Statement of Work

APN7-16 Requirement

BS-650013.APN7METCA94- RES/IMPED CALSTDS

A. Background

The use of NAVAIR METCAL equipment funding is to procure Calibration Standards (CALSTDs) and ancillary equipment for Aviation Fleet Intermediate Calibration Activities, Fleet Training Activities and Aviation Navy

Calibration Laboratories (NCLs) to support Aviation Organizational and Intermediate (I) level maintenance assets.

All Cal Standards listed for procurement must first go through an approval process. This process includes: initial submission by the fleet; review and prioritization by the Fleet TYCOM’s; laboratory workload justification and standardization review by a NAVAIR METCAL technical review team; overall procurement strategy review to assess overall program objectives, priorities and funding.

REQUIREMENTS:

1. Mfr. one year warranty with a warranty certificate.

2. Calibration Certificate and calibration sticker (as applicable for each unit)

3. Units shall be serialized.

4. Include shipping to destination below.

5. Manufacturer’s Standard Operating and servicing manuals (CD version acceptable) shall be provided with each unit.

B. Tasking:

The contractor shall provide the following equipment:

1) P/N 5300-S3412A SYNCHRO/RESOLVER STD,PROG Qty 25

To include the following:

a) Reference input:

a. Operating frequency range:

i. Synchro Mode: 60Hz to 1 kHz

ii. Resolver Mode: 360 Hz to 1 kHz

b. Voltage Range:

i. 60Hz to 1 kHz

ii. 2 to 115 V

c. Input impedance: 200 kohms minimum

d. Reference output:

e. Voltage range vs frequency:

i. 30 Hz to 1 kHz

ii. 2 to 115 V

f. Output impedance: <0.25 ohms

g. Voltage accuracy: +/-3% of setting

h. Voltage resolution: 3 digits

i. Output Current:

i. 2 to 26 V

ii. 100mA maximum

iii. >26 to 115 V

iv. 25 mA maximum

j. DC offset: 5 mV Maximum

k. Phase shift range: 0 to +/-180° to 0.001° resolution

l. Phase shift accuracy:

i. 60 to 1 Khz

ii. +/-0.5°

b) Outputs isolated:

a. Voltage accuracy: 2% of setting

b. Voltage resolution: 1% of setting minimum

c. DC offset” 5 mV maximum

d. Voltage range line to line: 1 to 90 V

e. Angular accuracy vs F:

i. 60 Hz - +/-0.000833°

ii. 400Hz - +/-0.0005°- 0.0000833°

iii. 400Hz - +/-0.00055°

iv. 400Hz - +/-0.00055°

v. 800Hz - +/-0.00055°

f. Other frequencies and V combinations:

i. +/-0.011°- +/- 0.000833°

g. Angular resolution: 0.0001° (0.36 arc-sec)

h. Output drive capability:

i. 2 to 26 V- 4VA max limited to 330 mA max

j. >26 to 90 V- 4VA max limited to 33 mA max

k. Output impedance (max):

i. 60 to 1kHz -<0.25 ohms

l. Radius (sinusoidal accuracy): +/- 0.005% typical

c) Dynamic angular modulation

a. Continuous (CW or CCW): to 100,000° (278rps)

b. Cyclical: sine triangle or square wave to 1 kHz or between preset angle

c. Incremental: successive equal angles on command

d) Other:

a. Front panel control: Push buttons: rotary control for manual angular positioning

b. Remote control: IEEE-488

c. Dimensions: 19”w x 3.5”h x 18 7/16” d bench or racking

d. Power: 115/220 VAC +/-10%, 47 to 440 Hz, 115 VA

e) Line cord

f) 115V line fuse

g) 230V line fuse

h) Rack mounting handles and hardware

C. Deliverables

Delivery of the equipment shall be provided at the following address:

NAVAIR Calibration Standards

MCAS, Attn: Lou Cerrillo

(UIC N48535)BLDG 612, Bay 9

Beaufort, SC 29904-5002

D. Delivery Date

Delivery shall be no later than 18 weeks after award of contract.

E. Invoicing