Statement of Work
NAVAIR Patuxent River 4.3.4.6. Corrosion and Wear Lab
Environmental Sensor Node
Location:
Materials Engineering Division
NAVAIR 4.3.4.6 – Corrosion and Wear Branch
Corrosion and Wear Lab – Room 206
48066 Shaw Road Unit 5 – Building 2188
Patuxent River MD, 20670-1908
TPOC – Victor Rodriguez-Santiago (301-342-8040) (victor.rodriguezsant@navy.mil) Equipment Needed:
1. Twenty five (25) environmental sensor nodes with the following characteristics:
LS2A-485 (Wired) Sensor Node. The sensor node shall:
· Read and store relative humidity and air temperature data
· Read and store surface temperature data
· Read and store condensate conductance data
· Corrosion rate (AA7075-T651)
· Shall have wired RS-485 interface
· The sensor node shall be self-powered and with on-board data acquisition capabilities, without the need of external power or external data storage.
· Shall include three (3) LS24-485 Data Acquisition Cables
· Shall include three (3) LS2a Charging Modules
2. NAVAIR will share with LUNA Innovations the data generated by the sensors. LUNA will utilize the data to evaluate the performance of the sensors. LUNA shall not distribute or publish the data without approval by NAVAIR.
3. The failure rate of the sensors (including battery, data retrieval, internal components, and sensing elements) shall not exceed 10%. If the failure rate exceeds 10%, the contractor shall reimburse the government for the lost equipment.
The lead time for delivery is 30 days ARO.