Attachment 3

1. Question:

In regards to the technical requirement of paragraph 1.1 of the SOW in solicitation N0016420RJM40, is the battery to be tested going to be a single battery pack made up of 40-48 cells, or is it 40-48 individual battery cells that will need to be tested simultaneously? In other words, will the test system need to consist of just a single test channel or 48 separate test channels?

Answer:

The battery to be tested is going to be a single battery pack made up of 40-48 cells. The Battery Test System needs to consist of just a single test channel.

2. Question:

The pre-solicitation (back in May timeframe) stated 270 Calendar days after receipt of funded order.

I now see 154 days in the more recent solicitation.

Can you confirm if this change was made appropriately, and if so, for what reason this deadline has been changed?

Answer:

The solicitation has been changed from 154 days to 270 Calender days after receipt of funded order to be in accordance with the synopsis.