RFC QUESTION 0006 RE Enclosure 2.1 Para 7.5.2

View the file

Other files

File Type Posted
J A_mod_4_Redacted.pdf PDF
J A_REDACTED.pdf PDF
DD254_USNS_CHARLES_DREW.pdf PDF
ADDING_ATTACHMENT_J-15_DD254.docx DOCX document
RFC_0017-0021.doc DOC document
CHARLES_DREW_ROH-DD_JA_3_9_15_MOD_1.docx DOCX document
Amendment_0002.docx DOCX document
RFC_0015-0016.doc DOC document
RFC_0007-0014.doc DOC document
RFC_0004.doc DOC document
RFC_J_8_Request_for_Spec_.doc DOC document
RFC__002_-_Extension_request_adr_20Feb2015.doc DOC document
RFC_0001_J_-_13_PAST_PERFORMANCE_QUESTIONNAIRE_FBO.doc DOC document
J_-_13__PAST_PERFORMANCE_QUESTIONNAIRE.docx DOCX document
N32205-15-R-3002_REV_1.docx DOCX document
J_-_8_Request_for_Spec_Clarification.doc DOC document
J_-_14_Technical_Data_Non-Disclosure.docx DOCX document
J_-_9_Disclosure_of_Lobbying_Activities_SF-LLL.doc DOC document
DREW_J A_1_REDACTED.PDF PDF
J_-_6_WI_015_CDRL.pdf PDF
J_-_12_Past_Performance_Data.doc DOC document
J_-_2_Category_A_Items.xls XLS spreadsheet
J_-_4_GFP.xlsx XLSX spreadsheet
J_-_3_Category_B_Items.xlsx XLSX spreadsheet
J_-_10_Interport_Differential_West_Coast.doc DOC document
J_-_11_Dry_Dock_Evaluation_Form.docx DOCX document
N32205-15-R-3002_FINAL.docx DOCX document
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BAE SYSTEMS

SAN FRANCISCO SHIP REPAIR

USNS CHARLES DREW (T-AKE 10)

N32205-15-R-3002

REQUEST FOR SPECIFICATION CLARIFICATION # 006

NAME OF CONTRACTOR: BAE Systems Ship Repair

SPECIFICATION ITEM NO.: __402______________

PARAGRAPH / SECTION NO: Enclosure 2.1 & Para # 7.5.2_

TITLE:

QUESTION: Spec requires contractor to disconnect the antennas designated in enclosure 2.1…There are 55ea antennas in enclosure 2.1 however there are apprx. 6ea that have yellow highlights…Does contractor remove all the antennas in the enclosure or just the 6ea with the yellow highlights ?

Please advise

ANSWER:

Contractor shall disconnect, remove, and overhaul the antennas listed under Paragraph 3.2 and use reference 2.1 as guidance for their actual location on the ship.