MDVL212109 Replace AHU at Supply Bldg 705 Plans.pdf

PDF 639 KB Posted

Attached to
MDVL212109 - Replace Air Handling Unit at Supply Bldg. 705
Solicitation number
W50S7J21B0005
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT SITE

22nd AVE

N

EW

EL

L

R O

A D

8th ST

MERIDIAN

B O

U N D

S

RD

TH

A V

EN

U E

PO

PL

A R

14th ST

A V E th rd

A V E

S

PG

S

DR

NORTH HILLS ST

WINDMILL

DRIVE

LINDELY

ROAD

NE INDUST.

MARION

RD.PARK

PROJECT SITE

152151

807 808

505 506

303 501 rEplacE aIr HaNDlEr uNIT aT baSE Supply blDg 705 pN mDvl212109

186TH aIr rEFuElINg wINg mISSISSIppI aIr NaTIoNal guarD

KEy FIElD aNgb mErIDIaN, mS

JuNE 2021

PROJECT AREA

BLDG 705 - BASE SUPPLY FACILITY

SHEET INDEX

T1.0 covEr SHEET D1.0 EXISTINg coNDITIoN-DEmo plaN a1.0 Floor & powEr plaN a1.1 rEFlEcTED cEIlINg & lIgHTINg plaN m1.0 mEcHaNIcal plaN rEFErENcES:

aNg ENgINEErINg TEcHNIcal lETTEr (Tab D) 15-01 coNTracTINg oFFIcEr 186 arw coNTracTINg oFFIcE mSgT NED mccormIcK 6225 m STrEET mErIDIaN, mS 39307 601-484-9860

NoTE: all rEQuESTS For INFormaTIoN aND maTErIal SubmITTalS SHall bE rouTED THrougH THE baSE coNTracTINg oFFIcE.

baSE cIvIl ENgINEEr 186 cIvIl ENgINEEr SQuaDroN lT col vaugHN THrEaTT 6225 m STrEET mErIDIaN, mS 39307 601-484-9808 proJEcT TEam:

AutoCAD SHX Text o

AutoCAD SHX Text p

AutoCAD SHX Text p

AutoCAD SHX Text l

AutoCAD SHX Text o

AutoCAD SHX Text l

AutoCAD SHX Text p

AutoCAD SHX Text 186th CIVIL ENGINEER SQUADRON

AutoCAD SHX Text

OFFICE OF THE BASE CIVIL ENGINEER

AutoCAD SHX Text

PREPARED BY

AutoCAD SHX Text

MERIDIAN, MISSISSIPPI

AutoCAD SHX Text

AIR NATIONAL GUARD BASE

AutoCAD SHX Text

KEY FIELD

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

PRIME

AutoCAD SHX Text

BEEF

AutoCAD SHX Text U

AutoCAD SHX Text A

AutoCAD SHX Text S

AutoCAD SHX Text G

AutoCAD SHX Text N

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text V

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text T1.0

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

MISSISSIPPI AIR NATIONAL GUARD

AutoCAD SHX Text

DATE:

AutoCAD SHX Text 186th AIR REFUELING WING

AutoCAD SHX Text

27 MAY 2021

AutoCAD SHX Text

REPLACE AIR HANDLER UNIT AT BASE SUPPLY BLDG 705

MECHANICAL

SARC

WDPH

JAG

PARALEGAL

CHAPLAIN

CHAPLAIN

132A

CHAPLAIN

STORAGE

AUDIO/VISUAL

(Not in Contract)

STORAGE

(Not in Contract)

Existing AHU Closet

Demolish north and east walls

AHU

G S

G R

Circular duct feeding

Rooms 134 and 135

Cap and remove duct from this approximate location to the north

Demolish & cap existing gas lines at this approximate location

LEGEND

WALL DEMO REQ'D

HVAC SUPPLY (EXIST)

HVAC RETURN (EXIST)

C O

R R

I D

O R

GENERAL NOTES:

1. THIS PROJECT AFFECTS EXISTING ROOM NUMBERS 129 THROUGH 135. WORK WILL BE REQUIRED IN

ROOM 136 AS REQUIRED FOR ELECTRICAL AND MECHANICAL IMPROVEMENTS. REFER TO SHEET A1.0

FOR LIMITS OF IMPROVEMENTS IN EACH SPACE.

2. DEMOLISH ALL EXISTING HVAC FEATURES WITHIN THE PROJECT LIMITS TO INCLUDE ALL

GRILLS/DIFFUSERS, DUCT, THERMOSTATS, AIR HANDLER, AND MISCELLANEOUS EQUIPMENT, UNLESS

SPECIFICALLY NOTED OTHERWISE. CAP ANY 'IN-USE' DUCT AS NECESSARY. REFER TO SHEET M1.0 FOR

MORE INFORMATION.

3. AN EXISTING FALSE CEILING (PARTIALLY FINISHED GYPSUM) EXISTS APPROXIMATELY 20" ABOVE ACT IN

MOST AREAS. NEW HVAC SYSTEM INSTALLATION MUST BE COMPATIBLE WITHIN THIS INTERSTITIAL

SPACE. ANY MODIFICATIONS TO ACCOMMODATE NEW CONSTRUCTION WILL BE THE RESPONSIBILITY

OF THE CONTRACTOR.

4. ALL CEILING GRID AND LIGHT FIXTURES SHALL BE REMOVED DURING DEMOLITION, UNLESS

SPECIFICALLY NOTED OTHERWISE. REFER TO SHEET A1.0 FOR MORE INFORMATION.

5. CONTRACTOR SHALL BE RESPONSIBLE FOR SAFING AND REINSTALLATION OF MASS NOTIFICATION

(MNS), FIRE ALARM DEVICES, AND SPEAKERS IN THE CEILING. ROOMS TO RECEIVE NEW CEILINGS

INCLUDE ROOMS 129, 130, 131, 133, 134, AND 135. ALL OF THESE ROOMS, EXCEPT FOR ROOM 130, INCLUDE 1 MNS DEVICE, 1 FIRE ALARM DEVICE, AND 1 SPEAKER. GOVERNMENT WILL ASSIST WITH

DISCONNECTION AND RECONNECTION OF MNS DEVICES. CONTRACTOR IS RESPONSIBLE FOR ALL

OTHER ASSOCIATED WORK.

6. ELECTRICAL FEATURES (FIXTURES, RECEPTACLES) TO BE DEMOLISHED SHALL BE REMOVED ENTIRELY

(DEVICE, CABLING, CONDUIT, ETC.) BACK TO THE NEAREST JUNCTION BOX. CONTRACTOR MAY REUSE

ELECTRICAL INFRASTRUCTURE FOR INSTALLATION OF NEW LIGHTING WHERE POSSIBLE. NEW

INFRASTRUCTURE MAY UTILIZE MC CABLE TO FIXTURES BUT MAIN CIRCUITS (HOME RUNS) MUST BE

INSTALLED IN EMT CONDUIT.

7. WHERE NEW FLOORING IS PROPOSED (SEE FINISH SCHEDULE - SHEET A1.0), EXISTING FLOORING

SHALL BE REMOVED.

8. ALL ITEMS NOT SPECIFICALLY MENTIONED FOR DEMOLITION BUT REQUIRED FOR CONSTRUCTION OF

THE IMPROVEMENTS FOR THIS PROJECT SHALL BE CONSIDERED INCIDENTAL.

9. CONTRACTOR SHALL PROTECT ALL AREAS OUTSIDE THE SCOPE OF WORK FOR THIS PROJECT.

*See Note 5 regarding existing fixtures located in existing ceiling

Existing 120V

Electrical Subpanel (E)

Existing Floor Drain

Convert to FGCO

Existing Elec Disconnect

Remove and pull conductors

Remove existing gas radiant heaters, cap gas above ceiling

CWR

CWS

G S

G R

Demolish & cap existing chill water lines at this approx location

Existing Steel Column

To Remain

STORAGE

(Not in Contract)

Demolish shelf above doors at this approx location

Existing Window

To Remain

Existing Window

To Remain

PROJECT LIMITS

PROJECT LIMITS

P R

O J E

C T

I M

I T

S

P R

O J E

I M

I T

S

R E

V I S

I O

N D

A T

E D

E S

C R

I P

T I O

N B

Y A

P P

D

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

P R

O J E

N

U M

B E

R

D R

A W

I N

G

P

A T

H

D A

T E

S H

E E

T

D

E S

I G

N A

T I O

N S

H E

E

M

B E

R

S C

A L

E

N

PLAN

NORTH

SCALE:

"=1'

0' 2' 4' 8' 12'

6'-11"

6'-8"

13'-7"

13'-9"

4'-6"

8'-10"

13'-3" 13'-9"

11'-7"

11'-7"

AutoCAD SHX Text

REPLACE AHU AT SUPPLY BLDG 705

AutoCAD SHX Text D1.01.0

AutoCAD SHX Text

EXITSTING CONDITIONS AND DEMOLITION PLAN

AutoCAD SHX Text PREPARED BY OFFICE OF THE BASE CIVIL ENGINEER 186TH CIVIL ENGINEER SQUADRON KEY FIELD MERIDIAN, MS

AutoCAD SHX Text

186TH AIR REFUELING WING MISSISSIPPI AIR NATIONAL GUARD

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

PRIME

AutoCAD SHX Text

BEEF

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Q

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text V

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text H

AutoCAD SHX Text

M:\Base Projects\SRM\MDVL212109 - Replace AHU at Supply Bldg 705\1.2 Work Statement and Plans

MECHANICAL

SARC

WDPH

JAG

PARALEGAL

CHAPLAIN

132A

CHAPLAIN

STORAGE

AUDIO/VISUAL

(Not in Contract)

STORAGE

(Not in Contract)

EXIST CHILLER

SUPPLY

WAREHOUSE

C O

R R

I D

O R

5'-0"

15'-6"

10'-11"

129A

129B

A1.0

A1.0

Existing Steel Column

(paint req'd)

CHAPLAIN

CHAPLAIN

CHAPLAIN

STORAGE

(Not in Contract)

GENERAL NOTES:.

1. ALL ITEMS LISTED IN THE FINISH SCHEDULE SHALL BE ASSUMED "NEW" UNLESS SPECIFICALLY

NOTED OTHERWISE AS "EXIST/EXISTING" OR "NIC/NOT IN CONTRACT."

2. PAINT ALL INTERIOR DOOR AND WINDOW FRAMES (NOT PERIMETER WALLS) IN AND ADJACENT TO

THE PROJECT AREA.

3. NOTE EXISTING WALLPAPER IN ROOMS 131, 133, AND 135. ALL WALLPAPER SHALL BE REMOVED

AND GYPSUM BOARD REPAIRED AS NECESSARY. NOTE EXISTING WAINSCOTING IN ROOMS 134 AND

135. WAINSCOTING SHALL REMAIN AND BE PROTECTED THROUGOUT CONSTRUCTION.

WAINSCOTING WILL NOT BE PAINTED.

4. PROVIDE DUPLEX RECEPTACLES WHERE SHOWN. FOR RECEPTACLES IN EXISTING WALLS,

CONTRACTOR SHALL ROUGH-IN TO EXISTING WALL (CMU WITH LATHING AND GYPSUM).

5. PROVIDE DATA INFRASTRUCTURE WHERE SHOWN. DATA INFRASTRUCTURE INCLUDES DEEP 4"

SQUARE METALLIC BOX WITH 3/4" EMT STUBBED MINIMUM 6" ABOVE ACT. FOR DATA IN EXISTING

WALLS, CONTRACTOR SHALL ROUGH-IN TO EXISTING WALL (CMU WITH LATHING AND GYPSUM).

6. EXISTING POWER AND DATA NOT SHOWN FOR CLARITY.

7. PROVIDE FLOORING TRANSITION WHERE SHOWN.

8. BOTH NEW DOORS SHALL BE 3'0"x6'8" SOLID WOOD VENEER (CLEAR FINISH). HARDWARE PACKAGE

SHALL INCLUDE LEVER OFFICE LOCKSET (KEYED BY CONTRACTOR TO MATCH GOV KEY) AND

HALF-DOME FLOOR STOP.

9. FURNISH NEW RECEPTACLES, SWITCHES, AND COVERS (IVORY) IN ALL EXISTING FIXTURES

THROUGHOUT THE PROJECT AREA.

10. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO BIDDING.

11. CONTRACTOR SHALL PROTECT ALL AREAS OUTSIDE THE SCOPE OF WORK FOR THIS PROJECT.

LEGEND

NEW WALL

NEW DUPLEX RECEPTACLE

NEW COMM/DATA DROP

NEW LIGHT SWITCH

Existing Window

To Remain

Existing Window

To Remain

13'-7"

13'-7"

4'-6"

8'-10"

13'-9"13'-3"

11'-7"

11'-7"

See Note 7

See Note 7

See Note 7

4" (nom) Metal Stud

(non-load bearing)

" Fire Rated

Gypsum Board

NEW WALL DETAIL

R-13 Insulation

(un-faced)

S S

S

See Note 8

N

PLAN

NORTH

R E

V I S

I O

N D

A T

E D

E S

C R

I P

T I O

N B

Y A

P P

D

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

P R

O J E

M

B E

R

D R

A W

I N

G

P

A T

H

D A

T E

S H

E E

T

D

E S

I G

N A

T I O

N S

H E

M

B E

R

S C

A L

E

SCALE:

"=1'

0' 2' 4' 8' 12'

AutoCAD SHX Text M:\Base Projects\SRM\MDVL212109 - Replace AHU at Supply Bldg 705\1.2 Work Statement and Plans

AutoCAD SHX Text

REPLACE AHU AT SUPPLY BLDG 705

AutoCAD SHX Text A1.01.0

AutoCAD SHX Text

FLOOR & POWER PLAN

AutoCAD SHX Text PREPARED BY OFFICE OF THE BASE CIVIL ENGINEER 186TH CIVIL ENGINEER SQUADRON KEY FIELD MERIDIAN, MS

AutoCAD SHX Text

186TH AIR REFUELING WING MISSISSIPPI AIR NATIONAL GUARD

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

PRIME

AutoCAD SHX Text

BEEF

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Q

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text V

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text H

GENERAL NOTES:

1. CONTRACTOR SHALL BE RESPONSIBLE FOR SAFING AND REINSTALLATION OF MASS NOTIFICATION

(MNS), FIRE ALARM DEVICES, AND SPEAKERS IN THE CEILING. ROOMS TO RECEIVE NEW CEILINGS

INCLUDE ROOMS 129, 130, 131, 133, 134, AND 135. ALL OF THESE ROOMS, EXCEPT FOR ROOM 130, INCLUDE 1 MNS DEVICE, 1 FIRE ALARM DEVICE, AND 1 SPEAKER. GOVERNMENT WILL ASSIST WITH

DISCONNECTION AND RECONNECTION OF MNS DEVICES. CONTRACTOR IS RESPONSIBLE FOR ALL

OTHER ASSOCIATED WORK.

2. ELECTRICAL LIGHTING INFRASTRUCTURE (CIRCUITS, CONDUIT, JUNCTION BOXES, ETC) MAY BE

RE-USED TO THE MAXIMUM EXTENT. NEW INFRASTRUCTURE FOR HOME RUNS SHALL BE

CONSTRUCTED WITH EMT, WHILE CIRCUITS TO INDIVIDUAL FIXTURES MAY BE MC CABLE.

3. ALL EXISTING LIGHTING CONTROL CIRCUITS (SWITCHES) WILL REMAIN AS-IS EXCEPT FOR NEW

LIGHTING IN ROOMS 129A AND 129B.

4. CEILING, LIGHTS, AND FLOORING TO REMAIN IN CORRIDOR AND ROOMS 132, 132A. CEILING AND

LIGHTS SHOWN ONLY FOR HVAC PLANNING PURPOSES.

5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO BIDDING.

6. CONTRACTOR SHALL PROTECT ALL AREAS OUTSIDE THE SCOPE OF WORK FOR THIS PROJECT.

132A

X

X

X

X X

E

E

E

E

E

EXIST CHILLER

LEGEND

NEW WALL

NEW HVAC CEILING CASSETTE

2'x4' LIGHT FIXTURE (EXISTING)

2'x4' LIGHT FIXTURE (NEW)

2'x4' LIGHT FIXTURE (NEW-EMERGENCY)

2'x2' LIGHT FIXTURE (NEW)

LIGHT SWITCH (NEW)

129A

129B

X

E

*See Note 4

*See Note 4

*See Note 4

S

S S

N

PLAN

NORTH

R E

V I S

I O

N D

A T

E D

E S

C R

I P

T I O

N B

Y A

P P

D

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

P R

O J E

M

B E

R

D R

A W

I N

G

P

A T

H

D A

T E

S H

E E

T

D

E S

I G

N A

T I O

N S

H E

M

B E

R

S C

A L

E

SCALE:

"=1'

0' 2' 4' 8' 12'

AutoCAD SHX Text M:\Base Projects\SRM\MDVL212109 - Replace AHU at Supply Bldg 705\1.2 Work Statement and Plans

AutoCAD SHX Text

REPLACE AHU AT SUPPLY BLDG 705

AutoCAD SHX Text A1.11.1

AutoCAD SHX Text

REFLECTED CEILING & LIGHTING PLAN

AutoCAD SHX Text PREPARED BY OFFICE OF THE BASE CIVIL ENGINEER 186TH CIVIL ENGINEER SQUADRON KEY FIELD MERIDIAN, MS

AutoCAD SHX Text

186TH AIR REFUELING WING MISSISSIPPI AIR NATIONAL GUARD

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

PRIME

AutoCAD SHX Text

BEEF

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Q

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text V

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text H

132A

LEGEND

HVAC CEILING CASSETTE

` THERMOSTAT

EXIST CHILLER

T

T

T

T

T

T

T

T

OU-1

GENERAL NOTES:

1. PROVIDE BACNET-COMPATIBLE HVAC EQUIPMENT CAPABLE OF FUTURE CONNECTION TO

THE BASE ENERGY MANAGEMENT SYSTEM. CONNECTION TO THE BASE ENERGY

MANAGEMENT SYSTEM IS NOT REQUIRED AS A PART OF THIS PROJECT.

2. OUTDOOR CONDENSER AND ELECTRICAL DISCONNECT SHALL BE LOCATED ON NORTH

SIDE OF BUILDING APPROXIMATELY AS SHOWN. EXACT LOCATION TO BE FIELD-VERIFIED

BY GOVERNMENT PRIOR.

3. CONTRACTOR SHALL CONSTRUCT A METAL SHROUD/CHASE AROUND REFRIGERANT AND

CONDENSATE PIPING ON NORTH SIDE OF BUILDING 705. SHROUD SHALL BE 26 GAUGE

KYNAR COATED (OR APPROVED EQUAL) METAL AND PROVIDE MANUFACTURER'S

STANDARD COLOR PALETTE.

4. CONTRACTOR SHALL PROVIDE MANIFOLD/BRANCH HEADER IN APPROXIMATE LOCATION

SHOWN.

5. CONTRACTOR SHALL INSTALL BRASS BALL VALVES ON EACH LIQUID AND SUCTION

REFRIGERANT LINE ENTERING AND EXITING THE MANIFOLD.

6. ALL ITEMS NOT SPECIFICALLY MENTIONED BUT REQUIRED FOR CONSTRUCTION OF THE

IMPROVEMENTS FOR THIS PROJECT SHALL BE CONSIDERED INCIDENTAL.

7. CONTRACTOR SHALL PROTECT ALL AREAS OUTSIDE THE SCOPE OF WORK FOR THIS

PROJECT.

Approx location of manifold/branch header

129A

129B

T

T

Convert existing floor drain to FGCO

MS-1

MS-1

MS-1

MS-2

MS-2

MS-2

MS-2

MS-2

MS-1

MS-1

N

PLAN

NORTH

R E

V I S

I O

N D

A T

E D

E S

C R

I P

T I O

N B

Y A

P P

D

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

P R

O J E

M

B E

R

D R

A W

I N

G

P

A T

H

D A

T E

S H

E E

T

D

E S

I G

N A

T I O

N S

H E

M

B E

R

S C

A L

E

SCALE:

"=1'

0' 2' 4' 8' 12'

AutoCAD SHX Text M:\Base Projects\SRM\MDVL212109 - Replace AHU at Supply Bldg 705\1.2 Work Statement and Plans

AutoCAD SHX Text

REPLACE AHU AT SUPPLY BLDG 705

AutoCAD SHX Text M1.01.0

AutoCAD SHX Text

MECHANICAL PLAN

AutoCAD SHX Text PREPARED BY OFFICE OF THE BASE CIVIL ENGINEER 186TH CIVIL ENGINEER SQUADRON KEY FIELD MERIDIAN, MS

AutoCAD SHX Text

186TH AIR REFUELING WING MISSISSIPPI AIR NATIONAL GUARD

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

PRIME

AutoCAD SHX Text

BEEF

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Q

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text V

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text H

Sheets and Views
MDVL212109 Replace AHU at Supply Bldg 705-Model
MDVL212109 Replace AHU at Supply Bldg 705-D1.0
MDVL212109 Replace AHU at Supply Bldg 705-A1.0
MDVL212109 Replace AHU at Supply Bldg 705-A1.1
MDVL212109 Replace AHU at Supply Bldg 705-M1.0
MDVL212109 Title Sheet-Model
MDVL212109 Title Sheet-D-1

File details come from the government source that posted it. Updated .