Coherent Data Sheet.pdf
PDF 2 MB Posted
- Attached to
- Two (2) Single-Channel Water/ Water Chillers
- Solicitation number
- N3239825Q8358
About this file
The document is a detailed product datasheet for Coherent's HighLight FL series of high-power multi-mode fiber lasers. The lasers are designed for industrial welding and cutting applications, offering output power ranging from 1,000 to 10,000 watts with exceptional stability and reliability. Key features include a multi-stage back reflection immunity system that enables safe processing of reflective materials like brass, copper, and aluminum, and flexible beam management through either a Fiber-Fiber-Switch (FFS) or Fiber-Fiber-Coupler (FFC) configuration.
The datasheet provides comprehensive technical specifications across multiple models, including electrical ratings, cooling requirements, fiber delivery system details, and mechanical specifications. Each model variant offers power range from 1-100%, laser beam quality metrics, and consistent power stability of ±1%. The lasers support various fiber diameters (50-400 µm), operate at a wavelength of 1070 ± 10 nm, and can be configured with optional interfaces like fieldbus communication, scanner control, and multi-station capabilities. Additional benefits highlighted include reliable and fast welding processes, high welding seam quality, and minimized operating costs.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Statement of Need Laser Chiller v2.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HighLight FL High-Power Multi-Mode Fiber Lasers with Beam Management The HighLightTM FL series of industrial, multi-kilowatt fiber lasers provides a cost-effective solution for many common welding tasks.
These lasers feature Coherent’s unique multi-stage back reflection immunity system which enhances reliability and lifetime, and enables safe processing of highly reflective materials, including brass, copper, and aluminum.
To maximize operational flexibility, HighLight FL products are equipped with either a Fiber-Fiber-Switch (FFS) or Fiber-Fiber-Coupler (FFC).
The FFS enables rapid switching of laser output between up to four separate process fibers, thus allowing time or energy sharing amongst four workstations with a single laser. The FFC allows easy exchange of process fibers on site.
FEATURES & BENEFITS
• Output power: 1,000 - 10,000 Watts
• Fiber-Fiber-Switch (FFS) or Fiber-Fiber-Coupler (FFC)
• Excellent stability over the entire power range (1% to 100%)
• Inherently back reflection safe
• Versatile production tool due to wide range of beam qualities
• Industry-leading closed loop power control for high process consistency
• Optimized power profile programming tool for welding processes
• CleanWeldTM technology to optimize welding results
BENEFITS
• Reliable and fast welding process
• High welding seam and welded part quality
• Minimized operating costs
APPLICATIONS
• Welding
• Cutting
HighLight FL Datasheet
SPECIFICATIONS HighLight FL1000 HighLight FL2000 Nominal Power (W) 1,000 2,000
Power Range (%) 1 - 100
Laser Beam Quality (BPP) at Collimator (mm x mrad)
50 μm: ≤ 2.5; 100 μm: ≤ 4; 150 μm: ≤ 6 200 μm: ≤ 8; 300 μm: ≤ 12; 400 μm: ≤ 16
Power Stability (%) ± 1
Pulse Frequency Range (kHz) CW - 10
Wavelength (nm) 1070 ± 10
ELECTRICAL RATINGS
Voltage (VAC) 400/440/480 ± 10%
Max. Connected Load (kVA) 4.4 7.1
Max. Effective Power at Nominal Laser Power at 400 V (kW)
4.2 6.9
Max. Current Consumption at 400 V (A) 6.1 9.9
Fuses Type NH (A) 16 32
COOLING
Recommended Cooling Capacity Laser (kW) 2.2 4.4
Recommended Cooling Capacity FFS/FFC and QHB/QD (kW)
FFS2: 1.0; FFS4: 1.5; FFC: 1.0
Flow Rate Laser (l/min) 21
Flow Rate for FFS/FFC and QBH/QD (l/min) FFS2: 8.0; FFS4: 12.0; FFC: 6.0
Temperature Laser (°C) 25 ± 1
Temperature for FFS/FFC and QBH/QD (°C) 24 - 40
Max. Pressure Laser (MPa) 0.5
Max. Pressure for FFS/FFC and QBH/QD (MPa) 0.4
Typical Pressure Drop Laser (MPa) 0.25
FIBER DELIVERY SYSTEM
Interface QBH/QD
Diameter (µm) 50 - 400
Length (m) 10, 15, 20, 30, 35 (other lengths on request)
DIMENSIONS & WEIGHTS
Laser Dimension L x W x H (mm) without signal tower
Midi: 794 x 1040 x 1067
Laser Weight (kg) FFC: < 400, FFS: < 450
ENVIRONMENTAL CONDITIONS
Ambient Temperature (°C) 5 - 40
Humidity (°C) Environmental conditions always below the dew point. Condensation to laser, QHB/QD and optics must be avoided during the operation, storage and transport.
CUSTOMER INTERFACE
Digital Signals (V DC) 24
Power Control (V DC) 0 - 10 V
Gate Control (V DC) 24, rise/fall time < 30 µs
OPTIONS LASER
Field bus (Ethernet/IP, Profinet, Profibus, Devicenet, Ethercat), Scanner control interface, Multi station interface
SPECIFICATIONS HighLight FL4000 HighLight FL5000 HighLight FL6000 Nominal Power (W) 4,000 5,000 6,000
Power Range (%) 1 - 100
Laser Beam Quality (BPP) at Collimator (mm x mrad)
100 μm: ≤ 4; 150 μm: ≤ 6; 200 μm: ≤ 8 300 μm: ≤ 12; 400 μm: ≤ 16
Power Stability (%) ± 1
Pulse Frequency Range (kHz) CW - 10
Wavelength (nm) 1070 ± 10
ELECTRICAL RATINGS
Voltage (VAC) 400/440/480 ± 10%
Max. Connected Load (kVA) 13.9 19.3 20.8
Max. Effective Power at Nominal Laser Power at 400 V (kW)
13.7 19.1 20.6
Max. Current Consumption at 400 V (A) 19.8 27.5 29.7
Fuses Type NH (A) 32 63
COOLING
Recommended Cooling Capacity Laser (kW) 8.9 11.1 13.3
Recommended Cooling Capacity FFS/FFC and QHB/QD (kW)
FFS2: 1.0; FFS4: 1.5; FFC: 1.0
Flow Rate Laser (l/min) 43 65
Flow Rate for FFS/FFC and QBH/QD (l/min) FFS2: 8.0; FFS4: 12.0; FFC: 6.0
Temperature Laser (°C) 25 ± 1
Temperature for FFS/FFC and QBH/QD (°C) 24 - 40
Max. Pressure Laser (MPa) 0.5
Max. Pressure for FFS/FFC and QBH/QD (MPa) 0.4
Typical Pressure Drop Laser (MPa) 0.25
FIBER DELIVERY SYSTEM
Interface QBH/QD
Diameter (µm) 100 - 400
Length (m) 10, 15, 20, 30, 35 (other lengths on request)
DIMENSIONS & WEIGHTS
Laser Dimension L x W x H (mm) without signal tower
Midi: 794 x 1040 x 1067
Laser Weight (kg) FFC: <460, FFS: < 520
ENVIRONMENTAL CONDITIONS
Ambient Temperature (°C) 5 - 40
Humidity (°C) Environmental conditions always below the dew point. Condensation to laser, QHB/QD and optics must be avoided during the operation, storage and transport.
CUSTOMER INTERFACE
Digital Signals (V DC) 24
Power Control (V DC) 0 - 10 V
Gate Control (V DC) 24, rise/fall time < 30 µs
OPTIONS LASER
Field bus (Ethernet/IP, Profinet, Profibus, Devicenet, Ethercat), Scanner control interface, Multi station interface
SPECIFICATIONS HighLight FL7500 HighLight FL8000 HighLight FL10000 Nominal Power (W) 7,500 8,000 10,000
Power Range (%) 1 - 100
Laser Beam Quality (BPP) at Collimator (mm x mrad)
100 μm: ≤ 4; 150 μm: ≤ 6; 200 μm: ≤ 8 300 μm: ≤ 12; 400 μm: ≤ 16
Power Stability (%) ± 1
Pulse Frequency Range (kHz) CW - 10
Wavelength (nm) 1070 ± 10
ELECTRICAL RATINGS
Voltage (VAC) 400/440/480 ± 10%
Max. Connected Load (kVA) 24.4 27.6 36.2
Max. Effective Power at Nominal Laser Power at 400 V (kW)
24.2 27.4 36
Max. Current Consumption at 400 V (A) 35 39.6 52
Fuses Type NH (A) 63
COOLING
Recommended Cooling Capacity Laser (kW) 16.7 17.8 22.2
Recommended Cooling Capacity FFS/FFC and QHB/QD (kW)
FFS2: 1.0; FFS4: 1.5; FFC: 1.0
Flow Rate Laser (l/min) 65 84
Flow Rate for FFS/FFC and QBH/QD (l/min) FFS2: 8.0; FFS4: 12.0; FFC: 6.0
Temperature Laser (°C) 25 ± 1
Temperature for FFS/FFC and QBH/QD (°C) 24 - 40
Max. Pressure Laser (MPa) 0.5
Max. Pressure for FFS/FFC and QBH/QD (MPa) 0.4
Typical Pressure Drop Laser (MPa) 0.25
FIBER DELIVERY SYSTEM
Interface QBH/QD
Diameter (µm) 100 - 400
Length (m) 10, 15, 20, 30, 35 (other lengths on request)
DIMENSIONS & WEIGHTS
Laser Dimension L x W x H (mm) without signal tower
Maxi: 794 x 1040 x 1565
Laser Weight (kg) FFC: <530, FFS: < 590
ENVIRONMENTAL CONDITIONS
Ambient Temperature (°C) 5 - 40
Humidity (°C) Environmental conditions always below the dew point. Condensation to laser, QHB/QD and optics must be avoided during the operation, storage and transport.
CUSTOMER INTERFACE
Digital Signals (V DC) 24
Power Control (V DC) 0 - 10 V
Gate Control (V DC) 24, rise/fall time < 30 µs
OPTIONS LASER
Field bus (Ethernet/IP, Profinet, Profibus, Devicenet, Ethercat), Scanner control interface, Multi station interface
1634837813E Highlight
1634837813E Highlight
1634837813E Highlight
1634837813E Highlight
1634837813E Highlight
1634837813E Highlight
1634837813E Highlight
1634837813E Highlight
1634837813E Highlight
1634837813E Highlight
1634837813E Highlight
MECHANICAL SPECIFICATIONS
Midi:
HighLight FL1000 - HighLight FL6000
• Verified dimensions FAI (First Article Inspection) and/or SPC
NOTE:
• Drawing must be used with 3D model. 3D is the master document and all shapes and dimensions must be according to 3D.
• Dimensions are for uncoated (blank) part, if not marked otherwise.
• All delivered parts (and assemblies) must be clean and burr free.
• Surface roughness is max Ra 6.3 µm, if not marked otherwise.
• All sharp edges should be removed for easy handling -edges and corners are allowed to have max R0.2mm if not marked otherwise.
• Tolerances according to SFS-EN 22768-1-m (linear and angular dimensions) and SFS-EN 22768-2-K (geometrical tolerances) (DIN ISO 2768-mK T1 and T2), if not marked otherwise.
Welding tolerances according to SFS-EN 13920-B and -F.
• Areas marked with ( or ) are class 1 surface area. Visible scratches, dents or other handling/ manufacturing defects are not allowed at class 1.
(Process follow up) are marked with numbered balloons.
can be added if needed for supplier process
MANUFACTURING MARKING NOTE:
Manufacturing marking is based on item code at title block:
1234567VV XY/FGH or PABCDE-VVV XY/FGH, where
• 1234567 or PABCDE is item code
• VV or -VVV is current item version
• XY is supplier name and location first letter
• /FGH is item serial number (running number) and tracking (like date, operator, testing etc.)
Restriction of Hazardous Substances in Electrical and
RoHS COMPLIANCE:
Used materials and components need to be RoHS compliant.
See latest EU Directive (
Electronic Equipment.
such as 2015/863/EU for "RoHS 3") for
SFS-EN 22768-2-K
3D MODEL
1:102D CODE-REV.
NAME DATE
2D DRAWING
APPROVED
1 / 2
ANY REPRODUCTION, IN WHOLE OR IN PART, WITHOUT A WRITTEN AUTHORIZATION OF COHERENT INC. (CORELASE OY) IS PROHIBITED.
ITEM NAME
SIZE A2
23.3.2020JLINITIAL CREATION
DIN ISO 2768-K T2
DIN ISO 2768-m T1
DIMENSIONS ARE IN mm (millimeter)
GENERAL TOLERANCES:
MACHINED
WELDED SFS-EN 13920-BF
SFS-EN 22768-1-m
SCALE
THE INFORMATION CONTAINED IN THIS DRAWING IS SOLE PROPERTY OF COHERENT INC. (CORELASE OY).
AND CONFIDENTIAL
23.3.2020
23.3.2020TK
23.3.2020JL
JL
ITEM CODE-REV. 1428471AA
3D CODE-REV.MATERIAL
SURFACE TREATMENT
DO NOT SCALE DRAWING
SHEET
PROPRIETARY
FI-33721 Tampere, FINLAND Kauhakorvenkatu 52
ARM-4xFFS Midi System Assembly
QD Cable
QD Cable Water IN
Water OUT QD Cable
QD Cable
Laser Water OUT (G1) Laser Water IN (G1)
Optics Water OUT (G1) Optics Water IN (G1)
G1/2
Coherent, Inc., 5100 Patrick Henry Drive Santa Clara, CA 95054
p. (800) 527-3786 | (408) 764-4983
f. (408) 764-4646 tech.sales@Coherent.com www.Coherent.com
Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.
Coherent offers a limited warranty for all HighLight Lasers. For full details of this warranty coverage, please refer to the Service section at www.Coherent.com or contact your local Sales or Service Representative.
MC-054-19-0M1119 Copyright ©2019 Coherent, Inc.
Coherent industrial lasers are designed in strict accordance with the respective safety regulations. We certify that each laser manufactured by our company complies with FDA Radiation Performance Standards, 21 CFR Subchapter J and with IEC 60825.
Warning labels as shown in the figure appear on each Coherent laser to indicate the respective classification.
HighLight FL Datasheet
MECHANICAL SPECIFICATIONS
Maxi:
HighLight FL75000 - HighLight FL10000
• Verified dimensions FAI (First Article Inspection) and/or SPC
NOTE:
• Drawing must be used with 3D model. 3D is the master document and all shapes and dimensions must be according to 3D.
• Dimensions are for uncoated (blank) part, if not marked otherwise.
• All delivered parts (and assemblies) must be clean and burr free.
• Surface roughness is max Ra 6.3 µm, if not marked otherwise.
• All sharp edges should be removed for easy handling -edges and corners are allowed to have max R0.2mm if not marked otherwise.
• Tolerances according to SFS-EN 22768-1-m (linear and angular dimensions) and SFS-EN 22768-2-K (geometrical tolerances) (DIN ISO 2768-mK T1 and T2), if not marked otherwise.
Welding tolerances according to SFS-EN 13920-B and -F.
• Areas marked with ( or ) are class 1 surface area. Visible scratches, dents or other handling/ manufacturing defects are not allowed at class 1.
(Process follow up) are marked with numbered balloons.
can be added if needed for supplier process
MANUFACTURING MARKING NOTE:
Manufacturing marking is based on item code at title block:
1234567VV XY/FGH or PABCDE-VVV XY/FGH, where
• 1234567 or PABCDE is item code
• VV or -VVV is current item version
• XY is supplier name and location first letter
• /FGH is item serial number (running number) and tracking (like date, operator, testing etc.)
Restriction of Hazardous Substances in Electrical and
RoHS COMPLIANCE:
Used materials and components need to be RoHS compliant.
See latest EU Directive (
Electronic Equipment.
such as 2015/863/EU for "RoHS 3") for
SFS-EN 13920-BFWELDED
APPROVED
1 / 2
ANY REPRODUCTION, IN WHOLE OR IN PART, WITHOUT A WRITTEN AUTHORIZATION OF COHERENT INC. (CORELASE OY) IS PROHIBITED.
ITEM NAME
SIZE A2
23.5.2019JLINITIAL CREATION
DIN ISO 2768-K T2
DIN ISO 2768-m T1
ITEM CODE-REV. 1426651AA
3D CODE-REV.MATERIAL
SURFACE TREATMENT
SFS-EN 22768-1-m
SCALE
THE INFORMATION CONTAINED IN THIS DRAWING IS SOLE PROPERTY OF COHERENT INC. (CORELASE OY).
AND CONFIDENTIAL
23.5.2019
23.5.2019TK
23.5.2019JL
JL
1:102D CODE-REV.
NAME DATE
2D DRAWING
DO NOT SCALE DRAWING
SHEET
PROPRIETARY
FI-33721 Tampere, FINLAND
3D MODEL
SFS-EN 22768-2-K
DIMENSIONS ARE IN mm (millimeter)
GENERAL TOLERANCES:
MACHINED
Kauhakorvenkatu 52
ARM-4xFFS System Assembly
Optics Water IN (G1)
Laser Water IN (G1) Laser Water OUT (G1)
Optics Water OUT (G1)
G1/2
80 737
Water OUT
Water IN QD Cable
QD Cable
QD Cable
794 929
QD Cable
File details come from the government source that posted it. Updated .