REQUEST FOR SPECIFICATION CLARIFICATION
N32205-18-R-4005
USNS GUADALUPE (T-AO 200) MTA
NAME OF CONTRACTOR:
SPECIFICATION ITEM NO.: 0204
PARAGRAPH / SECTION NO: 7.0, 2.1
TITLE: MAIN REDUCTION GEAR INSPECTION
QUESTION:
In accomplishment of the work item inspection requirements, it will be necessary to drain the gear boxes and refill upon completion. Please provide reference 2.1.1 and gearbox capacity and oil type.
ANSWER:
Tech manualT9241-AL-MMC-010 is attached, which will provide gearbox capacity and oil type.