Modular Patch Panel Specifications.docx

DOCX document 15 KB Posted

Attached to
Open Market Small Purchase IL|27-350SOS-ITSOS-P-102790
Contract number
27-350SOS-ITSOS-P-102790
Issued by
Illinois

About this file

This document is a technical specifications sheet for modular patch panel equipment. While the document does not explicitly identify a specific contracting state, agency, or consortium, it serves as a detailed product specification guide that would typically support a state or local government procurement related to network infrastructure or telecommunications equipment.

The document outlines comprehensive specifications for modular patch panel systems, including physical dimensions, port configurations, cable management features, and performance standards. Key specifications include panel size requirements, port density options, color coding standards, and compatibility requirements with existing network infrastructure. The document addresses material composition, durability standards, and installation requirements to ensure interoperability with standard data center and telecommunications equipment. No pricing information, contract amounts, option periods, set-asides, or renewal terms are specified in this technical specifications document, as it functions primarily as an equipment standard reference rather than a complete contract award document. This specification sheet would typically be incorporated by reference into a broader procurement solicitation or purchase order to ensure vendors meet required technical standards.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ITEM: Modular, unshielded 48-Port Patch Panel Specifications:

*Depth, with cable management 7.00 in Height 88.90 mm | 3.50 in *Width 482.60 mm | 19.00 in *Electrical Specifications-ANSI/TIA Category 3 | 5 | 5e | 6 | 6A *Flammability Rating: UL 94 V-0 *Operating Temperature: -10 degrees Celsius to +60 degrees Celsius (+14F to +140F) *Relative Humidity: Up to 95%, non-condensing *Safety Standard: cUL UL *Storage Temperature: -40 degrees Celsius to +70 degrees Celsius (-40F to +158F) *Type: Passive, Panel, Modular *Total Ports: 48 *Color: Black *Rack Type: EIA 19 in *Rack Units: 2 *Material Type: High-impact, flame retardant, thermoplastic, powder-coated steel *Regulatory Compliance/Certifications: RoHS 2011/65/EU Compliant, ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system