Questions_ Answers N3220521Q2246.pdf

PDF 419 KB Posted

Attached to
Wartsila Tail Shaft Repair
Solicitation number
N3220521Q2246
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RFQ Solicitation N3220521Q2246

Questions & Answers

Q1) Paragraph 7.9 of the work spec states, “Contractor shall install fiberglass coating IAW Naval

Standard MIL-STD 2199B and perform spark test to satisfaction of MSCREP and ABS surveyor”. Please confirm that MSC actually wants this Mil standard used.

A1) Yes, please utilize MIL-STD -2199B. (SAA)

Q2) The PWS states that the shaft is to be picked up from the MSC Charleston storage yard. Can you please confirm the address of that location and if we will need to have a crane to pick it up?

A2) Yes; Delivery address is as follows: (SAA)

N68779 MSCO Charleston 1050 Remount rd. NWS South N. Charleston, SC 29406 *POC : Tracy Carrington 757-803-4613

File details come from the government source that posted it. Updated .