpectrum Analyzer 10kHz-1.5GHz8590A2917U022767/4/1036 MO
Hewlett-PackardTrue RMS Voltmeter3403C1452A0022646/13/1236 MO
Rohde&SchwarzSignal GeneratorSMG829490/0256/15/1236 MO
TIE PIE EngineeringHandyscopeHS-3279341/1/1436 MO
TIE PIE EngineeringHandyscopeHS-3279331/1/1436 MO
AgilentSignal GeneratorMXG N5183AMY474203691/28/1436 MO
Singer / AiltechImpulse Generator533X-110222-08222/1/1436 MO
Singer / AiltechImpulse Generator533X-110343-02232/2/1436 MO
AiltechCurrent Probe94111-162310/1/1536 MO
Electro-MetricsDiscone AntennaEM-611513310/1/1536 MO
Electro-MetricsDiscone AntennaEM-611513410/1/1536 MO
EMCODouble Ridge Waveguide HornEM-3115227910/1/1536 MO
EMCOLog PeriodicEM-3146A9008-114610/1/1536 MO
EMCOLog PeriodicEM-3146A9008-114710/1/1536 MO
ETS-LindgrenDouble Ridge Waveguide Horn31150014641910/1/1536 MO
Carnel LabsImpulse Generator533X-11M91-0110R10/1/1536 MO
StoddardCurrent Probe94550-1BF-36310/1/1536 MO
StoddardCurrent Probe94550-1BF-16110/1/1536 MO
StoddardCurrent Probe90550-1BF-16110/1/1536 MO
FlukeDigital/analog Oscilloscope3394BDM79600310/2/1536 MO
TektronicsDigital OscilloscopeTDS2002BC05106510/10/1636 MO
TektronicsDigital OscilloscopeTDS2002BC01016410/11/1636 MO
Hewlett PackardSpectrum Analyzer 9kHz-22GHz8562A3121A0623110/21/1636 MO
AH SystemsActive Monopole AntennaSAS-550-1B4662/15/1736 MO
AH SystemsDRG Horn AntennaSAS-5718282/16/1736 MO
AH SystemsLog Periodic AntennaSAS-510-213242/17/1736 MO
AH SystemsBiconical/Dipole AntennaSAS-530,5426672/18/1736 MO
AH SystemsLoop AntennaSAS-5608432/19/1736 MO
AH SystemsBroadband Current ProbeBCP-5118742/20/1736 MO
AH SystemsBroadband Current ProbeBCP-5108432/21/1736 MO
AH SystemsLog Periodic AntennaSAS-510-218302/22/1736 MO
AH SystemsBiconical AntennaSAS-544F3672/23/1736 MO
AH SystemsActive Loop/RodEHA-51B2252/24/1736 MO
AH SystemsDouble Ridge Guide Horn AntennaSAS-57122692/25/1736 MO
AgilentOscilloscopeMSOX6004AMY543903693/1/1736 MO
Hewlett-PackardTrue RMS Voltmeter3403C1452A0046233/1/1736 MO
AgilentDifferential ProbeN2793APH532102483/2/1736 MO
HoneywellPLISM3872233/2/1736 MO
AgilentDifferential ProbeN2772AJP420014693/3/1736 MO
HoneywellPLISM3873203/3/1736 MO
AiltechImpulse Generator533X-110336-021743/4/1736 MO
HoneywellPLISM3874223/4/1736 MO
AgilentField Fox Spectrum AnalyzerN9938AMY531038821/30/1936 MO
AgilentEXG Signal Generator

SPAWAR User: SPAWAR User:

Identify each piece in kit separately N5173B MY53270198 1/30/19 36 MO

File details come from the government source that posted it.