AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83)
Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of Amendment #05 is as follow s:
1. To incorporate FINAL Government response to clarif ications received from the industry.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 12
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 15-Mar-2018
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N4033918RF010
X 9B. DATED (SEE ITEM 11)
15-Feb-2018
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
15-Mar-2018
CODE
NAVSUP FLC BAHRAIN CODE 200
FLEET SUPPORT DIVISION PSC 851 BOX 430
FPO AE 09834-0005
N40339 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N4033918RF010
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been added by full text:
AMENDMENT 0005
USNS Kanawha, Clarification Questions
No. WI Question Date Issued
Customer Response
1 Solicitation Please confirm Tender Response Date.
Page 1 Solicitation details 1200 on 08 March Page 8 states 03:00 PM (local Bahrain time) on 06 March 2018 Page 60 states 02:00 PM (local Bahrain time) on 06 March 2018.
28Feb18 Change completed in Amendment #1
2 0040 Solicitation document page 10 of 66, section C-3 Force Protection discusses a requirement for barges. However, the requirement for barges is not specified in Work item 040 Force Protection.
The ships of same class have berthed at the facility previously and there was no requirement for barges. Can you please confirm requirement.
28Feb18 The use of barges is not an MSC requirement.
3 0012 Work item 0021, enclosure reference 2.2.1 refers to USNS Pecos. Can you please confirm that the figures quoted in 2.2.1 pages 7 - 10 are correct for USNS Kanawha?
28Feb18 These figures are accurate for Kanawha
4 0402 Work item 0402 - Can you please clarify a response in which we have received from subcontractor "It is mandatory for us to know if whether there is any alarm in ECDIS in order to quote you accordingly" - Please confirm if there is an alarm present on the ECDIS.
28Feb18 The ECDIS currently has the following, normal in port, alarm displayed: Safety Contour. This comes on when the vessel is in water less than 20 meter deep.
5 0112 Work item 0112 - In order to determine the spare parts required can you please provide the drawings of all of the valves within the work spec.
28Feb18 See Vents, Sounding Tubes and Overflow Drawing
6 Solicitation Solicitation document page 8 of 66 states there are a total of 117 work items, however, we have only have 116? Can you please either provide WI0107 or confirm that this is not required for pricing purposes.
28Feb18 Please see Amendment #1 - There are a total of 117 Work Items; all are provided including WI 0107; WI 0107 is required for pricing purposes.
7 0509 Document 0522_B_Miscellanious Piping Replace.doc is titled Work Item 0509. Can you confirm the correct WI number?
28Feb18 Typo, WI Number is 522
8 0403 Work item 0403 - Section 4.2 states that the is 'none' GFM listed . However, paragraph 7.5.5 lists GFM. Can you please confirm.
28Feb18 Gyrosphere will not be replaced.
Disregard 7.5.5.
9 0519 Work item 0519 - CFM material stated as enclosure 2 on page 1, however, on page 8 it is titled enclosure 1 - can we confirm this is a typo?
28Feb18 From page 8 onward is a typo. It should read Enclosure 2
10 0523 Work item 0523 - 3.2.1 states "See gage list" -there is no enclosure to the document. Can you please confirm the filename of the gage list?
28Feb18 See Kanawha Mastercal
11 0615 Work item 0615 - Can you please confirm the Deck covering surface area.
Can you also provide the missing reference documents "NAVSEA Dwg. No. 634-6240501, Deck Covering Schedule & NSTM Chapter 634, Deck Coverings."
28Feb18 The surface area is twenty five
(25) units at sixty (60) square feet each
12 0915 Work item 0915 -can you please provide the missing ref doc 'Repairing Miscellaneous Valves'
28Feb18 See SWIRRR 22
13 0401 Work item 0401 - Can you please provide the following information which we have received from subcontractor.
"Please provide the expiry dates of the following.
1. EPIRB battery & HRU
2. SART
3. GMDSS Walkie Talkie
4. VDR battery
5. VDR pinger"
28Feb18 1. 6/2019 & 10/2019
2. 11/2022
3. 6/2020
4. 5/2019
5. 5/2019
14 General Please confirm the minimum time between contract award and contract start date.
28Feb18 PoP begin date is 14 May 2018;
Contract award will be issued as soon as it is possible in order to provide as much lead time as possible between contract award date and contract start of PoP date.
15 0001 Work Item 001 para 7.3.1.31 refers to US Coastguard welder qualification. Can you confirm that this is ABS
28Feb18 ABS qualification meets the requirement
16 0106 Work Item 0106 Spot Repairs, tank deck. Square footage is approximate. Please advise maximum deviation % from quantities quoted in the Work Instruction.
This also applies to Work Item 0108.
28Feb18 None. Any additional will be addressed using a change order.
17 0111 Work Item 0111 - Paint Scheme quoted in WI, paragraph 4 does not align to the paint scheme quoted in reference 2.1.1, can you please clarify
28Feb18 Paragraph 4 of the specification applies
18 0113 Work Item 0113 - Para 5.4, states that MSC pay for review and approval. However, para 5.2 puts onus on contractor to arrange ABS to observe, Can you please confirm who would pay for this.
28Feb18 MSC pays the Regulatory Body (ABS)
19 0205 WI0205 has equipment from different manufacturers, and requests a Tech Rep. Can you please identify the Tech Rep in which we should engage.
28Feb18 Gieslinger and Eaton. The following are known to have both qualifications; steve.ho@gcd.com.sg & John Scanlon <john@nolnacsmarine.com>
20 0406 Work item 0406 para 5.1 states that the company shall submit EPIC security clearances.
Can you please provide list of known suppliers.
28Feb18 See COMSCINST 5521.1 for clearance procedure. See E-mail "RE WI 406 C010315U Remote Switching Control Unit Repairs" for sources known to currently have the required certifications and clearance.
21 0907 Work item 0907 - Can you please confirm the requirement for 10,000 sq ft of undercoat repair as this does not align to the % quoted in the Work instruction.
28Feb18 The square footage in 3.1.2 is incorrect. 3.1.2 should read 18000 square feet
22 W1003 Can you please supply the Specification for T Type Hangers.
28Feb18 Production Fastening System. Two slot ESL or equivalent
23 General Can you please advise if there is any asbestos on the Ship. Ship structure will be disturbed/machinery for example band brakes.
28Feb18 The ship is asbestos free
24 0911 Can you please provide the Manual within reference 2.1.1.
28Feb18 See S9303-AA-MMO-010
25 1405 Can you please provide the following reference materials:
1.1 VDR-100G2/G2S Operation and User Manual
(available on-board)
1.2 VDR-100G2/G2S Installation Manual
(available on-board)
1.3 MSC Drawing No.432-8194378 Simplified
Voyage Data Recorder
1.4 MSC Drawing No.436-8194379 Simplified
Voyage Data Recorder
1.5 MSC Drawing No.436-8194380 Simplified
Voyage Data Recorder
28Feb18 Item 1.1 and 1.2 are copy write protected and should be in the possession of the OEM Tech Rep.
Items 1.3, 1.4 and 1.5 do not contain any information required to accurately bid the work item.
26 Various WI’s 0401, 0402, 0404 and 0405 (Tech Rep section) states that the Tech Rep should attend Dock and Sea Trials if required.
Should we cost for attendance?
1Mar18 Yes
27 0613 WI 0613 ERC Change Room Deck Coverings – please confirm if the toilet within the ERC Change Room deck is included within the current scope?
1Mar18 Toilet is not included
28 General Can you please confirm the approximate expected draft of USNS Kanawha on arrival.
1Mar18 See Work Item 0003 Enclosure 2.2.2
29 Solicitation Page 65 and 66. Dock Certification.
Can you please confirm the requirement for a Classification Society to undertake the dry dock survey and subsequently issue a certificate.
Our understanding from the standards is that Graving docks can be surveyed by Professional Engineers, Classification Societies are engaged
1Mar18 Please see COMSC INST 9997.1A Provided when the requirement is to certify a floating dock.
30 0406 We have tried, without success, to source a Manufacturer’s representative as stipulated in WI 0406. Can you please provide a point of contact.
1Mar18 Mid-Atlantic Engineering Technical Services Inc. (MAETS) 1501 Crossways Blvd Suite E Chesapeake, VA 23320-8915 USA POC: Bernie Smith Office: 757-512-5213 Fax: 757-410-0100
INTECH Marine Services 1226 Executive Blvd. Suite 110 Chesapeake, VA. 23320 POC Doug Smith / George Oakley Ph. (757) 549-1143 Fax (757) 549-1174
31 0302 Work Item 0302, Group Controllers are specified as Westinghouse Series 2100, can you please confirm the make, mode and type of the remaining breakers listed in Enclosure 2.2.1.
1Mar18 Westinghouse Power-R Manual provided
32 0206 Paragraph 5.6, Can you please confirm that the exhaust pipe will maintain the correct alignment when all 68 mounts are loosend.
1Mar18 That evaluation will have to be made before the work starts. However, the majority of the exhaust stack is vertical and should remain in place.
33 0521 Paragraph 7.11, Can you please confirm that the contractor is responsible for ABS
1Mar18 The Contractor is responsibile to schedule and facilitate the required ABS and USCG inspections. MSC will provide these inspectors via a service order
34 General please confirm that Amendment No.1 only effects the proposal due date, ship check date and new question deadline. And confirm that the Scope of Work has not changed.
1Mar18
35 Technical
Our baseline proposal assumes the ship will have sole occupancy of a dock. In the event it was a possibility that a second ship was docked alongside, if a suitable physical barrier was put in place between them would this be considered by USMSC? This would only be proposed with the assumption that the operations on the USMSC ship would not be compromised.
8Mar18 Force Protection requirements will not allow docking another ship within 100 yards.
36 Supply Chain 1004
Material supplier declined to Quote due to US export restrictions. Can you please either agree a way forward for the supplier to nominate an agent or send CQ to customer.
8Mar18 The requirement is that the material meets the rerquirement of ASTMD4020. Locally procured material meeting this requirement is acceptable
37 Schedule
Can you please confirm when a decision on WI 914 will be taken and that a schedule extension will be granted to accommodate the associated work.
8Mar18 This decision is based on the outcome of 0913 and 0917. The completion of these work items is based on the scheduling and productivity of the contractor. If the productivity of the contractor is timely and efficient an extension should not be required.
Extensions will be addressed on a case by case basis.
38 Technical
Can you please provide the drawing for the Bilge Keel
8Mar18 Provided
39 Technical
SWIRRR 16 (2.1 Reference Document) Part C Hydrostatic Test states test pressure shall be
1.25 x WP. Pressures quoted for hydrostatic testing in WI502 para 3 are 1.5xWP. Please confirm correct test pressures.
8Mar18 The pressures in the Work Item are correct
40 Technical
Para 4.1 states no GFM supplied. However, Para
7.6 states replace gearbox fluid with new GFM provided lube oil.
Please confirm if lube oil is provided GFM.
8Mar18 The ship will provide the oil
41 Technical
One of our subcontractors is requesting a full parts list of the components contained within the work specification. Can you please either provide the P/Ns or manual.
We do not have a copy of the NAVSEA Technical Manual T9593-AS-MMC-010, Titled “Sludge and Waste Incinerator, Model ASWI 402-AS” referenced in the WI.
8Mar18 These parts are not in the technical manual. They are in a technical buletin to be provided by the OEM authorized tech rep. However a copy of the manual is provided
42 0614 Missing ref docs. Please can we have the reference documents: '621-6241582' and '621- 6241581' for WI 0614.
8Mar18 Provided
43 0206 Paragraphs 6.1, 6.2 and 6.3 state that the work shall be performed to the satisfaction of the manufacturer’s technical field service representative. Can you confirm who this is and can you confirm if they are government furnished? There is no line that specifies the representative is to be furnished by the contractor.
8Mar18 A manufactures rep will not be required
44 0410 Subcontractor requires more information in order to quote, "need to understand the number of license, hardware, release details, so that we can provide a proposal" - Can you please provide more information on the installed telephone system?
8Mar18 The system release is CM 2.1 with S8700 servers. The number of licenses, estimate 150 lines/stations.
45 0508 Paragraph 7.2.6 'please provide model numbers for Filter Dryers'
8Mar18 873MS (2 needed). 90C01-1562-2 (4 needed).
46 0508 Paragraph 7.2.11 ' please provide detail of 8Mar18 15295-01 (2 needed). 15295-02 (2
Heating Trips to allow cost to be allocated' needed)
47 0609 We have been asked the following question by the supplier in order to be able to quote:
1-Model no of SCBA sets including face masks (QS, 90U or Spiroguide II) 2-Cylinders capacity: 9 ltr or 6.8 ltrs 3-Carbon composite or steel cylinders
8Mar18 1. Spiromatic HP 4500
2. 9 ltr
3. Composite
48 0407 Please confirm if current antenna pedestal is to be retained and re-used for the new installation of the 6011-4 Direct to Sailor TVRO Antenna
8Mar18 The antenna pedistal is to be replaced
49 0201 Subcontractor MAN Diesel have quoted a seven
(7) week lead time for certain ME spares (from placement of order) - please confirm that Contract Award will take afford enough time to place this and other contracts to ensure that there are no programme implications.
8Mar18
50 0614 Please provide NAVSEA Drg. #621-6241581 T/S Space Details & Accessories
8Mar18 Provided
51 0109 With respect to the definition for speciality metals in reference DFAR 252.225-7009, is it possible to provide grades of metals in addition to the alloy constituant parts.
8Mar18 Please review DFAR 252.225-7009
52 0905 Line 7.15.1 states "The contractor shall provide the services of an authorized manufacturer’s (Rolls Royce) field service engineer for the duration of this work item and during Dock and Sea Trials"
We have contact Rolls Royce, but they are ufamiliar with the CPP system - can you please advise?
12Mar18 You have contacted the wrong division of Rolls RoyceRolls Royce Marine see below 110 Norfolk Street Walpole, Massachusetts 02081 (USA) Tel - (508) 734-6326) Fax [Int. + (508) 734-2497) POC: Mr. Thomas Quinn/ Mr. Joe Beauvais
53 0610 Work item 610 - the manufacturer (Willard Marine) has recommended omitting line 7.1.12.1 "the compression test. The engines installed on these boats require extensive disassembly in order to perform a compression test and it is not advisable to tear an engine apart while it is still installed on the boat working in an open environment". Can you please advise.
12Mar18 Omit the compression test. However, the specification requires the boats to be removed to an inside work area.
54 0303 Work item 303 - no response received from daniel.enge@siemens.com the specified POC.
Can you please provide an alternative contact?
12Mar18 Bernd Reuter Sen. Field Service Engineer
RYNO ENTERPRISES
3730 E. Broadway, Suite D Long Beach, CA 90803 USA Tel: 562 433 7072, Fax: 562 433 9373 www.rynoenterprises.us
Siemens Energy & Automation Industry Solutions Division Attn.: Mrs. Regina Spivey 100 Technology Drive Alpharetta, GA 30005 Tel. (770) 740-3289 Fax. (770) 740-3598
55 0407 In order to establish the correct type of cabling to be installed, can you confirm if the length of the cabling from the Entertainment Room to the Antenna is:
1. Less than 150ft
2. More than 150ft but less than 250ft
3. Greater than 250ft
12Mar18 Specification requires reusing existing cable.
56 0615 Reference Clarification Response Number 13:
The Work Instructions states "Remove old sealer, and prepare the terrazzo flooring in paragraphs 3.1.2, 3.1.3, and 3.1.4 to be resealed." - there is no paragraphs referenced. Can you please confirm if this WI covers the galley, scullery and serving annex areas as mentioned in paragraph 1.1.
12Mar18 WI covers only the Toilet/Shower Terrazzo Decking of 3.1.1
57 0406 Reference Clarificaton Response Number 21:
Can you please provide the referenced email.
12Mar18 See question 58
58 Multiple MSC response 35 - "MSC can provide a list of contractors known to have the required qualification. However, The offeror is responsible for contacting and obtaining all subcontractor quotes. The Government does not assist any offeror with obtaining subcontractor quotes which support overall WI pricing."
Could you please provide this list - in particular we are struggling to obtain contractors with the required qualifications for the following WIs 905, 410, 406
8Mar18 WI 406 see question 30 WI 905 see question 52 WI 410 See below Dwight Denny, PMP East Coast Service Manager Avaya Federal Solutions Voice (919) 425-8343 dsdenny@avaya.com
Dave Maier West Coast Service Manager Avaya Federal Solutions Project Manager
(619) 851-3283 dmaier@avaya.com
Fadi Hani, Vice President, Middle East, Africa & Turkey Emirates Towers Office, Level 24, PO Box 72055 Dubai, United Arab Emirates fhani@avaya.com Phone 00971 4 404 8100 Fax 00971 4 4048140
Amal Ramou, PA to Vice President Emirates Towers Office, Level 24, PO Box 72055 Dubai, United Arab Emirates aramou@avaya.com Phone 00971 4 404 8100 Fax 00971 4 4048140
59 0021 Clean and Gas Free tanks - Kindly provide us vessel's arrival conditions, for our review.
8Mar18 Cargo Tanks will be clean and empty
60 0406 Remote switching control unit - Please provide makers details to submit our offer.
8Mar18 References provide adequate detail for bid
61 0407 T-AO Class orbit TV direct to sailor replacement - Please provide makers details to submit our offer.
8Mar18 References provided include adequate detail for bid submittal;
Model 6011 Direct to Sailor MS6011-4 Data sheet is readily available on the
INTERNET
62 0510 SSDG Tune up and Repair - Please find the comments from the OEM "Rolls Royce" - "Since the units are legacy, give us at least 2 weeks time in order to send you the spares quote and service quote
8Mar18 Acknowledged by Government Requiring Activity
63 0523 Gauge Calibration - Please provide the gauges list to submit our offer.
8Mar18 Provided
64 0610 Rescue Boat Recertification - Please provide boat hull number, engine type, serial numbers and running hours to submit our offer.
8Mar18 1. Hull Numbers RHIB #1:
WLD22075E414 RHIB #2:
WLD22077E414 2. Engine Serial Numbers RHIB #1: A283460 RHIB #2:
A283454
3. Engine Run Hours RHIB #1: 16 hrs RHIB #2: 17.4 Hrs
4. Engine Manufacturer: Willard Marine The remaining information is in the specification
65 Section M-2 Speciality Metal Certification of Origin - Please let us know, is it acceptable for submitting our material certificate
8Mar18 Only if your certificate meets the requirements of DFARS 252.225-7009
66 General Recommended Specialist subcontractors - Please be informed that we are still waiting for 85% of specialist subcontractor proposals. Due to this, we are requesting you to support us for obtaining the proposals from the specialist subcontractors in time.
8Mar18 MSC can provide a list of contractors known to have the required qualification. However, The offeror is responsible for contacting and obtaining all subcontractor quotes.
The Government does not assist any offeror with obtaining subcontractor quotes which support overall WI pricing.
67 General
Allow us to provide Generator 1250 Kva x 2 sets. 11Mar18 The Shore Power delivered to the ship must meet the requirements of WI 0011 and be reliable. The use of generators is acceptable as long as those requirements are met.
68 General
Being ASRY is a commercial shipyard, we have frequent vessel movements within the yard and laying oil containment boom will severely obstruct shipyard operations. ASRY has undertaken several USN vessels dry-docking and repairs, where the requirement for oil containment boom was not requested/required.
ASRY has in place emergency response action with respect to any accidental oil spill as per our safety protocol. We would therefore request USN for waiver / de-scope of this work item?
11Mar18 Omittion of the oil booms is acceptable as long as the contractor accepts responsibility for any conditions, situations, or damages arising from the oil booms not being in place.
69 0407 T-AO Class Orbit TV Direct to Sailor Replacement
- Please check response from supplier: Seatel TVRO 6011 is discontinued. Since it is for a US Navy vessel, which will certainly be sailing in American seas, one of the replacements can be SeaTel 120 TVHD. Data sheet for Seatel 120 TVHD attached for your ready reference.
11Mar18 SeaTel 120 is not compatable with existing equipment. Market research shows that the 6011-4-DTS, TVRO has not been discontinued.See below:
Tommy Waite Service manager Intech Marine Services 1226 Executive Blvd. Suite 113 Chesapeake Va. 23320 Office: 757.549.1143 Cell: 757.651.4443
Mid Atlantic Engineering Technical Services, Inc.
1501 Crossways Blvd. Ste. E Chesapeake, VA. 23320 Off: 757-512-6864 ext. 107 Cell: 757-284-6683 Fax: 757-410-0100 Email: bsmith@maets.net
Barney Cagle Navtech Marine Electronics 293 Kalihi Street Honolulu, Hi 96819-3938 barney.cagle@navtechmarine.com Tel: 1-808-848-7600 Cell: 1-808-429-4168
70 0503 Incinerator Maint and Repair - Please provide the existing drawings & manuals "T9593-AS-MMC- 010"
11Mar18 Provided in Amendment #5
71 0108 Focs'le Preservation - Please confirm, which type of paint application will be required either non-slip or non-skid, because in the specification, the paint application was mentioned non-slip type in point no. 1.1 & 7.8 and non-skid type in point no.
4.1.1 & 5.4.
8Mar18 The paint system will be Pedestrian Non-Slip
72 General Further to the requirement of clarification from your end and specialist subcontractors quote, we are requesting for extension in bid submission date to 22nd March 2018. Kindly grant us time till then
8Mar18 Proposal due date is being extended with Amendment 2 until 21 March 2018.
(End of Summary of Changes)