Attachment 3
1. Question:
In regards to the technical requirement of paragraph 1.1 of the SOW in solicitation N0016420RJM40, is the battery to be tested going to be a single battery pack made up of 40-48 cells, or is it 40-48 individual battery cells that will need to be tested simultaneously? In other words, will the test system need to consist of just a single test channel or 48 separate test channels?
Answer:
The battery to be tested is going to be a single battery pack made up of 40-48 cells. The Battery Test System needs to consist of just a single test channel.
2. Question:
The pre-solicitation (back in May timeframe) stated 270 Calendar days after receipt of funded order.
I now see 154 days in the more recent solicitation.
Can you confirm if this change was made appropriately, and if so, for what reason this deadline has been changed?
Answer:
The solicitation has been changed from 154 days to 270 Calender days after receipt of funded order to be in accordance with the synopsis.
File details come from the government source that posted it. Updated .