JA-3_A_Drawings_11x17.pdf
PDF 10 MB Posted
- Attached to
- Install CAC Overhead Door Eielson AFB Federal contract opportunity
- Solicitation number
- MELLO-FTQW132405-CAC-DOOR
About this file
JA-3 A Drawings 11x17
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amend_0002_(Bid_Due_Date_Ext.).doc | DOC document | |
| Questions_and_Answers.docx | DOCX document | |
| FA5004-15-B-C009-0001.pdf | ||
| JA-7_AF_Form_3064.pdf | ||
| JA-1_Statement_of_Work.pdf | ||
| JA-2_Specifications.pdf | ||
| FA5004-15-B-C009 _CAC_Overhead_Doors_Solicitation.pdf | ||
| JA-3_B_Drawings_22x34.pdf | ||
| JA-6_AF_Form_3000.pdf | ||
| JA-9_Financial_Reference_Sheet.pdf | ||
| JA-8_AF_Form_3065.pdf | ||
| JA-4_Wage_Determination_Building_and_Heavy_AK1.pdf | ||
| JA-5_AF_Form_66.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G
JA-3 A Drawings 11x17
FA5004-15-B-C009
LOCATION MAP VICINITY MAP
PROJECT
G000 G001 G002
601 COLLEGE ROAD FAIRBANKS,
ALASKA 99701
(907) 452-1241 designalaska.com
DESIGN ALASKA
A001 A101 A201 A401 A801
TYPICAL ABBREVIATIONS & SYMBOLS
FIRST FLOOR PLAN - DEMOLITION
FIRST FLOOR PLAN - RENOVATION
WALL SECTIONS
DETAILS
COVER SHEET
DRAWING INDEX, MAPS AND CODE
PROJECT LOCATION
SEE VICINITY MAP
DESIGN ANALYSIS
GOVERNING CODES
2012 INTERNATIONAL BUILDING CODE
2014 NATIONAL ELECTRICAL CODE
BUILDING CLASSIFICATION: *S-1 - STORAGE GROUP
TYPE OF CONSTRUCTION: IIB
SPRINKLER PROTECTION: YES - DELUGE SYSTEM
AUTHORITY HAVING JURISDICTION
EIELSON AIR FORCE BASE
*CURRENT AIRCRAFT HANGAR STORAGE AND REPAIR IS CLASSIFIED
AS S-1 OCCUPANCY, CONVERSION OF BAY 3 TO FIRE APPARATUS
STORAGE AND REPAIR IS CLASSIFIED AS S-1 OCCUPANCY.
ALLOWABLE BUILDING AREA: 17,500 + 13,125 + 0 = 30,625
ALLOWABLE STORIES: 2
ALLOWABLE HEIGHT: 55 FEET
ACTUAL BUILDING AREA: 21,500
ACTUAL STORIES: 1
ACTUAL HEIGHT: 33 FEET
REQUIRED EXITS: 3,127/200 = 16 OCCUPANTS
No. OF EXITS REQUIRED 1 No. OF EXITS PROVIDED 1
TRAVEL DISTANCE 200 FEET WITHOUT SPRINKLER
ACTUAL TRAVEL DISTANCE 98 FEET
DESIGN TEAM
DRAWING INDEX
S001 S100 S200 S201
GENERAL STRUCTURAL NOTES
DEMOLITION DETAILS
STRUCTURAL WALL ELEVATION AND DETAILS
FRAMING DETAILS
E100 ELECTRICAL SYMBOL LEGEND, PLANS &
SCHEDULES
H100 HAZMAT PLAN
PASS THROUGH GATE
SHALL REMAIN CLOSED
AT ALL TIMES
EIELSON AFB MAP
H
1 GRAY PAINT ON HOUSING FOR MOTOR AND BLACK PAINT AT
MOTOR SUPPORTS CONTAIN LEAD BASED PAINT.
2 BLACK PAINT AT FRAME OF HANGAR DOOR CONTAINS LEAD
BASED PAINT.
1/8"=1'-0"
3 BLACK PAINT AT FRAME OF MAN DOOR CONTAINS LEAD BASED
PAINT.
4 YELLOW STRIPING ON PAVEMENT CONTAINS LEAD BASED
PAINT.
NO WORK THIS AREA
2 2
1. GRAY FIRE PROOFING AT NORTH WALL IDENTIFIED
NEGATIVE FOR ASBESTOS CONTAINING MATERIALS.
2. ALL AREAS AFFECTED BY WORK NOT INDICATED TESTED
NEGATIVE FOR LEAD BASED PAINT. SEE HAZARDOUS
MATERIALS ASSESSMENT.
3. COMPLETE HAZARDOUS MATERIALS ASSESSMENT FOR
FTQW 13-2405 IS ATTACHED.
A
1. OWNER TO REMOVE LOCKERS, FURNISHING, EQUIPMENT
PRIOR TO CONSTRUCTION.
2. PER RECORD DOCUMENTS AND FIELD INSPECTION, BAY 3
HANGAR DOOR ASSEMBLY CONSISTS OF: 24 GAUGE
CORRUGATED METAL PANELS OVER WIDE FLANGE
VERTICAL BEAMS WITH 2X WOOD NAILERS AT
APPROXIMATELY 48 INCHES O.C. HORIZONTALLY BETWEEN
STEEL. CAVITY IS FILLED WITH BATT INSULATION.
INTERIOR FINISH IS CORRUGATED METAL PANELS OVER
POLYETHYLENE VAPOR RETARDER ON WOOD NAILERS.
3. EAST WALL AND EAST HANGAR DOOR NOT IN SCOPE OF
WORK. EXISTING HANGAR DOOR IS NOT CAPABLE OF
OPENING.
4. WEST HANGAR DOOR IS NOT FULLY OPERATIONAL. DOOR
OPERATION WILL RAISE DOOR BOTTOM TO
APPROXIMATELY 5 FEET MAXIMUM ABOVE HANGAR SLAB.
5. WORK AREA EXTENDS TO THE JOINED OPERATING
SYSTEMS FOR BAY 3 & 4. OPERATING SYSTEM TO BE
REMOVED IS CONNECTED THROUGH WALL TO BAY 4
OPERATING SYSTEM. SEE SHEET S100 FOR STRUCTURE,
EQUIPMENT AND ACCESSORIES TO REMAIN IN PLACE FOR
BAY 4 TO REMAIN FULLY OPERATIONAL.
1 EXISTING CONCRETE COUNTERWEIGHT HAS BEEN LOWERED
TO HANGAR FLOOR.
2 EXISTING FIRE PUMP TEST APPARATUS TO REMAIN.
1/8"=1'-0"
3 REMOVE HANGAR DOOR AND DOOR OPENING SYSTEM
INCLUDING, BUT NOT LIMITED TO; DOOR, SHEAVES, TRACKS,
GUIDE ROLLERS, WIRE ROPE, MOTOR, CONTROL, ETC. CLEAN
AND PREPARE AREA FOR INSTALLATION OF NEW WORK. SEE
STRUCTURAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
DEMOLITION WORK.
4 REMOVE EXISTING CONCRETE COUNTER WEIGHT, FRAME,
ENCLOSURE AND ALL RELATED ACCESSORIES.
5 REMOVE MOTOR, OPERATOR, ENCLOSURE, CONCRETE PAD,
FLOOR MOUNTED BEAM, CONTROL PANEL, AND ALL RELATED
ACCESSORIES.
6 EXISTING CONCRETE RAMP TO REMAIN.
7 EXISTING DOOR TO REMAIN.
8 APPROXIMATE AREA OF BAY 4 SHARED DOOR OPERATING
SYSTEM, FLOOR TO CEILING. BAY 4 TO REMAIN FULLY
OPERATIONAL.
NO WORK THIS AREA
TO BE REMOVED
65'-0" +/-
FIELD VERIFY
9 NO HANGAR DOOR WORK BEYOND END OF MOTOR
OPERATOR.
1 APPROXIMATE OUTLINE OF FIRE RESPONSE VEHICLES.
2 REMOVED FLOOR MOUNTED BEAM, AND ASSOCIATED
ANCHOR, PATCH AND REPAIR CONCRETE TO MATCH EXISTING.
1/8"=1'-0"
1 1 1
+/-11" 16'-0" +/-7'-1" 16'-0" +/-7'-1" 16'-0"
+/-11"
A801
A801
A801
+\-64'-0"
3 APPROXIMATE AREA OF BAY 4 SHARED DOOR OPERATING
SYSTEM, FLOOR TO CEILING. BAY 4 TO REMAIN FULLY
OPERATIONAL.
SIM.
FRAME
FINISH
DOOR
NO.
DOOR
MATERIAL
DOOR
FINISH
FRAME
MATERIAL GLAZING HARD
WARE REMARKS
DOOR SCHEDULE
DOOR
DIMENSION
FF FACTORY FINISH
HM HOLLOW METAL
IHM INSULATED HOLLOW METAL
INS INSULATED GLASS
INT INSULATED TEMPERED GLASS
MFSTD MANUFACTURER'S STANDARD
PT PAINT
DOOR SCHEDULE ABBREVIATIONS
FF FFH103.2 16'-0" X 16'-0"
H103.3 16'-0" X 16'-0"
MFSTD
MFSTD
INS
DOOR SCHEDULE GENERAL NOTES
1. CONTRACTOR RESPONSIBLE FOR COORDINATING ROUGH
OPENING AND SHIM SPACE.
2. VERIFY THROAT DEPTH AT ALL LOCATIONS.
3. SEE A801 FOR DOOR ELEVATION.
H103.4 16'-0" X 16'-0" -MFSTD
MFSTD MFSTD
IHMPT PTH103.1 3'-0" X 7'-0" HW-1INSIHM --
FF FF INSMFSTD MFSTD
FF FF INSMFSTD MFSTD
HARDWARE
3 HINGES
1 LOCK (STORE ROOM)
1 CLOSER
1 KICKPLATE (32" X 32")
1 PERIMETER SEALS
1 DOOR SWEEPS
1 THRESHOLD - THERMALLY BROKEN
1 OVERHEAD STOP
A801
NO WORK THIS AREA
1/2"=1'-0"
'-0
FI
E
LD
V
E R
IF
Y
WALL ASSEMBLY, TYPICAL:
CORRUGATED METAL SIDING
- MATCH EXISTING SIDING
PROFILE, THICKNESS, AND
FINISH.
5" EPS INSULATION (2
LAYERS MINIMUM) (R=20.85)
WEATHER BARRIER.
EXTERIOR SHEATHING
BOARD.
800S162-54 METAL STUDS AT
16" OC.
BATT INSULATION (R=21)
CORRUGATED METAL SIDING
- MATCH EXISTING SIDING
PROFILE, THICKNESS, AND
FINISH.
ESTIMATED EFFECTIVE
R-VALUE = 31.
'-0
1/2"=1'-0"
A801
A801
A801
A801
WALL ASSEMBLY, TYPICAL:
SEE 1/A401
A801 A801
EXISTING WALL ASSEMBLY, TYPICAL:
CORRUGATED METAL SIDING
SPRAY INSULATION
STRUCTURAL STEEL
FIRE PROOFING
CORRUGATED METAL SIDING
OR EXPOSED FIRE PROOFING
EXISTING WALL ASSEMBLY
SEE 1/A401
A801
MOTOR AND TRACK SUPPORTS, SEE
7/S201
1"=1'-0"
1/2"=1'-0"
3"=1'-0"
1"=1'-0"
1"=1'-0"
1"=1'-0"
1"=1'-0"
3"=1'-0"
3'-0"
6 1/2" 6 1/2"
1/
4" 1'
-1 1"
A801
A801
A801
2'-8"
2' -8
S
STATEMENT OF SPECIAL INSPECTIONS
100% VISUAL INSPECTION FOR SCREW ATTACHMENT, BOLTING AND
ANCHORING OF COLD-FORMED STEEL STUD SHEAR WALLS
THE FOLLOWING STRUCTURAL ITEMS REQUIRE SPECIAL INSPECTION PER IBC SECTION 1704. THESE INSPECTIONS SHALL BE PERFORMED BY A SPECIAL INSPECTOR APPROVED BY THE CONTRACTING OFFICER TO PERFORM THE TYPES OF INSPECTIONS SPECIFIED. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS FOR INSPECTION AND
TESTING THAT ARE NOT PART OF SPECIAL INSPECTIONS.
COLD-FORMED STEEL
FRAMING
B.
1. MATERIAL USED TO MANUFACTURE COLD-FORMED METAL FRAMING SHALL MEET THE MINIMUM REQUIREMENTS OF ASTM C955, GRADE 50 (Fy = 50 KSI) FOR 54 & 68 MIL (14 & 16 GAUGE) AND ASTM C955, GRADE 33 (Fy = 33 KSI) FOR 43 MIL (18 GAUGE) AND
LIGHTER.
2. ALL STRUCTURAL MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS," LATEST EDITION WITH SUPPLEMENTS
3. ACCESSORIES: PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT NECESSARILY LIMITED TO, TRACKS, CLIPS, WEB STIFFENERS, BRIDGING, ANCHORS, FASTENING DEVICES, RESILIENT CLIPS, AND OTHER ACCESSORIES REQUIRED FOR A COMPLETE AND
PROPER INSTALLATION AND AS RECOMMENDED BY THE MANUFACTURER FOR THE STEEL MEMBER.
4. WHERE WALL STUDS DO NOT HAVE WALLBOARD OR PLYWOOD FASTENED TO BOTH FLANGES, INSTALL BRIDGING AS
RECOMMENDED BY MANUFACTURER.
5. FASTENING OF COMPONENTS SHALL BE WITH SELF-DRILLING SCREWS. SCREWS SHALL BE OF SUFFICIENT SIZE TO ENSURE THE STRENGTH OF THE CONNECTION. WIRE TYING OF COMPONENTS SHALL NOT BE PERMITTED. SCREW FASTENERS TO TREATED
WOOD SHALL BE STAINLESS STEEL.
A.
1. BUILDING CODE....................................................................................... 2012 IBC (INTERNATIONAL BUILDING CODE) GOVERNING JURISDICTION................................................................. EIELSON AFB CONTRACTING OFFICER
2. LIVE LOADS:
FLOOR LIVE LOAD (BASIC).............................................................. 50 PSF FLOOR LIVE LOAD (HS20)............................................................... 16,000 LB CONCENTRATED ROOF LIVE LOAD............................................................................. 20 PSF
3. SNOW LOADS:
GROUND SNOW LOAD Pg................................................................ 70 PSF FLAT ROOF SNOW LOAD Pf............................................................ 53 PSF SNOW EXPOSURE FACTOR Ce....................................................... 0.90
SNOW LOAD IMPORTANCE FACTOR I............................................ 1.2
THERMAL FACTOR Ct...................................................................... 1.0
4. WIND LOADS:
BASIC WIND SPEED......................................................................... 115 MPH (3 SECOND GUST)
BUILDING OCCUPANCY CATEGORY.............................................. IV
EXPOSURE......................................................................................... C
INTERNAL PRESSURE COEFFICIENT.............................................. 0.18
COMPONENTS AND CLADDING DESIGN PRESSURE, ZONE 4..... 20.8 PSF
5. SEISMIC LOADS:
SS....................................................................................................... 0.967 S1........................................................................................................ 0.377 SDS...................................................................................................... 0.72 SD1...................................................................................................... 0.41 SOIL SITE CLASS............................................................................... D SEISMIC DESIGN CATEGORY.......................................................... D IMPORTANCE FACTOR..................................................................... 1.5 BASIC SEISMIC FORCE RESISTING SYSTEM................................. LIGHT FRAMED WALLS USING WOOD STRUCTURAL PANELS
RATED FOR SHEAR OR STEEL SHEETS.
R......................................................................................................... 6.5 CS....................................................................................................... . 0.17 DESIGN BASE SHEAR........................................................................ 0.17W ANALYSIS PROCEDURE..................................................................... EQUIVALENT LATERAL FORCE METHOD
GENERAL STRUCTURAL NOTES
& AND
@ AT
AB ANCHOR BOLT
ABV ABOVE
ADJ ADJUSTABLE, ADJUST
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
AHR ANCHOR, ANCHORAGE
APPROX APPROXIMATE
ARCH ARCHITECTURE, ARCHITECTURAL
ASTM AMERICAN SOCIETY OF TESTING AND
MATERIALS
BC BOLT CIRCLE
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BLW BELOW
BM BEAM
BOT BOTTOM
BO BOTTOM OF
BP BASE PLATE
BRG BEARING
BSMT BASEMENT
BTWN BETWEEN
C CHANNEL SECTION
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CON JT CONSTRUCTION JOINT
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUOUS, CONTINUED
CONTR CONTRACTOR
COORD COORDINATE
CP COMPLETE PENETRATION
CTR CENTER
CTSK COUNTERSUNK
DB DIAPHRAGM BOUNDARY
DBL DOUBLE
DEMO DEMOLITION
DIA DIAMETER
DIAG DIAGONAL
DICA DRILLED-IN-CONCRETE ANCHOR
DIM DIMENSION
DIMA DRILLED-IN-MASONRY ANCHOR
DL DEAD LOAD
DN DOWN
DO DITTO
DET DETAIL
DWG DRAWING
(E) EXISTING
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
ELEC ELECTRICAL, ELECTRIC
EL ELEVATION
ENGR ENGINEER
EOC EDGE OF CONCRETE
EQ EQUAL, EARTHQUAKE
EQUIP EQUIPMENT
EXP EXPANSION
EXT EXTERIOR
EW EACH WAY
FB FLAT BAR
FD FLOOR DRAIN
FDN FOUNDATION
FF FINISHED FLOOR
FIN FLR FINISH FLOOR
FO FACE OF
FOBM FACE OF BEAM
FOC FACE OF CONCRETE
FOS FACE OF STEEL
FRMG FRAMING
FS FAR SIDE
FT OR ' FOOT OR FEET
FTG FOOTING
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GLB GLUE LAMINATED BEAM
GR GRADE
GSN GENERAL STRUCTURAL NOTES
GWB GYPSUM WALLBOARD
HLDN HOLD-DOWN
HGALV HOT-DIP GALVANIZED
HDR HEADER
HORIZ HORIZONTAL
HGT HEIGHT
HSL HORIZONTAL LONG SLOTTED HOLES
IAW IN ACCORDANCE WITH
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IN OR " INCH
INCL INCLUDE
INSUL INSULATION, INSULATE
INT INTERIOR
INTMD INTERMEDIATE
JST JOIST
JT JOINT
K KIPS
KSI KIPS PER SQUARE INCH
L ANGLE
LG LONG, LENGTH
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LOC LOCATION
LONG LONGITUDINAL
MATL MATERIAL
MAX MAXIMUM
MC MOMENT CONNECTION, MISC.
CHANNEL
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MH MANHOLE
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MTD MOUNTED
MTL METAL
(N) NEW
NFS NON-FROST-SUSCEPTIBLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OSB ORIENTED STRAND BOARD
PRL PARALLEL
PCC PRE-CAST CONCRETE
PEJ PRE-MOLDED EXPANSION JOINT
PERIM PERIMETER
PERP PERPENDICULAR
PL PLATE
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT, PRESSURE TREATED
QTY QUANTITY
R RADIUS, REACTION
REF REFERENCE, REFER
REINF REINFORCED
REQD REQUIRED
REV REVISION
RMV REMOVE
RM ROOM
RO ROUGH OPENING
SCHED SCHEDULE
SECT SECTION
SH PL SHEAR PLATE
SH SHEET
SIM SIMILAR
SL SNOW LOAD
SLP SLOPE
SOG SLAB-ON-GRADE
SPCG SPACING
SPEC SPECIFICATION
SQ SQUARE
SSH SHORT SLOTTED HOLE
SST STAINLESS STEEL
STD STANDARD
STFNR STIFFENER
STL STEEL
STOR STORAGE
STRUCT STRUCTURE, STRUCTURAL
SYMM SYMMETRICAL
T TOP
TEMP TEMPORARY
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
THK THICK, THICKNESS
THRU THROUGH
TO TOP OF
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOD TOP OF DECK
TOS TOP OF STEEL
TOW TOP OF WALL
TRANSV TRANSVERSE
TS TUBE STEEL
TSW TOP SEAM WELD
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VERIF VERIFY
VSL VERTICAL SLOTTED HOLE
W/ WITH
W/O WITHOUT
W WIDE FLANGE, WIDE, WIDTH
WD WOOD
WHS WELDED HEADED STUD
WJ WALL JOINT
WP WORK POINT, WATER
PROOFING
WWR WELDED WIRE
REINFORCEMENT
S001
BUILDING LAYOUT
NOT TO SCALE
S100
S100
DEMO EXISTING SHEAVES AND CABLES
EXISTING GUIDES TO REMAIN. DO
NOT DAMAGE GUIDES DURING
DEMO AND CONSTRUCTION.
EXISTING HORIZONTAL AND VERTICAL BRACES TO
REMAIN. DO NOT DAMAGE BRACES DURING DEMO
AND CONSTRUCTION.
EXISTING ROOF STRUCTURE TO REMAIN.
INCLUDES BEAMS, PURLINS, DECKING,
ROOFING AND ALL CONNECTIONS THEREOF.
DO NOT DAMAGE ROOF STRUCTURE DURING
DEMO AND CONSTRUCTION
DEMO EXISTING OVERHEAD DOOR.
DEMO EXISTING MOTOR, SHEAVES,
CABLES, COUNTERWEIGHT, AND
ASSOCIATED HARDWARE, EXCEPT AS
NOTED IN DETAIL 3.
S100
EDGE OF OPENING
IN EXISTING WALL
EXISTING CONDUIT
TO REMAIN.
EXISTING SHEAVE
FOR ADJACENT BAY
DOOR TO REMAIN.
EXISTING RAILS FOR
SHEAVES IN BOTH
BAYS TO REMAIN.
DEMO EXISTING SHEAVE IF
DEMO DOES NOT DAMAGE
OR INTERFERE WITH
ADJACENT BAY.
EXISTING SUPPORT
ANGLES TO REMAIN,
BOTH BAYS.
DEMO EXISTING
SHEAVE ASSEMBLY IF
DEMO DOES NOT
DAMAGE OR
INTERFERE WITH
ADJACENT BAY.
EXISTING SHEAVE
ASSEMBLY IN ADJACENT
BAY TO REMAIN.
EXISTING SUPPORT TO
REMAIN, BOTH BAYS.
CABLES NOT SHOWN FOR CLARITY.
DEMO CABLES IN BAY 3. CABLES IN
ADJACENT BAY TO REMAIN.
EDGE OF DOOR
OPENING BELOW.
S
S100
STRUCTURAL DEMOLITION PLAN, BAY 3
NO SCALE
S100
STRUCTURAL DEMOLITION ELEVATION
NO SCALE
S100
STRUCTURAL DEMOLITION AT SHARED CONNECTION
ISOMETRIC
GENERAL NOTES
1. DOOR OPERATION HARDWARE IN BAY 3 AND BAY 4 SHARE STRUCTURAL SUPPORT ELEMENTS. DOOR
IN BAY 4 MUST REMAIN FUNCTIONAL DURING DEMOLITION AND CONSTRUCTION, AND PERMANENTLY THEREAFTER. DO NOT REMOVE ANY HARDWARE WHICH WILL INTERFERE WITH THE OPERATION OF
THE DOOR IN BAY 4. SEE DETAIL 3 FOR ADDITIONAL INFORMATION.
PHOTOGRAPH OF SHARED DOOR HARDWARE AT BAY 4
PHOTOGRAPH OF SHARED DOOR HARDWARE AT BAY 4
DOUBLE JACK STUD
AT EACH END OF
EACH OVERHEAD
DOOR OPENING
BOX HEADER AT
OVERHEAD DOOR,
SEE 1/S201
800T200-54 (50 KSI) TOP TRACK. SECURE TO
UNDERSIDE OF EXISTING OPENING PER 4/S201.
FULL HEIGHT STUDS TO BE
BACK-TO-BACK 800S162-54 (50 KSI) COLD
FORMED STEEL STUDS AT 16" O.C.
SPLICE STUDS PER 3/S201.
TOP OF EXISTING WALL
EXISTING FLOOR SLAB
SINGLE END STUD. SECURE
TO EXISTING WALL
OPENING FRAMING PER
5/S201. EXISTING OPENING
FRAMING IS LIGHT GAUGE
STEEL OR STRUCTURAL
STEEL ANGLE.
SECURE STUDS TO TRACK
AT HEADERS WITH #8
SELF TAPPING SCREWS
THROUGH EACH FLANGE
OF EACH STUD
800T200-54 (50KSI) BOTTOM TRACK. ANCHOR TO
EXISTING FLOOR SLAB WITH 0.145" DIA X 1 1/4" LONG
POWDER ACTUATED FASTENERS AT MAX 32" O.C., BUT
NO LESS THAN 2 FASTENERS PER WALL SEGMENT
BETWEEN OPENINGS. INSTALL ONE FASTENER WITHIN
6" OF EACH END OF EACH OPENING. INSTALL SILL
SEALER PER SPECIFICATIONS.
STUDS ABOVE OVERHEAD DOORS TO BE SINGLE
800S162-54 (50 KSI) COLD FORMED STEEL STUDS AT
16" O.C.
APPROX 64'-0", FIELD VERIFY
A P
P R
O X
5'
-0
FI
E
LD
V
E R
IF
Y1
S201
BOX HEADER AT
PERSONNEL DOOR
PER 2/S201.
S201
STUDS ABOVE PERSONNEL DOOR TO BE
DOUBLE 800S162-54 (50 KSI) COLD
FORMED STEEL STUDS AT 16" O.C. MAX.
SECURE STUDS TO BOTTOM TRACK
WITH #8 SELF TAPPING SCREWS
THROUGH EACH FLANGE OF EACH STUD.
SECURE STUDS TO TOP
TRACK WITH #8 SELF
TAPPING SCREWS
THROUGH EACH FLANGE
OF EACH STUD
S201
10 1/2" 16'-1" 7'-0" 16'-1" 1'-11 1/2" 3'-1" 1'-11 1/2" 16'-1" 10 1/2"
S201
S201
S201
SIM
TYP
S
S200
INFILL WALL FRAMING, BAY 3
NOT TO SCALE
GENERAL NOTES
DIMENSIONS SHOWN ARE APPROXIMATE. COORDINATE
DOOR ROUGH OPENING DIMENSIONS WITH DOOR
MANUFACTURER'S SUBMITTAL INFORMATION SHEETS.
SEE A201 FOR DESIGN DOOR SIZES.
800T200-54 (50 KSI)
BOTTOM TRACK
800T200-54 (50 KSI) TRACK.
TOP FLANGES ORIENTED TO
ACCEPT WALL STUDS.
WALL STUDS
INSULATE BOX HEADER CAVITY
BEFORE INSTALLING TOP TRACK.
FOUR 800S162-54 (50 KSI) STUD SECTIONS.
FASTEN TOP AND BOTTOM TRACK TO FLANGES
OF EACH SECTION WITH # 8 SELF TAPPING
SCREWS AT MAX 12" O.C. STAGGER
PLACEMENT OF FASTENERS HORIZONTALLY.
TWO 800S162-54 (50
KSI) SECTIONS TO
FORM BOX HEADER.
800T200-54 (50 KSI)
BOTTOM TRACK
800T200-54 (50 KSI) TRACK.
TOP FLANGES ORIENTED TO
ACCEPT WALL STUDS.
WALL STUDS
INSULATE BOX HEADER CAVITY
BEFORE INSTALLING TOP TRACK.
4' -0
" M
IN
B E
TW
EE
N S
P
LI
C E
P O
IN
TS
SPLICE STUD AS NEEDED TO
ACHIEVE REQUIRED HEIGHT.
CONTRACTOR TO USE MINIMUM
NECESSARY SPLICES. DO NOT
SPLICE WITHIN 6 FEET OF TOP
OR BOTTOM OF WALL.
A
A
3" T
Y P
V E
R T
2 5/8" TYP
HORIZ
1/
2" C
LR
TO
E D
G E
NINE #8 SELF
TAPPING SCREWS,
EACH SIDE OF
SPLICE, TYP.
EXISTING HEADER.
OUTSIDE FACE OF
EXISTING WALL.
WALL ASSEMBLY PER A 401.
STRUCTURAL WALL TOP
TRACK. FASTEN TO EXISTING
HEADER WITH #8 SELF
TAPPING SCREWS AT 8" O.C.
PRE-DRILL PILOT HOLES INTO
STRUCTURAL STEEL HEADER.
3" X5" 16 GAUGE ANGLE, FULL
LENGTH OF INFILL WALL.
FASTEN TO TOP TRACK AND
EXISTING HEADER WITH #8 SELF
TAPPING SCREWS AT 8" O.C.
PRE-DRILL PILOT HOLES INTO
STRUCTURAL STEEL HEADER.
2"X2"X6" 16 GAUGE
ANGLE CLIP. FASTEN TO
WEB OF KING STUDS AND
HEADER TOP TRACK
WITH FOUR # 8 SELF
TAPPING SCREWS EACH.
2"X2"X6" 16 GAUGE
ANGLE CLIP. FASTEN TO
WEB OF JACK STUD AND
HEADER BOTTOM TRACK
WITH FOUR # 8 SELF
TAPPING SCREWS EACH.
TOP TRACK SECTION AT JACK
STUDS. FASTEN TO HEADER
BOTTOM TRACK WITH FOUR # 8
SELF TAPPING SCREWS.
2" X4"X2" 16 GAUGE ANGLE
CLIPS AT 16" O.C. MAX, FULL
HEIGHT OF INFILL WALL.
FASTEN TO END STUD AND
EXISTING FRAMING WITH ONE
#8 SELF TAPPING SCREW EACH.
EXISTING
EXTERIOR
WALL PANEL
EXISTING WALL
FRAMING
WALL ASSEMBLY PER A401
INFILL WALL
END STUD
KING STUD PER 1/S200
DOUBLE JACK STUD PER 1/S200. FILL
CAVITY WITH INSULATION PRIOR TO
INSTALLING SECOND STUD.
ORIENT SECOND JACK STUD
SO THAT WEB IS FLUSH
WITH EDGE OF EXTERIOR
WALL ASSEMBLY.
1/8" CABLE BRACE AT 45°, TYP
FOUR PER MOTOR IN FOUR
ORTHOGONAL DIRECTIONS.
FASTEN AT BOTH ENDS WITH
CABLE BRACE END
CONNECTORS, MASON SSB-1,
MASON SCBH-1, OR EQUAL.
1 5/8" CHANNEL STRUT, TYP
TWO AT EACH MOTOR
LOCATION.
1/4" DIA ALL THREAD ROD WITH
ROD STIFFENERS, TYP FOUR AT
EACH MOTOR LOCATION
CONTINUOUS 1 5/8" CHANNEL
STRUT. ATTACH TO EACH
EXISTING CURVED BEAM WITH
1/4" DIA BOLTS THROUGH
BOTTOM FLANGE.
OVERHEAD DOOR MOTOR, TYP ONE PER DOOR.
OVERHEAD DOOR
TRACKS, INSTALL PER
MANUFACTURER'S
INSTRUCTIONS.
OVERHEAD DOOR TRACK
SUPPORT. 1 5/8" CHANNEL
STRUT AT BENT BEAM AND
DOOR TRACK WITH 1/4" DIA
ALL THREAD ROD WITH ROD
STIFFENER. SPACE 4' O.C.
MAX, BUT NO LESS THAN
THREE PER DOOR TRACK.
EXISTING BENT BEAM
S
S201
BOX HEADER AT OVERHEAD DOORS
NOT TO SCALE
S201
BOX HEADER AT PERSONNEL DOOR
NOT TO SCALE
S201
TYPICAL STUD SPLICE DETAIL
NOT TO SCALE
S201
WALL TRACK CONNECTION TO EXISTING HEADER
NOT TO SCALE
S201
STUDS AT OVERHEAD DOOR AND EXISTING WALL
NOT TO SCALE
S201
TYPICAL BOX HEADER END CONNECTION
NOT TO SCALE
S201
OVERHEAD DOOR MOTOR AND TRACK SUPPORT
NOT TO SCALE
E100
DEMOLITION PLAN
1/16"=1'-0"
E100
ELECTRICAL POWER PLAN
1/16"=1'-0"
E
100SPECIFIC NOTES
GENERAL SHEET E100 NOTES
| G000 |
| G001 |
| G002 |
| H100 |
| A001 |
| A101 |
| A201 |
| A401 |
| A801 |
| S001 |
| S100 |
| S200 |
| S201 |
| E100 |