Revised J-2 CHAMBERS.xls
XLS spreadsheet 58 KB Posted
- Attached to
- Midterm Availability on USNS WASHINGTON CHAMBERS Federal contract opportunity
- Solicitation number
- N3220521R4221
About this file
This document contains a spreadsheet listing category A items for maintenance and repair of the USNS WASHINGTON CHAMBERS. The spreadsheet includes line items for work on hull structure, machinery and propulsion, electrical systems, communications and navigation aids, auxiliary machinery systems, outfitting and habitability, heating/ventilation/air conditioning, drydocking, and replenishment gear. Many line items are for inspections, tests, overhauls, and certifications to be performed annually or biennially. The related federal contract opportunity is a solicitation from the Department of the Navy Military Sealift Command for a midterm availability on the USNS WASHINGTON CHAMBERS. The solicitation includes an attached statement of work but provides no further details regarding response date, award date, pricing terms, or set-asides.
View the file
Other files for this federal contract opportunity
Show all 29
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Cat A Items
| CATEGORY “A” ITEMS | ||||||||||||
| GENERAL REQUIREMENT | PRIME Contractor | SUB Contractor | Govt Mandated Tech Rep / Sub | OTHER COSTS | TOTAL PRICE | |||||||
| ITEM NO. | TITLE CAT A ITEM | PRIME L/H | LABOR PRICE | MATERIAL PRICE | SUB L/H | LABOR PRICE | MATERIAL PRICE | Price | TOTAL LABOR HOURS | TOTAL MATERIAL | ||
| CATEGORY "A" | ||||||||||||
| 000 | GENERAL REQUIREMENTS | |||||||||||
| 001 | SCOPE GENERAL REQUIREMENTS AND DEFINITIONS | - 0 | $ - 0 | $0 | ||||||||
| 002 | Technical and Manufacturer's Representative | - 0 | $ - 0 | $0 | ||||||||
| 003 | Approach, Berth, and Mooring Requirements | - 0 | $ - 0 | $0 | ||||||||
| 004 | Testing and Quality Assurance | - 0 | $ - 0 | $0 | ||||||||
| 005 | Electrical Safety Procedure Requirements | - 0 | $ - 0 | $0 | ||||||||
| 006 | Heavy Weather Plan | - 0 | $ - 0 | $0 | ||||||||
| 007 | Cold Weather Plan | - 0 | $ - 0 | $0 | ||||||||
| 010 | Furnish Office for Office Management Team | - 0 | $ - 0 | $0 | ||||||||
| 011 | General Services for Ship | - 0 | $ - 0 | $0 | ||||||||
| 012 | Information Technology Services | - 0 | $ - 0 | $0 | ||||||||
| 013 | PROJECT PLANNING AND PRODUCTION STATUS MONITORING REPORTS | - 0 | $ - 0 | $0 | ||||||||
| 014 | Weight and Movement Report | - 0 | $ - 0 | $0 | ||||||||
| 015 | Integrated Logistics and GFM Support Requirements | - 0 | $ - 0 | $0 | ||||||||
| 016 | Fire Protection and Ship's Safety Program | - 0 | $ - 0 | $0 | ||||||||
| 017 | Handling Ships Stores | - 0 | $ - 0 | $0 | ||||||||
| 018 | Delivery and Re-Delivery of the Vessel | - 0 | $ - 0 | $0 | ||||||||
| 019 | Shipboard Access and Security | - 0 | $ - 0 | $0 | ||||||||
| 020 | Gas Free Certificates | - 0 | $ - 0 | $0 | ||||||||
| 021 | Clean and Gas Free Tanks, Voids, Cofferdams and Spaces | - 0 | $ - 0 | $0 | ||||||||
| 022 | Machinery Space Turn-over, Dock Trials and Sea Trial | - 0 | $ - 0 | $0 | ||||||||
| 023 | Hazardous Waste Disposal at a Contractor's Facility | - 0 | $ - 0 | $0 | ||||||||
| 024 | Physical Security at Private Contractor's Facility | NSP | NSP | NSP | NSP | NSP | NSP | NSP | NSP | NSP | NSP | NSP |
| 090 | Daily COVID-19 Prevention and Control Services | - 0 | $ - 0 | $0 | ||||||||
| 100 | HULL STRUCTURE | |||||||||||
| 101 | Handrail Replacement | - 0 | $ - 0 | $0 | ||||||||
| 102 | Kick Pipe Replacement | |||||||||||
| 103 | Ladder_ladder Tab Repair | - 0 | $ - 0 | $0 | ||||||||
| 104 | Scaffolding to Support Ship's Force Preservation | - 0 | $ - 0 | $0 | ||||||||
| 107 | ROLLER CURTAIN DOOR REPAIR | |||||||||||
| 108 | Shore Power H Frame Fabrication | - 0 | $ - 0 | $0 | ||||||||
| 109 | Various Weatherlock Gauge Board Repair | |||||||||||
| 112 | Station 5 King Post Repair | |||||||||||
| 167 | Replace Hanger Roller Curtain Interlock Switch (TALT 199) | - 0 | $ - 0 | $0 | ||||||||
| 200 | MACHINERY, PROPULSION | |||||||||||
| 204 | TAKE_CSI_A_MDE CONTROL SAFETY INSPECTION AND TEST (1YR) (SCSI) | - 0 | $ - 0 | $0 | ||||||||
| 205 | TAKE_CSI_A_AUTOMATION AND PROPULSION CONTROL INSPECTION AND TESTING (1YR)(SCSI) | - 0 | $ - 0 | $0 | ||||||||
| 206 | TAKE_CSI_A_VULKAN COUPLING INSPECTION | - 0 | $ - 0 | $0 | ||||||||
| 211 | TAKE_CSI_MAIN ENGINE 8 CYLINDER SERVICE(36KHRS)(SCSI | - 0 | $ - 0 | $0 | ||||||||
| 300 | ELECTRICAL | |||||||||||
| 301 | Motor Overhaul | - 0 | $ - 0 | $0 | ||||||||
| 302 | Degaussing System Groom | - 0 | $ - 0 | $0 | ||||||||
| 305 | TAKE_CSI_A_PLC SURVEY (2YR) | - 0 | $ - 0 | $0 | ||||||||
| 322 | Consilium CS3000 Control Panel Upgrade (T-ALT 469) Rev- | - 0 | $ - 0 | $0 | ||||||||
| 353 | THERMOGRAPHIC SURVEY TAKE CCSI (1YR) | - 0 | $ - 0 | $0 | ||||||||
| 400 | COMMUNICATION AND NAVIGATIONAL AIDS | |||||||||||
| 401 | PUBLIC AND GENERAL ANNOUNCING SYSTEM PM AND REPAIRS | - 0 | $ - 0 | $0 | ||||||||
| 403 | COMMS SYS PM REV - | - 0 | $ - 0 | $0 | ||||||||
| 451 | TAKE_CCSI_A_ANNUAL RADAR SERVICE | - 0 | $ - 0 | $0 | ||||||||
| 452 | Annual ECDIS Service (SCSI) (CCSI) | - 0 | $ - 0 | $0 | ||||||||
| 453 | TAKE_CCSI_ANNUAL GYRO SYSTEM | - 0 | $ - 0 | $0 | ||||||||
| 454 | TAKE_CCSI_ANNUAL VDR RECERTIFICATION | - 0 | $ - 0 | $0 | ||||||||
| 455 | TAKE_CCSI_ANNUAL RADIO COMMUNICATION EQUIPMENT RECERTIFICATION | - 0 | $ - 0 | $0 | ||||||||
| 456 | TAKE_CCSI_MAGNETIC COMPASS SERVICE (2 YR) | |||||||||||
| 459 | ECHO SOUNDER SERVICE (1YR)_TAKE_CCSI | |||||||||||
| 460 | TAKE_CCSI_A_ANNUAL INSPECTION OF MANUALLY OPERATED ALARMS | - 0 | $ - 0 | $0 | ||||||||
| 500 | MACHINERY, AUXILIARY SYSTEMS | |||||||||||
| 504 | Bergan Console and System Groom | - 0 | $ - 0 | $0 | ||||||||
| 506 | TAKE_CSI_EMERGENCY DIESEL GENERATOR -ANNUAL TESTING AND INSPECTION (1 YR) (SCSI) | - 0 | $ - 0 | $0 | ||||||||
| 512B | TAKE_CSI_MAGAZINE SPRINKLER GAUGE SPRINKLER CALIBRATION - T11-14 | - 0 | $ - 0 | $0 | ||||||||
| 520 | CPVC Weather Deck Drains | - 0 | $ - 0 | $0 | ||||||||
| 521 | INCINERATOR INSPECTION AND MAINTENANCE | - 0 | $ - 0 | $0 | ||||||||
| 540 | TAKE_CSI_A_Cargo Crane Inspection (1YR)(SCSI) | - 0 | $ - 0 | $0 | ||||||||
| 554 | TAKE_CCSI_A_INSPECT TEST AND CERTIFY MACHINERY SPACE CRANES AND HOISTS (1YR) | - 0 | $ - 0 | $0 | ||||||||
| 557 | ANCHOR WINDLASS ANNUAL INSPECTION | - 0 | $ - 0 | $0 | ||||||||
| 561 | TAKE_CCSI_A_GAUGE CALIBRATION (1YR) | - 0 | $ - 0 | $0 | ||||||||
| 562 | TAKE_CCSI_A_SCBA ANNUAL INSPECTION (1) | |||||||||||
| 563 | SCBA Compressor and Filling Station Inspection and Maintenance (1YR) (CCSI) | - 0 | $ - 0 | $0 | ||||||||
| 565 | Fixed Gas Firefighting System Inspection and test (1YR) (SCSI (CCSI) | - 0 | $ - 0 | $0 | ||||||||
| 567 | Fixed Foam FireFighting System Inspection and test (1YR) (SCSI (CCSI) | - 0 | $ - 0 | $0 | ||||||||
| 569 | Fire and Smoke Detection and Alarm System (1YR) (SCSI) (CCSI) | - 0 | $ - 0 | $0 | ||||||||
| 570 | TAKE CCSI Portable Fire Extinguisher Service(1YR) (CCSI) | - 0 | $ - 0 | $0 | ||||||||
| 571 | TAKE CCSI Fire and Smoke Damper Service (1YR) (SCSI) (CCSI) | - 0 | $ - 0 | $0 | ||||||||
| 572 | TAKE CCSI Deep Fat Fryer and Range Hood Fire Extinguisher System (1YR) (SCSI) (CCSI) | - 0 | $ - 0 | $0 | ||||||||
| 573 | Fire Hoses (1YR) (CCSI) | - 0 | $ - 0 | $0 | ||||||||
| 574 | TAKE_CCSI_A_FIRE DOORS AND SHUTTERS_(1YR) | |||||||||||
| 575 | TAKE_CSI_WATER MIST FIREFIGHTING SYSTEM - INSPECTION AND TEST (1 YR) (SCSI) | |||||||||||
| 578 | TAKE_CSI_A_HELO HANGAR CRANE LOAD TESTING (4YR) | |||||||||||
| 579 | PIPING REPAIR | |||||||||||
| 600 | OUTFIT, FURNISHINGS AND HABITABILITY | |||||||||||
| 602 | Shower_Head Deck | - 0 | $ - 0 | $0 | ||||||||
| 603 | Kettle Deck Preservation | - 0 | $ - 0 | $0 | ||||||||
| 605 | Miscellaneous Lagging Repairs | - 0 | $ - 0 | $0 | ||||||||
| 610 | GALLEY EQUIPMENT CALIBRATION | - 0 | $ - 0 | $0 | ||||||||
| 643 | TAKE_CSI_A_CERTIFICATION OF SPIDER MAN BASKETS (1YR) | - 0 | $ - 0 | $0 | ||||||||
| 651 | TAKE_CCSI_A_ANNUAL LIFEBOAT AND DAVIT INSPECTION (ABS) | - 0 | $ - 0 | $0 | ||||||||
| 653 | TAKE_CCSI_A_ANNUAL FAST RESCUE BOAT AND DAVIT INSPECTION (ABS) | - 0 | $ - 0 | $0 | ||||||||
| 656 | TAKE_CCSI_ANNUAL LIFE RAFT CERTIFICATION | |||||||||||
| 657 | Accomadation Ladder Inspection (1YR) (CCSI) | - 0 | $ - 0 | $0 | ||||||||
| 662 | TAKE_CCSI_A_DEEP FAT FRYER INSPECTION (1YR) | - 0 | $ - 0 | $0 | ||||||||
| 800 | HEATING, VENTILATION, AND AIR CONDITIONING | |||||||||||
| 802 | Cargo and AC Plant Insp and Groom | - 0 | $ - 0 | $0 | ||||||||
| 803 | Overhaul Main Space Ventilation Fan and Dampers | |||||||||||
| 851 | TAKE_CCSI_A_GALLEY VENT AND GAYLORD HOOD CLEANING | |||||||||||
| 852 | TAKE_CCSI_ANNUAL LAUNDRY EXHAUST VENT CLEANING | - 0 | $ - 0 | $0 | ||||||||
| 900 | DRYDOCKING AND UNDOCKING | |||||||||||
| 958 | TAKE_CCSI_A_PROPELLER CLEAN AND POLISH - IN WATER_(0.5YR) | |||||||||||
| 1000 | UNREP GEAR | |||||||||||
| 1001 | HAULING WINCH BAND BRAKE REFURBISHMENT | - 0 | $ - 0 | $0 | ||||||||
| 1002 | Winch Control (Controlex) Riser | - 0 | $ - 0 | $0 | ||||||||
| 1003 | Gypsy Winch Preservation_Specification | - 0 | $ - 0 | $0 | ||||||||
| - 0 | $ - 0 | $0 | ||||||||||
| - 0 | $ - 0 | $0 | ||||||||||
| - 0 | $ - 0 | $0 |
&LUSNS ARCTIC (T-AOE 8)&CCONTRACTOR PRICE BREAKDOWN
&"Arial,Bold"CATEGORY "A" ITEMS&RN32205-19-R-6012
&CATTACHMENT J-2
File details come from the government source that posted it. Updated .